Measurement & Analytics Wet gas monitoring

Size: px
Start display at page:

Download "Measurement & Analytics Wet gas monitoring"

Transcription

1 Product guide PG/FLOW/010-EN Measurement & Analytics Wet gas monitoring Economical wet gas metering using non-proprietary correlations Measurement made easy Introduction With many of the most economically attractive gas fields already on stream, the more-marginal fields must now be exploited, including gas condensate fields. Here the gas is the primary resource and only small amounts of hydrocarbon liquid are contained in the gas stream. Separation of the phases for allocation and well testing (for example) is often either not possible or uneconomic and there is a growing requirement for flow meters to either simply measure the gas flow or to measure both the liquid and gas phases. This leads some users to fall back on multiphase meters, which, because of their complexity, can be prohibitively expensive. A more economical solution to metering in many wet gas applications does exist. This guide describes the solution and the public-domain (non-proprietary), well-accepted algorithms / correlations that the solution employs, measuring the flowrates and total flow of both the liquid and gas phases. The metering of this wet gas is a difficult application that requires a special approach in both hardware and data processing. The presence of liquid in a gas stream affects the flow reading of a DP-based meter, giving a value higher than the true gas flowrate. This over-reading becomes greater as the Liquid Volume Fraction, (LVF) the ratio of liquid volume to total volume increases.

2 Measurement & Analytics Wet gas monitoring Wet gas is defined as a gas stream with liquids present. However, it is treated as single-phase flow measurement, in that it is predominately gas and it is measurement of the gas phase only that is required. The Gas Volume Fraction (GVF) is typically no less than 90 to 95 %, unlike in multi-phase metering where the gas fraction can be very much lower (the liquid fraction can be very much higher). Wet gas metering is differentiated from two-phase flow metering by the value of the Liquid Volume Fraction (LVF). When a gas carrying a liquid phase is measured with a DP flow meter (the most economical technology to use), energy is expended in trying to accelerate the liquid phase up to the gas velocity. This energy loss is manifested as a pressure drop through the meter. The DP measured therefore is higher than ISO5167, for example, predicts for a given meter, resulting in an over-reading of the gas volume. Accurate measurement of the gas phase is only possible using correction factors, that themselves will depend on the LVF and the physical properties of the liquid phase itself. Features and benefits ABB makes wet gas metering easy by leaving out the complications of other wet gas metering solutions: No specialty measurement required No need for flow calibration: ISO5167 meter design No patents, no secrets: everything is in the public domain No uncontrolled software No need for tracer dilution testing for liquid content determination The flow meter is constructed in accordance with ISO-5167 and ISO/TR 11583:2012, so flow calibration is not required, but is offered as an option. Because the basic system is as any other DP flow metering set-up, it is familiar to both operators and technicians and therefore requires no specialists for commissioning or servicing. All calculations of flow rate and PVT properties are contained within ISO documents and are performed by a flow computer. Furthermore, for pure liquids when assuming 100 % oil or water, costly tracer dilution tests are no longer required, as the system is able to calculate the liquid content in real-time, based on the ISO/TR algorithm. Fig. 1: Panel-mount wet gas flow computer 2 PG/FLOW/010-EN Measurement & Analytics Wet gas monitoring

3 In addition, the ABB wet gas metering system provides some interesting features: It is the only solution with PVT calculations carried out within the flow computer, so there is no need for a PC. It uses a real (compliant with API MPMS Chapter 21 and MID certified) flow computer: this is highly preferred by users for (fiscal) allocation metering Touch screen operation The degree of over-read of the net gas flow rate is affected by the following: Operating pressure The Lockhart-Martinelli parameter ( ), that represents the Liquid Volume Fraction (LVF). The Gas Froude number that represents the gas velocity in the pipe (Frgas) or meter restriction (Frgas,th) Capable of remote operation from laptops and tablets Fig. 2: External touch screen for flow computer To correct for the over-reading mentioned above, over time a number of correlations have been found. The original correlation was developed by Murdock for orifice plates and then modified by Chisholm to take account of the additional effects of the gas density. De Leeuw found another correlation for wet gas when measured by Venturi tubes. All these correlations involve a coefficient called the Lockhart-Martinelli parameter, a dimensionless number which expresses the LVF in terms of the pressure drops (across the meter restriction) of the liquid and gas phases flowing alone. Further work and corrections to these are detailed within ISO/TR 11583:2012 and the ABB solution uses these latest correlations. Fig. 3: Downstream tapping for overall pressure loss measurement Measurement & Analytics Wet gas monitoring PG/FLOW/010-EN 3

