Accessories for Sanitary Installations

Size: px
Start display at page:

Download "Accessories for Sanitary Installations"

Transcription

1 5. Accessories for Sanitary Installations Flamco s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the safety valve will open to prevent a further rise in pressure. Prescor valves are produced in a variety of fitting sizes and pressure ratings. The materials and construction of Flamco B safety valves are of the highest quality to ensure total safety and peace of mind. They can be used in combination with any boiler system. 132 Product overview 2013 We reserve the right to change designs and technical specifications of our products.

2 Accessories for Sanitary Installations 5 Product overview 2013 We reserve the right to change designs and technical specifications of our products. 133

3 Prescor Boiler Valves The Highest Quality of System Protection The Prescor B and SB boiler valves protect sealed mains water systems against excess pressure. Such a safeguard is a requirement because of the expansion of system water and the presence of a non-return valve. Of course, water cannot be compressed, so without this sort of safeguard the pressure in the system could rise to a dangerous level. Local regulations and standards and water pressures must be observed when using Prescor B and Prescor SB valves at all times. Cap for lifting the valve. Spring for setting the pressure of the safety valve. Diaphragm that prevents moisture and dirt from getting into the moving parts. Valve with rubber seal. PRESCOR B Benefits Solid brass housing. Wide range, so the right valve can be used at all times. Because of the ''pop'' effect a high blow-off capacity. Can be used in combination with any storage boiler system. Construction and choice of materials are your guarantee of safety. N.B. Prescor boiler valves must not be installed with the discharge port facing upwards. OK XWRONG 134 Product overview 2013 We reserve the right to change designs and technical specifications of our products.

4 Accessories for Sanitary Installations 5 How It Works When the system pressure reaches the set pressure, the Prescor B boiler valve begins to vent, whereby the pressure stops rising. If, due to specific circumstances, the pressure rapidly rises over the set pressure, the Prescor B boiler valve will open fully, creating a large blow off capacity. This is a permanent, reliable safeguard against overpressure. Venting can be prevented by fitting a suitably sized Airfix expansion vessel for sanitary systems. The valve size of both the Prescor B and the Prescor SB is determined by the capacity and output of the boiler. Lifting lever. The set pressure of the safety valve is locked and cannot be changed. To prevent limescale, the moving parts must be kept dry in all circumstances. The diaphragm ensures this. All Prescor B and Prescor SB valves are individually tested to guarantee their function, and they comply with European Directive 97/23/EC, the Pressure Equipment Directive. PRESCOR SB Well Designed Technology and Application The seating of Prescor boiler valves is designed so that it not only makes a perfect seal, but can also achieve a large blow-off capacity. The hardness of the rubber is adapted according to the set pressure of the safety valve. Due to this combination of a specifically designed seating and special rubber, it is possible to achieve optimum safety. Product overview 2013 We reserve the right to change designs and technical specifications of our products. 135

5 PRESCOR B SAFETY VALVES For protecting water heaters and potable water systems. Prescor B Set pressure [bar] Inlet Connection Outlet Capacity [kw] Prescor B 1 / / 2" F 1 / 2" F Prescor B 1 / / 2" F 1 / 2" F Prescor B 1 / / 2" F 1 / 2" F Prescor B 3 / / 4" F 1" F Prescor B 3 / / 4" F 3 / 4" F Prescor B 3 / / 4" F 1" F Prescor B 3 / / 4" F 1" F Prescor B " F 1 1 / 4" F Prescor B " F 1 1 / 4" F Prescor B " F 1 1 / 4" F Prescor B " F 1 1 / 4" F Nr Prescor SB Set pressure [bar] Inlet Connection Outlet Capacity [kw] Prescor SB 1 1 / / 4" F 1 1 / 2" F Prescor SB 1 1 / / 4" F 1 1 / 2" F Prescor SB 1 1 / / 4" F 1 1 / 2" F Prescor SB 1 1 / / 2" F 2" F Prescor SB 1 1 / / 2" F 2" F Prescor SB 1 1 / / 2" F 2" F Prescor SB " F 2 1 / 2" F Prescor SB " F 2 1 / 2" F Prescor SB " F 2 1 / 2" F Nr AIRFIXCONTROL With this component the flushing function is fully guaranteed. When the vessel is disconnected from the system, the system flow remains in function. AirfixControl enables an easy yearly precharge check of the Airfix A or D expansion vessel. AirfixControl AirfixControl Product overview 2013 We reserve the right to change designs and technical specifications of our products.

