2-Port and 3-Port Seat Valves with Female Thread, PN16

Size: px
Start display at page:

Download "2-Port and 3-Port Seat Valves with Female Thread, PN16"

Transcription

1 4 362 VVI4 VXI4 2-Port and 3-Port Seat Valves with Female Thread, PN6 VVI4... VXI4... ronze valve body CC49K (Rg5) DN5... DN50 k vs m 3 /h Female threaded connections Rp as to ISO 7/ Can be equipped with actuators SQX... and SKD... Use For use in heating, in ventilating and air conditioning systems as a control or safety shutoff valve as per DIN For closed and hydraulic circuits. Media Standard version for: Cooling water Chilled water Low temperature hot water High temperature hot water Water with anti-freeze Saturated steam (up to max..5 bar abs.) rine C Media below 0 C: SZ6.5 stem heating element required to prevent freezing of the valve stem in the sealing gland. Water with anti-freeze and brine: down to 25 C as per DIN 358 (stress case I) CEN4362en For sia Pacific Use Only! Siemens uilding Technologies HVC Products

2 Type summary Type Type DN k vs S v 2-port valves 3-port valves [m 3 /h] VVI VXI > 50 VVI4.5-4 VXI VVI VXI > 00 VVI VXI VVI VXI VVI VXI VVI VXI DN = Nominal size k vs = Nominal flow rate of cold water (5 30 C) through the fully open valve (H 00 ), by a differential pressure of 00 kpa ( bar) S v = Rangeability k vs / k vr as per VDI 273 k vr = The lowest value for k v at which the characteristic tolerance is still maintained, at a differential pressure of 00kPa ( bar) ccessories Ordering Electric stem heating element, C 24 V, required for media below 0 C : SZ6.5 When ordering, please specify the quantity, product name and type code. The type SQX and SKD actuators must be ordered separately. Example 6 3-port valves, type VVI Delivery Valve and actuator are packed and supplied separately. Equipment combinations Valves SQX... SKD... 2) p s p s 2) VVI VXI VVI4.5-4 VXI4.5-4 VVI VXI VVI VXI VVI VXI VVI VXI VVI VXI Data sheet , 4563 For 3-port valves in diverting function, max. 00kPa is recommended. If noise is permitted, the same values apply as for mixing applications 2) Valid for 2-port valves only = Maximum permissible differential pressure across the valve's control path, valid for the entire actuating range of the motorized valve (maximum recommended operating differential pressure) p s = Maximum permissible differential pressure at which the motorized valve will close securely against the pressure (close off pressure) 2/8 uilding Technologies 2-Port and 3-Port Seat Valves with Female Thread, PN6 CEN4362en HVC Products For sia Pacific Use Only!

3 Overview of actuators ctuator Type of actuator Operating voltage Positioning signal Spring return function Positioning time Positioning force SQX32.00 Motoric C 230 V 3-position No 50 s 700 N SQX s SQX82.00 C 24 V 50 s SQX s SQX62 DC 0 0 V 35 s SKD32.50 Electro- C 230 V 3-position No 20 s 000 N SKD32.2 hydraulic Yes 30 s SKD32.5 Yes 20 s SKD82.50 C 24 V No 20 s SKD82.5 Yes 20 s SKD60 DC 0 0 V No 30 s SKD62 yes 30 s and / or DC m or Ω Pneumatic actuators Pneumatic actuators are available on request from your local office. For VXI4 the application is only possible if the valve is used as mixing valve Sizing Flow diagram V 00 [m³/h] DN - k vs p v00 [bar] p v V 00 [l/s] 4362D0 p v 00 = Differential pressure across the fully open valve and the valve s control path by a volume flow V & 00 &V 00 = Volume flow through the fully open valve (H 00 ) 00 kpa = bar 0 mwg m 3 /h = 78 l/s water at 20 C uilding Technologies 2-Port and 3-Port Seat Valves with Female Thread, PN6 CEN4362en HVC Products For sia Pacific Use Only! /8