4 Measurement & Analytics Wet gas monitoring Venturi over-reading calculation The De Leeuw correlation calculates the over-reading ( ) the ratio of the uncorrected gas flowrate to the true gas flowrate: This correlation was established using Venturi meters with a gas stream containing hydrocarbon condensate. Since De Leeuw's original work, the correlation has been updated within ISO/TR 11583:2012 to: = (1 + CCh + 2 ) 1 /2 CCh is a complex function of the densities of the liquid and gas phases, the Beta ratio, Froude Number and a coefficient related to the liquid's surface tension. Venturi Lockhart Martinelli calculation The overall pressure loss across the meter can be used to evaluate the Lockhart Martinelli number ( ) for the application and Venturi tube. The position of the tapping downstream of the meter must be within a range whose limits depend on the Beta ratio and the pipe diameter. However this method is valid only for a certain range of values of the ratio of the actual pressure loss increase due to wetness and the maximum increase. These, in turn, are functions of the overall pressure loss, the meter DP, Beta ratio, gas and liquid phase densities, Froude Number and the liquid surface tension coefficient Note: ISO/TR applies only for a gas containing a single phase liquid (either hydrocarbon liquid/oil or water not for a mixture). Note that an accurate well stream composition needs to be established and entered in the flow computer, which then performs GERG-2008 calculations in real-time to determine all the necessary gas and liquid properties. ISO/TR 12748:2015 states that fluid composition estimates can be one of the largest source of uncertainty in the output of wet gas flow meters. Although in all other respects the Venturi tube is designed to ISO5167, the discharge coefficient when used on wet gas is calculated according to the ISO/TR standard, that includes modifications involving the values of Throat Froude Number and. Fig. 5: Typical system HMI display Fig. 4: Wet gas venturi tubes 4 PG/FLOW/010-EN Measurement & Analytics Wet gas monitoring

5 System components The Venturi tube is an ideal primary element to use in wet gas metering as it is less affected than most by the presence of liquid in a gas phase, as any liquid can pass easily through the meter without blockage or damage. A flow computer is the industry-accepted electronics platform for performing the necessary wet gas correction. The ABB wet gas solution incorporates both of these products. The flow computer is available in configurations for mounting in the field (with ATEX zone 2 or Class I Div 2 classification), on a panel, on a DIN rail or in a rack. The pressures and pressure differences are measured using pressure transmitters, differential pressure transmitters and/or multivariable transmitters. The temperatures are measured using RTD elements in thermowells and temperature transmitters. Fig. 7: DIN rail-mount flow computer Fig. 6: Rack-mount flow computer Fig. 8: Ex-certified field-mount flow computer with optional touchscreen Measurement & Analytics Wet gas monitoring PG/FLOW/010-EN 5

6 Measurement & Analytics Wet gas monitoring Limits of use The limitations of the experimental data used to create the correlations in turn impose limits on the field of application for the correction methods. These can be summarized as follows: Horizontal pipe runs only Venturi Beta ratio ( ) Lockhart Martinelli ( ) 0 < 0.3 Throat Gas Froude Number (Frgas,th) Frgas,th > 4 Ratio of gas density at upstream tapping to liquid density ( 1,gas / liquid) 0.02 < 1,gas / liquid 0.09 Pipe diameter D 250 mm (10 in.) D 50 mm (2 in.) System performance For operation within the limits of use specified by ISO/TR 11583, that standard specifies that the uncertainty of the correction factor for over-reading will be between 2.5 % and 6 %, depending on the value and uncertainty of. Applications Wet gas meters are used in a number of applications, including: Development of marginal oil and gas fields Process metering: where gas contains hydrocarbon liquid or water (or a mixture of the two) Allocation metering: enabling individual well control Well management Well testing: reducing CAPEX in evaluation of new wells Production optimization Mechanical specification Pressure class: ANSI Class to 2500# Process temperature range: 40 to 220 C ( 40 to 428 F) Typical flow meter body material: Duplex UNS S31803 (others on request) End connection: flanged, weld prep or hub type 6 PG/FLOW/010-EN Measurement & Analytics Wet gas monitoring

