Dry Plant Measurement Information

Size: px
Start display at page:

Download "Dry Plant Measurement Information"

Transcription

1 Dry Plant Measurement Information Fertilizer - Information Pages DRY PLANT MEASUREMENT Basic Formula: Pounds of Product = Cubic Feet x Product Weight Area A: 14' x 28' x width = cubic feet x product weight Area B: 10' x 6' = 60 square feet 2 = 30 2 x width = cubic feet x product weight Area C: 18' x 6' = 108 square feet 2 = 54 2 x width = cubic feet x product weight Partial Bin Measurement: 10' x 4' = 40 square feet 2 = 20 2 x width = cubic feet x product weight 433

2 Commonly Used Formulas Pressure in PSI of a Column of Water = Height of Column in Feet x.434 Wheel RPM = 1056 x MPH Circumference Gallons per Acre = ( GPM x 5940 ) (GPA) ( MPH x Swath in Inches ) Gallons per Minute = GPA x MPH x Swath in Inches (GPM) 5940 Capacity of a Round Tank in Gallons = Diameters in Inches Squared x Length in Inches x.0034 Gallons per Foot of Depth = Diameter in Feet Squared x Gallons per Foot of Depth = Diameter in Inches Squared x.0408 Diameter of Circle = Circumference x Circumference of Circle = Diameter x Area of Circle = Square of Diameter x.7854 Capacity of a Rectangular Tank in Gallons = Length in Inches x Width in Inches x Height in Inches 231 Fertilizer - Information Pages PRESSURE METRIC MULTIPLY CONVERSION UNITS BY TO OBTAIN Atmospheres Pounds per Square Inch Atmospheres Inches Water Inches of Mercury Feet of Water Inches of Mercury Pounds per Square Inch Inches of Water Inches of Mercury Inches of Water Pounds per Square Foot Inches of Water Pounds per Square Inch Inches of Water Pounds per Square Inch Pounds per Square Inch Atmospheres Pounds per Square Inch Inches of Mercury Pounds per Square Inch Feet of Water Pounds per Square Inch Inches of Water Atmospheres Kilograms per Square Centimeter Grams per Square Centimeter Pounds per Square Inch Kilograms per Square Centimeter Pounds per Square Inch Kilograms per Square Meter Pounds per Square Foot Pounds per Square Inch Kilograms per Square Centimeter LENGTH VOLUME METRIC MISCELLANEOUS Centimeters Feet Feet Feet Inches Inches Kilometer Meters Meters Meters Miles (statute) Miles (nautical) Yards Yards Inches Millimeters Centimeters Meters Millimeters Centimeters Miles Inches Feet Yards Meters Meters Centimeters Meters Cubic Feet 1728 Cubic Inches Cubic Feet Gallons (US) Gallons Cubic Feet Gallons Cubic Inches Gallons (US) Gallons (Imperial) Gallons (Imperial) Gallons (US) Cubic Centimeter Cubic Inch Cubic Feet Liters Gallons (US) Liters Liters Cubic Feet Liters Gallons (US) Liters Quarts (US) Liters Pints (US) Pints (US) Liters BTU Calories Calories BTU Decitherm 10,000 BTU Kilogram Pounds Kilowatt Hour 3412 BTU Ounces Grams Pounds Grams Pounds Kilograms Therm 100,000 BTU 27 Cubic Feet = 1 Cubic Yard FORMULA FOR ACTUAL POUNDS OF NH3 (NITROGEN) PER HOUR Use the Formula: Lbs. Nitrogen x Swath Feet x MPH x.1212 = Nitrogen in One Hour Example: Lbs. of Nitrogen per Acre = 100 Swath Width in Feet = 30 Tractor Speed (MPH) = x 30 x 5 x.1212 = 1818 lbs. per hour This will be the dial setting at 100# tank pressure in a normal fitting arrangement (12 feet hose x hose valve x 1" QDC x 3' of 1" hose). Basic Formula - Pounds of Product: 1 Acre = 16.5' x 2640' (1/2 mile) TRAILER/SPREADER CAPACITY Cubic Feet x Product Weight (to find what equipment will haul) Cubic Feet x Weight of Product 2000 (ton) Example: 38 1/2' Trailer = 1323 Cubic Feet (heaped) 1323 x 46# (Urea) = (ton) = Ton Capacity 434

