On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.
|
|
- Stephany Mathews
- 5 years ago
- Views:
Transcription
1 SPEEDMAN VARIABLE SPEED PUMP SET VARIABLE SPEED PUMP SET PRODUCT DESCRIPTION Variable speed / constant pressure system consisting of a Davey VM vertical multistage pump with Speedman controller, VSD unit, pressure transducer, 24 litre pressure tank, inlet and discharge manifolds, isolating and non-return valves, all mounted on a stainless steel base. APPLICATIONS Pumping of clean, non-aggressive liquids, free of fibres in suspension, suitable for applications such as:- Agriculture & Turf Watering Commercial & Industrial Processes Pressure Boosting in Commercial buildings Water Supply Rural & Industrial Commercial High Pressure Washing & Water Treatment FEATURES & BENEFITS OPERATING LIMITS Provides constant pressure via variable speed control for single pumps up to 3kW. Simple dial adjustable set point to allow the operator to adjust the set point to suit individual applications. Incorporates high & low pressure shutdown protection with adjustable delay timers. High & low pressure settings automatically track set point changes for ease of adjustment. Automatic sensing of no flow condition via pressure boosting to protect the pump. LED display shows pump operation, status and fault conditions. Indicators include power on, pump running, VSD fault, high pressure and low pressure faults and no flow testing. On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor. Programmable output relays for external communications of fault conditions, lag pump or jockey pump operation. Capacities to Pressure heads to 11m 3 /hr (1833lpm) 16m Maximum suction pressure Refer pg 2 Liquid temperature range Power supply single phase Power supply three phase Pump Rotation o to +7 o C up to 2.2kW up to 3kW Anti-clockwise (top view)
2 MAXIMUM INLET PRESSURE MATERIALS OF CONSTRUCTION Model VM3-8 VM3-12 & above Up to VM5-1 VM5-12 & above Up to VM1-6 VM1-8 & above VM16-2 and VM16-3 VM16-4 & above VM32-2A VM32-3 to VM32-4 VM32-6 to VM32-1 VM32-12 VM65-2A VM65-2 to VM65-3 VM65-4A and VM65-5 Up to VM9-3A VM9-3 & above Maximum Inlet Pressure 6 bar 1 bar 1 bar 15 bar 6 bar 1 bar 6 bar 1 bar 3 bar 4 bar 1 bar 15 bar 4 bar 1 bar 15 bar 1 bar 15 bar PART Pump base Suction & discharge casing Motor support lantern Impellers Stages (casing) Outside sleeve Pump shaft Intermediate bearing Mechanical seal Orings (casing) Plugs (drainage & priming) Impeller neck rings MATERIAL Cast iron 34 stainless steel Cast iron 34 stainless steel 34 stainless steel 34 stainless steel 316L stainless steel Tungsten carbide Silicon carbide/carbon/epdm EPDM 316L stainless steel Teflon * Special version with 316L stainless steel & viton orings on request NOTE: 34 stainless steel, (Z6 CN 18.9) and 316L stainless steel (Z2 CND 17.12) are recommended materials that are highly resistant to corrosion. Suitable for pumping clean, clear non-viscous liquids, containing no fibres or solids. Maximum sand/silica concentration 4 g/m 3. MAXIMUM WORKING PRESSURE Model Curve Number Up to VM Up to VM Up to VM VM Up to VM VM Up to VM VM VM65 range 1 Up to VM9-4 1 The following figure shows the limitation of working pressure and temperature of VM pumps. Pumps should only be operated within the region shown by the curves below. P(bar) T( o C) 1 IDENTIFICATION OF THE PUMP SET SMAN 32-2A/3 WM Control Box Blank = Stand mount WM = Wall mount Motor fitted Blank = Single phase /3 = Three phase Impeller variation (A = manufacturer s turndown) Number of stages Nominal capacity of VM Pump at BEP in m 3 /hr Speedman Pump Set ALTITUDE & TEMPERATURE VS LOSS OF HEAD Guide only. Altitude and temperature losses are added. Altitude Loss of head m m 5m.6m 1m 1.15m 15m 1.7m m 2.m 25m 2.65m 3m 3.m Temperature Loss of head C.m 3 C.4m 4 C.7m 5 C 1.m 6 C 1.9m 7 C 3.1m 8 C 4.7m 9 C 7.1m 1 C 1.3m
3 HYDRAULIC PERFORMANCE VM3, 2 POLE 5Hz VM5, 2 POLE 5Hz VM3-23 VM3-19 VM3-15 VM3-12 VM3-8 VM3 5Hz Q(m 3 /hr) Q(m 3 /hr) VM5-16 VM5-14 VM5-12 VM5-1 VM5-8 VM5-5 VM5 5Hz Q(l/s) Q(l/s) VM1, 2 POLE 5Hz VM16, 2 POLE 5Hz Q(m 3 /hr) VM1-14 VM1-12 VM1-1 VM1-8 VM1-6 VM1-4 VM1 5Hz VM16-11 VM16-8 VM16-6 VM16-4 VM16-3 VM16-2 VM16 5Hz Q(m 3 /hr) Q(l/s) Q(l/s) NOTE: CURVE TOLERANCE IN CONFORMITY WITH ISO996 APPENDIX A.
