Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Size: px
Start display at page:

Download "Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI"

Transcription

1 Bernhard Thomas September 2018 EnCal 3000 prochain Energy in Gas with ROI

2 Agenda 1 Introduction The new EnCal 3000 prochain Technical details Outlook

3 Introduction 2

4 What we measure and why 3 What we measure Heating Value Density Compressibility Composition Why we measure Volume to energy to $value

5 Current Gas Analyzer Portfolio 4 Gas Analyzer GasLab Q2 - Fast correlative analyzer for natural gas The GasLab Q2 ensures a fast online natural gas analysis with ISO/GPA/ASTM calculations. It has a small footprint and requires no carrier gas. It fulfills accuracy Class A according to OIML R140. Gas Chromatograph EnCal High accuracy energy measurement The EnCal 3000 is specially designed for fiscal energy measurement of natural gas. It uses chromatography components based on the latest Micro Electro Mechanical Systems (MEMS) technology and capillary columns. This yields in highly repeatable and accurate analysis results.

6 Gas Chromatograph EnCal Features Modular setup Agilent column modules Stand-alone operation 5 streams capability Auto calibration / Internal bypass Outside installation possible Serial &TCP Modbus ATEX / IECEx / FM Exd approved Applications Available for a wide variety of applications (Natural/Bio/eGas, H2S, CO2, Odorants, up to 13 components with a Quad)

7 The new EnCal 3000 prochain 6

8 Gas Chromatograph EnCal 3000 prochain 7 Multi-stream custody transfer gas chromatograph Own GC module technology - Dual column, single train - Market leading MEMS GC techniques 5 streams with one analyzer ISO / GPA / ASTM* and AGA* calculations Application: C6+ ATEX / IECEx / ccsaus Exd approved Lowest carrier gas consumption in the world *Not in first release

9 Gas Chromatograph EnCal 3000 prochain 8 Multi-stream custody transfer gas chromatograph Up to two GC modules* Modular electronics, based on Elster encore platform Easy-to-use PC software Local display optional Local USB-port optional *Not in first release

10 Installation everywhere 9 Ambient temperature -25 to +55 C / -13 to 131 F Place of use Installation close to the sampling point up to Ex Zone 1 Inside or Outside

11 Measure everything (up to C6+) 10

12 Calculate everything 11 Calculated values Density - kg/m3 - lb/scf Wobbe index Compressibility Heating Values - MJ/m3 - BTU/scf - kj/kg Supported standards ISO 6976 GPA-2172 ASTM D3588* AGA-5* *Not in first release

13 Options 12 Local display Mounting plate Local USB

14 Comparison EnCal 3000 prochain vs. EnCal EnCal 3000 prochain EnCal 3000 Application range C 6 + C 6 + / C 9 / C 9 HCDP / Bio / egas / H 2 S Accuracy 0,25% (with SLC); 0,1% can be increased with multi level calibration (MLC). Repeatability 0,025%RSD 0,005%RSD Cycle time C 6 + max. 4 min 3 min Ex approval (Exd) ATEX / IECEx / ccsaus ATEX / IECEx / FM Metrology NIM (China)*, OIML R140 class A* National approvals for Germany, France, etc. Helium usage 7 years one bottle (50 liter) 2 years one bottle (50 liter) Configuration software ensuite RGC3000 (Agilent) *Not in first release

15 Technical details 14

16 GCM new development, own technology 15 Main application: C6+ analysis - Accuracy: 0,25% (with SLC); can be increased with multi level calibration (MLC). - Repeatability: 0,025%RSD - Limit of detection C5: 50ppm Very low helium consumption (half of EnCal 3000) Single train, dual column Easy configuration, simple troubleshooting Channel replacement with two screws Cycle time C6+: Analysis time 2-2,5 min + cooling phase up to 1,5 min cycle (depending on ambient temperature)

17 Complete GC module on single PCB 16 GCM1000 concept: - 1 injector, fixed loop - 2 detectors - Pre column + main column - Backflush to detector

18 GCM1000 concept 17

19 Separation column 18 Channel length of cm Channel diameter of 0,2 0,4 mm Manufactured using MEMS technology: located on a silicon/pyrex chip in a meandering configuration.

20 Sample injector 19 The injection must guarantee the precise delivery of the sample in terms of volume, pressure, temperature and flow rate. Manufactured using MEMS technology: Channels etched in silicon and diaphragm valves. Achieves high-precision control of the injection volume and temperature.

