LM6 LEATHER MOISTURE METER

Size: px
Start display at page:

Download "LM6 LEATHER MOISTURE METER"

Transcription

1 CHECK LINE BY ELECTROMATIC LM6 LEATHER MOISTURE METER Operating Manual

2 TABLE OF CONTENTS 1.0 Introduction Operation and handling 1.2 Measuring procedure 2.0 Calibration curves Selection of calibration curves 3.0 Determination of the reference water content Short description of norm DIN Design of the device Menu 4.2 Key functions in the menu 5.0 Common reasons for incorrect measurements Looking after the instrument Exemption from liability 7.0 Changing the batteries Calibration Checking the calibration 8.2 Calibration procedure 9.0 Technical data Warranty

3 1.0 INTRODUCTION 1.1 Operation and handling Switching on: Press the button for 3 seconds. Changing the calibration curve: or key. Switching on the display lighting: Press the button briefly; the lighting switches off automatically after approx. 20 seconds. Pressing any key activates the lighting again and prolongs the switch-off time to 4 minutes. Switching off: Press the key for 5 seconds; the device will switch off after releasing the key. After approx. 4 minutes the device will switch off automatically. 1.2 Measuring procedure 1. Switch on the humimeter LM6 by pressing the key for 3 seconds. 2. Select the appropriate calibration curve using the arrow keys. Hold the device in one hand and press it onto the leather well-setted (4 kg compacting pressure). The leather pile has to be at least 10mm high! 3. The display shows the water content immediately (large numbers). 2

4 2.0 CALIBRATION CURVES NAME CALIBRATION CURVE DENSITY Leather LD Leather of low density 0.55 g/cm³ Leather CR Leather chrome tanned 0.60 g/cm³ Leather MD Leather of medium density 0.65 G/CM³ Leather FOC Leather free of chrome, fire protection leather 0.70 g/cm³ Leather HD Leather of high density 0.75 g/cm³ Leather VHD Leather of very high density 0.80 g/cm³ Reference Only for checking the instrument 2.1 Selection of calibration curves Due to different manufacturing methods and different densities of the leather there is no standardised allocation of calibration curves. In the above list of calibration curves you can find information regarding manufacturing methods and density that enables a preselection of the calibration curve. To ensure the best accuracy of your measurement, we recommend to carry out a comparison measurement by kiln-drying (norm DIN 53304) once: 1. Take a leather pile of 10-15mm of the format A6 with average moisture content. 2. Measure the water content of this leather pile using all available calibration curves and write down the measuring results of the different calibration curves. 3. Take the 2 top leather pieces of the pile and carry out a reference measurement according to DIN Compare the determined reference water content with the measuring results of the different calibration curves. Use the calibration curve with the measuring result nearest to the reference water content. 3

5 3.0 DETERMINATION OF THE REFERENCE WATER CONTENT The humimeter LM6 determines the water content, which means that it calculates the moisture referred to the total mass (DIN53304): Mn Mt % WG = 100 Mn Mn: Mass with average moisture content Mt: Mass of the dried sample %WG: Calculated water content 3.1 Short description of norm DIN53304 Take a leather piece according to DIN T2 or DIN T2. For the determination of the water content, weigh the leather piece with an accuracy of 0,001 g (mass Mn). Put the piece of leather in a glass bowl that was dried at (102 ± 2) C and was weighed after cooling to room temperature. Dry the opened glass bowl in a drying chamber at (102 ±2) C for 5 hours. After closing the glass bowl cool it in an exsiccator. Now determine the mass (Mt). After that, go on with the above described drying procedure in the drying chamber for one further hour, cool and weigh again. If the weight after the second drying period decreases less than 0.1 % of the initial weight, the assay is finished. If the decrease of weight is higher than 0.1 %, the drying has to be continued. The total period of drying must not exceed 8 hours. 4

6 4.0 DEVICE DESIGN Calibration Curve Measuring Value Temperature Measuring Value Moisture Rolling Menu Resp, Hold Key ON/OFF Button Changing Calibration Curve Rubber Protective Housing Batteries Slot (flipside) 5