4 HYDRAULIC PERFORMANCE VM32, 2 POLE 5Hz VM65, 2 POLE 5Hz VM32-8 VM32 5Hz VM65-5 VM65 5Hz 14 1 VM VM65-4A 1. 1 VM VM VM32-4 VM VM65-3A VM VM32-2A.4 4 VM65-2A.2. Q(m 3 /hr) Q(m 3 /hr) Q(l/s) Q(l/s) VM9, 2 POLE 5Hz PRESSURE BOOSTING VM9-4 VM9-4A VM9-3 VM9 5Hz The Speedman pumpset uses pressure boosting to determine when there is flow in the system. Periodically, it will momentarily boost the pressure and then watch for the pressure to decay back to the set point. If there is no decay within a set time period the system deems there is no-flow and shuts down. OPTIONS Boost frequency setting: 4, 8, 1 or 16 seconds Boost pressure setting: 3%, 6%, 12% and 18%.8 8 VM9-3A Boost decay test time: 2, 1, 3 and 6 seconds VM Q(m 3 /hr) Q(l/s) NOTE: CURVE TOLERANCE IN CONFORMITY WITH ISO996 APPENDIX A.
5 DIMENSIONS Pump Model Motor kw Height mm Length mm Width mm Pipe DN mm 3-8 SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN SMAN A SMAN32-2A SMAN SMAN SMAN SMAN SMAN A SMAN65-2A (Table E) 65-2 SMAN (Table E) 65-3A SMAN65-3A (Table E) 65-3 SMAN (Table E) 65-4A SMAN65-4A (Table E) 65-5 SMAN (Table E) 9-2 SMAN (Table E) 9-3A SMAN9-3A (Table E) 9-3 SMAN (Table E) 9-4A SMAN9-4A (Table E) 9-4 SMAN (Table E)
6 VM3, 5, 1, 16 and 32 VM3,5 = Ø32 VM1 = Ø4 VM16 = Ø5 VM32 = Ø65 VM3,5,1 = 1153 VM16,32 = 117 Ø VM3,5,1 = 46 VM16,32 = 43 VM3,5,1 = 51 VM16,32 = 48 VM3,5 = 675 VM1 = 74 VM16,32 = 775 VM3,5 = 128 VM1 = 133 VM16 = 16 VM32 = 175 VM65 and VM Specific dimensions for each model available on request
7 MOTOR TECHNICAL SPECIFICATIONS Motor 1 Phase Frame IP Rating FLC 24 V Start/LRC Ratio RPM Eff % Drive End Bearings Non-D/End.75 8 V18 IP ZZ 64-ZZ V18 IP ZZ 64-ZZ V18 IP ZZ 65-ZZ V18 IP ZZ 65-ZZ Motor 3 Phase Frame IP Rating FLC 415 V Start/LRC Ratio RPM Eff % Drive End Bearings Non-D/End.75 8 V18 IP ZZ 64-ZZ V18 IP ZZ 64-ZZ V18 IP ZZC3 65-ZZC V18 IP ZZC3 65-ZZC V18 IP ZZC3 65-ZZC V18* IP S 636-S V1* IP B 638ZZC V1* IP B 638ZZC V1* IP B 639ZZC V1* IP B 639ZZC V1* IP B 639ZZC V1* IP V1* IP *Special motor bearings fitted for thrust management.
