Technical Information
|
|
- Allan Johns
- 5 years ago
- Views:
Transcription
1 Technical Information Conductivity nalyzer Selection Guide Conductivity / Resistivity nalyzers Model SC4J Model SC8SG Model SC10G dapter Mounting Flow-through Model SC450G Four-wire Conductivity Model FLX1 Modular Two-wire Conductivity Model SC0G, S, SJ *1 Two-wire Conductivity Model SC100 Panel mounted Conductivity nalyzers Model ISC40GJ, S, SJ *1 Sensor Model ISC450G Four-wire Model FLX1 Modular Two-wire Inductive Conductivity Model ISC0G, S, SJ *1 Two-wire Inductive Conductivity (*1) Model SC0SJ, ISC0SJ and ISC40SJ are available only in Japan. Yokogawa Electric Corporation -9-3 Nakacho, Musashino-shi, Tokyo , Japan Tel.: Fax.: st Edition, Dec. 008 (YK)
2 <Toc> <Ind> Conductivity nalyzer Selection Guide Conductivity Sensor Selection Guide and Compatible Instruments Model Name Specifications SC4J-r-rrrr-00 SC4J-r-rrrr-010 -Electrode System SC10X SC8SG-R31-T SC8SG-R61-T Cell constant 0.0 cm cm cm cm cm -1 Minimum measuring range 0 to 0.5 µs/cm 0 to 100 µs/cm* 1 0 to 5 µs/cm 0 to 500 µs/cm* 0 to 00 µs/cm 0 to 0.5 µs/cm 0 to 1 ms/cm Maximum measuring range 0 to 00 µs/cm 0 to 1000 µs/cm* 1 0 to 1000 µs/cm 0 to 5000 µs/cm* 3 0 to 000 µs/cm 0 to 100 µs/cm 0 to 1000 ms/cm Process temperature 0 to 110 C 0 to 110 C 0 to 70 C 0 to 100 C 0 to 100 C Process pressure 0 to 1 MPa 0 to 1 MPa 0 to 500 kpa 0 to 1 MPa* 4 0 to 1 MPa* 4 Cable length 3/5/10/15/0 m No extension cable available 3/5/10 m Extension cable* 5 5.5/10/0 m No extension cable available Installation dapter mounting type Welding socked type Clamp type Drop- in type Piping connection with optional adapter Screw-in type Flow-through type (screw) Flow-though type (flange) pplications High purity water ( µs/cm) X X Tap water, industrial water X Industrial effluent, sewage X X X X cid/alkaline solution, brackish water, seawater X X X X X Food processing plant (interface detection)* 6 X X X X X Food processing plant (control of cleaning chemicals) X X X X X / Compatibility SC450G 4-Wire Conductivity/Resistivity X FLX1/SC0G -Wire Conductivity/Resistivity X SC0SJ -Wire Conductivity/Resistivity X SC0S -Wire Conductivity/Resistivity X SC100 Panel Mount Conductivity X X ISC450G 4-Wire X X X X X FLX1/ISC0G -Wire X X X X X ISC0SJ -Wire X X X X X ISC0S -Wire X X X X X Rating: =Recommended, =pplicable, X=Not applicable *1: Measuring range when used in conjunction with SC100 Panel Mount Conductivity. In this case, only titanium sensor can be used. *: Minimum measuring range when used in conjunction with SC100. *3: Maximum measuring range when titanium sensor is used in conjunction with SC100. Maximum measuring range when SUS316L sensor is used in conjunction with SC100 is 0 to 1000 µs/cm. *4: In case of PP (polypropylene) chamber, process pressure range is 0 to 500 kpa. *5: Total length including extension cable should not exceed 50 m. *6: Use SC500 Sanitary Conductivity. SC500 is available only in Japan. Conductivity / Selection Guide Model Name SC450G FLX1/SC0G SC0SJ *1 SC0S SC100 Product Name Installation Site 4-Wire -Wire -Wire -Wire Panel Mount Conductivity/Resistivity Conductivity/Resistivity Conductivity/Resistivity Conductivity/Resistivity Conductivity Indoors Outdoors (non-hazardous area) X Outdoors (hazardous area) X X X pplication For integration, small-scale instrumentation General purpose, medium-scale instrumentation Remotely located instrument panel room X Rating: =Recommended, =pplicable, X=Not applicable *1: This product is TIIS Intrinsically Safe type and available only in Japan
