Universal Charging and Testing Unit FPU-1

Size: px
Start display at page:

Download "Universal Charging and Testing Unit FPU-1"

Transcription

1 1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose the charging and testing unit is screwed onto the gas valve of the hydraulic accumulator and connected to a commercial nitrogen bottle via a flexible charging hose. If the nitrogen pressure is only to be checked or reduced, the charging hose does not need to be connected. The unit has a screw-type fitting with a built-in gauge, check valve and a spindle for opening the accumulator gas valve to control the pressure. HYDAC piston and diaphragm accumulators can be charged and checked without the need for adaptors. Bladder accumulators, however, require an adaptor (A3 supplied as standard, see model code on page 2). Universal Charging and Testing Unit FPU-1 For Bladder, Piston and Diaphragm Accumulators

2 1.2. INTERVALS BETWEEN CHECKING On the whole, nitrogen losses on HYDAC hydraulic accumulators are very low. However, a regular check of the gas pre-charge pressure is recommended to prevent the piston from hitting the cover plate or the bladder or diaphragm from becoming too deformed, if there is a drop in the pressure p 0. The pre-charge pressure p 0 as shown on the label or the accumulator body, must be re-set after every new installation or repair and then checked at least once during the following week. If no nitrogen loss is detected, a further check should be made after approx. 4 months. If after this period no change in the pressure is found, a yearly check should be sufficient CONSTRUCTION The HYDAC charging and testing unit for bladder, piston and diaphragm accumulators consists of: Valve body Spindle Check valve Release valve Gauge Charging hose A3 adaptor for bladder accumulators 1.4. ACCESSORIES Gas safety valve with intermediate piece TUV set and lead sealed, it must be fitted between the hydraulic accumulator and the nitrogen bottle by means of the intermediate piece, if the gas pressure in the commercially available nitrogen bottle is higher than the max. permissible operating pressure of the hydraulic accumulator. Pressure reducer for setting the required pre-charge pressure between nitrogen bottle and accumulator. Protective case for storing the charging and testing unit and adaptors. 2. TECHNICAL SPECIFICATIONS 2.1. MODEL CODE (also order example) Universal charging and testing unit Gauge indication range 0-10 bar psi bar psi bar psi bar psi bar psi 400 Charging hose F = for 200 bar nitrogen bottle with connection W24.32 x 1/14 (DIN 477, Part 1) FM = for 300 bar nitrogen bottle with connection M30 x 1.5 (DIN 477, Part 5) FW = for 300 bar nitrogen bottle with connection W30 x 2 (CEN) Length of charging hose 2.5 m m 4 Special lengths on request Adaptor G for nitrogen bottles See table under point 10 (page 15) Adaptor A A1 = M16 x 1.5 A2 = 5/8-18 UNF A3 = 7/8-14 UNF A4 = 7/8-14 UNF A5 = M8 x 1 A6 = G 3/4 A A7 = G 1/4 A8 = G 3/4 A9 = Vg 8 A10 = 7/8 14 UNF A11 = M16 x 2 D4 = 5/8-18 UNF (Material no ) other adaptors on request Protective case (A3 is supplied as standard) Accessories (Please give full details when ordering.) Gas safety valve with intermediate piece (see point 5.3.). Pressure reducer (see point 5.1.). Adaptor for connector D (see point 4.1.). Wrench 14x15 (material no ). Allen key SW6 (material no ). Valve tool for gas valve (material no ) WEIGHT Standard model without case: approx. 1.4 kg Standard model with case: approx. 3.0 kg FPU F 2.5 G2 A1 K Different types of case are available, depending on customer requirement. 2