4 Valve flow characteristics VVI4... VXI Flow k v / k vs D02 Flow k v / k vs D03 Stroke H / H 00 Stroke H / H 00 Working pressure and temperature Working pressure [bar] D04 Working temperature [ C] Working pressure staged as per ISO 7268 and EN 333 at operating temperatures of C as per DIN 4747 and DIN 358. Mechanical design VVI4 mixing VXI4 diverting 4362Z Z08 = 00 % = 0 00 % = 00 0 % 4362Z09 The two-port seat valve does not become a three-port valve by removing the blank fitting. 4/8 uilding Technologies 2-Port and 3-Port Seat Valves with Female Thread, PN6 CEN4362en HVC Products For sia Pacific Use Only!

5 Notes Engineering We recommend installation in the return pipe, as the temperatures in this pipe are lower for applications in heating systems, which in turn, extends the stem sealing gland's life. Water quality requirements as per VDI We generally recommend to install a strainer to increase the valve's functional safety. For media below 0 C, use the electric SZ6.5 stem heating element to prevent the valve stem from freezing in the sealing gland. For safety reasons, the stem heating element has been designed for C 24 V / 30 W operating voltage. Use the 3-port valve VXI4 primarily as mixing valve Mounting oth valve and actuator can easily be assembled at the mounting location. Neither special tools nor adjustments are required. The valve is supplied with mounting instructions no Mounting positions Z0 Direction of flow When mounting, pay attention to the valve's flow direction symbol: 2-port 3-port mixing 3-port diverting Commissioning Commission the valve only if the actuator has been mounted correctly. Stem retracts: Increasing flow Through-port opens, bypass closes Stem extends: Decreasing flow Through-port closes, bypass opens Service Stem sealing gland For actuator service work: Turn off the pump and the operating voltage, close the shutoff valves, depressurize the pipes and allow them to cool down. Disconnect the electrical connections, where required, from the terminals. Re-commission the valve only if the actuator has been mounted correctly. The glands can be exchanged without removing the valve, provided the pipes are depressurized and cooled off and the stem surface is unharmed. If the stem is damaged in the gland range, replace the entire stem-plug-unit (on 2-port valves only). Contact your local office or branch. Spare parts Standard version 4363Z03 Replacement for EPDM-O ring sealing gland made from brass, including flat seal made from copper, for cooling water, chilled water, low temperature hot water, high temperature hot water, saturated steam, and brine C For VVI4... and VXI4... DN5... DN50 (Stem dia. 0 mm) /8 uilding Technologies 2-Port and 3-Port Seat Valves with Female Thread, PN6 CEN4362en HVC Products For sia Pacific Use Only!

6 Disposal The valve must be dismantled and separated into its various constituent materials before disposal. Observe all local and applicable laws. Warranty The technical data supplied for these valves is valid only for valves used in conjunction with the actuators listed under «Equipment combinations». Use with third-party actuators invalidates any warranty offered by Siemens uilding Technologies / HVC Products. Technical data Operating data PN class PN6 to EN333 Valve flow characteristic Through-port 0 30 % % ypass (VXI4...) % Leakage Through-port ypass (VXI4 ) Permissible media linear n gl = 3 as per VDI / VDE 273 linear ccording to DIN EN % of k vs value % of k vs value Cooling and chilled water, low-temperature hot water and water with frost protection additives. Recommendation: Water should be treated as specified in VDI 2035 Temperature of medium C Rangeability S v > 50 (DN5), > 00 (DN 20) Permissible operating pressure 600 kpa (6 bar), ISO 7268 / EN 333 Materials Nominal stroke Valve body Plug Stem Sealing gland Gland materials 20 mm ronze CC49K (Rg5) rass Stainless steel rass EPDM O-rings Dimensions / Weight Dimensions See «Dimensions» (table) Female threaded connections Rp... as to ISO 7/ Weight See «Dimensions» (table) S v = Rangeability k vs / k vr as in VDI 273 k vs = Nominal flow rate of chilled water (5 to 30 C) through the fully opened valve (H 00 ) at a differential pressure of 00 kpa (bar). k vr = The lowest value for k v at which the characteristic tolerance is still maintained, at a differential pressure of 00 kpa ( bar) 6/8 uilding Technologies 2-Port and 3-Port Seat Valves with Female Thread, PN6 CEN4362en HVC Products For sia Pacific Use Only!

