1 Procedure Instruction of program Explosion Pressure - Test Round 2017 Content 1 General Performance Measurand / Characteristic of interest Test Item and Configurations Components Blind flanges prepared in advance Homogeneity and Stability Homogeneity test Stability Configurations of Test Sample EP and measurements Configuration a) Configuration b) Identification Procedure Flowchart for determination of explosion pressure at normal ambient temperature Flowchart for determination of explosion pressure at ambient temperature of - 40 C Boundary / Environmental Conditions Data acquisition and Transmission Records and additional Documentation Additional Instructions Uncertainty of measurement (optional) Data Analysis and Evaluation Reporting Annex Example of filled in templates PTB Working Group Page 1 of 26

2 1 General Performance In the program Explosion Pressure, the quantity selected which is to be compared (measurand of interest), is the explosion pressure (reference pressure). As has already been mentioned in the "Roll Out Paper", the general routine procedure is described by the standard Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures d - IEC , Edition 7.0. The general routine procedure to determine the explosion pressure is described in clause of IEC The measurand of interest is to determine with the Test Sample EP for two different configurations (single chamber and combination of both chambers with orifice), two different ambient temperatures (normal temperature and ambient temperature of - 40 C) and two different explosive mixtures (ethylene & hydrogen) selected according to IEC On the basis of two configurations of the Test Sample EP, two explosive mixtures, two ambient temperatures and five ignitions each, a total of 40 explosion tests must be performed by each participant for the program Explosion Pressure. The workload to perform this program is approximately three working days. 2 Measurand / Characteristic of interest The measurand of interest is the explosion pressure (reference pressure). This is the quantity selected which is to be compared in the program. 3 Test Item and Configurations To ensure comparability and homogeneity, all Test Samples EP are completely developed and prepared by the coordinator. Every participating laboratory of the program Explosion Pressure will receive all components of the Test Sample EP directly from the coordinator which are needed to perform the program. Please notice that the Test Sample EP which is used in this Test Round 2017 is identical to the test sample which was used in the previous Test Round 2010 of program Explosion Pressure and is almost identical to the test sample which was used in the previous program Flame Transmission - Test Round Participating laboratories which already possess the Test Sample EP or FT shall use it again for this Test Round The required orifice and new gaskets to perform this test round are provided by the coordinator. PTB Working Group Page 2 of 26

3 3.1 Components The Test Sample EP (see Figure 1) consists of two cylindrical compartments of different lengths as well as an orifice. Additionally, two blank flanges are included, each equipped with five test holes of different thread forms. The test sample is composed of 75 single components. Table 1: List of components of Test Sample EP No. Component description Quantity 1 Pipe A (1 x pipe section including 2 x connecting flanges with a total length of mm) (Material: F304L; stainless steel) 2 Pipe B (1 x pipe section including 2 x connecting flanges with a total length of mm) (Material: F304L; stainless steel) 3 Blind flanges with connection holes (Material: F304L; stainless steel) x connecting screws + 24 x nuts (hexagon screws M20, length 80 mm) 48 (Material: A2; steel) 5 Flange gasket (Material: aramid fiber with nitrile rubber) x locking screws + 8 x sealing rings 16 (2 x M 10 x 1; 2 x M 14x 1.25; 2 x G 1/2" A; 2 x G 3/8" A) (Material screws: A2; steel; Material sealing rings: copper) 7 Orifice (ø = 220 mm, material thickness: 6 mm) (Material: duraluminium) 1 Total 75 Figure 1: Exploded view of Test Sample EP PTB Working Group Page 3 of 26

4 3.1.1 Blind flanges prepared in advance The blind flanges located at the pipe ends are equipped with five connection holes of different thread forms. The respective installation holes are used depending on the installation technology. The hole for the pressure sensor is located in the center position. The other installation holes can be used for the gas supply and the ignition source respective individual installation technology adaptors. In addition to the specified installation holes, the participant can locate a threaded hole on his own at the predefined position (if necessary). Figure 2: Position of installation holes on the blind flanges (located at the pipe ends) (1) Predefined position for an installation hole to be placed by the participant on his own if required (2) Installation hole M 10 x 1 (3) Installation hole G 1/2" A (4) Installation hole G 3/8" A (5) Installation hole M 14 x 1.25 (6) Hole (M 10 x 1) for installation of the pressure sensor PTB Working Group Page 4 of 26