8 Davey Water Products Pty Ltd Member of the GUD Group ABN AUSTRALIA Head Office and Manufacturing 6 Lakeview Drive, Scoresby, Australia 3179 Ph: Fax: Website: davey.com.au NEW ZEALAND 7 Rockridge Avenue, Penrose, Auckland 161 Ph: Fax: sales@daveynz.co.nz Website: daveynz.co.nz REST OF WORLD 6 Lakeview Drive, Scoresby, Australia 3179 Ph: Fax: export@davey.com.au Website: davey.com.au H/O & MFG SCORESBY Quality ISO 91 H/O & MFG SCORESBY Environment ISO 141 Customer Service Centre Ph: Fax: sales@davey.com.au Customer Service Centre Ph: This literature is not a complete guide to product usage. Further information is available from your Davey dealer, Davey Customer Service Centre and from the relevant product Installation and Operating Instructions. This data sheet must be read in conjunction with the relevant product Installation and Operating Instructions and all applicable statutory requirements. Product specifications may change without notice. Davey is a registered trademark of Davey Water Products Pty Ltd. Davey Water Products Pty Ltd 11. DPM251-1/5K/811/IPM supersedes DPM251a/311/WEB & DPM251/5K/18/IPM
APPLICATIONS. Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors.
OPERATING RANGES Flow rates of up to: 3 m 3 /h Manometric heads of up to: Max. delivery pressure: Max. intake pressure: Temperature range: 35 9 m CL 1 bar bar - 15 to +11 C* Max. ambient temperature: +
More informationDEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company
C.R.I. PUMPS DEEP WELL SUBMERSIBLE PUMPS EVERGREEN SERIES - 5Hz An ISO 91 & 141 Company Submersible Pumps C.R.I. Submersible Pumps are the products of the expertise gained from over four decades of experience,
More informationMultiple Pressure Booster Systems With Variable Speed Controller Type BL
Multiple Pressure Booster Systems With Variable Speed Controller Type BL General Characteristics - Single or multistage pumps - Horizontal or vertical mounting - Total head 30m ~ 250m - Material construction:
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationSTAINLESS STEEL GRAND SERIES
STAINLE STEEL GRAND SERIES STAINLE STEEL GRAND SERIES DEEPWELL SUBMERSIBLE PUMPS STAINLE STEEL - GRAND SERIES C.R.I. Always equips itself in advance to face the exponentially growing technological challenges
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More information50Hz. water solutions. O SerieS DGO DRO
Hz water solutions O SerieS DGO DRO D a t a b o o k l e t EN water solutions O SerieS DGO DRO Hz D a t a b o o k l e t O SERIES O Series General characteristics AISI stainless steel lifting and carrying
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More information60HZ XIANDAI PUMP. CDL/CDLF Vertical Multistage Pump ZHEJIANG XIANDAI PUMP CO.,LTD. ZHEJIANG XIANDAI PUMP CO.,LTD.
TECNICAL DATA INCLUDED IN TIS BROCURE MAY BE CANGE FROM TIME TO TIME DUE TO TE PRODUCT IMPROVEMENTS UNDERTAKES BY TE MANUFACTURER. TE COMPANY RESERVES TE UNCONDITIONAL RIGTS TO IMPLEMENT SUC CANGES WITOUT
More informationSIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
More informationMZT PUMPI PUMP YOUR WAY TO SUCCESS MULTISTAGE CENTRIFUGAL PUMPS - MS,DMS,MSTD,MSS
UM YOUR WAY TO SUCCESS MULTISTAGE CENTRIFUGAL UMS - MS,DMS,MSTD,MSS Catalog 9 CONTENT GENERAL DATA.................................................... 3 Description.......................................................
More informationLiquid ring compressors
Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and
More informationLiquid ring vacuum pumps single-stage
Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement
More informationPage - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302
CONTENTS. Page - SPECIFICATIONS 200 SPECIFICATION 200 SELECTION CHART PFC 201 SELECTION CHART 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 2 204 PERFORMANCE CURVE 3 205 PERFORMANCE CURVE
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated
More informationTPR Series. Vertical Multistage Centrifugal Pumps. 60Hz
TPR Series Vertical Multistage Centrifugal Pumps z Contents General Data Performance Range Product Range Applications Pump Motor Operating Conditions TPR Materials TPR(S)(N) Materials Type Key Operating
More informationEtanorm V Type Series Booklet
Vertical Low-pressure Pump Etanorm V Type Series Booklet Legal information/copyright Type Series Booklet Etanorm V All rights reserved. The contents provided herein must neither be distributed, copied,
More informationTwo-port valves, male threaded, PN25
4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...
More informationDean Pump Self-Priming Chemical Process Pumps
Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL
More informationMonsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.
