1 Rada-Presto TF2020 and TF2020S PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1

2 INDEX Page INTRODUCTION 3 DESCRIPTION 3 SAFETY:WARNINGS 3 PACK CONTENTS 4 DIMENSIONS 5 SPECIFICATION 6 INSTALLATION 8 COMMISSIONING 9 OPERATION 14 FAULT DIAGNOSIS 15 MAINTENANCE 16 SPARE PARTS 23 ACCESSORIES 25 CUSTOMER CARE Back Cover 2

3 INTRODUCTION Rada-Presto taps are specified to meet the highest standards of safety, comfort and economy as demanded by today s users. All Rada products are designed, manufactured and supported in accordance with accredited BS EN ISO 9001:1994 Quality Systems. The taps are vandal-proof 1/2" push action mixer taps suitable for washbasin installation. They incorporate an automatic time delayed shut-off, self cleaning mechanism and internal components manufactured from anti-corrosion and anti-liming materials. The TF2020S model incorporates a security "S" cartridge to prevent continuous flow should the push-button be deliberately held down. Product range DESCRIPTION Rada-Presto TF2020 chrome 1/2" for individual washbasin installation, supplied with seat joint, sealing washer, joint and stainless steel flexible couplings with 1/2" rotating nuts. The tap body and push-button are chrome plated brass. A grey skirt indicates mixed water supplies. Rada-Presto TF2020S chrome 1/2" for individual washbasin installation and incorporating the security "S" cartridge is supplied with seat joint, sealing washer, joint and stainless steel flexible couplings with 1/2" rotating nuts. The tap body and push-button are chrome plated brass. A grey skirt indicates mixed water supplies. SAFETY: WARNINGS Rada products are precision-engineered and should give continued superior and safe performance, provided: 1. They are installed, commissioned, operated and maintained in accordance with the recommendations given in this Manual 2. Periodic attention is given, as necessary, to maintain the product in good functional order. Recommended guidelines are given in the MAINTENANCE section. Provided it is installed, commissioned, operated and maintained within these recommendations, the risk of failure, if not eliminated, is reduced to the minimum achievable. 3

4 PACK CONTENTS Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. TF2020 and TF2020S 1 x Sealing Washer 1 x Joint Seal 1 x Joint 1 x TF2020 or TF2020S 1 x Fixing Nut 3 x Stop Pins Note: Two are already installed in temperature adjustment lever. 2 x 1/2 Adaptor 2 x Strainer Seals 2 x Plastic Washer 2 x Compression/ flat-face adaptors 1 x Product Manual 4

5 DIMENSIONS TF2020 and TF2020S NOTE:- NOT TO SCALE - All dimensions are in millimetres 5

6 SPECIFICATION Normal Operating Conditions are considered as: - inlet dynamic pressures nominally balanced to within 10% of each other during flow. - a differential of approximately 50 o C between the hot and cold inlet temperatures, and with differentials of o C between the blend setting and either supply. - daily usage of 1-6 hours. - installation and usage environment not subject to extremes of temperature, unauthorised tampering or wilful abuse. Other Applications For information on other specific applications or suitability, refer to Kohler Mira Ltd, or Local Agent. Disinfection In applications where system chemical disinfection is practised, chlorine can be used (calculated chlorine concentration of 50 mg/l (ppm) maximum in water, per one hour dwell time, at service interval frequency). Such procedures must be conducted strictly in accordance with the information supplied with the disinfectant and with all relevant Guidelines/Approved Codes of Practice. If in any doubt as to the suitability of chemical solutions, refer to Kohler Mira Ltd, or Local Agent. Pressures and Flow Rates For optimum performance, dynamic supply pressures should be nominally equal. Recommended Minimum Running Pressure: 0.15 bar (with regulator removed). Recommended Maximum Static Pressure: 10 bar. Time cycle: Preset to approximately 10 seconds, subject to site conditions (Low water pressures may reduce this time period. High water pressure may increase this time period). Time duration may be increased in six graduated steps to approximately 16 seconds (See COMMISSIONING) 6

7 Flow rates: Flow Curves For conservation of energy and water, an economical flow rate may be obtained by setting the internal flow adjuster to one of five positions. The graph shows the flow rates for each of the five positions for all models. All taps are fitted with a flow straightener and are supplied adjusted to position S4. Note: An optional flow regulator (4 litres/min.) is also available as a spare. TF2020 and TF2020S Low Pressure Flow Rate (l/min) 12.5 S5 10 S4 7.5 S S2 S Running Pressure (bar) TF2020 and TF2020S High Pressure Flow Rate (l/min) S5 S4 S3 S2 S Running Pressure (bar) Connections: Inlet supply connections are made via 2 x 1/2" BSP female nuts at the end of flexible inlet tails. 7