5 3.2 Homogeneity and Stability To ensure homogeneity and stability in accordance with ISO/IEC 17043, homogeneity tests are carried out for each test sample before sending it to the participants Homogeneity test The homogeneity test consists of a visual check to control the processing of the sample and a linear measurement to control the geometry and dimensions of the respective components. The following parameters have been checked to assure homogeneity: - Visual check - Length of Pipe A (250 ± 2) mm - Length of Pipe B (500 ± 2) mm - Internal diameter of the pipes (161.5 ± 2) mm The tolerances of the parameters have been determined related to preliminary tests performed at PTB. Scattering within the range of tolerance has no measurable influence on the explosion pressure Stability Due to the massive construction of the test sample and the used high-quality materials, long-term stability can be assumed. Furthermore, preliminary investigations and extensive measurement series on the test sample have not caused any changes in the geometry. Therefore, no further special stability test has been performed. 3.3 Configurations of Test Sample EP and measurements The configurations of the Test Sample EP to perform the tests are as follows: Configuration a) Pipe A Five ignition tests with explosive mixture (1) (ethylene 8 % ± 0.5 %) at normal ambient temperature (ignition side 1) Five ignition tests with explosive mixture (2) (hydrogen 31 % ± 1 %) at normal ambient temperature (ignition side 1) Five ignition tests with explosive mixture (1) (ethylene 8 % ± 0.5 %) for use at an ambient temperature of - 40 C (ignition side 1) Five ignition tests with explosive mixture (2) (hydrogen 31 % ± 1 %) for use at an ambient temperature of - 40 C (ignition side 1) Figure 3: Configuration a) PTB Working Group Page 5 of 26

6 3.3.2 Configuration b) Pipe A combined with Pipe B and orifice Five ignition tests with explosive mixture (1) (ethylene 8 % ± 0.5 %) at normal ambient temperature (ignition side 2) Five ignition tests with explosive mixture (2) (hydrogen 31 % ± 1 %) at normal ambient temperature (ignition side 2) Five ignition tests with explosive mixture (1) (ethylene 8 % ± 0.5 %) for use at an ambient temperature of - 40 C (ignition side 2) Five ignition tests with explosive mixture (2) (hydrogen 31 % ± 1 %) for use at an ambient temperature of - 40 C (ignition side 2) 3.4 Identification Figure 4: Configuration b) The two Pipes A and B, the flanges and the orifice of the Test Samples EP are marked with a unique identification number. The identification number is structured depending on the version - as follows: Figure 5: Structure of identification number of Test Sample EP Version Test Round 2010 Figure 6: Structure of identification number of Test Sample EP Version Test Round 2013, Test Sample FT PTB Working Group Page 6 of 26

7 Figure 7: Structure of identification number of Test Sample EP Version Test Round Procedure The program Explosion Pressure - Test Round 2017 is performed on two configurations of the Test Sample EP, two explosive mixtures and two ambient temperatures. To perform the program, the individual routine procedure of each test laboratory needs to be applied (used every day for achieving the test results for real projects). Additionally, detailed guidance how to perform the tests together with the test samples provided in this paper is to be applied. The following program flowcharts show the single steps for the performance of the tests for program Explosion Pressure - Test Round PTB Working Group Page 7 of 26

8 4.1 Flowchart for determination of explosion pressure at normal ambient temperature Start 1. Setting up the configuration (selection a) or b)) 2. Recording the ambient pressure and temperature 13. Rinse test sample with sufficient air 3. Selection and setting up the concentration of the explosive mixture 13. Rinse test sample with sufficient air 4. Filling up the test sample with the explosive mixture 5. Recording the concentration of the explosive mixture No 6. Relief or adjust the explosive mixture to atmospheric pressure 7. Recording the pressure, temperature and humidity of the explosive mixture (if available 8.Ignition No 9. Recording the measurement result (explosion pressure) 10. Have the five measurements been performed with the explosive mixture? Yes 11. Have the ten measurements for the configuration been performed? Yes 12. Photo documentation of the configuration End Figure 8: Flowchart for normal ambient temperature PTB Working Group Page 8 of 26

