1 FOSC-400B4-MC-X06-X-NV I N S T A L L A T I O N I N S T R U C T I O N Fiber Optic Splice Closure with integrated Organizer System for modular Cable Contents 1 Introduction 1.1 Product description 1.2 Port capacity 1.3 Tray capacity 2 General 2.1 Kit content 2.2 Tools 2.3 Accessories 3 Installation 3.1 Closure preparation 3.2 Installation of multiduct(s) into the port 3.3 Installation of microcable directly into the port A. Oval port B. Drop ports 3.4 Sealing of the oval port 3.5 Sealing of the round (drop) port A. Single multiducts entries B. Multiple multiducts entries 3.6 Microduct preparation 3.7 Termination and routing of the fibers A Oval port (10 mm microducts) B Drop ports (5 mm microducts) 3.8 Splicing and fiber storage 3.9 Closing the closure 4 Grounding/shielding 5 Re-entry 6 Inter tray jumping 7 General precautions 8 Mounting kit 1 Introduction 1.1 Product description This installation instruction describes the necessary installation steps to install the FOSC-400B4-MC product. The product has the capability to install microcable directly into the ports or multiducts. It can accommodate different types of trays. It has one oval entry port, which can handle 2 microcables or multiducts and 4-drop ports. It is recommended to install the cable seals with hot air (hot air should be at least 350 C). The FOSC-400 can be installed in: direct buried, manholes or aerial locations. Follow the local safety guidelines during installation.
2 1.2 Port capacity Capacity Multiduct Outside Oval port Drop port Diameter (D=19 mm) 1x5 mm 7.1 NA 2* 2x5 mm 13x8 NA 2* 4x5 mm 15.2 NA 1 7x5 mm 18.6 NA 1 12x5 mm 24 NA 0 19x5 mm 29.6 NA Tools Marking pen FACC-TUBE-CUTTER-01 FACC-TUBE-CUTTER-MC Accessories 1x10 mm NA 2x10 mm 22x12 2 NA 4x10 mm 27 0 NA 7x10 mm 35 0 NA * sealing of multiples is done with the standard sealing kit and SCOP (see section 3.5B). 1.3 Tray capacity Fiber storage length X(Y) with X fibre storage length (mm) on both sides of smouv and (Y) maximum number of splices Tray type 250/ / /900 FOSC-AS-TRAY-S6/A6* 1200(6) 1200(4) 1200(2) Microduct connectors Tyco reference: FACC-MC-ECAP-10MM-10 FACC-MC-ECAP-5MM-10 FACC-MC-BCON-10MM-10 FACC-MC-BCON-5MM-10 FACC-MC-EBLOCK-5MM Supplementary tray kit(s) can be ordered: see ordering guide * When A6 tray is used (use of ANT splice protectors). Only 250/250 column is applicable. 2 General 2.1 Kit content SCOP to seal multiple cable entries in drop ports. Tyco reference: FACC-MC-SCOP-CS Installation 3.1 Closure preparation Dome Base with basket and organizer Velcro and wedge Clamp O-ring Silicagel Transportation tubes Strength member terminations Oval seal kit Loose buffer tubes storage bag Loose the clamp. Push the lever down to release the locking tab. Open the clamp lever and release the clamp using the lever legs. Remove the clamp, dome and sealing ring and store carefully for later use. 2
3 3.1.2 Install the FOSC in the FOSC-STAND Position the jacket end halfway (± 30 mm) in the port and secure the microducts into the closure with tape. One can also secure the multiducts at the outside of the closure. Note: securing the microducts (multiducts) prevent the multiduct from moving out of the closure when installing the sleeve. Check the port capacity table (point 1.2) for the allowed configurations The above drawing shows the positioning of 2*2w10mm multiducts in the oval port Continue with section 3.4 or Open the appropriate port at the ridge; the cutting wire can be used. 3.2 Installation of multiduct(s) into the port 3.3 Installation of microcable directly into the port Remove the microcable jacket over a distance of : - loop cable; 4 meter - cable ends; 2 meter Clean the loose buffer tubes and cut the strength members at : Oval port entry: 60 mm Drop port entry: 100 mm. A Oval port Clean the multiduct jacket over a distance of 2 meters with a clean cloth.remove the outer-jacket over a distance of 300 mm. Note: in case of multiple multiducts in a round (drop) port, continue with section 3.5B. Make sure the microduct is not damaged Slide the cable seal over the multiduct(s). Note: make sure the arrow on the seal sleeve (uncoated zone) is pointing towards the base Slide the cable seal over the microcables. Insert the microcables thru the oval port. Note: make sure the un-coated zone (arrow on the cable seal) is pointing towards the base of the closure. 3
4 B Drop ports Microcables directly installed thru the drop port are sealed with the kit: - FIST-GCO2-RSK-16-MC. Note: when multiple cables per port are required, the kit FIST-GCO2/16-MU-2/2-6 can be used together with FIST-GCO2-RSK-16-MC Make sure one has minimum 2 m of microcable inside the closure Remove the microcable jacket at 70 mm of the bottom of the base Secure the strength member connectors into the closure, secure the strength members into the strength member connector. Note: avoid crossings of loose buffer tubes and strength members, two strength members can be cut if necessary Continue with point Sealing of the oval port Clean and abrade the port and the microcable Thoroughly clean oval port and multiducts with the cleaning tissue over a distance of 150 mm from the edge of the port. Note: in case the microcable was entered directly into the port, a SCOP is already installed around the microcable. Cleaning the microcable is not necessary anymore at this point Install a SCOP around each cable (FACC-MC-SCOP-CS-10). Position the SCOP directly underneath the oval port Continue with section 3.4 (sealing of the oval port) Abrade oval port and multiducts circumferentially on the cleaned area with the abrasive strip. Note: in case the microcable was entered directly into the port, a SCOP is already installed around the microcable. Abrading the microcable is not necessary anymore at this point. 4
