E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

Size: px
Start display at page:

Download "E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min"

Transcription

1 Return Filters E E Tank top mounting Connection up to G¼ ominal flow rate up to l/min Description pplication In the return line circuits of hydraulic systems. Performance features Protection against wear: By means of filter elements that, in full-flow filtration, meet even the highest demands regarding cleanliness classes. Protection against malfunction: By means of full-flow filtration in the system return, the pumps above all are proteced from dirt particles remaining in the system after assembly, repairs, or which are generated by wear or enter the system from outside. Return Filter E Special features By-pass valve: The location close to the inlet port prevents dirt particles retained by the filter element from entering into the clean oil side. Removable bowl: In case of maintenance the filter bowl is removed together with the filter element - therefore dirt particles are not flushed back into the tank. Filling filter/by-pass protection strainer: The filling filter is integrated in the filter element and prevents coarse particles from entering during filling or re-filling due to maintenance or repair reasons. Filling can be carried out at the filter. Therefore the cover must be removed. In operation, the filling filter functions as a by-pass protection strainer and prevents dirt from entering into the tank when the by-pass valve is open. Port for ventilating filter: The ventilating filter thread connection x allows assembly of a ventilating filter, which assumes ventilation of the tank. The ventilating filter has to be ordered separately. Filter elements Flow direction from outside to centre. The star-shaped pleating of the filter material results in: large filter surfaces low pressure drop high dirt-holding capacities long service life Filter maintenance By using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter life. Subject to change.-e Page

2 aterials Screw-on cap: Filter head: Filter bowl: Seals: Filtermaterial: Filling filter: Polyester, GF-reinforced luminium alloy Polyamid, CF-reinforced, electrically conducting BR (FP on request) EXPOR X - inorganic multi-layer microfibre web Paper - cellulose web, impregnated with resin Polyamide, reinforced; Polyester web ccessories Electrical and optical clogging indicators are available on request. Dimensions and technical data see catalogue sheet 6.. Ventilating filters with connection thread x have to be ordered separately. Dimensions and technical data see catalogue sheet. and.. Extension pipes or diffusors on the bowl outlet are available on request. Extension pipe: correct extension pipe length ensures oil outlet below minimum oil level and prevents foaming. Characteristics ominal flow rate Return filter: Up to l/min (see Selection Chart, column ). The nominal flow rates indicated by RGO-HYTOS are based on the following features: closed by-pass valve at ν mm /s element service life > operating hours at an average fluid contamination of,7 g per l/min flow volume flow velocity in the connection lines, m/s Filling filter: up to l/min (see Selection Chart, column ) Connection Threaded ports according to ISO 8 or DI. Sizes see Selection Chart, column 9 (other port threads on request) Filter fineness µm(c)... µm(c) β-values according to ISO 6889 (see Selection Chart, column and diagram Dx) Dirt-holding capacity Values in g test dust ISO TD according to ISO 6889 (see Selection Chart, column 6) Hydraulic fluids ineral oil and biodegradable fluids (HEES and HETG, see info-sheet.). With high filling conditions we recommend an electrical conductivity ps/m at C. Temperature range - C... + C (temporary - C... + C) Viscosity at nominal flow rate at operating temperature: ν < 6 mm /s as starting viscosity: ν max = mm /s at initial operation: The recommended starting viscosity can be read from the diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 7 % p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Operating pressure ax. bar ounting position Preferably vertical, outlet downwards Page Subject to change.-e

3 Diagrams p-curves for complete filters in Selection Chart, column D flow volume at ν = mm /s ( = casing empty),6,,,,, E 6 8 ν [mm /s] D flow volume at ν = mm /s ( = casing empty),6,,,,, E 6 8 ν [mm /s] D flow volume at ν = mm /s ( = casing empty),6,,,,, E 6 8 ν [mm /s] D flow volume at ν = mm /s ( = casing empty),6,,,,, E 6 8 ν [mm /s] Subject to change.-e Page

