Pneumatic Function Fittings Metric & Inch
|
|
- Britton Chandler
- 5 years ago
- Views:
Transcription
1 Metric & nch Sensor Fitting Very compact units asy tube insertion for rapid assembly of pneumatic circuits Positive tube anchorage Simpler pneumatic systems liminates need for electrical reed switches Technical ata Medium: ompressed air Operating : ylinder pressure (Pc) bar max Sensor supply pressure - bar Sensor switch pressure. bar typ. Operating Temperature: to +8 ody Ports mm Push-in Fittings Push-in Fittings 8, SPP anjo olt 8, NPTF anjo olt Tube s mm O/ O/ Tubing Types: Nylon or, polyurethane and other plasticised or unplasticised tubing which conforms to the tolerances specified in S 9, Part, 97, light and normal duty, N 778, N 7, NF 9- Ordering nformation To order, quote appropriate product number from the tables on the following pages. Product numbering system is designed to make identification and selection simple: Series Number Type Shape / Tube Tube / Materials elrin and plastic parts lass filled nylon Nickel plated brass collet Nitrile and polyurethane elastomeric parts Nickel plated brass banjo bolt /97 N/L 9...
2 Pneumatic Function Fittings Sensor Fitting- PF x SPP anjo olt F Product F number O/ thread thread /F tube SPP SPP 8 8" 8,, 8" 9,,,,9 8 ", 7, " 9,,, 9, 9 This sensor fitting produces an end of stroke signal when exhaust back pressure in a cylinder decays below a set value. t should be mounted directly on the cylinder and can be used with a flow control device mounted into the top port. t is recommended that the sensor supply pressure to port be the same as the nominal working pressure of the cylinder. Sensor Fitting- PF x NPTF anjo olt F Product F number O/ thread thread /F tube NPTF NPTF 8 " 8" 8,, 8" 9, 9,, 8, 9 " 8 " ", 7, " 9,,,,7 " This sensor fitting produces an end of stroke signal when exhaust back pressure in a cylinder decays below a set value. t should be mounted directly on the cylinder and can be used with a flow control device mounted into the top port. t is recommended that the sensor supply pressure to port be the same as the nominal working pressure of the cylinder. Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under Technical ata. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/L 9... /97
3 Metric & nch Pilot Operated heck Valve (locking Fitting) esigned for direct cylinder mounting Safer pneumatic systems Push-in or threaded ports available ompact banjo design Technical ata Medium: ompressed air Operating : - bar Operating Temperature: to +8 nlet Port:,, 8,, mm Push-in Fittings, 8, Push-in Fittings 8,, 8, NPTF ed Ports Outlet Port: 8,, 8, SPP 8,, 8, NPTF Ordering nformation To order, quote appropriate product number from the tables on the following pages. Product numbering system is designed to make identification and selection simple: Pilot Port: M - UNF Series Number Type Shape / Tube Tube / Tube s,, 8,, mm O/, 8, O/ Tubing Types: Nylon or, polyurethane and other plasticised or unplasticised tubing which conforms to the tolerances specified in S 9, Part, 97, light and normal duty, N 778, N 7, NF 9- Materials Nickel plated brass body Nickel plated brass collet Plastic sealing washer Nitrile and polyurethane elastomeric parts Zinc plated brass banjo bolts 7/98 N/L 9...
