1 S MFD/LRL Generators Page 1 Ground Current Generator GCG By Tim Williams Owners Manual Release Date: Thursday, December 29, 2011 This document is subjected to change without any notice. Please check the release date. IMPORTANT NOTICE No parts of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, mechanical, electric, photocopying, recording or otherwise without written permission of Tim Williams. Copyright, All rights reserved. By Tim Williams

2 Description: S MFD/LRL Generators Page 2 The GCG unit is a 2 probe system, but different than other 2 probes systems on the market today. There are two modes of operation for the GCG. One is normal and the other scaled. The GCG injects voltage into the ground and the voltage drop value is logged on the logger. The unit can also be used alone with a digital voltmeter and log the values manually. Normal Mode: This mode is used when searching for large changes in ground anomalies like caves. Scaled Mode: This is the mode that makes the GCG stand out from other 2 probe systems! Here's how it works. The GCG takes a sample of the average ground value determine by a number of probe samples in the area. Once you are sure the data values are constant, during a sample in Normal mode the mode switch is switched to scaled. The unit now knows the background value and all readings sampled will show above and below that value! This increases the resolution of the standard 2-probe system! The GCG has a micro-controller that handles all the data. The unit is designed to be used with the logger, but can be used with a meter also. There is an output that connects to the logger via the cable that comes with the logger. The unit also has the standard 4-probe 6- sample selection switch if you are used to using that method. The method for this unit with the logger is placing your probe in the ground at selected points in the grid with one probe back out from the center of the grid about 30 feet. You move the probes the same way you do when you log using a metal detector! If you want to use the unit alone you can by connecting a digital voltmeter with a cable supplied with the GCG unit. Mark each value down and the position and later place in software to view the plot! Note: Ground resistivity is a relative measurement and changes from site to site and ground conditions. I would suggest that you read up on ground resistivity and why it works to understand what you are looking at with the plots from the GCG unit. I will try to help you understand how to use the GCG unit properly. Methods of Use: The first method is the method you will be using the most, the X, Y method. The setup is as follows. Grid the area you want to log using some ropes marked every 3 feet. You will end up with the similar to the grid shown below. You will use probes 1 & 2 and place the switch in that position. It s just like using a metal detector, except you move the probe to each square and take a sample.

3 S MFD/LRL Generators Page 3 Fig 1. Logger Setup: Set the Arc-Geo grid size as shown in the Arc-Geo manual and place the Log Mode switch to Manual. The Sense should always be at 100% if you have an older model. Connect the cable from the GCG to the logger. Setup the logger for the grid size you want. You should see the L for log mode and the X, Y first position 1,1. That is the first position you would place the probe to start your grid in the upper left corner. Make sure the mode is set to manual. GCG Scaled Mode: Place the MODE switch in the manual mode. Place the remote probe out 30 feet from the grid. The probe should be 30 foot apart. Press and hold the test button and note the data on the logger. Set the +/- button on the logger so that when you adjust the threshold on the GCG down the data goes down. Take the 4 to 6 readings in different positions about 12 foot apart. You want to take a number of readings to see the average background reading of the ground in the area you are plotting. Press the button and note the reading on the logger. You want to note the value of each. What you are looking for is a little change between readings. For example: if you have the following 5 readings. 330, 335, 325, 338, 340 these values are not changing a great deal and can be used to set the GCG in Scaled mode. But if you are seeing 330, 390, 425, 500, 300, then you may be over an object. You would have to move to another area and repeat. Each time you take a reading move both probes about 4 feet and take another reading. Press and hold test and adjust the threshold so that the data is around 50 or so on the logger. To set the scaled mode press and hold the sample button, change the Mode switch to Scaled and release the test button. The GCG has sampled the ground and set the reference and is now ready to log in scaled mode.