3 <Toc> <Ind> Conductivity nalyzer Selection Guide -Electrode System 4-Electrode System System SC10G- SC10G- SC8SG-R61-F ISC40GJ ISC40SJ ISC40S Model Name Specifications 0.05 cm -1 5 cm cm -1 Cell constant 0 to 0.5 µs/cm 0 to 00 µs/cm 0 to 1 ms/cm 0 to 100 µs/cm 0 to 100 µs/cm 0 to 100 µs/cm Minimum measuring range 0 to 00 µs/cm 0 to 0 ms/cm 0 to 1000 ms/cm 0 to 1999 ms/cm 0 to 1999 ms/cm 0 to 1999 ms/cm Maximum measuring range 0 to 100 C 0 to 100 C 0 to 100 C -10 to 130 C -10 to 130 C -10 to 130 C Process temperature 0 to 1 MPa* 4 0 to 1 MPa* 4 0 to 1 MPa* 4 0 to MPa 0 to MPa 0 to MPa Process pressure 3/5/10/15/0 m No extension cable available 5.5/10/0 m No extension cable available Screw in type Flange type Screw-in type Flow-through type (screw or flange) Flow-through type (screw) Screw in type with gate valve Flow-through type (flange) 5/10/15/0 m Extension cable* 5 5/10/15/0 m No extension cable available with optional screw-in adapter with optional flange adapter with optional immersion type holder 5/10/15/0 m No extension cable available Cable length Installation pplications X X X X X High purity water ( µs/cm) Tap water, industrial water X Industrial effluent, sewage X X X cid/alkaline solution, brackish water, seawater X X X X X X Food processing plant (interface detection)* 6 X X X Food processing plant (control of cleaning chemicals) / Compatibility X X X SC450G 4-Wire Conductivity/Resistivity X X X FLX1/SC0G -Wire Conductivity/Resistivity X X X SC0SJ -Wire Conductivity/Resistivity X X X SC0S -Wire Conductivity/Resistivity X X X X X X SC100 Panel Mount Conductivity X X X X X ISC450G 4-Wire X X X X X FLX1/ISC0G -Wire X X X X X ISC0SJ -Wire X X X X X ISC0S -Wire Rating: =Recommended, =pplicable, X=Not applicable *1: Measuring range when used in conjunction with SC100 Panel Mount Conductivity. In this case, only titanium sensor can be used. *: Minimum measuring range when used in conjunction with SC100. *3: Maximum measuring range when titanium sensor is used in conjunction with SC100. Maximum measuring range when SUS316L sensor is used in conjunction with SC100 is 0 to 1000 µs/cm. *4: In case of PP (polypropylene) chamber, process pressure range is 0 to 500 kpa. *5: Total length including extension cable should not exceed 50 m. *6: Use SC500 Sanitary Conductivity. SC500 is available only in Japan. ISC450G FLX1/ISC0G ISC0SJ *1 ISC0S Model Name 4-Wire -Wire -Wire -Wire nductive Conductivity Transmitte Product Name Installation Site Indoors Outdoors (non-hazardous area) X X Outdoors (hazardous area) pplication For integration, small-scale instrumentation General purpose, medium-scale instrumentation Remotely located instrument panel room Rating: =Recommended, =pplicable, X=Not applicable *1: This product is TIIS Intrinsically Safe type and available only in Japan
4 <Toc> <Ind> 4 Four-wire Conductivity / Resistivity nalyzers Conductivity Sensors Conductivity SC4J SC8SG SC450G dapter Mounting Welding Socket Welding Clamp SC10G Flow-through Flange Flow-through with Gate Valve Panel mounted Conductivity nalyzer Conductivity Sensor Conductivity SC10X Dedicated Conductivity Sensor SC100 WT100-SC Terminal ox Note: Terminal box and extension cable are used where converter is installed remotely more than 10 m from sensor. SC10X Optional dapter (when "/DP" option is specified) WF100-SC Extension Cable Note: SC4J -electrode Conductivity Sensor may be used.