7 4.1 Menu There are 3 menu levels The symbols show the key functions in the different menus. Main menu Edit logs Manual logs 1. Type selection: Clear logs 2. Saving: Print logs 3. Main Menu Last Logs Rolling menu: Use this key to enter the different menu levels and main menu. Power: Press this key for 3 seconds to switch the instrument off or on. Press this key briefly to activate the display lighting. Up: This key moves you to the next type/calibration curve. Down: This key moves you to the previous type/calibration curve. All logs Clear logs Send logs Manual logs Clear logs Options Date / Time Logtime Language Disk: Use this key to save measurement Unlock values. C / F If the number in front of the disk symbol Calibrate increases, the measuring value has been saved o Userlevel BL On Time Alternatively: Hold: The currently shown measurement value is held. It is released when another key is pressed. View logs: If no logs are active, you can use this symbol to view the saved measuring series Alternatively: Edit logs: If logs are active, Status you can press this symbol and then enter e.g. batch number and supplier s data for the series. In the saving level, press 4.2 Key functions in the menu (rolling menu) to enter the main menu. : Confirm activates menu item : Up long press => jumps to the start of the menu : Down long press => jumps to the end of the menu : Exit exits the menu item or menu Auto Off time Materialcalib. Password Reset SN Logo Tm Admin 6

8 5.0 COMMON REASONS FOR INCORRECT MEASUREMENTS Wrong calibration curve Double check the correct selection of the calibration curve before measuring. The calibration curve reference must NOT be used. Inadequate thickness of the leather pile A single leather hide must NOT be measured. Pile the leather to ensure a thickness of at least 10 mm. Metal below the material During the measurement there must NOT be any metal for at least 100 mm under the measured material. Product temperature out of application range The application range is between 0 C and +40 C Discrepancy in temperature between device and material Please ensure that the device and the material under test are being stored at nearly the same temperature before measuring. A high temperature difference has a negative effect on the stability of the measurement results. 6.0 LOOKING AFTER THE INSTRUMENT Do not drop the instrument or expose it to excessive temperatures. Only clean it with a lint-free, dry cloth. The instrument is not waterproof. How often you need to check the instrument depends on the use and the required level of accuracy in your field of operation. For a fee, Messtechnik Schaller GmbH can also carry out a calibration at their factory. In this case you will also receive a calibration certificate. 6.1 Exemption from liability For miss-readings and wrong measurements and of this resulting damages we refuse any liability. As this rapid measurement procedure is influenced by product-specific and application-specific conditions, we recommend to carry out a plausibility check on the measurement results. Each instrument has a serial number and a warranty seal. If this is broken we cannot provide warranty. If the instrument is defective, contact Messtechnik Schaller GmbH or your supplier. 7

9 7.0 CHANGING THE BATTERIES Your new device is provided with batteries. Please find enclosed the manual for changing of batteries: 1. At first remove the rubber protective housing. For that, hold the rubber housing at the upper side and pull it over. If your humimeter is provided with an optional USB port, you have to remove the protection cap before. Press with your finger onto the arrow of the battery cap und pull it back. 2. Remove the empty batteries. 3. Put four new batteries in the device. Make sure that the position of the battery poles is correct. 4. Press down the batteries and close the cap. 8

10 8.0 CALIBRATION 8.1 Checking the calibration We recommend to check the calibration of the humimeter LM6 every 4 weeks, using the proof plate delivered with the device. For this check the device has to show a temperature between 18.0 and 24.0 C. 1. Switch on the instrument and select the calibration curve reference using the arrow keys. 2. Hold the humimeter LM6 in one hand and press it onto the grey proof plate (compacting pressure of 4.0kg). The shown measuring value should range between 14.5 and If the shown value is out of this range, you have to carry out a calibration (see instructions below) 8.2 Calibration procedure By a zero point adjustment you can correct a too high deviation of the calibration check. For that please proceed as follows: 1. Press the left key twice to reach the menu level. Navigate to the menu item Options using the arrow keys. Confirm by pressing the button. 2. Select the menu item Calibrate using the arrow keys a znd confirm by pressing the button. 3. This menu item has to be unlocked. For that you have to enter the 4-digit serial number of your humimeter LM6. You can find the serial number on the top right edge of your display a short time after switching on the instrument, or on the sticker in the battery slot. 9