4 S MFD/LRL Generators Page 4 NOTE: DO NOT CHANGE THE THRESHOLD OR THE MODE SWITCH DURING THE PLOT. If you change the mode switch back to Normal you have to resample and select Scaled. Once Scaled is set you can do multiple grids in that area. Set Threshold: With the remote probe out 30 feet and the sample probe in the first position on the grid, press the test button and adjust the threshold for around 50. Threshold is used to set a background value above 0. The threshold should be set before starting each grid. Probe Placement: Place a probe out 30 feet from the center of the plot you have setup to log. With the other probe place it in the first location X1, Y1 in the grid area. Y = the row in the grid and X = the column in the grid area. Now each time you place the probe in the ground you need to press the test button and watch the logger for the data to settle so that the number stops changing but maybe +-1 or 2 digits. While holding the test button, press the log button on the logger and log the value then release the test button. Move the probe to the next position and repeat. Do this for until the grid is complete. Download and view the plot.

5 S MFD/LRL Generators Page 5 Here you can see the grid setup using ropes marked every 3 feet. This is a 4 x 16-yard plot. Notice that the tank is to one side of the plot. You will see this at the end of this manual. The first position on the grid.

6 S MFD/LRL Generators Page 6 Move the probe in the direction on the grid at each mark till the grid is complete. See fig 1. Normal Mode: You can log in normal mode, but Scaled is better for smaller ground anomalies. If you are looking for a cave or large vault you can use normal mode. Both modes will show ground anomalies. Depth: For a 2-probe system the depth is about half the distance of the probes. So if you have the probes 50 feet apart you should be close to reaching 25 feet in the ground. To find the depth of an object, the object first has to be located and centered.

7 S MFD/LRL Generators Page 7 Notes: Make sure you are not touching the probe when the Test button is pressed! High voltage is on the probes 110vac! DO NOT PRESS THE TEST BUTTON WHEN SOMEONE IS HOLDING OR TOUCHING THE PROBE! Try to place the probe in line on the grid locations. The better your lines and marks, the better your plots will be. If you are logging in the scaled mode and the data sample goes way off from 134 to 800 then you are over a high resistance area. Or if you see 675 and the data changes to 200, you are over a low resistance area. Any large change should be checked out by doing an X, Y plot over that area. If the values change from high to low more than 100 then switch to Normal and grid the area. It would be faster for 2 people to work with the probes. One person to move the probe to each location and one person to log the data and telling the other person when to move the probe. The tank shown using the GCG and Arc-Geo Logger. The reds and greens are high resistivity and the blues are lower resistivity. Water has collected around the tank area. At the back of the tank (far left) is the lowest reading in purple.

8 S MFD/LRL Generators Page 8 Remember the condition of the object you are looking for will show in the plot. If you are plotting an area for old graves, some may be high resistance colors while other may be low. This is due to the amount of water that may be in the container. You have to know how to read a plot. The important thing to remember is, if the object/pattern is man made or natural? The color bar shows you the high to low colors and from the data values. Box Square Method: I will touch on this method a little. I included the 6-sample on my unit because some units have it and some are used to using that method. The X, Y method I fell will give you far better results. Here is what you are looking for in a nutshell, changes in data from one set of probes to the others. Remember low values are low resistance objects like water, metals or conductive materials. High values are high resistance objects like rocks, sand, and different levels of less moisture content in the ground. The square can be any size depending on the depth you are trying to reach. If you were looking for a target 5 feet deep, you would place the probes about 10 foot apart. If one set of probe reading is lower than the others and the cross readings, you should move the square over and center the square over the lowest reading. If the square is centered over the target the lowest reading should not be between the cross sections of the square setup. To find the depth you would increase or decrease the square and note the data changes.