6 Accessories for Sanitary Installations 5 WALL MOUNTING Flexcon DT To assist in mounting and removing Flexcon and Airfix vessels. A Application Dimensions A Flexcon DT Flexcon/Airfix SB-A Band For mounting an Airfix P expansion vessel (2-35 litres) to the wall. Application SB-A MB Band for fitting Airfix P vessels, to be combined with MB For mounting Flexcon/Airfix vessels of 8-25 litres. Provided with a slot into which the Flexcon vessel clamp ring fits precisely. Tightening the two bolts is all that is needed to make a sturdy connection. Material: DC01 A-m, zinc coated. Connection to the wall with two Ø8 plugs and two Ø6 screws with hexagon head (wrench 10). Connection of the vessel to the MB by means of two M5 bolts with cross head. Separately available are sets of 5 hose clamps for connection vessels without clench ring (size approx. Ø 325 mm). With spring and adapter for even more installation convenience. A B C Dimensions A B C Flexcon vessel support MB Flexcon vessel support MB Product overview 2013 We reserve the right to change designs and technical specifications of our products. 137

7 Flamco Safety Groups For Effective Safeguarding of Your System Combination Pressure Relief Valves and Safety Groups Apart from the Prescor B and Prescor SB boiler valves, Flamco also supplies different types of Prescor IC and Flexbrane safety groups. The Benefits of Prescor IC ½". Sound-class 1 approved. KIWA/Belgaqua certified. With ½" 15 mm compression fitting. Large flow capacity, so hardly any loss of pressure through the outlet. Tundish can be rotated through 360. Hence it can be fitted in almost any position. Compact, so recommended for built-in appliances. Non-return valve prevents water flowing back into the supply line. Opening for the non-return valve at the back. Relief valve. FLEXBRANE Block and bleed valve. Tundish. PRESCOR IC The tundish can be rotated through 360. Hence it can be fitted in almost any position. Compact model, modern design. 138 Product overview 2013 We reserve the right to change designs and technical specifications of our products.

8 Accessories for Sanitary Installations 5 SAFETY GROUPS For protecting the potable water system from excess pressure during the heating cycle. A non-return valve with inspection port will prevent the water (e.g. from a water heater) from flowing back into the mains water pipe Δ Pressure (bar) Prescor IC ½" Prescor IC ¾" Capacity (m 3 /h) Prescor IC For storage vessels up to [l] Set pressure [bar] Connection* Prescor IC 1 / 2 - solder w x 15 w x 22 c Prescor IC 1 / 2 - compression c x 15 c x 22 c Prescor IC 3 / 4 - solder w x 22 w x 28 c Prescor IC 3 / 4 - compression c x 22 c x 28 c * c = compression connection w = solder connection Flexbrane Set pressure [bar] Connection Flexbrane CE-H 3 / 4 hor. 7 3 / 4" F x 3 / 4" M x 1" M Flexbrane SST NF - ACS 7 3 / 4" F x 3 / 4" M x 1" M Flexbrane CF 1 hor. 7 1" F x 1" M x 1" M Plastic siphon for CE and connection piece 7 1" x 1" Product overview 2013 We reserve the right to change designs and technical specifications of our products. 139

9 Prevent Water Hammer Simply and Effectively The Flexofit water hammer arrestor has been specially developed to absorb water hammer in sanitary mains water systems and is made of chrome-plated brass. Some Possible Causes of Water Hammer A valve (or solenoid) or tap closing too quickly. The non-return valve. A pump that suddenly cuts in or out. Pressurized gas cushion. Rubber diaphragm. Water at system pressure T-piece. The Flexofit water hammer arrestor absorbs the wave of pressure before it can develop into water hammer. The Flexofit does this by having two areas that are separated by a rubber diaphragm. On one side, there is a gas cushion under pressure, while the other side is in connected to the system. The gas cushion compresses and absorbs the wave of pressure. 140 Product overview 2013 We reserve the right to change designs and technical specifications of our products.