4 Filter fineness curves in Selection Chart, column Dx Filtration ratio β for particles > x µm Filtration ratio β as a function of particle size x obtained by the ulti-pass-test according to ISO 6889 Particle size x [µm] (for particles larger than the given particle size x) Efficiency [%] The abbreviations represent the following ß-values resp. finenesses: For EXPOR X - and Paper elements: EX = β (c) = EXPOR X 7EX = β 7 (c) = EXPOR X EX = β (c) = EXPOR X 6EX = β 6 (c) = EXPOR X P = β (c) = Paper Based on the structure of the filter media of the P paper elements, deviations from the printed curves are quite probable. For screen elements: S = screen material with mesh size µm 6S = screen material with mesh size 6 µm S = screen material with mesh size µm Tolerances for mesh size according to DI 89. For special applications, finenesses differing from these curves are also available by using special composed filter media. Order Information ll filters are delivered with a plugged clogging indicator connection x,. s clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below mentioned codes. Order example: The filter E - has to be supplied with an extension pipe for a mounting depth of mm. Order description: E - / EV Part o. (Basic unit) Extension pipe ( various lengths are available on request) E : EV, EV 66, EV, EV 66 E : EV, EV, EV, EV 6 For the appropriate ventilating filters with x thread connection see catalogue sheet. and., for the appropriate clogging indicators see catalogue sheet 6.. Remarks: The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column ). Clogging indicators are optional and always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request. Page Subject to change.-e

5 Selection Chart Part o. ominal flow rate Return filter ominal flow rate Filling filter Pressure drop see Diagram D/curve o. Filter fineness see diagr.dx Dirt-holding capacity Filter finenes filling filter / by-pass protection strainer Filter surface filling filter / by-pass protection strainer Connection Cracking pressure of by-pass Symbol Replacement filter element Part o. l/min l/min g µm cm bar kg Ventilating filter thread connection x Weight E D/ EX G¼, V7.8- -,7 E -6 - D/ EX - - G¼, V ,7 E D/ 6EX - - G¼, V ,7 Remarks E D/ P - - G¼, P7.8- -,7 E -9 8 D/ EX 9 8 G¼, K7.8-, E -6 D/ EX 8 G¼, K7.8-6, E -8 9 D/ 6EX 8 G¼, K7.8-8, E - 6 D/ P 8 G¼, K7.8-, E -9 - D/ EX - - G¼, V7.8- -, E -6 - D/ EX G¼, V , E -8 - D/ 6EX G¼, V , E - - D/ P - - G¼, P7.8- -, E -9 D/ EX 8 G¼, K7.8-, E -6 D/ EX 7 8 G¼, K7.8-6, E -8 D/ 6EX 76 8 G¼, K7.8-8, E - D/ P 8 G¼, K7.8-, t mm /s (ISO VG6 at ca. C) Paper media supported with metal qauze Open connection for ventilating filter. Please assemble ventilating filter before operating. Subject to change.-e Page

6 Dimensions Version without connection for ventilating filter Version with connection for ventilating filter B Z I+(EV-K) S Ventilating filter (not included in basic equipment) H G F Q H G F U Ø E Ø D ØE ØD O-ring (included in basic equipment) Ø C EV K ØC Dia hole in reservoir R Extension pipe on request X B Version with connection Required mounting surface Connection x, 9º for clogging indicator 9º 9º O O P O L W L C W Connection x for ventilating filter Version with connections on request 9º P V For dimension EV see selection chart easurements Type B C min/max D E F G H I K L O Q R S U E G¼ G 6 8/ 9, , E G¼ G 6 8/ 9, , Type V W X Z E 68 7 E 67 7 Symbols T T Page 6 Subject to change.-e

7 Spare Parts Pos. Designation Part o. Screw-on cap with valve (, bar) and Pos. Screw-on cap with valve (, bar) and Pos. E. E. O-ring x 7. Filter element see Chart / col. Filter bowl E * E.9 Filter bowl E * E.9 O-ring 9 x O-ring 6 x Connection for ventilating filter O-ring x E.9 *Specify mounting depth (EV) in mm The functions of the complete filters as well as the outstanding features of the filter elements assured by RGO-HYTOS can only be guaranteed if original RGO-HYTOS spare parts are used. 7 6 Quality ssurance Quality management according to DI E ISO 9 To ensure constant quality in production and operation, RGO-HYTOS filter elements undergo strict controls and tests according to the following ISO standards: ISO 9 ISO 9 ISO 9 ISO 968 ISO 6889 ISO 8 Verification of collapse/burst pressure rating Verification of fabrication integrity (Bubble Point Test) Verification of material compatibility with fluids Evaluation of pressure drop versus flow characteristics ulti-pass-test (evaluation of filter fineness and dirt-holding capacity) Determination of resistance to flow fatigue using high viscosity fluid Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Illustrations may sometimes differ from the original. RGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. Subject to change.-e Page 7

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means

More information

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 1 bar Flow rates to l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for both

More information

Flow rates to 200 l/min

Flow rates to 200 l/min LMP MULTIPORT - - Maximum pressure bar low rates to l/min Technical data ilter housing (Materials) Head: luminium Housing: ataphoresis-painted Steel ypass valve: rass - luminium Pressure Working pressure:

More information

D e s c r i p t i o n

D e s c r i p t i o n MPS Series D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and

More information

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I. LMP 900-90 Filter element in according to D 550 Style S Style D.I. D.I. Maximum pressure 30 bar F l o w r a t e s t o 0 0 0 l / m i n 6 Technical data Filter housing (Materials) Head: nodised luminium

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n LMP Maximum pressure 8 bar F l o w r a t e s t o 6 l / m i n Technical data Filter housing (Materials) Head: luminium Housing: ataphoresis Painting ypass valve: rass - luminium Pressure LMP length: - -

More information

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Fixed Displacement Pump KFA for commercial vehicles in open circuits RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

Air preparation units

Air preparation units Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

Check valve hydraulically pilot operated

Check valve hydraulically pilot operated Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents

More information

Compressed Air Conditioning Catalog Chapter I

Compressed Air Conditioning Catalog Chapter I Compressed Air Conditioning Catalog Chapter I 2 Compressed Air Conditioning Welcome Welcome New technologies and materials, design innovations and the integration of bus-suitable electronics have opened

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated Pressure relief valve, direct operated RE 570/0.05 Replaces: 06.03 /8 Type DBD..K Size Component series X Maximum operating pressure 500 bar Maximum flow 0 l/min K9- Table of contents Contents Page Features

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100 Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems

More information

2-way flow control valve Model 2FRM 6

2-way flow control valve Model 2FRM 6 R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated ressure relief valve, direct operated R 25402/05.0 Replaces: 10.05 /1 ype DBD Nominal sizes to 0 Component series 1X Maximum operating pressure 0 bar Maximum flow 0 l/min H5585 Overview of contents Contents

More information

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0 ir line equipment P1H, PTH Filter/Regulator- Lubricator Combination Units 07 Series Compact design Filter removes liquids and solid particles down to 5 µm Push to lock adjusting knob with tamper resistant

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa Max. operating pressure

More information

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER PM Pressure Filters MEDIUM PREURE INLINE FILTER Pressure Filters PM PM MPa (0 bar) Port sizes: 1/ 1 Flow rates: 10 l/min TECHNICAL DATA Max. working pressure: MPa (0 bar) Max. test pressure: MPa (0 bar)

More information

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with gauge suitable for ATEX 1 00119372 Version Parts Mounting orientation Working min./max. Medium Medium temperature

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

Technical Data Sheet TI-F50 Locking Units series KFH

Technical Data Sheet TI-F50 Locking Units series KFH English translation of German original Locking Units series KF Further important practical advice is given in Operating Manual BA-F50., Rod diameter 18 mm 50 mm øz 8 L 2 6 x 6 0 min. 4x30 KF 18 to KF 32,

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5. Series 17 Pressure booster Page General Pressure boosters ø 4 Pressure boosters ø 4 c/w air pressure regulator Pressure booster ø 63 Pressure booster ø 63 c/w air pressure regulator Pressure booster ø

More information

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6 Úprava stlačeného vzduchu EWO VMA List of Contents System description Individual Units Pre-Filters 3 Micro-Filters 4 Activated-Charcoal-Filters 5 Combinations 6 Accessories and Main spare parts 6 Service

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request www.atos.com Table TA60obs/E Axial piston pumps type PVPY- (-R, -) variable displacement, with mechanical controls obsolete components - availability on request PVPY are variable displacement axial piston

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

Pressure-Relief Cartridge Valve, Size 4

Pressure-Relief Cartridge Valve, Size 4 Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in

More information

STAD-C. Balancing valves DN 15-50

STAD-C. Balancing valves DN 15-50 STAD-C Balancing valves 15-50 IMI TA / Balancing valves / STAD-C STAD-C The STAD-C balancing valve has been specially developed for use in indirect cooling systems but performs just as effectively in refrigerated

More information

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150, CARTRIDGE FILTERS Models: CF50, CF75, CF00, CF50, The installation of this product should be carried out by a qualified pool technician, following the installation instructions provided in this manual.

