MICRO DIAPHRAGM GAS PUMPS

Size: px
Start display at page:

Download "MICRO DIAPHRAGM GAS PUMPS"

Transcription

1 MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP83KNE NMP85KPDC NMP85.1.2KPDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves up and down its central point by means of an eccentric. In this way the gas is transferred using automatic valves. The pumps are equipped with the stress-optimized diaphragm, resulting in a high pneumatic performance, a durable product and compact size. In addition special valves ensure the minimum resistance to flow. Thanks to the KNF modular system, the parts used to transfer the gases can be made from materials with varying degrees of resistance. The pumps can be driven by either AC or DC motors. Features Uncontaminated flow No contamination of the media due to oil-free operation Maintenance-free Compact size High pneumatic performance Low aerodynamic loss High level of gas tightness Long product life Ready for assembly Can operate in any installed position For the version with brushless motor the following also apply: safe and reliable constant use particularly long durability Connection hose bs. Optional M5, UNF 1/4.-28, DN4/6 mm hose connector Areas of use KNF micro diaphragm pumps are used frequently in the fields of analysis and medicine. For instance as pumps for gas measurement, for example for sampling environmental conditions in the workplace, or for exhaust gas and smoke analysis or built into machines for measuring blood pressure. The AC models are suited for use in machinery which is permanent or mainsoperated. Micro diaphragm pumps for portable and stand-alone equipment require DC power supplies. (l/min) Vacuum (m absolute) atmospheric pressure Pressure () NMP83KNE NMP83KNDC-B NMP83KNDC NMP85KPDC-B NMP85KPDC NMP85.1.2KPDC-B Weight (g)

2 NMP83K_E at atm. pressure (l/min) Max. operating pressure () NMP83KNE NMP83KVE NMP83KTE MOTOR DATA Protection class IP Voltage 23 Frequencies (Hz) 5 Power P1 (W) 25 lmax (A).3 (m abs.) Pump head Diaphragm Valves NMP83KNE PPS EPDM CR NMP83KVE PPS FPM FPM NMP83KTE PPS PTFE-coated FFPM NMP83K_DC DC motor (l/min) () NMP83KNDC NMP83KVDC NMP83KTDC NMP83KNDC NMP83KVDC NMP83KTDC NMP83KNDC NMP83KVDC NMP83KTDC (m abs.) Pump head Diaphragm Valves NMP83KNDC PPS EPDM CR NMP83KVDC PPS FPM FPM NMP83KTDC PPS PTFE-coated FFPM NMP83KNE NMP83KVE m NMP83KNDC m NMP83KTE NMP83KVDC m m NMP83KTDC m

3 NMP83K_DC-B KNF DC motor, brushless at atm. pressure (l/min) Max. operating pressure () NMP83KNDC-B NMP83KVDC-B NMP83KTDC-B NMP83KNDC-B NMP83KVDC-B NMP83KTDC-B (m abs.) NMP85K_DC DC motor (l/min) () NMP85KPDC NMP85KTDC NMP85KPDC NMP85KTDC (m abs.) Pump head Diaphragm Valves NMP83KNDC-B PPS EPDM CR NMP83KVDC-B PPS FPM FPM NMP83KTDC-B PPS PTFE-coated FFPM Pump head Diaphragm Valves NMP85KPDC PPS EPDM EPDM NMP85KTDC PPS PTFE-coated FFPM NMP83KNDC-B 3. NMP85KPDC m NMP83KVDC-B m NMP85KPDC m NMP83KTDC-B m m

4 NMP85K_DC-B KNF DC motor, brushless (l/min) () NMP85KPDC-B NMP85KTDC-B 12 3 NMP85KPDC-B NMP85KTDC-B 24 3 (m abs.) NMP85.1.2KPDC-B KNF DC motor, brushless (l/min) () (m abs.) NMP85.1.2KPDC-B NMP85.1.2KPDC-B Pump head Diaphragm Valves NMP85KPDC-B PPS EPDM EPDM NMP85KTDC-B PPS PTFE-coated FFPM Pump head Diaphragm Valves NMP85.1.2KPDC-B PPS EPDM EPDM NMP85KPDC-B m.5 1. NMP85KTDC-B NMP85.1.2KPDC-B m m.5 1.