5 3.4.3 Place the oval seal over the oval port and the multiducts. When the seal butts against the base, mark the sleeve length onto the multiducts Slide the cable seal over the port. Install the branch-off clip. Check that the heat-shrinkable cable seal butts up against the base and the branch-off clip is completely inserted. Tape the two multiducts together Shrink the cable seal on the base side with the recommended hot air gun device with reflector. Shrink sleeve until the green thermoindicating paint is converted to black. (Make sure the hot-air temperature is at least 350 C). (If a FACC-HEAT-GUN-220V is used, set position on scale 10) Match the blue line of the aluminum cable protection foil with the marks on the multiducts. Wrap aluminum cable protection foil around the multiducts. Note: in case of microcables directly into the port (section 3.3), disregard the blue line and place the aluminum protection foil only 15 mm to the inside of the mark (end of seal) Shrink down the end of the cable seal on the multiduct side. Heat until the sleeve shrinks down on the multiducts and make sure that the green thermo-indicating paint is converted to black. Postheat the clip on both sides till the adhesive shows a proper flow on the clip. Do not move the closure or multiducts (microcables) during 20 mm. 5
6 3.5 Sealing of the round (drop) port A Single multiduct entries Thoroughly clean the port and the multiducts with the cleaning tissue over a distance of 150 mm from the edge of the port Match the blue line of the aluminum cable protection foil with the mark on the multiduct. Wrap the aluminum cable protection foil around the multiduct Abrade the port and the multiducts circumferentially on the cleaned area with the abrasive strip Slide the seal over the port. Shrink the seal on the base side with the recommended hot air gun device. Use the reflector to ensure heat distribution around the outlet. Shrink the seal until the green thermo-indicating paint is converted to black. Note: setting of the thermogun. FACC-HEAT-GUN-220V in position 10. Minimum hot air temperature should be 350 C Place the seal over the drop outlet of the base. When the seal butts against the base, mark the sleeve length on the multiduct Shrink down the end of the seal on the multiduct side. Heat till the seal shrinks down onto the multiduct, the green thermo-indicating paint is converted to black and the hot melt is visible at the bottom. Do not move the closure or multiducts (microcables) during 20 mm. 6
7 B Multiple multiducts entries Clean and abrade the appropriate port and cables (over a distance of 200 mm) Position the SCOP at 30 mm from the multiduct jacket and wrap the SCOP around the multiduct (FACC-MC-SCOP-CS-10) Place the seal over the drop outlet of the base. When the seal butts against the base, mark the sleeve length on the SCOP Slide the cable seal over the multiduct(s). Note: make sure the arrow on the seal sleeve (uncoated zone) is pointing towards the base Position the aluminum cable protection foil 15 mm to the inside of the mark on the SCOP. Wrap the aluminum cable protection foil around the SCOP and smoothen. Note: disregard the blue line on the aluminum cable protection foil Push the multiducts into the port till the SCOP butts against the port edge. Secure the microducts into the closure with tape. One can also secure the multiduct on the outside of the closure. Note: securing the microducts(multiducts) prevent the multiduct from moving out of the closure when installing the sleeve. Check the port capacity table (point 1.2) for the allowed configurations Slide the seal over the port. Shrink the seal on the base side with the recommended hot air gun device. Use the reflector to ensure heat distribution around the outlet. Shrink the seal until the green thermo-indicating paint is converted to black. Note: setting of the thermogun. FACC-HEAT-GUN-220V in position 10. Minimum hot air temperature should be 350 C. 7
8 Shrink down the end of the seal on the multiducts side. Heat till the seal shrinks down onto the multiducts, the green thermoindicating paint is converted to black and the hot melt is visible at the bottom. Do not move the closure or multiducts (microcables) during 20 mm All the not used microducts are sealed with the specific ENDCAP connector (5 or 10 mm). On the used 10 mm microducts a blocking connector is installed. The rubber blocking on the 5 mm microduct is installed after the microcable is blown. Note: make sure the blocking connector (10 mm) is installed before the microcable is blown in case of a looped cable. 3.6 Microduct preparation The microcable length needed inside the closure is : - Loop microcable: 4 meter - Drop microcable: 2 meter Tighten the blocking connector by turning the gland clockwise. Hold the body when turning. Note: when the connector is being re-opened (for example:change of microcable), the connector has to be replaced After the cable seal has cooled down, mark and cut the microducts (with the tube cutter) at 70 mm from the bottom of the base. Note: make sure that the tube is not damaged at this spot. When necessary, re-cut the tube Remove the microcable jacket at 15 mm above the blocking connector (10mm microduct) or the microduct (5 mm). Note: make sure the microcable jacket is not being cut with the ripcord (or damaged) within the 15 mm distance from the microduct (5 mm). 8