More information

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

BIMBAR INFLATABLE PACKERS AND ACCESSORIES BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise

More information

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL HYDRAULIC OORS APPLICAION» Skid Steer Loaders» etal working machines» renchers» Augers» Agricultural machines» Road building machines» Special vehicles» ine machines» Woodworking and sawmill machinery»

More information

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid INTERNATIONAL STANDARD ISO 23181 First edition 2007-08-15 Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid Transmissions hydrauliques Éléments

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves STAD-D Balancing valves Balancing valve for domestic water systems, DN 15-50 Balancing valves IMI TA / Balancing valves / STAD-D STAD-D The STAD-D balancing valve delivers accurate hydronic performance

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Technical data sheet. Type overview. Technical data. Safety notes.   T5-R2.. Open-close en v Subject to changes 1 / 3 Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling

More information

Directional Control Valves Technical Information Model 1500

Directional Control Valves Technical Information Model 1500 Single spool monoblock valve. 26.4 l/min [7 US gal/min] maximum flow. 138 bar [2 psi] maximum pressure with relief. 27 bar [3 psi] maximum pressure without relief. Garden tractors, mowers, utility equipment,

More information

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke : Hand pump type CH Product documentation Operating pressure p max : Displacement volume V max stroke : 300 bar 8.3 cm 3 /stroke D 7147 CH 04-2018-1.1 by HAWE Hydraulik SE. The reproduction and distribution

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

FILTER BYPASS CONTROL

FILTER BYPASS CONTROL Differential Control Valve Series 110 The Series 110 Differential Control Valve is designed to accurately control the pressure difference between any two points. In some systems this means the valve remains

More information

Two-stage valve type NE

Two-stage valve type NE Two-stage valve type NE Product documentation Operating pressure pmax: Flow rate Qmax: 700 bar (High pressure) 80 bar (Low pressure) 25 lpm (High pressure) 180 lpm (Low pressure) D 7161 03-2017-1.0 by

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification

More information

STAD. Balancing valves DN 15-50

STAD. Balancing valves DN 15-50 STAD Balancing valves DN 15-50 IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for use on the

More information

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

DEWATERING PUMP SOLUTIONS. Pneumatic pumps DEWATERING PUMP SOLUTIONS Pneumatic pumps PUMP UP YOUR BUSINESS A pneumatic pump is a great choice when failure is not an option. They re easy to use, safe and can handle almost anything you throw at them.

More information

HYDRAULIC MOTORS MV APPLICATION GENERAL

HYDRAULIC MOTORS MV APPLICATION GENERAL HYDRAULIC V APPLICAION» Conveyors» etal working machines» Agriculture machines» Road building machines» ining machinery» Food industries» Special vehicles» Plastic and rubber machinery etc. CONENS Specification

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

Two-port valves, male threaded, PN25

Two-port valves, male threaded, PN25 4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information

Fuel Filters DN15 DN25. elektrogas.com DE

Fuel Filters DN15 DN25. elektrogas.com DE FF Fuel Filters DN15 DN25 elektrogas.com DE180 0914 FF Fuel Filters Contents Description.. 2 Features.. 2 Functioning and application. 3 Accessories and optionals 4 Technical specifications 4 Gas flow

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Pressure-limiting valve and pre-load valve type MVG, MVE and MVP Product documentation Directly controlled Operating pressure pmax: Flow rate Qmax: 700 bar 8 lpm D 3726 02-2016-1.3 by HAWE Hydraulik SE.

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09. Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size. eries ow to Order opper, fluorine and silicon-free + Low particle generation il ote 1) ote 2) part no. lean series hread type Rc racket assembly ote ) ote 9) 1.0a 0.2a / -20 49-01 49-2-01 ilter regulator

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6 List of Contents VMA System description Individual Units Pre-Filters 3 Micro-Filters Activated-Charcoal-Filters 5 Combinations Accessories and Main spare parts Service Units G 1 / Pre-Filter Micro-Filter

More information

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw. Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces

More information

Products no longer available

Products no longer available Technical data sheet R3 / R3G Change-over ball valve, 3-way, with internal thread for closed cold and warm water systems for switching functions on the water side and 2-point controls in air-handling and

More information

STAD. Balancing valves DN (MD60, MD61, MD62)

STAD. Balancing valves DN (MD60, MD61, MD62) STAD Balancing valves DN 15-50 (MD60, MD61, MD62) IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited

More information

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

Pressure-controlled shut-off valve type CNE

Pressure-controlled shut-off valve type CNE Pressure-controlled shut-off valve type CNE Product documentation Screw-in valve Operating pressure pmax: Flow rate Qmax: 500 bar 30 lpm D 7710 NE 09-2013-1.3 by HAWE Hydraulik SE. The forwarding and reproduction

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

Bores: ø 10, 16, 20, 25, 32 mm

Bores: ø 10, 16, 20, 25, 32 mm > Series CGLN wide opening parallel grippers CATALOGUE > Release 8.8 Series CGLN wide opening parallel grippers New version Bores: ø 0, 6, 20, 25, 32 mm»» High installation versatility»» Rack and pinion

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information