3 2.3. FPU-1 STANDARD MODELS Model without case Model code Material no. FPU-1-010F2.5A FPU-1-025F2.5A FPU-1-100F2.5A FPU-1-250F2.5A FPU-1-400F2.5A FPU-1-010F4A FPU-1-025F4A FPU-1-100F4A FPU-1-250F4A FPU-1-400F4A Model with case Model code Material no. FPU-1-010F2.5A3K FPU-1-025F2.5A3K FPU-1-100F2.5A3K FPU-1-250F2.5A3K FPU-1-400F2.5A3K FPU-1-010F4A3K FPU-1-025F4A3K FPU-1-100F4A3K FPU-1-250F4A3K FPU-1-400F4A3K Model without case with G adaptor Model code Material no. FPU-1-250F2.5G2A FPU-1-250F2.5G3A FPU-1-250F2.5G4A FPU-1-250F2.5G9A FPU-1-250F4G3A FPU-1-250F4G6A FPU-1-250F4G10A FPU-1-400F2.5G2A FPU-1-400F2.5G3A FPU-1-400F2.5G8A Model with case and G adaptor Model code Material no. FPU-1-010F2.5G2A3K FPU-1-010F2.5G3A3K FPU-1-010F2.5G4A3K FPU-1-010F2.5G6A3K FPU-1-010F2.5G7A3K FPU-1-010F2.5G8A3K FPU-1-010F2.5G9A3K FPU-1-010F2.5G10A3K FPU-1-010F4G7A3K FPU-1-025F2.5G2A3K FPU-1-025F2.5G3A3K FPU-1-025F2.5G4A3K FPU-1-025F2.5G5A3K FPU-1-025F2.5G8A3K FPU-1-025F2.5G9A3K FPU-1-025F2.5G10A3K FPU-1-025F4G9A3K FPU-1-100F2.5G2A3K FPU-1-100F2.5G4A3K FPU-1-100F2.5G6A3K FPU-1-100F2.5G9A3K FPU-1-100F4G3A3K FPU-1-250F2.5G2A3K FPU-1-250F2.5G3A3K FPU-1-250F2.5G4A3K FPU-1-250F2.5G5A3K FPU-1-250F2.5G6A3K FPU-1-250F2.5G7A3K FPU-1-250F2.5G8A3K FPU-1-250F2.5G9A3K FPU-1-250F4G2A3K FPU-1-250F4G3A3K FPU-1-250F4G4A3K FPU-1-250F4G8A3K FPU-1-250F4G9A3K FPU-1-250F4G10A3K FPU-1-400F2.5G2A3K FPU-1-400F2.5G3A3K FPU-1-400F2.5G4A3K FPU-1-400F2.5G5A3K FPU-1-400F2.5G6A3K FPU-1-400F2.5G8A3K FPU-1-400F2.5G9A3K FPU-1-400F4G2A3K FPU-1-400F4G3A3K FPU-1-400F4G7A3K FPU-1-400F4G8A3K FPU-1-400F4G9A3K FPU-1-400F4G10A3K SPECIAL MODELS For pressures exceeding 400 bar, the following special models are available: FPS 600 for bladder accumulators up to 600 bar max. pre-charge pressure (see technical information ). FPK 600 for piston, diaphragm and SB accumulators up to 600 bar max. pre-charge pressure (see technical information ). FPH 800 for high pressure bladder accumulators up to 800 bar max. pre-charge pressure (see technical information ). 3