9 Table 2: Explanations of the flowchart for determination of explosion pressure at normal ambient temperature Step Explanation Note 1 Setting up the selected configuration a) or b). One cycle in the program flowchart always relates to one configuration. 2 The recording of the ambient pressure and temperature of the test facility can be helpful for further analysis of the test results. 3 Selection and setting the concentration of the gas-air mixture in accordance with IEC , section : Explosive mixture: (1) ethylene (8 ± 0.5) % or Explosive mixture: (2) hydrogen (31 ± 1) % 4 Filling up the test sample with the explosive mixture until the specified concentration has been reached. 5 Recording the concentration of the explosive mixture in the test sample. 6 Relief of the explosive mixture overpressure in the test sample and adjust to atmospheric pressure. 7 If available, the recording of the pressure, temperature and humidity of the explosive mixture can be helpful for further analysis of the test results. 8 Trigger ignition device: Ignition on Side 1 for configuration a) or Ignition on Side 2 for configuration b) 9 Recording of the measurement results for the respective configuration (a) or b)) with accompanied uncertainty (if available). In addition, the selected pressure curves shall be recorded. 10 After five measurements for one explosive mixture in the selected configuration have been completed, measurements for the second explosive mixture can be carried out. 11 After the ten measurements (five measurements per explosive mixture) for the selected configuration have been performed, measurements for the next configuration can be carried out. 12 For a complete documentation of the test set-up, photos showing the total set-up as well as the connections used should be taken. 13 To eliminate possible combustion and remaining humidity from previous ignitions, the test sample should be sufficiently purged with air after each ignition. See section 3.3; See Table 1 See section 5.1; Template: Test Record EP See section 3.3; See section 5.1; Template: Test Record EP See section 5.1; Template: Test Record EP See section 3.3; See section 5.1; See Section 9; Template: Test Record EP Start again with step 1 of the program flowchart See section 5.1; Template: Test Setup EP PTB Working Group Page 9 of 26

10 4.2 Flowchart for determination of explosion pressure at ambient temperature of - 40 C Start 1. Setting up the configuration (selection a) or b)) 14. Rinse test sample with sufficient air 2. Selection and setting up the concentration of the explosive mixture 14. Rinse test sample with sufficient air 3. Filling up the test sample with the explosive mixture No Test at 40 C 5a. Cooling down the temperature of the explosive mixture to -40 C 4. Choosing a method for an ambient temperature of -40 C in accordance to Test with increased pressure 5b. Increasing the pressure of the explosive mixture using the formula of Recording the concentration of the explosive mixture 7. Relief or adjust the explosive mixture to atmospheric pressure (only for testing at -40 C) 8. Recording the pressure, temperature and humidity of the explosive mixture (if available No 9.Ignition 10. Recording the measurement results (explosion pressure) 11. Have the five measurements been performed with the explosive mixture? Yes 12. Have the ten measurements for the configuration been performed? Yes 13. Photo documentation of the configuration End Figure 9 Flowchart for ambient temperature of 40 C PTB Working Group Page 10 of 26

11 Table 3 Explanations of the flowchart for determination of explosion pressure at ambient temperature of 40 C Step Explanation Note 1 Setting up the selected configuration a) or b). One cycle in the program flowchart always relates to one configuration. 2 Selection and setting the concentration of the gas-air mixture in accordance with IEC , section : Explosive mixture: (1) ethylene (8 ± 0.5) % or Explosive mixture: (2) hydrogen (31 ± 1) % 3 Filling up the test sample with the explosive mixture until the specified concentration has been reached. 4 The reference pressure for use at ambient pressure of 40 C shall be determined by one of the following methods in accordance to IEC , section : (a) The reference pressure shall be determined at a temperature not higher than the minimum ambient temperature, or (b) the reference pressure shall be determined at normal ambient temperature using the defined test mixture(s), but at increased pressure. 5a Cooling down the temperature of the explosive mixture to 40 C 5b The absolute pressure of the explosive mixture (P), in kpa, shall be calculated by the following formula, using T a, min in C: P = 100[293 / (T a, min + 273)] kpa 6 Recording the concentration of the explosive mixture in the test sample. 7 Relief of the explosive mixture overpressure in the test sample and adjust to atmospheric pressure. (This only applies using the method to determine the reference pressure at an ambient temperature of 40 C.) 8 If available, the recording of the pressure, temperature and humidity of the explosive mixture can be helpful for further analysis of the test results. 9 Trigger ignition device: Ignition on Side 1 for configuration a) or Ignition on Side 2 for configuration b) 10 Recording of the measurement results for the respective configuration (a) or b)) with accompanied uncertainty (if available). In addition, the selected pressure curves shall be recorded. 11 After five measurements for one explosive mixture in the selected configuration have been completed, measurements for the second explosive mixture can be carried out. 12 After the ten measurements (five measurements per explosive mixture) for the selected configuration have been performed, measurements for the next configuration can be carried out. 13 For a complete documentation of the test set-up, photos showing the total set-up as well as the connections used should be taken. 14 To eliminate possible combustion and remaining humidity from previous ignitions, the test sample should be sufficiently purged with air after each ignition. See section 3.3; See Table 1 See section 3.3; See IEC , section ; See section 5.1; Template: Test Record EP See section 5.1; Template: Test Record EP See section 3.3; See section 5.1; See section 9; Template: Test Record EP Start again with step 1 of the program flowchart See section 5.1; Template: Test Setup EP PTB Working Group Page 11 of 26