5 RD -800 C 3 1 RD -800 C 3 1 RD -800 C 3 1 <Toc> <Ind> 5 Two-wire Conductivity / Resistivity nalyzers Non-explosionproof type Conductivity Sensors Conductivity SC4J SC8SG FLX1 Dedicated PH01G dapter Mounting Welding Socket Welding Clamp SC10G Screw-in Flow-through SC0G Failure contact output Maintenance contact output General SDT, SDS Flange Flow-through with Gate Valve Explosionproof type Conductivity Sensors Conductivity SC4J SC8SG Safety arrier RD800 Dedicated PH01G SC0SJ *1 Safety arrier RD800 Failure contact output Maintenance contact output General SDT dapter Mounting Welding Socket Welding Clamp SC10G Screw-in Flow-through SC0SJ *1 Safety arrier * SC0S * Flange Flow-through with Gate Valve (*) For intrinsically safe approval, use the safety barrier certified by the testing laboratories. In case of non-incendive type (SC0S-, -N, -D), the safety barrier is not neccessary. (*1) This product is TIIS Intrinsically Safe type and available only in Japan.
6 <Toc> <Ind> Four-wire nalyzer Sensor Holders Immersion ISC40FDJ ISC450G ISC40GJ Flow-Through ISC40FFJ Terminal ox Terminal ox 0 Direct Insertion ISC40FSJ Extension Cable WF10J
7 RD -800 C 3 1 RD RD <Toc> <Ind> Two-wire nalyzers Non-explosionproof type Sensor Holders Immersion ISC40FDJ FLX1 Dedicated PH01G Terminal ox ISC40GJ Flow-Through ISC40FFJ Terminal ox 0 ISC0G Failure contact output Maintenance contact output General SDT, SDS Direct Insertion ISC40FSJ Extension Cable WF10J Explosionproof type Sensor Holders ISC40SJ-TT *1 Immersion ISC40FDJ ISC0SJ *1 Safety arrier RD80 Dedicated PH01G SUPPLY Failure contact output Maintenance contact output Flow-Through ISC40FFJ ISC0SJ *1 Safety arrier RD80 General SDT SUPPLY Direct Insertion ISC40FSJ Safety arrier * ISC40S ISC0S * (*) For intrinsically safe approval, use the safety barrier certified by the testing laboratories. In case of non-incendive type (ISC0S-, -N, -D), the safety barrier is not neccessary. (*1) This product is TIIS Intrinsically Safe type and available only in Japan.
8 8 Revision Information Title Manual No. : Conductivity nalyzer Selection Guide : Dec. 008/1st Edition Newly published Dec.6,008-00
General Specifications
General Specifications DOG Optical Dissolved Oxygen Sensor GENERA DOG optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effl uent activated
More informationSCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE
SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE 1 TABLE OF CONTENTS 1. PURPOSE OF SUPPLY... 3 2. SYSTEM FUNCTIONING... 3 3. SYSTEM COMPONENTS... 4 4. BATTERY LIMITATIONS... 6 5. DOCUMENTATION...
More informationSanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems
Pneumatic Retractable Fittings SensoGate W 3 H Sanitary pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation offers genuine plug & play. The central
More informationGeneral Specifications
General Specifications GS 34P02P32-01E Gas Flow Calculation Portfolio (FCN-500) GENERAL This general specification document describes the Gas Flow Calculation Portfolio for FCN-500 on FCN autonomous controllers.
More informationHitachi Differential Pressure/Pressure Transmitter
Hitachi Differential Pressure/Pressure Transmitter Hitachi Differential Pressure/Pressure Transmitter Series is based on our accumulated technology and is available in many types. This instrument is expected
More informationCCT-7320/ROC-2313 Reverse Osmosis Controller
CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation
More informationJUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)
Data Sheet 202610 Page 1/12 JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO) with optional terminal box or operating unit Type 202610 Two-wire transmitter JUMO dtrans O2 01 Brief description
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationPneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas
Pneumatic Retractable Fittings Pharm Food SensoGate W 3 H Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas Easy installation and clear hose connections offers
More informationdtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationGeneral Specifications
General Specifications GS 34P02P31-02E Gas Flow Calculation Portfolio (FCN-RTU) GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN-RTU low power autonomous
More informationUser s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E
User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual
More information200A Series ELECTRONIC LEVEL TRANSMITTER
MARINE - WATER AND PROCESS INDUSTRIES LIQUID LEVEL AND CONTENTS APPLICATIONS HYDROSTATIC OPERATION 200A Series ELECTRONIC LEVEL TRANSMITTER INTRINSICALLY SUBMERSIBLE - SCREWED MARINE SAFE FLANGED - HYGIENIC
More informationGeneral Specifications
General Specifications Model ISC40 Inductive Conductivity sensor and fittings The model ISC40 sensors are designed for use with the EXA: ISC0 2-wire transmitters and the EXA: ISC402 4-wire analyzers. This
More informationBest Practice for Calibrating LTH Conductivity Instruments
Application Note Best Practice for Calibrating LTH Conductivity Instruments As accurate process measurement becomes an everyday requirement it is vital to be able to calibrate conductivity instruments
More informationProduct information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983
Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...
