1 1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose the charging and testing unit is screwed onto the gas valve of the hydraulic accumulator and connected to a commercial nitrogen bottle via a flexible charging hose. If the nitrogen pressure is only to be checked or reduced, the charging hose does not need to be connected. The unit has a screw-type fitting with a built-in gauge, check valve and a spindle for opening the accumulator gas valve to control the pressure. HYDAC piston and diaphragm accumulators can be charged and checked without the need for adaptors. Bladder accumulators, however, require an adaptor (A3 supplied as standard, see model code on page 2). Universal Charging and Testing Unit FPU-1 For Bladder, Piston and Diaphragm Accumulators
2 1.2. INTERVALS BETWEEN CHECKING On the whole, nitrogen losses on HYDAC hydraulic accumulators are very low. However, a regular check of the gas pre-charge pressure is recommended to prevent the piston from hitting the cover plate or the bladder or diaphragm from becoming too deformed, if there is a drop in the pressure p 0. The pre-charge pressure p 0 as shown on the label or the accumulator body, must be re-set after every new installation or repair and then checked at least once during the following week. If no nitrogen loss is detected, a further check should be made after approx. 4 months. If after this period no change in the pressure is found, a yearly check should be sufficient CONSTRUCTION The HYDAC charging and testing unit for bladder, piston and diaphragm accumulators consists of: Valve body Spindle Check valve Release valve Gauge Charging hose A3 adaptor for bladder accumulators 1.4. ACCESSORIES Gas safety valve with intermediate piece TUV set and lead sealed, it must be fitted between the hydraulic accumulator and the nitrogen bottle by means of the intermediate piece, if the gas pressure in the commercially available nitrogen bottle is higher than the max. permissible operating pressure of the hydraulic accumulator. Pressure reducer for setting the required pre-charge pressure between nitrogen bottle and accumulator. Protective case for storing the charging and testing unit and adaptors. 2. TECHNICAL SPECIFICATIONS 2.1. MODEL CODE (also order example) Universal charging and testing unit Gauge indication range 0-10 bar psi bar psi bar psi bar psi bar psi 400 Charging hose F = for 200 bar nitrogen bottle with connection W24.32 x 1/14 (DIN 477, Part 1) FM = for 300 bar nitrogen bottle with connection M30 x 1.5 (DIN 477, Part 5) FW = for 300 bar nitrogen bottle with connection W30 x 2 (CEN) Length of charging hose 2.5 m m 4 Special lengths on request Adaptor G for nitrogen bottles See table under point 10 (page 15) Adaptor A A1 = M16 x 1.5 A2 = 5/8-18 UNF A3 = 7/8-14 UNF A4 = 7/8-14 UNF A5 = M8 x 1 A6 = G 3/4 A A7 = G 1/4 A8 = G 3/4 A9 = Vg 8 A10 = 7/8 14 UNF A11 = M16 x 2 D4 = 5/8-18 UNF (Material no ) other adaptors on request Protective case (A3 is supplied as standard) Accessories (Please give full details when ordering.) Gas safety valve with intermediate piece (see point 5.3.). Pressure reducer (see point 5.1.). Adaptor for connector D (see point 4.1.). Wrench 14x15 (material no ). Allen key SW6 (material no ). Valve tool for gas valve (material no ) WEIGHT Standard model without case: approx. 1.4 kg Standard model with case: approx. 3.0 kg FPU F 2.5 G2 A1 K Different types of case are available, depending on customer requirement. 2
3 2.3. FPU-1 STANDARD MODELS Model without case Model code Material no. FPU-1-010F2.5A FPU-1-025F2.5A FPU-1-100F2.5A FPU-1-250F2.5A FPU-1-400F2.5A FPU-1-010F4A FPU-1-025F4A FPU-1-100F4A FPU-1-250F4A FPU-1-400F4A Model with case Model code Material no. FPU-1-010F2.5A3K FPU-1-025F2.5A3K FPU-1-100F2.5A3K FPU-1-250F2.5A3K FPU-1-400F2.5A3K FPU-1-010F4A3K FPU-1-025F4A3K FPU-1-100F4A3K FPU-1-250F4A3K FPU-1-400F4A3K Model without case with G adaptor Model code Material no. FPU-1-250F2.5G2A FPU-1-250F2.5G3A FPU-1-250F2.5G4A FPU-1-250F2.5G9A FPU-1-250F4G3A FPU-1-250F4G6A FPU-1-250F4G10A FPU-1-400F2.5G2A FPU-1-400F2.5G3A FPU-1-400F2.5G8A Model with case and G adaptor Model code Material