11 4. Press the third button as long as the black bar stands on the first digit of the serial number. After a waiting time of a few seconds the device accepts the entered digit. Now the other 3 digits have to be entered. When the 4-digit number has been entered correctly (see picture), press the button to confirm. 5. The request Reinitialize? will appear at the display. Hold the humimeter LM6 in one hand and make sure that nothing stands behind the measuring field (black plate). 6. Now press the second button ( ) with one finger. The calibration procedure will take a few seconds. During that time, the instrument has to be held up in the air and the measuring field must NOT be touched. 7. The device is ready when the shown picture on the right disappears automatically. 10

12 9.0 TECHNICAL DATA Measuring depth Minimum material thickness Resolution Measuring range Temperature measuring range in (5mm) (10mm) 0.1% water content ; 0.1 C ; 0.3 F 3% to 65% water content 14 C to 122 F ( 10 C to +50 C) Operation temperature range 32 F to 104 F (0 C to +40 C ) Storage temperature Temperature compensation Memory for measured value Menu language Power supply Switch off time Power consumption Display Dimensions Weight (incl. batteries) 4 F to 140 F ( 20 C to 60 C) Automatic Protection class IP 40 Scope of supply Options Approx values German, English, French, Italian, Spanish, Russian 4 x 1.5 Volt AA Alkaline batteries (for approx. 900 measurements) After approx. 4 minutes 60 ma (with display lighting) 28 x 64 matrix display, with LED- backlighting 5.79 in x 2.95 x 1.18 in (147mm x 75mm x 30mm) 9.35 oz. (265g) LM6, 4 x 1.5 Volt AA Alkaline batteries, wooden case, proof plate, rubber protective housing, user manual PC interface including software and cable, mobile printer (only with option 1) 11

13 WARRANTY ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications thereof. Product failure or malfunction arising out of any defect in workmanship or material in the product existing at the time of delivery thereof which manifests itself within one year from the sale of such product, shall be remedied by repair or replacement of such product, at ELECTROMATIC s option, except where unauthorized repair, disassembly, tampering, abuse or misapplication has taken place, as determined by ELECTROMATIC. All returns for warranty or non-warranty repairs and/or replacement must be authorized by ELECTROMATIC, in advance, with all repacking and shipping expenses to the address below to be borne by the purchaser. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER S OR SUPPLIER S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE. Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. The duration of any implied warranty, including, without limitation, fitness for any particular purpose and merchantability with respect to this product, is limited to the duration of the foregoing warranty. Some states do not allow limitations on how long an implied warranty lasts but, not withstanding, this warranty, in the absence of such limitations, shall extend for one year from the date of invoice. ELECTROMATIC Equipment Co., Inc. 600 Oakland Ave. Cedarhurst, NY USA Tel: / Tel: / Fax: Every precaution has been taken in the preparation of this manual. Electromatic Equipment Co., Inc., assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of information contained herein. Any brand or product names mentioned herein are used for identification purposes only, and are trademarks or registered trademarks of their respective holders. 12

14 CHECK LINE INSTRUMENTS ELECTROMATIC E Q U I P M E N T C O., I N C. 600 Oakland Ave., Cedarhurst, NY USA TEL: FAX:

WARNING NOTES TABLE OF CONTENTS

WARNING NOTES TABLE OF CONTENTS NOTES TABLE OF CONTENTS 1.0 Introduction.................................................. 2 1.1 Unpacking 1.2 Complete Kit 2.0 Operating Procedures.......................................... 3 2.1 Memory