8 INSTALLATION Fit to Basin Important! Flush supply pipework thoroughly before connection. 1. Remove retaining nut, pipe clamp and rubber gasket from mixer tap. 2. Connect flexible tail connectors. Make sure O-rings are fitted correctly. 3. Fit tap to basin. Make sure basin sealing ring is concentric with the mixer tap body. O-rings Basin Tap Body Rubber Gasket Pipe Clamp Retaining Nut 4. Fit rubber gasket and pipe clamp. Screw on retaining nut. Flexible Tail Connectors 5. Connect the flexible tail connectors to the 1/2 Adaptor (Make sure the plastic washers are in place). Note! Check valves are located in the flex tails. 6. Fit the strainers seals supplied to the checkvalve assemblies. 7. Fit 15mm compression isolating valves (not supplied) using the flatface adaptors supplied. 8. Refer to COMMISSIONING before operating the mixer tap. Flexible tail connector Plastic washer 1/2" Adaptor Strainer Seal Flat-face adaptor 15mm compression isolating valve (not supplied) 8

9 COMMISSIONING Commissioning must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. Commissioning Checks 1. Turn on water supplies to the tap. 2. Operate the tap (see section OPERATION) and check: - Flow-rate is sufficient for purpose. - The connection to the supply is watertight. The flow control and flow time are preset at manufacture, however both may be adjusted, see below. Flow Rate Control Setting The TF2020 and TF2020S are factory set to flow position S4. Should the installation pressures require adjustment of the flow rate, any one of the five different flow rate positions, S1 to S5 may be selected, with S5 being the least restrictive. Adjust the flow rate as follows: 1. Isolate the water supply. Remove the tap knob and unscrew the head assembly (see MAINTENANCE). 2. Remove the head assembly and attached cartridge. 3. Turn the adjusting ring (coloured black on the TF2020 and green on the TF2020S) on the cartridge clockwise or anticlockwise according to the flow rate required (see Figure 1 and Flow Rate Adjustment Chart). Note: Taps are supplied set in position S4. 4. Install the cartridge and head assembly into the body (see MAINTENANCE). 9

10 + - Flow Rate Control Setting Adjustment Figure 1 Position Visible aperture S1 S2 S3 S4 S5 (Refer to flow curves chart for pressure/flow rates) Flow Rate Adjustment Chart 10

11 Flow Time Duration Setting (Refer to Figure 3) The flow time duration setting has been factory set in position 6, which gives approximately 10 seconds flow duration, but can be adjusted if required. A special tool is available from Customer Support, free of charge (see ACCESSORIES). There are six possible positions, which are set as follows: 1. Remove the knob (see MAINTENANCE). 2. Insert the special tool into the black upper stop and turn to the desired setting. As the black ring is rotated, a lug will appear in the window in the skirt. It is important that the black ring is adjusted so that the lug is positively located in the window in one of the six positions. To increase the time duration, turn the black ring clockwise. Each position changes the duration by approximately one second (position 1 = approximately 16 seconds, position 6 = approximately 10 seconds). Upper Stop - Special Tool Skirt Window + Flow Time Duration Setting Figure 3 11

12 Flow Regulator (Refer to Figure 4) An optional flow regulator is available as a spare and must be installed as shown in Figure 4. This will provide a comfortable flow of about 4 l/min at a pressure of between 1 and 10 bar. Note: The flow regulator will not function at pressures less than 1 bar. Flow Regulator Flow Regulator Figure 4 Flow Straightener Hot Water Temperature Control (Refer to Figure 5) The maximum outlet water temperature can be limited by inserting stop pins (supplied) into the mixer lever. The stop pins limit the mixer lever travel. Insert the stop pins as follows: Note: The TF2020 and TF2020S are supplied with two pins fitted. This limits the maximum blend temperature to 40 o C, providing the hot supply temperature does not exceed 60 o C. 1. Remove the mixer lever (see MAINTENANCE). 2. Insert the stop pins on the mixer lever as required (see chart at Figure 6) and tap home with a mallet or other suitable tool. 12

13 Mixer Lever Stop Pins Mixer Lever Figure 5 For a 40 C outlet water temperature with a hot water inlet temperature of 50 C fit one pin. For a 40 C outlet water temperature with a hot water inlet temperature of 60 C fit two pins. For a 40 C outlet water temperature with a hot water inlet temperature of 70 C fit three pins. 1 Stop 2 Stops 3 Stops 50 o 60 o 70 o Mixer Lever Temperature Setting Chart Figure 6 13

14 OPERATION TF2020 The TF2020 is simple to use. A firm push on the tap knob starts the water flowing for the duration of the flow timing. The water temperature and flow timing is factory set, but this can be altered (see COMMISSIONING). If the tap knob is pushed again whilst the tap is flowing a further preset cycle will commence. TF2020S The TF2020S is fitted with a security "S" cartridge. The tap is operated by a firm push on the tap knob, however, flow will not commence until the tap knob is released. The water temperature and flow timing is factory set but this can be altered (see COMMISSIONING). If the tap knob is pushed again whilst the water is flowing the flow will cease. The tap knob has to be released again to achieve water flow. 14

15 FAULT DIAGNOSIS Symptom 1. Tap not working. (No flow) 2. Tap will not shut off. 3. Tap shuts off too quickly. Cause/Rectification a. Check Inlet supplies. b. Remove the cartridge and clean the mechanism under running water: refer to MAINTENANCE for removal. Note: Cartridges may only be cleaned by flushing through under a jet of clean water to remove lodged particles. Do not descale. Cartridges are not serviceable, and must not be dismantled. a. Check the piston seal for cleanliness. b. Ensure that the spindle spring slides freely in its aperture. Refer to MAINTENANCE for removal. a. Check the cleanliness of the sealing cap in the piston. b. Check the spindle spring for damage. Refer to MAINTENANCE for removal. 15