21 Thermal Conductivity Detector (TCD) 20 Wheatstone bridge Manufactured using MEMS technology: Circuit of 4 freely suspended platinum filaments on a Silicon/Pyrex chip.

22 Gas supply connections 21 Connection Position on the device/note Sample gas streams 1 5 Calibration gas cylinder with P1-1K Carrier gas cylinder with helium Sample and blocking vent (SBV) Module vent (MV) It is possible to measure up to 5 different gases in sequence. Used to maintain measurement accuracy. For transporting the measurement gas inside the device; waste gas is released into the housing. The unmeasured sample gas is released at ambient pressure. The waste sample and carrier gas is released at ambient pressure. Purge vent (PV) Flushing or bypass gas is released at a high flow rate.

23 Inputs/Outputs & Communication Interfaces 22 Digital outputs: 2 (24V DC, common earth, electrically isolated) Digital inputs: 2 (maximum supply voltage 9V, electrically isolated) Communication interfaces 1 x Ethernet (TCP/IP; Modbus; ftp; http) 2 x RS485 (Modbus serial/optional display near the device)

24 Local Display (optional) 23 LCD graphic display 128 x 64 dots Operates independently from ensuite Powered by the device Connected to optional IS display board Display values - Serial number, IP address - Errors/Warnings, operating mode - Current operating step, Current calculation standard with the selected settings - Higher heating value, Density at base conditions, Superior Wobbe index, Compressibility factor, Methane number, Carbon dioxide - Gas analysis with 10 components and the total of the C6+ components

25 encore platform 24 Based on proven encore platform (used for FC, USM, GC) Enhanced interface possibilities: - Freely definable Modbus communication (slave/client and master/server) Embedded archives - Events - Hourly/daily / monthly averages Built-in web server for remote front panel Parameterization & Analysis software ensuite (used for all Elster Gas metering devices) EnCal 3000 prochain

26 System overview 25

27 Outlook 26

28 Next steps Usage of the second module for: - egas (power-to-gas technology): H 2 - Biogas: H2, O 2

29 28

EnCal 3000 Gas Chromatograph Hardware Manual KC

EnCal 3000 Gas Chromatograph Hardware Manual KC EnCal 3000 Gas Chromatograph Hardware Manual 73022344 KC 27.01.2016 EnCal 3000 Hardware Manual 27/01/2016 Contact Information... 3 Safety Information... 4 Gas quality measurement system EnCal 3000... 5

More information

EnCal 3000 Gas Chromatograph Hardware Manual g

EnCal 3000 Gas Chromatograph Hardware Manual g EnCal 3000 Gas Chromatograph Hardware Manual 73022344 g 01.06.2015 EnCal 3000 Hardware Manual 01/06/2015 Contact Information... 3 Safety Information... 4 Gas quality measurement system EnCal 3000... 5

More information

EnCal 3000 Quad Gas Chromatograph Hardware Manual g

EnCal 3000 Quad Gas Chromatograph Hardware Manual g EnCal 3000 Quad Gas Chromatograph Hardware Manual 73022350 g 22.06.2017 EnCal 3000 Quad Hardware Manual 22/06/2017 Contact Information... 3 Safety Information... 4 Gas quality measurement system EnCal

More information

EnCal 3000 Gas Chromatograph Hardware Manual LC

EnCal 3000 Gas Chromatograph Hardware Manual LC EnCal 3000 Gas Chromatograph Hardware Manual 73022344 LC 05.10.2016 EnCal 3000 Hardware Manual 05/10/2016 Contact Information... 3 Safety Information... 4 Gas quality measurement system EnCal 3000... 6

More information

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor Anwar Sutan, Metco Services Ltd. Charles Johnson, Metco Services Ltd. Jason Laidlaw,

More information

EnCal 3000 Gas Chromatograph Commissioning and Maintenance Manual Biogas and THT-Devices

EnCal 3000 Gas Chromatograph Commissioning and Maintenance Manual Biogas and THT-Devices EnCal 3000 Gas Chromatograph Commissioning and Maintenance Manual Biogas and THT-Devices 1/38 Document history Version Date Author Changes a 19.10.17 Gas Quality Initial version Only operating instructions

