Service Test Unit for ROSS Proportional Valves RESK
|
|
- Posy Owen
- 5 years ago
- Views:
Transcription
1 Service Unit for Proportional Valves Page 1 Technical Description ROSS Service Test Unit for ROSS Proportional Valves Technical Description V 1.0 / 2015 RESK For all Prop Valve Models Connections on both Sides Measuring Pressure Transformer included Iss.: August 4, 2015 ROSS EUROPA GmbH Robert-Bosch-Strasse 2 D Langen Phone: Fax: info@rosseuropa.com
2 Service Unit for Proportional Valves Technical Description Page Contents: Page The Touch Screen... 3 General Information... 4 Test Preparation... 5 Indications / Displays... 6 Test AUTOMATIC... 6 Graphics Analysis... 7, 8 Components needed for testing a ROSS Proportional Valve: Test Unit RESK (see photo on the left) Adapter Plate Electronic Service Unit (as described in this document) Adapter Cable For comprehensive information, please refer to Technical Leaflet RESK
3 Service Unit for Proportional Valves Technical Description Page The Touch Screen Basic Setting Options: Set Value (V, ma) Actual Value (V, ma) bar/psi (switchable) Measured Times (ms) Reference Sensor Power Supply Valve Valve Type Type Pressure Range Valve Step Quantity STEP-Chart Edit Actual Y-Scale Measured Cycle Time STEP Result Test Mode X-Axis Pre-Select
4 Service Unit for Proportional Valves Technical Description Page General Information The Service Unit consists of two components: one pneumatic and one electronic. Through a simple exchange of sub-bases in connection with a 2 liter test volume, gauge and electronic pressure sensor, all ROSS proportional valves can be tested. Voltage is supplied by the electronic element (Service Box) which secures the testing procedure following a defined analysis. Optionally, the Service Box can be combined with a valve and connected directly to the IS machine. In that case, all relevant data, such as set value, actual value, operation voltage and actuation times are measured and indicated. Through a 7 Touch Screen all valve-specific parameters can be set, these are: Valve Type (Nominal Diameter) Pressure Range of the Valve Set Value Actual Value presetting (current, voltage) Graphic Representation of Set and Actual Value. For the X-axis (time), a fixed setting ( 600 ms, 1.2 sec. 2.4 sec. 6.0 sec. ), or an automatic adjustment guided by the previous measuring results, can be selected. The Y-axis (pressure) will automatically readjust to an optimal graphic representation. On the test bench three test modes can be selected. For a functional test, the set value needs to be set to 50% of the nominal value, the inlet pressure must be set to +0.1 bar in the valve segment on the screen. Test AUTOM: Use the Test Selector (upper, middle touch field) to select Test AUTOM. Shifting the toggle switch towards MANUAL, a pilot control impulse of 350 ms is triggered. At this fixed time, the full cycle can be graphically represented. Test MANUAL: Preparations as described above, however, in this case cycle time (respectively ON-time) is solely defined through the position of the toggle switch. In this mode all measured values are readable. STEP: On the Step-Page, time steps (in ms.) as well as assigned pressures can be set. On the Main Page the number of steps is defined. Start the procedure by shifting the toggle switch towards
5 Service Unit for Proportional Valves Technical Description Page STEP. Repeat running through the Time/Pressure chart until the step counter has achieved NULL (ZERO) or the toggle switch has been moved to the neutral position. EXTERNAL Mode: This mode involves the use of both connectors X10 and X11, located on the right hand side of the service box. X10 is connected with the connector removed from the valve. X11 is connected with the valve. The toggle switch is absolutely required to be in the neutral position. The process is controlled through the valve s set value. Test Preparation: The information given on the label must be transfered to the unit, i.e.: Pressure Range in terms of bar (not max. pressure!), Set Value / Actual Value mode (V or ma) and Type (Nominal Diameter). All fields framed in blue and white are adjustable. Connect the service box with the external pressure sensor, Port X12 at the right-hand side. Use the switch above the IEC connection to apply mains voltage. Inlet Pressure: Set valve s pressure range +0.1 bar using the gauge. For valves with pressure range exceeding 0-5 bar, inlet pressure must be set to 5 bar. Wrongly set inlet pressures directly influence actuation time analysis. Type of Set / Actual Value: Use soft switch ( Set ) to set mode (to be read from the nameplate): Electronic Piloting. Type: Use soft switch ( Type ) to set nominal diameter (ND) given on valve s data sheet. Range: Use soft switch ( Span ) to set pressure range (not max. pressure range) given on the nameplate. Set Value: In the upper, left-hand, blue touch field, 50% of reference value must be set: Set Value : 0-10 V -> 5.00 to be set. Set Value : 0-20 ma -> 10.0 to be set. Set Value : 4-20 ma -> 12.0 to be set.