4 3. OPERATING INSTRUCTIONS 3.1. TAKING ACCOUNT OF THE TEMPERATURE EFFECT In order that the recommended pre-charge pressures are maintained even at relatively high operating temperatures, the precharge pressure p 0 charge for charging and testing a cold accumulator must be selected as follows: p 0 charge = p 0 Pre-charge temp Operating temp Pre-charge temperature [ C] Operating temperature [ C] 3.2. PREPARATION Prior to each testing, topping-up or re-charging of nitrogen, the accumulator must be isolated from the pressurised system by means of a shut-off valve and the fluid released. Unscrew the protective caps S and H (only on bladder accumulators). Remove the O-ring O on bladder accumulators. Slightly loosen the internal hexagon screw P on piston and diaphragm accumulators by means of an Allen key SW 6, DIN 911 (approx. ½ turn). Place FPU-1 onto the accumulator and screw connector D by hand onto accumulator gas valve. At the same time, ensure that the release B of the FPU-1 is closed. Turn charging unit to a position where the gauge can be easily read TESTING On bladder accumulators (FPU-1 with A3 or other suitable adaptor) open valve by turning spindle A clockwise. On piston and diaphragm accumulators (FPU-1) open valve V by turning the internal hexagon screw anticlockwise with spindle A. When the needle of the gauge begins to move, give the spindle another complete turn. The gauge now shows the charging pressure in the accumulator. The check valve C prevents any escape of nitrogen REDUCING THE PRE-CHARGE PRESSURE Carefully open release B. The nitrogen escapes into the atmosphere. B A D Charging and testing unit FPU-1 for piston and diaphragm accumulators Allen key SW 6 DIN 911 Gas valve for piston and diaphragm accumulators C B A A3 Charging and testing unit for bladder accumulators with adaptor A3 Gas valve for bladder accumulators C 4

5 3.5. INCREASING PRE-CHARGE PRESSURE Only use nitrogen for charging accumulators Never use oxygen! Danger of explosion! If the gas pressure in the nitrogen bottle is higher than the max. operating pressure of the accumulator, a gas pressure reducer must be fitted. Connect the flexible charging hose to the pressure reducer on the nitrogen bottle by means of the connector G1. For nitrogen bottles from other countries the appropriate adaptor is required (see page 15). Connect connector M of the charging hose to the check valve C of the charging and testing unit FPU-1. Open the shut-off valve on the nitrogen bottle, and slowly release nitrogen into the accumulator. Wait until approximately 1 bar has been reached before opening the shutoff valve of the nitrogen bottle further to enable faster charging. Interrupt the charging process from time to time and check the pre-charge pressure reached. Repeat this process until the required gas pre-charge pressure is achieved. After temperature equalisation has taken place, re-check the pre-charge pressure and adjust if necessary. If the pressure is too high, it can be lowered via the pressure release B of the FPU-1. If the required gas pre-charge pressure has been reached, turn the spindle anticlockwise to close the gas valve on bladder accumulators. On piston or diaphragm accumulators close the internal hexagon screw P by turning the spindle clockwise. Discharge the charging and testing unit FPU-1 via the pressure release and remove it by loosening the connector. On bladder accumulators, unscrew the adaptor and replace the O-ring O. On piston and diaphragm accumulators, tighten the internal hexagon screw P with Allen key [20 Nm]. Check for leakages on the accumulator gas valve using a leak detector spray. Screw on cap nut H (only on bladder accumulators) and valve protection cap S onto the gas valve of the accumulator and tighten FPU-1 WITH ACCESSORIES adaptor G pressure reducer G 1 charging hose nitrogen bottle 3.7. WARNING Nitrogen and operating fluid can escape when filling or testing the accumulator due to a faulty, i.e. leaking, bladder, diaphragm or piston seals. Caution! Risk to health in the case of aggressive fluids! (special charging and testing unit available on request) The check valve C must not be dismantled. The valve has a safety function for the whole charging and testing unit. charging and testing unit FPU-1 M adaptor A hydraulic accumulator 5

6 4. DIMENSIONS 4.1. CHARGING AND TESTING UNIT FPU-1 WITH ADAPTOR FOR HYDAC ACCUMULATORS Bladder accumulator / Bladder accumulator 1l Gas valve to ISO Piston and diaphragm accumulator 6

7 4.2. CHARGING HOSE F (200 bar nitrogen bottle - connection to DIN 477, part 1) Length Material no. 2.5 m m m m m m Charging hoses are suitable for the respective published maximum permissible operating pressures and 10,000 charging processes. (HYDAC charging hoses comply with the EC machine directive and with DIN EN 982 and DIN EN 853 to 857) CHARGING HOSE FM (300 bar nitrogen bottle - connection to DIN 477, part 5) Length Material no. 2.5 m m CHARGING HOSE FW (300 bar nitrogen bottle - connection to CEN) Length Material no. 2.5 m m knurling 7