16 General MAINTENANCE Rada products are precision-engineered and should give continued superior and safe performance, provided: 1. They are installed, commissioned, operated and maintained in accordance with our recommendations 2. Periodic attention is given as necessary to maintain the product in good functional order. Guidelines for frequency are given below. The maintenance requirement for taps in this series is minimal and concerns temperature, performance and functional checks and inspection, with cartridge renewal when necessary. In larger installations with a number of taps, it is good policy to maintain a small stock of cartridges so that no tap need be out of commission for more than the time it takes to exchange the cartridge. The minimum designed service life of all cartridges used in our products is five years under normal operating conditions. However, when supply conditions and/or usage patterns do not conform to 'normal operating conditions' the cartridge may need to be replaced more frequently (refer to SPECIFICATION for 'normal operating conditions'). The use of main supply-line or zone strainers (with a recommended maximum mesh aperture dimension of 0.5 mm) will reduce the need to remove debris at each shower control point. Rada Service Engineers/Agents will call by prior arrangement, if required. Service Contracts may be undertaken, subject to survey - details upon request. 16

17 Preventative/Precautionary Maintenance (Planned Maintenance Programmes) The frequency and extent of attention required will vary according to prevailing site and operational conditions however, the following guideline schedule is suggested to cover average duty and site conditions: Six-monthly Performance: check flow rate control and time delay are fit for purpose. Refer to COMMISSIONING for adjustment. Visual: check external component condition. Inspect for scale deposition, deformation, damage, corrosion, etc. Maintain or renew as necessary. Lubricate applicable components using only silicone-based lubricant. Lubricants Important: Use only silicone-based lubricants on this product. Do not use oilbased or other lubricant types as these may cause rapid deterioration of seals. Standard silicone-based lubricants may be used on all static seals, and threads, to assist refitting (e.g. Rocol MX22). Maintenance Procedures Maintenance must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. This tap series is designed for minimal maintenance under conditions of normal use. External surfaces may be wiped clean with a soft cloth, and if necessary, a mild washing-up type detergent or soap solution can be used. Caution: many household and industrial cleaning products contain mild abrasives and chemical concentrates, and should not be used on polished, chromed or plastic surfaces. Components are precision-made, so care must be taken while servicing to avoid damage. When ordering spare parts, please state product type, i.e. Rada-Presto TF2000, and identify part name and number (refer to the Spare Parts List). Protection against freezing: Turn off the incoming supply and push the tap several times to drain the system. Remove the cartridge (see Removal). 17

18 Removal - TF2020 and TF2020S Knob (Figure 7) Note: The knob is under spring pressure. 1. Lift the flap using the end of a small flat-ended screwdriver. 2. Insert a 3mm hexagonal key in the hole under the flap and engage it in the knob hexagon. Turn it 1 / 2 a turn anticlockwise against the stop - do not force it. 3. Remove the hexagonal key from the knob hexagon and pull off the knob. Remove the spring from inside the knob. 3 mm Hexagonal Key Knob Removal Figure 7 18

19 Skirt and Cartridge (Figure 8) 1. Remove the knob. 2. The skirt is a push/pull fit located in the tap body by a protruding dowel. Pull the skirt free of the tap body. 3. Unscrew the head nut from the tap body with the special tool or a suitable box spanner. 4. Remove the head assembly and the attached cartridge. Special Tool Upper Stop Head Nut Skirt Skirt and Cartridge Removal Figure 8 Flow Straightener (See Figure 9) 1. Insert the special tool in the flow straightener spout and unscrew anticlockwise. Flow Regulator (Optional) Flow Straightener Special Tool Flow Straightener Removal Figure 9 19

20 Mixer Lever (See Figure 10) Remove the mixer lever by unscrewing the hexagonal nut at the base. A 4 mm hexagonal key (not supplied) is required for this operation. Lift off the lever. 4 mm Hexagonal Key Mixer Lever Mixer Lever Removal Figure 10 20

21 Assembly - TF2020 and TF2020S Skirt and cartridge (Figure 11) 1. Insert the cartridge into the tap body with the special tool or suitable box spanner and tighten. 2. Fit the seal to the outer groove of the skirt. Align the protruding skirt dowel with the drilled recess in the tap body and push firmly into place. 3. Using the special tool, adjust the time delay ring to the desired setting if required (see COMMISSIONING). Special Tool Upper Stop Head Nut Skirt Skirt and Cartridge Assembly Figure 11 Knob (Figure 12) 1. Lift the flap on the skirt using the end of a small flat-ended screwdriver. 2. Insert the spring in the knob, place the knob on piston rod and push down against the spring pressure. 3. Insert a 3mm hexagonal key in the hole under the flap and engage it in the knob hexagon. Then turn it 1/2 turn clockwise to engage in the cartridge piston rod groove do not over tighten it. Withdraw the hexagonal key and close the flap. 3 mm Hexagonal Key Knob Assembly Figure 12 21