3 Measurement Conversion Factors GENERAL One Acre One Hectare One Gallon per Acre One Mile One Gallon One Gallon 43,560 Square Feet or Hectares Acres 9.35 Liters per Hectare One Pound per Square Inch (PSI) kg/cm 2 One Pound per Square Inch (PSI) One Pound One Inch AREA MEASURE 144 Square Inches 9 Square Feet 30 1/4 Square Yards 160 Square Rods 1 Acre 640 Acres 1 Square Mile 1 Rod LINEAR MEASURE 12 Inches 3 Feet 5 1/2 Feet 1 Foot 1 Yard 1 Rod 5,280 Feet or 1610 Meters or 1.61 Kilometers 128 Fluid Ounces or 8 Pints or 4 Quarts 3.79 Liters or 0.83 Imperial Gallons kpa (Kilopascal) 454 Kilogram 2.54 Centimeters 1 Square Foot 1 Square Yard 1 Square Rod 1 Acre 43,560 Square Feet 1 Square Mile 1 Section (of Land) 16.5 Feet DRY MEASURE 1/2 Quart 2 Pints 8 Quarts 1 Pint 1 Quart 1 Peck 40 Rods 1 Furlong 4 Pecks 1 Bushels 8 Furlongs 1 Mile 1 Mile 5,280 Feet = 320 Rods LIQUID MEASURE 1/16 Pint 4 Ounces 1 Ounce 1 Gill 105 Quarts CUBIC MEASURE 1,728 Cubic Inches 27 Cubic Feet 1 Barrel 1 Cubic Foot 1 Cubic Yard 4 Gills 1 Pint = 16 Ounces 128 Cubic Feet (4 x 4 x 8 ) 1 Cord (Wood) 2 Pints 1 Quart = 32 Ounces 231 Cubic Inches 1 Gallon 4 Quarts 1 Gallon 31 1/2 Gallons 1 Barrel 31 1/2 Gallons 126 Quarts HEAD 1 Pound per Square Inch (PSI) 1 Foot of Water 1 Inch of Mercury 2,150.4 Cubic Inches 2.31 Feet of Water 2.04 Inch Mercury Pounds per Square Inch Inch Mercury Foot of Water 1 Kilogram per Square centimeter Pounds per Square Inch 1 Atmosphere (at Sea Level) 1 Meter of Water WEIGHT OF SOLUTION 7.0 Pounds per Gallon 8.0 Pounds per Gallon 8.34 Pounds per Gallon Water 9.0 Pounds per Gallon 10.0 Pounds per Gallon 11.0 Pounds per Gallon 12.0 Pounds per Gallon 14.0 Pounds per Gallon 16.0 Pounds per Gallon 18.0 Pounds per Gallon 20.0 Pounds per Gallon Imperial Gallon 14.7 Pounds per Square Inch 33.9 Feet of Water Meters of Water 3.28 Feet of Water SPECIFIC GRAVITY USA Gallons 1 Bushel CONVERSION FACTORS VOLUME 1 US Gallon 1 Imperial Gallon 1 Cubic Foot 1 Liter 1 Cubic Meter 1 Acre Foot 1 Acre Inch 1 Barrel (Oil) METRIC CONVERSION LINEAR MEASURE 1 Centimeter 1 Inch 1 Decimeter 1 Foot 1 Meter 1 Yard 1 Dekameter 1 Rod 1 Kilometer 1 Mile SQUARE MEASURE 1 Square Centimeter 1 Square Inch 1 Square Decimeter 1 Square Foot 1 Square Meter 1 Square Yard 1 Acre 1 Square Rod 1 Hectare 1 Acre 1 Square Kilometer 1 Square Mile MEASURE OF VOLUME 1 Cubic Centimeter 1 Cubic Inch 1 Cubic Decimeter 1 Cubic Foot 1 Cubic Yard 1 Stere 1 Cord 1 Liter 1 Quart Dry 1 Quart Liquid 1 Dekaliter 1 Gallon 1 Peck 1 Hektoliter 1 Bushel WEIGHTS 1 Gram 1 Ounce 1 Kilogram 1 Pound 1 Metric Ton 1 English Ton 231 Cubic Inches Cubic Feet Liters Cubic Meters Imperial Gallon 1.2 US Gallons Cubic Inches 1728 Cubic Inches US Gallons Cubic Meter US Gallon Cubic Feet US Gallons 43,560 Cubic Feet 325,829 US Gallons 3,630 Cubic Feet 27,100 US Gallons 42 US Gallons Inches 2.54 Centimeters Inches or Feet Decimeters Inches or Yards Meter Rods Dekameter Mile Kilometers Square Inch Square Centimeters Square Foot Square Decimeter Yards Square Meter 160 Square Rods Acre 2.47 Acres Hectare Square Mile 2.59 Square Kilometers Cubic Inch Cubic Centimeters Cubic Foot Cubic Decimeters Cubic Meter Cord Steres Quart Dry or Quarts Liquid Liters Liter Gallons or Pecks Dekaliter Dekaliter Bushels Hektoliter Ounce Grams Pounds Kilogram English Ton Metric Ton Fertilizer - Information Pages 435