9 A Oval port (10 mm microducts) B Drop ports (5mm microducts) Secure the strength member connectors Cut the strength members at 100 mm leaving from the microcable jacket. Note: make sure the strength members and fibers are not entangled. Strength Strength members members Rubber blocking 60 mm Rubber blocking 60m Microcable jacket micron fibers fibers Microduct 5 mm Microduct 5mm Measure the distance to the strength member connector, mark and cut the strength members to length Secure the strength members in the strength member connectors. Note: avoid crossings of loose buffer tubes and strength members; one can cut two strength members if necessary Mark the 5 mm microduct(s) at 15 mm from the edge and the strength members of the microcable at 60 mm from this mark (is the length of the rubber blocking) Note: make sure the microcable jacket was 15 mm out of the microduct (microcable can move in the microduct). When a microcable is directly inserted through the port (3.3.8) the rubber blocking is positioned 30 mm onto the microcable (no microduct available) Slide over and position the rubber blocking equal with the mark on the microduct. Make sure the mark on the strength members of the microcable is equal with the other side of the rubber blocking. Move the microcable if necessary. 9
10 Secure a tie wrap around the rubber blocking in the microcable jacket area. Note: make sure that the jacket of the microcable was positioned correctly. 3.7 Termination and routing of the fibers Slide the transportation tube over the loose buffer tube. Slide the SECO onto the transportation tube. A Oval port (10 mm microducts) In case of loops, cut the to be spliced loose buffer tubes in the middle of the loop Divide the fibers into circuits and place each circuit in an outgoing port of the SECO. Note: Do not Secure the SECO into the SECO holder yet Remove the loose buffer tubes leaving 70 mm (X) from the microcable jacket end Slide the small transportation tubes(fopt-sf) over the fiber circuits and insert them into the SECO outlets Insert the biggest transportation tube into the appropriate SECO entrance. Route it towards the microcable, mark and cut the transportation tube at 15 mm (X) from the microcable jacket. 10
11 3.7.7 Secure the SECO into the SECO holder Secure them to the back of the basket. Note: The loop is secured to avoid kinking of the tubes when the closure is turned Route the transportation tubes at the back of the basket as shown. Secure the transportation tubes at the back of the basket. Note: make sure the transportation tubes make smooth(as big as possible) bends Store the uncut loose buffer tubes in the plastic bag Each splice tray accommodates 6 fiber splices maximum, and each side of the tray holds a maximum of 4 transportation tubes. Start with the bottem tray and push the tube in the tray. Use the tray-wedge to support the trays, or remove the upper trays. 11
12 B Drop ports (5 mm microducts) Take the transportation (FOPT-CS) tube and slide it over the fibers When the trays have been removed, insert the first tray in the fifth hole from the bottom Route the transportation tubes around the tray tower to the appropriate tray. Note: Do not route the transportation tube tight around the tray tower. Give them some slack Mark the transportation tube at 15 mm from the end at rubber blocking side Slide the transportation tube into the rubber blocking till the mark (15mm). Make sure the strength members are on the outside of the transportation tube Secure a tie wrap onto the rubber blocking in the transportation tube area Mark the transportation tube at the end of the tray entrance as shown. Carefully cut the transportation tube at the mark Cut the strength members next to the rubber blocking Insert the transportation tube till it butts against the end of the tray entrance. Note: The first tube on a tray should be placed in the inner groove. Make sure the transportation tubes are not routed tight around the tray tower. 12
13 Secure the tray(s) in upwards position by means the tray wedge Insert the transportation tube till it butts against the end of the biggest cavity (middle of the tray entrance). Note: The first tube on a tray should be placed in the inner groove. Make sure the transportation tubes are not routed tight around the tray tower Repeat above steps for each drop. 3.8 Splicing and fiber storage Position the FOSC by the splicing machine in a convenient location and secure the closure Route the transportation tubes into the basket as shown. Note: when all tubes are routed, tubes can be secured with tie wraps Route the transportation tubes around the tray tower to the appropriate tray Note: do not route the transportation tubes tight around the tray tower Slide the heat-shrinkable splice protection over one fiber and fuse fibers according to local recommendations and procedures. After the fusion splice is made, install the heat-shrinkable splice protection (e.g. SMOUV) with appropriate heating source. Allow the splice protection to cool down to ambient temperature After each splice is made, the splice should be stored in the splice holder. Do not deform the splice protector during insertion. The fiber slack should be coiled into the tray. The incoming fibers should be routed at the right side of the little pin (arrow) Mark the transportation tube at the end of the tray entrance as shown. Carefully cut the transportation tube at the mark. 13
14 3.9 Closing the closure Upon completion of splicing, install the clear protective cover on the TOP tray Secure the trays with the Velcro. Open and remove the desiccant bag from the package and place the desiccant in the closure. Note: The tray wedge is secured on the Velcro Transportation tubes are inserted in the tray starting from the inside. Do not route the fibers tight around the island. Make sure all fibers are underneath the containment lips. The cross in the island can be used to make an S in a controlled manner. Example: when the tubes are coming at the same side onto the tray, one side (fibers) have to make the S to be able to splice the fibers together Repeat for all trays and continue with point 3.9) Ensure sealing areas and sealing ring are clean and put sealing ring in place at the base Place the dome carefully over the trays onto the base (arrows should point to each other). Put the clamp around the base/dome interface Close the clamp. 14
