Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

Size: px
Start display at page:

Download "Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle"

Transcription

1 Cover Page for Lab Report Group Portion Compressible Flow in a Converging-Diverging Nozzle Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 13 January 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number: ME 325. Group letter: (A, B,...) Score (For instructor or TA use only): Lab experiment and results, plots, tables, etc. - Procedure portion Discussion Neatness & grammar TOTAL / 45 / 15 / 10 / 70 Comments (For instructor or TA use only):

2 Procedure and Presentations of Results Safety Precautions: Wear safety goggles at all times the air in the wind tunnel is pressurized. Leave the protective Plexiglas cover on the test section except when performing flow visualizations. Wear hearing protection if the sound level is bothersome. A hearing protector is available for each lab member. A. Getting familiar with the schlieren optical technique Before visualizing shock waves in the test section of the supersonic wind tunnel, familiarize yourself with the schlieren system by looking at some other simpler flow fields: 1. Turn on the LED light. Be careful not to bump any of the optics stands. 2. A schematic diagram of the schlieren setup is sketched In Figure 10. Verify that the schlieren imaging system is operating correctly. An image of the test section should be visible through the viewfinder of the camera. If the light passing through the test section is out of focus, adjust the manual focus ring on the camera lens. If the system falls out of alignment, get help from your instructor or TA. Figure 10. Schematic diagram of schlieren setup, view from the top. The key dimensions for this system are that the slit and knife-edge are located at the focal point of lens 1 and lens 2, respectively. These lenses are 70mm diameter with a 500mm focal length. The LED, condenser lens, and slit are all mounted together here. The knife edge is replaced by a color filter to convert from black-and-white schlieren imaging to color schlieren imaging. 3. With one group member holding the soldering iron inline with the test section, just inside the field of view of the schlieren system (do not touch the soldering iron tip to anything), the other group members can observe the image through the camera viewfinder. Turn on the soldering iron and see if you can observe a thermal plume. Take turns so that every group member gets to see the schlieren image. 4. Visualize other compressible flow phenomena, such as compressed air streaming out of a spray can, shop air exiting a nozzle (you should be able to see shock diamonds in the jet), the thermal plume from your hand, etc. B. Visualization of shock waves using the schlieren optical technique The following procedure should be used to start the flow facility. Use Figures 8 and 9 of the Introduction as a guide. 1. Ask your instructor or TA to check that the compressor is running. 2. Open back pressure Valve 3 (the large one) at least two turns, and open back pressure Valve 4 (the small one) at least two turns. 3. Open Valve 2 slowly until fully open. You should hear the rush of air through the system. Let the system run for several seconds the sound should reach a steady state level. The facility is now operating, and the flow rate is controllable by the two back pressure valves, Valves 3 and 4. Use Valve 3 for gross adjustment and Valve 4 for fine adjustment. Never close both back pressure valves completely; otherwise high pressure builds up in the test section, and the optical glass can shatter. Note: If at any time the pressure relief valve blows, or the test section glass shatters, shut off Valve 2 immediately, and call your instructor or TA. 4. Remove the Plexiglas protective cover from the test section. Everyone in the lab group should wear safety goggles. 5. Slowly adjust back pressure valves 3 and 4 and observe the flow patterns in the camera viewfinder. Are you able to observe a shock wave? At this point, ask your instructor or TA to point out a few details about the shock wave, an example of which is shown in Figure 11.

3 (a) (b) Figure 11. Color schlieren images in the compressible flow rig: (a) back pressure such that a shock wave is observed just downstream of the throat, and (b) lower back pressure such that the shock wave is much further downstream and Mach lines are observed in the isentropic flow region upstream of the shock structures. Note that no compressible-flow phenomena are observed upstream of the nozzle throat. (5) 6. Briefly describe below what happens to the shock wave as you increase and decrease the back pressure. Do your observations agree with the theoretical description of Figure 1 of the Introduction? (5) 7. On a separate page, sketch the observed flow pattern for two or three flow conditions, including one with no shock present and one with a shock present in the nozzle. You may also record the images with the camera. To operate the camera, begin by turning it on (it should be powered either by an internal battery or plugged into the wall). The camera should be set to manual operation (M), with the f-stop set to 1.8 and the shutter to Adjust the f-stop by rotating the dial near the shutter button on the lens-side of the camera. The shutter is adjusted by the dial on the view-screen-side of the camera. The shutter may need to be adjusted to record a properly illuminated image depending on the knife-edge position. Keep the f-stop full-open at 1.8. Remove the camera memory card and use one of the computers to save the images. For more detailed camera instructions, see the instruction manual or ask your TA for assistance. See Figures. C. Measurement of mass flow rate The test rig contains two flow rate measuring devices: a) a diaphragm meter and b) a Venturi meter. Only the diaphragm meter will be used in this lab experiment. This device directly measures the volume of gas passing through the meter. It works by rotating a vane inside, which is attached by gears to a counter and a revolving pointer. You may have seen similar meters for measuring the volume flow of water or natural gas in your home. A similar meter with a cut-away casing has been placed under the flow rig for your viewing pleasure. The accuracy of this type of flow meter is around a couple