4 Pneumatic Function Fittings Pilot Operated heck Valve (locking Fitting) - PF x SPP thread Product SQ number O/ thread tube SPP 8 8",,, 9,8 M 8 8",,, 9,8 M 8 ", 8, 7,,8 M 88 8 ", 8, 7,,8 M " 8,,,8 9, M 8 8",7,,8 9, M 8 " 9,7, 7,8, M ) nlet Port ) Outlet Port ) Pilot Port Note: For mounting in pairs on a cylinder Pilot Operated heck Valve (locking Fitting) - SPP threaded port x SPP thread Product ody SQ number port thread SPP 88 8 SPP 8 7,,, 9,8 M 88 8 SPP, 8, 7,,8 M 88 SPP, 8, 7,,8 M 88 8 SPP 8 7,,,8 9, M 88 SPP,, 7,8, M ) nlet Port ) Outlet Port ) Pilot Port Note: For mounting in pairs on a cylinder Pilot Operated heck Valve (locking Fitting) - PF x NPTF thread Product ody SQ number port thread NPTF 8 PF 8,,, 9,8 - UNF 8 PF, 8, 7,,8 - UNF 8 8PF 8,7, 7, 9, - UNF 78 PF 9,7, 7, - UNF ) nlet Port ) Outlet Port ) Pilot Port Note: For mounting in pairs on a cylinder Pilot Operated heck Valve (locking Fitting) - NPTF threaded port x NPTF thread Product ody SQ number port thread NPTF 88 8NPTF 8,,, 9,8 - UNF 88 NPTF 9, 8, 7,,8 - UNF 88 8NPTF 8,, 7, 9, - UNF 88 NPTF 9,, 7, - UNF ) nlet Port ) Outlet Port ) Pilot Port Note: For mounting in pairs on a cylinder N/L /98
5 uidelines for Typical nstallation to control valve pilot signal The pilot operated check valve should be mounted directly onto a cylinder. This installation minimises the volume of air trapped in the system and gives the fastest blocking response. Pilot haracteristics These charateristics were measured with pressure on port (secondary pressure), but no pressure on port. The pilot pressure was gradually increased until the value opened. Pilot pressure (bar) 7 8 (bar) Outlet Port /8 Pilot pressure (bar) 7 8 (bar) Outlet Port / 7/98 N/L 9...
6 Pilot pressure (bar) 7 8 (bar) Outlet Port /8 Pilot pressure (bar) Note: The pilot signal pressure should be an on/off signal, rather than one that is allowed to decay slowly. 7 8 (bar) Outlet Port / Flow hart Flow at bar Flow (/m) 8" 89 " 7 8", ",9 Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under Technical ata. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. 7/98 N/L 9...
7 Metric & nch Reducing Fitting ompact units System running cost savings by optimising cylinder pressure esigned for mounting on valves Push-in or threaded ports available Relief feature to protect against over pressure Technical ata Medium: ompressed air Operating : Primary pressure - bar maximum -8 bar maximum Operating Temperature: to +8 Outlet Port:,, 8, mm Push-in Fittings,,, 8, Push-in Fittings 8,, 8, NPTF ed Ports nlet Port: 8,, 8, SPP 8,, 8, NPTF Tube s,, 8, mm O/,,, 8, O/ Tubing Types: Nylon or, polyurethane and other plasticised or unplasticised tubing which conforms to the tolerances specified in S 9, Part, 97, light and normal duty, N 778, N 7, NF 9- Materials Nickel plated brass body Nickel plated brass collet Plastic sealing washer Nitrile and polyurethane elastomeric parts Zinc plated brass banjo bolt Ordering nformation To order, quote appropriate product number from the tables on the following pages. Product numbering system is designed to make identification and selection simple: Series Number Type Shape / Tube Tube / 7/98 N/L 9...