7 Dimensions L3 Rp H H H2 4362M0 L2 L N DN L L2 L3 H H2 H + SQX H + SKD G N [mm] [mm] [mm] [mm] [mm] [mm] [mm] [inches] [mm] kg [kg] VVI Rp½ 60.3 VVI > 450 > 525 Rp½ 60.3 VVI Rp¾ VVI Rp 64.7 > 460 > 535 VVI Rp/ VVI Rp/ > 470 > 545 VVI Rp L3 Rp H H H2 4362M02 L2 L N DN L L2 L3 H H2 H + SQX H + SKD G N [mm] [mm] [mm] [mm] [mm] [mm] [mm] [inches] [mm] kg [kg] VXI Rp½ 60.5 VXI > 450 > 525 Rp½ 60.5 VXI Rp¾ 60.6 VXI Rp > 460 > 535 VXI Rp/ VXI Rp/ > 470 > 545 VXI Rp uilding Technologies 2-Port and 3-Port Seat Valves with Female Thread, PN6 CEN4362en HVC Products For sia Pacific Use Only! /8

8 8/ Siemens uilding Technologies Ltd uilding Technologies 2-Port and 3-Port Seat Valves with Female Thread, PN6 CEN4362en HVC Products For sia Pacific Use Only!

2-port and 3-port seat valves, PN16

2-port and 3-port seat valves, PN16 s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections

More information

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils 4 440 Three-port valves with flange, PN6 VXF4... Three-port valves with flange, PN6 Can be used as mixing or diverting valves Grey cast iron GG-25 DN5...50 mm k vs.9...300 m 3 /h Stroke 20 or 40 mm Can

More information

Two-port seat valves

Two-port seat valves 4 345 Two-port seat valves with flange, PN16 VVF45... Two-port seat valves with flange, PN16 Spheroidal cast iron GGG-40 DN50...150 mm k vs 19...300 m 3 /h Stroke 20 or 40 mm Can be equipped with actuators

More information

2-port and 3-port valves PN 16

2-port and 3-port valves PN 16 OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

3-port seat valves with externally threaded connection, PN 16

3-port seat valves with externally threaded connection, PN 16 4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

Two-port valves, male threaded, PN25

Two-port valves, male threaded, PN25 4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...

More information

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Technical data sheet. Type overview. Technical data. Safety notes.   T5-R2.. Open-close en v Subject to changes 1 / 3 Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling

More information

Seated valves VRB 3, VRG 3

Seated valves VRB 3, VRG 3 Data sheet Seated valves VRB 3, VRG 3 Description VRB, VRG valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol concentrations

More information

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

BTV. Internally threaded 2-way control valve. Flow characteristics. Function Internally threaded 2-way control valve The valves are designed for control of hot, cold or glycol-mixed water in heating and ventilation systems. They are pressure balanced (from DN20-50, not DN15) and

More information

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Overview of types.   T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2) Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating

More information

Products no longer available

Products no longer available Technical data sheet R2.. Characterized control valves, 2-way, with internal thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

Radiator valves VDN1.. VEN1..

Radiator valves VDN1.. VEN1.. 2 105 EN 215 Straight valves VDN1.. Angle valves VEN1.. ACVATIX TM Radiator valves VDN1.. VEN1.. DIN-norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated DN 10, DN 15 and DN 20

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

Radiator valves VDN2.. VEN2.. VUN2..