5 HINTS ON FUNCTION AND INSTALLATION Function of KNF micro diaphragm gas sampling pumps An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuate and compress completely oil-free. Hints on installation and operation Range of use: Transferring air and gases at temperatures between +5 C and +4 C. Please check the compatibility of the materials of the pump head, diaphragm and valves with the medium. The KNF product line contains pumps suitable for pumping aggressive gases and vapors please contact us. Permissible ambient temperature: between +5 C and +4 C. The standard pumps are not suitable for use in areas where there is a risk of explosion. In these cases there are other products in the KNF program please ask us for details. The pumps are not designed to start against pressure or ; when a pump is switched on the pressure in the suction and pressure lines must be atmospheric. Pumps that start against pressure or are available on request. To prevent the maximum operating pressure being exceeded, restriction or regulation of the air flow should only be carried out in the suction line. For the version with brushless motor the following also apply: Caution! Incorrect lead connection will damage motor electronics! Install the pump so that the fan can draw in sufficient cooling air. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Fit the pump at the highest point in the system, so that condensate cannot collect in the head of the pump that prolongs working-life. Accessories Description Order No. Details Filter/silencer 2485 for NMP 83 KNF reserves the right to make changes.

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP 83 KNE NMP 85 KNDC NMP 85.1.2 KNDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 010 N 89 KNDC N 811 KNE N 814 KNE Concept The mini diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

MINI DIAPHRAGM VACUUM PUMPS

MINI DIAPHRAGM VACUUM PUMPS MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET E 059 N 0150 AP.9E N 0150.3 AP.9E N 0150 SP.12E Double diaphragm pump Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm,

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

MINI DIAPHRAGM VACUUM PUMPS

MINI DIAPHRAGM VACUUM PUMPS MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge,

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 0150 N 0150 SP.9 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central point

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 23 N 26.1 ANE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 16 N 35 ANE with IP 2 motor Concept The diaphragm pumps from KNF are based on a simple principal - an elastic diaphragm, ixed on its edge, moves up and

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 14 N 22 ANE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 015 N 920 APE-W Automatic voltage adjustment for worldwide use (as an option with external signal input). N 920 APDC-B with brushless DC

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 9 N 9 FTE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

Willkommen. Welcome to KNF - presentation

Willkommen. Welcome to KNF - presentation Willkommen Welcome to KNF - presentation KNF modular system, way to Project pump heads available in: - aluminium - plastics (PPS, Peek ) - stainless steel - PTFE diaphragms und valves available in: - Neopren

More information

MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM

MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM DATA SHEET E 081 N 86 AN.12DC-B Concept Double diaphragm pumps from KNF are based on a simple principle: an elastic working membrane and safety membrane

More information

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM DATA SHEET E065 Cutaway - Double diaphragm pump Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E030 N 145.2 ANE Concept The Diaphragm Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and down its

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Diaphragm Vacuum Pumps and Compressors N 022 ANE N 026 ANE N 026.1 ANE N 026.2 ANE N 026.3 ANE N 022 AN.9 E N 026 AN.9 E N 026.1 ATE N 026.2 ATE N 026.3 ATE N 022 ATE N 026 ATE N 026.1 AVE N 026.2 AVE

More information

Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and

Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E N 143 SN.12 E N 143 SV.12 E Operating and Installation Instructions Read and observe these Operating and Installation

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

Diaphragm Vacuum Pump

Diaphragm Vacuum Pump Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pump N920 AP.18 N920 AP.29.18 N920 KT.29.18G KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Phone +49-(0)7664

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS N26.1, N26.2, N26.3 N 26.1 ANE Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 26, LEM 51 Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 PROCESS Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 Single & Twin-Head Designs OEM Installation Models UN860FTI EX UN726.3STI EX UN726.3FTI

More information

Compressed Airline Breathing Apparatus

Compressed Airline Breathing Apparatus Compressed Airline Breathing Apparatus [ The Independence in Breathing] The Complete Range at a Glance Full face mask with lung governed demand valve Light duty airline breathing apparatus Cavair LDA Pressure

More information

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP 00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

SuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems.

SuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems. Available versions Spraypack Basic unit 0341 051 basic unit on trolley including pressure gauge system + QuickClean suction + 15 m high pressure hose + Airless gun G 12 + Wagner Tip holder with Airless

More information

Operating Manual VSA100A. tina29e1 ( )

Operating Manual VSA100A. tina29e1 ( ) Operating Manual Incl. EU Declaration of Conformity Vacuum Switch VSA100A tina29e1 (2017-05) 1 Product Identification In all communications with INFICON, please specify the information on the product nameplate.

More information

Squeegee Unit for MRS Multi-Recovery System

Squeegee Unit for MRS Multi-Recovery System En Operating Instructions Squeegee Unit for MRS Multi-Recovery System Translation of the original operating instructions Squeegee - MRS Table of Contents Safety Recommendations Technical Data - MRS Booth

More information

Airless-spraying equipment. SuperFinish 23. Solid. Profitable. Innovative QLS technology

Airless-spraying equipment. SuperFinish 23. Solid. Profitable. Innovative QLS technology Airless-spraying equipment SuperFinish 23 Solid Profitable Innovative QLS technology The easily transported Airless spraying equipment for flexible use on the building site Innovative QLS technology reliable

More information

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet Automatic Control Unit Cervomatic EDP.2 Type Series Booklet Legal information/copyright Type Series Booklet Cervomatic EDP.2 All rights reserved. The contents provided herein must neither be distributed,

More information

High Pressure Breathing Air Compressors

High Pressure Breathing Air Compressors High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,

More information

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX This new range of multiple ejector vacuum generators represents the natural evolution of the PVP 12M and 25M generators. In fact, given the same air consumption

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology Airless-Spraying Equipment SuperFinish31 Fully equipped More power Innovative QLS technology New technology, fully equipped with even more power. This is the new SuperFinish 31 Airless spraying equipment,

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

evoguard The valve series for aseptic applications

evoguard The valve series for aseptic applications The valve series for aseptic applications Safety first Microbiologically sensitive products need to be treated with special care. The highest safety along the entire product handling chain is needed to

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement

More information

A17W49_MASEM_F_EN MANUAL

A17W49_MASEM_F_EN MANUAL AW9_MASEM_F_EN MANUAL CONTENTS Identification. Manufacturer. Product name. Year of manufacture. Area of use. Declaration of conformity Technical specification. Design. Function. Technical data. Electrical

More information

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100 MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET /1.100 / 1.100 KP.51 DC NF 1.100 KPE KP.27 AA Concept KNF diaphragm liquid pumps are based on the principle of the oscillating displacement pump which is remarkably

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

Pressure independent control valve (PICV) FLOWMATIC

Pressure independent control valve (PICV) FLOWMATIC Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow

More information

ACTUATORS AND INSTRUMENTS

ACTUATORS AND INSTRUMENTS ACTUATORS AND 03 ADVANCED ACTUATORS AND FOR A COMPLETE VALVE CONTROL SOLUTION Koso Kent Introl LIMITED (KKI) supplies a full range of advanced actuators and associated instrumentation to complement its

More information

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of

More information

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

TECHNOLOGIES. M Series. Positive return metering pumps [API675] M Series Positive return metering pumps [API675] Hydraulic double diaphragm metering pump in AISI 316L stainless steel A line of plunger and hydraulic double diaphragm metering pumps designed according

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media

More information

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm > Series CGPT self-centering parallel grippers with T-guide Series CGPT self-centering parallel grippers with T-guide Single and double acting, magnetic, self-centering Bores: ø 6, 20, 25, 32, 40 mm New

More information

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic

More information

kysimply Unique Single Seat

kysimply Unique Single Seat . kysimply Unique Single Seat Unique SSV Long Stroke General Information The new generation that meets the highest demands of your process in terms of hygiene and safety. Unique Single Seat Valves are

More information

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 750 set range: bar Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long

More information

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at

More information

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this INSTRUCTION MANUAL AIRBRUSH COMPRESSOR AS-48A Thanks for purchasing our airbrush compressor and please read this Instruction Manual carefully and thoroughly before operating the tool to get best performance.

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve Series Self-operated Pressure Regulators Type -6 B Excess Pressure Valve Application Set points from 0.2 to 20 bar with valves G ½, G ¾, and G as well as DN, DN 2, DN 0, and DN 0 Nominal pressure PN 2

More information

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX COMPLIANCE ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX compliance pursuant to Directive 94/9/EC for its ranges of ADB BOXER pneumatic diaphragm pumps.