4 percent, except when the volume flow rate falls below 5% of rated capacity. For our meter, one revolution of the pointer corresponds to 5 cubic feet of air, which is equivalent to a volume of m 3. To compute mass flow rate, use its definition, along with the ideal gas law, i.e. P V m Q (1) RT t where Q is the volume flow rate, measured as V t, where V is the volume of air passing through the meter in a measured time period t. Gas density is computed from the ideal gas law in Equation (7). Pressure P and temperature T must be measured just upstream of the flow meter. On the control panel, these correspond to the pressure toggle switch labeled Flow Meter Inlet, and thermocouple T 1 (number 1 on the dial). The control panel permits measurement of any of the pressure taps (see Figures 8 and 9 of the Introduction), with the pressure being read from the large Heise absolute pressure gauge. When measuring pressure, only one of the pressure toggle switches should be open at any time. The toggle switches merely connect the line from the chosen pressure tap directly into the input line for the Heise pressure gauge. Temperature is measured by thermocouples and a digital display unit. The temperature dial should be turned to the desired position to read the chosen temperature in degrees Centigrade. 1. Turn both Valve 3 and Valve 4 to their fully open (counterclockwise as far as possible) condition so that the imum flow rate is achieved through the system. Measure the pressure and temperature just upstream of the flow meter, as discussed above. Record (in the spaces provided below) these readings: P flow meter inlet = psia T flow meter inlet = T 1 = C (5) 2. With a stopwatch, measure the volume flow rate through the diaphragm meter, and calculate m using Equation (1). Show all your calculations in the space provided below. Show all units in your calculations, and be careful that the units combine correctly into kg/s. Note that 1 psia = N/m 2 = Pascals. m = kg/s (2) 3. For this same set of flow conditions (imum flow rate), measure both P 0 and P b. On the control panel, these are labeled P 2 and P 10 respectively. Again, note that only one pressure toggle switch should be open at a time; otherwise the pressure reading will be in error. Calculate the back pressure ratio for these conditions. Record your measurements in the spaces provided below: P 0 = P 2 = psia P b = p 10 = psia P b /P 0 =

5 (2) 4. The theoretical imum flow rate for air is given by * PA m o (2) 1/2 RT o In our experimental test rig, the stagnation temperature T 0 is equal to T 3 on the control panel, and throat area A * is equal to m 2. Calculate m for this same set of flow conditions. Show all your work (include units) in the space provided below: m = kg/s. (5) 5. Repeat Steps 1 through 4 above for several back pressures by turning Valves 3 and 4 slowly clockwise. Using the schlieren image as a guide, be sure to include cases ranging from fully supersonic throughout the entire diverging part of the nozzle (valves fully open) to fully subsonic everywhere (Valve 3 fully closed and Valve 4 nearly closed). Be sure to include several cases where a shock wave is present somewhere in the diverging part of the nozzle, and at least one case of fully subsonic flow (no shock). Also make sure that you include at least one case where the shock wave is just barely visible near the throat. For each case, measure P 0, P b, P flow meter inlet, T o, T flow meter inlet, and the volume flow rate using the flow meter and stopwatch as in Step 2 above. Also sketch the flow conditions in the converging-diverging nozzle for each case, pointing out the shock wave (if one exists). Calculate P b /P 0, m, m, and m / m for each case as well. Put all your results into a neatly labeled table. See Table. (5) 6. Plot m / m as a function of back pressure ratio P b /P 0. Compare your results with Figure 1c. Have you observed choking? Explain. See Figure.