15 4 Grounding/shielding Grounding or shielding might in some cases reduce the port capacity. For details, contact the local sales person. 4.4 In case of shielding, connect the wires to the multiducts (point 4.1 to 4.2) and connect the wires to each other with the connector as shown. 4.1 Connect the grounding wire to the multiduct shield. 4.5 Cut the excessive length of the wires. 5 Re-entry 5.1 Remove the clamp. Remove carefully the dome. Remove gently the sealing ring. Keep the sealing ring and seal area of the closure free of dirt (if needed rinse with clear water). 4.2 Put PVC tape underneath and on top. 5.2 Continue with the appropriate points of the instruction. Note: replace the dissicant before closing the closure. 4.3 Put the eyelet (other side of the wire) underneath the washer and nut (grounding). Make a connection with the earth at the bottom side of the closure. 15
16 6 Inter tray jumping 6.1 When it is necessary to splice fibers that are placed on different splice organizer trays an intertray jumper may be used to route one or more fibers to the desired tray. The 1,8 mm tubing must be used. 7 General precautions 7.1 Do not use damaged sleeve nor trim heat-shrinkable sleeve before installation. 7.2 The FOSC-400 closures can be installed at temperatures between -1 C and +45 C. 7.3 Generators used should have enough capacity for the hot air gun utilization. 7.4 The use of Isopropylalcohol is recommended to clean the cable and fibers. 8 Mounting kit 6.2 Push one end of intertray jumper tube into the splice tray,and thru the opening in the bracket. 6.3 Define the length of intertray jumper tube and cut to length. 6.4 Route the fibers in the jumper tube. 8.1 Position the two dome mounting brackets on the dome of FOSC-A/B-POLE-MOUNT. Clamp the brackets into the pole mounting brackets and secure it with the locking pin. 5.5 Carefully bring the intertray jumper tube to the appropriate tray 5.6 The fibers may now be spliced or stored. Tyco Electronics Raychem NV Telecom Outside Plant Diestsesteenweg 692 B-3010 Kessel-Lo, Belgium Tel.: Fax: Velcro is a trademark of Velcro Industries B.V. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, Tyco Electronics makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. Tyco Electronics obligations shall only be as set forth in Tyco Electronics Standard Terms and Conditions of Sale for this product and in no case will Tyco Electronics be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of Tyco Electronics products should make their own evaluation to determine the suitability of each such product for the specific application. TC 716/MC/IP/2 05/03
Gel Drop Seal for FOSC 450 Fiber Optic Splice Enclosure Installation Instructions
Gel Drop Seal for FOSC 450 Fiber Optic Splice Enclosure Installation Instructions TECP-30-215 Issue 1 4/2013 INTRODUCTION The Gel Drop Seal device is for use with FOSC 450 B, B Short, C, and D size closures
More informationINSTALLATION PROCEDURES FOR COATED RAYATEN MOULDED PARTS ONTO D-SUBMINIATURE CONNECTORS
Rayaten Moulded Parts Installation Procedures Code of Practice ELE-3COP-508 27 th Mar 2018 Class I INSTALLATION PROCEDURES FOR COATED RAYATEN MOULDED PARTS ONTO D-SUBMINIATURE CONNECTORS ELE-3COP-508 TE
More informationTDUX Inflatable Duct Sealing System 1.0 General Product Information
TDUX I N S T A L L A T I O N I N S T R U C T I O N Inflatable Duct Sealing System 1.0 General Product Information The TDUX inflatable duct sealing system is a wraparound, inflatable, mastic-lined bladder
More informationALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES
Rayaten Moulded Parts Installation Procedures Code of Practice ELE-3COP-524 23 rd Mar 2018 Class I ALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES ELE-3COP-524
More informationPREPARATION & APPLICATION OF S1125 ADHESIVES
S1125 ADHESIVE Code of Practice ELE-3COP-604 8 th Sep 2017 Class I PREPARATION & APPLICATION OF S1125 ADHESIVES ELE-3COP-604 TE Raychem S1125 Adhesives ELECTRONIC APPROVAL, NO SIGNATURES WILL APPEAR. IF
More informationINSTRUCTION MANUAL. January 23, 2003, Revision 0
INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,
More informationCamRT Sun Top Bimini Installation Instructions
CamRT Sun Top Bimini Installation Instructions C910-07 & C910-08 Rev. 16-Jun-15 Information: info@roswellglobal.com Warranty: warranty@roswellglobal.com Questions? Please call us at (31) 638-1331 Setup:
More informationTECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS
TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS CONTENTS: 1.0 General Information 2.0 Preparation and Splicing of PinPoint Wire 3.0 PinPoint Direct Bury Splice Kit Specifications
More informationOFS LT1B Instruction Sheet Splice Organizer Comcode: D02AK0025 Installation
OFS LT1B 636-299-103-52 Instruction Sheet Splice Organizer Comcode: D02AK0025 Installation Preface This Instruction covers the installation of the LT1B Splice Organizer. Contents: Step 1 Identify Parts
More information602 STRINGING MACHINE OWNER'S MANUAL
PROGRESSION 602 STRINGING MACHINE OWNER'S MANUAL AL Issue 1- April 2000 Copyright 2000 GAMMA Sports - All Rights Reserved PROGRESSION 602 STRINGING MACHINE TABLE OF CONTENTS PAGE 1... WARRANTY PAGE 2...
More informationOWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved
OWNER'S MANUAL AL Issue 2 - August 19, 1999 Copyright 1999 ATS - All Rights Reserved OWNER'S MANUAL TABLE OF CONTENTS PAGE 1... WARRANTY PAGE 2... ASSEMBLY INSTRUCTIONS PAGE 4... MOUNTING THE RACQUET PAGE
More information830 SureFlo Soap Systems Installation Instructions. Foam Soap Cabinet... Pages 2-9 Liquid Soap Cabinet... Pages 10-19
830 SureFlo Soap Systems Installation Instructions Foam Soap Cabinet... Pages 2-9 Liquid Soap Cabinet... Pages 10-19 INSTALLATION INSTRUCTIONS SureFlo SOAP DISPENSING SYSTEM FOAM VERSION ONLY B-830 Foam
More information3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor
Membrane Contactors 3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety Information 3 II. Required Materials 4
More informationCOOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN
Deadbreak Apparatus Connectors MN650043EN Effective February 2017 Supersedes October 2004 (S550-12-1) 200 A 15/25 kv class deadbreak straight connector installation instructions COOPER POWER SERIES DISCLAIMER
More informationCongratulations on your purchase of a JC Series Performer trike! The Performer JC Series is designed for everything from touring to commuting and
Congratulations on your purchase of a JC Series Performer trike! The Performer JC Series is designed for everything from touring to commuting and shopping in the city. The JC Series frames are made of
More informationFibre Optic Closure 2179-CS
Fibre Optic Closure 2179-CS The Fibre Optic Closure 2179-CS is designed and developed based on the proven 3M sealing technology. It is made of plastic molded parts and mastic sealing materials. Closing
More information3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps
Membrane Contactors 3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety
More information600 / 600FC OWNER'S MANUAL
PROGRESSION 600 / 600FC OWNER'S MANUAL Issue 2 / Version E - Dec. 10, 1997 Copyright 1997 GAMMA Sports - All Rights Reserved PROGRESSION 600 / 600FC OWNER'S MANUAL TABLE OF CONTENTS PAGE 1... WARRANTY
More informationShimano Di2 Installation on S5
Installing Shimano Dura Ace Di2 Shifting Systems Note these instructions and pictures are for assembling the Shimano Dura Ace Di2 system (Internal Spec) on the Cervélo S5 frame. The Shimano Ultegra Di2
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS SureFlo Soap Dispensing System Bobrick SureFlo Soap Dispensing System Soap Cabinets, Soap Dispensers and connections are available from all Bobrick Distributors. Bobrick SureFlo
More informationUnisense In Situ UniAmp Connector System
Unisense In Situ UniAmp Connector System Overview The Unisense In Situ UniAmp Connector system is designed for easy replacement of sensors. Unisense In Situ UniAmp Connector system is a dedicated system
More informationmax 80 cm / 2 6 Trittfrequenzmesser Capteur de Cadence Trapfrequentie Sensor Sensor de Cadencia Sensore di Cadenza Sensor de Cadência Kadencesensor
1 max 80 cm / 2 6 2a 2b 3 4 5 max 4 mm / 0 16 ENGLISH The Polar Cadence Sensor is designed to measure cadence when cycling. No other use is intended or implied. It is compatible with Polar Cycling Computers
More informationIMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION
IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION This Fitting Guide is designed to assist in the Installation of your Reverse Osmosis System. Some of the parts that are supplied with each system may
More informationTripod Setup Guide (M-TPx)
Items needed: 1/2 inch wrench, mast level (M-MLA), medium size wire cutters, crescent wrench, all-purpose grease, tape measure, tie wraps, redi-mix cement (optional), shovel (optional), sledge hammer (for
More informationSpring steel fasteners KWHS-14R. KwikWire. Hanging system
Spring steel fasteners KWHS-14R KwikWire Hanging system KwikWire Hanging System Takes the strain out of hanging with chain The KwikWire Hanging System is a flexible replacement for jack chain and all thread
More informationB-LINE SERIES. Spring steel fasteners KWHS-15. KwikWire. Hanging system
Spring steel fasteners KWHS-5 B-LINE SERIES KwikWire Hanging system KwikWire hanging system. Takes the strain out of hanging with chain Application Photos Applications for the KwikWire Hanging System include:
More informationOWNER'S MANUAL. Copyright 2003 GAMMA - All Rights Reserved
OWNER'S MANUAL AL Issue 1 - December 2003 Copyright 2003 GAMMA - All Rights Reserved OWNER'S MANUAL TABLE OF CONTENTS PAGE 1... WARRANTY PAGE 2... ASSEMBLY INSTRUCTIONS PAGE 4... MOUNTING THE RACQUET PAGE
More informationSECTION 2 RING MOUNT
SECTION 2 RING MOUNT Rotax aircraft engines are manufactured and supported by Rotax GmbH of Austria. Read and understand the Rotax manuals completely before starting with the engine installation, as they
More informationVelocity - AMD USER GUIDE CPU WATER BLOCK. 2nd Revision, October 19th 2018
Velocity - AMD CPU WATER BLOCK 2nd Revision, October 19th 2018 USER GUIDE This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper
More informationVERSA BIKE RACK INSTRUCTIONS
VERSA BIKE RACK INSTRUCTIONS Models #8, 8 Important This rack is designed for use with a or. receiver hitch. The rack is designed to hold a maximum of two bicycles. Do not use it for anything other than
More informationCOOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013
Switches MN008005EN Effective April 2016 Supersedes S328-120-1 June 2013 D-73P3 bypass switches installation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information,
More information2019 MADONE ASSEMBLY MANUAL
2019 MADONE ASSEMBLY MANUAL 2019 MADONE Rim brakes and Di2 drivetrain Rim brakes and mechanical drivetrain Disc brakes and Di2 drivetrain Disc brakes and mechanical drivetrain TABLE OF CONTENTS Common
More informationWIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM
CLIPPER WIND KTS ILLUM SCALE DEC INC CLIPPER WIND SYSTEM TABLE OF CONTENTS INTRODUCTION PRE-TEST OF INSTRUMENT INSTALLING THE MASTHEAD SENSOR UNIT INSTALLING THE DISPLAY NORMAL OPERATION CHANGING THE
More informationVelocity USER GUIDE CPU WATER BLOCK. 1st Revision, September 6th 2018
Velocity CPU WATER BLOCK 1st Revision, September 6th 2018 USER GUIDE This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper
More informationUnderwater Fiber-Optic Plane Irradiance Collector
Underwater Fiber-Optic Plane Irradiance Collector User s Manual Revision F, October 2018 Hōbi Instrument Services www.hobiservices.com Revisions F October 2018, improved illustrations, table of immersion
More informationINSTALLATION INSTRUCTIONS
EDGEMERE CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More informationCOOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN
Connectors MN650027EN Effective November 2016 Supersedes January 2014 (IS550-11-1) DS250 deadbreak straight connector installation instructions interface A COOPER POWER SERIES DISCLAIMER OF WARRANTIES
More informationInstruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves
Instruction Manual PE-25/32/37 Tapping Machines & POLYTAPP Valves Nov 2016, Revision 2 Document Number 3000111 2 M.T. Deason Company, Inc. PO Box 101807 Birmingham, AL 35210 Phone: 205 956 2266 Fax: 205
More information3M Liqui-Cel EXF-10x28 Series Membrane Contactor
Membrane Contactors 3M Liqui-Cel EXF-10x28 Series Membrane Contactor Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety and Warning 3 II. Assembly Parts 4 III. Part Orientation
More informationOWNER'S MANUAL FREE FALL ROPE AND CHAIN ANCHOR WINCH. 12 Volt Powered Winch Power-In / Freewheel-out operation. 36', 41' and 46' Class Anchor Winch
OWNER'S MANUAL 36', 41' and 46' Class Anchor Winch FREE FALL ROPE AND CHAIN ANCHOR WINCH PW46101 12 Volt Powered Winch Power-In / Freewheel-out operation These instructions apply to all models listed.
