Albany Connecticut Vermont Westchester

Size: px
Start display at page:

Download "Albany Connecticut Vermont Westchester"

Transcription

1 Natural Gas Sampling Sample Cylinders Grab Sample Panels Natural Gas field sampling is performed to determine gas composition, specific gravity, hydrocarbon dew point and natural gas value. Accurate gas samples are crucial to determining these criteria. Inadequate and poorly maintained equipment can negatively impact and call into question the validity and accuracy of the natural gas being sampled. Engineered to Perform Under Pressure

2 Sample Cylinder Assemblies Sample Cylinders Smooth internal neck transition allows easy cleaning and minimizes trapped gas particles Full-penetration gas tungsten arc-weld construction provides leak-tight sample containment Working pressures up to 5,000 psig 304L and 316L stainless steel materials resist intergranular corrosion Monel, SilcoNert 2000 coating Standard A cylinder assembly for general use or for use with Grab Sample Modules (GSM) without a purge option. Swagelok Albany Connecticut Vermont Westchester offers fully assembled, leak-tight tested grab sample cylinder (GSC) assemblies. Standard offerings come complete with easy-to-use cylinder valves, safety rupture discs, lanyard connected plugs and caps. Available options include quick connects, carrying handles, end caps, cylinder identification and shipping cases. Representative, brittany.schraeder@ swagelok.com or

3 Sample Cylinder Assemblies GSC Pressure-Temperature Ratings Quick Connect Series QC4 QC6 QTM2 Cylinder Material 304L/316L Alloy L/316L Alloy L/316L Alloy 400 Temperature, F ( C) Working Pressure, psig (bar) 0 ( 17) to 10 (-12) 1800 (124) 1800 (124) 10 ( 12) to 100 (37) 1800 (124) 1800 (124) 1500 (103) 1500 (103) 120 (48) 1360 (93.7) 1580 (108) 1350 (93.0) 1350 (93.0) 150 (65) 1360 (93.7) 1580 (108) 200 (93) 1150 (79.2) 1150 (79.2) GSC Dimensions Dimensions, in inches (millimeters), are for reference only and are subject to change. Dimensions, in. (mm) Cylinder Volume, cm3 A B C (133) 2.00 (50.8) 2.36 (59.9) (227) 2.00 (50.8) 2.36 (59.9) (290) 2.00 (50.8) 2.36 (59.9) (350) 2.00 (50.8) 2.36 (59.9) (276) 3.50 (88.9) 3.10 (78.7) Dimensions, in. (mm) Quick Connect Without Purge With Purge D E D E QTM (117) 3.52 (89.4) 6.33 (161) 5.22 (133) QC (101) 4.05 (103) 5.69 (144) 5.75 (146) QC (95.8) 3.89 (98.8) 5.47 (139) 5.59 (142) Representative, brittany.schraeder@swagelok.com or

4 Sample Cylinder Assemblies Ordering Instructions Build a GSC assembly ordering number by combining the designators in the sequence shown below. GSC A 0300 N X XX X - EP Cylinder Material 1 = 304L SS 2 = 304L SS SilcoNert = 316 SS 4 = 316 SS SilcoNert = Alloy 400 Valve Material A = 316 SS B = 316 SS SilcoNert 2000 C = Alloy 400 Cylinder Size 0150 = 150 cm = 300 cm = 400 cm 3 * 0500 = 500 cm = 1000 cm 3 * * Available only in 304L SS Valve Type 1 = D series Rupture Disc A = 1900 psig (130 bar) B = 2800 psig (192 bar) X = None Outage Tube XX = None 10 = 10% 20 = 20% 30 = 30% 40 = 40% 50 = 50% Cylinder Handle H = Handle * X = No handle * Available only on cylinders 400 cm3 and larger Purge N = No purge P = Purge Quick-Connect Type 2 = QTM2 4 = QC4 6 = QC6 * * Pressure rating limited to 1500 psig (103 bar). Options EP = Electropolished cylinder LE = Laser-etched cylinder, followed by specific information PD = TPED cylinder certification SB = Stem and body protectors T = PTFE cylinder coating Omit = No options added Representative, brittany.schraeder@swagelok.com or