9 S MFD/LRL Generators Page 9 Straight Line Method: I choose to use this method over the box method. Sense I know the location of the anomaly whether it is low or high readings, I can tell the depth by the method below. Starting over the X, Y position of the anomaly, I would place probes (1 & 2) 4 feet apart and log the data. Next move both probes out 4 feet out in a straight line and log a reading. Repeat this for the maximum depth you would expect the target to be or greater and log each value in the logger. You would setup a Depth grid in the logger for a depth plot. A depth plot is Y (the number of reading probe movements) and X as 1. So the first square when viewing the plot would be 4, next 8, 16 and so on. Remember the depth is half the distance of the probes. Diagram of depth plot. 1.5 = = = = =69 Here is the plot you would see in ArcheoSuveyor-LT. You do not use graduated shade to view the depth plot. This is a depth plot of the tank. The probes were moved 3 feet out for each reading. So the probe distance for each reading would be; 3 ft, 9ft, 15ft, 21ft and

10 S MFD/LRL Generators Page 10 27ft. You can see from the data and color change where the top of the tank is and the bottom! The top of the tank is about 1 foot from the surface. So for a depth of 1.5ft the data was 132. The body of the tank (center) is at 4.5ft and a reading of 138. In the 7.5ft reading you can see the data reading is starting to drop again at 133. Now you can see at 10.5ft the data is 76 and the signal is passing under the tank! Still deeper at 13.5 ft the data drops more to 69. So by looking at the depth plot you can see the top of the tank is close to the surface and the bottom of the tank is about 7.5 ft deep in the ground. This could be a vault. By doing a depth plot you can view the plot and see the depth to the object and the bottom of the object at one glance. Depth plots can be as many samples in depth as you want to go. You only need to remember the distance you move each probe as you increase the space keeping the object in the center of the plot. So if you 3 foot spacing, move both probes the same amount 3ft, the distance would be 9ft. Then another 3ft the distance would be 15ft, 21ft, 27ft and so on. Of course the depth would be half of each measurement distance. 3ft=1.5ft deep 9ft=4.5ft deep 15ft=7.5ft deep 21ft=10.5ft deep 27ft=13.5ft deep You can see the depth at a glance once you see the color bar of the depth plot and know the distance of each sample. Using a Jig:

11 S MFD/LRL Generators Page 11 Test Jig This is a 3-foot test jig for locating anomalies to a depth of about 1ft to 3.5ft. The sample is taken between the tow probes mounted on the PVC pipes. The logger is setup the same way for an X, Y grid and you walk with the unit sampling at each location. This is a good method for seeing foundations and old roads and even graves. The two plots below were done using this jig with the GCG and logger.

12 S MFD/LRL Generators Page 12 Scaled Mode. Normal Mode. Specifications: Small compact design, easy to carry. 6V 4.5ah Lead Acid Rechargeable Battery, charge LED. Normal Mode used for large anomalies. Scaled Mode, used for smaller anomalies, better detail. Low Battery LED indicator. 6-Posistion Sample Switch Box Method. Log directly to Arc-Geo Logger. Output for viewing and logging on DC Volt meter Manual Log. Voltage output 20ma Charging: Charge the GCG for 12 hours (overnight). Do not over charge the battery! If you over charge the battery and it harms the PCB by leaking acid, it is not covered under warranty. Testing the unit:

13 S MFD/LRL Generators Page 13 I would suggest that you find an old tank or something-large underground to test on. Test and test until you get an idea for comparing the plot to the object you tested on. You have to think if the object is an insulator or a conductor. If you have some culverts near you try to fine one made of iron lower resistance and one made of cement higher resistance. Do plots over both and also do depth plots and you will see the difference. You cannot use an instrument unless you know how and why it works. Water is a good conductor. Metal is also a conductor. But at the same time a cement vault is a high conductor! You can see it is not an easy way. This unit will show you high and low anomalies in the ground. I don t know if any equipment that will produce a treasure for you! Test until you know what you are looking at. This unit is a very important part of your treasure hunting equipment. Probes: You can make your own probes if you want. Simple probes to make are an 18 piece of copper-coated grounding rod and sharpen one end. You can connect to them using a clamp. Or you can make a rod with the top bent into a handle. Here are some pictures of the rods I am offering on my site. The pictures are as follows; 18 T-Rod, 48 T-rod with footrest, Wire Connection, Hammer spot on T-rod. These Probes are made with 401 Stainless Steel 3/8 rod and 5/8 SS handles. Check my site for current price and availability.