Radiator valves VDN2.. VEN2.. VUN2.. 2 106 EN 215 Straight valves VDN2.. Angle valves VEN2.. Reverse angle valves VUN2.. ACVATIX TM Radiator valves VDN2.. VEN2.. VUN2.. NF norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated

More information

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION 01 These seat valves are of globe construction with a linear moving spindle and a modified parabolic characterised plug operating against the upper seat which controls flow quantity to suit the load. The

More information

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ] Technical data sheet C2..QP-.. For closed cold and warm water systems For modulating control of airhandling and heating systems on the water side Snap-assembly of the actuator overview DN [ ] Vnom [ l/h]

More information

3-way control valves VK 3

3-way control valves VK 3 Data sheet 3-way control valves VK 3 Description / Application VK 3 valves are a range of 3 port high specification flanged valves for chilled water, LPHW, MPHW, HPHW (low, medium or high pressure hot

More information

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

Rotary valves HRB 3, HRB 4

Rotary valves HRB 3, HRB 4 Data sheet Rotary valves HRB 3, HRB 4 Description HRB rotary valves can be used in combination with electric actuators AMB 162 and AMB 182. Features: Lowest leakage in class Unique position indicator (visible

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Data sheet Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32) VGx-xx-xx Externally Threaded Control all Valves PN25 (DN15 TO DN32) PPLICTION The VG2 2-Way and VG3 3-Way Control all Valves control hot and chilled water with glycol solutions up to 50% according to

More information

VZL valve - 2/3/4-way

VZL valve - 2/3/4-way VZ valve - 2/3/4-way Description Stem extension plug VZ 2 VZ 3 VZ 4 VZ valves provide a high quality, cost effective solution for the control of hot and/or chilled water for fan coil units, small reheaters,

More information

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32) VGx-xx-xx Externally Threaded Control all Valves PN25 (DN15 TO DN32) PPLICTION The VG2 2-Way and VG3 3-Way Control all Valves control hot and chilled water with glycol solutions up to 50% according to

More information

Type overview. R B2 en-gb subject to changes 1

Type overview.   R B2 en-gb subject to changes 1 Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of

More information

V311. Venta. Three-way Plug Valve, Flanged PN 16

V311. Venta. Three-way Plug Valve, Flanged PN 16 1 Three-way Plug Valve, Flanged PN 16 can be used in a wide range of applications, such as heating, cooling, air handling and domestic hot water systems. Soft EPDM seals provide tight shut off. The valve

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes Technical data sheet R2..-S.. Open-close ball valves, 2-way, with internal thread For open and closed cold and warm water systems For shut-off functions on the water side and 2-point controls in U and

More information

Seated valve for steam (PN 25)

Seated valve for steam (PN 25) Data sheet Seated valve for steam (PN 25) VFS 2 Two way valve, flange Description VFS 2 valve is a range of 2 port flanged valve for chilled water, PHW, MPHW, HPHW (low, medium or high pressure hot water)

More information

AVP-F. p setting range (bar) Code No. 003H6200

AVP-F. p setting range (bar) Code No. 003H6200 Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator

More information

Products no longer available

Products no longer available Technical data sheet R3 / R3G Change-over ball valve, 3-way, with internal thread for closed cold and warm water systems for switching functions on the water side and 2-point controls in air-handling and

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet R2..xx-S.. Characterised control valves, 2-way, with internal thread For open and closed cold and warm water systems For modulating water-side control of U and heating systems ir bubble

More information

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange Data sheet Pressure balanced valves (PN 25) 2-way valve, external thread VB 2 2-way valve, flange Description VB 2 and VB 2 are two-way valves designed to work with Danfoss electric actuators AMV(E) 0,

More information

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

DS MZ, MZF, MJF THREE-PORT SEAT VALVES DS 4.610 11/99, F, THREE-PORT SEAT VALVES Specification No. 626-3-XXX These seat valves are of 'globe' construction with a linear moving spindle and a modified parabolic characterised plug operating against

More information

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Description AVP(-F) is a self-acting differential pressure controller primarily for use in district heating systems.