12 4.3 Boundary / Environmental Conditions The tests shall be performed with the ambience conditions which are to be applied for the individual routine procedure of each laboratory (in accordance with the requirements of IEC ). Due to the relationship between explosion pressure and specific conditions it could be helpful for the analysis of the results to get as much detailed information about the boundary / environmental conditions during the tests as possible. The environmental parameters of interest are ambient pressure and ambient temperature. Further interesting parameters are pressure, temperature and humidity of the explosive mixture inside the sample respectively inside the system. The Test Record EP provides the opportunity to record the mentioned parameters. 5 Data acquisition and Transmission The templates for all data, information and documentation to be recorded are made available in an electronic form on the PTB Ex PTS website. Web address: Menu items: Programs -> Program "Explosion Pressure" (Test Round 2017) -> Download 5.1 Records and additional Documentation There are two documents which are to be completed during the tests, Test Record EP and Test Setup EP. Furthermore, pressure curves shall be recorded. In the document Test Record EP the following values / parameters shall be determined: Ambient temperature Ambient pressure The explosive mixture to be used, in volumetric ratio with air Pressure of explosive mixture Temperature of explosive mixture Humidity of explosive mixture Explosion pressure P 1 (Side 1) with accompanied uncertainty (if available) Explosion pressure P 2 (Side 2) with accompanied uncertainty (if available) In the document Test Setup EP the following information shall be provided: Photos showing the total setup as well as the connections used Photos showing the used measuring system to measure the explosion pressure (pressure transducers, amplifiers, data acquisition device / system, etc.) Photos showing the used system to produce and analyze the explosive mixture Photos showing the method of cooling down the temperature of the explosive mixture to 40 C (if this method has been chosen) PTB Working Group Page 12 of 26

13 As the explosion pressure to be measured shows a dynamic behaviour, it is important to record also pressure curves. It is not necessary to record all pressure curves for each one of the ten ignitions per configuration, but the selection shown in the following should be made at least: For configurations a) and b) at normal ambient temperature, the pressure curve with the highest explosion pressure per explosive mixture must be recorded: 1. Configuration a) -> ethylene -> maximum explosion pressure 2. Configuration a) -> hydrogen -> maximum explosion pressure 3. Configuration b) -> ethylene -> maximum explosion pressure 4. Configuration b) -> hydrogen -> maximum explosion pressure For configurations a) and b) at ambient temperature of - 40 C, the pressure curve with the highest explosion pressure per explosive mixture must be recorded: 5. Configuration a) -> ethylene -> maximum explosion pressure 6. Configuration a) -> hydrogen -> maximum explosion pressure 7. Configuration b) -> ethylene -> maximum explosion pressure 8. Configuration b) -> hydrogen -> maximum explosion pressure The completed templates Test Record EP, Test Setup EP and the pressure curves are to be uploaded on the PTB Ex PTS website ( in the upload area. By this, the documents are forwarded to the coordinator. Menu items: Programs -> "Explosion Pressure" (Test Round 2017) -> Upload 6 Additional Instructions It is very welcomed that a participating laboratory, which has the technical possibilities to perform the tests for an ambient temperature of 40 C with the method of increasing pressure as well as cooling down the temperature of the explosive mixture, perform the tests with both methods. Should that be the case, the results which shall be used for the evaluation in the reports (as the official participants results) must be noted in the comments section of Test Record EP. The transmitted data must be the original data. To get a better understanding for completing the documentation, a model documentation (Test Record EP Example, Test Setup EP Example) with fictional values is enclosed in Annex You can also find them in an electronic form on the website in the download section. (Menu items: Programs -> Program "Explosion Pressure" (Test Round 2017) -> Download) To facilitate the data analysis please upload your Test Record EP in the given *.xls(x) format. The Test Samples EP are provided for the use within the PTB Ex PT Program Explosion Pressure - Test Round It is not intended to use the test samples for other purposes. PTB Working Group Page 13 of 26