6 Service Unit for Proportional Valves Technical Description Page X-Scale: Four time ranges can be preset: 1:1 defined 600 ms, 1:2 corresponds to 1.2 sec., 1:4 corresponds to 2.4 sec., 1:10 corresponds to 6.0 sec. Use Automatic to select the optimal measuring range from previous measuring. Y-Scale: For a distinct and clear representation of measuring results, the unit self-adjusts on three ranges, guided by previous measurements. Normally, the valve range is selected. In case of smaller set values, the Y-axis is set on ½ of the set value, or ¼ of the set value, to be read in the upper area above the Y-axis. Connect valve with Port X1 (left side of the device), using the cable supplied with the unit. For the initial test, the AUTOMATIC mode is recommended. This mode can be set via the touch field above the graphics area. By shifting the toggle switch towards Manual, the test cycle will be started. The result will be shown in the INFO line and in the yellow displays in the upper area. To the upper left, the cycle time is shown. In this mode, 351 ms should be shown. This indication is of particular relevance for a valve test on the IS machine. Analysis of the measured results: Indications: SV: adjustable set value AV: measured actual value (in terms of V or ma, respectively) Bar: measured actual value (in terms of bar) T10: time in ms, until actual value reaches 50 mbar T95: time in ms, until the actual value reaches 95% of set value T-Exhaust: time in ms, until actual value falls below 100mbar after shut-off Ref.AV: measured value of external pressure sensor, in terms of bar Power supply: internal/external voltage supply of valve Puls active cycle time during measuring process Test AUTOMATIC: This test procedure focuses primarily on repeatability. Indications for actual values (V, ma, bar) as well as externally measured pressure values cannot be displayed due to the short measuring time. Priority is on the graphic representation of the complete cycle.
7 Service Unit for Proportional Valves Technical Description Page Rise time, fall time and control behavior are available for the analysis. The info line will show the analysed result. As only one information item can be represented, the deviation having occurred first will be indicated. 1) Pressure deviation in regulating mode 2) Rise time too small or too large 3) Fall time too large Rise time too fast: Indicative of changed parameters or mechanical problems in the valve. If regulating behavior is within a range of ±20 mbar, valve operation may continue, otherwise repair will be necessary. Rise time too slow: Indicative of changed parameters or mechanical problems in the valve. Repair will be necessary. Fall time too slow: Indicative of changed parameters or mechanical problems in the valve. Repair will be necessary. Pressure deviation (in regulating mode) This fault will be indicated, when the pressure difference between the valve s actual value and the external pressure sensor is larger ±25 mbar. In that case repair is necessary. This fault is mainly caused by the valve pressure sensor, or by leakage in the valve at the inlet or the outlet. The graphic representation shows clear control variations. External mode: In this mode all indications are active. Basic requirement for starting a measuring cycle is a zero phase of the set value, at least 10 ms. Graphics Analysis: For the analysis of the measuring result the displayed graphic is of particular help. On the Test Bench: 1. The actual value should not vary more than ±30 mbar around the set value. If the inlet pressure is stable and the tolerance level is exceeded, an abnormal regulating behavior may be assumed.
8 Service Unit for Proportional Valves Technical Description Page If the actual value shows a zigzag curve below the set value, leakage in the exhaust area of the valve is likely to be the cause. If no leakage can be identified on the test bench, the valve is defective. 3. If the actual value shows a zigzag curve above the set value, leakage in the pressurizing area of the valve is likely to be the cause. If the test pressure is set correctly, the valve is defective. On the IS-Machine: 1. The Power Supply field shows the supply voltage of the valve. It should be within the maximum tolerance of ±10%. If this is not the case, valve behavior is too fast or too sluggish. 2. The actual value should not vary more than ±50 mbar around the set value. If the inlet pressure is stable and the tolerance level is exceeded, an abnormal regulating behavior may be assumed. 3. If the actual value shows a strongly varying curve around the set value, leakage in the cylinder system or insufficient air supply may be the cause. 4. Should blow-out processes with high volume flow be involved, the occurrence of such a phenomenon is possible. 5. The pulse time is analogous to the piloting procedure. If several impulses are visible in the machine cycle, the respective time will always refer to the last impulse. For further information, our Standard Worksheet is available, including step-by-step, illustrated testing instructions.