Monsoon3V+ Multiple Pump VFD Control System Please pass these instructions on to the operator of this equipment. INTRODUCTION MONSOON 3V+ Pump Controller The MONSOON 3V+ pump control system is a fully
More informationUCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES
OPERATING LIMITS Flow rates up to: 24 m 3 /h Head up to: 62 m Maximum immersion depth: 12.5 m Max. particle size: Ø 5 to 8* ND discharge port: 8/1 mm IP : 68 *depending on model SUBMERSIBLE PUMPS Lifting
More informationAxial piston pumps type PVC
www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationAxial piston pumps type PVC
www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low
More informationGRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz
GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical
More informationLiquid ring compressor
Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of
More informationCALEFFI. Ball zone valves. series /03 GB
all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the
More informationSubmersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series
Submersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series Submersible pumps for clean and slightly dirty water manufactured in AISI 304 stainless steel. Head up to 20 metres,
More information2-port seat valves PN25 with externally threaded connections
4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with
More informationGMD20..NL, GMD30..NL* GHV20..NL, GHV30..NL* GHV40..NL, GTKS20..NL* Series
GMD20..NL, GMD30..NL* GHV20..NL, GHV30..NL* GHV40..NL, GTKS20..NL* Series Fixed and Variable speed Booster sets Maximum operating pressure 16 bar. Flow rates up to 56 m 3 /h 50 Hz * FOR NEDERLAND MARKET
More informationRemotely-installed Hydraulic Module
Remotely-installed Hydraulic Module HDM 1.1-2.2 Single or twin pump ACC-PRC001E-GB Table of Contents Application Considerations Unit sizing...4 Unit placement... 4 Minimum water volume... 4 Selection Procedure...5
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design LEM 26, LEM 51 Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated
More informationDavey Pool & Spa New Products Launch
Davey Pool & Spa New Products Launch New EcoMatic Salt Water Chlorinator > New EcoMatic models: DEM14C, DEM20C & DEM26C > Replaces the old EcoSalt models: MES13C, MES20C & MES26C > Digital dual timers
More informationPressure Independent Control Series
Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single
More informationGoulds 3296 EZMAG. Chemical Process Pump
Goulds 3296 EZMAG Chemical Process Pump 3296 EZMAG Chemical Process Pump Capacities to 700 gpm (160 m3/h) Heads to 620 ft (189 m) Temperatures to 535 F (280 C) Pressures to 275 PSIG Performance Features
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION
ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050
More informationDisplacement 12, , Maximum flow rate (at 1450 rpm) bar.
00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment
More informationMXV. Vertical Multi-Stage In-Line Pumps. Construction. Applications
MXV Construction Vertical ulti-stage pups with suction and delivery connections of the sae diaeter and arranged along the sae axis (in-line). Corrosion-resistant bearing sleeves lubricated by the puped
More information2-Port Seat Valves with Flange, PN 16
4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic
More informationCOMPACT Booster Sets Data Book 50Hz
Japanese Technology since 1912 COMPACT Booster Sets Data Book 50Hz 50Hz CONTENTS INDEX GP-GPE Page CONTENTS INDEX 2 DEFINITION AND USE OF PRESSURISATION UNITS 101 TYPICAL APPLICATIONS 101 PRINCIPLE OF
More informationGROUTEC SCOTT VICKERS. Grouting Equipment
GROUTEC SCOTT VICKERS Grouting Equipment SCOTT VICKERS manufacturers a range of cement and chemical grouting equipment including:- PUMPS - The Cement Grout Pumps are all diaphragm-type. These diaphragms,
More informationTECHNICAL ACCESSORIES
A.R.I. VALVES S-050P AIR PLASTIC RELEASE 16 BAR Automatic Component A.R.I patent, Rolling Seal Mechanism: Dramatically reduces the possibility of obstruction by debris. Discharges high air flow rates upto
More informationE.2 Series. High efficiency circulator. Technical overview
E.2 Series High efficiency Technical File No:.165 Date: june 05, 2017 Supersedes:.165 Date: october 08, 2015 contents Motor data 4 Technical data 4 Materials of construction 4 Dimensions and weights 5
More informationDosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &
C hemical Dosing & Controllers Granudos Chemical Dosing & Controllers Controllers Chemical Storage Granudos Granudos 10-CPR Touch Granudos 10-CPR Touch swimming pool disinfection system using IQ Granu-Chlor
More informationEcoSpa Salt Water Spa Sanitisation System
EcoSpa Salt Water Spa Sanitisation System Installation and Operating Instructions AUSTRALIA Davey Support Centre 6 Lakeview Drive, Scoresby, Australia 3179 Ph: 1300 367 866 Fax: 1300 369 119 Website: davey.com.au
More informationExpansion Vessels for Potable Installations
4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm
More informationAir Eliminator Series
Air Eliminator Series Air Separation Equipment FILE NO: 9-1 DATE: August 2010 SUPERSEDES: 9-1 DATE: January 2009 Air Eliminator Series Air Separation Equipment Modern sealed heating and cooling systems
More informationTHIS DOCUMENT SHOULD STAY WITH THE PUMP UNIT AT ALL TIMES!
