Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Size: px
Start display at page:

Download "Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems"

Transcription

1 Pneumatic Retractable Fittings SensoGate W 3 H Sanitary pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation offers genuine plug & play. The central multi-plug is linked via a single connection to all rinsing, cleaning, and calibration media as well as the control air and limit position mechanisms. Media entrainment is minimized and the limit-position mechanism is protected. SensoGate with multi-plug Conventional retractable fittings: Tangled hoses (left) and deposits on unprotected limit-position mechanism (right) Systematic, Fully utomatic Liquid nalysis The combination of the SensoGate W 3 H retractable fitting with the Uniclean 9 (cleaning) or Unical 9 (cleaning and calibration) control units and the Protos 34 measuring system enables fully automated measuring stations with high precision and reliability. Maximum stability and precision due to patented metering-pump technology with separate routing of the media. Short duration measurements and regular cleaning enable longer sensor life. The production process is not interrupted by automatic cleaning or calibration. The system offers the high levels of safety by monitoring the compressed air and water supply, the probe position, and the buffer and cleaning solution levels. 23

2 For up-to-date For information, up-to-date information, please visit please visit dditional Media Connection for Superheated Steam or Chemical pplications dditional media connection separated by integrated check valve No dead spots Easy access Valve with high flow rate Uncompromising Sanitary Design of the Calibration Chamber is EHEDG-certified. This applies not just to the process-wetted parts but also the cleaning chamber. This means that it is suitable for unrestricted use in pharmaceutical and food applications. This also allows validation in FD regulated production processes. The only part of the immersion tube which comes in contact with the process is that part which was previously sterilized in the rinsing chamber. Sterilizable and cleanable calibration chamber with special flow body Facts EHEDG/FD-certified for all process-wetted parts including rinsing/calibration chamber Directed flow rinses the process seal from the process side as well as from the inside of the fitting Cyclone cleaning effect Double gaskets with leakage bores prevent microbial contamination of the drive Broad applications in sanitary conditions Process-wetted parts: stainless steel 36 SS, electropolished SIP and CIP compatible in process SIP and CIP of calibration chamber and cleaning connections Fast and easy replacement of calibration chamber and insertion tube ll maintenance can be performed on site Superior sensor immersion depth Standard sensor length (225 mm) even for large immersion depths Multiple process connections available Modular design Special version for sensors with pressurized liquid electrolyte Low cost, simple installation, operation, and maintenance Protective cleaning of seals for long service life SensoLock for high operational safety Integrated limit switches FD 23

3 Pneumatic Retractable Fittings SensoGate W 3 H for sanitary applications vailable Versions Material: 36 SS, electropolished Variants: short and long immersion depths; liquid- or gel-filled sensors; adapter for free hose connection Ball bearings for easy detachability Process adaptations: Dairy pipe DN 5 Ingold socket 25 mm Clamp.5; 3.5; Varivent DN 5 8 BioControl DN 5, DN 65, mounted in a Varivent housing W 3 H Clamp, short W 3 H Clamp, long W 3 H Varivent W 3 H Dairy pipe W 3 H Ingold socket 36 SS W 3 H Ingold socket, liquid-electrolyte sensors 232

4 For up-to-date information, please visit Specifications mbient temperature Permissible process temp Permitted process pressure during movement Permissible static pressure ir supply Effective immersion depth Total immersion depth incl. immersion tube 4 58 F (5 7 C) F (5 4 C) 87 psi (6 bar) gauge pressure at 284 F (4 C) 232 psi (6 bar) (4 F (4 C)) in service position 58 psi (4 7 bar), filtered 25 µm, oil- and condensate-free 33 mm, measured from lower edge of flange to sensor tip (Varivent version) 46 mm Process adaptations*} dairy-pipe screw joint, DN 5 / DN 65 / DN 8 Ingold socket, 36 SS, 25 mm (G /4;) Clamp 2;, 36 SS Varivent, DN 5 25, 36 SS Sensors Rinse-medium inlet Rinse-medium outlet Rinse function Process-wetted materials 225 mm, Pg-3.5 coupling, 25 mm for pressurized liquid-electrolyte sensors ) for Unical 9 / Uniclean 9: Connection with hose grommet and coupling 2) for manual control: ZU 63 / ZU 646 connection: hose grommet with coupling seal rinsing during stroke movement stainless steel, 36 SS Enclosure stainless steel,.457 Ingress protection IP 66 Connection to Uniclean 9 / Unical 9 Sensor protection in the process Limit switches Certificates * ) Special connections on request compact multiplug connection integrated in immersion tube noncontacting electrical limit-position control in conjunction with Uniclean 9 / Unical 9 / ZU Material Certificate (optional) TEX II GD c II 233