no. FPU-1-010F2.5G2A3K FPU-1-010F2.5G3A3K FPU-1-010F2.5G4A3K FPU-1-010F2.5G6A3K FPU-1-010F2.5G7A3K FPU-1-010F2.5G8A3K FPU-1-010F2.5G9A3K FPU-1-010F2.5G10A3K FPU-1-010F4G7A3K FPU-1-025F2.5G2A3K FPU-1-025F2.5G3A3K FPU-1-025F2.5G4A3K FPU-1-025F2.5G5A3K FPU-1-025F2.5G8A3K FPU-1-025F2.5G9A3K FPU-1-025F2.5G10A3K FPU-1-025F4G9A3K FPU-1-100F2.5G2A3K FPU-1-100F2.5G4A3K FPU-1-100F2.5G6A3K FPU-1-100F2.5G9A3K FPU-1-100F4G3A3K FPU-1-250F2.5G2A3K FPU-1-250F2.5G3A3K FPU-1-250F2.5G4A3K FPU-1-250F2.5G5A3K FPU-1-250F2.5G6A3K FPU-1-250F2.5G7A3K FPU-1-250F2.5G8A3K FPU-1-250F2.5G9A3K FPU-1-250F4G2A3K FPU-1-250F4G3A3K FPU-1-250F4G4A3K FPU-1-250F4G8A3K FPU-1-250F4G9A3K FPU-1-250F4G10A3K FPU-1-400F2.5G2A3K FPU-1-400F2.5G3A3K FPU-1-400F2.5G4A3K FPU-1-400F2.5G5A3K FPU-1-400F2.5G6A3K FPU-1-400F2.5G8A3K FPU-1-400F2.5G9A3K FPU-1-400F4G2A3K FPU-1-400F4G3A3K FPU-1-400F4G7A3K FPU-1-400F4G8A3K FPU-1-400F4G9A3K FPU-1-400F4G10A3K SPECIAL MODELS For pressures exceeding 400 bar, the following special models are available: FPS 600 for bladder accumulators up to 600 bar max. pre-charge pressure (see technical information ). FPK 600 for piston, diaphragm and SB accumulators up to 600 bar max. pre-charge pressure (see technical information ). FPH 800 for high pressure bladder accumulators up to 800 bar max. pre-charge pressure (see technical information ). 3
4 3. OPERATING INSTRUCTIONS 3.1. TAKING ACCOUNT OF THE TEMPERATURE EFFECT In order that the recommended pre-charge pressures are maintained even at relatively high operating temperatures, the precharge pressure p 0 charge for charging and testing a cold accumulator must be selected as follows: p 0 charge = p 0 Pre-charge temp Operating temp Pre-charge temperature [ C] Operating temperature [ C] 3.2. PREPARATION Prior to each testing, topping-up or re-charging of nitrogen, the accumulator must be isolated from the pressurised system by means of a shut-off valve and the fluid released. Unscrew the protective caps S and H (only on bladder accumulators). Remove the O-ring O on bladder accumulators. Slightly loosen the internal hexagon screw P on piston and diaphragm accumulators by means of an Allen key SW 6, DIN 911 (approx. ½ turn). Place FPU-1 onto the accumulator and screw connector D by hand onto accumulator gas valve. At the same time, ensure that the release B of the FPU-1 is closed. Turn charging unit to a position where the gauge can be easily read TESTING On bladder accumulators (FPU-1 with A3 or other suitable adaptor) open valve by turning spindle A clockwise. On piston and diaphragm accumulators (FPU-1) open valve V by turning the internal hexagon screw anticlockwise with spindle A. When the needle of the gauge begins to move, give the spindle another complete turn. The gauge now shows the charging pressure in the accumulator. The check valve C prevents any escape of nitrogen REDUCING THE PRE-CHARGE PRESSURE Carefully open release B. The nitrogen escapes into the atmosphere. B A D Charging and testing unit FPU-1 for piston and diaphragm accumulators Allen key SW 6 DIN 911 Gas valve for piston and diaphragm accumulators C B A A3 Charging and testing unit for bladder accumulators with adaptor A3 Gas valve for bladder accumulators C 4
5 3.5. INCREASING PRE-CHARGE PRESSURE Only use nitrogen for charging accumulators Never use oxygen! Danger of explosion! If the gas pressure in the nitrogen bottle is higher than the max. operating pressure of the accumulator, a gas pressure reducer must be fitted. Connect the flexible charging hose to the pressure reducer on the nitrogen bottle by means of the connector G1. For nitrogen bottles from other countries the appropriate adaptor is required (see page 15). Connect connector M of the charging hose to the check valve C of the charging and testing unit FPU-1. Open the shut-off valve on the nitrogen bottle, and slowly release nitrogen into the accumulator. Wait until approximately 1 bar has been reached before opening the shutoff valve of the nitrogen bottle further to enable faster charging. Interrupt the charging process from time to time and check the pre-charge pressure reached. Repeat this process until the required