14 The Test Sample EP should be kept by the participant after the performance of the tests for future programs. To assure homogeneity, the positions of the two pressure sensors on the flanges are predetermined. The position for pressure sensors S1 and S2 is in the center of the prepared flanges. Participants shall always perform the tests according to the applying standard and the Procedure Instruction for EP. In addition, participants shall perform as they would do in their daily in-house routine. Please take notice of the Best Practice Paper Explosion Pressure 2010 available on the PTB Ex PTS website under: Menu items: Best Practice Papers / QM -> Best Practice Papers -> Best Practice Paper Explosion Pressure Uncertainty of measurement (optional) In accordance to OD 012 of IECEx the measurement of explosion pressure is a test where test method and handling of the results has already taken into account measurement uncertainties by testing under worst case conditions and by application of safety factors. Therefore, it is not necessary to calculate the uncertainty associated with the measurement result. Nevertheless, for the calculation of performance statistics and the evaluation of the performance of a participating laboratory within a proficiency testing scheme, it is forward-looking and fruitful to have a statement about the accompanied uncertainty of the result of a measurement. A first step to get in touch with the topic is to get an overview about the significance and the handling of uncertainty of measurement in the participating laboratories. Therefore, we would like the participants to make uncertainty of measurement calculations for the measured explosion pressures in program Explosion Pressure Test Round As a guide for application of uncertainty of measurement IECEx OD 012 can be used. The Test Record EP provides fields for the values of uncertainty as well as space for a description of the used calculation method and the uncertainty budget. 8 Data Analysis and Evaluation The statistical methods used to analyze and evaluate the participants results are developed and documented in accordance to ISO/IEC and ISO It is documented in the reports and describes in detail the use of descriptive statistics, methods used to determine the assigned value, interpretation of the statistical analysis and criteria for performance evaluation. 9 Reporting Reports are made available electronically in compliance with the requirements of standard ISO/IEC 17043, clause 4.8. Reports include a summary of the results for all participants of the PTB Ex Proficiency Testing Program Explosion Pressure - Test Round 2017 in form of tabular and graphical presentations. Furthermore, the reports include detailed information like a description of the test samples used, a description of the test samples preparation and homogeneity and stability assessment, procedures used to establish the assigned values and information about procedures used to statistically analyze the data. The reporting structure is organized in two parts, an interim report and a final report. After performance of the tests the participating laboratories receive an interim report. They can analyze PTB Working Group Page 14 of 26

15 their results compared with the other laboratories and are invited to repeat the tests in a second phase after improvement of their procedures and instrumentation, if they are not happy with their position regarding the difference with the assigned value. After this second phase with the new uploaded results a final report will be issued. If a participant does not want to take part in the phase II session, the participants data of phase I will be used for the final report of the program. All participants are requested to handle all information and data of the reports confidentially. PTB Working Group Page 15 of 26

16 10 Annex 10.1 Example of filled in templates PTB Working Group Page 16 of 26

17 PTB Working Group Page 17 of 26

18 PTB Working Group Page 18 of 26

19 PTB Working Group Page 19 of 26

20 PTB Working Group Page 20 of 26

21 PTB Working Group Page 21 of 26

22 PTB Working Group Page 22 of 26

23 PTB Working Group Page 23 of 26

24 PTB Working Group Page 24 of 26

25 PTB Working Group Page 25 of 26

26 PTB Working Group Page 26 of 26

Procedure Instruction of program Pressurized Enclosure - Test Round 2017

Procedure Instruction of program Pressurized Enclosure - Test Round 2017 Procedure Instruction of program Pressurized Enclosure - Test Round 2017 Provider: Physikalisch-Technische Bundesanstalt Address: Bundesallee 100 38116 Braunschweig Country: Germany Place, date Braunschweig,

More information

The evolution of the Ex-proof flame path

The evolution of the Ex-proof flame path April 2017 The evolution of the Ex-proof flame path As written in previous dissertation, the most critical part of a flameproof enclosure 'Ex d' is the flame path. Although the Standards are divided into

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:

More information

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities Specific Accreditation Criteria Calibration ISO IEC 17025 Annex Mass and related quantities January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

This test shall be carried out on all vehicles equipped with open type traction batteries.