4 NH3 CFM Chart and Properties Fertilizer - Information Pages 436

5 FEI, Inc. Valves Quality Steel Tank Corporation Tank Specifications Emergency Shutoff NH3 Hardened Threads The 2" FNPT threads on the nipple portion are of hardened stainless steel to reduce wear from repeated use. Excess Flow Valve With a poppet design similar to the internal valve series, an excess flow spring is available. The spring has a closing flow of 200 GPM propane at 13 psid. Dual Service With all internal parts either stainless steel or plated steel, the valve can be used on NH3 service as well as LP gas. Marshall Excelsior Safety Stroke ME551 is constructed with durable, corrosion resistant stainless steel and is a perfect fit for the Fisher N550 series and is designed to fit all ESV sizes. It features the Airstroke actuator by Firestone with smooth acting cam and heavy return spring allowing complete opening for full flow. It is easy to install without modification with a temperature range of -60º F. to 250º F. and recommended operating pressure of psig. DESCRIPTION VALVE-EMER SHUTOFF 1-1/4" FPT 50 GPM SNAPPY JOE VALVE-EMER SHUTOFF 2" FPT 75 GPM SNAPPY JOE VALVE-EMER SHUTOFF 3" FPT 195 GPM SNAPPY JOE RELEASE-CABLE FOR N550 ESV VALVE 50' LONG KIT-AIR CYL N550 VALVE CLOSE ONLY KIT-AIR CYL OPEN & CLOSE SPRING-EXTERNAL CLOSING FOR N550 ESV VALVES VALVE-EMER SHUTOFF 2" FPT X 3-1/4" MPT RR TANK CARS ACTUATOR-EMER SHUTOFF N550 ESV VALVES LIST PRICE $ $1, $2, $ $ $ $ $3, $ Remote Shutdown Safely shuts down all valves from 300 feet away in any direction. Works with electric or pneumatic ESV and internal valves. Apply to existing or pneumatic systems with minimal installation. Works with any pneumatic brand actuator eliminating unreliable cable pull systems. Operate up to 15 RSD-E1 transmitters per E-Box. Transmitters are programmable for multiple facility sites. RSD E-Box is ready to go with 110 Volts in and 12 Volts out and includes one RSD-E1 transmitter. PART NUMBER RSD-E1 RSD-E-BOX RSD-SVH-AA DESCRIPTION TRANSMITTER-REMOTE RECEIVER-STORAGE REMOTE SHUTDOWN MODULE-PNEUMATIC SOLENOID VALV LIST PRICE $ $4, $ Fertilizer - NH3 Pages Fertilizer - Information PART NUMBER LP-N LP-N LP-N LP-P164B LP-P327D LP-P539 LP-P551 LP-N LP-ME551

6 Trinity Containers NH3 Tank Specifications Fertilizer - Information Pages 438

7 hes NOTES

8 hes NOTES

9 hes NOTES

10 hes NOTES

11

12 FEI, Inc. Valves Emergency Shutoff NH3 Snappy Joe Emergency Shutoff Valves for Bulk Plants - Snappy Joe type N551 emergency shutoff valves are designed for in-line installations, usually near a bulkhead. The valves provide a means of shutting off gas in the event of a hose rupture or piping break at the transfer area to avoid a large scale loss of LP gas or NH3. The valves can be manually opened and closed at the installed location or closed remotely by either cable or air. A remote operating actuator is also available. High Flow Capacity The main poppet moves completely out of the flow stream for extremely low restriction to flow. Fertilizer - NH3 Operational Ease Moving the operating lever to the vertical position opens the valve, making it simple to tell if the unit is open or closed. A pilot valve in the poppet opens as the lever is moved upward to pressurize the hose. Once equalized, the poppet moves quickly to the open position. The valve is closed by simply pushing the lever down without first having to trip a latch. The operating lever is easily reached from across a bulkhead. All sizes look similar and operate exactly the same, an important point in an emergency situation. Type P164B a release assembly that uses 50 feet (15 meters) of cable housing which does not require elaborate guiding like uncovered cables. Pneumatic Operation Remote pneumatic closure is available with type P327D release. Depending upon valve inlet pressure, a minimum supply pressure of 30 to 70 psig (2,1 to 4,8 bar) on the P327D allows the valve to be latched in the open position with manual closure possible at the valve. Loss of supply pressure to the cylinder permits the ESV to close. Air, nitrogen or CO2 can be used for the cylinder supply source. Maximum inlet pressure to the cylinder is 125 psig (8,6 bar). Operating temperature range -40º F to 212º F (-40º C to 100º C). Type 539 pneumatic actuator permits opening and closing of the N550 Snappy Joe emergency shutoff valves (ESVs) both at the valve with the use of a pneumatic four way valve and from a remote location. The actuator opens the valve when pressure is applied. Minimum pressure is 20 psig (1,4 bar) and maximum pressure is 30 psig (2,1 bar). Upon loss of pressure, the N550 closes, assisted by the spring in the pneumatic actuator. Snappy Joe Emergency Shutoff Valves for Railroad Tank Cars - Snappy Joe type N562 Emergency Shut off Valves (ESVs) are designed for railcar protection and attach to the shutoff valves on railroad tank cars (refer to installation drawing). Typically three N562s are used two on the liquid lines and one on the vapor line. NFPA 58 regulations call for ESV protection on both sides of the transfer hose or piping. Pneumatically operated, the valve is opened and closed by means of a standard quick disconnect coupling (furnished). Approximately 20 to 60 psig (1,4 to 4,1 bar) is needed to open the valve, depending upon tank car pressure. 128