8 Pneumatic Function Fittings Reducing Fitting - PF x SPP thread Product SQ number O/ thread (max) /F tube SPP 8 8", 7, 7, 9,8 8 ", 8 7,, ", 8 7,, " 8, 88,8 9, 8 8",7 88,8 9, ) nlet Port ) Outlet Port Note: For mounting in ports & of a control valve Reducing Fitting - SPP threaded port to SPP thread Product SQ number ody thread (max) /F Port SPP 88 8" SPP 8" 7, 7, 7, 9,8 88 " SPP ", 8, 7,,8 88 8" SPP 8" 7, 88,,8 9, 88 " SPP ", 89, 7 9,, ) nlet Port ) Outlet Port Note: For mounting in ports & of a control valve Reducing Fitting - PF x NPTF thread Product SQ number O/ thread (max) /F tube NPTF 8 PF 8, 7, 7 9,8 8 PF 8, 7, 7 9,8 8 PF, 8, 7,8 8 PF, 8, 7,8 8 PF 8 8, 88, PF 8,7 88, 9 78 PF 9,7 9, 7 ) nlet Port ) Outlet Port Note: For mounting in ports & of a control valve Reducing Fitting - NPTF threaded port to NPTF thread Product SQ number ody thread (max) /F Port NPTF 88 8 NPTF 8, 7, 7 9,8 88 NPTF 9, 8, 7, NPTF 8, 88, 9, 88 NPTF 9, 9, 7, ) nlet Port ) Outlet Port Note: For mounting in ports & of a control valve N/L /98
9 uidelines for Typical nstallation P P The regulator is designed to be mounted in the cylinder connection of a control valve. The adjustment screw is turned to set the operating pressure, clockwise rotation causes the operating pressure to increase, and an anticlockwise rotation causes the pressure to decrease. The unit is designed to be self relieving so that, if the pressure rises above the required level, excess pressure is automatically vented. Flow haracteristics nch Version Flow (SFM) 8 Flow (SFM) nlet / NPTF- bar nlet /8 & / NPTF- bar / NPTF- bar /8 & / NPTF- bar / NPTF- bar /8 & / NPTF- bar 7/98 N/L 9...
10 Flow haracteristics Metric Version 8 Flow (l/min) 8 Flow (l/min) nlet /8 - bar nlet / - bar /8 - bar / - bar /8 - bar / - bar Flow (l/min) nlet /8 & / - bar /8 & / - bar /8 & / - bar Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under Technical ata. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. 7/98 N/L 9...
11 Metric Pilot Operated heck Valve (locking Fitting) Very compact units Positive tube anchorage Safer pneumatic systems Technical ata Medium: ompressed air Operating : - bar Operating Temperature: to +8 nlet Port: 8,, 8, SPP Outlet Port: 8,, 8, SPP Signal Port: M Tubing Types: Nylon or, polyurethane and other plasticised or unplasticised tubing which conforms to the tolerances specified in S 9, Part, 97, light and normal duty, N 778, N 7, NF 9- Materials Nickel plated brass body Plastic sealing washer Nitrile and polyurethane elastomeric parts Zinc plated brass banjo bolts Ordering nformation To order, quote appropriate product number from the tables on the following pages. Product numbering system is designed to make identification and selection simple: Series Number Type Shape / Tube Tube / /99 X 9...
12 ˇˇˇˇˇˇˇˇˇˇˇˇˇ Pilot Operated heck Valve (locking Fitting) - Female to male SPP thread Product ody SQ number port thread NPTF 88 SPP 7,,, 9,8 M 88 SPP, 8, 7,,8 M 88 SPP, 8, 7,,8 M 88 8SPP 8 7,,,8 9, M 88 SPP,, 7,8, M ) nlet Port ) Outlet Port ) Signal Port Note: For mounting in pairs on a cylinder Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under Technical ata. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. ˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇˇ X 9... /99 ˇˇˇˇˇˇˇˇˇˇˇˇˇ
13 Metric & nch Reducing Fitting ompact units System running cost savings by optimising cylinder pressure esigned for mounting on valves Push-in or threaded ports available Relief feature to protect against over pressure Technical ata Medium: ompressed air Operating : Primary pressure - bar maximum -8 bar maximum Operating Temperature: to +8 Outlet Port:,, 8, mm Push-in Fittings,,, 8, Push-in Fittings 8,, 8, NPTF ed Ports nlet Port: 8,, 8, SPP 8,, 8, NPTF Tube s,, 8, mm O/,,, 8, O/ Tubing Types: Nylon or, polyurethane and other plasticised or unplasticised tubing which conforms to the tolerances specified in S 9, Part, 97, light and normal duty, N 778, N 7, NF 9- Materials Nickel plated brass body Nickel plated brass collet Plastic sealing washer Nitrile and polyurethane elastomeric parts Zinc plated brass banjo bolt Ordering nformation To order, quote appropriate product number from the tables on the following pages. Product numbering system is designed to make identification and selection simple: Series Number Type Shape / Tube Tube / 7/98 N/L 9...
