1 AIR LINE PURIFIERS FOR BREATHING EQUIPMENT AP-C RADEX INSTRUCTION MANUAL & PARTS
2 introduction CANABLAST BREATHING EQUIPMENT PURIFIER CAN BE USED IN CONBINATION WITH WITH OTHER SAFEGUARDS TO SUPPLY CLEANER AIR TO AIRLINE RESPIRATORS AND MANY PNEUMATIC TOOLS AND SYSTEMS. CANABLAST PURIFIERS ARE DESIGNED TO REMOVE 98 % OF PARTICLES DOWN TO 0. MICRON SIZE, BUT WILL NOT REMOVE CARBON MONOXIDE AND OTHER GASES FROM AIRLINE. SET UP 1. LOCATION : Select a flat, stable location to place the purifier. If the purifier will be used in a permanent location or if stabilty is a problem, the legs can be mounted on a flat surface.. HOOK-UP : Connect the piping coming from the compressor to the air inlet ( 1 NPT FEM ). Connect the airline hose that leads to your respirator or pneumatic cool to the purifier outlet. Tighten the connections to prevent leaks. IMPORTANT- WHEN USING A RESPIRATOR, DO NOT CONNECT THE PURIFIER ON ANY AIR SOURCE UNLESS YOU ARE CERTAIN IT CONTAINS BREATHABLE AIR. O P E R At I O N 1. AIR REQUIREMENTS a) Air source The law requires that when oil Iubrificated compressor are use as sources of breathing air,you must equip them with high temperature alarm or carbon monoxide monitors/alarm or both. If only a high temperature alarm is used, you must frequently test the compressor air for carbone monoxide to ensure it meets the Grade D requirements specified below. The law also requires that breathing air hose couplings be incompatible with ourlets for other gas systems in order to prevent accidental connection of a supplied air respirator to non-breathable gases or pure oxygen. b) Quality of breathing air Supplied breathing air passing through this purifier to respirator must meet at least the requirements for Type 1 gaseous air as described in the U. S. Compressed Gas Commodity Specification G.1 (Grade D or higher) as specified the in american federal law 0 CFR, Part 11, Subpart J, (b). The Canablast airline purifier does not remove carbon monoxide and other toxic gases from the air being supplied. The requirements for Grade D breathable air include : Oxygen % Carbon Monoxide 0 ppm max. Carbon Dioxyde C ppm max. Hydrocarbons (condensed) mg/m max. non-toxics contaminants at levels which would make the air unsafe to breathe APC & Radex - Instruction Manual & Parts
3 O P E R At I O N ( cont d ) c) Air Pressure The air pressure at purifier inlet should not exceed 100 psi. Air will be released by pressure relief valve when pressure within the purifier exceeds 1 psi. Air discharging from purifier can be controlled to meet air pressure requirements by using the pressure regulator adjustment knob. Refer to your respirator or pneumatic tool instruction manual to find the appropriate air pressure required for correct use of the equipment. d) Temperature Air supplied to purifier should not exceed 10 F (0 C). T herefore, do not comlect the purifier directly to compressor exhaust manifold.. CORRECT OPERATION PROCEDURES : a) Keep the drain valve slightly open to ensure a constant draining. This will keep water and oil from accumulating inside the tank, damaging the cartridge. b) Tighten the fasteners which secure the head of the purifier tank. Over time, the fasteners may loosen which could cause a leak in the air system. Standard tightness for fasteners of this type (/8, grade ) is 1 ft./lbs. warning This purifier does not remove carbon monoxyde and other toxic gases. warning USE ONLY CANABLAST FILTER CARTRIDGES AS REPLACEMENTS THESE PURIFIERS ARE DESIGNED TO use ONLY CANABLAST FILTER CARTRIDGES APC & Radex - Instruction Manual & Parts