8 4.5. ADAPTORS A1 TO A11 The universality of the FPU-1 is guaranteed because as well as HYDAC piston and diaphragm accumulators, bladder accumulators can also be charged and tested using the A3 adaptor. By using additional adaptors other makes of accumulator can also be charged and tested. A1 (Material no ) A4 (Material no ) A2 (Material no ) A5 (Material no ) A3 (Material no ) A6 (Material no ) 8

9 A7 (Material no ) 4.6. ADAPTORS G2 TO G11 G 7 (Material no ) G 2 (Material no ) seal ring A 6 x 10 A8 (Material no ) G 8 (Material no ) G 3 (Material no ) A9 (Material no ) G 9 (Material no ) G 4 (Material no ) seal ring A 6 x 10 seal ring A 6 x 10 A10 (Material no ) G 5 (Material no ) G 10 (Material no ) seal ring A 6 x 10 A11 (Material no ) G 6 (Material no ) G 11 (Material no ) seal ring A 6 x 10 seal ring A 6 x 10 9

10 5. ACCESSORIES 5.1. PRESSURE REDUCER FOR 200 BAR NITROGEN BOTTLES (Connection W24.32 x 1/14 - DIN 477, Part 1) Bottle pressure Reduces pressure [bar] to between [bar] Material no Weight: 2.3 kg 5.2. PRESSURE REDUCER FOR 300 BAR NITROGEN BOTTLES (Connection W30 x 2 - CEN) approx. Bottle pressure Reduces pressure Connection H Material no. [bar] to between [bar] W24.32x1/ W24.32x1/ W24.32x1/ Weight: 2.3 kg 10

11 5.3. GAS SAFETY VALVE GSV6 hex. 32 GSV EN ISO G.195 KG/H 330 BAR TS -20/80 C PS 370 BAR 14/03/452 Steel/elastomer sealing ring TÜV / HYDAC seal Model code (also ordering example) GSV CE0034.ENISO G Gas safety valve Component code Flow rate Q in kg/h (see table, point 5.3.2) Pressure setting p in bar (see table, point 5.3.2) Types of GSV Type of construction Q [kg/h] p [bar] Mat. no others on request > 350 bar = additional price for EC individual testing Direct-acting gas safety valve nominal width 6 mm Design PED 97/23/EC, EN ISO , EN Others on request Module category IV to PED 97/23/EC Module B + D (EC prototype test) module G (EC individual test) on request Materials stainless steel, closing element with flexible seat seal Operating pressure range 30 to 370 bar Temperature range -20 to +80 C Operating fluid Nitrogen (N 2 ) Mounting position optional Weight 1.1 kg 11

12 5.4. INTERMEDIATE PIECE GSV6-10-CE Intermediate piece for fitting the gas safety valve GSV6 between the 200 bar nitrogen bottle and the charging and testing unit FPU-1 (material no ) Weight: 0.5 kg 6. CHARGING AND TESTING BLOCK F + P The HYDAC charging and testing block F+P is used to charge and test back-up type hydraulic accumulators. It has connections for the charging and testing unit FPU-1 and for pressure gauges. As a safety function, a gas safety valve GSV6 can be fitted. In addition it allows the back-up nitrogen bottles to be shut off from the hydraulic accumulator BACK-UP TYPE HYDRAULIC ACCUMULATOR WITH CHARGING AND TESTING BLOCK connection for charging and testing unit FPU-1 connection for gas safety valve charging and testing block nitrogen bottles hydraulic accumulator safety and shut-off block 12