7 Certification, testing and documentation ABB wet gas meters are supplied with comprehensive certification and documentation and are subject to stringent testing. Material traceability certificates are supplied to ensure the quality and suitability of the material used in the manufacture of the flow elements. ABB offers testing of the materials used to produce the meter. The complete meter can also optionally be tested on water, gas or wet gas. In the past ABB have used the wet gas test facilities at CEESI (Colorado Engineering Experiment Station) in the USA for wet gas meter testing, but can equally collaborate with the customer's preferred test facility. ABB's extensive range of certification and testing is supported by comprehensive customer documentation packages. The data dossiers are tailored to the requirements of the project but include meter bore calculations, welding qualifications, drawings, NDE certificates & procedures, material certificates and quality plans. Measurement & Analytics Wet gas monitoring PG/FLOW/010-EN 7

8 Contact us ABB Limited Industrial Automation Salterbeck Trading Estate Workington Cumbria CA14 5DS UK Tel: +44 (0) Fax: +44 (0) Spirit Innovative Technologies (a member of the ABB Group) AM Eindhoven The Netherlands Tel: Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2017 ABB All rights reserved PG/FLOW/010-EN

Wet Gas Flowmetering Guideline

Wet Gas Flowmetering Guideline Wet Gas Flowmetering Guideline ASME MFC-19G 2008 THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS Three Park Avenue New York, New York 10016-5990 CONTENTS Foreword... v Standards Committee Roster... vi 1 Introduction...

More information

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,

More information

Flowatch Multiphase Flow Meter

Flowatch Multiphase Flow Meter Multiphase Flow Meter Multiphase Flow Meter Key Components Pietro Fiorentini's FLOWATCH is a non-intrusive, non radioactive, in-line multiphase meter for measuring flow rates of oil, water and gas from

More information

FPD175 Compact orifice carrier assembly

FPD175 Compact orifice carrier assembly ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION FPD175 Compact orifice carrier assembly The smart solution for remote applications. Measurement made easy Installation, commissioning and operating / maintenance

More information

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

CoriolisMaster mass flowmeter Diagnostics, verification and proof test ABB MEASUREMENT & ANALYTICS WHITE PAPER CoriolisMaster mass flowmeter Diagnostics, verification and proof test Automatic in situ verification of accuracy for CoriolisMaster mass flowmeters. By Frank Frenzel

More information

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE Acadiana Flow Measurement Society Gerald L. Morrison Presented by: Mechanical Engineering Department Daniel J. Rudroff 323 Texas A&M University Flowline Meters

More information

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Multiphase MixMeter. MixMeter specification. System Specification. Introduction System Specification Multiphase MixMeter Introduction The MixMeter is unique in applying proper homogenization techniques to multiphase measurement. In so doing the MixMeter avoids the requirement for

More information

THE WET-GAS TESTING OF TWO 8-INCH ORIFICE PLATES

THE WET-GAS TESTING OF TWO 8-INCH ORIFICE PLATES THE WET-GAS TESTING OF TWO 8-INCH ORIFICE PLATES A Report for National Measurement System Department for Innovation, Universities and Skills Kingsgate House 66-74 Victoria Street London SWE 6SW Project

More information

Wet Gas Measurement Using an etube Flow Meter

Wet Gas Measurement Using an etube Flow Meter Wet Gas Measurement Using an etube Flow Meter Brian Zerb, Zedi Inc. Edmonton, AB Introduction Wet metering of natural gas has been increasing in demand. As well productions decline and flow rates of new

More information

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost

More information

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible Change from one to two columns Technical Information TI/EDP300_ED-EN Rev. A PositionMaster EDP300 Extended Diagnostics Compact, well-proven, and flexible The benefits of the extended diagnostics feature