More information

NOTES TABLE OF CONTENTS

NOTES TABLE OF CONTENTS NOTES TABLE OF CONTENTS 1.0 Introduction.................................................. 2 1.1 Unpacking 1.2 Complete Kit 2.0 Operating Procedures.......................................... 3 2.1 Memory

More information

GE Measurement & Control

GE Measurement & Control GE Measurement & Control Psyclone Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. C August 2013 Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

Owner s Manual Humiport 10/20

Owner s Manual Humiport 10/20 4201 Lien Rd Madison, WI 53704 Owner s Manual Humiport 10/20 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Humiport line of ThermoHygrometers offers the restoration

More information

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007) GE Sensing Psyclone TM Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. A (September 2007) Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses

More information

Getting to know your Sureshotgps micro V3

Getting to know your Sureshotgps micro V3 Getting to know your Sureshotgps micro V3 Battery State Symbol Satellite Signal Shows distance to front, centre and rear of each green Hole Number Real Time Power on and Enter Key Down (backward) Key 1

More information

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free EM151/EM201 Electronic Manometer INSTRUCTION MANUAL - + PSI EM201 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com TABLE OF CONTENTS

More information

RAM 4021 Operation Manual

RAM 4021 Operation Manual RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6

More information

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read

More information

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION

More information

Golf Performance Monitors. PureContact Operating Guide. Version of 9

Golf Performance Monitors. PureContact Operating Guide. Version of 9 PureContact Operating Guide Version 5.1 www.zelocity.com 1 of 9 PureContact Metrics: Measured Ball Velocity Carry Distance Other PureContact Features: Instantly, Accurately Displays & Records Critical

More information

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT 2013 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected.

More information

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL.    EM201 PSI EM151/EM201 Electronic Manometer INSTRUCTION MANUAL - + PSI EM201 www.ueitest.com Email: info@ueitest.com TABLE OF CONTENTS Safety Rules..............................................2 Features.................................................3

More information

PTB210 Series Digital Barometers with Analog Output USER'S GUIDE

PTB210 Series Digital Barometers with Analog Output USER'S GUIDE PTB210 Series Digital Barometers with Analog Output USER'S GUIDE M210670en-A December 2004 PUBLISHED BY VAISALA Oyj Phone (int.): (+358 9) 894 91 P.O. Box 26 Telefax: (+358 9) 894 9227 FIN-00421 Helsinki

More information

USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B

USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B USER'S GUIDE Digital Barometers with Analog Output PTB210 Series M210670EN-B PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our

More information

Heavy Duty Dissolved Oxygen Meter

Heavy Duty Dissolved Oxygen Meter User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations

More information

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E E N2 Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE R218M06 Industrial R218M06 Rev. E Maxtec TEL (801) 748. 5355 2305 S 1070 W FAX (801) 270. 5590 Salt Lake City, Utah 84119 www.maxtec.com USA CLASSIFICATION

More information

TABLE OF CONTENTS 9.0 WARRANTY OI-XXXXXX

TABLE OF CONTENTS 9.0 WARRANTY OI-XXXXXX OI-XXXXXX 9.0 WARRANTY ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Hand-held pressure calibrator with integrated pump Model CPH6600

Hand-held pressure calibrator with integrated pump Model CPH6600 Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control

More information

PM105 PRESSURE METER USER S MANUAL

PM105 PRESSURE METER USER S MANUAL PM105 PRESSURE METER USER S MANUAL Manual revision: 15 March, 2001 SCSMANP015 Copyrighted 2001 Thank you for purchasing a Tek Know pressure meter. The Tek Know products are manufactured by Scan-Sense AS

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

Research Grade Blood Pressure Transducer User's Manual

Research Grade Blood Pressure Transducer User's Manual Research Grade Blood Pressure Transducer User's Manual Research Grade Blood Pressure Transducer, 110 VAC/60 Hz MA1 60-3002 Research Grade Blood Pressure Transducer, 220 VAC/50 Hz MA1 60-3003 WEEE/RoHS