13 6.2. CHARGING AND TESTING BLOCK DN 16 charging and testing unit M28 x mounting holes hydraulic accumulator nitrogen bottle gas safety valve GSV6 (optional) connection for pressure gauge (optional) connection for pressure gauge (optional) F+P-16-20SR X (Material no ) (max. operating pressure 400 bar) Weight: 4.3 kg 6.3. CHARGING AND TESTING BLOCK DN 32 charging and testing unit M28 x mounting holes hydraulic accumulator nitrogen bottle connection for pressure gauge (optional) gas safety valve GSV6 (optional) connection for pressure gauge (optional) F+P-32-38SR X (Material no ) (max. operating pressure 350 bar) Weight: 14.0 kg 13

14 7. SPARE PARTS CHARGING AND TESTING UNIT FPU-1 Item Quantity Designation Material no. 1 1 O-ring 6 x Seal ring Pressure 0-10 bar gauge 0-25 bar bar bar bar O-ring 15 x Seal ring O-ring 11 x O-ring 9 x O-ring 11 x O-ring 5.7 x Seal kit FPU GAS SAFETY VALVE GSV6-10-CE Item Quantity Designation Material no. 11 Seal ring x x When mounting onto the HYDAC charging and testing block, O-ring 18 x 2.5 (Material no ) must be fitted. INTERMEDIATE PIECE GSV6-10-CE Item Quantity Designation Material no O-ring 20 x Seal ring 20 x 11.5 x Seal ring 14 x 8.5 x Seal kit intermediate piece CHARGING AND TESTING BLOCK Seal kit F+P DN Seal kit F+P DN NITROGEN CHARGING UNIT HYDAC nitrogen charging units facilitate fast and cost-effective filling or testing of the required gas pre-charge pressure in bladder, diaphragm or piston accumulators. They guarantee optimum use of commercially available nitrogen bottles up to a residual pressure of 20 bar and a maximum accumulator pressure of 350 bar. Portable, mobile and stationary types of N 2 Server are available. For further details and technical specifications, see HYDAC brochure "Nitrogen Charging Unit N 2 Server", no.: E NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 14

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Hydraulic Accumulators with Back-Up Nitrogen Bottles Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with

More information

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable Page 1 von 8 Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV 100-575, top reparable Content Seite 0 Legend 2 1 Overview 2 2 Accumulator assembly and installation

More information

Diaphragm Accumulators

Diaphragm Accumulators 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

Diaphragm accumulator type AC

Diaphragm accumulator type AC Diaphragm accumulator type AC Max. operating pressure pmax: Max. nom. volume VO max: 350 bar 2.8 dm3 Symbol: Product documentation D 7969 AC 04-2014-1.1 HAWE Hydraulik SE - Streitfeldstr. 25 81673 München

More information

Operating Instructions UCA Charging & Gauging Kit. For use with Piston, Bladder & Diaphragm Accumulators. Hydraulics. Effective: 01 July 2001

Operating Instructions UCA Charging & Gauging Kit. For use with Piston, Bladder & Diaphragm Accumulators. Hydraulics. Effective: 01 July 2001 Operating Instructions Charging & Gauging Kit Effective: 01 July 2001 For use with Piston, Bladder & Diaphragm Accumulators Warning FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR

More information

Diaphragm accumulator type AC

Diaphragm accumulator type AC Diaphragm accumulator type AC Product documentation Operating pressure pmax: 350 bar Capacity V0 max: 2.8 dm 3 D 7969 04-2014-1.7 by HAWE Hydraulik SE. The reproduction and distribution of this document

More information

Hydraulic Piston Accumulators

Hydraulic Piston Accumulators Hydraulic Installation All accumulators shipped from the factory will be pre-charged to a nominal pressure in order to seat the piston on the hydraulic cap. In this case the precharge will not be listed

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. Description 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

Bladder Accumulators High pressure

Bladder Accumulators High pressure Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in

More information

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators. It complies with the relevant safety standards

More information

STAINLESS STEEL OVERFLOW VALVE TYPE 417

STAINLESS STEEL OVERFLOW VALVE TYPE 417 MAIN CHARACTERISTICS The 417 valve is intended for the discharge of fluids overflow when an upstream limitation of pressure is looked for, for example downstream to a pump. This valve also works in presence