22 Flow Regulator Option (See Figure 13) 1. An optional 4 l/min flow regulator may be purchased (see SPARES). 2. Remove the flow straightener using the special tool (available from Customer Support) 3. Insert the flow regulator into the back of the flow straightener. 4. Install the flow straightener/regulator assembly using the special tool. Flow Regulator Flow Straightener Special Tool Mixer Lever (See Figure 14) Flow Regulator Assembly Figure 13 Insert the mixer lever into the tap body and secure with the hexagonal nut at the base of the mixer lever. A 4 mm hexagonal key (not supplied) is required for this operation. 4 mm Hexagonal Key Mixer Lever Mixer Lever Assembly Figure 14 22

23 Rada-Presto Spare Parts SPARE PARTS Flat-faced Inserts (3) Cartridge (TF2020) Cartridge - anti-blocking (TF2020S) Flow straightener/flow regulator set Grey skirt Knob set (TF2020) Knob set (TF2020S) Temperature lever assembly Strainer Seal Spring (TF2020s) FlexibleTail Assembly (Pair) 23

24 Rada-Presto TF2020 and TF2020S Spare Parts Diagram (TF2020S only)

25 ACCESSORIES The Special Tool and 3 mm Hexagonal Key are available to aid maintenance and flow duration adjustment. They are available from Customer Support, free of charge upon request. Special Tool with 3mm Hexagonal Key

26 REVISIONS AND CORRECTIONS August Revision: P3664/1 to P3664/2 Page Format Status Summary of Revisions 23 T A New spare part (887.29) added. 24 I A New spare part (887.29) added. B T R New date and issue changed. Key T = Text I = IIlustration A = Addition R = Revision B = Back cover F = Front cover 26

27 NOTES 27

28 Guarantee CUSTOMER CARE This product is guaranteed against any defect of materials or workmanship for one year from the date of purchase, provided that the product has been installed correctly and used in accordance with the instructions supplied. Any part found to be defective during the guarantee period will be replaced or repaired - at our option - without charge, provided that the product has been properly used and maintained. Routine cleaning and maintenance should be carried out in accordance with the instructions supplied. The product should not be modified or repaired except by a person authorised by Rada. Your statutory rights are in no way affected by this guarantee. After Sales Service - how we can help you We have a network of fully trained staff ready to provide assistance, should you experience any difficulty operating your Rada equipment. Spare Parts All functional parts of Rada products are kept for up to ten years from the date of final manufacture. If during that period, our stock of a particular part is exhausted we will, as an alternative, provide an equivalent new product or part at a price equating to the cost of repair to the old, bearing in mind the age of the product. Customer Care Policy If within a short time of installation the product does not function correctly, first check with the operation and maintenance advice provided in this Manual to see if the difficulty can be overcome. Failing this, contact your installer to ensure that the product has been installed and commissioned in full accord with our detailed installation instructions. If this does not resolve the difficulty, please ring your nearest Rada contact who will give every assistance and, if appropriate, arrange for the local Service Engineer or Agent to call on a mutually agreeable date. Contact: Rada Controls Kohler Mira Ltd Cromwell Road, Cheltenham, England, GL52 5EP, UK. Tel.: + 44 (0) Fax.: + 44 (0) P3664/1 Rada is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifications without notice. 28 Kohler Mira Limited, April 2004

320 c PRODUCT MANUAL IMPORTANT

320 c PRODUCT MANUAL IMPORTANT 320 c PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 INDEX Page INTRODUCTION 3 DESCRIPTION

More information

Ligature Resistant Head

Ligature Resistant Head Ligature Resistant Head PRODUCT MANUAL IMPORTANT INSTALLER: This product manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 Contents

More information

PRODUCT MANUAL IMPORTANT

PRODUCT MANUAL IMPORTANT PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 Contents Safety : Warnings...3 Advice...3

More information

15/3 THERMOSTATIC MIXING VALVE PRODUCT MANUAL IMPORTANT

15/3 THERMOSTATIC MIXING VALVE PRODUCT MANUAL IMPORTANT 15/3 THERMOSTATIC MIXING VALVE PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 INDEX Page

More information

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL Product Support Guarantee This product is guaranteed against faulty materials and workmanship for 12 months from date of purchase. For the guarantee to be valid, the unit must be installed by a competent

More information

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings 38 READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. LEAVE THIS BOOKLET WITH THE END USER FOR FUTURE REFERENCE

More information

PRODUCT MANUAL IMPORTANT

PRODUCT MANUAL IMPORTANT PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 INDEX Page SAFETY WARNINGS 3 ADVICE 3 INTRODUCTION

More information

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents bathrooms.com Concentric Thermostatic Shower Mixers Contents Page 3 - General Information & Safety Page 4 - Installation Page 5 - Concentric Valve Set-up Page 6 - Exposed fitting of Concentric Mixer Valves

More information

Twin & Triple Control Concealed Thermostatic Shower Valve

Twin & Triple Control Concealed Thermostatic Shower Valve Twin & Triple Control Concealed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS: 1. Introduction & Safety 1 2. Dimensions