More information

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Portable Gas Monitor GX User Maintenance Manual (H4-0050) H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to

More information

2 LE RHÔNE TABLE OF CONTENANT

2 LE RHÔNE TABLE OF CONTENANT USER MANUAL ENGLISH 2 LE RHÔNE TABLE OF CONTENANT Introduction 4 Accuracy and Precautions for Use 4 Water-resistance 4 Quality Test 4 Timepieces 5 HAUTE HORLOGERIE SERIES 6 ROAD RACER SERIES 8 HEDONIA

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark ECHO MANUAL L B A ltim e te rs ECHO is a trademark of LB Altimeters, Denmark LB Altimeters operates a policy of continuous development Therefore, we reserve the right to make changes and improvements to

More information

In Vivo Scientific, LLC INSTRUCTION MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3

More information

Digital pressure gauge Model CPG500

Digital pressure gauge Model CPG500 Calibration technology Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 Applications Calibration service companies and service industry Measurement and control laboratories Quality assurance

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product. Instruction Manual Hydraulic Punch Driver 902-483 LIMITED 1 YEAR WARRANTY We make every effort to assure that its products meet high quality and durability standards, and warrant to the original purchaser

More information

Operation Manual. O2 Quickstick. Oxygen Analyzer

Operation Manual. O2 Quickstick. Oxygen Analyzer Operation Manual O2 Quickstick Oxygen Analyzer 01.11 www.nuvair.com If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard, CA 93030 Phone: 805-815-4044

More information

WARRANTY, QUICK START GUIDE

WARRANTY, QUICK START GUIDE WARRANTY, QUICK START GUIDE ONE-YEAR LIMITED PRODUCT WARRANTY BABOLAT warrants to the original purchaser that the BABOLAT PLAY PURE DRIVE (the Product ) is free from defects in material or workmanship,

More information

Manufactured by: AAA

Manufactured by: AAA Manufactured by: AAA The Altitron Skydiving Altimeter is an advanced digital altimeter. It is designed to effectively improve safety and easily keep track of skydiving activity. It can be used as a mechanical

More information

Optical Dissolved Oxygen Meter

Optical Dissolved Oxygen Meter Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital, weighted probe No membranes No electrolytes No oxygen consumption No flow dependence

More information

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000

More information

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR Model HEM-412C TABLE OF CONTENTS Introduction 3 Know Your Unit 4 Quick Reference Guide 5 Battery Installation/Replacement 6 How To Apply The Arm

More information

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17 Operation Manual O2 Quickstick Oxygen Analyzer 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044 FAX:

More information

MODEL 100 NITROGEN INFLATION CART

MODEL 100 NITROGEN INFLATION CART MODEL 100 NITROGEN INFLATION CART Installation & Operation Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV120106 P/N: 81-0113 TABLE OF CONTENTS SAFETY

More information

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide CP-D/CP-M Circular Polarizer for Phoroptor User s Guide 2016 AMETEK, Inc. Reichert, Reichert Technologies, Auto Phoroptor RS and Phoroptor are registered trademarks of Reichert, Inc. Ultramatic RX Master

More information

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6 COMBAT SWIM BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International Feb 1, 2017 12 TAC-300 Revision 6 RJE International, Inc. 15375 Barranca

More information

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions CONUS MSR0680 UNDERWATER LIGHT Registered Community Design Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light CONUS MSR0680... 4 Power

More information

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4 COMBAT SWIM BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International January 16, 2017 RJE International, Inc. 15375 Barranca Pkwy, Ste. I-112,

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

OPERATING INSTRUCTIONS V 5.3

OPERATING INSTRUCTIONS V 5.3 1 OPERATING INSTRUCTIONS V 5.3 DM 06/ 07 EGO 06/ 07 ION /SP8 MINI Proto Matrix 07 Proto Rail Shocker Seventh Element, Inc WARNING Failure to follow directions may result in damage to board. Do not pull