9 Standard Work Sheet Testing Instructions Updated: Work Station: Testing Facility Product: Proportional Valve Job: Step-by-Step Testing No. Action Photo Remark 1 Mount Adapter Plate on test unit 2 Mount valve on Adapter Plate 3 Inlet Pressure: Set valve s pressure range +0.1 bar using the gauge For valves with pressure range exceeding 0-5 bar, inlet pressure must be set to 5 bar Important: Wrongly set inlet pressures directly influence actuation time analysis Note: If pressure builds up at outlet side too, valve is defective, due to leak at inlet side. 4 Connect service box to IEC connection Note: Several connecting adaptors are supplied with the test unit
10 Standard Work Sheet Testing Instructions Updated: Work Station: Testing Facility Product: Proportional Valve Job: Step-by-Step Testing No. Action Photo Remark 5 Use the switch above the IEC connection to apply mains voltage 6 Use soft switch ( Set-V. ) to set mode (to be read from the nameplate: Electronic Piloting ). 7 Use soft switch ( Type ) to set nominal diameter (ND) Note: Nominal diameter is given on valve s data sheet Data on request. Please contact ROSS Europa 8 Use soft switch ( Span ) to set pressure range (not max. pressure range) given on the nameplate. Use format X.Y0 and confirm with Ret (For example: 4.00 for 0 4 bar )
11 Standard Work Sheet Testing Instructions Updated: Work Station: Testing Facility Product: Proportional Valve Job: Step-by-Step Testing No. Action Photo Remark 9 In the upper, lefthand, blue touch field a 50% set value reference must be set Set-V.: 0-10 V -> 5.00 to be set Set-V.: 0-20 ma -> 10.0 to be set Set-V.: 4-20 ma -> 12.0 to be set 10 Normal Mode: Connect valve with Port X1 (left side of the device), using the cable supplied with the unit Important: Switch off mains voltage prior to this step! 11 Connect the service box with the external pressure sensor, Port X12 at the right-hand side
12 Standard Work Sheet Testing Instructions Updated: Work Station: Testing Facility Product: Proportional Valve Job: Step-by-Step Testing No. Action Photo Remark 12 For the initial test, the AUTOMATIC mode is recommended. This mode can be set via the touch field above the graphics area Note: Apply mains voltage prior to Step X-Scale: Four time ranges can be preset: 1:1 defined 600 ms, 1:2 corresponds to 1.2 sec., 1:4 corresponds to 2.4 sec., 1:10 corresponds to 6.0 sec 14 By shifting the toggle switch towards Manual, the test cycle will be started Note: Use Automatic to select the optimal measuring range from previous measuring Note: Initial cycle is required. After second time shifting the toggle result info will be correct 15 The result will be shown in the INFO line and in the yellow displays in the upper area. To the upper left, the cycle time is shown Note: In this mode, 351 ms should be shown. This indication is of particular relevance for a valve test on the IS machine
13 Standard Work Sheet Testing Instructions Updated: Work Station: Testing Facility Product: Proportional Valve Job: Step-by-Step Testing No. Action Photo Remark 16a Rise time too fast: If regulating behavior is within a range of ±20 mbar, valve operation may continue, otherwise re-calibrating will be necessary by ROSS 16b Rise time too slow: Case A: Mechanical Problems Check of mechanical blocking at inlet port and inlet solenoid will be necessary Case B: Changed Parameters Re-calibrating will be necessary by ROSS 16c Fall time too slow: Case A: Mechanical Problems Check of mechanical blocking at exhaust port and exhaust solenoid will be necessary Case B: Changed Parameters Re-calibrating will be necessary by ROSS 16d Pressure deviation Case A: Leakage Check and possibly exchange of both solenoid armatures will be neccesary 17 For further information about graphics analysis, manual test and external mode (on IS Machine), please refer to our Technical Description Service Unit for Proportional Valves Case B: Defect Pressure Sensor Exchange of pressure sensor will be necessary by ROSS