More information

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates Impact of imperfect sealing on the flow measurement of natural gas by orifice plates Rubens Silva Telles 1, Kazuto Kawakita 2 1 IPT Instituto de Pesquisas Tecnológicas, São Paulo, Brazil, rtelles@ipt.br

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 5167-5 First edition 2016-03-01 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 5: Cone meters

More information

Oil And Gas Office Houston Fax Test Separator / Off-Shore Metering

Oil And Gas Office Houston Fax Test Separator / Off-Shore Metering Oil And Gas Office Houston 281 361 0708 Fax 201 361 0708 Test Separator / Off-Shore Metering Prepared By : Mr. Phil Lawrence A. M. Inst Mech E. Sales Manager (Oil and Gas Industry) 2.0 Philosophy for Test

More information

GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK

GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK SPECIFICATION FOR GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK J510 ( Rev 04/06 ) OCTOBER 2005 . CONTENTS Page FOREWORD BRIEF HISTORY iii iii INTRODUCTION

More information

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate Restriction Orifice Single or Multi Stage Orifice to Reduce Pressure or Limit the Flow Rate Restriction Orifice Plates Series ROPS Principle Restriction Orifice Plates and Critical Flow Devices and their

More information

Service Calibration are you doing it properly?

Service Calibration are you doing it properly? ABB MEASUREMENT & ANALYTICS ARTICLE Service Calibration are you doing it properly? A variety of factors, including wear and tear and non-ideal installation conditions, can cause the performance of an instrument

More information

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide ABB MEASUREMENT & ANALYTICS PRODUCT GUIDE PG/SMD140 EN REV. B UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide Measurement made easy UKAS calibration laboratory

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 17089-1 First edition 2010-11-15 Measurement of fluid flow in closed conduits Ultrasonic meters for gas Part 1: Meters for custody transfer and allocation measurement Mesurage

More information

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation)

ISO/TR TECHNICAL REPORT. Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation) TECHNICAL REPORT ISO/TR 12148 First edition 2009-02-15 Natural gas Calibration of chilled mirror type instruments for hydrocarbon dewpoint (liquid formation) Gaz naturel Étalonnage des instruments du type

More information

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK. OFFICIAL SPONSOR PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK. ADVANCES IN HIGH CAPACITY CORIOLIS FLOWMETERS INTRODUCTION Rising Oil prices between 2005 to 2015 resulted

More information

Chapter 22 Testing Protocols

Chapter 22 Testing Protocols This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated

More information

EVALUATING AND IMPROVING WET GAS CORRECTIONS FOR HORIZONTAL VENTURI METERS

EVALUATING AND IMPROVING WET GAS CORRECTIONS FOR HORIZONTAL VENTURI METERS EVALUATING AND IMPROVING WET GAS CORRECTIONS FOR HORIZONTAL VENTURI METERS Alistair Collins, Dr. Mark Tudge, Carol Wade (Solartron ISA) [we are] dwarfs perched on the shoulders of giants...we see more

More information

The ERCB Directive 017 Overview

The ERCB Directive 017 Overview The ERCB Directive 017 Overview November 4, 2009 By Bill Cheung Why measure and report production, flaring, and venting? Public Safety and Environment Understand and monitor emissions Reservoir Engineering

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

TekValSys MP. Multi Phase Separator. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys TEKVALSYS

TekValSys MP. Multi Phase Separator.   Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys TEKVALSYS Technology Solutions TekValSys MP Multi Phase Separator TEKVALSYS Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction TekValSys MP Multi-Phase Separator performs continuous

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, Multivariable meter delivers mass flow, temperature, pressure, and density

More information

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources HOW TO NOT MEASURE GAS - ORIFICE Dee Hummel Targa Resources Introduction Measuring natural gas is both a science and an art. Guidelines and industry practices explain how to accurately measure natural

More information

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System JOURNAL ARTICLES BY FLUENT SOFTWARE USERS JA187 Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System Computer simulation has helped NATCO engineers make dramatic improvements