More information

Agilent Flowmeter ADM1000

Agilent Flowmeter ADM1000 Agilent Flowmeter ADM1000 Operating Instructions Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) WARRANTY CLAUSE METROSONICS warrants each new cl-304 manufactured and sold to be free from defects in material, workmanship and construction, except for batteries which may be contained therein, and that

More information

SPECIFICATIONS APCEPH1

SPECIFICATIONS APCEPH1 APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x

More information

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please

More information

6 digital caliper with case

6 digital caliper with case 6 digital caliper with case Model 98563 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

PPS PORTABLE POWER SUPPLY

PPS PORTABLE POWER SUPPLY PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety

More information

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev Operation Manual Pro CO 2 Analyzer Carbon Dioxide Analyzer Rev. 10.17 Quick Reference Guide READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display powers up. 2. To turn

More information

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA Calibration Guide Model SM/PL Series Precision Loads Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA Part Number: 10100-00056 Revision: B Published: January 2010 Copyright 2009-2010 Anritsu

More information

SMART Oxygen Analyzer. User Manual

SMART Oxygen Analyzer. User Manual SMART Oxygen Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 NITROXBUDDY2 OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 3 6 SETTINGS... 4 6.1 BUTTON... 4 6.2 DISPLAY...

More information

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1) ENGLISH ENGLISH ENGLISH ENGLISH Installation user s manual Warning! electrical scheme modified JANUARY 2005 version 3.3 JOLLY2 DATA TO BE FILLED OUT BY THE INSTALLER (Page 1) 6 different operating modes

More information

The Univentor 1250 Anaesthesia Unit

The Univentor 1250 Anaesthesia Unit THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2

More information

Instruction Manual Model Borehole Pressure Cell

Instruction Manual Model Borehole Pressure Cell Instruction Manual Model 3200 Borehole Pressure Cell No part of this instruction manual may be reproduced, by any means, without the written consent of Geokon, Inc. The information contained herein is

More information

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual Bante820 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante820 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante820 portable dissolved oxygen

More information

SMART Carbon Monoxide Analyzer. User Manual

SMART Carbon Monoxide Analyzer. User Manual SMART Carbon Monoxide Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 MONOX OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 3 6 SETTINGS... 4 6.1 BUTTON... 4 6.2 DISPLAY...

More information

ANALOX ATA - Trimix Analyser. Technical Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

ANALOX ATA - Trimix Analyser. Technical Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK ANALOX ATA - Trimix Analyser Technical Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net

More information

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000

More information

Precision digital pressure gauge Model CPG1000

Precision digital pressure gauge Model CPG1000 Calibration technology Precision digital pressure gauge Model CPG1000 WIKA data sheet CT 10.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service

More information

Please Do Not Return This Product To The Store!

Please Do Not Return This Product To The Store! MODEL NUMBER: GM000W - GAMEMAKER TORCH O W N E R ' S M A N U A L PLEASE READ AND FOLLOW THIS MANUAL IN ITS ENTIRETY BEFORE USE. DOING SO WILL PROVIDE HELPFUL HINTS THAT WILL AID IN GETTING MAXIMUM USE

More information

Digital Vacuum Regulator

Digital Vacuum Regulator Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model DVR-380 INDEX SECTION PAGE SAFETY NOTICES................................................. 3 1. QUICK OPERATING

More information

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17 Operation Manual Pro He Alarm TM Helium Analyzer Rev 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1800-75 Respiration Test Chamber Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA

More information

OPERATION MANUAL FOR VP 710E-3HM SERIES ALLIGATOR TUMBLE STIRRERS *US Patent # 6,176,609

OPERATION MANUAL FOR VP 710E-3HM SERIES ALLIGATOR TUMBLE STIRRERS *US Patent # 6,176,609 TECHNICAL NOTE 299 OPERATION MANUAL FOR VP 710E-3HM SERIES ALLIGATOR TUMBLE STIRRERS *US Patent # 6,176,609 WARNING!!!!! Be advised that the Magnetic Tumble Stirrer has very strong magnetic fields coming

More information

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc. Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up

More information

WARNING: Read this manual in it s entirety before using this product. Improper use could result in damage to the product or lead to injury.