5 Grab Sample Panel What is Grab Sampling? Grab sampling, also known as lab sampling, is the collecting of a sample of gas from a pipeline, tank or system with the intent of transporting the sample to a laboratory for analysis. Depending on the process phase, temperature, consistency, chemical makeup and other factors, there are a variety of approaches that can be used to extract a sample. Designed and built with the reliable components you trust from Swagelok Versatile mounting options for easier installation Additional instrumentation is available including gauges, meters and flow indicators Local, certified factory experts Leak-tight, Swagelok tested For Additional Information Regarding Grab Sample Stations Contact Swagelok Albany Connecticut Vermont Westchester Representative, brittany.schraeder@swagelok.com or

6 High quality Swagelok components Experienced engineers to assist with design, component selection, and on-site technical assistance Assembled by factory-certified technicians Fully-pressure tested before delivery Maintain CMTR documentation for each assembly One part number and one purchase order Same Swagelok Limited Lifetime warranty as standard Swagelok products Solidworks 2016, 2D & 3D CAD drawings Testing Each DOT cylinder is hydrostatically tested to at least 5/3 the working pressure. All testing of DOT cylinders is witnessed by a DOT-approved independent inspection agency. Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, trouble-free performance. Function, material compatibility, adequate ratings, proper installation, operation, and maintenance are the responsibilities of the system designer and user. Swagelok products are backed by The Swagelok Limited Lifetime Warranty. For a copy visit, Swagelok Albany info@albany.swagelok.com Swagelok Connecticut info@connecticut.swagelok.com Swagelok Vermont info@vermont.swagelok.com Swagelok Westchester info@westchester.swagelok.com 2017 Swagelok Company dzf

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

Sample C ylinde rs, Acce ssorie s, and O utage Tube s www.swagelok.com Sample C ylinde rs, cce ssorie s, and O utage s Features Sizes from 10 to 3785 cm 3 (1 gal) Working pressures up to 5000 psig (344 bar) 304L and 316L stainless steel and alloy 400 2 Sample

More information

Grab Sampling Systems

Grab Sampling Systems Grab Sampling Systems Application Guide Provides a simple, effective way to safely collect samples Keeps samples in their representative state for analysis an be adapted to meet system requirements Application

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

Sample Cylinders and Accessories

Sample Cylinders and Accessories Sample Cylinders and Accessories SC and MC Series FITOK Group FITOK GmbH (Headquarter) Sprendlinger Landstr. 115, 6069 Offenbach am Main, Germany Tel.: +49 69 8900 4498 Fax: +49 69 8900 4495 FITOK, Inc.

More information

Products Compliant with the Transportable Pressure Equipment Directive (TPED)

Products Compliant with the Transportable Pressure Equipment Directive (TPED) Swagelok Products Compliant with the Transportable Pressure Equipment Directive () 1 www.swagelok.com Swagelok Products Compliant with the Transportable Pressure Equipment Directive () Products Double-ended

More information

Gas delivery systems. How to ensure uninterrupted high quality gas delivery from the source to the apparatus? Dr. Gastons Vereskuns Trakai,Lithuania

Gas delivery systems. How to ensure uninterrupted high quality gas delivery from the source to the apparatus? Dr. Gastons Vereskuns Trakai,Lithuania Gas delivery systems. How to ensure uninterrupted high quality gas delivery from the source to the apparatus? Dr. Gastons Vereskuns Trakai,Lithuania May 7, 2014 What it is gas delivery system? It is a

More information

Proportional Relief Valves

Proportional Relief Valves www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves

More information

VCO O-ring Face Se al Fit tings

VCO O-ring Face Se al Fit tings www.swagelok.com O-ring Face Se al Fit tings /8 to sizes 36 or 36L stainless steel, NPT, S thread, and weld connections 2 O-ring Face Seal Fittings ontents Features........................................