10 Accessories for Sanitary Installations 5 Selection Table System pressure [bar] Pipe diameter Max. pipe length up to the 1 st bend [m] Number of Flexofit S water hammer arrestors to be fitted ½" (15 mm) ¾" (22 mm) " (28 mm) ¼" (35 mm) This table is based on a flow rate of 3 m/s. A Flexofit in the line leading to a urinal flusher In combination with a wash hand basin Used with a washing machine Water hammer can be described as a change in pressure in a sealed pipeline as a consequence of sudden changes in the flow speed of fluid in the system. This creates a wave of pressure that moves rapidly through the line. This wave of pressure may result in the creation of vibrations, noise or even a fracture in the pipe or serious damage to equipment and pumps. It is thus important to prevent water hammer. FLEXOFIT T-PIECE Product overview 2013 We reserve the right to change designs and technical specifications of our products. 141

11 FLEXOFIT S WATER SHOCK ARRESTOR Flexofit S absorbs water hammer in order to minimize noise and damage to the system. Solid brass, chromium plated housing. Maximum working pressure: 10.0 bar. Maximum working temperature: 90 C (363 K). Flexofit S Pre-charge [bar] Dimensions Connection Ø H. Flexofit S 1 / / 2" M Flexofit S T-fitting For mounting Flexofit water hammer arrestors quickly and easily between the tap and the washing machine or dish-washer. Connection T-fitting Flexofit S 3 / 4" F x 1 / 2" F x 3 / 4" M VESSEL CARRIER Vessel Carrier A handy vessel carrier which makes it very easy and safe to handle or transport the exchanged vessel. Easy to use. Prevents spilling of (polluted) heating installation water in your transporter or at home with the customer. The vessel can be handled with one hand only. Easy to be mounted and removed (for multiple use). Connection Application Vessel carrier 3 / 4" Flexcon/Airfix Product overview 2013 We reserve the right to change designs and technical specifications of our products.

Accessories for Potable Water Installations

Accessories for Potable Water Installations 5. ccessories for Potable Water Installations Flamco s Prescor safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the

More information

Expansion Vessels for Potable Installations

Expansion Vessels for Potable Installations 4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm

More information

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice

More information

Flexcon. Flamco. Flamco. Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON CE FLEXCON M FLEXCON V-B FLEXCON EXPANSION VESSELS

Flexcon. Flamco. Flamco. Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON CE FLEXCON M FLEXCON V-B FLEXCON EXPANSION VESSELS FLEXCON EXPANSION VESSELS Flexcon Diaphragm pressure expansion vessels FLEXCON C 2-80 FLEXCON CE 110 1000 FLEXCON M FLEXCON V-B 2005 edition / EXP Choose quality choose a Flexcon the choice of a satisfied

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

Airfix Pressure expansion vessels for sanitary appliances and potable water systems

Airfix Pressure expansion vessels for sanitary appliances and potable water systems airfix expansion vessels Your reliable partner 4 Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E AIRFIX P Edition EXP 2009 Flamco offers you

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2015. All rights reserved. No part of this publication may be reproduced by

More information

Flexvent floatvents: reliable and easy to mount

Flexvent floatvents: reliable and easy to mount floatvents: reliable and easy to mount The floatvents /80, /80 - /80, /20 and /40 are supplied together with a shut-off valve to facilitate mounting and removal. When the floatvent is unscrewed from the

More information

Engineering Data Sheet

Engineering Data Sheet Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate

More information

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution

More information

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Main features Designed for automatic filling of sealed heating systems and for protection of the water mains from risk of contamination.