More information

Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters

Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters ABB MEASUREMENT & ANALYTICS WHITE PAPER Pressure measurement Applying remote seal, isolation diaphragms between process fluids and transmitters Remote seals protect transmitters when measuring difficult

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

Flare Gas Measurement in B.C., Alberta, and Saskatchewan Using GE Ultrasonic Metering Technology

Flare Gas Measurement in B.C., Alberta, and Saskatchewan Using GE Ultrasonic Metering Technology November 2017 Flare Gas Measurement in B.C., Alberta, and Saskatchewan Blaine Barnes Tundra Process Solutions www.tundrasolutions.ca 1 MEASUREMENT REGULATIONS With the creation of Directive PNG017 by the

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007 Overview ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007 ProSoft Technology s Gas and Liquid Flow Computer (AFC) products will comply with the requirements

More information

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs

9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs Data sheet DS/9408 EN Rev. M 9408 Series Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling design minimizes operational costs Low maintenance,

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions

More information

NEW VERSAFLOW CORIOLIS

NEW VERSAFLOW CORIOLIS Steffen Baecker June 20, 2017 NEW VERSAFLOW CORIOLIS With Stable Two-phase Flow Measurement Honeywell Internal VersaFlow Flow Technologies Volume flow measurement Conductive fluids only - Water - Chemicals

More information

General Specifications

General Specifications General Specifications GS 34P02P31-02E Gas Flow Calculation Portfolio (FCN-RTU) GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN-RTU low power autonomous

More information

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi

More information

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction ONSITE PROVING OF GAS METERS Daniel J. Rudroff WFMS Inc. 13901 West Bellfort Sugar Land, Texas Introduction With the increased use of Natural Gas as a fuel, and higher natural gas prices buyers and sellers

More information

General Specifications

General Specifications General Specifications GS 34P02P31-01E Gas Flow Calculation Portfolio (FCN-100/FCN-RTU/FCJ) GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN/FCJ autonomous

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop

More information

Performance Improvement of Large Installation base of Wellhead Venturi Wet Gas Measurement in Petroleum Development Oman (PDO)

Performance Improvement of Large Installation base of Wellhead Venturi Wet Gas Measurement in Petroleum Development Oman (PDO) Performance Improvement of Large Installation base of Wellhead Venturi Wet Gas Measurement in Petroleum Development Oman (PDO) Abdullah Al Obaidani, Khalil Al Hanashi, Hamed Al Hadhrami, Dawood Al Sulaimani

More information

The Evaluation of Dry Gas Meters in Wet Gas Conditions A Report for

The Evaluation of Dry Gas Meters in Wet Gas Conditions A Report for The Evaluation of Dry Gas Meters in Wet Gas Conditions A Report for National Measurement System Directorate Department of Trade & Industry 151 Buckingham Palace Road London, SW1W 9SS Report No: 2002/100

More information

Service ISO17025 explained

Service ISO17025 explained ABB MEASUREMENT & ANALYTICS ARTICLE Service ISO17025 explained The ISO17025 standard covers any organization offering testing and calibration services Measurement made easy Accredited laboratory for testing

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs. Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography

More information

OVERVIEW OF THE CONVAL 10 SERVICE RELEASES

OVERVIEW OF THE CONVAL 10 SERVICE RELEASES OVERVIEW OF THE CONVAL 10 SERVICE RELEASES CHANGES IN BUILD 10.4.2 Fixes of stability issues when exporting calculations Sound level corrections in downstream resistance structures were not taken into

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems

ABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems ABB MEASUREMENT & ANALYTICS DATA SHEET 9408 series Dissolved oxygen systems Measurement made easy Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling

More information

An approach to account ESP head degradation in gassy well for ESP frequency optimization

An approach to account ESP head degradation in gassy well for ESP frequency optimization SPE-171338-MS An approach to account ESP head degradation in gassy well for ESP frequency optimization V.A. Krasnov, Rosneft; K.V. Litvinenko, BashNIPIneft; R.A. Khabibullin, RSU of oil and gas Copyright