This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4. Determination of hydrogen emissions page 1 RESS-6-15 5.4.1. This test shall be carried out on all vehicles equipped with open type traction batteries. 5.4.2. The test shall be conducted following

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Conductor Bushings Series 8174

Conductor Bushings Series 8174 > Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The

More information

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Drawing 1 VA Di ZG1 Ex-d Measured variables actual flow rate

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Type Testing Procedure for Crankcase Explosion Relief Valves

Type Testing Procedure for Crankcase Explosion Relief Valves (Jan 2005) (Corr.1 Nov 2005) (Rev.1 Oct 2006) (Corr.1 Mar 2007) (Rev.2 Sept 2007) (Corr.1 Oct 2007) (Rev.3 Jan 2008) Type Testing Procedure for Crankcase Explosion Relief Valves 1. Scope 1.1 To specify

More information

Training for Proofmaster M/S/Automat. Functional principle for airtightness testing

Training for Proofmaster M/S/Automat. Functional principle for airtightness testing Training for Proofmaster M/S/Automat Functional principle for airtightness testing July 2017 Airtightness measurement 1. Measuring principle 2. Behaviour of the watch under vacuum 3. Behaviour of the watch

More information

New Findings for the Application of Systems for Explosion- Isolation with Explosion Venting

New Findings for the Application of Systems for Explosion- Isolation with Explosion Venting 529 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 48, 2016 Guest Editors: Eddy de Rademaeker, Peter Schmelzer Copyright 2016, AIDIC Servizi S.r.l., ISBN 978-88-95608-39-6; ISSN 2283-9216 The

More information

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC Flow measurement Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC WIKA data sheet FL 10.01 Applications Power generation Oil production and refining Water treatment

More information

RTD temperature probes

RTD temperature probes RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) Title: Report from ExMC Working Group 2 - TGDs To: Members

More information

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates Impact of imperfect sealing on the flow measurement of natural gas by orifice plates Rubens Silva Telles 1, Kazuto Kawakita 2 1 IPT Instituto de Pesquisas Tecnológicas, São Paulo, Brazil, rtelles@ipt.br

More information

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item: This ballot covers the following item: API 520 Part I 10 th Edition Ballot Item 2.1 2008 12 Modify guidance to PRV datasheets (Line 17) to assist user s with determining the temperature to use for selecting

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Electronic gas volume corrector model DGVC-04

Electronic gas volume corrector model DGVC-04 Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Vortex Flow Sensor VA Di Ex-d Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Drawing 1 Measurable variables actual flow rate actual

More information

WP2 Fire test for toxicity of fire effluents

WP2 Fire test for toxicity of fire effluents Pagina 3 di 89 TRA SFEU VTT 22.6.2009 v.2 WP2 Fire test for toxicity of fire effluents Task 2.1.2 Development of small-scale test method for fire effluents Step 1: Use of modeling Plans according to DoW:

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION Approved By: Senior Manager: Mpho Phaloane Revised By: Field Manager: Neville Tayler Date of Approval: 2015-08-26 Date of Implementation: 2015-08-26

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof

Pressure/Vacuum Diaphragm Valve PROTEGO UB/SF. deflagration- and endurance burning-proof deflagration- and endurance burning-proof PROTEGO UB/SF 7 Ø b 4 The set pressure is adjusted with a freeze resistant water-glycol mixture, which assures safe operation under extreme cold weather conditions.

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor AUK Environmental Sensor Environmental influences can be compensated in two ways: 1. "Manual" input of the current data for air temperature, humidity and pressure and the material temperature of the testpiece

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information

ANTI-EXPLOSION PANELS

ANTI-EXPLOSION PANELS ANTI-EXPLOSION PANELS ATEX TO AVOID THE FIRE AND EXPLOSION OF THE FILTERS AND SILOS WITH AIRCOM S FIREBREAK SASH SHUTTER AND ANTI-EXPLOSION PANELS CERTIFIED WITH THE NORM UNI EN14797 CERTIFIED 2049 DNV-MUNO

More information

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Hose assemblies Part 1: Dimensions and requirements

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Hose assemblies Part 1: Dimensions and requirements INTERNATIONAL STANDARD ISO 17165-1 First edition 2007-10-15 Hydraulic fluid power Hose assemblies Part 1: Dimensions and requirements Transmissions hydrauliques Flexibles de raccordement Partie 1: Dimensions

More information

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No. IECEx Cert f cate of Gonform ty INTERNATIONAL ELECTROTECHNIGAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.tecex.com Certificate No.