6 D. Examination of choking and acoustic noise Two microphones are mounted in the test rig, one upstream and one downstream of the converging-diverging nozzle, as sketched in Figure 8 of the Introduction. Most of the flow-induced noise is generated downstream of the nozzle, where the flow is highly turbulent. When the flow is subsonic, sound can propagate upstream as well as downstream, and both microphones will pick up lots of noise. As discussed previously, however, when the flow becomes choked, noise can no longer propagate upstream past the throat. The upstream microphone should therefore suddenly be exposed to a much quieter flow whenever the nozzle chokes. (Ask your instructor or TA for help). (3) 1. Turn on the power supply (gray box) for the amplifier (black box), and turn up the volume on the amplifier. A toggle switch on the amplifier allows you to select either the upstream or downstream microphone. Vary the back pressure so that the flow goes from unchoked (subsonic everywhere) to choked. With the toggle switch pointed upstream (i.e. with the upstream microphone connected), describe your observations below. You may keep the schlieren system on to aid in your observations if you so desire. Does choking affect the sound recorded by the upstream microphone? Explain. (3) 2. Repeat the above with the downstream microphone. Does choking affect the sound recorded by the downstream microphone? At this point, ask the instructor or TA for assistance in the interpretation of your observations. E. Measurement of pressure distribution in the converging-diverging nozzle (5) 1. For several back pressure conditions (going the full range again from fully subsonic to fully supersonic), record pressures P 2 through P 10. Tabulate your results neatly in a table which should also include nondimensional pressure ratios P/P 0 for pressure tap locations 2 through 9, where again, P 0 is taken as pressure P 2. See Table. (5) 2. Plot P/P 0 as a function of streamwise coordinate x for all your cases in Step 1 above on the same plot. Include on your plot both the subsonic and supersonic theoretical calculations of P/P 0 from Table 1. If a shock wave is present, indicate its location on your plot. Note: The values of streamwise coordinate x can be obtained from Table 1. See Figure. 3. Shut off the flow in reverse order from the procedure to turn on the flow. Make sure the schlieren light bulb is turned off. Turn off the digital thermometer display unit. Make sure the Plexiglas safety cover has been reinstalled on the test section for protection.

7 Discussion (5) 1. Briefly summarize what you have learned about choking, and what it means. (5) 2. How well do your measurements of pressure agree with those of Figure 1 of the Introduction for the various back pressure ratios? Discuss possible reasons for any disagreement. (5) 3. When a shock wave is present in the diverging part of the nozzle, does the pressure jump up suddenly as indicated in Figure 1b of the Introduction? Why or why not?

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle

Cover Page for Lab Report Group Portion. Compressible Flow in a Converging-Diverging Nozzle Cover Page for Lab Report Group Portion Compressible Flow in a Converging-Diverging Nozzle Prepared by Professor J. M. Cimbala, Penn State University Latest revision: Prof. Steve Lynch, 14 February 2017

More information

A & AE 520 Background Information, Adapted from AAE334L, last revised 10-Feb-14 Page 1 1. SUPERSONIC WIND TUNNEL

A & AE 520 Background Information, Adapted from AAE334L, last revised 10-Feb-14 Page 1 1. SUPERSONIC WIND TUNNEL A & AE 50 Background Information, Adapted from AAE334L, last revised 10-Feb-14 Page 1 1.1 BACKGROUND 1. SUPERSONIC WIND TUNNEL 1.1.1 Objectives: This handout is adapted from the one once used in AAE334L

More information

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

Lab # 03: Visualization of Shock Waves by using Schlieren Technique AerE545 Lab # 03: Visualization of Shock Waves by using Schlieren Technique Objectives: 1. To get hands-on experiences about Schlieren technique for flow visualization. 2. To learn how to do the optics

More information

AE3610 Experiments in Fluid and Solid Mechanics OPTICAL/PRESSURE MEASUREMENTS IN SUPERSONIC FLOW

AE3610 Experiments in Fluid and Solid Mechanics OPTICAL/PRESSURE MEASUREMENTS IN SUPERSONIC FLOW AE3610 Experiments in Fluid and Solid Mechanics OPTICAL/PRESSURE MEASUREMENTS IN SUPERSONIC FLOW Objective This lab covers the use of taps, probes and transducers for measurement of static and stagnation