More information

HYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION FUNCTION CONSTRUCTION MOUNTING POSITION TYPE OF MOUNTING 3 2. APPLIC

HYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION FUNCTION CONSTRUCTION MOUNTING POSITION TYPE OF MOUNTING 3 2. APPLIC Bladder Accumulators HYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION 3 1.1. FUNCTION 3 1.2. CONSTRUCTION 3 1.3. MOUNTING POSITION 3 1.4. TYPE OF MOUNTING 3 2. APPLICATIONS 4 2.1. TYPICAL APPLICATIONS

More information

Two-stage valve type NE

Two-stage valve type NE Two-stage valve type NE Product documentation Operating pressure pmax: Flow rate Qmax: 700 bar (High pressure) 80 bar (Low pressure) 25 lpm (High pressure) 180 lpm (Low pressure) D 7161 03-2017-1.0 by

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators HYDAC Diaphragm Accumulators Index Page 1. Description 3 Introduction 3 Construction 3 2. Applications 4 3. Technical Data 6 Operation 6 Technical Specifications 6 Temperature Effect

More information

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 750 set range: bar Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long

More information

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E

Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Table of content 1. General information on installation, operating and maintenance instructions 1.1 Hazard notices 1.2 Qualified

More information

HYDRAULIC & LUBE OIL UNIT EQUIPMENTS

HYDRAULIC & LUBE OIL UNIT EQUIPMENTS HYDRAULIC AND PROCESS TECHNOLOGY HYDRAULIC & LUBE OIL UNIT EQUIPMENTS Bladder Accumulators Rev.0 BLADDER ACCUMULATORS General operation procedure A) A flexible separator bladder is fitted into a pressure

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

for for Industrial Refrigeration

for for Industrial Refrigeration Catalogue Shut-off Safety relief and regulating valves valves for for Industrial Refrigeration Contents Page Safety relief valves, type SFA 15 and SFA 15-50....3 Safety relief valves, type SFV 20-25....

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven

More information

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Multi-way diverting valves Series 29a and Series 29b, with packing with lever 1. The valves are

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

PV4 and PV6 Piston Valves

PV4 and PV6 Piston Valves 1181250/1 IM-P118-05 ST Issue 1 PV4 and PV6 Piston Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6.

More information

Safety Relief Valve HON 832

Safety Relief Valve HON 832 Safety Relief Valve HON 832 product information serving the gas industry worldwide Application, characteristics, technical data Application 2 As leak gas SRV with internal vent connection (function class

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

SB 102. Spare parts list. Hydraulic breakers. SB 102 s/n BES Construction Tools PC AB No h

SB 102. Spare parts list. Hydraulic breakers. SB 102 s/n BES Construction Tools PC AB No h SB 102 Spare parts list Hydraulic breakers SB 102 s/n BES043603 2018 Construction Tools PC AB No. 9800064201h 2018-01 General information This spare parts list applies to the following: Part number 8460030030

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Overview of types.   T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2) Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for storing

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes Technical data sheet R2..-S.. Open-close ball valves, 2-way, with internal thread For open and closed cold and warm water systems For shut-off functions on the water side and 2-point controls in U and

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media

More information

Regulators repair and maintenance. 1st stage MC5. MC5 INT HZ MC5 DIN 300 bar HZ

Regulators repair and maintenance. 1st stage MC5. MC5 INT HZ MC5 DIN 300 bar HZ 1st stage MC5 MC5 INT HZ 800098 MC5 DIN 300 bar HZ 800099 January 2008 Rev. MC5 / 1 Ed. A / 08 1 1st stage MC5 WARNING! This document is intended for experienced technical personnel who have already attended

More information

SB 152. Spare parts list. Hydraulic breakers. SB 152 s/n BES Construction Tools PC AB No