4 C A R T R I D G E R E P L AC E M E N T Replaceable filter cartridge -stage operation Cartridges effectively trap and remove 98% of impurities down to 0. micron in size, with little pressure Ioss. The compressor supplies air enters at inlet fitting (A) filters up throught filter materials and exits into hose connected to airline filter (B). All stages work in sequence to trap and hold water, oil particulates, odors and organic vapors so that cleailer air is delivered to workers or equipment. 1. Water is removed by vortex action of air in outer cylinder. B A. Carded cotton removes particles.. Activated alumina absorbs oil and moisture.. Felt material removes particulates.. Activated charcoal removes odors and moisture.. Carded cotton removes more particulates. Respiratory felt at final stage operates at 98% efficiency down to 0. micron size. The frequency of filter cartridge replacement depends on the condition of the particular air system in which the purifier is installed. However, the filter cartridge should be replaced immediately if : a) The user smells or tas tes contaminants in the air being supplied to an air supplied respirator, or : b) There is a large pressure drop in the system, even though the compressor and other components appear to be operating correctly. CORRECTIVE ACTION 1. Shut off air supply and drain filter. Disconnect the purifier from air source before servicing.. Remplace the cartridge : a) Separate the purifier head from the tank by removing the fasteners. b) After removing the cartridge, clean inside of the tank to remove any remaining contaminants. c) Insert a new CANABLAST filter cartridge. Tighten the fasteners across from each other and not in a circular sequence. this will help prevent warping of the filter head.. Record the date the filter was replaced on the label attached to the airline filter tank. You can developa filter replacement schedule by monitoring the frequency with which the cartridge needs to be changed.. If conditions are not improved, do not use the filter until appropriate corrective measures have been taken APC & Radex - Instruction Manual & Parts
5 A P - c : exploded v ie w & Part S # STOCK DESCRIPTION 1 10 Complete APC regulator 009 Complete APC purifier Cover Manometer 1/ Pressure regulator 10 Gasket Cover Gasket Drain valve Safety valve APC & Radex - Instruction Manual & Parts
6 R A D E X : exploded v ie w 1 OUTLET OUTLET APC & Radex - Instruction Manual & Parts
7 R A D E X : Part S # STOCK DESCRIPTION A 000 RADEX FILTER ASSEMBLY QUICK RELEASE COUPLER, FEMALE THREAD, /8 00 TEE, BRASS, /8 00 CAP, BRASS, /8 00 PRESSURE REGULATOR, LESS GAUGE 00 PRESSURE GAUGE 00 VALVE, PRESS RELIEF, 1 PSI, ¼ NPT 00 HEX NIPPLE, BRASS, / FILTER LID O - RING, SET OF FILTER CARTRIDGE, FLANGED BOLT, NUT, WASHER, SET OF 1 01 FILTER BODY 1 01 DRAIN TAP, BRASS, ¼ NPT 1 01 BASE MOUNT 1 01 AUTO DRAIN UNIT, ¼ NPT 1 01 MICRO MIST FILTER ½ ASSEMBLY 1 01 REDUCING NIPPLE, BRASS, 1 x ½ ELBOW, BRASS, ¼ SIX OUTLET FILTER LID 0 00 OUTLET MANIFOLD 1 01 COUPLERS 0 PRESSURE GAUGE 0 SUPER HIGH FLOW REGULATOR 0 CONNECTOR, 1 NPT APC & Radex - Instruction Manual & Parts
8 WA R R A N T Y I N F O R M AT I O N / T E C H N I C A L A S S I S TA N C E For more information, prices or technical assistance, contact your local IST distributor or call / fax our Consumer Information Numbers : Fax : Or visit us at : 10 Industriel Blvd. Laval, Quebec HL H1 Canada Toll free T F Info@istblast.com
AIRLINE-SERIES HELMET AIR FILTER
OWNER S MANUAL AIRLINE-SERIES HELMET AIR FILTER IMPORTANT WARNING FOR SAFER BLAST CLEANING 1. Use protective equipment: Abrasive-resistant clothing, safety shoes, leather gloves, ear protection, CE-approved
More informationADVANCED AIRLINE FILTER INSTRUCTION MANUAL
ADVANCED AIRLINE FILTER INSTRUCTION MANUAL CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference. INTRODUCTION 3!WARNINGS! 5 BASEMOUNT ASSEMBLY 6
More informationINTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9
Instruction Manual rode~ AIRLINE F I LTER INTRODUCTION... 3 WARNINGS I 4-5 ASSEMBLY... 6,7,8 OPERATION I... 9 MAINTENANCE I Ill 1 0,11 PARTS LIST I 12 RPB 62/2 a rode~ A I R L I N E F I L T E R..: INTRODUCTION
More informationSERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL
www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.
More informationSERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL
Product Manual MST Portable Air Filtration System SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the
More informationBREATHABLE AIR SYSTEMS
BREATHABLE AIR SYSTEMS The airline respirator Series offer comfortable, reliable respiratory protection for abrasive blasters and painters. Our systems are NIOSH approved as Type C or CE Continuous Flow
More informationSERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL
More informationSERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL
More informationSERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL
1 SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2 GENERAL
More information3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.
3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems Work in a World of Comfort 3M TM Versaflo TM AP-600 Series Air Filtration Panels (AFP)
More informationSERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL
SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 5/08 2 GENERAL
More informationSERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 6/08 2 GENERAL
More informationPRODUCT OPERATING MANUAL
PRODUCT OPERATING MANUAL PANBLAST TM VISIFLO RESPIRATOR AIRLINE FILTERS Manual Number: ZVP PC 0084 01 Pressure Equipment Directive 97/23/EC SECTION 1. GENERAL INFORMATION 2. INTRODUCTION 3. PREPARATION
More informationMODEL RP050BMST RESPIRATORY PROTECTOR MANUAL
MODEL RP050BMST RESPIRATORY PROTECTOR MANUAL ****************************************************************************** WARNING: Do not attempt to operate this equipment without first reading and understanding
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll
More informationPremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION
DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY
More informationMODEL RP200C(_)-S1 RESPIRATORY PROTECTOR MANUAL
MODEL RP200C(_)-S1 RESPIRATORY PROTECTOR MANUAL ****************************************************************************** WARNING: Do not attempt to operate this equipment without first reading and
More informationOperating Manual. Model BAC-30RT30/BAC-30DC
Model BAC-30RT30/BAC-30DC Manual No. BAC012 (Rev 1 October 2002) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100
More informationMODEL RP050BMST-S1 RESPIRATORY PROTECTOR MANUAL
MODEL RP050BMST-S1 RESPIRATORY PROTECTOR MANUAL ******************************************************************************************** WARNING: Do not attempt to operate this equipment without first
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationATD LB PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off
More informationB-Series. breathing air systems flow capacity: scfm
B-Series breathing air systems flow capacity: 14-486 scfm B 1 B-Series breathing air systems flow capacity: 14-486 scfm B 1 Leading edge technology and more than 100 years of experience nano-purification
More informationADP3CA Free-Air Pump User Manual
ADP3CA Free-Air Pump User Manual Read all instructions before using this PUMP Table of Contents GENERAL INFORMATION... 1, 2 WARNINGS... 3 PUMP COMPONENTS... 4 BREATHING AIR REQUIREMENTS... 4 ASSEMBLY AND
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: (507)
More informationaccidents which arise due to non-observance of these instructions and the safety information herein.
3 GALLON PANCAKE COMPRESSOR Model: 50959 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationA Pocket Guide to Air-Line Systems. Visit: Or for Sales & Service.
A Pocket Guide to Air-Line Systems Introduction Type C Supplied-Air Respirators, more commonly referred to as air-line respirators, are designed to provide long-duration respiratory protection. They generally
More informationImportant: Keep these instructions for reference.
V-Series Air Control Devices User Instructions for 3M TM Vortex Cooling Assembly V-100 and V-100SS (Stainless Steel), 3M TM Vortemp TM Heating Assembly V-200 and V-200SS (Stainless Steel), 3M TM Air Regulating
More informationSPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
More informationAdvantage 4000 Abrasi-Blast Respirator
Advantage 4000 Abrasi-Blast Respirator Features Constant Flow Air-Line Respirator and Constant Flow Duo-Flo Respirator options Choice of shoulder length or waist length hoods to meet various blasting applications
More informationBREATHING AIR PURIFIER
INSTRUCTION MANUAL BREATHING AIR PURIFIER Model: PBA-12 FORM NO.: 3227497 REVISION: 02/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. Contents GENERAL SAFETY INFORMATION...
More informationINSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
More informationexceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)
exceeds global breathing air quality standards B 1 breathing air systems flow capacity: 6-486 scfm flow capacity: 8-1500 scfm (13-2550 Nm 3 /hr) breathing air systems flow capacity: 6-486 scfm B 1 Leading
More informationA Pocket Guide to Air-Line Systems
A Pocket Guide to Air-Line Systems Introduction Type-C supplied-air respirators, more commonly referred to as air-line respirators, are designed to pro vide long-duration respiratory pro tec tion. These
More informationList of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6
Úprava stlačeného vzduchu EWO VMA List of Contents System description Individual Units Pre-Filters 3 Micro-Filters 4 Activated-Charcoal-Filters 5 Combinations 6 Accessories and Main spare parts 6 Service
More informationADP20 Free-Air P u m p
The Human Side of Safety. Since 1898. ADP20 Free-Air P u m p Instruction Manual READ ALL INSTRUCTIONS BEFORE USING THIS PUMP C O N T E N TS GENERAL INFORMATION... 1 WARNINGS... 3, 4 PUMP COMPONENTS...
More informationINSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL
INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL 8059601 To be used with MST Model 8050501 Ambient Air Pump 7/12/05 2 TABLE OF CONTENTS GENERAL INFORMATION... 3 WARNING...4,5 UNPACKING AND AFTERCOOLER ASSEMBLY
More informationCompressed Airline Breathing Apparatus
Compressed Airline Breathing Apparatus [ The Independence in Breathing] The Complete Range at a Glance Full face mask with lung governed demand valve Light duty airline breathing apparatus Cavair LDA Pressure
More informationInstallation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series
Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator
More informationPortable Hydrostatic Pneumatic Test Pump. Procedure Manual
Portable Hydrostatic Pneumatic Test Pump Procedure Manual Dixon Valve & Coupling Company 800 High Street Chestertown, MD 21620 800-355-1991 Fax: 800-283-4966 Specifications Dixon Portable Pneumatic Hydrostatic
More informationDetector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane
Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,
More informationATD LBS. PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8401 40 LBS. PRESSURE BLASTER INSTRUCTION MANUAL ATD abrasive blasting equipment is designed for cleaning and removing rust, scale, paint and dirt. It is the ideal method for stripping, polishing and
More informationPARTS: AIRPREP AFTERCOOLERS AND AIR DRYERS
PARTS: AIRPREP AFTERCOOLERS AND AIR DRYERS MOTOR AND FAN PARTS ITEM/MODEL ACS/ADS 250 ACS/ADS 400 ACS/ADS 750 ACS/ADS 950 ACS/ADS 1200 ACS/ADS 1600 Air motor 1300-040-03 1300-040-03 1300-040-03 1300-090-03
More informationJacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions
Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and
More informationRespiratory Protection
Respiratory Protection Purpose The purpose is to establish a set of guidelines for the selection of respiratory protection equipment, situations for its use, and training in the use of the respirator required.
More informationWARNING CPF 20/80 PARTICULATE AIR FILTER O. M
CPF 20/80 PARTICULATE AIR FILTER O. M. 04143 MC FILE NUMBER: 161-0278 DATE OF ISSUE: 06/30/78 REVISION: J, 12/2007 2007 CLEMCO INDUSTRIES CORP. One Cable Car Dr. Washington, MO 63090 Phone (636) 239-4300
More informationOPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N
OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...