More informationOxymax COS61/COS61D. Technical Information
Technical Information Oxymax / Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle, with or without Memosens protocol Application The continuous measurement of the
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option
ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationGeneral Specifications
General Specifications Gas Flow Calculation Portfolio GS 34P02P31-01E GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN/FCJ autonomous controllers. Using this
More informationHigh-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationPreparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable
GEP-6075 Rev. B 101574 Ref. I.D.: 16973 Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE
More informationModel 1159 Remote Diaphragm Seals Manual
00809-0100-4504 English June 1999 Rev. AB Model 1159 Remote Diaphragm Seals Manual With Model 1152, Model 1153 Series B, D, and F, and Model 1154 Alphaline Nuclear Pressure Transmitters Product Discontinued
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More informationTANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box
TANKTRONIC STANDARD CONFIGURATION Single Tank control unit Twin Tank (common valve) control unit Twin Tank (separate valves) control unit ADVANCED CONFIGURATION Multiple Tanks control unit S-Module Tanktronic
More informationGeneral Specifications
General Specifications GS 34P02P31-01E Gas Flow Calculation Portfolio (FCN-100/FCN-RTU/FCJ) GENERAL This general specification document describes the Gas Flow Calculation Portfolio on FCN/FCJ autonomous
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationPneumatic retractable fitting for simple commercially available control units or process applications
Pneumatic Retractable Fittings hem Energy Pharm Food Water SensoGate W 3 Pneumatic retractable fitting for simple commercially available control units or process applications Variable and reasonably priced
More informationISC40G(S) with external
ISC40G(S) with external temperature e sensor ISC40G(S) with external temperature sensor To get a more stable and faster reacting temperature reading, Insatech have designed a small solution with a termowell
More informationCOSMO INSTRUMENTS CO., LTD.
Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time
More informationLiquid level instruments BM 24 /BM 51
KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationRosemount 400 and 400VP
Rosemount 400 and 400VP Contacting Conductivity Sensors Instruction Manual LIQ-MAN-400 Rev. L May 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and
More informationMAGNETIC FLOAT SENSOR
TS02-0143 I N S T R U C T I O N M A N U A L F O R MAGNETIC FLOAT SENSOR MODEL:FR Revision 2015-04-17 Read and understand this manual for safely usage. This manual describes the product of standard specification.
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationTechnical Information Conducal CLY421
TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified
More informationTEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL
Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter
More informationImprove Process Reliability
Convenient Conductivity Calibration to Meet Pharmacopeia Regulations Pharmacopeias require that conductivity measurement systems be periodically calibrated to ensure their precision. The range of accessories
More informationDifferential Pressure Level Solutions. Bulletin 01C25A04-01EN-Y
Differential Pressure Level Solutions Bulletin 01C25A04-01EN-Y Differential Pressure Level Solutions Liquid tank level is one of the basic measurements used in process plants but, its importance cannot
More informationPK200 Current-to-Pneumatic Converter [Style:S2]
User s Manual PK200 Current-to-Pneumatic Converter [Style:S2] 13th Edition i PK200 Current-to-Pneumatic Converter [Style:S2] 13th Edition Contents Introduction...iii 1. Handling Precautions... 1-1 1.1
More informationSPD310/SPD360 Air Differential
SPD310/SPD360 Air Differential Pressure SPD310 / SPD360 SPD310 / SPD360 differential pressure transmitters are intended for use in air handling systems for the monitoring of air ducts, filters and fans.
More informationEC214 EC215 - EC215R Bench Conductivity Meters
Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments
More information2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor
INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters Features Include Base accuracy : ±0.075% Span limits
More informationPneumatic Outflow Control
Technical Bulletin Pneumatic Outflow Control Pneumatically powered controls for the precise limitation of the volumes of waste water and rain water Contents Applications... 3 Success features... 4 Technical
More informationI/P Transducer Positioner Module
I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES
More informationFlow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS880 (retrofit kit) 4/275. Overview
Siemens G 2010 Overview pplication Irrigation systems Irrigation distribution systems Pumping stations Canal laterals On-farm outlets Water well production rip and sprinkler irrigation Center pivot systems
More informationDigital Flow Switch. Series PFM7
Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow
More informationPART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:
PART 1 GENERAL 1.1 DESCRIPTION.1 This section includes the supply, delivery and installation, testing and placement into operation of a gas chlorination system, and appurtenances as specified herein and
More informationGeneral Specifications
General Specifications YVP110 Advanced Valve Positioner GS 21B04C01-01E FEATURES Model YVP110 FOUNDATION fieldbus TM Valve Positioner accepts digital communication to control a pneumatic actuator mounted
More informationph measuring system for hygienic process applications
ph measuring system for hygienic process applications Sterile design, CIP-compatible, in-line sterilizable Extremely robust and unbreakable construction Extremely long service life Long calibration intervals
More informationCONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES
I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical
More informationFree Chlorine Sensor For additional information, please visit our website at
Instruction Manual 499ACL01 LIQ_MAN_ABR_499ACL01 April 2014 Free Chlorine Sensor For additional information, please visit our website at www.rosemountanalytical.com. CAUTION Sensor/Process Application
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationWATER INJECTION SYSTEMS - CORROSION MONITORING
Corrosion Management WATER INJECTION SYSTEMS - CORROSION MONITORING Overview Water, used for well injection is normally treated seawater and thus it is critical to control the corrosivity of the fluid,
More informationAMT-Ex Dewpoint Transmitter
AMT-Ex Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationCalibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.
Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up
More informationKube Engineering Quinn E. Eddins, B.S.E.E Phone
Process Information: There are four ph assemblies used to monitor the ph value on a Sulfur Dioxide absorber. The chemical composition is approximately 20-30% Sodium Bisulfite, 4% Sodium Sulfite, and the
More informationFLAMMABLE GAS SENSOR/TRANSMITTER
FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.
More informationHI 2314 HI 2315 HI 23151
Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More informationRosemount 3159 Nuclear Qualified Remote Diaphragm Seal
Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal FOR USE ON ROSEMOUNT 3152, 3153, AND 3154 TRANSMITTERS Qualified per: o IEEE Std 323-1974/1983/2003 o IEEE Std 344-1975/1987/2004 112 Mrad (1.12 MGy)
More informationWatMan WATER RO SYSTEMS FOR DESALINATION
WatMan WATER RO SYSTEMS FOR DESALINATION The WatMan reverse osmosis systems produce from 1 to 2000 m 3 per day of high quality water suitable for communities, marine environment, boiler feed and general
More informationLevel MEASUREMENT 1/2016
Level MEASUREMENT 1/2016 AGENDA 2 A. Introduction B. Float method C. Displacer method D. Hydrostatic pressure method E. Capacitance method G. Ultrasonic method H. Radar method I. Laser method J. Level
More informationPressure transmitter PASCAL Ci4
Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution
More informationInstruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes
Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes Instruction Bulletin Addendum IB PB1000 Part no. Serial no. Order no. Oxymitter 4000 Applicability: Used with pressure-balancing
More informationIECEx Certificate of Conformity Annexe
for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment
More informationSuccessful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.
INSTRUMENTATION COURSE 510: 3 DAYS: Max 8 Candidates This course covers the key aspects of industrial instrumentation and is designed to enable maintenance personnel to carry out commissioning, calibration
More informationBest Practice Guide, Servomex 2700
For full installations details refer to the. Best Practice Guide, Servomex 2700 Mounting: General Guidelines: Servomex 2700 Control Units and air supplies (utilities units) should, ideally, be mounted
More informationDifferential pressure
Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor
More informationDissolved Oxygen Cartridge Electrode Systems
Instruction Manual IM/9408 CAR_3 Dissolved Oxygen Cartridge Electrode Systems 9408 8000 Series ABB The Company EN ISO 9001:1994 We are an established world force in the design and manufacture of instrumentation
More informationINSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.
HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO.,LTD 141, Palhakgol-gil, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (00)-82-31-950-9700 FAX. : (00)-82-31-943-5600 www.hitrol.com INSTRUCTION
More informationPneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems
Pneumatic Retractable Fittings SensoGate WA 3 Pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation SensoGate WA 3 offers genuine plug & play. The
More informationColumbus Instruments
0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011
More informationRosemount 140/141/142
Rosemount 140/141/142 Contacting Conductivity Sensors Instruction Manual LIQ-MAN-140 Rev. F May 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and tests
More informationR84G - Excelon Plus Modular System Pressure regulators
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Easy to read flush mounted integrated pressure gauge as
More informationUltrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63
Ultrasonic 58 Overview VEGASON 60 VEGASON 61, 62, 63 57 Overview VEGASON Area of application The ultrasonic sensors of the VEGASON series are suitable for non-contact level measurement of liquids and bulk
More informationVortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas
Vortex Flow Meter Wafer or Flange Connection - Steam - Liquid - Gas Working Principle & Circuit Diagram Working Principle When a column body placed in flowing fluids in pipe, a series of vortices will
More informationModel ZX8D Zirconia Oxygen Analyzer
User s Manual Model ZX8D Zirconia Oxygen Analyzer IM 11G00E01-01EN IM 11G00E01-01EN 6th Edition u Introduction Thank you for purchasing the ZX8D Zirconia Oxygen Analyzer. Please read the following respective
More informationMODEL GT820 OXYGEN SENSOR
INSTRUCTION MANUAL MODEL GT820 OXYGEN SENSOR 70046 The information and technical data disclosed by this document may be used and disseminated only for the purposes and to the extent specifically authorized
More informationRadar, Ultrasonic and RF Level Transmitters
Radar, Ultrasonic and RF Level Transmitters Both measures the time it takes the wave to travel between the transmitter and that reflected wave off the surface of the material to reach the transmitter again.
More informationPURA. Pure Gas Dewpoint Transmitter. Users Guide
PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter
More informationTransmitter CS 21 Operation Manual
Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical
More informationTechnical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?
Technical Datasheet Pressure Transmitter: Analogue Series 387 387 ISSUE G High Accuracy ± 0.15%. Ranges from 1 bar to 1000 bar. 4 : 1 turndown. 4-20mA analogue with digital communications. 316 stainless
More informationModel PDT Dewpoint Transmitter
Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationLiquid Level Measurement
Technical Article Liquid Level Measurement A pressure transmitter can be used to determine the liquid level in a tank, well, river or other body of liquid. The pressure at the bottom of a liquid filled
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationModel 575 and 575P Submersible Level Transmitters. Model 675 Submersible Level Transmitters. Model SDT Submersible Level Transmitters
Model 575 and 575P Submersible Level Transmitters Class I, Div 1 Approvals Standard or flush diaphragms for easy of cleaning Measurement ranges up to 690 of water Protected flush option available with
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX HHV-E Vortex Driven Regulator HYDROVEX HHV-E VORTEX DRIVEN REGULATOR APPLICATION The hydro electronic HYDROVEX HHV driven regulator, type E is specially designed for
More informationWATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL
Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.
More informationellison sensors international
PR3900 HAZARDOUS AREA PRESSURE TRANSMITTER ATEX CERTIFIED AND ALL EQUIVALENTS FOR HAZARDOUS AREAS: ZONE 0 GAS GROUP IIC, TEMPERATURE CLASS T4 AND ZONE 20 DUST PROTECTION BY INTRINSIC SAFETY TO EEXIA IIC
More informationVariable Area Flowmeter Rotameter The Original
RAGK/RAGL/RAGH RAKD/RAMC Variable Area Flowmeter Rotameter The Original Precise measurement of liquids and gases Robust and universal Proven device with an installed base of more than 1,000,000 worldwide
More informationLK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal
LK-SX CO 2 +VOC Sensor for detection of carbon dioxide (CO 2) and mixed gas content in air ducts Data sheet Subject to technical alteration Issue date: 24.08.2015 Application For detection of CO2 and VOC.
More informationManual retractable fitting with safe-to-operate rotary drive
Manual Retractable Fittings SensoGate W M Manual retractable fitting with safe-to-operate rotary drive Revolutionary operation The SensoGate W M has a manual rotary drive, which enables the fitting to
More information9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs
Data sheet DS/9408 EN Rev. M 9408 Series Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling design minimizes operational costs Low maintenance,
More informationCoriolis Mass Flow Meter
Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;
More information