More information

215-t3/222-t3 SERIES

215-t3/222-t3 SERIES 5-t3/-t3 SERIES PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. INDEX page INTRODUCTION 3

More information

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER CONTENTS 1. INTRODUCTION & SAFETY 1 2. DIMENSIONS 2 3. TECHNICAL DATA 3 4. OPERATION 4 5. COMPONENTS 5 6. SITE INSTALLATION

More information

SHOWER FITTINGS INSTRUCTIONS AND MAINTENANCE GUIDE. Please read carefully before use

SHOWER FITTINGS INSTRUCTIONS AND MAINTENANCE GUIDE. Please read carefully before use SHOWER FITTINGS INSTRUCTIONS AND MAINTENANCE GUIDE Please read carefully before use 1145094-W2-D 2 CONTENTS Introduction...4 Guarantee...4 Patents and Design Registration...4 Safety : Warnings...5 Pack

More information

Vegas Easyfit Kitchen Sink Mixer

Vegas Easyfit Kitchen Sink Mixer Vegas Easyfit Kitchen Sink Mixer Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading taps and showers expert.

More information

Self-help Temperature Adjustment

Self-help Temperature Adjustment Self-help Temperature Adjustment The Shower Valve temperature is pre-set to 42 C, but on certain installations the temperature may need to be adjusted. Note: The hot water supply must be above 60 C. Turn

More information

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap Avon 21 Self-closing taps (Push button) INSTALLATION INSTRUCTIONS B0992AA Self-closing basin pillar tap WaterMark AS/NZS 3718 WMK 25822 SAI Global The more stars the more water efficient WATER RATING www.waterrating.gov.au

More information

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003 PO Box 7, Rankine Street Johnstone, Renfrewshire Scotland. PA5 8BD Tel: 01505 321 455 Fax: 01505 336 287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

More information

V12 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL

V12 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL V12 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 1145094-W2-A

More information

These instructions are to be left with the user

These instructions are to be left with the user MIRA ECO SHOWER FITTINGS INSTALLATION & USER GUIDE These instructions are to be left with the user 1 CONTENTS Introduction 2 General 2 Pack Contents 3 Pack Contents 4 Specifications 5 Pressures 5 Dimensions

More information

215 SERIES. NSW Health approve the Rada 215 series TMV for use in healthcare buildings. PRODUCT MANUAL IMPORTANT

215 SERIES. NSW Health approve the Rada 215 series TMV for use in healthcare buildings. PRODUCT MANUAL IMPORTANT 5 SERIES AS 403. LIC.36 NSW Health approve the Rada 5 series TMV for use in healthcare buildings. PRODUCT MANUAL IMPORTANT INSTALLER: This Manual is the property of the customer and must be retained with

More information

These instructions are to be left with the user

These instructions are to be left with the user MIRA GEM 88 SHOWER CONTROL Installation & User Guide These instructions are to be left with the user CONTENTS Introduction... 3 Important Safety Information... 4 Pack Contents Checklist... 5 Dimensions...

More information

215 and 222 Series PRODUCT MANUAL

215 and 222 Series PRODUCT MANUAL 215 and 222 Series PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 Contents Introduction

More information

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER SHOWER CONTROL Installation Operation &B Maintenance Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1 INDEX Page SAFETY WARNINGS 3 ADVICE 3 INTRODUCTION 4 DESCRIPTION 4 PACK CONTENTS 5 DIMENSIONS

More information

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER SHOWER CONTROL Installation Operation &B Maintenance Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1 INDEX Page INTRODUCTION 3 DESCRIPTION 3 SAFETY WARNINGS 4 PACK CONTENTS 5 DIMENSIONS 7 SPECIFICATION

More information

SHOWER FITTINGS. Installation & User Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

SHOWER FITTINGS. Installation & User Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER SHOWER FITTINGS Installation & User Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1 Contents Section Page 1... Introduction... 3 2... Important Safety Information... 4 3... Pack Contents Checklist...

More information

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer 955751.book : t95575.fm Seite 1 Mittwoch, September 20, 2000 10:10 AM Avensys Exposed Single Lever Mixer 33 389 33 396 Installation Instructions and Operating Guide Please leave this document with the

More information

Deluge Optimo Shower valve and kit 10032CP

Deluge Optimo Shower valve and kit 10032CP Deluge Optimo Shower valve and kit 10032CP Installation, Operation and Maintenance Please leave these instructions with the user Intatec Limited Airfield Industrial Estate, Hixon, Staffordshire, ST18 0PF

More information

These instructions are to be left with the user

These instructions are to be left with the user MIRA ENERGISE AND MIRA L10 SHOWER FITTINGS INSTALLATION & USER GUIDE These instructions are to be left with the user 1 CONTENTS Introduction 2 General 2 Design Registration 2 Pack Contents 3 Specifications

More information

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve TMV3 / TMV2 Combined Valve C85079 C85081 C85080 C85082 It is important that these guidance notes are read and fully understood

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions www.reece.com.au Tempering valve 38550.08 5213 series Installation, commissioning and servicing instructions The tempering valve is used to regulate the set temperature of mixed hot and cold water even