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

UHrasonic Sensor VEGASON60 type series SN6*.CI**H*** Certificate No.: IECEx PTa 06.0099X Issue No.: 0 Status: Current Date of Issue: 2006-12-27 Page 1 of 3 Applicant: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Electrical Apparatus: Optional

More information

Experimental determination of deflagration explosion characteristics of methane air mixture and their verification by advanced numerical simulation

Experimental determination of deflagration explosion characteristics of methane air mixture and their verification by advanced numerical simulation Structures Under Shock and Impact XII 169 Experimental determination of deflagration explosion characteristics of methane air mixture and their verification by advanced numerical simulation M. Mynarz,

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

PRAGMATIC ASSESSMENT OF EXPLOSION RISKS TO THE CONTROL ROOM BUILDING OF A VINYL CHLORIDE PLANT

PRAGMATIC ASSESSMENT OF EXPLOSION RISKS TO THE CONTROL ROOM BUILDING OF A VINYL CHLORIDE PLANT PRAGMATIC ASSESSMENT OF EXPLOSION RISKS TO THE CONTROL ROOM BUILDING OF A VINYL CHLORIDE PLANT L.P. Sluijs 1, B.J. Haitsma 1 and P. Beaufort 2 1 Vectra Group Ltd. 2 Shin-Etsu (contact details: Vectra Group

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Junction Boxes Series 8118

Junction Boxes Series 8118 > Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature

More information

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid INTERNATIONAL STANDARD ISO 23181 First edition 2007-08-15 Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid Transmissions hydrauliques Éléments

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Pressure Equalising Valves Model , for Differential Pressure Gauges

Pressure Equalising Valves Model , for Differential Pressure Gauges Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to

More information

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 750 set range: bar Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long

More information

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications Contents Data Sheet S265 2600T Series Pressure Transmitters Engineered solutions for all applications Wide range of remote seal types Allows optimum design for each application without compromising performance

More information

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

ISO Vacuum gauges Calibration by direct comparison with a reference gauge INTERNATIONAL STANDARD ISO 3567 First edition 2011-12-15 Vacuum gauges Calibration by direct comparison with a reference gauge Manomètres Étalonnage par comparaison directe avec un manomètre de référence

More information

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment The Standard Governing the Storage & Use of Silane: Compressed Gas Association s Publication CGA G-13 2015: Storage

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves INTERNATIONAL STANDARD ISO 21013-1 First edition 2008-06-15 Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves Récipients cryogéniques Dispositifs

More information

Dead-weight tester High-pressure version Model CPB3800HP

Dead-weight tester High-pressure version Model CPB3800HP Calibration Dead-weight tester High-pressure version Model CPB3800HP WIKA data sheet CT 31.07 for further approvals see page 5 Applications Primary standard for calibrating the pressure scale in a hydraulic

More information

DK46 - DK800 Supplementary instructions

DK46 - DK800 Supplementary instructions DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

VACUVENT VE SERIES CATALOGUE

VACUVENT VE SERIES CATALOGUE VACUVENT VE SERIES CATALOGUE October 2018 " ba f wa e " The Triple Function Air Valve Vacuvent offers a tri function air valve that not only breaks vacuum, but also reduces surge on pipeline filling and

More information

Pressure measurement. Pressure gauges

Pressure measurement. Pressure gauges Pressure gauge Pressure measurement There are four types of pressure measurements: Measurement of absolute pressure : Measurements are made with respect to absolute pressure, for example as with atmospheric

More information

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Z, Y, and X PURGE INDICATORS / CONTROLLERS PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories

More information

Models 106-RF / 206-RF Rate of Flow Control Valve

Models 106-RF / 206-RF Rate of Flow Control Valve Rate of Valve KEY FEATURES Accurately limits low to a pre-set maximum Easily adjustable low limit Paddle-style oriice plate included Optional oriice plate housing 106-RF Globe Product Overview The 106-RF

More information

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010) Accessories Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev. 02-12/04/2010) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

PROTEGO Deflagration Flame Arresters. Volume 3. Volume 3. for safety and environment

PROTEGO Deflagration Flame Arresters. Volume 3. Volume 3. for safety and environment PROTEGO Deflagration Flame Arresters Volume 3 Volume 3 Deflagration Flame Arrester Function and description The function of fl ame arresters in the various combustion processes and the location of their

More information

STANDARDS FOR COMPRESSED GAS TESTING

STANDARDS FOR COMPRESSED GAS TESTING STANDARDS FOR COMPRESSED GAS TESTING APPLICATION NOTE HPD-002 (US) Introduction This publication provides excerpts from some of the many guidelines and standards that pertain to compressed gases in cleanrooms.