More information

Gas Measurement Fundamentals Certification. Curriculum

Gas Measurement Fundamentals Certification. Curriculum Gas Certification Institute, LLC P.O. Box 131525 Houston, Texas 77219-1525 281-598-7200 Phone 281-598-7199 Fax contact@gascertification.com www.gascertification.com Curriculum Copyright 2007-2012 Gas Certification

More information

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves

ISO INTERNATIONAL STANDARD. Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves INTERNATIONAL STANDARD ISO 21013-1 First edition 2008-06-15 Cryogenic vessels Pressure-relief accessories for cryogenic service Part 1: Reclosable pressure-relief valves Récipients cryogéniques Dispositifs

More information

Contribution to economic upstream gas metering with a dual-path ultrasonic metering solution

Contribution to economic upstream gas metering with a dual-path ultrasonic metering solution Contribution to economic upstream gas metering with a dual-path ultrasonic metering solution Sebastian Stoof, SICK AG, Germany Dr. Andreas Ehrlich, SICK AG, Germany Dr. Olaf Stawicki, SICK AG, Germany

More information

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods INTERNATIONAL STANDARD ISO 6570 First edition 2001-06-15 Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods Gaz naturel Détermination de la teneur en hydrocarbures liquides

More information

Accurate Measurement Guidelines

Accurate Measurement Guidelines Introduction This standard is designed to provide production operations personnel with detail information concerning Fieldwood's Measurement Standard Operating Procedures. Included are the following: Meter

More information

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD. No. 2000-03E Averaging Pitot Tube Flow Sensor HITROL CO., LTD. M e a s u r e m e n t Pr i n c i p l e Measurement principle of Hitbar sensor is explained below. When a Hitbar is installed in the pipeline

More information

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote Installation, Operation, & Maintenance Manual Mustang Sample Conditioning System MODEL: Watlow Controller P53 Direct, P53 Remote Conforms to UL STDS 61010-1 & 1203 Certified to CSA STD C22.2 Nos. 61010-1

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC

More information

Operational Settings:

Operational Settings: instrucalc features more than 70 routines associated with control valves, ISO flow elements, relief valves and rupture disks, and calculates process data at flow conditions for a comprehensive range of

More information

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter

More information

General Specifications

General Specifications General Specifications GS 34P02P32-01E Gas Flow Calculation Portfolio (FCN-500) GENERAL This general specification document describes the Gas Flow Calculation Portfolio for FCN-500 on FCN autonomous controllers.

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

Drilling Efficiency Utilizing Coriolis Flow Technology

Drilling Efficiency Utilizing Coriolis Flow Technology Session 12: Drilling Efficiency Utilizing Coriolis Flow Technology Clement Cabanayan Emerson Process Management Abstract Continuous, accurate and reliable measurement of drilling fluid volumes and densities

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating

More information

44 (0) E:

44 (0) E: FluidFlow Relief Valve Sizing Handbook Flite Software 2016 Flite Software N.I. Ltd, Block E, Balliniska Business Park, Springtown Rd, Derry, BT48 0LY, N. Ireland. T: 44 (0) 2871 279227 E: sales@fluidflowinfo.com

More information

UPM SONAR-based Wellhead Surveillance for Gas Condensate Fields Gabriel Dragnea, Expro Meters Inc., Siddesh Sridhar, Expro Meters Inc.

UPM SONAR-based Wellhead Surveillance for Gas Condensate Fields Gabriel Dragnea, Expro Meters Inc., Siddesh Sridhar, Expro Meters Inc. UPM 150 SONAR-based Wellhead Surveillance for Gas Condensate Fields Gabriel Dragnea, Expro Meters Inc., Siddesh Sridhar, Expro Meters Inc. Abstract Production optimization and reservoir management rely

More information

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility Jos G.M. van der Grinten, NMi EuroLoop Bart van der Stap, Flowways Dick van Driel, Krohne Abstract The operational experiences

More information

Listening to the flow

Listening to the flow Listening to the flow Measuring the flow of gas and liquids moving together through pipes is a notoriously difficult challenge. Malcolm Brown learns more about BP s initiative in developing a sonar-based

More information

SV60 Safety valves. for use with steam, gas and liquids

SV60 Safety valves. for use with steam, gas and liquids SV60 Safety valves for use with steam, gas and liquids Spirax Sarco safety valves - protecting people, plant and profit The SV60 spring loaded full lift safety valve range from Spirax Sarco has been designed