More information

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS THE COMPANY ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and

More information

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS POP Safety Valve POP Safety Valve INTRODUCTION The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant and personnel. Safety

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Flamco. Flamco. Flamco. Accessories for heating systems PRESCOR PRESCOR S FLEXCON THERMO-PRESSURE GAUGE FLEXFAST FLEXCONSOLE

Flamco. Flamco. Flamco. Accessories for heating systems PRESCOR PRESCOR S FLEXCON THERMO-PRESSURE GAUGE FLEXFAST FLEXCONSOLE HETING SYSTEM ESSORIES ccessories for heating systems PRESOR PRESOR S FLEXON THERMO-PRESSURE GUGE FLEXFST FLEXONSOLE 2005 Edition / EXP complete programme for the protection of Prescor safety valves are

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and

More information

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap 0509950/2 IM-P050-21 CH Issue 2 Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and

More information

HL Hydraulik GmbH Kupferhütte 5c D Herdorf Tel Fax

HL Hydraulik GmbH Kupferhütte 5c D Herdorf Tel Fax SAFETY VALVES TYPE SVE06 www.hlhydraulik.de D57562 Herdorf Tel 0274493240 Fax 02744932456 schrupp@hlhydraulik.de SAFETY VALVE TYPE V600 ORDERINGNO SVE06 87202 Application: Schrupp safety valves type SV061

More information

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications SAPAG A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications Features The Sapag Series 1100 steam safety valve is used for

More information

High Performance BSP Dial Up Pattern Pressure Reducing Valve

High Performance BSP Dial Up Pattern Pressure Reducing Valve See our full range online at: www.vip-ltd.co.uk High Performance BSP Dial Up Pattern Pressure Reducing Valve VIP Product Code 31/0103 FUNCTION Pressure reducing valves are devices which, when installed

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09 PRESSURE TEST PUMP Model No: PTP00 Part No: 06020 OPERATING & MAINTENANCE INSTRUCTIONS GC0/09 INTRODUCTION Thank you for purchasing this CLARKE Pressure Testing Pump. Before attempting to use the product,

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

1800C and 1800C-HC Series Service Regulators

1800C and 1800C-HC Series Service Regulators 1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief

More information

Pressure surge absorption

Pressure surge absorption Pressure surge absorption Product range for drinking water, waste water and the chemical industry With remote monitoring, everything is fully under control. Willy Zahnd, WARET AG PRESSURE SURGE ABSORPTION

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions.  IMPORTANT NOTICE SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5

More information

INSTRUCTION MANUAL. January 23, 2003, Revision 0

INSTRUCTION MANUAL. January 23, 2003, Revision 0 INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,

More information

S300 Series. Valve Link. Features. Fisher Controls

S300 Series. Valve Link. Features. Fisher Controls S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a

More information

756 Safety Relief Valves

756 Safety Relief Valves 756 S a fe t y R e l i e f Va l ve s INTRODUCTION 756 Safety Relief Valves The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix Pump Dimensions A B C D F H I J K L P300 18.90" 22.83" 31.50" 3.94" 15.28" 27.17" 1.57" 2.95" 15.55" 19.49" (480 mm) (580 mm) (800 mm)

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making

More information

Bar valve with fixed shower head Installation guide

Bar valve with fixed shower head Installation guide Midas Plus Mono Bar valve with fixed shower head Installation guide Midas Plus Mono Midas Plus Mono Components Literature not shown Important information Introduction The Midas Plus Mono product is an

More information

SV5 Safety Valve Installation and Maintenance Instructions

SV5 Safety Valve Installation and Maintenance Instructions 3120036/3 IM-S13-12 CH Issue 3 SV5 Safety Valve Installation and Maintenance Instructions 1. General specification 2. Supply 3. Before fitting the valve 4. Installation 5. Damage prevention 6. Commissioning