More informationNiltox Breathing Air Purifier Range
Breathing Air Requirements The main standards affecting breathing air are BSEN529, EN12021 and COSHH. The requirements for a breathing air system are shown in the table opposite and the requirements for
More informationOperating Manual. Appa. Models LP/HP-A4K & LP/HP-A445K Air Quality Test Kits Manual No. AIRTST01 (Rev 7 October 2008)
Models LP/HP-A4K & LP/HP-A445K Air Quality Test Kits Manual No. AIRTST01 (Rev 7 October 2008) Operating Manual Appa AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone
More informationATD LBS. PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90 LBS. PRESSURE BLASTER INSTRUCTION MANUAL C f Pr p 65 WARNING h h er h g. ATD abrasive blasting equipment is designed for cleaning and removing rust, scale, paint and dirt. It is the ideal method
More information5 Gallon Pressure Pot with HVLP Spray Gun and Hose
California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,
More information2 in. 18 Gauge Brad Nailer. User manual
8504342 2 in. 18 Gauge Brad Nailer User manual Technical Data Capacity....100pcs Nail length... 15-50mm( 5/8-2 ) Fastener size....18gauge (1.25 1.00mm) Operation pressure 70-110PSI(4.8-7.5bar) Air inlet....1/4
More information!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7
EXEL North America, Inc. EXEL Industrial Canada, Inc. 1310 Washington St 931 Progress Ave., #7 West Chicago, IL 60185 Scarborough ONT, M1G 3V5 Ph : (800) 573 5554 Ph : (800) 450 0655 Fx : (800) 664 1511
More information2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL
2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,
More informationWARNING! Crystalline silica from bricks, cement and other masonry products
1 WARNING! DO not use a Pressure Blaster until you have read this manual and you understand its contents and warnings. These warnings are included for the health and safety of the operator and those in
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationHPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS
WIDDER TOOLS HPIC-10000-D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS Description: The WIDDER Hydrostatic Test Systems C Series is a portable, selfcontained, air driven hydrostatic
More informationGREIG FILTERS, INC. OPERATION MANUAL
GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.
More informationFILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS
FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.
More informationLARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual
LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual 002694 IntroductIon 8-1-11 Page 1 ForEWord This manual is intended for use with
More information3/8" Dr. Air Butterfly Impact Wrench
8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and
More informationCentriFlow Meter Integrated Air Entrainment System
CentriFlow Meter Integrated Air Entrainment System INSTALLATION & OPERATION MANUAL January 2004 Revision 021-4 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website:
More informationOperation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER
Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor
More informationAir Quality Test Kits Models: LP/HP-A4K and LP/HP-A445K
OPERATING INSTRUCTIONS AND REPLACEMENT PARTS Air Quality Test Kits Models: LP/HP-A4K and LP/HP-A445K Air Systems International, Inc. 829 Juniper Crescent, Chesapeake, Va, 23320 Telephone (757) 424-3967
More informationPOWER FLUSH KIT INSTRUCTIONS
1 GENERAL INFORMATION POWER FLUSH KIT INSTRUCTIONS ACE Power Flush is an ozone-safe solvent engineered specifically for flushing refrigeration and air conditioning systems. Used exactly like the old R-11
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS euro-gas@btconnect.com www.euro-gasman.com AIRCHECK OPERATING MANUAL By carefully following these instructions, the AIRCHECK with KITAGAWA gas detection tubes will enable you to
More informationThe ultimate protection & future-proofed performance
The ultimate protection & future-proofed performance As you know, it is paramount that your blasters have the best equipment to obtain maximum productivity. How can you increase productivity and advance
More informationBreathable Compressed Air
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Breathable Compressed Air Typical Hazardous Substances Biological agents
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationBinks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)
INTRODUCTION Binks SG-2 Plus TM Pressure Cup is ideal for component spraying and industrial applications where small batch production spraying is required. The 2 qt. capacity is sufficient to complete
More informationNitrogen Tyre Inflator Owner s Manual
Nitrogen Tyre Inflator Owner s Manual Model:PN-8890 Please read this manual carefully before attempting assembly or use. 1 Suit for: Motorcycle, Car, Light Truck, Bus Manual Model Nitrogen Tyre Inflation
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More information/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651
/ Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply
More informationAIR INLINE METAL SHEAR
AIR INLINE METAL SHEAR ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd. / Camarillo, CA 93011 Copyright 1997 by Harbor Freight Tools. All rights reserved. No portion of this manual or any artwork
More informationCopyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the written
MODEL G5789/G5790 13-PIECE 3 4" IMPACT WRENCH KIT INSTRUCTION MANUAL Copyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the
More informationPORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS
PORTABLE 5 GALLON AIR TANK MODEL 472 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND
More informationRegO Adapters, Connector, & Fittings
RegO dapters, onnector, & Fittings Extended Type ouplings for Vapor and Liquid Service esigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of
More informationCopyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form without the written
MODEL G5791/G5792 17-PIECE 1 2" IMPACT WRENCH & RATCHET KIT INSTRUCTION MANUAL Copyright MAY, 2008 By Grizzly Industrial, Inc. Warning: No portion of this manual may be reproduced in any shape or form
More informationPRESSURISED PAINT CONTAINER
PRESSURISED PAINT CONTAINER MODEL NO: CPP2B PART NO: 3082115 OPERATION & MAINTENANCE INSTRUCTIONS GC0913 INTRODUCTION Thank you for purchasing this CLARKE Pressurised Paint Container. Before attempting
More informationOperation and Maintenance
Page 1 Operation and Maintenance emwt-20 Mobile Wastewater Treatment System Page 2 TABLE OF CONTENTS EMERGENCY CONTACTS 2 TREATMENT TRAILER DRAWING... 3 GLOSSARY.. 4 INTRODUCTION. 4 START-UP PROCEDURES.