More information

Rotary valves HRB 3, HRB 4

Rotary valves HRB 3, HRB 4 Data sheet Rotary valves HRB 3, HRB 4 Description HRB rotary valves can be used in combination with electric actuators AMB 162 and AMB 182. Features: Lowest leakage in class Unique position indicator (visible

More information

Pressure balanced valves (PN 25)

Pressure balanced valves (PN 25) Data sheet Pressure balanced valves (PN 25) 2-way valve, external thread VB 2 2-way valve, flange Description VB 2 and VB 2 are two-way valves designed to work with Danfoss electric actuators AMV(E) 10,

More information

6-way characterised control valves DN15 / DN 20 / DN 25

6-way characterised control valves DN15 / DN 20 / DN 25 6-way characterised control valves DN15 / DN 20 / DN 25 Table of contents Introduction 2 Project planning 2 Structure of the 6-way characterised control valves 2 Range of use 2 Characteristic curve 3 Flow

More information

6-way characterised control valves DN15 and DN 20

6-way characterised control valves DN15 and DN 20 6-way characterised control valves DN15 and DN 20 Table of contents Introduction 2 Project planning 2 Structure of the 6-way characterised control valves 2 Range of use 2 Characteristic curve 3 Flow direction

More information

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in

More information

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN Data sheet Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN 40-100 Description AB-PM is ideal for staged installation and commissioning AB-PM is a combined

More information

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Seated valve for steam (PN 25) VFS 2 2-way valve, flange Data sheet Seated valve for steam (PN 25) VFS 2 2-way valve, flange Description VFS 2 valve is a range of 2 port flanged valve for chilled water, PHW, MPHW, HPHW (low, medium or high pressure hot water)

More information

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Siemens Building Technologies HVAC Products VGG... VGF... VGH... 7 636 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN 161 in connection with SKP... actuators Suitable

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

HERZ - Compact Flow Controller with

HERZ - Compact Flow Controller with HERZ - Compact Flow Controller with Integrated Control Valve Data sheet for flanged compact PIBCV PN 16, Issue 0616 Dimensions in mm min. 200 mm control valve cone valve seat H flow controller cone actuator

More information

HERZ - Compact Flow Controller with

HERZ - Compact Flow Controller with HERZ - Compact Flow Controller with Integrated Control Valve Data sheet for flanged compact PIBCV PN 16, Issue 1016 Dimensions in mm min. 200 mm control valve cone valve seat H flow controller cone actuator

More information

DS MB, MBF THREE PORT VALVES

DS MB, MBF THREE PORT VALVES DS 4.501 04/96, F THREE PORT VALVES Specification No. 617-X-XXX* F 618-X-XXX* and F valves are of the 3-port rotary-shoe type. They are characterised for use as mixing or diverting valves, with hot or

More information

AVPQ/AVPQ-F, PN 16. Application

AVPQ/AVPQ-F, PN 16. Application Data sheet Differential pressure and flow control AVPQ/AVPQ-F, PN 16 Application AVPQ is a self-acting differential pressure and flow control primarily for use in district heating systems. AVPQ closes

More information

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Data sheet Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Description DN 15-40 DN 50 DN 65-100 AHP is a self-acting differential pressure controller primarily for use

More information

Ballorex Dynamic Description. Versions. Benefits. Balancing

Ballorex Dynamic Description. Versions. Benefits. Balancing Ballorex Dynamic Description The Ballorex Dynamic valve is a combined pressure independent flow limiter and control valve which maintains a constant flow independently of pressure changes in heating or

More information

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16 Data sheet Differential pressure control and flow limiter AVPB/AVPB-F, PN 16 Application AVPB is a self-acting differential pressure control and flow limiter primarily for use in district heating systems.

More information

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH... 7 66 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN 161 in connection with SKP... actuators Suitable

More information

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH...

VGG... VGF... VGH... Gas Valves. Building Technologies HVAC Products VGG... VGF... VGH... 7 66 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN161 in connection with actuators Suitable for use

More information

Dimensioning open-close, control and pressure-independent valves. Table of contents. General notes for project planning

Dimensioning open-close, control and pressure-independent valves. Table of contents. General notes for project planning General notes for project planning Dimensioning open-close, control and pressure-independent valves Table of contents Introduction 2 Design and dimensioning General 3 Dimensioning steps Open-close valves

More information

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve Series Self-operated Pressure Regulators Type -6 B Excess Pressure Valve Application Set points from 0.2 to 20 bar with valves G ½, G ¾, and G as well as DN, DN 2, DN 0, and DN 0 Nominal pressure PN 2