More information

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance CVI Valve Line Exceeds the industry s highest standards for reliability and performance Available in the most standard models with the shortest lead times in the industry Exceptional quality every CVI

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CONSTANT PRESSURE CYLINDER MODEL CP-11 DRAWING NUMBERS AD157CO AD157CP.CE MANUAL NUMBER IOM-184 REVISION Rev. B, 6/7/2018 TABLE OF CONTENTS SAFETY

More information

GasTrak Pro TM Delivery/Control Systems

GasTrak Pro TM Delivery/Control Systems GasTrak Pro TM Delivery/Control Systems Regulator, Purifier and Outlet Sections Introduction GasTrak Pro TM Systems are a unique approach to controlling and delivering high-purity gases distributed in

More information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax: 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

Flange Adapters. Threadless, weldless transition from flanged piping systems to tubing systems

Flange Adapters.   Threadless, weldless transition from flanged piping systems to tubing systems www.swagelok.com Flange dapters Threadless, weldless transition from flanged piping systems to tubing systems Flange types meet SM, IN, N, and IS standards One-piece integrally machined forged body vailable

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER MODEL TCC-5 DRAWING NUMBERS AD417CO AD557CO MANUAL NUMBER IOM-197 REVISION Rev. 0, 12/20/2016 TABLE OF CONTENTS

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

CalCheck. Instrument User Manual V1.8

CalCheck. Instrument User Manual V1.8 CalCheck Instrument User Manual V1.8 Unrivalled Part number: 21518 Detection. Part number: 21518 Declaration of conformity Manufacturer:, The Way, Fowlmere, Cambridge, England. SG8 7UJ Product: CalCheck

More information

Propor tional Re lief Valve s

Propor tional Re lief Valve s www.swagelok.com Propor tional Re lief Valve s R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections Proportional Relief Valves

More information

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders The technical data described herein is for components of the Minimax Fire Products MX 30 Clean Agent System. For design, installation, and operation instructions, refer to the latest edition of the original

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

TEK-SUB 4800B. Submersible Level Transmitter.   Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter

More information

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1 NPT (Typ. Both Ends 2 Places) MODEL Float Control For Closed Tanks Accurate Liquid Level Control Fully Hydraulic Operation Simple Design, Easy Maintenance No Lubrication Necessary No Gears, No Mechanical Linkage Between Valve and Control

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES PAGE: 1 of 9 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 3.1 Canister Receipt 3.2 Canister Storage 4.0 INTERFERENCE AND POTENTIAL PROBLEMS

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

ECS Protector Nitrogen Inerting Vent (PAV-WN)

ECS Protector Nitrogen Inerting Vent (PAV-WN) ECS Protector (PAV-WN) U.S. Pat. No. 8,636,023, 9,526,933 and 9,717,935 B2 Specifications Stock Number: Service Pressure: Regulator Setting: System Connection: Temperature Range: Dimensions: Weight: Clear

More information

PRODUCT GUIDE Spring 2015

PRODUCT GUIDE Spring 2015 PRODUCT GUIDE Spring 2015 A COMPANY FOUNDED ON SERVICE During his 35 year tenure in the compressed gas and welding supply business, George Bennett identified service as the core value that leads to success.

More information

Flexible Metal Hose Products

Flexible Metal Hose Products Flexible Metal Hose Products Specialty Flexible Hose Solutions of Stainless Steel The AEROCOM Advantage Aerocom offers engineered solutions that address specific flexible piping challenges such as vibration,

More information

Model 4000 Pressure Controller

Model 4000 Pressure Controller FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum

More information

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits

LGSS Liquefied Gas & VSS Vapor (Gas) LGSS VSS LGSS. Features and Benefits N LGSS Liquefied Gas & VSS Vapor (Gas) Sampling Systems The SENSOR Cylinder Sampling Systems allow collection of samples from gas and light liquid hydrocarbon applications in a manner that is safe to both

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1003 - REVISED: 2009 Water Pressure Reducing Valves for Domestic Water Distribution Systems MANUFACTURER: CONTACT

More information

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility,

More information

6890 GC Site Preparation

6890 GC Site Preparation 6890 GC Site Preparation (a16011) This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this material. The information

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP Installation, Operation, and Maintenance Manual Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model The information in this manual has been carefully checked for

More information

MEDICAL EQUIPMENT CATALOG

MEDICAL EQUIPMENT CATALOG THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications

More information

High-Purity. Ball Valves

High-Purity. Ball Valves High-Purity s Components MANUFACTURING ASSEMBLY TESTING HP High-Purity s CFOS Applications Cost-effective systems where cleaning for oxygen-grade services are required, such as: Clean-Dry Air (CDA), Oil-Free

More information

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. BULLETIN 20-7000 ROTAMETERS PURGE FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. INTRODUCTION McCrometer purge rotameters are precision-made instruments designed to accurately

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

WHEATLEY Series 822/820 Swing Check Valve

WHEATLEY Series 822/820 Swing Check Valve Document Number: TC003001-12 Revision: 02 WHEATLEY Series 822/820 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...4 INSTALLATION AND OPERATION

More information

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

VCO O-Ring Face Seal Fittings

VCO O-Ring Face Seal Fittings O-Ring Face Seal Fittings www.swagelok.com O-Ring Face Seal Fittings /8 to sizes 36 or 36L stainless steel, NPT, S thread, and weld connections 2 Weld, VR,, Pipe, and Vacuum Fittings ontents Technical

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE

More information

HP/UHP Spring-Loaded Regulator

HP/UHP Spring-Loaded Regulator Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants

More information

92302 Liquid Level Indicators

92302 Liquid Level Indicators PRODUCT DATA SHEET Low cost and simple installation Accurate to ± 1 inch Choice of standard materials to accommodate most installations Extremely visible numerals and graduations Durable and reliable construction

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

First Stage Regulators

First Stage Regulators DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to

More information

RESIDENTIAL AND COMMERCIAL REGULATORS FOR ABNORMAL OPERATING CONDITIONS (AOC) WITH 3 FOOT CLEARANCE INSTALLATION REQUIREMENTS.

RESIDENTIAL AND COMMERCIAL REGULATORS FOR ABNORMAL OPERATING CONDITIONS (AOC) WITH 3 FOOT CLEARANCE INSTALLATION REQUIREMENTS. RESIDENTIAL AND COMMERCIAL REGULATORS FOR ABNORMAL OPERATING CONDITIONS (AOC) WITH 3 FOOT CLEARANCE INSTALLATION REQUIREMENTS Presented by Jon Beam Equipment Controls Company 3 FOOT ABNORMAL OPERATING

More information

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES PAGE: 1 of 14 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE 4.0 INTERFERENCE AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS

More information

HOSE & FLEXIBLE TUBING

HOSE & FLEXIBLE TUBING http://southwest.swagelok.com HOSE & FLEXIBLE TUBING PROVIDED BY SWAGELOK SOUTHWEST SWAGELOK SOUTHWEST Swagelok Hose and Flexible Tubing Metal Hose & Tubing FX Series Metal Hose FM Series Metal Hose FJ

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Operating Instructions

Operating Instructions Operating Instructions Multifunction Valve Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Dimensions... 4 Installation...2-3 Description of Controls & Operation... 3 Page Helpful

More information

Calibration and Switching Module

Calibration and Switching Module Calibration and Switching Module Application Guide A Swagelok Pre-Engineered Subsystem Pre-engineered subsystems available in weeks, not months. Field-tested design ensures optimum system performance.

More information

RHPS Series PRV 6 User Manual

RHPS Series PRV 6 User Manual RHPS Series PRV 6 User Manual Read the complete manual before installing and using the valve. 1 WARNING Before removing a valve from the system for service, you must depressurize system purge the system

More information

6301 TYPE CAST IRON SAFETY VALVES

6301 TYPE CAST IRON SAFETY VALVES Pressure (bar) 6301 TYPE CAST IRON SAFETY VALVES FEATURES The 6301 type safety valve is a device designed to protect installations against possible overpressure. It operates automatically and closes when

More information

Micro Motion 7812 Fiscal Gas Density Meter

Micro Motion 7812 Fiscal Gas Density Meter Product Data Sheet PS-001162, Rev. B April 2009 Micro Motion 7812 Fiscal Gas Density Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

2 Sentry MCL Installation, Operation & Maintenance

2 Sentry MCL Installation, Operation & Maintenance Gas Liquid & Slurry Solid & Powder Steam & Water Installation, Operation & Maintenance Manual Original Instructions Liquid Sampling Manual Low-Emission Samplers S-GA-IOM-00249-7 11-17 Sentry MCL 966 Blue

More information

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869 Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869-1 - 115.6020.15 These instructions describe the installation, operation and maintenance of the subject equipment.