14 Pneumatic Function Fittings Reducing Fitting - PF x SPP thread Product SQ number O/ thread (max) /F tube SPP 8 8", 7, 7, 9,8 8 ", 8 7,, ", 8 7,, " 8, 88,8 9, 8 8",7 88,8 9, ) nlet Port ) Outlet Port Note: For mounting in ports & of a control valve Reducing Fitting - SPP threaded port to SPP thread Product SQ number ody thread (max) /F Port SPP 88 8" SPP 8" 7, 7, 7, 9,8 88 " SPP ", 8, 7,,8 88 8" SPP 8" 7, 88,,8 9, 88 " SPP ", 89, 7 9,, ) nlet Port ) Outlet Port Note: For mounting in ports & of a control valve Reducing Fitting - PF x NPTF thread Product SQ number O/ thread (max) /F tube NPTF 8 PF 8, 7, 7 9,8 8 PF 8, 7, 7 9,8 8 PF, 8, 7,8 8 PF, 8, 7,8 8 PF 8 8, 88, PF 8,7 88, 9 78 PF 9,7 9, 7 ) nlet Port ) Outlet Port Note: For mounting in ports & of a control valve Reducing Fitting - NPTF threaded port to NPTF thread Product SQ number ody thread (max) /F Port NPTF 88 8 NPTF 8, 7, 7 9,8 88 NPTF 9, 8, 7, NPTF 8, 88, 9, 88 NPTF 9, 9, 7, ) nlet Port ) Outlet Port Note: For mounting in ports & of a control valve N/L /98
15 uidelines for Typical nstallation P P The regulator is designed to be mounted in the cylinder connection of a control valve. The adjustment screw is turned to set the operating pressure, clockwise rotation causes the operating pressure to increase, and an anticlockwise rotation causes the pressure to decrease. The unit is designed to be self relieving so that, if the pressure rises above the required level, excess pressure is automatically vented. Flow haracteristics nch Version Flow (SFM) 8 Flow (SFM) nlet / NPTF- bar nlet /8 & / NPTF- bar / NPTF- bar /8 & / NPTF- bar / NPTF- bar /8 & / NPTF- bar 7/98 N/L 9...
16 Flow haracteristics Metric Version 8 Flow (l/min) 8 Flow (l/min) nlet /8 - bar nlet / - bar /8 - bar / - bar /8 - bar / - bar Flow (l/min) nlet /8 & / - bar /8 & / - bar /8 & / - bar Warning These products are intended for use in industrial compressed air systems only. o not use these products where pressures and temperatures can exceed those listed under Technical ata. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. 7/98 N/L 9...
Quick Release Couplings 233 Series
Quick Release ouplings 233 Series 4mm - 9mm I/ hose 1 8" - 1 4" SP thread Low pressure drop across coupling High flow rate ompact construction One hand operation Robust construction Various connection
More informationNon-Return Valves T55 Series
T55 Series In-Line, Non-Return Valves M5, 1 8", 1 2" BSPP, BSPT, NPT Permit free flow of air in one direction only Simple, reliable design Light weight Silicone free Low cracking pressure Technical ata
More informationC 0G 00 N/US
G, GP, G, GP In-line flow regulators (block form) Uni-directional Ø /... / inch, Ø 4... mm High flow performance In-line or panel mounting Adjustment can be locked aptive regulator needle will not blow
More informationNickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO
Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8
More informationISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4
Port sizes 1 / - 1 and 1 /NPT - 1 /NPT Sub-bases tovd 3 specification, for ISO sizes #1, #, #3 and # Universal bases for ISO sizes #1 and #, side and bottom ported Technical Data edium: See individual
More informationSPCH/ Blowing block
> > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3
More informationR84G - Excelon Plus Modular System Pressure regulators
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Easy to read flush mounted integrated pressure gauge as
More informationPneufit Metric Series Push-In Tube Fittings 4 mm to 14 mm Tube Sizes M5 to 1/2" ISO G and ISO R Thread Options
Section 2 Pneufit Metric Series Push-In Tube Fittings 4 mm to 14 mm Tube Sizes M5 to 1/2" ISO G and ISO R Thread Options Metric Series Product Numbering System...............FIT-2-2 Metric Series Shapes
More informationF l o w c o n T R o l v a l v E S
Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,
More informationIP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators
Page 1 of 6 TI-P510-01 H Issue 5 IP2, IP2 and IP2D ISO 9001 Spirax-Monnier International ompressed ir Filter/ Regulators ert. No. LRQ 0963008 Description The IP range of Spirax-Monnier international compressed
More informationNugget 120 V14 Series
Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus
More information(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)
This exhaust needle valve, which comes with silencer, controls the exhaust flow rate. The valve can be attached directly to a solenoid valve where a cylinder or like mechanism has no sufficient space around
More information3-Way Pressure-Reducing Cartridge, Size 2 4
-Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationR18 General purpose pressure regulators
> > Port size: / & (ISO G, PTF) > > Can be installed at any point in the compressed air system without regard to accessibility pilot regulator can be installed in the most convenient location > > Accurate
More informationParker Legris Machine Safety: Product Sheets
Parker Legris Machine Safety: s Blocking Fittings Blocking fittings include a pneumatic monostable 2/2 normally closed (N) function. These fittings are directly installed onto the pneumatic cylinder supply
More informationPN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12
PN LINE PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN
More informationAir Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.