More information

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH 1 D-K-15143-01-00 Services around the measurement technology in Germanys most accurate DAkkS laboratory*. Whether

More information

Gas Pressure Regulator HON 300

Gas Pressure Regulator HON 300 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction

More information

Recommended Practices for Calibration Laboratories

Recommended Practices for Calibration Laboratories Recommended Practices for Calibration Laboratories May 1999 General This document recommends environmental practices and documentary and operational protocols for calibration laboratories that provide

More information

Ultrasonic Flowmeter USZ 08

Ultrasonic Flowmeter USZ 08 Ultrasonic Flowmeter USZ 08 PRODUCT INFORMATION Reliable Measurement of Gas Fields of application, method of operation and construction 2 Fields of application The ultrasonic flowmeter is an advanced measuring

More information

Technical Information Cleanfit CUA451

Technical Information Cleanfit CUA451 TI00369C/07/EN/13.13 71238305 Products Solutions Services Technical Information Cleanfit CUA451 Manually operated retractable assembly for water, wastewater and process media Application Drinking water

More information

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G) Institut fédéral de métrologie METAS METAS-N001/EN Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T (15 000 G) This document is a translation

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 2 DS-ED 01/2017 - ENG INDEX CHAPTER 1 Safety valves in series 3030 CHAPTER 2 Safety valves in series 3060 CHAPTER 3 Safety valves in series 3061 CHAPTER 4 Safety

More information

FPG8601 Force Balanced Piston Gauge

FPG8601 Force Balanced Piston Gauge FPG8601 Force Balanced Piston Gauge Reference Level Calibration System for very low pressure Pressure range: 0 to 15 kpa gauge, absolute and absolute differential Standard resolution: 0.010 Pa, high resolution

More information

PosiTector UTG, UTG-STD & UTG-ME

PosiTector UTG, UTG-STD & UTG-ME Management Procedure 2585 Revision: E Date Issued: Feb 21, 2003 Date Revised: 14 August 2009 Calibration Procedure DeFelsko Corporation PosiTector UTG, UTG-STD & UTG-ME Ultrasonic Thickness Gage Table

More information

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori Vacuum Saving Valve Series ZP2V Model Selection Select the quantity of vacuum saving valves that can be used with one vacuum generator. Selection Conditions Work piece: No leakage and several sizes Required

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

Vapor Sorption Analyzer

Vapor Sorption Analyzer Vapor Sorption Analyzer Quick Start Guide 1. Getting Started Place the AquaLab VSA on a flat surface. Use the bubble level(figure 1: Adjustment and bubble level) and use the adjustable feet to level the

More information

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968 Supplementary instructions Rod and cable components for VEGAFEX series 80 Document ID: 44968 Contents Contents 1 Product description 1.1 Extensions... 3 2 Mounting 2.1 General instructions... 6 2.2 Rod

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

6-5 Maintenance Manual

6-5 Maintenance Manual Non Return Valve 6-5 Maintenance Manual Contents 1. PRODUCT DESCRIPTION... 1 1.1 How it works... 1 1.2 Overall dimensions... 3 1.3 Technical datasheet... 4 1.3.1 Push flow situation... 4 1.3.2 Pull flow

More information

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx Contents 1 Introducing the Pipette Check application... 3 2 important notes... 3 3 Selecting the

More information

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor INTERNATIONAL STANDARD ISO 15970 First edition 2008-06-15 Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor Gaz naturel Mesurage des caractéristiques

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total

More information

The Use of Porous Structures in Flameproof Enclosures to Reduce the Maximum Explosion Pressure

The Use of Porous Structures in Flameproof Enclosures to Reduce the Maximum Explosion Pressure 607 A publication of VOL. 31, 2013 CHEMICAL ENGINEERING TRANSACTIONS Guest Editors: Eddy De Rademaeker, Bruno Fabiano, Simberto Senni Buratti Copyright 2013, AIDIC Servizi S.r.l., ISBN 978-88-95608-22-8;

More information

Level sensing relative and absolute pressure transmitter type 712

Level sensing relative and absolute pressure transmitter type 712 Level sensing relative and absolute pressure transmitter type 712 Pressure range 0... 0.3-3 bar The level sensing pressure transmitter Type 712 is manufactured using an relative or absolute pressure measuring

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

Gas Absorption Column CAG

Gas Absorption Column CAG Gas Absorption Column CAG Engineering and Technical Teaching Equipment PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION ISO 9001: Quality Management (for Design, Manufacturing, Commercialization and After-sales

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

6-way characterised control valves DN15 / DN 20 / DN 25

6-way characterised control valves DN15 / DN 20 / DN 25 6-way characterised control valves DN15 / DN 20 / DN 25 Table of contents Introduction 2 Project planning 2 Structure of the 6-way characterised control valves 2 Range of use 2 Characteristic curve 3 Flow

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series

More information