13 FEI FAX ORDER FORM FAX % Fax Order Discount DATE: FEI ORDER NO.: BILL TO: SHIP TO: ZIP CODE: ZIP CODE: CUSTOMER NAME: SHIP TO NAME: ADDRESS: ADDRESS: TOWN: TOWN: CONTACT PERSON: PURCHASE ORDER # PHONE: SHIP VIA: COMMENTS: UPS GROUND CPU SPEEDEE PARCEL POST MOTOR FREIGHT OTHER QUANTITY PART NUMBER DESCRIPTION BILLINGS, MT ( ) HASTINGS, NE ( ) VALLEY CITY, ND ( ) YAKIMA, WA ( )

14 THE PRODUCTS, KNOWLEDGE, AND EXPERIENCE TO SERVE YOUR NEEDS WITH THE BRANDS YOU KNOW AND TRUST Liquid Handling Products WCCO Belting, Inc. NEW LOCATION - HASTINGS, NEBRASKA Phone: (800) Fax: (800)

Minutes of the Meeting. BE IT RESOLVED, Affirmed American National, Peter McHenry Ackermann, claimed his private property, known as a vote.

Minutes of the Meeting. BE IT RESOLVED, Affirmed American National, Peter McHenry Ackermann, claimed his private property, known as a vote. The office of the Secretary of State for The United States of America Office hours: 9 A.M- 8:30 P.M. Monday Friday Phone: 1-951-389-0313 Email: secretaryofstatefortusa@generalpost.org Letterhead for International

More information

Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements

Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements May 2005 Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements D450143T012 R www.fisherregulators.com/lp Table of Contents Table of Contents............................................................

More information

MEASUREMENTS LAND LINEAR MEASURE... 2 LAND AREA MEASURE... 3 VOLUME MEASURE WEIGHT or MASS... 5 MEASURES OF ANGLES AND ARCS...

MEASUREMENTS LAND LINEAR MEASURE... 2 LAND AREA MEASURE... 3 VOLUME MEASURE WEIGHT or MASS... 5 MEASURES OF ANGLES AND ARCS... MEASUREMENTS LAND LINEAR MEASURE... 2 LAND AREA MEASURE... 3 VOLUME MEASURE... 4 WEIGHT or MASS... 5 MEASURES OF ANGLES AND ARCS... 6 AREAS AND VOLUME CALCULATIONS... 6 1 Imperial/US measurements LAND

More information

Estimating Highway Maintenance Work 2008

Estimating Highway Maintenance Work 2008 Purdue University Purdue e-pubs Indiana Local Technical Assistance Program (LTAP) Publications Indiana Local Technical Assistance Program (LTAP) 5-2008 Estimating Highway Maintenance Work 2008 Ohio Department

More information

PART 3 MODULE 6 GEOMETRY: UNITS OF GEOMETRIC MEASURE

PART 3 MODULE 6 GEOMETRY: UNITS OF GEOMETRIC MEASURE PART 3 MODULE 6 GEOMETRY: UNITS OF GEOMETRIC MEASURE LINEAR MEASURE In geometry, linear measure is the measure of distance. For instance, lengths, heights, and widths of geometric figures are distances,

More information

The Right Tool for the Job

The Right Tool for the Job 65 The Right Tool for the Job Tool yardstick, meterstick, inch ruler, odometer, pan balance, measuring cup, metric ruler, scale, eyedropper Unit inch, gram, ounce, centimeter, foot, kilogram, pound, mile,