More information3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide
3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide Description: AIR SUPPLY LINE KIT Product ID/Stock No.: 62-9895-0005-3 For use with: 3M Scotch-Weld Polyurethane
More informationLectric Cycles Mid-Drive Electric Motor Installation
Lectric Cycles Mid-Drive Electric Motor Installation This write-up describes the installation of a Lectric Cycles electric motor. The model is the e-rad Mid-Drive 750 Watt conversion kit, installed on
More informationChapter 9 Accessories for the Kirby Morgan BandMasks
Chapter 9 Accessories for the Kirby Morgan BandMasks 9.1 Introduction This section provides the manufacturer s advice on how to install KMDSI accessories including the hot water shroud, low pressure inflator
More informationSection 9 COYOTE Closures & Splice Cases for OPGW & ADSS
COYOTE Closures & splice cases for OPGW & ADSS: Section 9 Section 9 COYOTE Closures & Splice Cases for OPGW & ADSS Table of Contents COYOTE Closures and Splice Cases for OPGW and ADSS...9-2 COYOTE Closures
More informationThe Outer Seal is highly abrasion resistant and provides mechanical stiffness to the splice in order to better match the cable stiffness.
The Sealing Compound encapsulates the electrical splices, provides a strain relief for the conductors, acts as a water block, eliminates air voids which tend to act as pumps to draw in water during pressure
More informationUSER S GUIDE & SAFETY MANUAL USER S GUIDE & SAFETY MANUAL Duct Rodder
USER S GUIDE & SAFETY MANUAL USER S GUIDE & SAFETY MANUAL Duct Rodder Table of Contents 1. 2. 3. 4. 5. Safety Notice... 3 Operator s Instructions... 4 Duct Rod Sizes... 5 Duct Rodder Assembly... 6 Duct
More informationKAYAK ERGOMETER. Operating Instructions (Rev 3.0)
KAYAK ERGOMETER Operating Instructions (Rev 3.0) Weba Sport und Med.- Artikel GmbH Liesneckgasse 6/1 1210 Vienna Austria Tel.: ++43 1 2723550 Fax: ++43 1 27235504 office@webasport.at www.weba-sport.com
More informationSUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide
SUMMITTM 400 & 600 Natural Gas Barbecues Step-By-Step Guide W E B E R W E B E R W E B E R W E B E R Summit 400 NG Summit 600 NG CANADIAN GAS ASSOCIATION R A P P R O V E D WARNING: Follow all leak check
More informationULTRA-LIGHT DUTY ONBOARD AIR SYSTEM
ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM PART NO. 10000 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using
More information/50/100 Pair. Protected Entrance Terminals
Protected 3M Protected provide voltage surge and high current protection and are available in sizes ranging from 25-, 50-, and 100-pair wall mount units. The terminals have a wide selection of station
More informationUses, Certifications, and Standards FASTENERS,KWIK WIRE,Lighting, Ductwork, Cable Tray
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 BKP10094 SPRG Wire Rope/CLMP Kit Cooper B-Line/Cable Tray Manufacturer Description Weight per unit Product Category Features
More informationTrike-Bike Assembly Manual
Be sure to check our website for more instruction details, videos and photographs as well as a complete listing of each Nut and Bolt for the Trike Bike. www.trike-bike.com.au Go to the page marked ASSEMBLY
More informationE-trike Li Assembly Guide
PREPARATION 1. Read this assembly manual BEFORE commencing assembly. 2. Carefully remove all the components and packaged hardware from the shipping boxes. 3. Unpack the contents of the large double box
More informationRudder Kit Assembly Instructions for Quest 13
Rudder Kit Assembly Instructions for Quest 13 Revised 4/2/2015 78501 Rudder System The Hobie Quest is designed for the addition of an optional rudder system. Rudder systems in boats like this allow you
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More informationX-6FC STRINGING MACHINE OWNER'S MANUAL. Issue 1 - May Copyright 2004 GAMMA Sports - All Rights Reserved
X-6FC STRINGING MACHINE OWNER'S MANUAL Issue 1 - May 2004 Copyright 2004 GAMMA Sports - All Rights Reserved OWNER'S MANUAL GAMMA X-6FC TABLE OF CONTENTS PAGE 1... WARRANTY PAGE 2... FEATURES PAGE 3...