More information

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series www.reece.com.au 28255.01 Tempering valve for solar and instantaneous applications 2522HP series Installation, commissioning and servicing instructions The tempering valve is used to regulate the set temperature

More information

These instructions must be left with the user

These instructions must be left with the user Mira Moto, Mira Pace, Mira Minilite and Mira Miniduo ( including Eco Models) Thermostatic Mixers For SPARES, ADVICE or REPAIRS Please call us on 0844 571 5000 (UK Only) These instructions must be left

More information

Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT

Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 CONTENTS Description...3

More information

Scald Protection Three-Way Thermostatic Mixing Valve

Scald Protection Three-Way Thermostatic Mixing Valve CALEFFI www.caleffi.com 383.04 Scald Protection Three-Way Thermostatic Mixing Valve Copyright 00 Caleffi 3 Series Installation, commissioning and servicing instructions Function Scald Protection Three-Way

More information

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3. Product Specification ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.0 bar Latvin Luxury Shower Panel ~ Fixing Centres 150mm +/- 10mm ~ Outlet size 1/2" Bottom Outlet Always maintain a

More information

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces

More information

Engineering Data Sheet

Engineering Data Sheet Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate

More information

Mira Select. Installation & User Guide. These instructions must be left with the user. 1

Mira Select. Installation & User Guide. These instructions must be left with the user. 1 Mira Select Thermostatic Mixer Installation & User Guide These instructions must be left with the user. 1 Contents Introduction 2 Patents and Design Registration 2 Pack Contents 3 Safety Warnings 4 Specifications

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions 38512.08 Tempering valve www.caleffi.com 5213 series Copyright 2018 Caleffi Installation, commissioning and servicing instructions The tempering valve is used to regulate the set temperature of mixed hot

More information

Apricot Kitchen Sink Tap

Apricot Kitchen Sink Tap Apricot Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

Scald Protection 3-Way Thermostatic Mixing Valve

Scald Protection 3-Way Thermostatic Mixing Valve 383.06 www.caleffi.com Scald Protection 3-Way Thermostatic Mixing Valve Copyright 06 Caleffi 3 Series Installation, commissioning and servicing instructions Function Scald Protection Three-Way Thermostatic

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFT LINE CUTTER SL55 PRODUCT CODE No. 980504 INSTRUCTIONS FOR INSTALLATION,

More information

These instructions must be left with the user.

These instructions must be left with the user. Mira Element Thermostatic Mixer Installation and User Guide These instructions must be left with the user. 1 Contents Introduction 2 Guarantee 3 Recommended Usage 3 Patents and Design Registration 3 Safety

More information

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER SHOWER CONTROL Installation Operation &B Maintenance Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER Contents Section Page 1... Introduction... 3 2... Important Safety Information... 4 3... Pack

More information

Installation and User Guide

Installation and User Guide INSTANT I3VS MANUAL ELECTRIC HANDWASH Installation and User Guide IMPORTANT: This booklet should be left with the user after installation and demonstration. THIS APPLIANCE CAN BE USED BY CHILDREN AGED

More information

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web: EZI-DRY Pty Limited ABN: 98 114 507 443 PO Box 370 Phone: 0249711993 Swansea NSW 2281 Fax: 0249135490 AUSTRALIA Mobile: 0427587900 Web: www.ezi-dry.com.au Email: ezidry@exemail.com.au INSTRUCTION MANUAL

More information

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions.  IMPORTANT NOTICE SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5

More information

Horne Engineering Ltd

Horne Engineering Ltd Horne Engineering Ltd Po Box 7, Rankine Street Johnstone, Renfrewshire Scotland, PA5 8BD Tel: 01505 321455 Fax: 01505 336287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE T105A/106A/107A/108A

More information

AREA VALVE SERVICE UNITS

AREA VALVE SERVICE UNITS AREA VALVE SERVICE UNITS. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K., SK3 0SB www.p3-phoenix.com

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

Training. tm PA90 Series - Lung Demand Valve

Training. tm PA90 Series - Lung Demand Valve D Training Dräger tm12842 PA90 Series - Lung Demand Valve Index Section 1 Instructions for Use Section 2 Introduction and Safety Warnings Section 3 Product Description Section 4 Operating Principle Section

More information

PEG402, PEG402UA & PEG402UAX TMV3 / TMV2 Combined

PEG402, PEG402UA & PEG402UAX TMV3 / TMV2 Combined Domestic Valve Solutions Installation Instructions and User Guide 15mm & 22mm In-Line Thermostatic Mixing Valve PEG402, PEG402UA & PEG402UAX TMV3 / TMV2 Combined It is important that these guidance notes

More information

MIRA SELECT THERMOSTATIC MIXER INSTALLATION & USER GUIDE. These instructions must be left with the user. 1. Please call us on (UK Only)

MIRA SELECT THERMOSTATIC MIXER INSTALLATION & USER GUIDE. These instructions must be left with the user. 1. Please call us on (UK Only) For SPARES, ADVICE or REPAIRS Please call us on 0844 571 5000 (UK Only) MIRA SELECT THERMOSTATIC MIXER INSTALLATION & USER GUIDE These instructions must be left with the user. 1 CONTENTS Introduction 2

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

These instructions must be left with the user.