14 S MFD/LRL Generators Page 14 Clamp Used to connect to rod. I like to use a fork connection instead of a clamp shown above. NOTE: Make sure the probe contact is the same for each sample. The probe should be the same depth each time. The depth of the probe will be different for the ground conditions. A minimum of 12 deep is good for average ground conditions. Closing Notes: You can get added information on a site using ground resistivity. You should know that values change with ground conditions. From sand to rocks and clays all have different background values. Some instruments have lamps and fixed resistivity values for metals like gold and silver. I have to say that it does not work that way. Down here near the coast and at sea level the normal resistance is around 150 to 200 ohms! The lamp would stay on all the time. Does that mean I have metal in the ground everywhere I use it? No! Every area is different. You have to sample the background normal ground resistance for that area and look for changes from that value high or low. An iron strongbox 2x2 feet at 4 feet may only change the value ohms in a dry area. The amount of change depends on the size of the target and ground conditions in that area. The same strong box may show a change of 100 from normal because water may be collected around it. Or if you live where I do you may never see that box because it may be sitting in the water table! Resistance is relative to the area you are searching! Get information of the depth of the water table and other information of the site you intend to search. I m using example values of change. A change of 2 10 is still a change. I hope you enjoy the GCG unit. It can be a valuable tool in the field and give added information on a site. Along with the Arc-Geo logger you have the tools you need to see in the ground and determine if you want to dig or not. No matter what equipment you use, the decision to dig will be up to you. I am being straight up here. No one wants to waste time digging. The more information you have the better. I will have more on the CGC unit soon and update the manual as needed.

15 S MFD/LRL Generators Page 15 WARNING! Be careful when handling the probes. When the test button is pressed, around 20ma maximum is present on the probe. NEVER press the test button when a person is holding or touching the probe. All ground resistivity units can shock you with high voltage. Some have higher voltage than the GCG unit. Always be careful. By using this equipment you understand the dangers involved and with any ground resistivity system, that it is dangerous and you do not hold me responsible for your actions and use of this equipment. Best wishes to you and good hunting! Regards, Tim Williams

STARLOG. Capacitive Water Depth Probe

STARLOG. Capacitive Water Depth Probe STARLOG Capacitive Water Depth Probe Model 6521 User Manual Supplement 6219 Revision D July 10. 1998 Copyright Notice Copyright Unidata Australia 1998. All rights reserved. No part of this publication

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

Low Wind High Yields Series

Low Wind High Yields Series Low Wind High Yields Series Wind Turbines USER S MANUAL Introduction Low Wind High Yields Series rotor blades apply the latest advanced thermoplastic engineering and are manufactured by precision injection

More information

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination Warning: Non-vented water level loggers may have readings with errors of up to 250mm due to barometric pressure changes.

More information

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension

More information

Prewired position switches FA series

Prewired position switches FA series Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:

More information

Constant Pressure Inlet (CCN) Operator Manual

Constant Pressure Inlet (CCN) Operator Manual Constant Pressure Inlet (CCN) Operator Manual DOC-0125 Revision J 2545 Central Avenue Boulder, CO 80301-5727 USA C O P Y R I G H T 2 0 1 1 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I

More information

Ultrasonic Fuel Level Sensor - UFLS

Ultrasonic Fuel Level Sensor - UFLS Ultrasonic Fuel Level Sensor If your business infrastructure relies on backup generators, the chances are you are also relying on fuel to power those. By using the AKCP Ultrasonic Fuel Level Sensor you

More information

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK 1) Unpack all of the equipment and immediately inspect for shipping damage. Damages should be immediately reported to the carrier and noted on the

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

ES18 Security Theory/Regulations Answer Schedule

ES18 Security Theory/Regulations Answer Schedule ES18 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker

More information

DTG - LCD Digital Temperature Gauge USER MANUAL

DTG - LCD Digital Temperature Gauge USER MANUAL DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.