gas pre-charge pressure is achieved. After temperature equalisation has taken place, re-check the pre-charge pressure and adjust if necessary. If the pressure is too high, it can be lowered via the pressure release B of the FPU-1. If the required gas pre-charge pressure has been reached, turn the spindle anticlockwise to close the gas valve on bladder accumulators. On piston or diaphragm accumulators close the internal hexagon screw P by turning the spindle clockwise. Discharge the charging and testing unit FPU-1 via the pressure release and remove it by loosening the connector. On bladder accumulators, unscrew the adaptor and replace the O-ring O. On piston and diaphragm accumulators, tighten the internal hexagon screw P with Allen key [20 Nm]. Check for leakages on the accumulator gas valve using a leak detector spray. Screw on cap nut H (only on bladder accumulators) and valve protection cap S onto the gas valve of the accumulator and tighten FPU-1 WITH ACCESSORIES adaptor G pressure reducer G 1 charging hose nitrogen bottle 3.7. WARNING Nitrogen and operating fluid can escape when filling or testing the accumulator due to a faulty, i.e. leaking, bladder, diaphragm or piston seals. Caution! Risk to health in the case of aggressive fluids! (special charging and testing unit available on request) The check valve C must not be dismantled. The valve has a safety function for the whole charging and testing unit. charging and testing unit FPU-1 M adaptor A hydraulic accumulator 5
6 4. DIMENSIONS 4.1. CHARGING AND TESTING UNIT FPU-1 WITH ADAPTOR FOR HYDAC ACCUMULATORS Bladder accumulator / Bladder accumulator 1l Gas valve to ISO Piston and diaphragm accumulator 6
7 4.2. CHARGING HOSE F (200 bar nitrogen bottle - connection to DIN 477, part 1) Length Material no. 2.5 m m m m m m Charging hoses are suitable for the respective published maximum permissible operating pressures and 10,000 charging processes. (HYDAC charging hoses comply with the EC machine directive and with DIN EN 982 and DIN EN 853 to 857) CHARGING HOSE FM (300 bar nitrogen bottle - connection to DIN 477, part 5) Length Material no. 2.5 m m CHARGING HOSE FW (300 bar nitrogen bottle - connection to CEN) Length Material no. 2.5 m m knurling 7
8 4.5. ADAPTORS A1 TO A11 The universality of the FPU-1 is guaranteed because as well as HYDAC piston and diaphragm accumulators, bladder accumulators can also be charged and tested using the A3 adaptor. By using additional adaptors other makes of accumulator can also be charged and tested. A1 (Material no ) A4 (Material no ) A2 (Material no ) A5 (Material no ) A3 (Material no ) A6 (Material no ) 8
9 A7 (Material no ) 4.6. ADAPTORS G2 TO G11 G 7 (Material no ) G 2 (Material no ) seal ring A 6 x 10 A8 (Material no ) G 8 (Material no ) G 3 (Material no ) A9 (Material no ) G 9 (Material no ) G 4 (Material no ) seal ring A 6 x 10 seal ring A 6 x 10 A10 (Material no ) G 5 (Material no ) G 10 (Material no ) seal ring A 6 x 10 A11 (Material no ) G 6 (Material no ) G 11 (Material no ) seal ring A 6 x 10 seal ring A 6 x 10 9
10 5. ACCESSORIES 5.1. PRESSURE REDUCER FOR 200 BAR NITROGEN BOTTLES (Connection W24.32 x 1/14 - DIN 477, Part 1) Bottle pressure Reduces pressure [bar] to between [bar] Material no Weight: 2.3 kg 5.2. PRESSURE REDUCER FOR 300 BAR NITROGEN BOTTLES (Connection W30 x 2 - CEN) approx. Bottle pressure Reduces pressure Connection H Material no. [bar] to between [bar] W24.32x1/ W24.32x1/ W24.32x1/ Weight: 2.3 kg 10
11 5.3. GAS SAFETY VALVE GSV6 hex. 32 GSV EN ISO G.195 KG/H 330 BAR TS -20/80 C PS 370 BAR 14/03/452 Steel/elastomer sealing ring TÜV / HYDAC seal Model code (also ordering example) GSV CE0034.ENISO G Gas safety valve Component code Flow rate Q in kg/h (see table, point 5.3.2) Pressure setting p in bar (see table, point 5.3.2) Types of GSV Type of construction Q [kg/h] p [bar] Mat. no others on request > 350 bar = additional price for EC individual testing Direct-acting gas safety valve nominal width 6 mm Design PED 97/23/EC, EN ISO , EN Others on request Module category IV to PED 97/23/EC Module B + D (EC prototype test) module G (EC individual test) on request Materials stainless steel, closing element with flexible seat seal Operating pressure range 30 to 370 bar Temperature range -20 to +80 C Operating fluid Nitrogen (N 2 ) Mounting position optional Weight 1.1 kg 11