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION This Fitting Guide is designed to assist in the Installation of your Reverse Osmosis System. Some of the parts that are supplied with each system may

More information

1200B2 Series Service Regulators. Instruction Manual

1200B2 Series Service Regulators. Instruction Manual 00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available

More information

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GS-20/25 GS-40/45 Issue Date 1298 GS-20/25 and GS-40/45 Series Single-block Multi-function Gas

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

Regulator from 1800 B series

Regulator from 1800 B series Regulator from 1800 B series Regulator from 1800 B series Measuring of industrial gases frequently requests a precise pressure regulation for the purpose of dosage and proccesing. UNIS FAGAS has two kinds

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

Flexvent. Venting range and dirt separators. Air pots LTA

Flexvent. Venting range and dirt separators. Air pots LTA Flexvent H / 20 Flexvent H white / 20 Flexvent top Flexvent top white Flexvent max Flexvent super / 20 LUCHTPOT LTA Air pots LTA The Flamco air pot is mounted on rising pipes in the supply or return pipe.

More information

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES Sampling Valves Installation Commissioning and Operating Instructions SD IL 300 & SD IL 400 Inline Sampling Valve This

More information

MEGR-1912 Instruction Manual

MEGR-1912 Instruction Manual MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX

More information

Materials : Brass body dezincification-resistant up to DN1 1/4

Materials : Brass body dezincification-resistant up to DN1 1/4 Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Male, Male BSP + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass body dezincification-resistant up to DN1 1/4 Controlable With male

More information

Universal Charging and Testing Unit FPU-1

Universal Charging and Testing Unit FPU-1 1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose

More information

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local

More information

Application and Sizing

Application and Sizing Application and Sizing Energy accumulator: It is improbable that an hydraulic system use all of its capacity without interruptions. An hydropneumatic accumulator can store a certain amount of fluid that

More information

Art PRESSURE REDUCER

Art PRESSURE REDUCER FUNCTION ICMA pressure reducers are devices that reduce and stabilize the incoming pressure from the water supply. Pressure reducers allow correct use on domestic systems, reducing malfunctions due to

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett

FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE. Gary S. Beckett FUNDAMENTALS OF PRESSURE RELIEF VALVES IN NATURAL GAS INSTALLATION - OPERATION - MAINTENANCE Gary S. Beckett Flow Safe Supply 10727 Tower Oaks Boulevard Houston, Texas 77070 What Are They and Why Are They

More information

TEC 1/2 3/4 DN A B C 32,25 32,25 F Kg/cm 2 bar LBS - psi

TEC 1/2 3/4 DN A B C 32,25 32,25 F Kg/cm 2 bar LBS - psi 360 A B F F C 1/2 3/4 DN 15 20 A 60 60 B 93 93 C 32,25 32,25 F 12 12 Kg/cm 2 bar 15 15 LBS - psi 218 218 360 10 9 8 7 6 5 11 12 13 1 2 3 4 Pos. DESCRIZIONE / DESCRIPTION Qt. MATERIALE / MATERIAL 1 Corpo

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 36454 and 364540 Hydrostatic Test Pumps 36454 DIMENSIONS: 24 (61cm) L x 19 (48cm) W x 19.5 (50cm) H WEIGHT: 135 lbs 61.5 kg PUMP: Twin piston: Positive displacement type Inlet

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions 488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet

More information

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

2.0 INSTALLATION & SERVICE

2.0 INSTALLATION & SERVICE Installation, Operation, and Maintenance Instructions MODEL 5600 / 5600R January 2005 CONTENTS 1.0 GENERAL 1.1 5600 Model Number Information -----------------------------------------------------------------------

More information

1800C and 1800C-HC Service Regulators

1800C and 1800C-HC Service Regulators SB 855.9 800C and 800C-HC Service Regulators Maximum Pressure 5 Table of Contents 800C Regulator Information...................... 800C-HC Regulator Information.................. 800C and 8C Service Regulators...............