More information

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Cover Page for Lab Report Group Portion. Head Losses in Pipes Cover Page for Lab Report Group Portion Head Losses in Pipes Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 February 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section

More information

Cover Page for Lab Report Group Portion. Pump Performance

Cover Page for Lab Report Group Portion. Pump Performance Cover Page for Lab Report Group Portion Pump Performance Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:

More information

Cover Page for Lab Report Group Portion. Drag on Spheres

Cover Page for Lab Report Group Portion. Drag on Spheres Cover Page for Lab Report Group Portion Drag on Spheres Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 29 September 2017 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:

More information

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 16-1 A flow nozzle is to be used to determine the mass flow rate of air through a 1.5 inch internal diameter pipe. The air in the line upstream of the meters is at 70 F and 95 psig. The barometric pressure

More information

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Cover Page for Lab Report Group Portion. Boundary Layer Measurements Cover Page for Lab Report Group Portion Boundary Layer Measurements Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 30 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section

More information

Cover Page for Lab Report Group Portion. Flow Visualization in a Water Channel

Cover Page for Lab Report Group Portion. Flow Visualization in a Water Channel Cover Page for Lab Report Group Portion Flow Visualization in a Water Channel Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 08 September 2017 Name 1: Name 2: Name 3: [Name

More information

Flow in a shock tube

Flow in a shock tube Flow in a shock tube April 30, 05 Summary In the lab the shock Mach number as well as the Mach number downstream the moving shock are determined for different pressure ratios between the high and low pressure

More information

Cover Page for Lab Report Group Portion. Lift on a Wing

Cover Page for Lab Report Group Portion. Lift on a Wing Cover Page for Lab Report Group Portion Lift on a Wing Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 17 January 2017 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:

More information

Design of a Solid Wall Transonic Wind Tunnel

Design of a Solid Wall Transonic Wind Tunnel Design of a Solid Wall Transonic Wind Tunnel David Wall * Auburn University, Auburn, Alabama, 36849 A solid wall transonic wind tunnel was designed with optical access from three sides to allow for flow

More information

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

Lab 1c Isentropic Blow-down Process and Discharge Coefficient 058:080 Experimental Engineering Lab 1c Isentropic Blow-down Process and Discharge Coefficient OBJECTIVES - To study the transient discharge of a rigid pressurized tank; To determine the discharge coefficients

More information

Applied Fluid Mechanics

Applied Fluid Mechanics Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and

More information

256 Pneumatic Pressure Indicator

256 Pneumatic Pressure Indicator 256 Pneumatic Pressure Indicator 51425699 Copyright 2002 Slope Indicator Company. All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel. Any

More information

Model 130M Pneumatic Controller

Model 130M Pneumatic Controller Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate

More information

Manual for continuous distillation

Manual for continuous distillation Manual for continuous distillation 1. Week 1: Objectives: Run the column at total reflux. When steady state is reached, take the sample from the top and bottom of the column in order to determine the overall

More information

WIKA INSTRUMENT CORPORATION

WIKA INSTRUMENT CORPORATION WIKA INSTRUMENT CORPORATION Instruction Manual DIFFERENTIAL PRESSURE GAUGE Series 1500 Series 1000 Series 300 WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043 1-888-945-2872 http://www.wika.com

More information

Development of Gasdynamic Probe for Total Temperature Measurement in gases

Development of Gasdynamic Probe for Total Temperature Measurement in gases ASET 20- National Conference on Emerging Trends in Propulsion Technology Development of Gasdynamic Probe for Total Temperature Measurement in gases K Sathiyamoorthy, Souren Misra 2, Srinivas J, Baskaran

More information

Supersonic Flow and Shockwaves

Supersonic Flow and Shockwaves AER 304S Aerospace Laboratory II Supersonic Flow and Shockwaves http://sps.aerospace.utoronto.ca/labs/raal Experiment Duration: 150 min Instructor M. R. Emami Aerospace Undergraduate Laboratories University

More information

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION Aldin Justin 1, Robin James, Shruti Panicker 2,A.N.Subash,Saravana Kumar 1 Assistant Professor,Karunya University, aldinjustin@karunya.edu

More information

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope.