5 Pneumatic Retractable Fittings SensoGate W 3 H for sanitary applications Product Line Order No. Sanitary sensor lock-gate, pneumatic W 3H / _ Explosion protection for hazardous area Zone without X N Sensor Gasket material solid electrolyte liquid electrolyte (pressurization possible) elastomeric ring set F, FKM elastomeric ring set E, EPDM FD elastomeric ring set G, FFKM process-wetted elastomeric ring set H, FFKM complete F E G H Process-wetted materials*} 36 SS / 36 SS / 36 SS (electropolished) G Process adaptation dairy pipe, DN 5 dairy pipe, DN 65 dairy pipe, DN 8 Ingold socket, 36 SS, 25 mm (G /4;) Ingold socket, sanitary,36 SS, 25 mm (G /4;) Clamp.5;, 36 SS Clamp 2;, 36 SS Clamp 2.5;, 36 SS Clamp 3;, 36 SS Clamp 3.5;, 36 SS Varivent, 36 SS, for pipe from DN 5 Varivent, 36 SS, for pipe from DN 5 short, from DN 8 long BioControl DN 5 BioControl DN 65 C C C H H J J J J J V V L L Immersion depth short long B Connection media connection, PEEK media connection, PEEK, integr. connection of add. medium B C Special variant without equipped with special grease (provided by customer) with scraper ring, reinforced version, PTFE/PEEK (ZU 76) 3 * ) Material combinations: Process-wetted part of calibration chamber/rinse-wetted part of calibration chamber/immersion tube 234

6 For up-to-date information, please visit ccessories Order No. Service set basic equipment ZU 68 maintenance, repair, retrofit ZU 74 calibration chamber ZU 754 Mounting aid for 2 x 2.5 O-rings ZU 747 for scraper ring ZU 746 Bellows version for liquid-electrolyte sensors ZU 739 dapter for free hose connection PP/EPDM (incl. electric feedback) ZU 733 PP/EPDM (without electric feedback) ZU 734 PEEK/EPDM (incl. electric feedback) ZU 742 Material Certificate 3. ZU 78 ir supply for pressurized sensors, 7 58 psi (.5 4 bars) ZU 67/ for pressurized sensors, 4.5 psi ( 7 bars) ZU 67/2 Hose 2 m (extension for ZU 67) ZU 73 Flange protectors PEEK / FFKM DN 8 ZU 755 PEEK / FFKM DN ZU 756 PVDF / FFKM DN 8 ZU 757 PVDF / FFKM DN ZU 758 Safety weld-in socket, straight, 4 mm for tank wall ZU 77 for pipe, DN 5 ZU 77/DN5 for pipe, DN 65 for pipe, DN 8 for pipe, DN ZU 77/DN65 ZU 77/DN8 ZU 77/DN Safety weld-in socket, beveled 5, 4 mm for tank wall ZU 78 for pipe, DN 5 ZU 78/DN5 for pipe, DN 65 for pipe, DN 8 for pipe, DN ZU 78/DN65 ZU 78/DN8 ZU 78/DN 235

7 Pneumatic Retractable Fittings SensoGate W 3 H for sanitary applications Gaskets Set Contact (process/rinse medium) Order No. Dairy pipe, Varivent, clamp E/ EPDM FD ZU 7/ E/2 EPDM FD / EPDM FD ZU 7/2 F/ FKM FD ZU 697/ F/2 FKM FD / FKM FD ZU 697/2 G/ FFKM FD ZU 766/ G/2 FFKM FD / EPDM FD ZU 766/2 H FFKM FD / FFKM FD ZU 767 Ingold socket E/ EPDM FD ZU 74/ E/2 EPDM FD / EPDM FD ZU 74/2 F/ FKM FD ZU 73/ F/2 FKM FD / FKM FD ZU 73/2 G/ FFKM FD ZU 768/ G/2 FFKM FD / EPDM FD ZU 768/2 H FFKM / FFKM ZU 769 Spare Parts Order No. Immersion tube, short 36 SS ZU