More information

A NEW APPROACH FOR SEMICONDUCTOR INSTALLATIONS

A NEW APPROACH FOR SEMICONDUCTOR INSTALLATIONS A NEW APPROACH FOR SEMICONDUCTOR INSTALLATIONS A CARTEN DOCKWEILER EVANS COOPERATION ENSURING THE HIGHEST QUALITY SURFACE AVAILABLE THE R4i-LATERAL READY FOR INSTALLATION has been designed to meet all

More information

DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP-2000

DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP-2000 DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP-2000 DP-2000 INSTRUCTION & OPERATING MANUAL Version: 09092002 1 Table Of Contents 1. Introduction 3 2. System Components 3 3. Theory of Operation

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1048 - REVISED: 2009 Double Check Detector Fire Protection Backflow Prevention Assemblies Separate, complete laboratory

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints Guideline No.P-04 (201510) P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints Issued date: 20 th October 2015 China Classification Society Foreword This Guideline is a part of CCS

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

INSTRUMENTATION VALVES

INSTRUMENTATION VALVES INSTRUMENTATION VALVES INSTRUMENTATION BALL VALVES INTEGRAL-BONNET NEEDLE VALVES TOGGLE VALVES (TG Series) CHECK VALVES (CHV Series: For General Industry) RELIEF VALVES (RVL/RVH Series) INSTRUMENTATION

More information

Neotecha Tank Sampling Sapro

Neotecha Tank Sampling Sapro Tank sampling system for representative sampling without process interruption Features The sampling system assures a true representative sample every time without process interruption. The sampling system

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010 LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants

More information

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY

ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY ENSURING AN ACCURATE RESULT IN AN ANALYTICAL INSTRUMENTATION SYSTEM PART 1: UNDERSTANDING AND MEASURING TIME DELAY Process measurements are instantaneous, but analyzer responses never are. From the tap

More information

Pressure and Flow Control Valves DBGM, German and European Patents

Pressure and Flow Control Valves DBGM, German and European Patents Pressure and Flow Control Valves DBGM, German and European Patents Absolutely Reliable Pressure and Flow Control In water mains of sizes DN 50 to DN 150, ERHARD Control Valves in straight or angle pattern

More information

TECHNIQUES OF COMPOSITE GAS SAMPLING. David J. Fish. Welker Engineering Company P. O. Box 138 Sugar Land, Texas U. S. A.

TECHNIQUES OF COMPOSITE GAS SAMPLING. David J. Fish. Welker Engineering Company P. O. Box 138 Sugar Land, Texas U. S. A. TECHNIQUES OF COMPOSITE GAS SAMPLING David J. Fish Welker Engineering Company P. O. Box 138 Sugar Land, Texas 77487-0138 U. S. A. INTRODUCTION The level of interest in effective and accurate gas sampling

More information

Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications

Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications Bulletin CT Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications CT (Circular Tank) COLLECTORS... especially effective for dusting problems in drying, grinding and

More information

Trifecta High-Pressure Systems

Trifecta High-Pressure Systems Trifecta High-Pressure Systems CONSULTING SYSTEM DESIGN INSTALLATION COMMISSIONING TRAINING Trifecta Product Catalog www.chartindustries.com TABLE OF CONTENTS About Chart Inc. 3 Trifecta Applications &

More information

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG) Page 1 of 10 CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG) 1. SCOPE 1.1 To provide definitive requirements for HIGH PRESSURE PNEUMATIC testing of piping systems according to ASME B31.3. This

More information

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) 1 APPLICABILITY Exhibit 4 Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) Definitions common to all certification and test procedures

More information

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG A C E D SB-8520.2 1800CPB2 Service Regulators Maximum Inlet 125 PSIG AMC Quality System QMI is Accredited by: C R E D I T ISO 9001 Certified Certificate #006697 R E ANSI RAB G I S T R A R Dutch Council