More information

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version Series 44 Self-operated Pressure Regulators Type 44-1 B Pressure Reducing Valve Type 44-6 B Excess Pressure Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT

More information

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative

More information

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version Series 44 Self-operated Pressure Regulators Type 44-0 B Pressure Reducing Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT to 1 NPT as well as NPS ½ and 1 Pressure

More information

Valves for Biogases and Recycling Gases

Valves for Biogases and Recycling Gases 7 6 ISO 9001 VRF... with SKP20... actuator VRH... with SKP20... actuator Valves for Biogases and Recycling Gases Actuators VRF10... VRH10... Gas valves designed for gas trains for use with slightly aggressive

More information

Differential Pressure Control Valve. Passim

Differential Pressure Control Valve. Passim Differential Pressure Control Valve Passim 2 Table of contents Chapter Nexus Valve Passim DN 15-50, DN 65-80 1. Safety instructions 4 1.1 Rules/regulations 4 1.2 Intended use 5 1.3 Initial operation 5

More information

PCTV/PCMTV/PCTVS15-25

PCTV/PCMTV/PCTVS15-25 PTV/PMTV/PTVS N 15-25 revision 02 2017 PTV/PMTV/PTVS15-25 Pressure independent control valves, N15-N25 with integrated flow limiter for thermal emitters and differential pressure regulator PTV/PMTV/PTVS

More information

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread Data sheet 2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread Description VGS is pressure relieved 2-way normally open (NO) valves for steam, designed to be combined with: -

More information

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

DIFFERENTIAL PRESSURE REGULATING VALVE zcon DIFFERENTIAL PRESSURE REGULATING VALVE zon Body material pressure diameter Max. temperature Brass DN 15-50 120 according to the pressure equipment directive 2014/68/UE does not require E marking FEATURES

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

Pressure independent control valve (PICV) FLOWMATIC

Pressure independent control valve (PICV) FLOWMATIC Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow

More information

VFPIP/VFPIM/VFPI 15-25

VFPIP/VFPIM/VFPI 15-25 VFPIP/VFPIM/VFPI N 15-25 revision 12 2016 VFPIP/VFPIM/VFPI 15-25 Pressure independent control valves, N15-N25 with integrated flow limiter for thermal emitters and differential pressure regulator VFPIP/VFPIM/VFPI

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

TBV-CM. Combined control & balancing valves for small terminal units For modulating control TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet V5001P Kombi-Auto Differential Pressure Control Valve Product specification sheet Content Application...1 Special Features...1 Valve Efficiency...1 Technical Data...2 Construction...2 Materials...2 Method

More information

PCMTV Pressure independent control valves, DN20-DN32 with integrated flow limiter for thermal emitters and differential pressure regulator

PCMTV Pressure independent control valves, DN20-DN32 with integrated flow limiter for thermal emitters and differential pressure regulator revision 02 2017 PMTV20-32 Pressure independent control valves, N20-N32 with integrated flow limiter for thermal emitters and differential pressure regulator PMTV valves are intended for use in fan-coil

More information

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS Description VZ 2 VZ 3 VZ 4 VZ valves provie a high quality, cost effective solution for the control of hot an/or chille water for fan coil units, small reheaters, an recoolers in temperature control systems.

More information

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread Data sheet 2 - way valve for steam, pressure relieved (PN 25) VGS - external thread Description VGS is pressure relieved 2-way normally open (NO) valves for steam, designed to be combined with: - AVT Temperature

More information

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting Data sheet Differential pressure controller (PN 16) AVPL return mounting, adjustable setting Description It can be used on primary side of house substations for smaller systems such as one and two-family

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions VB-7323 Series 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions Application VB-7323 series three-way diverting valves control hot or chilled water in heating or air conditioning systems.

More information

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH...