Air Saving Valve Series R Pressure Valve Series Q Flow Valve P r.9.7 2..3.1 D -FE KE -FG -FP -FM.1.2.2.3 pressure (MPa) -D -T P ow valve Fl N AQ V e n by o i t p nsum n stroke o c r i r a Cuts g the retu
More informationBL68 - Olympian Plus, plug-in system Filter/regulators and lubricators
>> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationB74G - EXCELON Modular System General purpose filter/regulator
> Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory
More informationSO 9001 I ACCESSORIES
ISO 9001 ESSORIES ESSORIES INDEX Page In-Line Mounted Flow ontrol Valves 3 In-Line Mounted heck Valves 3 Quick Exhaust, heck and Shuttle Valves In-Line Ported Lockout Valves 5 Mufflers 6 Fittings 7-9 2
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationV83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability > > Modular design - Maxseal valves > > able terminations inside coil housing
More informationCoiling Tube with Twist-Proof Fitting
http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Anti-Twisting Coiling Tube for Air Tool Coiling Tube with Twist-Proof Fitting 306 Avoid Twisted Tube Problem
More informationCalibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New
> Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,
More informationCoding of banjo flow controllers. Actuation M = Manual S = Screwdriver
Flow control valves Unidirectional and bidirectional (meter-in, meter-out, orifice) banjo flow controllers Series SCU, MCU, SVU, MVU, SCO, MCO Ports M5, 1/8, 1/4, 3/8, 1/2 BSPP (without adapters) General
More informationPiloted Non-Return Valves
ed Non-Return Valves ed non-return valves are designed to protect installations: if the compressed air supply is removed, they lock the air supply to the cylinder, thus maintaining it in position. Product
More informationBasic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012
Basic Pneumatics Module 8: Pressure control valves PREPARED BY Academic Services April 2012 Applied Technology High Schools, 2012 Module 8: Pressure control valves Module Objectives After the completion
More informationCautions : 1. Be careful when you release the Stop Fitting with some internal pressure
The flow-shut mechanism will operate to stop the air flow when the tube is disconnected and will allow air flow when the tube is connected. The double-passage structure facilitates easy connection and
More informationOperating manual for the pressure transducer unit CCS 1000
Operating manual for the pressure transducer unit CCS 1000 Please read the operating manual before using the device. 1 Content: 1. General description 2. Technical data 3. Operation 4. Scope of supply
More informationStandard Specifications
NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.