SB 152. Spare parts list. Hydraulic breakers. SB 152 s/n BES Construction Tools PC AB No SB 152 Spare parts list Hydraulic breakers SB 152 s/n BES043707 2018 Construction Tools PC AB No. 9800041001 2018-01 General information This spare parts list applies to the following: Part number 8460030040

More information

Connection solutions for the gas industry Date: 04/2013

Connection solutions for the gas industry Date: 04/2013 Catalogue 20 WEH Connectors Pressure-tight connections in seconds for gaseous applications Connection solutions for the gas industry Date: 04/2013 WEH - We Engineer Hightech All rights reserved, WEH GmbH

More information

Hydraulic Piston Accumulators

Hydraulic Piston Accumulators Ride Control Engineering Services PWCE Extendavator Paul Wever Construction Equipment Co., Inc. P.O. Box 85 401 Martin Drive Goodfield, IL 61742-0085 Phone (309) 965-2005 Fax (309) 965-2905 1-800-990-PWCE

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0

More information

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Operating Manual LTIA3E Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

SB 452. Spare parts list. Hydraulic breakers. SB 452 s/n BES Construction Tools PC AB No h

SB 452. Spare parts list. Hydraulic breakers. SB 452 s/n BES Construction Tools PC AB No h SB 452 Spare parts list Hydraulic breakers SB 452 s/n BES043603 2018 Construction Tools PC AB No. 9800088701h 2018-01 General information This spare parts list applies to the following: Part number 8460030070

More information

SB 52. Spare parts list. Hydraulic breakers. SB 52 s/n BES Construction Tools PC AB No j

SB 52. Spare parts list. Hydraulic breakers. SB 52 s/n BES Construction Tools PC AB No j SB 52 Spare parts list Hydraulic breakers SB 52 s/n BES043707 2018 Construction Tools PC AB No. 9800069301j 2018-01 General information This spare parts list applies to the following: Part number 8460030010

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Gas Pressure Regulator HON 300

Gas Pressure Regulator HON 300 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction

More information

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully

More information

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Operating Manual LTIA5E Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical data

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

TURBO SET 1000 E D $'9 5(9

TURBO SET 1000 E D $'9 5(9 TURBO SET 1000 Instructions for use and maintenance HOW TO GAS WELD WITH TURBO SET 1000 With gas welding always work methodically : before starting a weld ensure that the parent metal in the weld area

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions 1234150/3 IM-P123-17 ST Issue 3 AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4.

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13 MC9 1 st Stage 137 1 st STAGE MC9 Jannuary 2009 - Rev. MC9 /B Ed. C/13 138 WARNING! This manual is intended for use by expert technicians who should attend or have already received training in equipment

More information

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions 1270750/7 IM-P127-02 ST Issue 7 UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions 1 General safety information 2 General

More information

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...

1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines... Table of Contents 1. Preface...1 2. Important Safety Notes...1 3. Brief Product Information...3 4. Product Working Principle...5 5. Installation Guidelines...6 6. Startup and Commissioning...8 7. Maintenance

More information

Pressure Reducing Valve DMV 750

Pressure Reducing Valve DMV 750 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

BLADDER CARE INSTRUCTIONS

BLADDER CARE INSTRUCTIONS BLADDER CARE INSTRUCTIONS BLADDER REPLACEMENT ACCUMULATOR PRECHARGING ACCUMULATOR PRECHARGE MAINTENANCE ACCUMULATOR COMMISSIONING (For 3000, 4000, 5000, 6000 and 6500-psi Accumulators) (Does not apply

More information

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU FAS Straight-Way Valve with Packing Gland Please read these operating instructions carefully to ensure a safe operation

More information

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw. Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces

More information

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012 Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of

More information

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual Instruction Manual Alfa Laval SB Pressure Exhaust Valve ESE02965-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Continuous, inline sampling valves Series 27f, with packing Operate with either; Star lever, or

More information

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 725 set range: 0,2-10,0 bar Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level