VGF... VGH... Building Technologies Division Infrastructure & Cities Sector VGG... VGF... VGH... 7 66 VGG... VGF... VGH... Gas Valves VGG... VGF... VGH... Single valves of class A for installation in gas trains Safety shutoff valves conforming to EN 161 in connection with actuators Suitable for use

More information

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators Self-operated Regulars Flow and Differential Pressure Regular Type 42-37 Flow and Differential Pressure or Flow and Pressure Regular Type 42-39 Type 42-37 Type 42-39 Fig. 1 Flow and differential pressure

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

B2KL: 6-way ball valve with male thread, PN 16

B2KL: 6-way ball valve with male thread, PN 16 Product data sheet 3.1 58.001 K: 6-way ball valve with male thread, PN 16 How energy efficiency is improved fficiency means precise control and low actuating forces eatures 6-way ball valve for changeover

More information

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control TA-Modulator Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control IMI TA / Control valves / TA-Modulator TA-Modulator The

More information

Pressure reduction controller (PN 16, 25, 40)

Pressure reduction controller (PN 16, 25, 40) Pressure reduction controller (PN 16, 25, 40) AFD / VFG 2( - for water AFD / VFGS 2 - for steam Description The controller has a control valve, an actuator with one control diaphragm and a spring for pressure

More information

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control. Document No. CAN7E-P MFB LX Series Modulating Control Valve Description Valves with magnetic actuator for modulating capacity control of refrigeration units and for heat recovery. Features Quick positioning

More information

Pressure and Flow Control Valves DBGM, German and European Patents

Pressure and Flow Control Valves DBGM, German and European Patents Pressure and Flow Control Valves DBGM, German and European Patents Absolutely Reliable Pressure and Flow Control In water mains of sizes DN 50 to DN 150, ERHARD Control Valves in straight or angle pattern

More information

JRGURED Pressure reducing valves

JRGURED Pressure reducing valves JRG JRGURED Pressure reducing valves JRGURED 12 11 6 5 7 3 1 4 2 8 10 9 The JRGURED pressure reducing valves is a compact fitting for water systems consisting of a strainer and a pressure reducing valve.

More information

STA. Double regulating valves DN 15-50

STA. Double regulating valves DN 15-50 STA Double regulating valves DN -0 IMI TA / Balancing valves / STA STA The STA double regulating valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS Description VZ 2 VZ 3 VZ 4 VZ valves provie a high quality, cost effective solution for the control of hot an/or chille water for fan coil units, small reheaters, an recoolers in temperature control systems.

More information

RA-N radiator valves with integrated presetting and self-sealing tailpiece

RA-N radiator valves with integrated presetting and self-sealing tailpiece Data sheet RA-N radiator valves with integrated presetting and self-sealing tailpiece EN 215 Application Straight version Angle version Horizontal angle version All RA-N valve bodies can be used together

More information

Automatic balancing valves ASV

Automatic balancing valves ASV Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

Compressed Air Conditioning Catalog Chapter I

Compressed Air Conditioning Catalog Chapter I Compressed Air Conditioning Catalog Chapter I 2 Compressed Air Conditioning Welcome Welcome New technologies and materials, design innovations and the integration of bus-suitable electronics have opened

More information

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com STAD Series Balancing and control valves Technical Data Sheet WattsIndustries.com Description STAD Series variable-orifice threaded valves are designed for flow control and monitoring in climate control

More information

Double valves for biogases and recycling gases

Double valves for biogases and recycling gases 7 649 Double valves for biogases and recycling gases VRD4... Valve (class A) for installation in gas trains Safety shutoff valves in connection with actuators (conforming to EN 161) Suited for use with

More information

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC 05 Elster GmbH Edition 0.5 Translation from the German 058 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Linear flow control VFC Linear flow control with actuator IFC Contents

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection) Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Type 42-10 RS Check Valve (backflow protection) Mounting and Operating Instructions EB 3009 EN Edition December 2015 Definition

More information

PNEUMATIC CONTROL VALVES PV25 (EN) V25G globe control valves with linear actuators PA series

PNEUMATIC CONTROL VALVES PV25 (EN) V25G globe control valves with linear actuators PA series PNEUMATIC CONTROL VALVES PV25 (EN) V25G globe control valves with linear actuators PA series DESCRIPTION The PV25 control valves are single seated, two-way body constructed with in-line straight connections.

More information