These instructions must be left with the user. MIRA MOTO, MIRA PACE, MIRA MINILITE, AND MIRA MINIDUO ( including Eco models) THERMOSTATIC MIXERS INSTALLATION & USER GUIDE These instructions must be left with the user. 1 CONTENTS Introduction 2 Guarantee

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03 Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure

More information

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections VALVCHEQ Backflow Preventers Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections Features General application The RP03 provides protection from both

More information

Code AWC20HP Air Compressor

Code AWC20HP Air Compressor Code 951816 AWC20HP Air Compressor Index of Contents Index of Contents 02 Declaration of Conformity 02 What s Included 03 Safety Precautions 03 Specifications (AWC20HP Air Compressor) 04 Assembly Instructions

More information

Intamix Thermostatic Mixing Valve

Intamix Thermostatic Mixing Valve Intamix Thermostatic Mixing Valve TMV2 & TMV3 Installation Guide Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF In this procedure document we have endeavoured to make the information

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

12S 1st Stage. -Maintenance Procedure-

12S 1st Stage. -Maintenance Procedure- 12S 1st Stage -Maintenance Procedure- 1 Warning! All maintenance and repair procedures MUST be performed by a Mares authorized Service Center and/or Distributor. Therefore, the information provided below

More information

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER SHOWER CONTROL Installation Operation &B Maintenance Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1 Contents Section Page 1... Important Safety Information... 4 2... Introduction...5 3... Pack

More information

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: 2244025 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

MIRA ELEMENT SLT THERMOSTATIC MIXER INSTALLATION AND USER GUIDE. These instructions must be left with the user.

MIRA ELEMENT SLT THERMOSTATIC MIXER INSTALLATION AND USER GUIDE. These instructions must be left with the user. For SPARES, ADVICE or REPAIRS Please call us on 0844 571 5000 (UK Only) MIRA ELEMENT SLT THERMOSTATIC MIXER INSTALLATION AND USER GUIDE These instructions must be left with the user. 1 CONTENTS Introduction

More information

Installation Instructions and User Guide

Installation Instructions and User Guide Installation Instructions and User Guide 15mm & 22mm In-Line Thermostatic Mixing Valve-TMV2 Model P404 It is important that these guidance notes are read and fully understood prior to product installation

More information

These instructions are to be left with the user

These instructions are to be left with the user MIRA EXCEL SHOWER CONTROL Installation & User Guide These instructions are to be left with the user 1 CONTENTS Introduction... 3 Important Safety Information... 4 Pack Contents Checklist... 5 Dimensions...

More information

Installation Instructions and User Guide

Installation Instructions and User Guide Installation Instructions and User Guide 15mm & 22mm In-Line Thermostatic Mixing Valve-TMV3 Model P402 It is important that these guidance notes are read and fully understood prior to product installation

More information

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions 488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet

More information

MANUAL FOR INSTALLATION, COMMISSIONING AND MAINTENANCE FOR

MANUAL FOR INSTALLATION, COMMISSIONING AND MAINTENANCE FOR MANUAL FOR INSTALLATION, COMMISSIONING AND MAINTENANCE FOR RMC TM THERMOMIX TM 300 25MM THERMOSTATIC MIXING VALVE FOR USE IN AUSTRALIA AND NEW ZEALAND CONTENTS SECTION PAGE NO. 1. INTRODUCTION 2 2. WARRANTY

More information

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913 24L AIR COMPRESSOR MODEL NO: RANGER 7/240 PART NO: 2242000 OPERATION & MAINTENANCE INSTRUCTIONS LS0913 INTRODUCTION Thank you for purchasing this CLARKE 24L Air Compressor. Please read this manual fully

More information

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax aylesbury k valve installation guide For valve sizes (DN): 2 (50)HF 2½ (65)SF 3 (80)RB IMPORTANT Please keep for future reference. PLEASE READ THESE INSTRUCTIONS CAREFULLY AND REFER TO ANY DIAGRAMS BEFORE

More information

ATS430 turbidity sensor Retractable insertion assembly

ATS430 turbidity sensor Retractable insertion assembly A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion

More information

In Line Thermostatic Controller. Copper x Copper

In Line Thermostatic Controller. Copper x Copper In Line Thermostatic Controller. Copper x Copper P404 Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT 15mm P404 1 0 5A1105 5013866078934 89.44 22mm P404 1 0 5A1106 5013866078941 110.08

More information

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015) CHEMICAL INDUCTION KIT (Pt.No.2400-0740 Issue 6, October 2015) DESCRIPTION The C-Dax Chemical Induction Kit is an accessory kit for the GoldLine range of three point linkage sprayers. The system operates

More information

MAINTENANCE PROCEDURE FOR X 650

MAINTENANCE PROCEDURE FOR X 650 MAINTENANCE PROCEDURE FOR X 650 X 650 25. juli 2005-1/6 MAINTENANCE PROCEDURE FOR X 650 2 ND STAGE WARNING: This maintenance procedure is only for appointed Scubapro technicians that completed a course

More information

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , & REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1