More information

MODEL 131/132 GAS CHROMATOGRAPH

MODEL 131/132 GAS CHROMATOGRAPH MODEL 131/132 GAS CHROMATOGRAPH Envent Engineering Ltd. Model 131/132 Gas Chromatographs are rugged, versatile and reliable online natural gas analyzers. They are robustly designed by engineers and experienced

More information

EnCal 3000 Gas Chromatograph Hardware Manual

EnCal 3000 Gas Chromatograph Hardware Manual EnCal 3000 Gas Chromatograph Hardware Manual Index Index...1 Contact Information...2 Safety Information...3 1 Process Gas Chromatography General Introduction...4 1.1 Gas Chromatography : Analytical Principle...

More information

Technical Bulletin, Communicating with Gas Chromatographs

Technical Bulletin, Communicating with Gas Chromatographs Last Updated: 13- July-2010 TB-080000C Technical Bulletin, Communicating with Gas Chromatographs OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States

More information

ERZ 2000-NG Flow Computer

ERZ 2000-NG Flow Computer ERZ 2000-NG Flow Computer With decades of natural gas measurement experience, RMG has developed the ERZ 2000-NG an approved and best-in-class gas flow measurement solution for all areas of gas volume conversion.

More information

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total

More information

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6 LT GasAnalyzer LT GasAnalyzer Page 1 of 6 LT GasAnalyzer Disturbances in the protective gas supply can cause production losses or affect product quality. In the worst case, it even can endanger life and

More information

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere! The portable Gas Chromatograph is now more versatile than ever. DPS Instruments is pleased to present the newest Portable Companion 2 Gas Chromatograph with room for 2 Detectors. The Companion 2 GC was

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric

More information

Online data sheet FLOWSIC30 GAS FLOW METERS

Online data sheet FLOWSIC30 GAS FLOW METERS Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information LTRASONIC GAS FLOW METER FOR CTION Type Part no. On request The exact device specifications and performance data of the product

More information

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013

Advancements in Gas Chromatography Analyzers - Keeping up with New Technology. Chuck Runkle Gas Phase Product Specialist ASTS June 2013 Advancements in Gas Chromatography Analyzers - Keeping up with New Technology Chuck Runkle Gas Phase Product Specialist ASTS June 0 Capillary Flow Technology -- solves difficult application problems easily

More information

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97

More information

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT APPLICATION NOTE Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT The INFICON 3000 Micro GC provides two fast and accurate solutions for the analysis of coal mine gas components.

More information

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more! After years of development and testing, DPS Instruments is pleased to present the newest, most expandable and versatile Gas Chromatography Systems in history. The DPS 600 Series GC systems are the world

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 6974-4 First edition 2000-04-01 Natural gas Determination of composition with defined uncertainty by gas chromatography Part 4: Determination of nitrogen, carbon dioxide and

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions

More information

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12 Product Information Three in One: Gas Meter Tariff Device Volume Corrector Ultrasonic Gas Meter ECOSONIC X12 ECOSONIC X12 Values you can count on The Application Fields The ultrasonic gas meters of the

More information

Instrument Performance Evaluation, comparing ISO and NORSOK I-106 Dr Paul Holland, EffecTech Group & Jon Carlsen, Norsk Analyse North Sea Flow

Instrument Performance Evaluation, comparing ISO and NORSOK I-106 Dr Paul Holland, EffecTech Group & Jon Carlsen, Norsk Analyse North Sea Flow Instrument Performance Evaluation, comparing ISO 10723 and NORSOK I-106 Dr Paul Holland, EffecTech Group & Jon Carlsen, Norsk Analyse North Sea Flow Measurement Workshop 2017 Overview of presentation Importance

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Multiple Gas#5 GC configuration Jan 2016

Multiple Gas#5 GC configuration Jan 2016 History: Unfortunately there is no single column that can separate: Hydrogen Oxygen Nitrogen Methane CO CO2 Ethane Water Propane Butane Pentane Over the years SRI Instruments has devised several solutions

More information

Real-time Wobbe Index Determination of Natural Gas. J.C. Lötters Bronkhorst

Real-time Wobbe Index Determination of Natural Gas. J.C. Lötters Bronkhorst Real-time Wobbe Index Determination of Natural Gas J.C. Lötters Bronkhorst Real-time Wobbe index determination of gas mixtures Joost Lötters Professor Chief Technology Officer Microfluidic handling systems