More informationSeries MX pressure regulators 3/
CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges
More informationINDUSTRIAL PNEUMATICS - air treatment units. FIL filter
Due to its metal construction, the entire range of NEW DEAL elements is resistant to heavy duty working conditions. Designed for high pressure application (up to 18 bar). FIL filter Degree of filtration:
More informationPower Valve: Precision Regulator. High precision, large capacity relief regulator
Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationNickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO
Flow Control Valves NORTH MERICN FITTINGS & FLOW CONTROL VLVE CTLOG > Release 8.6 Nickel-Plated Brass Right ngle Flow Control Valves /Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel esign : Meter-Out,
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationAir Saving Valve. Pressure Valve Flow Valve
Air Saving Valve Series Series Pressure Valve Flow Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction
More informationPneumatic valve islands
Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented
More informationAir Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv
CAT.ES-173 A Air Saving Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction ratio (%) 3 1.1.1...3 pressure
More informationNugget 120 V14 Series
Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationWARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.
GSR500 Ram Assembly General Description The GSR500 single post lift / ram uses a 3-1/4 air powered cylinder, which is welded to a heavy gauge base. It is normally used to raise and lower a fluid handling
More informationAir preparation units
Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator
More informationCautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the
The Silencer, connected to the exhaust port of a device, suppresses the exhaust noise. The Silencer displays an excellent noise suppression effect. Three types are available for your selection. The element
More informationRelief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm
s s RS Differential NB 9.5mm RVA In-line Differential NB 6 to 19mm RV Direct Acting NB up to 9mm LPR Low Pressure Differential NB 8mm We design, machine, build and test all our products on one site in
More informationIntegrated Fittings. Flow Controls. Check Valves. Blocking Valves. Slow Start Fittings. Threshold Sensor Valves
Integrated Fittings Flow ontrols ompact & Miniature Styles Brass & omposite Bodies Right Angle & In-line Inch & Metric Sizes Direct Mounting heck Valves ompact & light weight Inch & Metric sizes, BSPT,
More information(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type
In response to high-speed drive cylinder. The Quick Exhaust Valve comes with a built-in Quick Fitting. The Valve serves also as a shuttle valve. The exhaust port, having a throttling function, enables
More informationPneumatic pressure switch 20DD
Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better
More informationPressure-Relief Cartridge Valve, Size 4
Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure
More information(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD
The polyurethane tube, featuring excellent flexiblity, helps compact piping requiring small bending radius. The useful cut marks at 500mm interval are printed on the tube. Model UD0425 UD0640 UD0860 UD1075
More informationLeak free Pipe Rupture Valve for Excavators
Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationFlow control valves Series RFU - RFO 2/
CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5
More informationIP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators
L ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification
More informationlternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0
ir line equipment P1H, PTH Filter/Regulator- Lubricator Combination Units 07 Series Compact design Filter removes liquids and solid particles down to 5 µm Push to lock adjusting knob with tamper resistant
More informationChange Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.
http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Three-way Changeover Valve Change Valve Changeover Air Direction by 90 Lightweight and Compact Design. Fine Operability and
More informationRegulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2
Regulator: Modular Type with ack flow Mechanism R3 to 6 How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure (built-in check valve with back flow mechanism).
More information3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX
/-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationHand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.
http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Hand Valve Series 556 Control Open/Close for Air Supply. Release Residual
More informationPrecision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
More informationSeries AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use
CAT.ES20-19 A Speed Controller with One-touch Fitting for Clean Room Series AS-FPQ/AS-FPG Series AS-FPG Series AS-FPQ Speed controllers for clean room use AS-FPQ: Brass (electroless nickel plated) and
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationCOMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6
COMMON PRECAUTIONS Page 1 of 6 These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution",
More informationCautions : 1. The gauge orientation on the GPU and GPM types can be changed by using
The compact-size pressure gauge can be installed in small spaces. With the built-in tube fitting type, tube connection is the only necessary step before pressure indication. Fluid medium Indicated pressure
More informationMEGR-1912 Instruction Manual
MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX
More informationFilter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX
Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with gauge suitable for ATEX 1 00119372 Version Parts Mounting orientation Working min./max. Medium Medium temperature
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationInsert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.