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope. HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope. The solar cell/solar panel shown above depict how a semiconductor can transform solar power into electrical power. Consider the solar panel

More information

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller CHEMICAL ENGINEERING LABORATORY CHEG 239W Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller Objective The experiment involves tuning a commercial process controller for temperature

More information

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12 LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/ This experiment will introduce you to the kinetic properties of low-pressure gases. You will make observations on the rates with which selected

More information

ME 333 Fluid Mechanics. Lab Session VISCOUS LOSSES IN PIPES

ME 333 Fluid Mechanics. Lab Session VISCOUS LOSSES IN PIPES ME 333 Fluid Mechanics Lab Session VISCOUS LOSSES IN PIPES Introduction Flow in pipes, laminar or turbulent, is subject to pressure losses that result from the viscous stresses on the wall of the pipe.

More information

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles International Journal of Engineering Research and Development e-issn: 7-067X, p-issn: 7-00X, www.ijerd.com Volume 3, Issue 4 (August ), PP. 33-39 Experimental Analysis on Vortex Tube Refrigerator Using

More information

User Manual for the Mars Calibration Bench

User Manual for the Mars Calibration Bench User Manual for the Mars Calibration Bench Fall 2013 Table of Contents Table of Contents Table of Contents... iii Introduction... v Chapter 1: The Mars Calibration Bench... 1 What Is the Mars Calibration

More information

Research and optimization of intake restrictor for Formula SAE car engine

Research and optimization of intake restrictor for Formula SAE car engine International Journal of Scientific and Research Publications, Volume 4, Issue 4, April 2014 1 Research and optimization of intake restrictor for Formula SAE car engine Pranav Anil Shinde Mechanical Engineering,

More information

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves Monday Morning Minutes by Norm Hall, August 20, 2018 The flow balance of a hydronic system is a critical component in the commissioning of

More information

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle RESEARCH ARTICLE OPEN ACCESS Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle Shyamshankar.M.B*, Sankar.V** *(Department of Aeronautical

More information

The University of Hong Kong Department of Physics Experimental Physics Laboratory

The University of Hong Kong Department of Physics Experimental Physics Laboratory The University of Hong Kong Department of Physics Experimental Physics Laboratory PHYS2260 Heat and Waves 2260-1 LABORATORY MANUAL Experiment 1: Adiabatic Gas Law Part A. Ideal Gas Law Equipment Required:

More information

MEGR-1627 Instruction Manual

MEGR-1627 Instruction Manual MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm

More information

Optimization of Ejector's Performance With a CFD Analysis. Amanda Mattos Karolline Ropelato Ricardo Medronho

Optimization of Ejector's Performance With a CFD Analysis. Amanda Mattos Karolline Ropelato Ricardo Medronho Optimization of Ejector's Performance With a CFD Analysis Amanda Mattos Karolline Ropelato Ricardo Medronho 2 Introduction Ejectors Equipment industrially used and based on the Venturi phenomena; With

More information

PREDICTION OF TOTAL PRESSURE CHARACTERISTICS IN THE SETTLING CHAMBER OF A SUPERSONIC BLOWDOWN WIND TUNNEL

PREDICTION OF TOTAL PRESSURE CHARACTERISTICS IN THE SETTLING CHAMBER OF A SUPERSONIC BLOWDOWN WIND TUNNEL PREDICTION OF TOTAL PRESSURE CHARACTERISTICS IN THE SETTLING CHAMBER OF A SUPERSONIC BLOWDOWN WIND TUNNEL S R Bhoi and G K Suryanarayana National Trisonic Aerodynamic Facilities, National Aerospace Laboratories,

More information

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow A model to examine pigging and inspection of gas networks with multiple pipelines, connections and

More information

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary ADH 1/7/014 LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary This experiment will introduce you to the kinetic properties of low-pressure gases. You will make observations on the

More information

1. Study the performance of a binary distillation column operated in batch mode.

1. Study the performance of a binary distillation column operated in batch mode. Goals for batch distillation using the East distillation column: 1. Study the performance of a binary distillation column operated in batch mode. 2. Determine the overall and local efficiency of the column