8 For up-to-date information, please visit Dimensional Drawings Installation dimensions for for sensors with liquid electrolyte Installation dimensions for for sensors with gel electrolyte Process adaptation for Varivent DN 5, short immersion depth Sensor 25 mm Sensor 225 mm (27.5) (47) Clearance for sensor installation pprox. 88 mm for short immersion depth pprox. 855 mm for long immersion depth pprox. 457 mm for short immersion depth pprox. 432 mm for long immersion depth Clearance for sensor installation pprox. 54 mm for short immersion depth pprox. 55 mm for long immersion depth pprox. 259 mm for short immersion depth pprox. 234 mm for long immersion depth Process adaptation for Varivent from DN 8, long immersion depth Process adaptation for Varivent from DN 65, short immersion depth (57.5) (32.5) (77) (52) 237

9 Pneumatic Retractable Fittings SensoGate W 3 H for sanitary applications Dimensional Drawings continued Process adaptation for TriClamp 2; 3.5;, long immersion depth Process adaptation for dairy pipe DN 85 DN 5, long immersion depth Process adaptation for Ingold socket, 25 mm Process adaptation for TriClamp ; 3.5;, short immersion depth Process adaptation for dairy pipe DN 85 DN 5, short immersion depth Process adaptation for BioControl DN 5/DN ,5 (32.5) (52) ,

10 For up-to-date information, please visit 239

Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas

Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas Pneumatic Retractable Fittings Pharm Food SensoGate W 3 H Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas Easy installation and clear hose connections offers

More information

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems Pneumatic Retractable Fittings SensoGate WA 3 Pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation SensoGate WA 3 offers genuine plug & play. The

More information

Manual retractable fitting with safe-to-operate rotary drive

Manual retractable fitting with safe-to-operate rotary drive Manual Retractable Fittings SensoGate W M Manual retractable fitting with safe-to-operate rotary drive Revolutionary operation The SensoGate W M has a manual rotary drive, which enables the fitting to

More information

Pneumatic retractable fitting for simple commercially available control units or process applications

Pneumatic retractable fitting for simple commercially available control units or process applications Pneumatic Retractable Fittings hem Energy Pharm Food Water SensoGate W 3 Pneumatic retractable fitting for simple commercially available control units or process applications Variable and reasonably priced

More information

Armatures for analytical probes

Armatures for analytical probes Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type

More information

ph measuring system for hygienic process applications

ph measuring system for hygienic process applications ph measuring system for hygienic process applications Sterile design, CIP-compatible, in-line sterilizable Extremely robust and unbreakable construction Extremely long service life Long calibration intervals

More information

Pressure Transmitter P41

Pressure Transmitter P41 SENSORS FOR AND BIOPHARMA. Product Information P41 Pressure Transmitter P41 Application/Specified usage Pressure measurement in pipes and tanks For process temperatures up to 250 C (428 F) with optional

More information

Overview. VARICOVER product recovery systems. Special features. Recover the value, reduce the waste! Design with no dead-zones.

Overview. VARICOVER product recovery systems. Special features. Recover the value, reduce the waste! Design with no dead-zones. Overview Recover the value, reduce the waste! Special features Design with no dead-zones CIP/SIP-able Reduced product loss Reduced cleaning media and water consumption Reduced waste water load Reduced

More information

Valves. Diaphragm shut-off valves, kidney-type

Valves. Diaphragm shut-off valves, kidney-type Valves Diaphragm shut-off valves, kidney-type Application When leakage of even the smallest quantities must be avoided with certainty For maximum requirements to operating safety For maximum requirements

More information

SÜDMO ASEPTIC PROCESS VALVE SECURE FOOD & BEVERAGE ASEPTIC PROCESS VALVE SECURE

SÜDMO ASEPTIC PROCESS VALVE SECURE FOOD & BEVERAGE ASEPTIC PROCESS VALVE SECURE SÜDMO ASEPTIC PROCESS VALVE SECURE FOOD & BEVERAGE ASEPTIC PROCESS VALVE SECURE THE ALL NEW ASEPTIC PROCESS VALVE SERIES SECURE Based on its many years of experience in valve construction, Südmo offers

More information

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction 7 Before installation these instructions must be fully read and understood 1.4 Illegal technical changes It is illegal to do mechanical changes of the design of the Sapro tank valve, or to use parts of