More information

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air

More information

Electronic Volume Correctors

Electronic Volume Correctors Electronic Volume Correctors Ben Manson Landis+Gyr October 14, 2016 PUBLIC Agenda Customer Types and suitable equipment Volume corrector standards / regulations Basics of volume correction Gauge v Absolute

More information

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL Improved Reliability in Natural Gas Energy Measurement with the Revised ISO 10723 Standard Gerard Nieuwenkamp - VSL Improved reliability in natural gas energy measurement with the revised ISO 10723 standard

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

LT GasAnalyzer beyond standards

LT GasAnalyzer beyond standards beyond standards LT GASANALYZER Highly performant analyzer for measuring the concentration of technical gases based on a thermal conductivity sensor, an infrared sensor or a para-magnetic sensor. Combinations

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Instruction Manual. Biogas Analyzer InCa Bio 04

Instruction Manual. Biogas Analyzer InCa Bio 04 Instruction Manual Biogas Analyzer InCa Bio 04 Instruction Manual InCa Bio 04 contents - IMPORTANT - Refer to the safety intructions before installation begins 2 Manual InCa Bio 04 07-10-10 R2 Table of

More information

System Overview. TCD Detector temperature setpoint Regulator

System Overview. TCD Detector temperature setpoint Regulator System Overview POPULAR CONFIGURATION GCs Your educational TCD GC is configured on the compact 310 chassis. It is equipped with a TCD Detector, a temperature programmable Column Oven, a 3 Silica Gel packed

More information

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE. Gases&Technology FEATURE Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. B Y M A T T H E W M O N A G L E Abstract Bulk gases are often delivered to

More information

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor

More information

FUNDAMENTALS OF GAS CHROMATOGRAPHY, GAS QUALITY & TROUBLESHOOTING Larry Ewing Chandler Engineering Company LLC

FUNDAMENTALS OF GAS CHROMATOGRAPHY, GAS QUALITY & TROUBLESHOOTING Larry Ewing Chandler Engineering Company LLC FUNDAMENTALS OF GAS CHROMATOGRAPHY, GAS QUALITY & TROUBLESHOOTING Larry Ewing Chandler Engineering Company LLC 2001 N. Indianwood Avenue, Broken Arrow, OK 74012 INTRODUCTION Measurement of the quality

More information

GAS INJECTION TECHNOLOGY GIT

GAS INJECTION TECHNOLOGY GIT GAS INJECTION TECHNOLOGY GIT Innovative and complete solutions ECONOMICAL modular RELIABLE BAUER KOMPRESSOREN offer Gas Injection Technology as a solution to the problems of plastic part production. The

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications. OMNISTAR / THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide range of applications. OMNISTAR /THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM 40 Series Extractive Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O Extractive low cost, low maintenance devices for continuous

More information

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2

* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2 Portable DGA Dissolved Gas Analyzer MITSUBISHI Portable Dissolved Gas Analyzer (PGA-300) is used to analyze 6 kinds of dissolved gases in transformer oil, thereby improving prompt action

More information

Application Note AN-107

Application Note AN-107 SPEC Sensor TM Characterization & Calibration Considerations Scope This document is provided to describe the considerations needed to characterize, calibrate, verify and validate the measurement performance

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs. Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography

More information

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing) 1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings

More information

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING Blair Chalpin Charles A. Matthews Mechanical Design Engineer Product Support Manager Scanivalve Corp Scanivalve Corp Liberty Lake, WA

More information

Long term stability tests of INO RPC prototypes

Long term stability tests of INO RPC prototypes Long term stability tests of INO RPC prototypes While the problem of sudden aging in the glass RPC prototypes is being investigated, a few RPCs of dimension 40 cm 30 cm were fabricated, using glass procured

More information

Gas Measurement Fundamentals Certification. Curriculum

Gas Measurement Fundamentals Certification. Curriculum Gas Certification Institute, LLC P.O. Box 131525 Houston, Texas 77219-1525 281-598-7200 Phone 281-598-7199 Fax contact@gascertification.com www.gascertification.com Curriculum Copyright 2007-2012 Gas Certification

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

FAS-W. Features. Applications. Automatic condensation hygrometer

FAS-W. Features. Applications. Automatic condensation hygrometer FAS-W HUMIDITY ANALYZER Automatic condensation hygrometer the «FAS-W» Moisture Analyzer automatic condensation hygrometer can measure both the volume fraction of moisture and the dew point temperature