More information

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE

THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE THEORETICAL EVALUATION OF FLOW THROUGH CENTRIFUGAL COMPRESSOR STAGE S.Ramamurthy 1, R.Rajendran 1, R. S. Dileep Kumar 2 1 Scientist, Propulsion Division, National Aerospace Laboratories, Bangalore-560017,ramamurthy_srm@yahoo.com

More information

MANUAL BE SERIES Test Benches

MANUAL BE SERIES Test Benches The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES

More information

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through

More information

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH

****** * EX * ****** DWN W.W.POWELL CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA AND DISCHARGE HEADERS ASSOCIATED WITH BC ****** * EX * ****** DWN W.W.POWELL 4-17-75 CALCULATION OF FLOW LOSSES IN INLET CHK D.PAPA 4-17-75 AND DISCHARGE HEADERS ASSOCIATED WITH APPR APPR SAFETY RELIEF VALVES SIZE REV APPR A 02.0175.128 L

More information

Warnings: Notes: Revised: October 5, 2015

Warnings: Notes: Revised: October 5, 2015 Karl Suss MA6 Mask Aligner Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly on any campus

More information

Operating Instructions

Operating Instructions Operating Instructions Before operating the thin film evaporator, please be aware of all safety concerns associated with this experiment: Burn hazard from the column and steam lines, Chemical hazards associated

More information

4150K and 4160K Series Wizard II Pressure Controllers and Transmitters

4150K and 4160K Series Wizard II Pressure Controllers and Transmitters Instruction Manual Form 5177 March 1999 4150K and 4160K Series 4150K and 4160K Series Wizard II Pressure Controllers and Transmitters Contents Introduction.............................. 2 Scope of Manual.............................

More information

Observed in Gas Injection

Observed in Gas Injection Characteristics into Liquid* of Jetting Observed in Gas Injection By Yasuhisa OZAWA** and Kazum i MOR I * * Synopsis The present study is concerned with jetting behavior of gas jets injected into water

More information

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT S. No 1 Description Calorimeter The Unit should be designed for the accurate determination of the calorific value of liquid and solid hydrocarbons and other fuels. Specifications: A temperature-controlled

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Introductory Lab: Vacuum Methods

Introductory Lab: Vacuum Methods Introductory Lab: Vacuum Methods Experiments in Modern Physics (P451) In this lab you will become familiar with the various components of the lab vacuum system. There are many books on this topic one of

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop

More information

Experiment 1 Introduction to Some Laboratory Measurements

Experiment 1 Introduction to Some Laboratory Measurements Experiment 1 Introduction to Some Laboratory Measurements Introduction In this experiment you will familiarize yourself with the English & metric systems of measurement, weigh with a centigram balance,

More information

ABM MASK ALIGNERS. NanoFab 26 March 2009 A Micro Machining & Nanofabrication Facility

ABM MASK ALIGNERS. NanoFab 26 March 2009 A Micro Machining & Nanofabrication Facility ABM MASK ALIGNERS LOCATION: Optical Lithography PRIMARY TRAINER: Stephanie Bozic (2-6724, sbozic@ualberta.ca) SECONDARY TRAINER: Jolene Chorzempa (2-4823, jolenec@ualberta.ca) 1. OVERVIEW The ABM Mask

More information

Application Worksheet

Application Worksheet Application Worksheet All dimensions are nominal. Dimensions in [ ] are in millimeters. Service Conditions Medium Through Valve: Required C v : Temperature Maximum: Minimum: Normal: Flow Maximum: Minimum:

More information

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* THIS KIT CONTAINS: AOPS7741 (NATURAL TO PROPANE CONVERSION PARTS FOR MODEL SIZE, 50) AOPS7742(NATURAL

More information

Experiment 11: The Ideal Gas Law

Experiment 11: The Ideal Gas Law Experiment 11: The Ideal Gas Law The behavior of an ideal gas is described by its equation of state, PV = nrt. You will look at two special cases of this. Part 1: Determination of Absolute Zero. You will

More information

Lab 1. Adiabatic and reversible compression of a gas

Lab 1. Adiabatic and reversible compression of a gas Lab 1. Adiabatic and reversible compression of a gas Introduction The initial and final states of an adiabatic and reversible volume change of an ideal gas can be determined by the First Law of Thermodynamics

More information

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE Purpose of this Instrument: This instrument is for patterning photosensitive polymers with UV light. Location: White Hall 410 Cleanroom Primary

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2. STANDARD OPERATING PROCEDURES Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.5 ) Sampler (RAAS) AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION

More information

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring

More information

Write important assumptions used in derivation of Bernoulli s equation. Apart from an airplane wing, give an example based on Bernoulli s principle

Write important assumptions used in derivation of Bernoulli s equation. Apart from an airplane wing, give an example based on Bernoulli s principle HW#3 Sum07 #1. Answer in 4 to 5 lines in the space provided for each question: (a) A tank partially filled with water has a balloon well below the free surface and anchored to the bottom by a string. The

More information

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014 B Calibration of Split Hopkinson Pressure Bar Setup: Calibration is performed by comparing the wave speed of the initial pulse versus the reflected pulse and calculating the Energy Ratio. This ratio gives

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Portable Oil Lube Air Compressors

Portable Oil Lube Air Compressors Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be

More information

Dival 500 Pressure Regulators

Dival 500 Pressure Regulators Dival 500 Pressure Regulators Dival 500 Classification and Range of use The DIVAL 500 is a downstream direct-acting pressure regulator with balanced plug, for low, medium and high pressures. Suitable for

More information

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover

Device Description. Operating Information. CP Q (eq. 1) GT. Technical Bulletin TB-0607-CFP Hawkeye Industries Critical Flow Prover A compressible fluid traveling at subsonic velocity through a duct of constant cross section will increase velocity when passing through a region of reduced cross-sectional area (in this case, an orifice)

More information

Experiment 8: Minor Losses

Experiment 8: Minor Losses Experiment 8: Minor Losses Purpose: To determine the loss factors for flow through a range of pipe fittings including bends, a contraction, an enlargement and a gate-valve. Introduction: Energy losses

More information

Types 749B and R130 Changeover Manifolds

Types 749B and R130 Changeover Manifolds Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies

More information

-Fundamentals of Fluid Mechanics- Bruce Munson, Donald Young, Theodore Okiishi, Wade Huebsch

-Fundamentals of Fluid Mechanics- Bruce Munson, Donald Young, Theodore Okiishi, Wade Huebsch -Fundamentals of Fluid Mechanics- Bruce Munson, Donald Young, Theodore Okiishi, Wade Huebsch Fluids in the News (All Fluids in the News contained here are in the print edition as indicated) Table of Contents

More information

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1 www.apq.com.es EU Product / Spain DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1 Cod. RISUT5000A1 Cod. RISUT5000D1 DESCRIPTION The Suton 50001 Regulator is designed for use in distribution networks

More information

UNIVERSITY OF WATERLOO

UNIVERSITY OF WATERLOO UNIVERSITY OF WATERLOO Department of Chemical Engineering ChE 524 Process Control Laboratory Instruction Manual January, 2001 Revised: May, 2009 1 Experiment # 2 - Double Pipe Heat Exchanger Experimental

More information

Industrial Pneumatics

Industrial Pneumatics Industrial Pneumatics Industrial Training Manual 1 Level 1 Version 3.0 April 2015 This manual was developed for use with the following products: FluidSIM Pneumatics 5.0 English DEPCO Pneumatics Training

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code. This appendix is an excerpt from the 2003 International Fuel Gas Code, coordinated with

More information

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India) IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN(e) : 2278-1684, ISSN(p) : 2320 334X, PP : 45-49 www.iosrjournals.org Modeling, Optimization & Manufacturing of Vortex Tube and Application

More information

Lab. Manual. Fluid Mechanics. The Department of Civil and Architectural Engineering

Lab. Manual. Fluid Mechanics. The Department of Civil and Architectural Engineering Lab. Manual of Fluid Mechanics The Department of Civil and Architectural Engineering General Safety rules to be followed in Fluid Mechanics Lab: 1. Always wear shoes before entering lab. 2. Do not touch

More information

LAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY)

LAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY) LAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY) OPERATIONAL PROCEDURES Venue: Project Room, Hopkinson Lab, CUED Experimental date: 25 March 2008 Prepared by: Cheng Tung Chong (ctc31@camacuk)

More information

T208VR Series Tank Blanketing Vacuum Regulator

T208VR Series Tank Blanketing Vacuum Regulator February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease

More information

Lab 12 Standing Waves

Lab 12 Standing Waves b Lab 12 Standing Waves What You Need To Know: Types of Waves The study of waves is a major part of physics. There are quite a few types of waves that can be studied. Depending on who you have for lecture

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

Warnings: Notes: Revised: January 8,

Warnings: Notes: Revised: January 8, OAI Model 204IR Mask Aligner Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly on any campus

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is adopted as part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following factors must

More information

DS05C,D,G Dial Set Pressure Regulating Valves

DS05C,D,G Dial Set Pressure Regulating Valves DS05C,D,G Dial Set Pressure Regulating Valves APPLICATION The Honeywell DS05C,D,G Dial Set Pressure Regulating Valve is a high quality pressure regulating valve that maintains a constant outlet pressure

More information

Lab 12 Standing Waves

Lab 12 Standing Waves b Lab 12 Standing Waves What You Need To Know: Types of Waves The study of waves is a major part of physics. There are quite a few types of waves that can be studied. Depending on who you have for lecture

More information

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION Engineering MECHANICS, Vol. 20, 2013, No. 3/4, p. 213 220 213 AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION Václav Dvořák* The article deals with axial-symmetric subsonic air-to-air

More information

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003 CEE 331 Lab 1 Page 1 of 9 SAFETY Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003 Laboratory exercise based on an exercise developed by Dr. Monroe Weber-Shirk The major safety hazard in this

More information

ANALYSIS OF AERODYNAMIC CHARACTERISTICS OF A SUPERCRITICAL AIRFOIL FOR LOW SPEED AIRCRAFT

ANALYSIS OF AERODYNAMIC CHARACTERISTICS OF A SUPERCRITICAL AIRFOIL FOR LOW SPEED AIRCRAFT ANALYSIS OF AERODYNAMIC CHARACTERISTICS OF A SUPERCRITICAL AIRFOIL FOR LOW SPEED AIRCRAFT P.Sethunathan 1, M.Niventhran 2, V.Siva 2, R.Sadhan Kumar 2 1 Asst.Professor, Department of Aeronautical Engineering,

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Ideal gas law. Introduction

Ideal gas law. Introduction Ideal gas law Introduction We think of a gas as a collection of tiny particles in random, thermal motion. When they collide with the sides of a container, they exert a force on the container walls. The

More information

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation Certified Accuracy Ring Force Gauge The accurate measurement of mechanical forces is required in hundreds of applications from a simple weighing procedure to the calibration of testing machines and load

More information

ASHRAE made significant changes in 2001 to the calculations. Fundamentals of Safety Relief Systems

ASHRAE made significant changes in 2001 to the calculations. Fundamentals of Safety Relief Systems 2008, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Journal, Vol. 50, February 2008. This posting is by permission of ASHRAE. Additional

More information

Approved by Principal Investigator Date: Approved by Super User: Date:

Approved by Principal Investigator Date: Approved by Super User: Date: Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC OAI 200 Lithographic Mask Aligner (Aligner 3) Version 2011 June 2 I. Purpose This Standard Operating

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

Methods of Rating Flow

Methods of Rating Flow Methods of Rating Flow What engineers need to know when using CV as a measurement of flow in pneumatic applications In the pneumatic industry, CV is one standard for expressing the flow capacity of devices

More information

Pressure Reducing Valve for Steam Type 2333 A

Pressure Reducing Valve for Steam Type 2333 A Pressure Reducing Valve for Steam Type 2333 A Fig. 1 Type 2333 A 1. Design and principle of operation The pressure reducing valve consists of a balanced control valve and a closing actuator equipped with

More information

installation instructions

installation instructions installation instructions GAS CONVERSION KIT PROPANE-TO-NATURAL P/N 315572-71201 4GAD 6GAD Cancels: IIK 4G-50-4 IIK 4G-50-5 7/15/91 NOTE: Read the entire instructions before starting the installation.

More information

4: PROPERTIES OF WAVES Definition of Wave: A wave is a disturbance traveling in a medium.

4: PROPERTIES OF WAVES Definition of Wave: A wave is a disturbance traveling in a medium. 4: PROPERTIES OF WAVES Definition of Wave: A wave is a disturbance traveling in a medium. A. SMALL GROUP ACTIVITIES WITH SLINKIES Several basic properties of wave behavior can be demonstrated with long

More information