VERDERMAG Global PC 160L/M/H Maintenance Manual THIS DOCUMENT SHOULD STAY WITH THE PUMP UNIT AT ALL TIMES! TO BE READ IN CONJUNCTION WITH MAINTENACE MANUAL Page 1 of 16 Index 1.0 DOCUMENTATION 1.1 Type
More informationRP series Rotor Pumps
ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting
More informationAdvanced Pump Control for Irrigation Applications
Advanced Pump Control for Irrigation Applications Paul Nistler VFD Applications Engineer And Julian Atchia Director of Research and Development SJE Rhombus 22650 County Hwy 6 Detroit Lakes MN 56502 Executive
More informationGS20-GS21-GS30 Series
GS-GS1-GS3 Series Fixed-speed pressure booster sets with Horizontal Centrifugal electric pumps FH and SH series Hz WEB 1-1 CONTENTS General introduction... Choice and selection... 13 GS.../FH Series...13
More informationMXV-E. Variable Speed Multi-Stage Vertical Pumps (max 2900 rpm)
Variable Speed Multi-Stage Vertical Pups (ax 9 rp) Construction Vertical ulti-stage pups with suction and delivery connections of the sae diaeter and arranged along the sae axis (in-line). Corrosion-resistant
More informationProportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
More informationHERZ-Motorised flow controler
HERZ-Motorised flow controler Control and regulating valve Data sheet 46, Issue 214 Dimensions in mm 4 close dimension 9,35 M DN G H1 H2 H2 + Actuator B1 B2 1 2 M 1 46 11 15 3/4 G 66 59 73 134 49 63 48
More informationLiquid ring compressors
Liquid ring compressors KPH 95652 Compression pressures: 6 to 12 bar(g) Suction volume flow: 2960 to 3600 m³/h 78 to 174 psig 1742 to 2119 cfm DESIGN TYPE SIHI liquid ring compressors are displacement
More informationDAVEY for the pool & spa
for the pool & spa for the pool & spa Davey s promise is simple to provide dependable, innovative water solutions when and where people need them, supported by the best service and advice. Davey Water
More informationMOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL
MOYNO Section: ACCESSORIES Page: 1 of 8 Date: May 1, 1998 SERVICE MANUAL FLUID DETECTION CONTROL GENERAL The Moyno Fluid Detection Control prevents unnecessary loss of production time or repair costs to
More informationSINGLE VALVE WITH LOW-FLOW BYPASS
CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex
More information3-port seat valves with externally threaded connection, PN 16
4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More information2-port and 3-port valves PN 16
OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port
More information400V 50Hz. Tsurumi TRN. Submersible aerator. Auto-suction submersible aerator for communal and industrial waste water clearance and treatment.
Tsurumi TRN 400V Hz Submersible aerator Auto-suction submersible aerator for communal and industrial waste water clearance and treatment. TRN-submersible aerator The Tsurumi TRN-submersible aerator is
More informationELADOS EDP L Diaphragm Metering Pump Type
ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST
More informationAxial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request
www.atos.com Table TA60obs/E Axial piston pumps type PVPY- (-R, -) variable displacement, with mechanical controls obsolete components - availability on request PVPY are variable displacement axial piston
More informationInflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer
Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump
More informationScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m
ScanFoam Cleaning Equipment ApS w w w. s c a n f o a m. c o m Units List of Equipment 2015-06A ScanFoam ApS Skanderborg Denmark Phone: +45 86 57 25 99 Fax: +45 86 57 20 86 E-mail: anders.christensen@scanfoam.com
More informationHydro Dome GRUNDFOS INSTRUCTIONS
GRUNDFOS INSTRUCTIONS Hydro Dome Installation and operating instructions Montage- und Betriebsanleitung Notice d installation et d entretien Istruzioni di installazione e funzionamento Instrucciones de
More informationsolids Rotary Valves Type ZRS
Discharge and metering rotary valve, for discharge of silos and/or feed into pressure or vacuum conveying pipelines ; even for dust explosion hazardous products Advantages: Sturdy and less wear Cost-effective
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationNikuni KTM Series Pumps
Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM2F- (Cast Iron/SS material fittings) Date : Doc. No. : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku,
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX HHV-E Vortex Driven Regulator HYDROVEX HHV-E VORTEX DRIVEN REGULATOR APPLICATION The hydro electronic HYDROVEX HHV driven regulator, type E is specially designed for
More informationDifferential pressure controller (PN 16) AHP - return mounting, adjustable setting
Data sheet Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Description DN 15-40 DN 50 DN 65-100 AHP is a self-acting differential pressure controller primarily for use
More informationSafety and Shut-off Block SAF/DSV
1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES
1. INTRODUCTION The AVK knife gate valve is a unique, patented, bi-directional on-off valve that ensures a bubble-tight shut off. The valve is available with body of ductile iron and seat of nitrile, viton,
More informationBERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
More informationATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1
ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar
More informationInnovDos Foam proportioning system
InnovDos Lorrie 9 NL - 1724 BL Oudkarspel T: +31 88 9112 112 F: +31 88 9112 119 info@innovfoam.com www.innovfoam.com 1 1. General Information System Composition The InnovDos is made up of two main components
More informationPilot valves for pilot operated servo valves
Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)
More informationLP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand
Proceedings World Geothermal Congress 2010 Bali, Indonesia, 25-29 April 2010 LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal
More informationInnoVfoam B.V. InnovDos Foam Proportioning System
1724 BL Oudkarspel F. +31 (0)88 9112 119 info@innovfoam.com 1 1. GENERAL INFORMATION SYSTEM COMPOSITION The InnovDos system is made up of two main components (see flow schedule on page 4) that can be integrated
More informationDataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified
DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument
More informationSABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
More informationKIT. Small Automatic Water Boosters KIT MODELS
KIT Small Automatic Water Boosters The electronic controller KIT orders the automatic start and stop of the water pump when opening or closing any tap or valve in the installation. There are four main
More informationPRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)
PRODUCTS CATALOGUE 2017 / 2018 10156 Torino - Strada Settimo 388/15 Tel (+39) 011.223.68.42 /43 Fax (+39) 011.223.67.67 info@ebarbero.com www.ebarbero.com CATALOGO INDEX PRODOTTI 2017 / 2018 Pumps for
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationTurbo Blowers. Combustion Excellence Since Features. Benefits
Turbo Blowers Features Integral molded scroll design Turbine bladed impeller Steel inlet guard Precisely balanced impellers eliminate vibration Complete line of available accessories for adapting to any
More informationNikuni KTM Series Pumps
Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM2N- (SS34 Material) Doc. No. : Date : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku, Kawasaki-Shi,
More informationTo plot the following performance characteristics; A pump is a device, which lifts water from a lower level to a higher
LABORATORY MANUAL ON RECIPROCATING PUMP TEST RIG Prepared By Prof. (Dr.) M. K. Roul Professor and Principal Department of Mechanical Engineering Gandhi Institute for Technological Advancement (GITA), Bhubaneswar-752054
More information50 Hz. GS20-GS21-GS30 Series. FIXED-SPEED PRESSURE BOOSTER SETS WITH HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS FH and SH SERIES. Cod.
Hz GS-GS1-GS3 Series FIXED-SPEED PRESSURE BOOSTER SETS WITH HORIZONTAL CENTRIFUGAL ELECTRIC PUMPS FH and SH SERIES Cod. 19191 Rev ev.b.b Ed./1 CONTENTS General introduction... Choice and selection...
More informationCOMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x
Electrical Installation Requirements Care should be taken to separate the power and signal cables to prevent electrical interference and possible damage due to inadvertent connection. SUPPLY E L N LN2
More informationDESIGN ENVELOPE 6800 G 1 DUTY PUMP
DESIGN ENVELOPE 68 G 1 DUTY PUMP AND 1 STANDBY, DOMESTIC WATER BOOSTER WIT STANDBY N122s N192s SUBMITTAL File No: 1.615 Date: june 27, 217 Supersedes: new Date: new Job: Representative: Engineer: Contractor:
More informationTechnical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3
Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling
More informationGEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM
Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 PM GEA PUMPS TABE OF CONTENTS DESCIPTION......................................................................................................................
More information