12 5.4. INTERMEDIATE PIECE GSV6-10-CE Intermediate piece for fitting the gas safety valve GSV6 between the 200 bar nitrogen bottle and the charging and testing unit FPU-1 (material no ) Weight: 0.5 kg 6. CHARGING AND TESTING BLOCK F + P The HYDAC charging and testing block F+P is used to charge and test back-up type hydraulic accumulators. It has connections for the charging and testing unit FPU-1 and for pressure gauges. As a safety function, a gas safety valve GSV6 can be fitted. In addition it allows the back-up nitrogen bottles to be shut off from the hydraulic accumulator BACK-UP TYPE HYDRAULIC ACCUMULATOR WITH CHARGING AND TESTING BLOCK connection for charging and testing unit FPU-1 connection for gas safety valve charging and testing block nitrogen bottles hydraulic accumulator safety and shut-off block 12
13 6.2. CHARGING AND TESTING BLOCK DN 16 charging and testing unit M28 x mounting holes hydraulic accumulator nitrogen bottle gas safety valve GSV6 (optional) connection for pressure gauge (optional) connection for pressure gauge (optional) F+P-16-20SR X (Material no ) (max. operating pressure 400 bar) Weight: 4.3 kg 6.3. CHARGING AND TESTING BLOCK DN 32 charging and testing unit M28 x mounting holes hydraulic accumulator nitrogen bottle connection for pressure gauge (optional) gas safety valve GSV6 (optional) connection for pressure gauge (optional) F+P-32-38SR X (Material no ) (max. operating pressure 350 bar) Weight: 14.0 kg 13
14 7. SPARE PARTS CHARGING AND TESTING UNIT FPU-1 Item Quantity Designation Material no. 1 1 O-ring 6 x Seal ring Pressure 0-10 bar gauge 0-25 bar bar bar bar O-ring 15 x Seal ring O-ring 11 x O-ring 9 x O-ring 11 x O-ring 5.7 x Seal kit FPU GAS SAFETY VALVE GSV6-10-CE Item Quantity Designation Material no. 11 Seal ring x x When mounting onto the HYDAC charging and testing block, O-ring 18 x 2.5 (Material no ) must be fitted. INTERMEDIATE PIECE GSV6-10-CE Item Quantity Designation Material no O-ring 20 x Seal ring 20 x 11.5 x Seal ring 14 x 8.5 x Seal kit intermediate piece CHARGING AND TESTING BLOCK Seal kit F+P DN Seal kit F+P DN NITROGEN CHARGING UNIT HYDAC nitrogen charging units facilitate fast and cost-effective filling or testing of the required gas pre-charge pressure in bladder, diaphragm or piston accumulators. They guarantee optimum use of commercially available nitrogen bottles up to a residual pressure of 20 bar and a maximum accumulator pressure of 350 bar. Portable, mobile and stationary types of N 2 Server are available. For further details and technical specifications, see HYDAC brochure "Nitrogen Charging Unit N 2 Server", no.: E NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 14
Hydraulic Accumulators with Back-Up Nitrogen Bottles
Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum
More informationSafety and Shut-off Block SAF/DSV
1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with
More informationAssembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable
Page 1 von 8 Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV 100-575, top reparable Content Seite 0 Legend 2 1 Overview 2 2 Accumulator assembly and installation
More informationDiaphragm Accumulators
1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies
More informationMounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator
Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering
More informationDiaphragm accumulator type AC
Diaphragm accumulator type AC Max. operating pressure pmax: Max. nom. volume VO max: 350 bar 2.8 dm3 Symbol: Product documentation D 7969 AC 04-2014-1.1 HAWE Hydraulik SE - Streitfeldstr. 25 81673 München
More informationOperating Instructions UCA Charging & Gauging Kit. For use with Piston, Bladder & Diaphragm Accumulators. Hydraulics. Effective: 01 July 2001
Operating Instructions Charging & Gauging Kit Effective: 01 July 2001 For use with Piston, Bladder & Diaphragm Accumulators Warning FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR
More informationDiaphragm accumulator type AC
Diaphragm accumulator type AC Product documentation Operating pressure pmax: 350 bar Capacity V0 max: 2.8 dm 3 D 7969 04-2014-1.7 by HAWE Hydraulik SE. The reproduction and distribution of this document
More informationHydraulic Piston Accumulators
Hydraulic Installation All accumulators shipped from the factory will be pre-charged to a nominal pressure in order to seat the piston on the hydraulic cap. In this case the precharge will not be listed
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. Description 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety
More informationBladder Accumulators High pressure
Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in
More informationHydraulic comparison test pump Models CPP1000-X, CPP1600-X
Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance
More informationMounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25
Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating
More informationSafety and Shut-off Block SAF/DSV
Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators. It complies with the relevant safety standards
More informationSTAINLESS STEEL OVERFLOW VALVE TYPE 417
MAIN CHARACTERISTICS The 417 valve is intended for the discharge of fluids overflow when an upstream limitation of pressure is looked for, for example downstream to a pump. This valve also works in presence
More informationHYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION FUNCTION CONSTRUCTION MOUNTING POSITION TYPE OF MOUNTING 3 2. APPLIC
Bladder Accumulators HYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION 3 1.1. FUNCTION 3 1.2. CONSTRUCTION 3 1.3. MOUNTING POSITION 3 1.4. TYPE OF MOUNTING 3 2. APPLICATIONS 4 2.1. TYPICAL APPLICATIONS
More informationTwo-stage valve type NE
Two-stage valve type NE Product documentation Operating pressure pmax: Flow rate Qmax: 700 bar (High pressure) 80 bar (Low pressure) 25 lpm (High pressure) 180 lpm (Low pressure) D 7161 03-2017-1.0 by
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationDiaphragm Accumulators
Diaphragm Accumulators HYDAC Diaphragm Accumulators Index Page 1. Description 3 Introduction 3 Construction 3 2. Applications 4 3. Technical Data 6 Operation 6 Technical Specifications 6 Temperature Effect
More informationPressure Reducing Valve DMV 750 set range: bar
Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long
More informationInstallation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E
Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Table of content 1. General information on installation, operating and maintenance instructions 1.1 Hazard notices 1.2 Qualified
More informationHYDRAULIC & LUBE OIL UNIT EQUIPMENTS
HYDRAULIC AND PROCESS TECHNOLOGY HYDRAULIC & LUBE OIL UNIT EQUIPMENTS Bladder Accumulators Rev.0 BLADDER ACCUMULATORS General operation procedure A) A flexible separator bladder is fitted into a pressure
More informationDiaphragm Accumulators
Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators
More informationfor for Industrial Refrigeration
Catalogue Shut-off Safety relief and regulating valves valves for for Industrial Refrigeration Contents Page Safety relief valves, type SFA 15 and SFA 15-50....3 Safety relief valves, type SFV 20-25....
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More information3-Way Safety Block DSV
3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with
More informationACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS
ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven
More informationPressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar
Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at
More informationDeclaration of Conformity as per Directive 97/23/EC
Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Multi-way diverting valves Series 29a and Series 29b, with packing with lever 1. The valves are
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationPV4 and PV6 Piston Valves
1181250/1 IM-P118-05 ST Issue 1 PV4 and PV6 Piston Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6.