14 Test Unit for ROSS -Proportional Valves RESK Page 1 of 6 E SPECIFICATIONS Maximum Pressure: 5 bar. Test pressure (pressure supply at G 1 inlet), must be set to nominal valve pressure. For valves with nominal pressure exceeding 5 bar, test pressure must be set to 5 bar. Temperature: 0 to 85 C Port Size: G 1 Model Number: RESK Dimensions - mm Sensor with Connector for Electronic Test Box 0 to 5 bar, 0 to 5 volts Manual Exhaust Cable - 3 m Inlet ca G ROSS EUROPA GmbH Robert-Bosch-Strasse 2 D Langen Tel.: Fax: info@rosseuropa.com ROSS
15 Test Unit for ROSS -Proportional Valves Adapter Plate Proportional Valve Illustration Model Numbers 01-SOP SOP SOP ND 9,5 - ND 10,5, GPS-version RESK Page 2 of 6 E Adapter Plate Model Number RESK P P P P P P P P ND 12, Bosch-version 095P P P P P P P P P P ND 7,0, Bosch-version 120P Valve 120P21, Sklostroj-version 120P P P P RESK P P ND 12, 120P14, Heye-version ROSS EUROPA GmbH Robert-Bosch-Strasse 2 D Langen Tel.: Fax: info@rosseuropa.com RESK RESK RESK ROSS
16 Test Unit for ROSS -Proportional Valves Illustration Proportional Valve Adapter Plates Numbers 01-SOP SOP SOP SOP SOP SOP SOP SOP SOP SOP SOP SOP SOP SOP SOP SOP ND 14, ROSS Proportional Valve RESK Page 3 of 6 E Model Number Adapter Plates RESK P ND 20, ROSS Proportional Valve 095P P P RESK ND 9,5, ROSS Proportional Valve ROSS EUROPA GmbH Robert-Bosch-Strasse 2 D Langen Tel.: Fax: info@rosseuropa.com RESK ROSS
17 2 Test Unit for ROSS -Proportional Valves RESK Page 4 of 6 E Required Accessories Electronic test box for all proportional valve models. Connecting/porting options at both sides, power cable included. Model Number: RESK Shut-off Valve, G 1 Model-No.: YD1523C6002 Pressure Regulator, G 1 Model-No.: C5213K6017 Pressure Gauge, G 1/4 Model-No.: W5400A ROSS fi lb/in2 bar Ambient/Media Temperature: 4 to 80 C. Flow Medium: compressed air, filtered. Ambient/Media Temperature: 0 to 60 C. Flow Medium: compressed air, filtered. Regulated Pressure: 0.5 to 12 bar. Housing: ø 54 mm. Pressure Range: 0 to 14 bar. ROSS EUROPA GmbH Robert-Bosch-Strasse 2 D Langen Tel.: Fax: info@rosseuropa.com ROSS
18 Test Unit for ROSS -Proportional Valves RESK Page 5 of 6 E Adapter Cable Ref. No. Connector for Valve RESK Harting, square-type (with gold contacts) 120P P V2 120P P V2 120P P P V2 RESK Wieland, square-type 01-SOP SOP SOP SOP P P P V2 095P SOP P P P P P P P P P RESK Harting, square-type (Sklostroj-wiring) 120P RESK (2x) M12, 5-pin 01-SOP SOP V2 01-SOP SOP SOP SOP SOP SOP SOP SOP P RESK M12, 5-pin 01-SOP SOP SOP SOP P P P P P RESK M12, 8-pin 01-SOP P P P P P ROSS EUROPA GmbH Robert-Bosch-Strasse 2 D Langen Tel.: Fax: info@rosseuropa.com ROSS
19 Test Unit for ROSS -Proportional Valves RESK Page 6 of 6 E Spare Parts Pressure Gauge Model-No.: RESK Pressure Transmitter, incl. 3 m Cable with Connector Model-No.: RESK Port Size: G 1/2, radial, bottom-ported Pressure Range: 0 to 10 bar Safety Precautions Before exchanging a valve, air supply must be shut off. All equipment to be used by trained staff only. ORDERING INFORMATION: For testing a ROSS Proportional Valve, the following components are required: Test Unit RESK Adapter Plate (see Pages 2 and 3 for appropriate design) Electronic Test Box RESK (see Page 4 for details) Adapter Cable (see Page 4) Pressure Regulator (see Page 4) Shut-off Valve, (see Page 4) ROSS EUROPA GmbH Robert-Bosch-Strasse 2 D Langen Tel.: Fax: info@rosseuropa.com ROSS
BULLETIN E485B. Poppet Valve Construction Customized Solutions Plug-and-Play Design. Subject to technical modifications.
BULLETIN E485B Poppet Valve Construction Customized Solutions Plug-and-Play Design www.rosseuropa.com 1 Glossary Response Time The smallest nominal value difference that causes a change of the outlet pressure,
More informationBULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.
BULLETIN E485A Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design www.rosseuropa.com 1 Glossary Response Time The smallest nominal value difference that causes a change
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationSPCH/ Blowing block
> > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationBSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.