More information

Atlas Copco Tools & Assembly Systems. Air Line Accessories Optimizers- FRL

Atlas Copco Tools & Assembly Systems. Air Line Accessories Optimizers- FRL Atlas Copco Tools & Assembly Systems Air Line Accessories Optimizers- FRL MIDI Optimizer FRL Why use an Atlas Copco FRL? Atlas Copco filters, regulators, and lubricators are designed to help you get maximum

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

Valvex Valves for Mining Applications

Valvex Valves for Mining Applications Valvex Valves for Mining pplications roven technology The Electronic Drive Systems product group at Voith Turbo GmbH & Co. KG develops and produces explosion-proof Valvex solenoid valves and valve assemblies.

More information

ELADOS EDP L Diaphragm Metering Pump Type

ELADOS EDP L Diaphragm Metering Pump Type ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably

More information

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic Pharmaceutical SRL Series Oil-less Scroll Air Compressors Research & Development Food & Beverage Chemical Electronic Hitachi Industrial Equipment Product Brochure Hitachi SRL Series scroll compressors

More information

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E Operating and Installation Instructions Read and observe these Operating and Installation Instructions! Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N 0150.1.2

More information

LIQUID PUMPS ACCESSORIES OVERVIEW

LIQUID PUMPS ACCESSORIES OVERVIEW LIQUID PUMPS ACCESSORIES OVERVIEW INDEX Pulsation damper, FPD 06 3 Pulsation damper, FPD 10 4 Pulsation damper, UFPD 06 5 Pulsation damper, UFPD 10 6 Pressure control valves, FDV 30 7 Pressure control

More information

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

Operating Instructions

Operating Instructions Operating Instructions Type TEKA Ventilator TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72

More information

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0127 Rocker valve 2/2 or 3/2-way solenoid valve 2/2 oder 3/2-Wege Magnetventil Vanne magnétique 2/2 ou 3/2 Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions...2

More information

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings CAT.E832- A Air Suction Filter In-line Type with One-touch Fittings Series ZFC An in-line type air suction filter that prevents trouble in vacuum equipment due to contaminants in the air IN/OUT straight

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors

More information

Pre-filter for Brushless Blower Instruction Manual

Pre-filter for Brushless Blower Instruction Manual Pre-filter for Brushless Blower 781-70-702 Instruction Manual Minebea Co., Ltd. Industrial Machinery Business Unit 251-8531 1-1-1 Katase,Fujisawa,kanagawa Contact Us Industrial Machinery Product Sales

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum. This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum. Specifically, today s talk will cover: Brief review of Vacuum Fundamentals Applications Using Rough Vacuum Rough

More information

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems Pneumatic Retractable Fittings SensoGate WA 3 Pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation SensoGate WA 3 offers genuine plug & play. The

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING

More information

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301 DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV 1.300 / 1.301 FDV 31 KP Z A: Pump Accessories KP/KP.51 / KV / KT / TV / TT 30 / 1.30 / 31 / 1.31 / 300 / 1.300 / 301 / 1.301

More information

II 2G EEx ia IIC T6. Ignition protection class

II 2G EEx ia IIC T6. Ignition protection class ATEX General information According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm.

More information

Model range*1) Switching pressure difference

Model range*1) Switching pressure difference Pneumatic pressure switch electromechanical actuated -...00 bar, G/2 Microswitch with gold plated contacts Intrinsically safe operation Electrical connection: connector acc. to IN EN 7530-803 (form A)

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections

More information

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min Compact Ejectors Suitability for Industry-Specific Applications Applications Handling of air-tight as well as porous workpieces supply and vacuum monitoring in automated systems For use in sheet metal

More information

Basic & Controlled Atmosphere Glove Boxes

Basic & Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical

More information

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes MPG-plus Sizes 25 40 Weight 0.06 kg 0.24 kg Gripping force 38 N 175 N Stroke per finger 3 mm 6 mm Workpiece weight 0.19 kg 0.7 kg Application example Pneumatically driven, dual-axis pick-and-place machine

More information

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 725 set range: 0,2-10,0 bar Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level

More information