More informationEaton Filtration, LLC
Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual
More informationBreathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards
Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards www.domnickhunter.com domnick hunter Breathing Air Purifiers provide air
More informationLRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.
LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the
More informationEaton Filtration, LLC
Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual
More informationTechnical Information
Technical Information Installation, Operation, Installation, Operation and Maintenance and Maintenance Manual Manual Balston Model 75700-K728 Nitrogen Generator Figure 1-75700-K728 Overall Dimensions These
More informationPremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION
DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR DUAL-SUPPLY MODE OF OPERATION WARNING This manual must be read carefully by all persons who have who will have the responsibility
More informationMODEL H8253 AIR BELT SANDER INSTRUCTION MANUAL
MODEL H8253 AIR BELT SANDER INSTRUCTION MANUAL COPYRIGHT DECEMBER, 2007 BY GRIZZLY INDUSTRIAL, INC. WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL
More information4 IN. BALL LAUNCHER Engine Mounted / PTO Driven
4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationWHEELED AIR COMPRESSOR AC658HB AC708RB AC908HB AC6520HB. User Manual
WHEELED AIR COMPRESSOR AC658HB AC708RB AC908HB AC6520HB User Manual table of contents table of contents Introduction 4 Using the Operators Manual Product Identification 5 Record Identification Numbers
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS FLOJET Beer Pump Panels MODEL NO. 66134-1 66134-2 66134-3 66134-4 IMPORTANT INFORMATION This manual has been prepared to assist you in the operation of Perlick Beer
More informationOperating Procedure TITON SUBSEA BOLT TENSIONER
Operating Procedure TITON SUBSEA BOLT TENSIONER B & A Hydraulics Ltd Block 1, Units 1 & 2 Souter Head Industrial Centre Souter Head Road Altens Aberdeen Phone: 01224 898955 Fax: 01224 898787 E-Mail: TITON@bahyd.co.uk
More information20 Gallon Portable Oil Lift Drain
20 Gallon Portable Oil Lift Drain Item 66786 Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. When unpacking, make sure that the product is
More informationAC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight
Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this
More informationHot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)
Hot Compressed Air Lance Operation Manual www.heatlances.com LAB Manufacturing 9483 Reading Road Cincinnati, OH 45215 (800) 776-5830 PARTS CHECK LIST NOTE: Check all fittings & connections prior to operation.
More informationCARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition
CARTRIDGE FILTERS TECHNICAL MANUAL MT 080 Installation, commissioning and maintenance instructions 08/02 Edition 1 2 CONTENTS 1.0 PAGE INTRODUCTION 1.1 MAIN FEATURES 1.2 OPERATION 1.3 CLOSING OF HEAD WITH
More informationAIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL
AIR DRIVE ROLL FEED CARTON STAPLER MODEL: H-1031 MANUAL WARNING Before operating this stapler familiarize yourself with the safety warnings and instructions in this manual. Keep these instructions with
More information