More information

OC Panel High Limit Aquastat Kit, Manual Reset p/n

OC Panel High Limit Aquastat Kit, Manual Reset p/n OC Panel High Limit Aquastat Kit, Manual Reset p/n 233202 Instruction Sheet APPLICATION The OC (Option Control) Panel High Limit Aquastat Kit provides electronic temperature sensing in a UL limit-rated

More information

BUYER S GUIDE AQUAlogger 530WTD

BUYER S GUIDE AQUAlogger 530WTD OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii Operator s Manual Table of Contents Operator Safety... 1 Introduction... 2 Unpacking and Setup... 3 Unpacking... 3 Setup... 4 FLYER Overview... 5 FLYER Diagram... 5 Capabilities... 5 Control Panel... 6

More information

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000 5 Function Indicator +20 +40-5000 STD TEMP SL 15000 Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage 427 HILLCREST WAY REDWOOD CITY, CA 94062

More information

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) Miniature size in-line Thermocouple Socket with stainless

More information

HEATEC TEC-NOTE Publication No Revised

HEATEC TEC-NOTE Publication No Revised HEATEC TEC-NOTE Revised 6-17-10 Setting up Vega radar sensors for Heatec vertical asphalt tanks This document provides information for setting up Vega radar sensors installed on Heatec tanks that store

More information

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Rev.02 (2014.06) OL Page 1 of 8 Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 INTRODUCTION... 5 1.1 Use

More information

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983 Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

T EK-SUB 4800C 19 mm Submersible Level Transmitter

T EK-SUB 4800C 19 mm Submersible Level Transmitter Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2

More information

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Cambridge International Examinations Cambridge International General Certificate of Secondary Education Cambridge International Examinations Cambridge International General Certificate of Secondary Education *8269683414* PHYSICS 0625/31 Paper 3 Extended October/November 2014 1 hour 15 minutes Candidates

More information

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408) RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com

More information

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM MODEL 269DF-LCF-LCF/WS FILLING SYSTEM 29975 Parkway Roseville, Michigan 48066 (586) 778-0426 Fax (586) 778-0479 www.gordinier.com Email: pat@gordinier.com MODEL 269DF-LCF-LCF/WS TABLE OF CONTENTS Receiving

More information

Smart performance with innovative and ever-strong coil drive even under harsh working environments

Smart performance with innovative and ever-strong coil drive even under harsh working environments Smart Valve Positioner SS2 inear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)

More information

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017 HS Bubbler Technology HyQuest Solutions New Zealand User Group August 2017 Origins of Gas Purge Technology 1940 s - Developed By Dutch Engineer Late 1940 s 1954 - Adopted by State of Illinois Water Group

More information

Product Cross Reference Charts

Product Cross Reference Charts Product Cross Reference Charts AC Clamp Meters Easy Viewing With the patented design of our new Swivel Clamp Meters, you can see the reading even in tight or inconvenient spots. Simply rotate the head

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 100-1950 WEATHER STATION INSTRUCTION MANUAL Receiving and Unpacking Carefully unpack all components and compare to packing list. Notify NovaLynx Corporation immediately concerning

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

Polatrak ROV II - Tip Contact Probe Operation Manual

Polatrak ROV II - Tip Contact Probe Operation Manual This PDF document contains Live Web Links Click them for more information from the web Polatrak ROV II - Tip Contact Probe Operation Manual A Cathodic Protection Probe with dual Ag/AgCl reference cells

More information

660 Multipoint Electronic Level Switch

660 Multipoint Electronic Level Switch 660 Multipoint Electronic Level Switch General Instructions The Multipoint Electronic Level Switch is a level sensing device which reads process level by capacitance measurement. Capacitance varies according

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Gas Pressure Probe. Information Sheet. Total Dissolved Gas Total Dissolved Gas Information Sheet T900 Total Dissolved Gas Pressure Probe Description The In-Situ Inc. T900 probe is a specially adapted submersible pressure transducer designed to monitor Total Dissolved

More information

Precision Liquid Settlement Array Manual

Precision Liquid Settlement Array Manual Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

Baseline Two-Wire Technology

Baseline Two-Wire Technology Baseline Two-Wire Technology Baseline s bicoders work with Baseline s biline two-wire technology to create the only true bi-direc onal two-wire devices in the industry. Baseline s bicoders not only receive

More information

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. . User Manual Capacitance Continuous Level Indicator Comprehensive User s Manual. Introduction. General Description. Principle of Operation. Specifications. Connection Diagrams. Quick Calibration Chart.

More information

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission

More information

NEULOG OXYGEN LOGGER SENSOR GUIDE

NEULOG OXYGEN LOGGER SENSOR GUIDE NeuLog oxygen logger sensor NUL-205 The oxygen sensor can be used for any science experiment or activity where oxygen levels, dissolved or gaseous, are required. Some fields of study include Chemistry,

More information

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development. Inoxair Repair Manual Edition: 12/2010 Content 1) Serial number 2) Technical data 3) Functional principle 4) Problem analysis 5) Removal 6) Repairs 7) Circuit diagram and cable-connection-plan 8) Pneumatic

More information

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin Electronic Control Manual 216 Sensors and Stats Section S Technical Bulletin CDS-2000 Issue Date 0393 CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin Introduction 3 Pre-Verification

More information

Electronic gas volume corrector model DGVC-04

Electronic gas volume corrector model DGVC-04 Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector

More information

BUYER S GUIDE AQUAlogger 520

BUYER S GUIDE AQUAlogger 520 OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 520 Mini Temperature and Pressure Logger AQUAlogger 520 Aquatec s primary temperature and depth model, the AQUAlogger 520, combines years of product development

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

KING-GAGE. Calibration Instruction Manual. D/P LiquiSeal Purge Control and D/P Purge Control

KING-GAGE. Calibration Instruction Manual. D/P LiquiSeal Purge Control and D/P Purge Control Effective: June 2010 KING-GAGE D/P LiquiSeal Purge Control and D/P Purge Control Calibration Instruction Manual for models 738 D/P LiquiSeal Purge Control and 788 D/P Purge Control D/P LiquiSeal Purge

More information

metal detector 98760

metal detector 98760 metal detector 98760 Set up and Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com Read

More information

Evaluation of Ground Ring vs. Equipotential Mat at a Swimming Pool in Buford, Georgia

Evaluation of Ground Ring vs. Equipotential Mat at a Swimming Pool in Buford, Georgia Evaluation of Ground Ring vs. Equipotential Mat at a Swimming Pool in Buford, Georgia NEETRAC Project -132 August, 2 A Research Center of the Georgia Institute of Technology Requested by: Reuben Clark

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION

More information

Installation, use and maintenance instructions. Gas burner (5)

Installation, use and maintenance instructions. Gas burner (5) Installation, use and maintenance instructions Gas burner MODEL GAS 4 TYPE 516 T80 291 (5) TECHNICAL FEATURES Thermal output 180-470 kw 154.800-404.200 kcal/h Fuel Natural gas Pci 8-10 kwh/m 3 = 7000-8600

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720. If

More information

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler. Exercise 5-2 Bubblers EXERCISE OBJECTIVE Learn to measure the level in a vessel using a bubbler. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Bubblers How to measure

More information

Pulsed Eddy Current (PEC) Inspection through Insulation

Pulsed Eddy Current (PEC) Inspection through Insulation Pulsed Eddy Current (PEC) Inspection through Insulation Inspection through insulation opens unexpected opportunities Shell Global Solutions in Amsterdam has developed over the past few years an inspection

More information

GV Standard X-Vent. Setup, Commissioning & Installation Guide

GV Standard X-Vent. Setup, Commissioning & Installation Guide GV Standard X-Vent Setup, Commissioning & Installation Guide Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

More information

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT MODEL 863-000-200 DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT DOCUMENT NO. 430-017C April 14, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875