http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS Protection Ring from Deformation Insert Ring 668 Protect tubes from deformation. Ultra soft tube is connectable to Fitting. Necessary for the connection
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationPressure regulators Manually operated Fine setting valves. Brochure
Pressure regulators Manually operated s Brochure Pressure regulators Manually operated s Qn = 9 l/min Actuating element: Push button Internal thread Poppet valve Qn = 9 l/min Actuating element: Push button
More informationInstallation and operation Manual. Bermad Surge Anticipation Valve. Model No 435
Instruction manual Bermad surge anticipation manual Model No 435 Installation and operation Manual Bermad Surge Anticipation Valve Model No 435 Bermad Water Technologies Rev 0 5/05/2015 7 Inglewood Drive,
More informationTANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING
CONRADER VALVES TANK MATE AUTOMATIC DRAIN VALVE INSTALLATION KIT INCLUDES: TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING WV-1 DRAIN VALVE TOOLS REQUIRED: 3/4 WRENCH **TUBING CUTTERS ** NEEDED TO CUT METAL
More informationINSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
More informationSDM to 8 sections monoblock valve D1WWDA02A
SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information
More informationP33 Safety Exhaust Valve Externally Monitored. Bulletin 0700-B14 ENGINEERING YOUR SUCCESS.
P Externally Monitored ulletin 07004 ENGINEERING YOUR SUESS. Features Externally Monitored Function When applications demand a safe environment you can count on safety valves from Parker Hannifin. The
More informationBudget Range Operators Handbook
Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk
More informationscrew fittings - nickel plated brass series SC
screw fittings - nickel plated brass series SC SC SCC SC SC SC SC SC SCC SC SC SC SCC SC SC SC2C SC2 SC2 SC SC3 SC3 SC0 SC design screw fitting with swivel nut connection 1/"...1/2" optionally cylindrical
More informationPanel-mounted valves Series T, Ø 22.5 mm
Series T, Basic valve 3/2-way, M5 (10/32 UNF) M 5 and G 1/8 2.122 Basic valve 3/2-way, M5 (10/32 UNF) M 5 and G 1/8 2.122 Push button 18-T-23-011 2.126 Mushroom 18-T-23-012 2.126 2-position switch 18-T-23-013
More informationCylinder Controls. Operating information. For ATEX specific products contact Sales Office. 2/2 Blockers. PDE2600PNUK Parker Pneumatic
A range of speed controls, flow controls and back pressure sensors designed to be mounted directly onto the cylinder in the optimum position for maximum performance. "Push-in" or threaded connection Multifunction
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More information(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure
This type of tube fitting comes in eight lengths to suit your applications. The tube fitting, provided with a hexagonal hole, can be easily installed using an Allen wrench, even in a narrow or limited
More informationFloat Operated Level Controllers
CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions
More informationACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS
ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven
More information(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type
These are air finger models featuring light weight and miniature size. Blank fingers are available for the K type fingers as option. R-guide leaves no possibility of misalignment. The blank finger can
More informationVPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control
VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS FLOJET Beer Pump Panels MODEL NO. 66134-1 66134-2 66134-3 66134-4 IMPORTANT INFORMATION This manual has been prepared to assist you in the operation of Perlick Beer
More informationInstallation and Service Manual
An Actuant Company Installation and Service Manual Heavy Duty Hydraulic Stabilization Legs CONTENTS Part # 3010003129 REV 0D Section Page 1.0 Receiving Instructions 2 2.0 Safety Issues 2 3.0 Hydraulic
More informationPush-In Fitting Type Silencer
http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type 540 Reduce Exhaust Noise from Exhaust Port. Excellent Silencing Effect. Selection from 3 types. Push-In Fitting
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationOperation Manual. Diaphragm Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Diaphragm Sensed Gas (AP/AZ/AK Models: 20, 100, 500, 1000, 1000T 10PA, 1100, 1200, 12PA, 1300, 1400T, 14PA,
More information1200 Series Pressure Regulators
SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of
More informationREGULATORS FOR SPECIFIC APPLICATIONS
SINGLE-STAGE REGULATORS FOR NITROUS OXIDE AND CARBON DIOXIDE (MODELS SG9011, SG9012, SG9014) Nitrous Oxide and Carbon Dioxide frequently cause ordinary regulators to freeze up. Models SG9011, SG9012 and
More informationV43 Pressure Actuated Water Regulating Valve
FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled
More information