More information

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

Thermal Energy Flowmeter Model KEC. Application Range. Special Features Thermal Energy Flowmeter for gases measuring monitoring analysing KEC O O Direct mass flow rate measurement of gases OMeasuring O accuracy: ± 0.3% of full scale ±1.5% of reading on request: ± 0.3% of full

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi

More information

Porter Analytical & Industrial Products

Porter Analytical & Industrial Products Porter Analytical & Industrial Products Porter Analytical & Industrial Products Engineered to Excel in Critical Applications The Porter Instrument Division of Parker Hannifin Corporation is a leading manufacturer

More information

Rapid and Reliable Detection of Dissolved Gases in Water

Rapid and Reliable Detection of Dissolved Gases in Water Rapid and Reliable Detection of Dissolved Gases in Water Andrea Caruso and Massimo Santoro Thermo Fisher Scientific, Milan, Italy Application Note 005 Key Words Chromeleon CDS, Environmental, Fracking,

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...

More information

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com ...makes sense! Combined CO 2 /O 2 analyzers Monitor your process in real-time: BlueSens.com OUR CER RQ ...makes sense! The BlueInOne sensor BlueSens is providing modern and inexpensive measuring solutions

More information

Mass Flowmeters. Mass Flowmeters for Gases

Mass Flowmeters. Mass Flowmeters for Gases Mass Flowmeters Mass Flowmeters for Gases Fast, Accurate, Low Pressure Drop for critical measurement applications! Flow (Std l/min) Response to a step change in flowrate 300 200 100 4 Milliseconds 63%

More information

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas ABB MEASUREMENT & ANALYTICS Continuous gas analyzers EL3060 The specialists for hazardous areas The specialists for hazardous areas ABB Analytics possesses decades of experience in the area of explosion

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic

More information

The instrument will process the samples one by one till all the samples have been cleaned up.

The instrument will process the samples one by one till all the samples have been cleaned up. Table of Contents SPE-01 Cleanup Station... 1 LC-04SP Valve System... 5 LC-04SP Standalone Valve... 10 LC-05 Auto Injector... 12 LC-06 Dosing Pump... 16 LC-08 Column Selector... 17 SPE-01 Cleanup Station

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

Quadruple mass spectrometers (transducer type)

Quadruple mass spectrometers (transducer type) Quadruple mass spectrometers that meet the need for sensitive analysis and low outgassing which were specifically designed to be controlled by PCs Quadruple mass spectrometers (transducer type) M-070QA-TDF,

More information

NGN Series nitrogen generator

NGN Series nitrogen generator NGN Series 8-64 nitrogen generator Applications how it works RK series 5-40 F Blanketing of Chemicals and Pharmaceuticals Gas Assisted Injection Moulding (GAIM) Laser Cutting Food Heat Treament of Ferrous

More information

Addressing the World Shortage of Helium

Addressing the World Shortage of Helium Addressing the World Shortage of Helium Introducing the Programmable Helium Conservation Module GPD Solutions June 2013 Market Situation Unreliable supply of helium worldwide and increasing prices have

More information

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :

More information

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES 1. Applicability and Principle 1.1 Applicability. This method applies to the analysis of carbon dioxide

More information

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no

More information

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation

Gas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation Gas Clean Filters Delivering Clean Gases for GC and GC/MS Operation Gas Clean Filters Fast, leak-free replacement without tools! Each Gas Clean Filter features a unique quick disconnect design which allows

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Dräger X-dock Frequently Asked Questions

Dräger X-dock Frequently Asked Questions COSTS Why do I save costs when using Dräger X-dock? SOFTWARE What are the benefits of using a central database? What is the difference between the X-dock Manager Standard and the Professional Version?