More information

2600T Series Pressure Transmitters Calibration Frequency Determination. Pressure Measurement Engineered solutions for all applications

2600T Series Pressure Transmitters Calibration Frequency Determination. Pressure Measurement Engineered solutions for all applications Application Description AG/266calib-EN Rev. B 2600T Series Pressure Transmitters Calibration Frequency Determination Pressure Measurement Engineered solutions for all applications Mantaining desired performances

More information

Endura AZ40 Sensor assembly Smart electronics PCB

Endura AZ40 Sensor assembly Smart electronics PCB Instruction replacement procedure INS/ANAINST/023 EN Endura AZ40 Sensor assembly Smart electronics PCB Kit reference: AZ400-769 Measurement made easy 1 Introduction This publication details replacement

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 6974-4 First edition 2000-04-01 Natural gas Determination of composition with defined uncertainty by gas chromatography Part 4: Determination of nitrogen, carbon dioxide and

More information

Micro Motion Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation

Micro Motion Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation Micro Motion Coriolis Oil & Gas Metering Recommended Practices for Upstream Allocation WWW.micromotion.com This document describes the best practices for selecting a Micro Motion flowmeter, which consists

More information

FAQs about Directive 017

FAQs about Directive 017 FAQs about Directive 017 General What measurement points are covered in this directive? The requirements in this directive cover all measurement points required by the Oil and Gas Conservation Regulations

More information

Diagnostics for Liquid Meters Do they only tell us what we already know? Terry Cousins - CEESI

Diagnostics for Liquid Meters Do they only tell us what we already know? Terry Cousins - CEESI Diagnostics for Liquid Meters Do they only tell us what we already know? Terry Cousins - CEESI DIAGNOSTICS FOR LIQUID METERS-DO THEY ONLY TELL US WHAT WE ALREADY KNOW? T. Cousins CEESI CMSI INTRODUCTION

More information

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications Contents Data Sheet S265 2600T Series Pressure Transmitters Engineered solutions for all applications Wide range of remote seal types Allows optimum design for each application without compromising performance

More information

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin New! ProFlow Sliding Vane Meters DN 15-5 (½ - 2 ) _ 142 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments ProFlow positive displacement sliding vane type liquid flowmeters are used in continuous

More information

Three Years of Experience of Wet Gas Allocation on Canyon Express

Three Years of Experience of Wet Gas Allocation on Canyon Express North Sea Flow Measurement Workshop 18 th - 21 st October 25 Three Years of Experience of Wet Gas Allocation on Canyon Express Aditya Singh, Total E&P USA James Hall, Letton-Hall Group Winsor Letton, Letton-Hall

More information

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible ABB MEASUREMENT & ANALYTICS TECHNICAL INFORMATION PositionMaster EDP300 Extended Diagnostics Compact, well-proven, and flexible The benefits of the extended diagnostics feature The PositionMaster EDP300

More information

Oil and Gas Custody Transfer

Oil and Gas Custody Transfer Downstream Focus By Emerie Dupuis Daniel Measurement and Control, Emerson Process Management Oil and Gas Custody Transfer When money changes hands, flow measurement accuracy matters. When flow measurement

More information

Part 6: Critical flow orifices

Part 6: Critical flow orifices Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 6145-6 Third edition 2017-07 Gas analysis Preparation of calibration gas mixtures using dynamic methods Part 6: Critical flow orifices Analyse

More information

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor INTERNATIONAL STANDARD ISO 15970 First edition 2008-06-15 Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor Gaz naturel Mesurage des caractéristiques

More information

New power in production logging

New power in production logging New power in production logging Locating the zones where fluids enter the wellbore in a producing or injecting well is an important aspect of production logging. It is relatively straightforward to establish

More information

IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS

IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS NYS AWWA Spring Conference Saratoga Springs, New York April 25, 2017 Robert Lucas, P.E. WHAT ARE WE TALKING ABOUT? Types of Flow Measuring Devices