More information

7 Common Cattle Fencing Mistakes. Seven of the most common errors in livestock fencing, and how to avoid them.

7 Common Cattle Fencing Mistakes. Seven of the most common errors in livestock fencing, and how to avoid them. 7 Common Cattle Fencing Mistakes Seven of the most common errors in livestock fencing, and how to avoid them. 7 COMMON CATTLE FENCING MISTAKES 1 Whether you re an experienced hand or just learning the

More information

ATOC Meteorological Tower (6 meter-4 level) Guide

ATOC Meteorological Tower (6 meter-4 level) Guide ATOC Meteorological Tower (6 meter-4 level) Guide SETUP Outline 1. Siting 2. Components 3. Transportation 4. The Tower 5. The Cables and Data Logger Siting Selecting an appropriate site for the weather

More information

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982

Product information. Capacitive. Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67. Document ID: 29982 Product information Level detection with bulk solids VEGACAP 62 VEGACAP 65 VEGACAP 66 VEGACAP 67 Document ID: 29982 Contents Contents 1 Description of the measuring principle... 3 2 Type overview... 5

More information

Figure Source:

Figure Source: In the Fall of 2018, EPRI opened a test facility to the public so that they could witness testing at the EPRI swimming pool assessment infrastructure within EPRI s laboratory in Lenox, Massachusetts. Those

More information

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist INDEX Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR COMPRESSED AIR SAVING PRODUCTS Condensate Management Specialist Information provided herewith is believed to be accurate and reliable. However,

More information

Electric and Natural Gas Safety Trainer s Guide

Electric and Natural Gas Safety Trainer s Guide Worker Safety Electric and Natural Gas Safety Trainer s Guide Contents INTRODUCTION... 2 SECTION ONE: KNOW YOUR AUDIENCE... 2 SECTION TWO: UTILITY BASICS... 2 What Is Electricity?... 2 The Electricity

More information

These Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National

These Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National These Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National Grid, on or near to its electricity apparatus. National

More information

MODEL GT820 OXYGEN SENSOR

MODEL GT820 OXYGEN SENSOR INSTRUCTION MANUAL MODEL GT820 OXYGEN SENSOR 70046 The information and technical data disclosed by this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure switch / Lube oil protection control MP 54 and MP 55 Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors

More information

Flow Sensors & Hydrometers Specification Sheet

Flow Sensors & Hydrometers Specification Sheet Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,

More information

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring

More information

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration 4 Digit Display, 4-20mA Output Instruction Manual (Digital Differential Pressure Transmitter) 1. General Specification 2. Installation 3. Wiring 4. Function 5. Setting & Calibration 1 4 20 1 Differential

More information

A Beginner s Guide to Portable Electric Fencing A summary of an interview with Stephanie Sexton, Product Manager at Premier 1 Supplies

A Beginner s Guide to Portable Electric Fencing A summary of an interview with Stephanie Sexton, Product Manager at Premier 1 Supplies A Beginner s Guide to Portable Electric Fencing A summary of an interview with Stephanie Sexton, Product Manager at Premier 1 Supplies By Diego Footer - Co-Host of Grass Fed Life May 2017 How does electric

More information

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

TEK-SUB 4800B. Submersible Level Transmitter.   Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter

More information

PURA. Pure Gas Dewpoint Transmitter. Users Guide

PURA. Pure Gas Dewpoint Transmitter. Users Guide PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter

More information

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation. Quality Products at Competitive Prices Gas Check Automatic testing of the down-stream installation to check that all valves are closed and that pipework and fittings are gas tight before each system start-up.