WARNING: Read this manual in it s entirety before using this product. Improper use could result in damage to the product or lead to injury. USER GUIDE 1 2015 Saris Cycling Group, Inc. 5253 Verona Road Madison, WI 53711 All rights reserved. No part of this publication may be copied, photographed, reproduced, translated, transmitted electronically

More information

Multifunction Altimeter/Variometer AV1

Multifunction Altimeter/Variometer AV1 Multifunction Altimeter/Variometer AV1 Revision#3.0, 21/11/2014 For firmware version 2.2 Page intentionally left blank SECTIONS MECHANICAL INSTALLATION ELECTRICAL INSTALLATION USE OF THE INSTRUMENT INSTRUMENT

More information

THIS IS AN ADULT AIRGUN AND ACCORDING TO ASTM STANDARDS, IT IS EXEMPT FROM HAVING A SAFETY.

THIS IS AN ADULT AIRGUN AND ACCORDING TO ASTM STANDARDS, IT IS EXEMPT FROM HAVING A SAFETY. Owner's Manual 586 and 686 Series CO2 Air Revolver cal..177 (4.5 mm) Pellet Pat. applied for This airgun is recommended for adult use only. Careless use may cause serious injury or death. Dangerous within

More information

KERN YDB-03 Version /2015 GB

KERN YDB-03 Version /2015 GB KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating manual Universal density determination

More information

ELECTRONIC PRINTING CALCULATOR OPERATION MANUAL CONTROLS AND OPERATIONS 5 CALCULATION EXAMPLES P a g e

ELECTRONIC PRINTING CALCULATOR OPERATION MANUAL CONTROLS AND OPERATIONS 5 CALCULATION EXAMPLES P a g e ELECTRONIC PRINTING CALCULATOR OPERATION MANUAL CONTROLS AND OPERATIONS 5 CALCULATION EXAMPLES..24 1 P a g e WARNING FCC Regulations state that any unauthorized changes or modifications to this equipment

More information

M104 Series: Digital Manometer: 0.1 % of Full Scale

M104 Series: Digital Manometer: 0.1 % of Full Scale M104 Series: Digital Manometer: 0.1 % of Full Scale Copyright 2008 Meriam Content M104 Series: Digital Manometer:...1 0.1 % of Full Scale...1 Content... 2 General information...4 Glossary... 5 General

More information

Digital pressure gauge Model CPG500

Digital pressure gauge Model CPG500 Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control laboratories Quality

More information

SPS-5. Rate Computing Scale. Operation Manual

SPS-5. Rate Computing Scale. Operation Manual SPS-5 Rate Computing Scale Operation Manual Revision 1.0 October 17, 1996 1996 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway Buffalo

More information

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC # E X R A D I N Spherical Ion Chambers A3. A4 REF 92717. 92715 R DOC #80360-00 E X R A D I N Spherical Ion Chambers A3. A4 REF 92717. 92715 STANDARD IMAGING INC. 7601 Murphy Drive Middleton, WI 53562 TEL

More information

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Bante821 Portable Dissolved Oxygen Meter Instruction Manual Bante821 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante821 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante821 portable dissolved oxygen

More information

Ages 6+ Item No INSTRUCTIONS. Get a Tiger! Get the Roar!

Ages 6+ Item No INSTRUCTIONS. Get a Tiger! Get the Roar! Ages 6+ Item No. 42792 TM INSTRUCTIONS Get a Tiger! Get the Roar! Read the instructions below, plug in your Paintball Trainer, and get ready for some fast blasting action! Begin by sharpening your skills

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

TrekMill USER'S MANUAL MM5050

TrekMill USER'S MANUAL MM5050 Read the safety and comfort guide in this manual before using this equipment. USER'S MANUAL TrekMill MM5050 Serial Number: Date Purchased: Find the serial number in the location shown below. CONTENTS Safety

More information

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions METEOR LSR36500 UNDERWATER POOL LIGHT Operating Instructions LIGHTING CONTENTS Preface...3 Features...3 Precautions...3 Components and Connectors...4 Installation...5 Controls...7 Appearance...8 Technical

More information

Instruction Manual Dräger MSI P7 and MSI P7 plus

Instruction Manual Dräger MSI P7 and MSI P7 plus Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 923; Edition 2011-01-01 Content 1. General Hints Page 4 2. The Instrument 2.1 Front

More information

Pneumatic service kit Model CPG-KITP

Pneumatic service kit Model CPG-KITP Calibration technology Pneumatic service kit Model CPG-KITP WIKA data sheet CT 93.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service industry

More information

CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE for the DG-700 Pressure and Flow Gauge The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE The Energy Conservatory 2801 21 st Ave. S., Suite 160 Minneapolis, MN 55407 Ph.: (612) 827-1117

More information

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10 DIVER NAVIGATION BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International Feb 1, 2017 12 TAC-100D Revision 10 RJE International, Inc. 15375 Barranca

More information

Modular skylight warranty

Modular skylight warranty Modular skylight warranty Specific limited product warranty 10 year limited warranty (a) (b) (c) VELUX insulating glass For a period of (10) ten years from the date of purchase, VELUX warrants to the end-user

More information

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps D Alcotest 6510 Breath Alcohol Screening Device Operator Instructions for Use ST-207-2004_sw.eps Contents Contents................................................. 2 For your safety............................................

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions

More information

Digital Vacuum Regulator

Digital Vacuum Regulator Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model DVR-280 INDEX SECTION PAGE 1. QUICK OPERATING INSTRUCTIONS............................. 3 KEM-NET DATA LOGGING

More information

INSTRUCTIONS warranty watch care

INSTRUCTIONS warranty watch care INSTRUCTIONS warranty watch care Congratulations on the purchase of your Szanto timepiece! Please read and follow the watch care instructions carefully to ensure that you are able to enjoy your timepiece

More information

ZORE-X. CORE SERIES 9x19. Owner s Manual. Watch the video before initial use

ZORE-X. CORE SERIES 9x19. Owner s Manual. Watch the video before initial use ZORE-X CORE SERIES 9x19 Owner s Manual Watch the video before initial use www.zore.life/firstuse This booklet is designed to provide information on how to properly install and remove your ZØRE-X lock.

More information

Lifeloc FC10. Operations Manual. Unlock the Power of Alcohol Testing

Lifeloc FC10. Operations Manual. Unlock the Power of Alcohol Testing Operations Manual Unlock the Power of Alcohol Testing Table of Contents 2 Table of Contents Introduction Congratulations...4 Front View... 5 Features...6 Preparation Installing Batteries... 7 Turning the

More information

Prestan professional Training manikin

Prestan professional Training manikin Prestan professional Training manikin Use and Care Instructional Sheet Models PP-AM-100M and PP-AM-400M > Prestan Professional Adult CPR-AED Training Manikin (with CPR Monitor) w/ 10 A/C face-shield lung

More information

SUUNTO ELEMENTUM AQUA USER GUIDE

SUUNTO ELEMENTUM AQUA USER GUIDE SUUNTO ELEMENTUM AQUA USER GUIDE en A B SETTINGS MEMORY DIVE TIME Functions: _Time, date, alarm _Backlight _Auto dive mode _Depth, max. depth _Dive time _Surface time _Water temperature _Number of dives

More information

RAM 4021-DPX Operation Manual

RAM 4021-DPX Operation Manual RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...

More information

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y Check and Go Disposable Operating Manual 2005 Medical Depot, Inc Port Washington N.Y. 11050 visit us at www. drivemedical.com Check and Go Disposable Part# 18580 2005 Medical Depot, Inc Port Washington

More information