More information

Pigging as a Flow Assurance Solution Avoiding Slug Catcher Overflow

Pigging as a Flow Assurance Solution Avoiding Slug Catcher Overflow Pigging as a Flow Assurance Solution Avoiding Slug Catcher Overflow Aidan O'Donoghue, Pipeline Research Limited, Glasgow, UK This paper sets out to provide an initial method of assessing the bypass requirements

More information

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4

STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK /J.02/0006-A4 Page 1 of 9 ` STANDARD SPECIFICATION FOR FLOW INSTRUMENTS DOCUMENT NO : 44-LK-5102-00/J.02/0006-A4 Rev No. Issue Date Pages Rev Description Prepared A 12.08.08 9 Issued for Comments / Approval By Checked

More information

SUBMERGED VENTURI FLUME. Tom Gill 1 Robert Einhellig 2 ABSTRACT

SUBMERGED VENTURI FLUME. Tom Gill 1 Robert Einhellig 2 ABSTRACT SUBMERGED VENTURI FLUME Tom Gill 1 Robert Einhellig 2 ABSTRACT Improvement in canal operating efficiency begins with establishing the ability to measure flow at key points in the delivery system. The lack

More information

ISO 4081 INTERNATIONAL STANDARD. Rubber hoses and tubing for cooling systems for internal-combustion engines Specification

ISO 4081 INTERNATIONAL STANDARD. Rubber hoses and tubing for cooling systems for internal-combustion engines Specification Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 4081 Third edition 2010-06-01 Rubber hoses and tubing for cooling systems for internal-combustion engines Specification Tubes et tuyaux en caoutchouc

More information

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES: SKYLINE FLOW CONTROLS INC. SFC Skyline Flow Controls Wedge Meter (SFC-WM) The SFC wedge meter is a differential pressure device for use on all fluids. It is especially designed for slurries and liquids

More information

2600T Series Pressure Transmitters Calibration Frequency Determination

2600T Series Pressure Transmitters Calibration Frequency Determination Application Description AG/266calib-EN Rev. A 2600T Series Pressure Transmitters Calibration Frequency Determination dl Pressure Measurement Engineered solutions for all applications Mantaining desired

More information

Calibrating and Monitoring MUSMs in Natural Gas Service

Calibrating and Monitoring MUSMs in Natural Gas Service Calibrating and Monitoring MUSMs in Natural Gas Service James E. Gallagher, P.E. Chief Executive Officer Copyright 2001 MUSMs in Natural Gas Service Slide 1 of 21 Abstract Companies today are grappling

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid

More information

Endura AZ40 Transmitter Main board spares kit

Endura AZ40 Transmitter Main board spares kit Instruction replacement procedure INS/ANAINST/018 EN Rev. A Endura AZ40 Transmitter Main board spares kit Kit reference: AZ400 767 Measurement made easy 1 Introduction This publication details replacement

More information

ATS430 turbidity sensor Retractable insertion assembly

ATS430 turbidity sensor Retractable insertion assembly A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion

More information

vj.i GUIDELINES --.- PETROLEUM (EXPLORATION & PRODUCTION) (MEASUREMENT) REGULATIONS, 2016 (L.I. 2246)

vj.i GUIDELINES --.- PETROLEUM (EXPLORATION & PRODUCTION) (MEASUREMENT) REGULATIONS, 2016 (L.I. 2246) vj.i --.- GUIDELINES TO PETROLEUM (EXPLORATION & PRODUCTION) (MEASUREMENT) REGULATIONS, 2016 (L.I. 2246) Published: February 2017 Petroleum Commission, Ghan GUIDELINES TO THE PETROLEUM (EXPLORATION AND

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 18213-2 First edition 2007-11-15 Nuclear fuel technology Tank calibration and volume determination for nuclear materials accountancy Part 2: Data standardization for tank calibration

More information

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC Flow measurement Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC WIKA data sheet FL 10.01 Applications Power generation Oil production and refining Water treatment

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 8655-4 First edition 2002-09-15 Piston-operated volumetric apparatus Part 4: Dilutors Appareils volumétriques à piston Partie 4: Diluteurs Reference number ISO 8655-4:2002(E)

More information