More information

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

TEK-THERMAL 1700B. Thermal Mass Flowmeter.   FLOW. Technology Solutions Technology Solutions TEK-THERMAL 1700B Thermal Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Thermal 1700B Thermal Mass Flowmeters,

More information

GasLab SAN-102 Micro Oxygen Monitor User Manual

GasLab SAN-102 Micro Oxygen Monitor User Manual GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined

More information

Plankton pump Model ,2 KWatt. Manual. KC Denmark. Research Equipment Limnology Oceanography Hydrobiology

Plankton pump Model ,2 KWatt. Manual. KC Denmark. Research Equipment Limnology Oceanography Hydrobiology Plankton pump Model 23.580 2,2 KWatt Manual KC Denmark Research Equipment Limnology Oceanography Hydrobiology Manual for plankton pump 1 x 230 VAC/2,2 KWatt Model no. 23.580 KC-Denmark is not, and cannot

More information

frequently asked questions

frequently asked questions Hydra Pilot Fault Codes What do the fault codes for the Hydra Pilot mean? Fault Cause FAULT 100 FAULT 101 FAULT 102 FAULT 103 FAULT 104 FAULT 105 FAULT 106 FAULT 108 FAULT 109 FAULT 110 FAULT 111 FAULT

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

3M Electrial Markets Division EMS. Electronic Marker System

3M Electrial Markets Division EMS. Electronic Marker System 3M Electrial Markets Division EMS Electronic Marker System 3M EMS Electronic Marker System The 3M Electronic Marker System helps eliminate guesswork. 3M markers operate even in the presence of metal conduits

More information

THERMAL MASS FLOW MEASUREMENT FOR GASES

THERMAL MASS FLOW MEASUREMENT FOR GASES THERMAL MASS MEASUREMENT FOR GASES Make the Wise Choice. Choose Sage Flow Meters. A Commitment to Higher Performance SAGE METERING is a manufacturer of high performance Thermal Mass Flow Meters which measure

More information

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Cover Page for Lab Report Group Portion. Head Losses in Pipes Cover Page for Lab Report Group Portion Head Losses in Pipes Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 February 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section

More information

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes Module 2, Add on Lesson Depth Sensor 90 minutes Teacher Purpose of this lesson Investigate the relationship between pressure and depth Construct a sensor to measure the depth of water Graph data and reason

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Instrumentation & Data Acquisition Systems

Instrumentation & Data Acquisition Systems Instrumentation & Data Acquisition Systems Section 3 -Level Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 Level Section Question Which level measuring technology is the best solution when

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

DURRIDGE STAINLESS STEEL SOIL GAS PROBE

DURRIDGE STAINLESS STEEL SOIL GAS PROBE DURRIDGE STAINLESS STEEL SOIL GAS PROBE CONTENTS 1. Introduction... 3 2. Placement... 3 3. Connection... 4 4 Measurement... 4 4.1 GRAB Protocol... 5 4.2 Continuous Monitoring... 6 4.3 Thoron Protocol...

More information

How to Make a Unique Industrial-Looking PVC Lamp

How to Make a Unique Industrial-Looking PVC Lamp How to Make a Unique Industrial-Looking PVC Lamp copyright 2014 by Brooks Owen Owen Publications Battle Ground, WA 98604-0305 USA ALL RIGHTS RESERVED No part of this publication may be reproduced or transmitted

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

955108_2. AirForce Operator s Guide

955108_2. AirForce Operator s Guide 955108_2 AirForce Operator s Guide Contents System Setup and Operation...3 AirForce Setup...3 Load Cells...6 AirForce Control...8 How to Set AirForce...11 Home Screen...13 AirForce Diagnostic Information...15

More information

Air Ball! Evaluation copy

Air Ball! Evaluation copy Air Ball! Computer 24 Do you ever wonder how the National Basketball Association (NBA) decides how much air should be in the basketballs used during a game? The NBA measures the pressure inside the ball

More information

Royce Interface Level Analyzer and Sensors

Royce Interface Level Analyzer and Sensors Royce Interface Level Analyzer and Sensors Model 2511A Interface Level Analyzer The Model 2511A is capable of having the ultrasonic speed of sound signal from its transducers changed by the user in applications

More information

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE Exercise 8 Closed-Loop Pressure Control, EXERCISE OBJECTIVE To understand open and closed-loop pressure control; To learn how to sense the pressure in a pneumatic circuit; To control the pressure in a

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

TH-1800-T TRX-700-CNG Converter

TH-1800-T TRX-700-CNG Converter TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter

More information