More information

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long

More information

Pilot Operated Pressure Reducing Valve

Pilot Operated Pressure Reducing Valve OPTIONS: USE: Pilot Operated Pressure Reducing Valve Steam & Compressed Air PRV 37 (DN15-DN50) DESCRIPTION The ADCA PRV37 pilot operated pressure reducing valves are designed for use on steam, compressed

More information

Safety valves. Component-tested safety valves DN Compressed Air Accessories II Hoses, valves etc. 15. Technical data. Exhaust capacity air

Safety valves. Component-tested safety valves DN Compressed Air Accessories II Hoses, valves etc. 15. Technical data. Exhaust capacity air Component-tested s DN 6 Safety valves serve to blow out non-poisonous and non flammable gases into the atmosphere in order to protect pressure tanks against overpressure. Please note: Only s that have

More information

OXYWAY. Service and Repair Instructions

OXYWAY. Service and Repair Instructions OXYWAY Single-stage pressure reducer, fixed: Fix I; Fix I side outlet; Fix II; Fix III; Fix III left Single-stage pressure reducer, variable: Fine I; Fine II; Fine III Single-stage pressure reducer, indexed:

More information

Safety relief valves SFV 20-25

Safety relief valves SFV 20-25 MAKING MODERN LIVING POSSIBLE Technical brochure Safety relief valves SFV 20-25 www.danfoss.com/ir Contents Page Introduction........................................................................................3

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification

More information

STAUFF Accumulators Accessories

STAUFF Accumulators Accessories Local Solutions For Individual Customers Worldwide STUFF ccumulators Clamps & Supports 28 Safety Blocks 30 Burst Discs 34 Fuse Discs 35 Replacement Back-up Bottles 36 Clamps & Supports ccumulator Clamps

More information

BCV31 DN40 - Blowdown Control Valve

BCV31 DN40 - Blowdown Control Valve 4034850/5 IM-P403-71 AB Issue 5 BCV31 DN40 - Blowdown Control Valve Installation and Maintenance Instructions 1. Safety information 2. Application 3. Technical data 4. Operation 5. Installation 6. Flow

More information

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691 THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,

More information

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps Operating Instructions Models 36200, 362000, 46200, 462000 Hydrostatic Test Pumps 46200 DIMENSIONS: 28 (70cm) L x 24 (60cm) W x 38 (87.5cm) H WEIGHT: PUMP: ENGINE: CONTROL: GAUGE: DISCHARGE HOSE: INTAKE

More information

GAS PRESSURE CONTROL UNIT TYPE 132

GAS PRESSURE CONTROL UNIT TYPE 132 GAS PRESSURE CONTROL UNIT TYPE 132 OUR DIVERSITY IS YOUR PROFIT. Gas Pressure Regulator Type 132 Scope of Application Scope of type 132 gas pressure regulator is to maintain the output pressure at a constant

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

SBU 220. Spare parts list. Hydraulic breakers. SBU 220 s/n BES Construction Tools PC AB No

SBU 220. Spare parts list. Hydraulic breakers. SBU 220 s/n BES Construction Tools PC AB No SBU 220 Spare parts list Hydraulic breakers SBU 220 s/n BES090753 2018 Construction Tools PC AB No. 9800097101 2018-01 General information This spare parts list applies to the following: Part number Description

More information

Horne Engineering Ltd

Horne Engineering Ltd Horne Engineering Ltd Po Box 7, Rankine Street Johnstone, Renfrewshire Scotland, PA5 8BD Tel: 01505 321455 Fax: 01505 336287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE T105A/106A/107A/108A

More information

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 3/2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without notice.

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES

CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES Sampling Valves Installation Commissioning and Operating Instructions SD IL 300 & SD IL 400 Inline Sampling Valve This

More information

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Page 1 of 15 Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Model Number A25-XXXX-3.6K Series A40-XXXX-3K Series A40X-XXXX-3.6K Series A60-XXXX-3K

More information