More informationFalcon 3 145, 170, 195 and Tandem Owner / Service Manual
Falcon 3 145, 170, 195 and Tandem Owner / Service Manual January 2007 - Second Edition Removing The Sail From The Airframe And Short Packing The Glider Many maintenance and repair procedures will require
More informationVelocity USER GUIDE CPU WATER BLOCK. 2nd Revision, October 18th 2018
Velocity CPU WATER BLOCK 2nd Revision, October 18th 2018 USER GUIDE This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper
More informationCOOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN
Screened Separable Connectors MN650025EN Effective November 2016 Supersedes September 2013 (IS550-10-1) DE250 deadbreak elbow connector installation instructions interface A COOPER POWER SERIES DISCLAIMER
More information2019 MADONE ASSEMBLY MANUAL
2019 MADONE ASSEMBLY MANUAL 2019 MADONE Rim brakes and Di2 drivetrain Disc brakes and Di2 drivetrain Rim brakes and mechanical drivetrain Disc brakes and mechanical drivetrain TABLE OF CONTENTS Common
More informationSASK-A-POLE OWNERS AND USERS MANUAL
SASK-A-POLE OWNERS AND USERS MANUAL GENERAL INFORMATION The Saskatchewan Abilities Council s Sask-a-Pole accessibility and transfer aid is designed to help provide safe and easy access to chairs, beds,
More informationBKC100 SPRG Clamp For Wire Rope. Dimensions and Weight. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 BKC100 SPRG Clamp For Wire Rope Cooper B-Line/Cable Tray Manufacturer Description Weight per unit Product Category Dimensions
More informationBoat Boat Loader Fitting Instructions
Aerodynamic & Heavy Duty Roof Rack Systems Australian Made - Australian Owned www.rhinorack.com Boat Boat Loader Fitting Instructions CONTROLLED Balance point 3 Front eye nuts position 3 Transom eye nut
More informationOPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M)
OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 3K Puller (M3K-M) 04/17 (M3K-M) READ AND UNDERSTAND ALL OF THE INSTRUCTIONS AND SAFETY INFORMATION IN THIS MANUAL BEFORE OPERATING OR SERVICING THIS TOOL TABLE
More informationSANTANA STOWAWAY TANDEM WITH AIRLINER SAFECASE AND FTS FOAM TRAY SYSTEM ASSEMBLY AND DISASSEMBLY
SANTANA STOWAWAY TANDEM WITH AIRLINER SAFECASE AND FTS FOAM TRAY SYSTEM ASSEMBLY AND DISASSEMBLY Congratulations! You are now the proud owner of the world s most travel-ready, performance tandem. The following
More informationInstallation and Operating Instructions for Automotive Winch Synthetic Rope
Installation and Operating Instructions for Automotive Winch Synthetic Rope 2 1 Synthetic Rope Kit Parts List Part No. 251262 1. Rope Assembly (3/8 x 100 ) 2. Hook Strap WARNING: A minimum of EIGHT wraps
More informationRear Drive System SERVICE INSTRUCTION. Specifications SI-R670B
- SERVICE INSTRUCTION SI-R670B t Rear Drive System Before use, read these instructions carefully, and follow them for correct use. In order to realize the best performance, we recommend that the following
More informationSPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
More informationInstallation Instructions
Installation Instructions COLONY SOFT 7.0 Centerset Lavatory Faucet 7.0 with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a features found
More informationPre-Paint>Fuselage>Empennage>Fit vertical tail fin. Objectives of this task: Materials and equipment required: Fit the spar extender
Pre-Paint>Fuselage>Empennage>Fit vertical tail fin Objectives of this task: To fit the vertical tail fin to the fuselage, including fitting the static probe, static tube, optional strobe light wiring and
More informationBMW Motorrad. Installation Instructions. BMW Motorrad Communications System for Schuberth C3
BMW Motorrad Installation Instructions BMW Motorrad Communications System for Schuberth C3 Order No. 01 29 2 219 831 BMW Motorrad 05/2011 Be sure to read these instructions carefully and completely before
More informationTABLE OF CONTENTS INTRODUCTION
R3 DISC MANUAL TABLE OF CONTENTS Introduction... 1 Frame Features... 2 Fork Preparation... 3 Small Parts... 5 Frame Preparation... 6 Brake Housing Installation... 7 Mechanical Cable Routing... 9 Electric
More informationFinal Assembly Instructions Bikes with 16 Wheel Size
Final Assembly Instructions Bikes with 16 Wheel Size Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping, our expert
More informationStandard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332
Setup Guide Standard Standard Light. Part No: 000 Brown. Part No: 00 Black. Part No: 00 Part No: 065-964 Issue, June 0 0 Limbs & Things For more skills training products visit limbsandthings.com Limbs
More informationInstruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.
Instruction Manual Model TC1-S TopSide Clamp top side clamp (406)755-4258 (406)257-2711 www.timberlinetool.com 90 Conestoga Ct. Kalispell, MT 59901 USA For your personal safety READ and UNDERSTAND instructions
More informationPR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)
PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included) March 2006 Form FVC 054 Rev. 6 KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. The Passive - R4 device
More informationRESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx
EN 1496:2006 / B Reference number: RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx DESIGNATED USE The rescue lifting device RUP 503-[...] series is a component of rescue system. Using this device the
More informationOPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)
OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M) READ AND UNDERSTAND ALL OF THE INSTRUCTIONS AND SAFETY INFORMATION IN THIS MANUAL BEFORE OPERATING OR 04/17 (M6K-M) SERVICING THIS TOOL TABLE
More informationFor ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35
INSTALLATION AND OPERATING INSTRUCTIONS ANCHOR WINCHES For ELECTRIC ANCHOR WINCH Models: T10109-35 Pontoon 35 T10102-35sw Salt Water Series Coastal 35 If you have any questions or difficulty installing
More informationLUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010
LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants
More informationPage 1 of 1 04/19/13 SBR
Office of Roadway Engineering - Plan Insert Sheets Number Title Date Number Title Date Number Title Date 201015 Extension of Anchor Bolts 07/20/12 207000 Bikeway Pavement Marking Details 01/18/13 202010
More information7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike
7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike Owner s Manual Made in Taiwan INDEX IMPORTANT SAFETY INFORMATION... 1 EXPLODED DRAWING... 2 PARTS LIST... 3 ASSEMBLY INSTRUCTION... 4-9 USER
More informationInstruction Manual. PE Pipe Squeeze-off Tool Model TR650
PE Pipe Squeeze-off Tool Model TR650 Instruction Manual For your personal safety READ and UNDERSTAND instructions before using tools. SAVE these instructions for future reference. SPECIFICATIONS Table
More informationVertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment
3M Occupational Health and Environmental Safety Fall Protection Equipment Ladder Climb Vertical Lifeline User Instructions User Instructions for the 3M TM Ladder Climb Vertical Lifeline System. Important:
More informationOMS P/N: Rev.: B. Description OMS: ASSY BACKUP POD 6.0. DCR# 3137 Date: Operation: Special Instructions: TQC. Torque.