More information

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design

More information

VSR modulating valves with membrane actuator

VSR modulating valves with membrane actuator Modulating valves are used in process technology to control process parameters such as temperature, pressure or flow when handling liquid and gaseous media. uth's team of design and process engineers have

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

JSHM Series Hand Metering Valves

JSHM Series Hand Metering Valves Hand metering valve for precise manual control of iopharm and Pharmaceutical gas or liquids The JSHM Series allows precision manual adjustment of pharmaceutical liquid and gas flows. These valves are most

More information

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure

More information

Technical Information Cleanfit CUA451

Technical Information Cleanfit CUA451 TI00369C/07/EN/13.13 71238305 Products Solutions Services Technical Information Cleanfit CUA451 Manually operated retractable assembly for water, wastewater and process media Application Drinking water

More information

Instruction presentation Special valves

Instruction presentation Special valves Instruction presentation Special valves 1 Special Valves 2 Special Valves Index of contents 1. Overview special valves 2. Description Gauge Guard 3. Description Water Jet Pumps 4. Description Venting and

More information

MEASURING INSTRUMENTS Pressure Gauge T-Piece...77 Pressure Gauge TC 25.0, connection below...78 Pressure Gauge TC 25.0, connection behind...

MEASURING INSTRUMENTS Pressure Gauge T-Piece...77 Pressure Gauge TC 25.0, connection below...78 Pressure Gauge TC 25.0, connection behind... Pressure Gauge T-Piece...77 Pressure Gauge TC 25.0, connection below...78 Pressure Gauge TC 25.0, connection behind...79 Pressure Gauge TC 50.5, connection below...80 Pressure Gauge TC 50.5, connection

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER Table of contents 1 Security and safety measures... 5 1.1 General safety instructions... 5 1.2 Intended use... 5 1.3 Danger zones and residual

More information

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version Series 44 Self-operated Pressure Regulators Type 44-1 B Pressure Reducing Valve Type 44-6 B Excess Pressure Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT

More information

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65 Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode

More information

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions Before installation these instructions must be fully read and understood 2 Safety Please read these instructions carefully. 2.1 General danger potential Not paying attention to this instruction Incautious

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design

More information

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves JSRH Series High Flow Bio-Pharma Clean Gas Pressure Reducing Valves The JSRH Series high purity gas pressure regulator was designed and built specifically for Bio-Pharma gas applications. It may also be

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries. VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

Tank Blanketing Regulators

Tank Blanketing Regulators Tank Blanketing Regulators Low-Pressure Reducing Regulator Type BR Low-Pressure Relief Valve Type BS Description Tank blanketing, or padding, is the process and practice of covering a stored commodity,

More information

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET 2/2-way valve with piston actuator and PTFE bellows 2/2-Wege Ventil mit Kolbenantrieb und PTFE-Faltenbalg Vanne 2/2 voies avec entraînement à piston

More information

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

Technical Information Conducal CLY421

Technical Information Conducal CLY421 TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified

More information

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features Vortex flowmeters introduction Product review s Key product features This document should not be duplicated, used, distributed, or disclosed for any purpose unless authorized by Siemens. Page 1 Vortex

More information

Tank Blanketing Regulators

Tank Blanketing Regulators Tank Blanketing Regulators Low-Pressure Reducing Regulator Type BR Low-Pressure Relief Valve Type BS Description Tank blanketing, or padding, is the process and practice of covering a stored commodity,

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement

More information

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3, 4, 6 Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with

More information

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves. JSR Series High Purity Bio-Pharma Gas Pressure Reducing Valves JSR is the first high purity gas pressure regulator designed and built specifically for hygienic, ASME BPE gas applications. Traditionally,

More information

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63 Ultrasonic 58 Overview VEGASON 60 VEGASON 61, 62, 63 57 Overview VEGASON Area of application The ultrasonic sensors of the VEGASON series are suitable for non-contact level measurement of liquids and bulk

More information

Cleanfit P CPA473. Technical Information. Retractable stainless steel process assembly with ball valve for ph and ORP electrodes

Cleanfit P CPA473. Technical Information. Retractable stainless steel process assembly with ball valve for ph and ORP electrodes Technical Information Cleanfit P CP473 Retractable staless steel process assembly with ball valve for ph and ORP electrodes pplication Chemical dustry Paper dustry Wastewater / dustrial water Power plants