More information

CAPITAL CONTROLS SERIES NXT3000

CAPITAL CONTROLS SERIES NXT3000 CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing

More information

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100 Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS For 3D Instruments Direct Drive Pressure Gauges 3D Instruments Inc., 15542 Chemical Lane, Huntington Beach, CA, 92649, U.S.A. Tel. (714) 894-5351, Fax. (714) 895-4309

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE MODELS RV-1 RV-2 RV-2CP RV-3 DRAWING NUMBERS AD017A[ ] AD018A[ ] AD020A[ ] AD282BO MANUAL NUMBER IOM-033 REVISION Rev. E, 3/28/2016 TABLE

More information

Piped Air SCBA Refilling System Standard

Piped Air SCBA Refilling System Standard WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Piped Air SCBA Refilling System Standard SCOPE: This specification

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

SOLFRUNT Model /2" (63mm) and 4" (100mm) Stainless Steel Gauges

SOLFRUNT Model /2 (63mm) and 4 (100mm) Stainless Steel Gauges LFG - 14 LIQUID FILLED GAUGES SOLID FRONT STYLE SOLFRUNT Model 659 2-1/2" (63) and 4" (100) Stainless Steel Gauges DESCRIPTION When safety is your top priority, AMETEK U.S. Gauge offers the Model 659 Series

More information

Model Series 62 Constant Differential Relay

Model Series 62 Constant Differential Relay Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

TECHNIQUES OF COMPOSITE SAMPLING. Kris Kimmel. YZ Systems, Inc Pollok Drive Conroe, Texas 77303

TECHNIQUES OF COMPOSITE SAMPLING. Kris Kimmel. YZ Systems, Inc Pollok Drive Conroe, Texas 77303 TECHNIQUES OF COMPOSITE SAMPLING Kris Kimmel YZ Systems, Inc. 3101 Pollok Drive Conroe, Texas 77303 Introduction Since a gas sampling system can be referred to as a cash register it is very important that

More information

TECHNIQUES FOR NATURAL GAS SPOT SAMPLING

TECHNIQUES FOR NATURAL GAS SPOT SAMPLING TECHNIQUES FOR NATURAL GAS SPOT SAMPLING Written by: David J. Fish Senior Vice President Presented by: Collin Pawlak Inside Sales Manager Welker 13839 West Bellfort Sugar Land, TX 77498-1671 PURPOSE The

More information

Basic & Controlled Atmosphere Glove Boxes

Basic & Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical

More information

INDEX. Table of Contents. Warranty. ISO 9001 Certificate. Product Selection Guide

INDEX. Table of Contents. Warranty. ISO 9001 Certificate. Product Selection Guide INDEX Table of Contents Warranty ISO 9001 Certificate Product Selection Guide TABLE OF CONTENTS Model Number Model Description...........................................Page Number INDEX TABLE OF CONTENTS............................................i

More information

High-Flow, Manual Gas Pressure Regulators

High-Flow, Manual Gas Pressure Regulators High-Flow, Manual Gas Pressure Regulators HF Series 1 www.swagelok.com High-Flow, Manual Gas Pressure Regulators HF Series Compact size with flow rates up to 2 std L/min Maximum inlet pressures up to 5

More information

Diaphragm pressure gauge guard MDM 902

Diaphragm pressure gauge guard MDM 902 Diaphragm pressure gauge guard MDM 90 Nominal size DN 0 5 Pressure PN 10 bar Features Pressure measurement up to 10 bar EPDM diaphragm with PTFE coating on the side in contact with the medium Reliable

More information

DynaPak 2000L System Support Manual Version

DynaPak 2000L System Support Manual Version DynaPak 2000L System Support Manual Version 04032001 2 Table Of Contents 1. Introduction 3 2. System Components 3 3. Theory of Operation 4 4. Sampler Location 5 5. Sampler Installation 6 6. Sample Vessel

More information

Type 4660 High-Low Pressure Pilot

Type 4660 High-Low Pressure Pilot Product Bulletin Type 4660 High-Low Pressure Pilot The Type 4660 pneumatic high-low pressure pilot (figure 1) activates safety shutdown systems for flowlines, production vessels, and compressors. This

More information