More information

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

3/8" Dr. Air Butterfly Impact Wrench

3/8 Dr. Air Butterfly Impact Wrench 8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it The ECO 3F flanged backflow preventers, which have a

More information

Airfix D-E-B Installation and operating instructions

Airfix D-E-B Installation and operating instructions www.flamco.nt-rt.ru Airfix D-E-B Installation and operating instructions Dear Customer, With the Airfix D-E-B membrane expansion vessel you have acquired a Flamco quality product. This expansion vessel

More information

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435 Instruction manual Bermad surge anticipation manual Model No 435 Installation and operation Manual Bermad Surge Anticipation Valve Model No 435 Bermad Water Technologies Rev 0 5/05/2015 7 Inglewood Drive,

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information

64 Series Pressure Reducing Regulators

64 Series Pressure Reducing Regulators Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The

More information

Actuator HON 670 / 671

Actuator HON 670 / 671 Actuator HON 670 / 67 Product information serving the gas industry worldwide Applications, characteristics, technical data Application The actuators HON 670 (K6, K8) and HON 67 (K7) are used to trigger

More information

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM-20/25 GM-40/45 Issue Date 1298 UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function

More information

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM CLEFFI /7 GB replaces / GB Function Pressure reducing valves are devices which, when installed on private

More information

1305 Series Pressure Reducing Regulators

1305 Series Pressure Reducing Regulators Instruction Manual Form 1095 1305 Series October 2009 1305 Series Pressure Reducing Regulators! Warning Fisher regulators must be installed, operated, and maintained in accordance with federal, state,

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

RA-N radiator valves with integrated presetting and self-sealing tailpiece

RA-N radiator valves with integrated presetting and self-sealing tailpiece Data sheet RA-N radiator valves with integrated presetting and self-sealing tailpiece EN 215 Application Straight version Angle version Horizontal angle version All RA-N valve bodies can be used together

More information

Instructions for SILEX 1C Mixed bed cartridge filter

Instructions for SILEX 1C Mixed bed cartridge filter D01B-30A-UK1 January 2017 Instructions for SILEX 1C Mixed bed cartridge filter With conductivity sensor Gravity flow or pressure installation SILHORKO-EUROWATER A/S Phone +45 86 57 12 22 DK-8660 Skanderborg

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Probe Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

MANUAL. Sesame. Thermoplastic Tank Technologies

MANUAL. Sesame. Thermoplastic Tank Technologies MANUAL Sesame Thermoplastic Tank Technologies INSTALLATION AND USER GUIDE CONTENT 1. GENERAL 3 2. IMPORTANT 3 3. INSTALLATION EXPANSION VESSEL 4 4. USE EXPANSION VESSEL 5 5. AIR CELL REPLACEMENT 5 5.1

More information

Spirax Compact FREME Flash Recovery Energy Management Equipment

Spirax Compact FREME Flash Recovery Energy Management Equipment IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0

More information

APT14, APT14HC and APT14SHC Spares 2

APT14, APT14HC and APT14SHC Spares 2 6120251/7 IM-P612-06 ST Issue 7 APT14, APT14HC and APT14SHC Spares 2 Installation and Maintenance Instructions 1. Safety information 2. Replacement of trap and outlet check valve mechanism 3. Replacement

More information

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150, CARTRIDGE FILTERS Models: CF50, CF75, CF00, CF50, The installation of this product should be carried out by a qualified pool technician, following the installation instructions provided in this manual.

More information

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position. 027R9782 Instructions Control Solution ICF 20-4, ICF 25-4, ICF 32-4. ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 with ICM ICM 027R9782

More information

776 Cryogenic Safety Valve

776 Cryogenic Safety Valve 776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant

More information

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG A C E D SB 8551.3 Model 1800 PFM Series Regulator For Constant Precise Fixed Factor Measurement From 0.5 to 30 G AMC Quality System QMI is Accredited by: C R E D I T ISO 900 Registered R E ANSI RAB G I

More information

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating

More information

Eaton Filtration, LLC

Eaton Filtration, LLC Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual

More information