DCR# Date: -0- ASSY BACKUP POD.0 BPEVE OMS P/N: 00-09 Rev.: B Page: of NA P-Touch Labels Apply Label & Serial Number/Part Number Label onto the front of the chassis as shown. OMS Template: 00-00 Rev. A
More information200 STRINGING MACHINE
200 STRINGING MACHINE OWNER S MANUAL Issue 1 - July 2010 Provided by www.gssalliance.com 200 OWNER S MANUAL TABLE OF CONTENTS WARRANTY...PAGE 2 FEATURES...PAGE 3 ASSEMBLY INSTRUCTIONS...PAGE 4 MOUNTING
More informationFinal Assembly Instructions Bikes with Quill Stems
Final Assembly Instructions Bikes with Quill Stems Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping, our expert
More information*******WARNING******
*******WARNING****** UPON INSTALLATION OF ANY FOSTECH OUTDOORS, LLC BUMP FIRE STOCK YOU ARE AGREEING WITH THIS WARNING AND THE LIABILITY STATEMENT BELOW. IF YOU DO NOT AGREE, PLEASE FEEL FREE TO PRESENT
More informationUniversal Elevator Mount Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.
REQUIRED TOOLS AND MATERIALS: 2 Capable Adults Carpenter s Level 15 Tape Measure Pencil Universal Elevator Mount Owners Manual Customer Service Center N53 W2400 South Corporate Circle Sussex, WI 530 U.S.A.
More informationDT400/436 Tee Connector Installation Instructions
Connectors Lorem ipsum and dolor Splices sit Amat Effective September 2014 Supersedes IS550-30-1 March 2011 MN650001EN DT400/436 Tee Connector Installation Instructions DISCLAIMER OF WARRANTIES AND LIMITATION
More informationIndex 1. Trampoline 2. Main Foils 3. Spinnaker Pole 4. Mast Setup 5. Mast Rigging 6. Rig Tension 7. Trapeze Lines 8. Rudders 9. Boom 10. Main Sheet an
By User Manual Index 1. Trampoline 2. Main Foils 3. Spinnaker Pole 4. Mast Setup 5. Mast Rigging 6. Rig Tension 7. Trapeze Lines 8. Rudders 9. Boom 10. Main Sheet and Traveler 11. Main Sail 12. Downhaul
More informationSplicing Instructions. Standard Double Braid Eye Splice Type 1 Double Braid Ropes
Splicing Instructions Standard Double Braid Eye Splice Type 1 Double Braid Ropes Introduction Double Braid Eye Splice This document describes the steps required to perform a Double Braid Eye Splice in
More informationRecommendations for Marking Power Facilities
Recommendations for Marking Power Facilities with the Use of 3M EMS Electronic Markers 1.0 Overview Revised June 21, 2005 Page 1of 12 The 3М TM electronic marker system is intended to make the job of precisely
More information3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors
Membrane Contactors 3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors Assembly and Disassembly Instructions 3M.com/Liqui-Cel TABLE OF CONTENTS I. Safety and Warning 3 II. Assembly Parts 4 III.
More informationPaintball Marker. User s Manual. Direct Feed. SC: Stock Class. VSC: Vertical Air Stock Class. 530 South Springbrook Road Newberg, OR 97132
Paintball Marker User s Manual Direct Feed SC: Stock Class 530 South Springbrook Road Newberg, OR 97132 VSC: Vertical Air Stock Class www.phantomonline.com Component Concepts, Inc., 530 South Springbrook
More informationEZee Glider Manual. Tools needed for Assembly: Wrench (included) Philips Screwdriver (not included) Assembly Instructions
EZee Glider Manual Congratulations on your purchase of the EZee Glider! Your glider is designed for years of nearly carefree use by your child. These instructions include how to set up your glider and
More informationX-6 STRINGING MACHINE OWNER'S MANUAL. Issue 1 - May Copyright 2004 GAMMA Sports - All Rights Reserved
X-6 STRINGING MACHINE OWNER'S MANUAL Issue 1 - May 2004 Copyright 2004 GAMMA Sports - All Rights Reserved OWNER'S MANUAL GAMMA X-6 TABLE OF CONTENTS PAGE 1... WARRANTY PAGE 2... FEATURES PAGE 3...ASSEMBLY
More informationVERSION 1.2 R-TRACK USER GUIDE. ZiPPERTUBiNG CO. THE. (480)
VERSION 1.2 USER GUIDE THE ZiPPERTUBiNG CO. www.zippertubing.com (480) 285-3990 R Table of Contents pg.2 TABLE OF CONTENTS Introduction... 3 Track Closure vs Bend Location... 4 Installation... 5 Sealing
More informationOPERATIONS MANUAL IMPORTANT SAFETY INFORMATION
OPERATIONS MANUAL IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this tool. Retain these instructions for further
More informationInstallation Instructions - Electric Steel Drive Systems for Arm Sets to ,
Installation Instructions - Electric Steel Drive Systems for Arm Sets to 22 208-025, 209-025 NB /0/ 607-0029 404 N. Marshall Ave. El Cajon CA. 92020 For technical support call us at (800) 368-3075 Step.
More information