More information

A New GC/MS System Designed for Helium Carrier Gas Conservation

A New GC/MS System Designed for Helium Carrier Gas Conservation A New GC/MS System Designed for Helium Carrier Gas Conservation Approaches for the Smarter Use of Helium Dale R. Walker GCMS Applications Specialist August, 7, 2013 1 Helium Facts How it's produced Where

More information

Flow metering in gases Introduction to COMBIMASS family

Flow metering in gases Introduction to COMBIMASS family Flow metering in gases Introduction to COMBIMASS family - physical principle, basic information - different types of instruments, pricing & delivery time Sales Training Germany October 17 th to 19 th,

More information

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation Page 1 of 19 : SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor Description and Principle of Operation The photoacoustic multi-gas monitor (INNOVA 1412, Innova AirTech Instruments, Denmark) is a highly

More information

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters

More information

PRODUCT OVERVIEW. Gas mixers Test bench systems Leak test and impermeability testing systems High pressure dosing pumps

PRODUCT OVERVIEW. Gas mixers Test bench systems Leak test and impermeability testing systems High pressure dosing pumps PRODUCT OVERVIEW Gas mixers Test bench systems Leak test and impermeability testing systems High pressure dosing pumps COMPLETE SOLUTIONS FLUSYS is solely dedicated to producing solutions for projects

More information

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

MCQ Gas Blender 100 Series 3 Channels Gas Mixer Channels Gas Mixer Revision 1.8 October 2016 High Performance Digital Gas flow Gas Dilutor Blender & Gas for Mixing flow Mixing Gases System and Calibration Routines Technical Data Sheet Lab in a box From

More information

Process Micro-chromatograph PGC 490 ATEX explosion-proof rapid gas analyzer General user manual

Process Micro-chromatograph PGC 490 ATEX explosion-proof rapid gas analyzer General user manual Process Micro-chromatograph PGC 490 ATEX explosion-proof rapid gas analyzer General user manual p. 1 / 26 Table of contents 1. INTRODUCTION 4 2. SAFETY INSTRUCTIONS 4 2.1 Important general information

More information

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range

DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range DigitalFlow GF868 Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range Applications The DigitalFlow GF868 flowmeter is a complete ultrasonic flow metering system for: Flare gas

More information

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values Operations Manual Please read, understand, and follow these instructions before operating this equipment.

More information

Electronic gas volume corrector model DGVC-04

Electronic gas volume corrector model DGVC-04 Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector

More information

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Your local gas generation partner. Precision series Modular gas generation solution for GC. Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,

More information

Series Environmental Chambers

Series Environmental Chambers 3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable

More information

GCMSD-Headspace Analysis SOP

GCMSD-Headspace Analysis SOP Before you start GCMSD-Headspace Analysis SOP Method and Sequences names are restricted to 50 characters (MSD program will crash otherwise) The GC oven and Injection Ports need to be cooled to 50 oc to

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

GAS CHROMATOGRAPHY MAINTENANCE USING UNCERTAINTY BASED CBM

GAS CHROMATOGRAPHY MAINTENANCE USING UNCERTAINTY BASED CBM GAS CHROMATOGRAPHY MAINTENANCE USING UNCERTAINTY BASED CBM Anwar Sutan, i-vigilant Technologies Paul Daniel, i-vigilant Technologies 1 INTRODUCTION On-line gas chromatography is frequently used within

More information

Real-time gas analysis and software for the management of bioprocessing

Real-time gas analysis and software for the management of bioprocessing Understanding bioprocesses from the lab to the production understanding bioprocesses Real-time gas analysis and software for the management of bioprocessing Understanding bioprocesses for more than 15

More information

CHM Gas Chromatography: Our Instrument Charles Taylor (r10)

CHM Gas Chromatography: Our Instrument Charles Taylor (r10) 1/8 Introduction You should already be familiar with the basic concepts of gas chromatography. The purpose of this note pack is to familiarize you with the specific instrument that we will use in our labs.

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Envent Engineering Ltd. Gas Chromatographs Model 131 & 132

Envent Engineering Ltd. Gas Chromatographs Model 131 & 132 Envent Engineering Ltd. Gas Chromatographs Model 131 & 132 User's Manual Revision 6.1 Nov 2018 Table of Content INTRODUCTION... 1 Contacting Envent Engineering Ltd... 1 Canada Office: (Main)... 1 USA

More information

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead!

The. «Modular Alliance» Gas Generators. ALLIANCE, the partnership that keeps the gas flowing. One step ahead! The «Modular Alliance» Gas Generators One step ahead! ALLIANCE, the partnership that keeps the gas flowing. F-DGSi EXPERTISE IS DEFINED BY ALWAYS BEING ONE STEP AHEAD! WE HAVE DESIGNED NEW MODULAR SOLUTION

More information