More informationSafety Relief Valve HON 832
Safety Relief Valve HON 832 product information serving the gas industry worldwide Application, characteristics, technical data Application 2 As leak gas SRV with internal vent connection (function class
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationTHE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)
THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationPressure relief valve DHV 716 set range: 0,5-10,0 bar
Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of
More informationR133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid
R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder
More informationSB 102. Spare parts list. Hydraulic breakers. SB 102 s/n BES Construction Tools PC AB No h
SB 102 Spare parts list Hydraulic breakers SB 102 s/n BES043603 2018 Construction Tools PC AB No. 9800064201h 2018-01 General information This spare parts list applies to the following: Part number 8460030030
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationOverview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)
Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating
More informationDiaphragm Accumulators
Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for storing
More informationDifferential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN
Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................
More informationOverview of types. Technical data. Safety notes
Technical data sheet R2..-S.. Open-close ball valves, 2-way, with internal thread For open and closed cold and warm water systems For shut-off functions on the water side and 2-point controls in U and
More informationPressure Relief Valve DHV 718
Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media
More informationRegulators repair and maintenance. 1st stage MC5. MC5 INT HZ MC5 DIN 300 bar HZ
1st stage MC5 MC5 INT HZ 800098 MC5 DIN 300 bar HZ 800099 January 2008 Rev. MC5 / 1 Ed. A / 08 1 1st stage MC5 WARNING! This document is intended for experienced technical personnel who have already attended
More informationSB 152. Spare parts list. Hydraulic breakers. SB 152 s/n BES Construction Tools PC AB No
SB 152 Spare parts list Hydraulic breakers SB 152 s/n BES043707 2018 Construction Tools PC AB No. 9800041001 2018-01 General information This spare parts list applies to the following: Part number 8460030040
More informationConnection solutions for the gas industry Date: 04/2013
Catalogue 20 WEH Connectors Pressure-tight connections in seconds for gaseous applications Connection solutions for the gas industry Date: 04/2013 WEH - We Engineer Hightech All rights reserved, WEH GmbH
More informationHydraulic Piston Accumulators
Ride Control Engineering Services PWCE Extendavator Paul Wever Construction Equipment Co., Inc. P.O. Box 85 401 Martin Drive Goodfield, IL 61742-0085 Phone (309) 965-2005 Fax (309) 965-2905 1-800-990-PWCE
More informationOPERATING INSTRUCTIONS
0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0
More informationAnderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent
More informationOperation Manual Piston Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:
More informationPneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0
Operating Manual LTIA3E Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More informationSB 452. Spare parts list. Hydraulic breakers. SB 452 s/n BES Construction Tools PC AB No h
SB 452 Spare parts list Hydraulic breakers SB 452 s/n BES043603 2018 Construction Tools PC AB No. 9800088701h 2018-01 General information This spare parts list applies to the following: Part number 8460030070
More informationSB 52. Spare parts list. Hydraulic breakers. SB 52 s/n BES Construction Tools PC AB No j
SB 52 Spare parts list Hydraulic breakers SB 52 s/n BES043707 2018 Construction Tools PC AB No. 9800069301j 2018-01 General information This spare parts list applies to the following: Part number 8460030010
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationGas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
More informationModel GP PRESSURE REDUCING VALVE Installation & Operation Manual
Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully
More informationPneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0
Operating Manual LTIA5E Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical data
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationTURBO SET 1000 E D $'9 5(9
TURBO SET 1000 Instructions for use and maintenance HOW TO GAS WELD WITH TURBO SET 1000 With gas welding always work methodically : before starting a weld ensure that the parent metal in the weld area
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationAVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions
1234150/3 IM-P123-17 ST Issue 3 AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4.
More information2-port seat valves PN25 with externally threaded connections
4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationService and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13
MC9 1 st Stage 137 1 st STAGE MC9 Jannuary 2009 - Rev. MC9 /B Ed. C/13 138 WARNING! This manual is intended for use by expert technicians who should attend or have already received training in equipment
More informationUBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions
1270750/7 IM-P127-02 ST Issue 7 UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions 1 General safety information 2 General
More information1. Preface Important Safety Notes Brief Product Information Product Working Principle Installation Guidelines...
Table of Contents 1. Preface...1 2. Important Safety Notes...1 3. Brief Product Information...3 4. Product Working Principle...5 5. Installation Guidelines...6 6. Startup and Commissioning...8 7. Maintenance
More informationPressure Reducing Valve DMV 750
ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction
More informationTHE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301
THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...