More information

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY OXYFLEX - M T 2 3 5 / M T 3 0 0 M E M B R A N E D I S C D I F F U S ER UND GESELLSCHAFT FÜR UMWELT- VERFAHRENSTECHNIK MBH AERATION TECHNOLOGY von-drais-straße 7 D-55469 Simmern / Hunsrück Tel.: +49 6761

More information

PARTS & SERVICE. regulator (new) for NGW/ GBW applications. Rev. 02/2018 Id.No. DOK50026

PARTS & SERVICE. regulator (new) for NGW/ GBW applications. Rev. 02/2018 Id.No. DOK50026 PARTS & SERVICE Heating systems Retrofit instruction gas pressure regulator (new) for NGW/ GBW applications Rev. 02/2018 Id.No. DOK50026 Regulations / safety hints natural gas vehicles On behalf of the

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist INDEX Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR COMPRESSED AIR SAVING PRODUCTS Condensate Management Specialist Information provided herewith is believed to be accurate and reliable. However,

More information

Neotecha Tank Sampling Sapro

Neotecha Tank Sampling Sapro Tank sampling system for representative sampling without process interruption Features The sampling system assures a true representative sample every time without process interruption. The sampling system

More information

Retractable Process Assembly

Retractable Process Assembly BA 223C/07/en/07.03 51517648 CleanFit P CPA 472 Retractable Process Assembly Operating Instructions Quality made by Endress+Hauser ISO 9001 CleanFit P CPA 472 Table of contents 1 Safety instructions..............

More information

Technical Data Sheet T 2025

Technical Data Sheet T 2025 Self-operated emperature Regulators emperature Regulator ype 4 Valve closes when the temperature rises. emperature Regulator ype 4u Valve opens when the temperature rises. Balanced single-seated globe

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

ATS430 turbidity sensor Retractable insertion assembly

ATS430 turbidity sensor Retractable insertion assembly A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion

More information

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Operating Manual LTIA3E Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical

More information

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve Series Self-operated Pressure Regulators Type -6 B Excess Pressure Valve Application Set points from 0.2 to 20 bar with valves G ½, G ¾, and G as well as DN, DN 2, DN 0, and DN 0 Nominal pressure PN 2

More information

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

TECHNOLOGIES. M Series. Positive return metering pumps [API675] M Series Positive return metering pumps [API675] Hydraulic double diaphragm metering pump in AISI 316L stainless steel A line of plunger and hydraulic double diaphragm metering pumps designed according

More information

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance

More information

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm > Series CGPT self-centering parallel grippers with T-guide Series CGPT self-centering parallel grippers with T-guide Single and double acting, magnetic, self-centering Bores: ø 6, 20, 25, 32, 40 mm New

More information

HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL

HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL 1 CONTENTS 2 Introduction 2 2.1 Valve use 2 2.2 Application area 2 2.3 Incorrect use 2 3 Safety 2 4 Transport and storage 2 5 Installation instructions 2 5.1 Mounting 2 5.2 Installation into pipework 2

More information

Peak Biotech - Company & Product Presentation

Peak Biotech - Company & Product Presentation Peak Biotech - Company & Product Presentation July 2005 Peak Biotech Company & Product Presentation Peak Biotech Company Profile Location Jacob Nøhr Peak Biotech A/S was founded Kvistgaard, Denmark QA

More information

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves JSRH Series High Flow Bio-Pharma Clean Gas Pressure Reducing Valves The JSRH Series high purity gas pressure regulator was designed and built specifically for Bio-Pharma gas applications. It may also be

More information

Neotecha Tank Sampling Sapro

Neotecha Tank Sampling Sapro E Neotecha Tank Sampling Sapro Tank sampling system for representative sampling without process interruption Features The sampling system assures a true representative sample every time without process

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Air Amplifiers & SYSTEMS

Air Amplifiers & SYSTEMS Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer July 2011 OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer WARNING! Before operating this product, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Contact

More information

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik Dr. Thiedig Anlagen- und Analysentechnik DIGOX 5 CO In-line measurement of CO for constant product quality DIGOX 5 CO the robust system for CO measurement in the beverage industry The content of dissolved