1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationMULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
More informationPneumatic turret stop with 6, 8 and 12 stop positions for automation
SOMATEC Sondermaschinen-Vorrichtungen Komponenten für Maschinenbau Klaus Mayer Gewerbestraße 19 88636 Illmensee Telefon 07558/1441 www.somatec-mb.de Telefax 07558/674n Pneumatic turret stop with 6, 8 and
More informationSPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection
SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationGM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
More informationGas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
More informationNeles ValvGuard VG9000H Rev 2.0. Safety Manual
Neles ValvGuard VG9000H Rev 2.0 Safety Manual 10SM VG9000H en 11/2016 2 Neles ValvGuard VG9000H Rev 2.0 Safety Manual Table of Contents 1 General information...3 1.1 Purpose of the document... 3 1.2 Description
More informationData Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic
Data Sheet T 8389 EN Series 3730 and 3731 Types 3730-2, 3730-3, 3730-4, 3730-5 and Type 3731-3 Electropneumatic Positioners EXPERTplus Valve Diagnostic Application Positioner firmware to detect potential
More informationSeries 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)
Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Application Positioner firmware for early detection of control valve faults giving maintenance recommendations. Valid
More informationDPC-30 DPC-100. Reference Manual
DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationEXPERIMENT 2 LEVEL CONTROL SYSTEM
EXPERIMENT 2 LEVEL CONTROL SYSTEM 1.0 OBJECTIVE To study the response of level control process in open tank using the PID controller. 2.0 INTRODUCTION TO THE APPARATUS (MODEL WLF922). a) The process consists
More informationISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION
PROPORTION AIR ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS Hazardous area classification Description / identification General specifications Connection
More informationEXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM
EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM 1.0 OBJECTIVE To study the response of gas pressure control using PID controller. 2.0 INTRODUCTION TO THE APPARATUS a) The process plant consists of two air vessels
More informationAUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP
USER MANUEL AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP TIRE EQUIPMENT MANUFACTURER 1.866.409.RACK WWW.MARTINSINDUSTRIES.COM info@martinsindustries.com PARTS Verify that the following components
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationRC 195 Receiver-Controller
Document No. 129-082 RC 195 Receiver-Controller Product Description The POWERS RC 195 Receiver-Controller is a pneumatic instrument that receives one, two or three pneumatic inputs. It produces a pneumatic
More informationCOSMO INSTRUMENTS CO., LTD.
Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time
More informationOperating instructions Electrical switching facility pco
Operating instructions Electrical switching facility pco from software version V1.33 on TABLE OF CONTENTS 1. Before you start... 4 1.1 Brief description... 4 1.2 Using this manual... 4 2. pco integrated
More informationENS-200 Energy saving trainer
ENS-200 Energy saving trainer Find out about the essential aspects of energy efficiency in compressed air installations Save money Put it into practice Take care of the environment Get training www.smctraining.com
More informationcompact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP
00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle
More informationCompact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min
Compact Ejectors Suitability for Industry-Specific Applications Applications Handling of air-tight as well as porous workpieces supply and vacuum monitoring in automated systems For use in sheet metal
More informationUSER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH
USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT
More informationSafety Relief Valve HON 832
Safety Relief Valve HON 832 product information serving the gas industry worldwide Application, characteristics, technical data Application 2 As leak gas SRV with internal vent connection (function class
More informationSSL. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Direct flow measurement with CMOSens technology for nominal flow rates from 0 ml N to 0 l N High accuracy and reproducibility Ingress protection IP Type can be combined
More informationFTC130 Transmitter. Operating Manual
Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationMeasuring range Δp (span = 100%) Pa
4.4/ RLE 5: Volume-flow controller, continuous How energy efficiency is improved Enables demand-led volume flow control for the optimisation of energy consumption in ventilation systems. Areas of application
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationMoveRoll Conveyor Operating and Maintenance Manual
MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.
More informationGP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI
GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure
More informationREASONS FOR THE DEVELOPMENT
7 Series 7 Series +24VDC VDC OUTPUT MICROPROCESS. E P IN EXH OUT 7 Series 7 ø,8 8 7 Series 9 5 8 9 7 Series Display features The proportional regulator has a 3 /2 digit display and a three-pushbutton
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationInoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.
Inoxair Repair Manual Edition: 12/2010 Content 1) Serial number 2) Technical data 3) Functional principle 4) Problem analysis 5) Removal 6) Repairs 7) Circuit diagram and cable-connection-plan 8) Pneumatic
More informationAir preparation units
Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator
More informationOPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N
OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...