More information

c) How much will Carrie pay for flooring her room that is 16ft by 20ft if flooring costs $12.95 / square yd? Area of room: 16 20

c) How much will Carrie pay for flooring her room that is 16ft by 20ft if flooring costs $12.95 / square yd? Area of room: 16 20 Course: MFM2P Gr. 10 Applied Lesson: 1-2 Unit: Measurement Systems and Similar Triangles Topic: Measure homework check: Lesson 1-1 note: Measure The metric system is Canada s official measurement system

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

DEPARTMENT OF THE ARMY TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS LIST

DEPARTMENT OF THE ARMY TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS LIST TM 9-4940-428-14 & P DEPARTMENT OF THE ARMY TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS LIST FOR SPRAY OUTFIT, PAINT, MODEL 50-6519

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Chapter 5 Rate, Ratio and Proportion

Chapter 5 Rate, Ratio and Proportion Chapter 5 Rate, Ratio and Proportion Contents Chapter 5 Rate, Ratio and Proportion... 1 Introduction to Rates and Ratios... 3 Unit Prices Internet Activity... 4 Solving Proportion Problems... 5 Converting

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

Convert Units of Length

Convert Units of Length Lesson 6. Convert Units of Length To convert a unit of measure, multiply by a conversion factor. A conversion factor is a rate in which the two quantities are equal, but are expressed in different units.

More information

Section 2.3: Conversions Factors and Unit Rates

Section 2.3: Conversions Factors and Unit Rates CHAPTER 2 CLASS NOTES Name Period Date Metric (International) Units: s 1 s 1 kilometer meters 1 meter decimeters 1 meter centimeters 1 meter millimeters These conversions are also true for grams and liters.

More information

Application Worksheet

Application Worksheet Application Worksheet All dimensions are nominal. Dimensions in [ ] are in millimeters. Service Conditions Medium Through Valve: Required C v : Temperature Maximum: Minimum: Normal: Flow Maximum: Minimum:

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings BR-G-REG-13-30-03-02-A* 461-S, 461-8S and 461-12S Regulators Brochure Introduction The Sensus Models 461-S, 461-8S and 461-12S are balanced valve, spring type regulators designed for distribution and industrial

More information

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE 1 of 10 1. DESCRIPTION (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system

More information

Math 15 Test 3 Review Section Change 4.5 yards to inches. Round your answer to the nearest inch. (1 yd = 3 ft, 1 ft = 12 in)

Math 15 Test 3 Review Section Change 4.5 yards to inches. Round your answer to the nearest inch. (1 yd = 3 ft, 1 ft = 12 in) Page 1 Math 15 Section 6.3 18. Change 4.5 yards to inches. Round your answer to the nearest inch. (1 yd = 3 ft, 1 ft = 12 in) 30. Change 528 inches to feet. (1 ft = 12 in) 42. Change 3 1/16 pounds to ounces.

More information

Medium Heavy Vehicle Safety and Foundation 1

Medium Heavy Vehicle Safety and Foundation 1 Medium Heavy Vehicle Safety and Foundation Student/intern information: Name Class Vehicle used for this activity: Year Make Model Odometer VIN Learning Objective / Task General Safety Identify tools and

More information

Customary Units of Length

Customary Units of Length Lesson 12.1 Name Measurement Benchmarks You can use benchmarks to estimate measurements. The chart shows benchmarks for customary units of measurement. Benchmarks for Some Customary Units CUP 1 ft 1 foot

More information

DESIGN DATA. Dry 105a. September 5, 2008

DESIGN DATA. Dry 105a. September 5, 2008 September 5, 2008 Dry 105a 1. Description Dry and Preaction Systems require a dependable source of clean dry air under the proper pressure. The air supply must be adequate to restore normal air pressure

More information

Unit Rates and Conversions

Unit Rates and Conversions I. Converting Within Systems A. Complete each customary measurement conversion. 1. There are 4 quarts in 1 gallon. How many quarts are in 4 gallons? 2. There are 16 ounces in 1 pound. How many pounds are

More information

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls Type 1098-EGR and Type 1098H-EGR VL1000 FIELDVUE Pilot-Operated Valve Link Regulators Fisher Controls January 1982 Bulletin The Type 1098-EGR and Type 1098H-EGR regulators (figure 1) provide economical

More information

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction. Bulletin 335 Model DDX-LP Dry Pipe Valve System 8 (200mm) Bulletin 335 Features 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Differential latching clapper-type, lighweight, dependable construction. Low Air Pressurized

More information

Data Sheet Issue A

Data Sheet Issue A Features 1. Differential latching clappertype, lighweight, dependable construction. 2. Low Air Pressurized System, 8 psi -to- 26 psi (0,6 bar to- 1,8 bar) 3. Reset externally. Cover removal is not required.

More information

Jenny Castillo Tammy Muller Brandi Stemple. Intro to Physical Science Fall 2010 Dianne Phillips

Jenny Castillo Tammy Muller Brandi Stemple. Intro to Physical Science Fall 2010 Dianne Phillips Jenny Castillo Tammy Muller Brandi Stemple Intro to Physical Science Fall 2010 Dianne Phillips History of the English System The measurement system commonly used in the United States today is nearly the

More information

Lesson 12.1 Skills Practice

Lesson 12.1 Skills Practice Lesson 12.1 Skills Practice Name Date Customary to Whom? Customary Measurement Vocabulary Match each definition to its corresponding term. 1. to change a measurement to an equivalent measurement in different

More information

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Features 1. 2. 3. 4. 5. 6. 7. 8. 9. Differential-type valve, lightweight, dependable construction.

More information

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For

More information

USEFUL RELATIONSHIPS

USEFUL RELATIONSHIPS Use the chart below for the homework problems in this section. USEFUL RELATIONSHIPS U.S. Customary 12 in. = 1 ft 3 ft = 1 yd 280 ft = 1 mi 16 oz = 1 lb 2000 lbs = 1 T 8 fl oz = 1 c 2 c = 1 pt 2 pts = 1

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity VERVIEW This valve sizing software program is based on the use of nomenclature and sizing equations from ISA Standard S75.01 and IEC Standard 534-2. The sizing equations are based on equations for predicting

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Model 1800 PFM Series Regulator. Technical Bulletin

Model 1800 PFM Series Regulator. Technical Bulletin Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane

More information

A.M. The time between 12:00 midnight and 12:00 noon. Houghton Mifflin Co. 1 Grade 4 Unit 5

A.M. The time between 12:00 midnight and 12:00 noon. Houghton Mifflin Co. 1 Grade 4 Unit 5 A.M. The time between 12:00 midnight and 12:00 noon. Houghton Mifflin Co. 1 Grade 4 Unit 5 bar graph A graph in which information is shown by means of rectangular bars. Favorite Sea Creature Sea Creature

More information

Model: AT-1000 L.P.G. FREEZE VALVE

Model: AT-1000 L.P.G. FREEZE VALVE Model: AT-1000 P/N: 2156006200 3829 Forest Parkway Suite 500 Wheatfield, NY 14120-3763 Phone: 716-629-3802 Fax: 716-693-9162 solutions@viatran.com www.viatran.com 1 OPERATION AND MAINTENANCE INSTRUCTIONS

More information

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators July 2008 Differential as low as 1 psid (70 mbar d) Materials of Construction Compatible with Below Grade Installations Quick Change Trim Package

More information

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Product Code No. LIT-12011515 Issued June 19, 2009 The V248 Series 3-Way Pressure-Actuated Water-Regulating Valves

More information

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7 TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7 March 2014 Form FVC097 - Rev03 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER.

More information

Choosing the right miniature instrument and control valve is a snap

Choosing the right miniature instrument and control valve is a snap Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction

More information

Gas Hydraulic Valve Operator

Gas Hydraulic Valve Operator A L o ng E xper ience in Energy Equipmen t and One G o al: T he C u sto mer s Sa tisfa c tion Gas Hydraulic Valve Operator Rugged, reliable controls are at the heart of any good actuator. In the pipeline

More information

CONTINENTAL NH3 PRODUCTS PRODUCT CATALOG

CONTINENTAL NH3 PRODUCTS PRODUCT CATALOG PRODUCT CATALOG October 2012 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Continental NH3 Products A-360 MANIFOLD ORDERING INFORMATION Thank you for ordering our new A-360 manifold system. To assist in

More information

GAS SUPPLY DESIGN GUIDE

GAS SUPPLY DESIGN GUIDE GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14

More information

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271 RED DOT UNITS Controls Water & Air PAGE 271 AIR SWITCHES AND CYLINDERS 72R000 Normally Closed, Opens at 2 PSIG 1 8-27 NPTF Male AIR SENSING SWITCHES RD--447-0P 72R0070 Normally Open, Closes at 21 TO 29

More information

Model: AT-1000 L.P.G. FREEZE VALVE

Model: AT-1000 L.P.G. FREEZE VALVE Model: AT-1000 P/N: 2156006200 3829 Forest Parkway Suite 500 Wheatfield, NY 14120-3763 Phone: 716-629-3802 Fax: 716-693-9162 solutions@viatran.com www.viatran.com 1 OPERATION AND MAINTENANCE INSTRUCTIONS

More information

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual 10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured

More information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven 4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...

More information

Full Service Warehouse

Full Service Warehouse DIRECT FAX (320) 235-1816 110 19th Street NW P.O. Box 1178 Willmar, Minnesota 56201 (320) 235-4070 1-800-992-8853 1-800-328-8994 Full Service Warehouse 3-D LASER SHEARING BREAKING FLAME CUTTING PLASMA

More information

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343 RED DOT UNITS Controls Water & Air PAGE 343 AIR SWITCHES AND CYLINDERS 72R000 Normally Closed, Opens at 2 PSIG 1 8-27 NPTF Male AIR SENSING SWITCHES RD--447-0P 72R0070 Normally Open, Closes at 21 TO 29

More information

Mathematics in Contemporary Society Chapter 9

Mathematics in Contemporary Society Chapter 9 City University of New York (CUNY) CUNY Academic Works Open Educational Resources Queensborough Community College Fall 2015 Mathematics in Contemporary Society Chapter 9 Patrick J. Wallach Queensborough

More information

Powers Controls RC 195 Multiple Input Receiver- Controller

Powers Controls RC 195 Multiple Input Receiver- Controller Powers Controls RC 195 Multiple Input Receiver- Controller Document No. 155-036P25 RC 195-1 Description Features Application The RC 195 Multiple lnput Receiver-Controller is a pneumatic instrument which

More information

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves Types ACE95 and ACE95Sr Tank Blanketing Valves Bulletin 74.1:ACE95 May 2010 W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot

More information

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection February 9, 1998 Foam 201a 1. DESCRIPTION A Deluge Bladder Tank Foam/Water System is a standard deluge system capable of discharging a foam/water solution automatically through open sprinklers, spray nozzles,

More information

Type ACE95jr Tank Blanketing Valve

Type ACE95jr Tank Blanketing Valve Type ACE95jr Tank Blanketing Valve Features Fully Balanced Plug Design Reduces Inlet Pressure Sensitivity Bulletin 74.1:ACE95JR May 2010 Stainless Steel Construction Available High Sensitivity Self-Contained

More information

SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK

SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK SIZING THE EXTROL DIAPHRAGM-TYPE HYDRO-PNEUMATIC TANK 1400 Division Road, West Warwick, RI 02893 T: 401.884.6300 F: 401.885.2567 www.amtrol.com Sizing the ExTrol Diaphragm-Type Hydro-Pneumatic Tank For

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is adopted as part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following factors must

More information

The Hoffman Specialty Series 2000 consists of main

The Hoffman Specialty Series 2000 consists of main Pressure and/or Temperature Pilot Operated Steam Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They are designed to meet a wide range of

More information

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL. SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG

More information

Type R622 Pressure Reducing Regulator

Type R622 Pressure Reducing Regulator Type R622 Pressure Reducing Regulator June 2010 Compact Design Protective Inlet Screen High Capacity Internal Relief Light Weight W8806 Inlet and Outlet Pressure Gauge Taps Figure 1. Type R622 Pressure

More information

Instruction Manual VCG-6

Instruction Manual VCG-6 Specifications Amps / Volts requirements 400 ma @ 24 VDC Propane pressure (VCG-6LP) 11 WC / 2.8 kpa Natural Gas pressure (VCG-6NG) 4.5 WC / 1.15 kpa Cu ft per hour / CO2 3-6 SCFH BTU Rating (Variable)

More information

Full Internal Relief Valves Instruction Manual

Full Internal Relief Valves Instruction Manual Full Internal Relief Valves Instruction Manual MEV200FIR & MEV300FIR Application: Designed for use in mobile LPG & NH 3 containers as a primary pressure relief valve for bobtail and transport trailer installations.

More information

Year 9 notes part 5. Contents

Year 9 notes part 5. Contents Year 9 notes part 5 nb: In lessons we leave imperial and compound units until after the area and volume calculations. For ease of revision, I have included all the unit material here and put the area and

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

Before we begin, let us recall some important information about the metric measuring system.

Before we begin, let us recall some important information about the metric measuring system. Before we begin, let us recall some important information about the metric measuring system. To convert from a larger to smaller metric unit you always multiply. To convert from a smaller to larger unit

More information

ENGINEERING DATA. Engineering Data

ENGINEERING DATA. Engineering Data ENGINEERING DATA Engeerg Data 599 Average Depth 3.5 ft. ESTIMATING TOTAL GALLONS IN A POOL OR SPA Length 24 ft. Dia. Width Depth (deep) Depth (shallow) Radius 2 x 3.14 x A.D. x 7.5 = Gallons 12 x 12 x

More information

Build Your Own Flamethrower Step-by-step Manual

Build Your Own Flamethrower Step-by-step Manual Build Your Own Flamethrower Step-by-step Manual Table of Contents: Parts List.. page 1 Operation...page 6 Diagrams. pages 7-9 Parts list: Required: Air tank (large) Pressure washer gun with high-pressure

More information

T208VR Series Tank Blanketing Vacuum Regulator

T208VR Series Tank Blanketing Vacuum Regulator February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease

More information

Quick Reference Technical Data

Quick Reference Technical Data Bulletin 127C 2 Quick Reference Technical Data For over 100 years, The Spencer Turbine Company has specialized in innovative solutions to air and gas handling problems. Spencer's product line includes

More information

Limited quantities of compressed gases.

Limited quantities of compressed gases. 173.306 Limited quantities of compressed gases. (a) Limited quantities of compressed gases for which exceptions are permitted as noted by reference to this section in 172.101 of this subchapter are excepted

More information

MEGR-1912 Instruction Manual

MEGR-1912 Instruction Manual MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

LP-10 LP-GAS SERVICEMAN'S HANDBOOK

LP-10 LP-GAS SERVICEMAN'S HANDBOOK LP-10 LP-GAS SERVICEMAN'S HANDBOOK The Fisher Controls LP-Gas Serviceman's Handbook serves as a general reference of information on LP-Gas and for the installation, operation and maintenance of LP-Gas

More information

UNIT PLAN. Grade Level: 3 Unit #: 4-2 Measurement: Length, Volume, Mass, & Equivalencies

UNIT PLAN. Grade Level: 3 Unit #: 4-2 Measurement: Length, Volume, Mass, & Equivalencies UNIT PLAN Grade Level: 3 Unit #: 4-2 Unit Name Measurement: Length, Volume, Mass, & Equivalencies Big Idea/Theme: Measurement is used to effectively communicate a common language of numerical information.

More information

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators January 2016 Differential as low as 1 psi / 70 mbar Materials of Construction Compatible with Below Grade Installations Quick Change Trim Package

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code. This appendix is an excerpt from the 2003 International Fuel Gas Code, coordinated with

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome

More information

LESSON 9 - PRACTICE PROBLEMS

LESSON 9 - PRACTICE PROBLEMS LESSON 9 - PRACTICE PROBLEMS 1. Complete each of the following showing as much work as possible. a. Does it take more cups or gallons to measure the amount of water in a large pot? Explain. b. The lifespan

More information

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically

More information

Data Sheet Issue A

Data Sheet Issue A Features 1. Differential-type valve, lightweight, dependable construction. 2. Low Air Pressurized System, 10 psi -to- 26 psi (0,7 bar -to- 1,8 bar). 3. Reset externally.cover removal is not required. 4.

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes DS-G-REG-13-43-0812-01-A* Model 243-RPC Pilot Operated Regulators Installation and Maintenance Instructions Rugged, Reliable with Value-added Features Genuine, pilot-operated regulators use the same relay

More information

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance CVI Valve Line Exceeds the industry s highest standards for reliability and performance Available in the most standard models with the shortest lead times in the industry Exceptional quality every CVI

More information

Series 100 Slam Shut Valve. Technical Bulletin

Series 100 Slam Shut Valve. Technical Bulletin Series 100 Slam Shut Valve Technical Bulletin 02 Elster The Series 100 Slam Shut protects gas installations against overpressure conditions by automatically shutting off the gas flow. General Information

More information

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2. 1.26. A certain object weighs 300 N at the earth's surface. Determine the mass of the object (in kilograms) and its weight (in newtons) when located on a planet with an acceleration of gravity equal to

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS INSTALLER! PLEASE LEAVE WITH HOMEOWNER INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS by Please Note: It is important that you read instructions before installing or operating gas logs

More information

Global Connection Solutions for Local Industrial Fluid Applications

Global Connection Solutions for Local Industrial Fluid Applications Global Connection Solutions for Local Industrial Fluid Applications Legris offers world wide subsidiaries, production centers and a distribution network Get connected with Legris on the North and Central

More information

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

Pneumatic Reservoir Analysis Work Sheet

Pneumatic Reservoir Analysis Work Sheet Pneumatic Reservoir Analysis Work Sheet Getting Started Use a pair of dial calipers to measure the length and diameter dimensions of the: 1. End Cap 2. Threaded Boss 3. Stainless Steel Tube Record these

More information

Natural Gas Conversion Kit

Natural Gas Conversion Kit SERIAL #: Attention: Centro recommends that a qualified gas technician perform the gas supply conversion and orifice replacement for this BBQ model. Natural Gas Conversion Kit F O R U S E W I T H M O D

More information

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270 SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP Simple Inexpensive Foam Proportioner Portable Inlet Pressure Choices 90 to 200 PSI Foam Rate 44 GPM to 362 GPM Salt Water Compatible Special Flow And Pressure

More information