More information

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846 CPVC Transition Fittings - Female Adapter STD4703BTLF12 1/2 CPVC X 1/2 FIP 25 250 CPVC Transition Fittings - Female Adapter STD4703BTLF34 3/4 CPVC X 3/4 FIP 25 250 CPVC Transition Fittings - Female Adapter

More information

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs. VACUUM & AIRLESS Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs. tions precision glassware solutions precision glassware solutions

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

SIP Fermentation System. (Pilot Scale) 10L / 30L / 50L System. Motor Manual or automatic control of constant agitation speed

SIP Fermentation System. (Pilot Scale) 10L / 30L / 50L System. Motor Manual or automatic control of constant agitation speed SIP Fermentation System (Pilot Scale) Motor Manual or automatic control of constant agitation speed 10L / 30L / 50L System Peristaltic Pump Uses four Watson Marlow built-in peristaltic pumps for all your

More information

Hydraulic hand test pump Models CPP700-H and CPP1000-H

Hydraulic hand test pump Models CPP700-H and CPP1000-H Calibration technology Hydraulic hand test pump Models CPP700-H and CPP1000-H WIKA data sheet CT 91.07 for further approvals see page 2 Applications Simple test pressure generation on site, in the laboratory

More information

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations

More information

kysimply Unique Single Seat

kysimply Unique Single Seat . kysimply Unique Single Seat Unique SSV Long Stroke General Information The new generation that meets the highest demands of your process in terms of hygiene and safety. Unique Single Seat Valves are

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222 PATENT #: 5,160,222 PHONE: (913)677-5777 FAX: (913)677-067 E-Mail : techair@techairinc.com www.techairinc.com CHECK-KLEEN DIVERTER A PNEUMATIC CONVEYING SYSTEM FLAP-CHECKS exposed to product air stream

More information

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating

More information

Operating Instructions

Operating Instructions Operating Instructions Multifunction Valve Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Dimensions... 4 Installation...2-3 Description of Controls & Operation... 3 Page Helpful

More information

14. Exploded View. Page 68

14. Exploded View. Page 68 14. Exploded View Page 68 15. View of housing Page 69 11. Spare Parts HY05 HY13 55 E-2124010 Keys for safety, set=2pc. 54 E-2124012 Safety lock incl. 2 keys 1 B-3204031 1 B-2204101 1 B-2204111 1 2 B-2204105

More information

ACTUATORS AND INSTRUMENTS

ACTUATORS AND INSTRUMENTS ACTUATORS AND 03 ADVANCED ACTUATORS AND FOR A COMPLETE VALVE CONTROL SOLUTION Koso Kent Introl LIMITED (KKI) supplies a full range of advanced actuators and associated instrumentation to complement its

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

Sterile Sampling Bottle Assembly

Sterile Sampling Bottle Assembly Sterile Sampling Bottle Assembly ALLOWS CApTURINg AND HANDLINg OF LIQUID STERILE product SAMpLES SIP/CIP Fully Autoclavable Assembly Stainless Steel, PVDF Construction Borosilicate Bottle Steam Cleanable

More information

PMO 2.0 pee em ō too point ō

PMO 2.0 pee em ō too point ō and learning to communicate> PMO 2.0 pee em ō too point ō noun (pl. PMOs 2.0) : the next generation of 24/7 PMO Valve, the hygienic mixproof valves for the dairy dairy industry, revolutionized by GEA Tuchenhagen.

More information

Company Profile.. About Sammi Machinery

Company Profile.. About Sammi Machinery Company Profile.. About Sammi Machinery What is Line Blind Valve? Line blinding has been used to pipe lines in various indutries wherever either positive shut-off is most concerned or full flow should

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Hydraulic pressure balance Model CPB5800

Hydraulic pressure balance Model CPB5800 Calibration technology Hydraulic pressure balance Model CPB5800 WIKA data sheet CT 31.11 for further approvals see page 8 Applications Primary standard for calibrating the pressure scale in a hydraulic

More information

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps

More information

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34 Pressure Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34 WIKA data sheet DS 95.18 Applications Chemical/petrochemical industry, oil/gas industries

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

Pressure Reducing Valve DMV 750

Pressure Reducing Valve DMV 750 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction

More information

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

BIMBAR INFLATABLE PACKERS AND ACCESSORIES BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced

More information

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp-, p- and T-Sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Gas Massflowmeter Venturi- and Probe Type Precise

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information