More information

CS150 CAP STAPLER OWNER S MANUAL

CS150 CAP STAPLER OWNER S MANUAL Operation Revised 6/2013 www.stingerworld.com CS150 CAP STAPLER OWNER S MANUAL! Maintenance Safety Warranty PLEASE READ! This manual contains important information about product safety. WELCOME TO STINGER

More information

Mainsboost Installation, Operation & Maintenance Instructions

Mainsboost Installation, Operation & Maintenance Instructions mainsboost Mainsboost Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information

More information

WHEATLEY Series 500 Swing Check Valve

WHEATLEY Series 500 Swing Check Valve Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION

More information

Service and Repair Manual

Service and Repair Manual II stage R2 Ice/ Special, II stage R 1 Pro DOWNSTREAM 2 nd STAGE REGULATOR Service and Repair Manual Introduction Safety Precautions...4 General Procedures, Maintenance Schedules...5 Initial Inspection

More information

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115 AIR COMPRESSOR MODEL NO: CHAMP 3 PART NO: 2225222 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Air Compressor. Please read this manual fully before use

More information

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions 1326050/3 IM-P132-11 ST Issue 3 A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation

More information

Installation Instructions

Installation Instructions Installation Instructions COLONY SOFT 7.0 Centerset Lavatory Faucet 7.0 with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a features found

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions 48323 www.caleffi.com Pre-adjustable pressure reducing valve with self-contained cartridge Copyright 2015 Caleffi 5350..H AUS series Installation, commissioning and servicing instructions Function Pressure

More information

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: 2244010 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V Installation and Maintenance Instructions 2 1 MIN MAX 7 In this procedure document we have endeavoured to make the information as accurate as

More information

SERIES-O REGULATOR. Instructions for use

SERIES-O REGULATOR. Instructions for use SERIES-O REGULATOR Instructions for use 522460-05-708 Contents Page 1. INTRODUCTION 2 2. INTENDED USES 3 3. GENERAL DESCRIPTION 4 4. PARTS IDENTIFICATION 5 5. SAFETY PRECAUTIONS 6 6. EQUIPMENT USE 8 7.

More information

TMV20 THERMOSTATIC MIXING VALVE

TMV20 THERMOSTATIC MIXING VALVE TMV20 THERMOSTATIC MIXING VALVE INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL Caroma - TMV 20 - G3/4" Plumbed Assembly Caroma Australia Pty Limited Level 1, 7-9 Irvine Place Norwest Business Park

More information

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing

More information

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01 DUAL CONTROL THERMOSTATIC SHOWER VALVE Shower Control Handles and Concealing Plate may differ depending on choice of Model OWNER S GUIDE ISSUE 01 These instructions cover all exposed or concealed versions

More information

PRESSURISED PAINT CONTAINER

PRESSURISED PAINT CONTAINER PRESSURISED PAINT CONTAINER MODEL NO: CPP2B PART NO: 3082115 OPERATION & MAINTENANCE INSTRUCTIONS GC0913 INTRODUCTION Thank you for purchasing this CLARKE Pressurised Paint Container. Before attempting

More information

4 ANGLE GRINDER MODEL NO: CAT 52 PART

4 ANGLE GRINDER MODEL NO: CAT 52 PART 4 ANGLE GRINDER 4 ANGLE GRINDER MODEL NO: CAT 52 PART No: 3110685 OPERATION & MAINTENANCE INSTRUCTIONS 0807 Fig.1 SPECIFICATIONS Model:...CAG52 Part Number:...3110685 Rated Wheel...Capacity: 4 x 1/4 (type

More information

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X Standard Surge Eliminator Standard 104052 - X Flushable 104053 - X - X Page 2 of 16 Issue: 2.3 Index Section 1.1 General Description 1.2 Operating Principle 1.3 Specification 1.4 Fitting Selection - Standard

More information

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004 EVO Solid Downtube Operators Manual for Downtubes fitted with zinc plated springs June 2004 Read this manual fully before operating the EVO Solid Downtube For all EVO Shearing Plants Head Office 46 Miguel

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

U.KIT2L (Lever Handles) U.KIT2X (Cross Handles)

U.KIT2L (Lever Handles) U.KIT2X (Cross Handles) PERRIN & ROWE EDWARDIAN EXPOSED SHOWER PACKAGE Perrin & Rowe Bath U.KIT2L (Lever Handles) U.KIT2X (Cross Handles) FEATURES Shower package components: - U.5550L or U.5552X - Exposed Therm Mixer - U.5391-40

More information

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE

More information

CUT OFF TOOL MODEL: CAT113

CUT OFF TOOL MODEL: CAT113 CUT OFF TOOL MODEL: CAT113 Part No: 3120135 ASSEMBLY & INSTRUCTION MANUAL LS0309 INTRODUCTION Thank you for purchasing this CLARKE product Before attempting to use the product, it is essential that you

More information

High Performance BSP Dial Up Pattern Pressure Reducing Valve

High Performance BSP Dial Up Pattern Pressure Reducing Valve See our full range online at: www.vip-ltd.co.uk High Performance BSP Dial Up Pattern Pressure Reducing Valve VIP Product Code 31/0103 FUNCTION Pressure reducing valves are devices which, when installed

More information