More informationBLADDER CARE INSTRUCTIONS
BLADDER CARE INSTRUCTIONS BLADDER REPLACEMENT ACCUMULATOR PRECHARGING ACCUMULATOR PRECHARGE MAINTENANCE ACCUMULATOR COMMISSIONING (For 3000, 4000, 5000, 6000 and 6500-psi Accumulators) (Does not apply
More informationOperating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland
Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU FAS Straight-Way Valve with Packing Gland Please read these operating instructions carefully to ensure a safe operation
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationInstruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual
Instruction Manual Alfa Laval SB Pressure Exhaust Valve ESE02965-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
More informationMounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2
Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting
More informationDeclaration of Conformity as per Directive 97/23/EC
Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Continuous, inline sampling valves Series 27f, with packing Operate with either; Star lever, or
More informationPressure relief valve DHV 725 set range: 0,2-10,0 bar
Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level
More informationPressure Reducing Valve DMV 755 set range: 1,0-9,0 bar
Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long
More informationPilot Operated Pressure Reducing Valve
OPTIONS: USE: Pilot Operated Pressure Reducing Valve Steam & Compressed Air PRV 37 (DN15-DN50) DESCRIPTION The ADCA PRV37 pilot operated pressure reducing valves are designed for use on steam, compressed
More informationSafety valves. Component-tested safety valves DN Compressed Air Accessories II Hoses, valves etc. 15. Technical data. Exhaust capacity air
Component-tested s DN 6 Safety valves serve to blow out non-poisonous and non flammable gases into the atmosphere in order to protect pressure tanks against overpressure. Please note: Only s that have
More informationOXYWAY. Service and Repair Instructions
OXYWAY Single-stage pressure reducer, fixed: Fix I; Fix I side outlet; Fix II; Fix III; Fix III left Single-stage pressure reducer, variable: Fine I; Fine II; Fine III Single-stage pressure reducer, indexed:
More informationSafety relief valves SFV 20-25
MAKING MODERN LIVING POSSIBLE Technical brochure Safety relief valves SFV 20-25 www.danfoss.com/ir Contents Page Introduction........................................................................................3
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification
More informationSTAUFF Accumulators Accessories
Local Solutions For Individual Customers Worldwide STUFF ccumulators Clamps & Supports 28 Safety Blocks 30 Burst Discs 34 Fuse Discs 35 Replacement Back-up Bottles 36 Clamps & Supports ccumulator Clamps
More informationBCV31 DN40 - Blowdown Control Valve
4034850/5 IM-P403-71 AB Issue 5 BCV31 DN40 - Blowdown Control Valve Installation and Maintenance Instructions 1. Safety information 2. Application 3. Technical data 4. Operation 5. Installation 6. Flow
More informationTHE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691
THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationTECHNICAL DATA OBSOLETE
April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,
More informationOperating Instructions Models 36200, , 46200, Hydrostatic Test Pumps
Operating Instructions Models 36200, 362000, 46200, 462000 Hydrostatic Test Pumps 46200 DIMENSIONS: 28 (70cm) L x 24 (60cm) W x 38 (87.5cm) H WEIGHT: PUMP: ENGINE: CONTROL: GAUGE: DISCHARGE HOSE: INTAKE
More informationGAS PRESSURE CONTROL UNIT TYPE 132
GAS PRESSURE CONTROL UNIT TYPE 132 OUR DIVERSITY IS YOUR PROFIT. Gas Pressure Regulator Type 132 Scope of Application Scope of type 132 gas pressure regulator is to maintain the output pressure at a constant
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationSBU 220. Spare parts list. Hydraulic breakers. SBU 220 s/n BES Construction Tools PC AB No
SBU 220 Spare parts list Hydraulic breakers SBU 220 s/n BES090753 2018 Construction Tools PC AB No. 9800097101 2018-01 General information This spare parts list applies to the following: Part number Description
More informationHorne Engineering Ltd
Horne Engineering Ltd Po Box 7, Rankine Street Johnstone, Renfrewshire Scotland, PA5 8BD Tel: 01505 321455 Fax: 01505 336287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE T105A/106A/107A/108A
More informationType /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation
3/2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without notice.
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationCRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES
CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES Sampling Valves Installation Commissioning and Operating Instructions SD IL 300 & SD IL 400 Inline Sampling Valve This
More informationSummary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.
Page 1 of 15 Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below. Model Number A25-XXXX-3.6K Series A40-XXXX-3K Series A40X-XXXX-3.6K Series A60-XXXX-3K
More information