More information3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX
/-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.
More informationValve Communication Solutions Axiom
Axiom Detect automated valve problems... before they shut down your process Reasons for Automated On/Off Valve Failures Monitor Fail Solenoid Fail Actuator Fail Coupling Break Too Slow Leaking Sticking
More informationThe Discussion of this exercise covers the following points:
Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring
More informationMASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers
MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that
More informationPart 4: Pressure regulators
INTERNATIONAL STANDARD ISO 19973-4 Second edition 2014-03-01 Pneumatic fluid power Assessment of component reliability by testing Part 4: Pressure regulators Transmissions pneumatiques Évaluation par essais
More informationPROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road
PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves
More informationModel 130M Pneumatic Controller
Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate
More information2/2-Way Proportional Valve (motor-driven)
2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationGas Pressure Regulator HON 200
Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails
More informationTECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH
TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationWhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01
WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function Printed in Germany Edition 01 1 6 Technical Description Integrated gas-air system with high power
More informationInstruction Manual EMA 84 Digital Pressure Gauge
Instruction Manual EMA 84 Digital Pressure Gauge halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationThe Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times
Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 055 D01 Two stage operating mode G-(LEP)Z 055 D01 3.0 Printed in Germany Edition 05.11 Nr.
More informationOld documentation - Only for your information! Product is not available any more!
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 055 D01 Two stage operating mode G-(LEP)Z 055 D01 3.0 Printed in Germany Edition 05.11 Nr.
More informationDIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM
DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external
More informationPressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.
Series 17 Pressure booster Page General Pressure boosters ø 4 Pressure boosters ø 4 c/w air pressure regulator Pressure booster ø 63 Pressure booster ø 63 c/w air pressure regulator Pressure booster ø
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationPZN-plus. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes Gripping force 580 N..
PZN-plus Sizes 40.. 300 Weight 0.43 kg.. 43.5 kg Gripping force 580 N.. 38000 N Stroke per finger 3 mm.. 35 mm Workpiece weight 2.9 kg.. 190 kg Application example Insertion tool for assembling small to
More information2/ Port G1/4
CATALOGUE > Release 8.8 > Series ER100 digital electro-pneumatic regulators Series ER100 digital electro-pneumatic regulators Port G1/4 Compact design Digital display Analog and digital input Programmable
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationECL Comfort 110, application 131 (valid as of software version 2.00)
Operating Guide ECL Comfort 110, application 131 (valid as of software version 2.00) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /
More informationTechnical Data Sheet MF010-O-LC
Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode G-(LEP) 057 D01 3.10 Printed in Germany Edition 05.11 Nr. 249 584 1 6 Technical
More informationOld documentation - Only for your information! Product is not available any more!
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode G-(LEP) 057 D01 3.10 Technical description Multifunctional gas control valve as
More informationAUTOMATIC GAS MANIFOLDS
AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com
More informationLocator Locator-D-Lux Air-Saver G1 Air-Saver G2
170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationMass Flow Meter (MFM) for gases
Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationAHE58/59 AC Servo System
AHE58/59 AC Servo System HMI-12 User Manual Safely INstruction Please read this manual carefully, also with related manual for the machine head before use. For perfect operation and safety, installing
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system G-GD 057 D01 Zero pressure regulator G-ND 057 D01 3.12 Technical description Multifunctional gas
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationConstant Pressure Inlet (CCN) Operator Manual
Constant Pressure Inlet (CCN) Operator Manual DOC-0125 Revision J 2545 Central Avenue Boulder, CO 80301-5727 USA C O P Y R I G H T 2 0 1 1 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I
More informationDiscontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.
Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationTightness control TC. Product brochure GB 3 Edition AGA
Tightness control TC Product brochure GB 3 Edition 07.14 AGA Test of two safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted
More informationE28/Q28 Safety Exhaust Valve Externally Monitored
E8/Q8 Safety Exhaust Valve Externally Monitored ulletin 9EM4 the total systems approach to air preparation Features Externally Monitored Safety Exhaust Valve Function When applications demand a safe environment
More informationCompact pressure switches for gas and air
Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The
More informationModel GP PRESSURE REDUCING VALVE Installation & Operation Manual
Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More informationPneumatic valve islands
Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented
More informationMaintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA
CT801-SI, CT801-TA Maintenance Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Maintenance Manual CT801-SI, CT801-TA
More informationTANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR
SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE