Series 275 Granville-Phillips Mini-Convectron Module with Differential Output Amplifier

Size: px
Start display at page:

Download "Series 275 Granville-Phillips Mini-Convectron Module with Differential Output Amplifier"

Transcription

1 Series 275 Granville-Phillips Mini-Convectron Module with Differential Output Amplifier Instruction Manual Instruction manual part number Revision D - September 2014

2

3 Series 275 Granville-Phillips Mini-Convectron Module with Differential Amplifier Output For Customer Service or Technical Support 24 hours per day, 7 days per week, every day of the year including holidays: Phone: or MKS, Granville-Phillips Division 6450 Dry Creek Parkway Longmont, CO USA Phone: or FAX: gp-csr@mksinst.com Corporate Office MKS Instruments, Inc. 2 Tech Drive, Suite 201 Andover, MA USA Phone: Instruction Manual 2014 MKS Instruments, Inc. All rights reserved. Granville-Phillips and Convectron are registered trademarks of MKS Instruments, Inc. All other trademarks and registered trademarks are the properties of their respective owners.

4 This instruction manual is for use with catalog numbers & (20) GQ-T.

5 Table of Contents Chapter 1 Safety and Introduction Safety Introduction Reading and Following Instructions Explosion / Implosion System Grounding Operation Service Guidelines Receiving Inspection Domestic Shipments International Shipments Damaged Material Specifications Chapter 2 Installation Important Precautions for Mini-Convectron Installation Mounting Location and Orientation Location Environment Grounding Dimensions I/O Connector Wiring Chapter 3 Operation Theory of Operation Front Panel Differential Analog Output Use with Gases other than N 2 and Air Chapter 4 Service/Maintenance General Information Mini-Convectron Disassembly Troubleshooting Convectron Gauge Bakeout Instructions Cleaning a Convectron Gauge Returning a Mini-Convectron Module for Service Mini-Convectron Module with Differential Output Amplifier 5

6 6 Mini-Convectron Module with Differential Output Amplifier

7 Chapter 1 Safety and Introduction 1.1 Safety Introduction START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS AND NOTES collected here for your convenience and repeated with additional information at appropriate points in these instructions. These safety alert symbols in this manual or on the Product rear panel, mean caution personal safety, property damage or danger from electric shock. Read these instructions carefully. NOTE: These instructions do not and cannot provide for every contingency that may arise in connection with the installation, operation, or maintenance of this product. If you require further assistance, contact MKS, Granville-Phillips Division at the address on the title page of this manual. This product was designed and tested to offer reasonably safe service provided it is installed, operated, and serviced in strict accordance with these safety instructions. Failure to comply with these instructions may result in serious personal injury, including death, or property damage. In these instructions the word product refers to the Mini-Convectron Module and all of its approved parts and accessories. Table 1-1 Term Module Terms Describing the Mini-Convectron Module and Components Description The Mini-Convectron vacuum gauge module, which contains a Convectron convection-enhanced Pirani heat-loss pressure gauge. Convectron Gauge The Convectron convection-enhanced Pirani heat-loss gauge, which measures pressure within the vacuum chamber. The instructions in this User Manual explain how to install, operate, and maintain the Granville-Phillips Mini-Convectron vacuum gauge module. This chapter explains the caution and warning statements used throughout the manual which must be adhered to at all times, your responsibility to read and follow all instructions, how to contact customer service, and product specifications. Chapter 2 explains how to install and connect the module. Mini-Convectron Module with Differential Output Amplifier 7

8 Chapter 1 Chapter 3 explains the theory of operation, how to operate the module, and using the module with gases other than N 2 or Air. Chapter 4 explains troubleshooting, Convectron gauge testing, removal and replacement, and module return-for-repair procedures. 1.2 Reading and Following Instructions You must comply with all instructions while you are installing, operating, or maintaining the module. Failure to comply with the instructions violates standards of design, manufacture, and intended use of the module. MKS Instruments, Inc. disclaims all liability for the customer's failure to comply with the instructions. Read instructions Read all instructions before installing or operating the product. Follow instructions Follow all installation, operating and maintenance instructions. Retain instructions Retain the instructions for future reference. Heed warnings and cautions Adhere to all warnings and caution statements on the product and in these instructions. Parts and accessories Install only those replacement parts and accessories that are recommended by Granville-Phillips. Substitution of parts is hazardous. CAUTION Caution statements alert you to hazards or unsafe practices that could result in minor personal injury or property damage. Each caution statement explains what you must do to prevent or avoid the potential result of the specified hazard or unsafe practice. WARNING Warning statements alert you to hazards or unsafe practices that could result in severe property damage or personal injury due to electrical shock, fire, or explosion. Each warning statement explains what you must do to prevent or avoid the potential result of the specified hazard or unsafe practice. 8 Mini-Convectron Module with Differential Output Amplifier

9 Safety and Introduction Caution and warning statements comply with American Institute of Standards Z through Z , which set forth voluntary practices regarding the content and appearance of safety signs, symbols, and labels. Each caution or warning statement explains: a. The specific hazard that you must prevent or unsafe practice that you must avoid, b. The potential result of your failure to prevent the specified hazard or avoid the unsafe practice, and c. What you must do to prevent the specified hazardous result. WARNING The fumes from solvents such as trichloroethylene, perchloroethylene, toluene, and acetone can be dangerous to health if inhaled. Use only in well ventilated areas exhausted to the outdoors. Acetone and toluene are highly flammable and should not be used near an open flame or energized electrical equipment. 1.3 Explosion / Implosion WARNING If used improperly, Mini Convectron Gauges can supply misleading pressure indications that can result in dangerous overpressure conditions within the system. Do not operate in an explosive atmosphere. Do not operate the product in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard. Do not use the product to measure the pressure of explosive or combustible gases or gas mixtures. The sensor wire of the Mini Convectron Gauge normally operates at only 125 C, but it is possible that Controller malfunction can raise the sensor temperature above the ignition temperature of combustible mixtures. Danger of explosion or inadvertent venting to atmosphere exists on all vacuum systems which incorporate gas sources or involve processes capable of pressurizing the system above safe limits. Mini-Convectron Module with Differential Output Amplifier 9

10 Chapter 1 Danger of injury to personnel and damage to equipment exists on all vacuum systems that incorporate gas sources or involve processes capable of pressuring the system above the limits it can safely withstand. For example, danger of explosion in a vacuum system exists during backfilling from pressurized gas cylinders because many vacuum devices such as ionization gauge tubes, glass windows, glass belljars, etc., are not designed to be pressurized. WARNING If accurate conversion data is not used, or is improperly used, a potential overpressure explosion hazard can be created under certain conditions. Using the N 2 calibration to pressurize a vacuum system above about 1 Torr with certain other gases can cause dangerously high pressures which may cause explosion of the system. See the Chapter 4 before using with other gases. Series 275 instruments are furnished calibrated for N 2. They also measure the pressure of air correctly within the accuracy of the instrument. Do not attempt to use a Series 275 Gauge calibrated for N 2 to measure or control the pressure of other gases such as argon or CO 2, unless accurate conversion data for N 2 to the other gas is properly used. See Use with Gases other than N 2 and Air on page-23. A pressure relief valve should be installed in the system if the possibility of exceeding 1000 Torr (1333 mbar) exists. Suppliers of pressure relief valves and pressure relief disks are listed in Thomas Register under "Valves, Relief", and "Discs, Rupture". Confirm that these safety devices are properly installed before installing the the Mini-Convectron Module. In addition, check that (1) the proper gas cylinders are installed, (2) gas cylinder valve positions are correct on manual systems, and (3) the automation is correct on automated systems. 10 Mini-Convectron Module with Differential Output Amplifier

11 Safety and Introduction 1.4 System Grounding Grounding, though simple, is very important! Be certain that ground circuits are correctly used on your ion gauge power supplies, gauges, and vacuum chambers, regardless of their manufacturer. Safe operation of vacuum equipment, including the Mini-Convectron Module, requires grounding of all exposed conductors of the gauges, the controller and the vacuum system. Lethal Voltages may be established under some operating conditions unless correct grounding is provided. Ion producing equipment, such as ionization gauges, mass spectrometers, sputtering systems, etc., from many manufacturers may, under some conditions, provide sufficient electrical conduction via a plasma to couple a high voltage electrode potential to the vacuum chamber. If exposed conductive parts of the gauge, controller, and chamber are not properly grounded, they may attain a potential near that of the high voltage electrode during this coupling. Potential fatal electrical shock could then occur because of the high voltage between these exposed conductors and ground. 1.5 Operation It is the installer's responsibility to ensure that the automatic signals provided by the process control module are always used in a safe manner. Carefully check manual operation of the system and the setpoint programming before switching to automatic operation. Where an equipment malfunction could cause a hazardous situation, always provide for fail-safe operation. As an example, in an automatic backfill operation where a malfunction might cause high internal pressures, provide an appropriate pressure relief device. 1.6 Service Guidelines For customer service: Phone or , 8 AM to 5 PM Mountain Time Zone, excluding weekends within the USA. gp-csr@mksinst.com Additional service guidelines are given in the Service Chapter. Mini-Convectron Module with Differential Output Amplifier 11

12 Chapter Receiving Inspection Domestic Shipments International Shipments Damaged Material Inspect all material received for shipping damage. Confirm that your shipment includes all material and options ordered. If materials are missing or damaged, the carrier that made the delivery must be notified within 15 days of delivery in accordance with Interstate Commerce regulations in order to file a valid claim with the carrier. Any damaged material including all containers and packing should be held for carrier inspection. Contact our Customer Service Department, 6450 Dry Creek Parkway, Longmont, Colorado USA (telephone ) if your shipment is not correct for reasons other than shipping damage. Inspect all material received for shipping damage. Confirm that your shipment includes all material and options ordered. If items are missing or damaged the carrier making delivery to the customs broker must be notified within 15 days of delivery. If an airfreight forwarder handles the shipment and their agent delivers the shipment to customs the claim must be filed with the airfreight forwarder. If an airfreight forwarder delivers the shipment to a specific airline and the airline delivers the shipment to customs the claim must be filed with the airline, not the freight forwarder. Any damaged material, including all containers and packaging, should be held for carrier inspection. Contact our Customer Service Department, 6450 Dry Creek Parkway, Longmont, Colorado 80503, USA (telephone ) if your shipment is not correct for reasons other than shipping damage. 12 Mini-Convectron Module with Differential Output Amplifier

13 Safety and Introduction 1.8 Specifications Pressure Measurement Measurement Range for Air or N 2 1 mtorr to 760 Torr Measurements will change with different gases and mixtures. Do not use the module with flammable or explosive gases. The module is factory calibrated for use with Air or N 2. It measures the pressure of air correctly within the specified accuracy of the instrument. If the module will measure the pressure of a gas other than Air or N 2, you must calibrate the Mini-Convectron Module for the process gas. See Use with Gases other than N 2 and Air in the Calibration Chapter. Temperature Limits Operating Temperature Non-operating Temperature Gauge Tube Temperature Compensation Range Bakeout Temperature Range +4 to +50 C (+32 to +104 F) ambient, non-condensing 40 to +70 C ( 40 to +158 F) +15 to +50 C +85 C maximum with electronics attached +150 C maximum with electronics removed Power Requirements and Electrical Connections Power Requirement I/O Connector 11.0 to 16.0 Vdc, 0.12 A Must be protected against reversals, transients, or over-voltages. 9-pin D type Mini-Convectron Gauge Sensing Wire Filament Internal Volume Materials Exposed to Vacuum Gold-plated tungsten (standard) or solid platinum (optional) 40 cc (2.5 cu in) 304 stainless steel, gold, borosilicate glass, kovar, alumina, NiFe alloy, polyimide Analog Interface Differential Output Voltage Vdc to Vdc nonlinear corresponding to 0 to 760 Torr for N 2 Mini-Convectron Module with Differential Output Amplifier 13

14 Notes: 14 Mini-Convectron Module with Differential Output Amplifier

15 Chapter 2 Installation 2.1 Important Precautions for Mini-Convectron Installation The following precautions in the use and installation of the Mini-Convectron must be observed. It is recommended that the Mini-Convectron be installed with the port oriented vertically downward to ensure that no system condensates or other liquids collect in the gauge tube. The gauge tube axis must be horizontal if it is to be used at pressures above 1 Torr. Although the gauge tube will read correctly below 1 Torr when mounted in any position, erroneous readings will result at pressures above 1 Torr if the tube axis is not horizontal. Do not use a compression mount (quick connect) for attaching the Mini-Convectron to the system in applications resulting in positive pressures in the gauge tube. Positive pressures might blow the tube out of a compression fitting and damage equipment and injure personnel. Pipe thread or flange mounting systems should be used for positive pressure applications. In any case, the absolute pressure in the Convectron gauge tube should not exceed 1000 Torr. Do not mount the Mini-Convectron so that deposition of process vapors, upon the internal surfaces of the gauge tube, may occur through line-of-sight access to the interior of the gauge tube. Do not install the Mini-Convectron where high amplitudes of vibration are present. Excessive vibration will cause forced convection at high pressure giving erroneous readings. Do not install the gauge tubes where they will be subject to corrosive gases such as mercury vapor or fluorine which will attack the gold plated sensor. For greatest accuracy and repeatability the Mini-Convectron Module should be located in a stable room temperature environment. All connections to the Mini-Convectron Module are to be made with shielded cable. The shield or shields are to be connected to the connector shell. Mini-Convectron Module with Differential Output Amplifier 15

16 Chapter Mounting Location and Orientation Cleanliness pays. Keep the port cover in place until just before installation. For proper operation above about 1 Torr, install Mini-Convectron Modules with the gauge axis horizontal (see Figure 2-1). Although the gauge will read correctly below 1 Torr when mounted in any position, erroneous readings will result at pressures above 1 Torr if the gauge axis is not horizontal. Vibration causes convection cooling of the sensor and will result in high pressure readings. Mount Mini-Convectron Modules where they will not vibrate excessively. Orient the gauge to prevent condensation of process vapors on the internal surfaces through line-of-sight access to its interior. If vapor condensation is likely, orient the port downward to help liquids drain out. Figure 2-1 Mini-Convectron Module Installation 16 Mini-Convectron Module with Differential Output Amplifier

17 Installation Location Environment 2.3 Grounding Where you mount the Mini-Convectron Module is critical to obtaining reliable pressure measurements. Long tubing or other constrictions can cause large errors in pressure readings. If you mount the gauge near the pump, the pressure in the gauge may be considerably lower than in the rest of the system. If you place the gauge near a gas inlet or other source of contamination, the pressure in the gauge may be much higher than in the rest of the system. To minimize temperature effects, locate pressure gauges away from internal and external heat sources, in an area where the ambient temperature is reasonably constant. When high voltage is present, all exposed conductors of a vacuum must be maintained at earth ground. Under certain conditions, dangerously high voltage can be conducted through a gas directly to an ungrounded conductor almost as effectively as through a copper wire. The ability of an electric current to flow through a gas under certain circumstances poses a serious risk. Do not touch the exposed pins on any gauge installed on a vacuum system when high voltage is present. The Convectron Gauge envelope may not be reliably grounded through its vacuum connection. For safety, you must either add a separate ground wire, or shield the envelope to prevent human contact. Ground the gauge envelope by using a metal hose clamp on the gauge connected by a #12 AWG (minimum size) copper wire to the grounded vacuum chamber. Figure 2-2 Grounding the Mini-Convectron Gauge #12 AWG copper wire Mini-Convectron Module with Differential Output Amplifier 17

18 Chapter Dimensions Figure 2-3 Mini-Convectron Module Physical Dimensions 2.5 I/O Connector Wiring The 9-pin D type connector has the pin assignments shown below. Figure 2-4 Power and I/O Connector 18 Mini-Convectron Module with Differential Output Amplifier

19 Chapter 3 Operation 3.1 Theory of Operation The module measures gas pressures from 1 mtorr to 760 Torr. Vacuum chamber pressure is measured by a Convectron convection-enhanced Pirani heat-loss gauge. The Convectron gauge operates like a standard Pirani gauge, which employs the principle of a Wheatstone bridge to convert pressure to voltage, but uses convection cooling to enable accurate pressure measurement, when properly calibrated, from 1 mtorr to 760 Torr. The sensing wire is an ultra-fine strand of gold-plated tungsten or solid platinum. The heated sensing wire loses more heat as the ambient gas pressure increases. The more molecules contact the sensing wire, the more power is required to keep the sensing wire at a constant temperature. So, as pressure increases, the voltage across the Wheatstone bridge also increases. The Convectron gauge has a temperature compensator, which causes bridge voltage to remain unaffected by changes in ambient temperature. Figure 3-1 is a diagram of the module controller. The Convectron gauge sensing wire is designated R 1 in the Wheatstone bridge circuit. The temperature compensator is designated R 2. At bridge null, the following equation applies: R 1 = R 2 + R R 4 Figure 3-1 Wheatstone Bridge Diagram Bridge voltage is a non-linear function of pressure. This relationship is illustrated in Figure 3-1. If the ambient temperature does not change, R 1 remains constant. Mini-Convectron Module with Differential Output Amplifier 19

20 Chapter 3 As vacuum chamber pressure decreases, the number of molecules in the vacuum chamber and the resulting heat loss from the sensing wire also decrease. Temperature and R 1 resistance therefore increase. The increased resistance through R 1 causes the bridge to become unbalanced and a voltage to develop across the null terminals. The bridge controller senses the null voltage and decreases the voltage across the bridge until the null voltage again equals zero. When the bridge voltage decreases, the power dissipation in the sensing wire decreases, causing R 1 resistance to decrease to its previous value. A pressure increase causes an opposing series of occurrences, during which the bridge controller increases the bridge voltage to maintain a zero null voltage. 3.2 Front Panel Table 3-1 Front Panel Features Front panel feature P > 100 mtorr Indicator Function A red light emitting diode is used as a rough pressure indicator. The LED will be OFF below 100 millitorr and gradually turn ON as pressure increases. 3.3 Differential Analog Output Figures 3-2 and 3-3 illustrate the differential analog output voltage for N 2 /Air. The output is Vdc at vacuum, and Vdc at 760 Torr for N 2 /Air. If the output drops to ~0.20 Vdc, there is likely an open sensor in the gauge. If it drops to 0.0 Vdc, the input power (11 to 16 Vdc) has been interrupted. 20 Mini-Convectron Module with Differential Output Amplifier

21 Operation Figure 3-2 Differential Output Voltage vs. Pressure Mini-Convectron Module with Differential Output Amplifier 21

22 Chapter 3 Figure 3-3 Differential Output Voltage vs. Pressure 22 Mini-Convectron Module with Differential Output Amplifier

23 Operation 3.4 Use with Gases other than N 2 and Air Each Mini-Convectron gauge tube is individually calibrated for N 2 and temperature compensated prior to leaving the factory. It is important to understand that the indicated pressure on a Mini-Convectron gauge depends on the type of gas in the tube, and on the orientation of the tube axis as well as on the gas pressure in the tube. Mini-Convectron gauges are supplied calibrated for N 2 within the accuracy of the instrument. With certain safety precautions, the Mini-Convectron gauge may be used to measure pressure of other gases. Mini-Convectron gauge tubes are thermal conductivity gauges of the Pirani type. These gauges transduce gas pressure by measuring the heat loss from a heated sensor wire maintained at constant temperature. For gases other than N 2 and air the heat loss is different at any given true pressure and thus the indicated reading will be different. Figures 3-4 through 3-9 show the true pressure vs. indicated pressure for eleven commonly used gases. The following list will help to locate the proper graph: Table 3-2 Pressure vs. Indicated N 2 Pressure Curve Figure Pressure range and units Gases Figure to 10 1 Torr All Figure to 1000 Torr Ar, CO 2, CH 4, Freon 12, He Figure to 1000 Torr D 2, Freon 22, Kr, Ne, O 2 Figure to 10 1 mbar (Pascal) All Figure to 1000 mbar (Pascal) Ar, CO 2, CH 4, Freon 12, He Figure to 1000 mbar (Pascal) D 2, Freon 22, Kr, Ne, O 2 A useful interpretation of these curves is, for example, that at a true pressure of 2 x 10 2 Torr of CH 4 the heat loss from the sensor is the same as at a pressure of 3 x 10 2 Torr of N 2 (see Figure 3-4). The curves at higher pressure vary widely from gas to gas because the thermal losses at higher pressures are greatly different for different gases. The Mini-Convectron gauge tube uses convection cooling to provide resolution superior to any other thermal conductivity gauge near atmospheric pressure of N 2 and air. Because convection effects are geometry dependent, the true pressure vs indicated pressure curves for the Mini-Convectron gauge tube are likely to be much different from curves for heat loss tubes made by others. Therefore, it is not safe to attempt to use calibration curves supplied by other manufacturers for their gauges with the Convectron gauge, nor is it safe to use curves for the Convectron gauge with gauges supplied by other manufacturers. Mini-Convectron Module with Differential Output Amplifier 23

24 Chapter 3 If you must measure the pressure of gases other than N 2 or air, use Figures 3-4 through 3-9 to determine the maximum safe indicated pressure for the other gas as explained below. Example 1: Maximum safe indicated pressure Assume a certain system will withstand an internal pressure of 2000 Torr or 38.7 psia. For safety, limit the maximum internal pressure to 760 Torr during backfilling. Assume you want to measure the pressure of argon. On Figure 3-5 locate 760 Torr on the left hand scale, travel to the right to the intersection with the argon (Ar) curve and then down to an indicated pressure of 24 Torr (N 2 equivalent). Thus in this hypothetical situation the maximum safe indicated pressure for argon is 24 Torr. For safety, place a warning label on the instrument which under the assumed conditions would read "DO NOT EXCEED 24 TORR FOR ARGON." Example 2: Indicated to true pressure conversion Assume you want to determine the true pressure of argon in a system when the Convectron is indicating 10 Torr. On Figure 3-5, read up from 10 Torr (N 2 equivalent) indicated pressure to the argon curve and then horizontally to the left to a true pressure of 250 Torr. Thus 250 Torr argon pressure produces an indication of 10 Torr (N 2 equivalent). Example 3: True to indicated pressure conversion Assume you want to set a process control setpoint at a true pressure of 20 Torr of C0 2. On Figure 3-5, locate 20 Torr on the true pressure scale, travel horizontally to the right to the C0 2 curve and then down to an indicated pressure of 6 Torr (N 2 equivalent). Thus the correct process control setting for 20 Torr of C0 2 is 6 Torr (N 2 equivalent). Example 4: True to indicated pressure conversion Assume you want to obtain a helium pressure of 100 Torr in the system. On Figure 3-6, locate 100 Torr on the left hand scale, travel horizontally to the right to attempt to intersect the He curve. Because the intersection is off scale it is apparent that this true pressure measurement requirement for helium exceeds the capability of the instrument. NOTES: For gases other than those listed, the user must provide accurate conversion data for safe operation. The Mini-Convectron gauge is not intended for use above 1000 Torr true pressure. 1 mbar = 100 pascal, so the mbar charts may be used for pascal units by multiplying the values on the axes by Mini-Convectron Module with Differential Output Amplifier

25 Operation Figure 3-4 True Pressure vs Indicated Pressure for Commonly used Gases, 10 4 to 10 1 Torr Mini-Convectron Module with Differential Output Amplifier 25

26 Chapter 3 Figure 3-5 True Pressure vs Indicated Pressure for Commonly used Gases, 10 4 to 10 1 Torr 26 Mini-Convectron Module with Differential Output Amplifier

27 Operation Figure 3-6 True Pressure vs Indicated Pressure for Commonly used Gases, 10 4 to 10 1 Torr Mini-Convectron Module with Differential Output Amplifier 27

28 Chapter 3 Figure 3-7 True Pressure vs Indicated Pressure for Commonly used Gases, 10 4 to 10 1 mbar 28 Mini-Convectron Module with Differential Output Amplifier

29 Operation Figure 3-8 True Pressure vs Indicated Pressure for Commonly used Gases, 10 1 to 1000 mbar Mini-Convectron Module with Differential Output Amplifier 29

30 Chapter 3 Figure 3-9 True Pressure vs Indicated Pressure for Commonly used Gases, 10 1 to 1000 mbar 30 Mini-Convectron Module with Differential Output Amplifier

31 Chapter 4 Service/Maintenance 4.1 General Information It is recommended that only qualified technical personnel attempt repairs. If difficulties are encountered during use of your Mini-Convectron, the following list of symptoms and possible causes, along with the schematics, can prove useful in quickly getting back into operation. If the prescribed remedies do not correct the troubles, or if additional assistance or special parts are required, contact the Technical Service Department, Granville-Phillips, 6450 Dry Creek Parkway, Longmont, Colorado, Telephone: Repairs properly made with equivalent electronic parts and rosin core solder, which do not damage other portions of the unit, do not represent a violation of the warranty. Check Table 4-1 for the observed symptoms. This listing of symptoms and possible causes is not complete, but should be sufficient to solve most problems. All possible causes of failure should be thoroughly explored before attempting any repair. Since the Mini-Convectron contains static-sensitive electronic parts, the following precautions must be followed when troubleshooting: 1. Use a grounded, conductive work surface. 2. Use static dissipative envelopes to store or ship printed circuit boards. 3. Do not handle the printed circuit board more than absolutely necessary, and only when wearing a ground strap. 4. Do not use an ohmmeter for troubleshooting the electronics. Rely on voltage measurements. 5. Use grounded-type soldering irons only. 4.2 Mini-Convectron Disassembly For some of the troubleshooting procedures it will be required that the printed circuit board and gauge tube be removed from the enclosure. Proceed as follows to access the internal electronics and the gauge tube. 1. Disconnect the cable(s) on the side of the Mini-Convectron Module. 2. Remove the two screws on the front panel and remove the panel. 3. Slide the plastic case rearward to remove it from the gauge tube and electronics. Note that the PC Board guides are moulded into the plastic case. 4. Unplug the PC board assembly from the gauge tube. 5. For assembly, reverse this procedure. Make sure the PC boards are in the slots of the plastic case. Mini-Convectron Module with Differential Output Amplifier 31

32 Chapter Troubleshooting Table 4-1 Symptom General Symptoms/Possible Causes Possible Causes No power indication Bridge analog output voltage reads less than Vdc or greater than +10 Vdc No input power. Verify that there is +11 Vdc to +16 Vdc between pins 4 and 9 of the I/O connector on the Mini-Convectron Module. See Figure 2-4 on page 18. Gauge tube failure. Test for gauge tube failure. Measure the resistance between the following terminals with the gauge tube at atmospheric pressure and an ohmmeter which cannot apply more than 10 ma. See Mini-Convectron Disassembly on page-31for disassembly procedures. Pins 1 to 2: 18 to 23 ohms Pins 2 to 3: 50 to 60 ohms Pins 1 to 5: 180 to 185 ohms If the resistance from pins 1 to 2 reads about 800 ohms, the sensor wire in the gauge is broken. Replace the gauge tube. Note: If the resistance values shown here are correct, but you still think the gauge is not reading correctly, the gold plating on the sensor wire may be eroded and the gauge will have to be replaced. Bridge amplifier failure. This circuitry is located on the small PC board that the gauge tube plugs into. Check for input power to this board across the two outside fingers of the small board where it is soldered into the large board. Check that the bridge output voltage between the middle finger and the bottom finger is approximately 6 Vdc with the gauge tube at atmosphere. Readout indicating a pressure in the system is vastly different than that being observed by supporting gauges Gas composition on system is not what the user believes it to be. This can be caused by selective gas pumping, process in use, outgassing of product, etc. Determine gas composition and calibrate accordingly. The gauge tube is contaminated with material from the vacuum system. Clean the gauge tube. See Convectron Gauge Bakeout Instructions on page-33 and Cleaning a Convectron Gauge on page-33. If not effective, replace gauge tube. 32 Mini-Convectron Module with Differential Output Amplifier

33 Service/Maintenance 4.4 Convectron Gauge Bakeout Instructions 4.5 Cleaning a Convectron Gauge The Convectron gauge can be baked to 85 0 C with the electronics attached, but not operational. To bake the Convectron gauge to a higher temperature, up to C, the electronics must be removed. See Mini-Convectron Disassembly on page-31 for disassembly procedures. With the electronics removed, perform the bakeout up to C. Measure the temperature at the mounting flange of the Convectron gauge. After the system has cooled down, reassemble the electronics and connect the cable(s). Prior to cleaning, the gauge tube must be removed from the electronics as described on page 31. Cleaning solvents can damage electronic components or the enclosure. When the small sensor wire is contaminated with oil or other films, its emissivity or its diameter may be appreciably altered and a change of calibration will result. Cleaning with trichloroethylene, perchloroethylene, toluene, or acetone is possible but it must be done very carefully to not damage the sensor. The fumes from solvents such as trichloroethylene, perchloroethylene, toluene, and acetone can be dangerous to health if inhaled. Only use these solvents in well ventilated areas exhausted to the outdoors. Acetone and toluene are highly flammable and should not be used near an open flame or energized electrical equipment. 1. Hold the gauge with the main body horizontal and the port projecting upward at a 45 angle. 2. Slowly fill the port with solvent using a standard wash bottle with the spout inserted in the port to the point where it touches the screen. Let the solvent stand in the gauge for at least ten minutes. Do not shake the gauge. Shaking the gauge with liquid inside can damage the sensor wire. 3. To drain the gauge, position it horizontally with the port facing downward. 4. Allow the gauge to dry overnight with the port vertically downward and uncapped. Before re-installing the gauge on the system, be certain no solvent odor remains. 5. If the gold plating on sensor has been attacked by a gas such as fluorine or mercury vapor, changing its emissivity and/or resistance, replace the gauge tube. Cleaning cannot solve this problem. Mini-Convectron Module with Differential Output Amplifier 33

34 Chapter Returning a Mini-Convectron Module for Service If the product requires service, contact the MKS, Granville-Phillips Division Customer Service Department at or for troubleshooting help over the phone. If the product must be returned to the factory for service, request a Return Material Authorization (RMA) from Granville-Phillips. Do not return products without first obtaining an RMA. In some cases a hazardous materials document may be required. The MKS/Granville-Phillips Customer Service Representative will advise you if the hazardous materials document is required. When returning a products to Granville-Phillips, be sure to package the products to prevent shipping damage. Circuit boards and modules separated from the gauge assembly must be handled using proper anti-static protection methods and must be packaged in anti-static packaging. Granville-Phillips will supply return packaging materials at no charge upon request. Shipping damage on returned products as a result of inadequate packaging is the Buyer's responsibility. For Customer Service or Technical Support 24 hours per day, 7 days per week, every day of the year including holidays: Phone: or gp-csr@mksinst.com MKS, Granville-Phillips Division 6450 Dry Creek Parkway Longmont, CO USA Phone: or FAX: Mini-Convectron Module with Differential Output Amplifier

35 Index B Bakeout Instructions Convectron Gauge 33 C Caution statements 8 Cleaning a Convectron Gauge 33 Connector I/O 18 Power 18 Convectron Gauge Bakeout Instructions 33 Cleaning 33 Internal Volume 13 Sensing Wire Filament 13 D Differential Analog Output 20 Dimensions 18 E Environment for installation 17 Explosion / Implosion 9 F Figures module with two relays, no display 18 Front panel 20 Fumes from solvents 9 G Grounding 17 I I/O connector wiring 18 Indicated Pressure vs True Pressure 23 Installation environment 17 grounding 17 Important Precautions 15 location 17 Mounting orientation 16 L Lethal Voltages 11 Location for installation 17 M Mini-Convectron module Disassembly 31 Module Physical Dimensions 18 Power Supply 13 Temperature 13 P P > 100 mtorr indicator 20 Physical dimensions 18 Pressure Curves 23 Pressure Measurement 13 Pressure Measurement Range 13 R Reading and Following Instructions 8 S Safety 7 instructions 7 Service Contact 34 Return for Repair 34 Service Guidelines 11 Specifications 13 Convectron Gauge Internal Volume 13 Convectron Gauge Sensing Wire 13 I/O connector 13 Power Supply 13 Pressure Measurement 13 Temperature 13 System Grounding 11 T Temperature Non-operating 13 Operating 13 True Pressure vs Indicated Pressure 23 Mini-Convectron Module with Differential Output Amplifier 35

36 Index W Warning statements 8 Wheatstone Bridge Diagram 19 Wiring I/O Connector Specifications Mini-Convectron Module with Differential Output Amplifier

37

38 Series 275 Granville-Phillips Mini-Convectron Module with Differential Output Amplifier For Customer Service or Technical Support 24 hours per day, 7 days per week, every day of the year including holidays: Phone: or MKS, Granville-Phillips Division 6450 Dry Creek Parkway Longmont, CO USA Phone: or FAX: gp-csr@mksinst.com Corporate Office MKS Instruments, Inc. 2 Tech Drive, Suite 201 Andover, MA USA Phone: Instruction Manual Instruction manual part number Revision D - September 2014

Series 275 Mini-Convectron Vacuum Gauge Module with Linear Analog Output Instruction Manual

Series 275 Mini-Convectron Vacuum Gauge Module with Linear Analog Output Instruction Manual Series 275 Mini-Convectron Vacuum Gauge Module with Linear Analog Output Instruction Manual Instruction Manual Instruction manual part number 275539 Revision H - July 2017 Series 275 Mini-Convectron Module

More information

Series 342 Granville-Phillips Series 342 & 343 Ion Gauge Controllers

Series 342 Granville-Phillips Series 342 & 343 Ion Gauge Controllers Series 342 Granville-Phillips Series 342 & 343 Ion Gauge Controllers Instruction Manual Instruction manual part number 342026 Revision D - October 2014 Instruction manual part number 342026 Series 342

More information

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION

More information

Series 275 Granville-Phillips Mini-Convectron Module with RS-485 Interface

Series 275 Granville-Phillips Mini-Convectron Module with RS-485 Interface Series 275 Granville-Phillips Mini-Convectron Module with RS-485 Interface Instruction Manual Instruction manual part number 275955 Revision E - September 2015 Series 275 Granville-Phillips Mini-Convectron

More information

Series 245. Granville-Phillips Series 245 Pressure/Flow Control Valve Assembly. Instruction Manual

Series 245. Granville-Phillips Series 245 Pressure/Flow Control Valve Assembly. Instruction Manual Series 245 Granville-Phillips Series 245 Pressure/Flow Control Valve Assembly Instruction Manual Instruction manual part number 245001 Revision B - January 2016 Tube Bend Styles NOTE: The gear box cover

More information

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller w w w. m k s i n s t. c o m Pressure & Vacuum Measurement Solutions Series 370 Stabil-Ion Vacuum gauge and Controller Features & Benefits All-metal, rack-mount controller for Stabil-Ion and Convectron

More information

Introductory Lab: Vacuum Methods

Introductory Lab: Vacuum Methods Introductory Lab: Vacuum Methods Experiments in Modern Physics (P451) In this lab you will become familiar with the various components of the lab vacuum system. There are many books on this topic one of

More information

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson A Journal of Practical and Useful Vacuum Technology From By Phil Danielson Thermal Conductivity Gauges Thermal conductivity pressure gauges are extremely common in vacuum technology, but an understanding

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

Vacuum Gauge with Integrated Controller & Display. 275i Series Convection Vacuum Gauge Module. User Manual (Unit of measure in Torr / mtorr)

Vacuum Gauge with Integrated Controller & Display. 275i Series Convection Vacuum Gauge Module. User Manual (Unit of measure in Torr / mtorr) Vacuum Gauge with Integrated Controller & Display 275i Series Convection Vacuum Gauge Module User Manual (Unit of measure in Torr / mtorr) Kurt J. Lesker Company 1925 Rt. 51 Jefferson Hills, PA 15025 USA

More information

Vacuum Gauge with Integrated Controller & Display. 275i Series Convection Vacuum Gauge Module. User Manual

Vacuum Gauge with Integrated Controller & Display. 275i Series Convection Vacuum Gauge Module. User Manual Vacuum Gauge with Integrated Controller & Display 275i Series Convection Vacuum Gauge Module User Manual Kurt J. Lesker Company 1925 Rt. 51 Jefferson Hills, PA 15025 USA Phone: +1-412-387-9200 Fax: +1-412-384-2745

More information

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer July 2011 OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer WARNING! Before operating this product, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Contact

More information

275 series Convection Vacuum Gauge

275 series Convection Vacuum Gauge 275 series Convection Vacuum Gauge User Manual Kurt J. Lesker Company 1925 Rt. 51 Jefferson Hills, PA 15025 USA Phone: +1-412-387-9200 Fax: +1-412-384-2745 E-mail: gauging@lesker.com www.lesker.com p/n

More information

User s Guide Temperature Sensor Converter TSC-599

User s Guide Temperature Sensor Converter TSC-599 User s Guide Temperature Sensor Converter TSC-599 ILX Lightwave Corporation 31950 Frontage Road Bozeman, MT, U.S.A. 59715 U.S. & Canada: 1-800-459-9459 International Inquiries: 406-556-2481 Fax 406-586-9405

More information

InstruTech. CVM211 Convection Vacuum Gauge Module The Stinger. User Manual (Unit of measure in bar / mbar)

InstruTech. CVM211 Convection Vacuum Gauge Module The Stinger. User Manual (Unit of measure in bar / mbar) InstruTech CVM211 Convection Vacuum Gauge Module The Stinger User Manual (Unit of measure in bar / mbar) InstruTech 1475 S. Fordham St. Longmont, CO 80503 USA Phone: +1-303-651-0551 Fax: +1-303-678-1754

More information

WIKA INSTRUMENT CORPORATION

WIKA INSTRUMENT CORPORATION WIKA INSTRUMENT CORPORATION Instruction Manual DIFFERENTIAL PRESSURE GAUGE Series 1500 Series 1000 Series 300 WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043 1-888-945-2872 http://www.wika.com

More information

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller

Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller All-metal, rack-mount controller for Stabil-Ion and Convectron vacuum gauges is noise-immune and CE compliant Accurate vacuum pressure measurement

More information

The Experts in Vacuum Solutions

The Experts in Vacuum Solutions By Woodrow Farrow - Reprinted with permission from Specialty Gas Report Vacuum: a space that is relatively empty of matter, especially when that void has been created through artificial means. The earth

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

375 Series Panel Mount / Bench Top Vacuum Gauge Controller

375 Series Panel Mount / Bench Top Vacuum Gauge Controller 375 Series Panel Mount / Bench Top Vacuum Gauge Controller User Manual Kurt J. Lesker Company 1925 Rt. 51 Jefferson Hills, PA 15025 USA Phone: +1-412-387-9200 Fax: +1-412-384-2745 E-mail: gauging@lesker.com

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

INSTRUCTION MANUAL. Lesker Model KJL615TC-K Lesker Model KJL615TC-H. Digital Vacuum Gauge/Controller. KJL615TC K/H Ranges

INSTRUCTION MANUAL. Lesker Model KJL615TC-K Lesker Model KJL615TC-H. Digital Vacuum Gauge/Controller. KJL615TC K/H Ranges INSTRUCTION MANUAL Lesker Model KJL615TC-K Lesker Model KJL615TC-H Digital Vacuum Gauge/Controller KJL615TC K/H Ranges 1 to 1999 millitorr 1 to 1990 microbar 1 to 199.9 Pascal Standard Features Selectable

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230 Instruction Manual Digital Thermocouple Gauge Control Units Models DTC-531-115 & DTC-531-230 Models DTC-06M-115 & DTC-06M-230 Copyright 1998 by Duniway Stockroom Corp. 021315lh 1 of 7 Table of Contents

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 36-751 XenoGard 133 Xe Monitor Operators Manual March 2005 Manual No. 128011 Rev. 3 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks

More information

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1 Instruction Manual 742 5/1/2009 Eclipse Ratio Regulators ES Series Version 1 Copyright Copyright 1997 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation

More information

Series 203 Granville-Phillips Variable Leak Valve

Series 203 Granville-Phillips Variable Leak Valve Series 203 Granville-Phillips Variable Leak Valve Instruction Manual Instruction manual part number 203026 Revision B - November 2016 Series 203 Granville-Phillips Variable Leak Valve Customer Service

More information

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL TABLE OF CONTENTS PRODUCT OVERVIEW 2 I - USE AND CARE: 3 II - INSTALLATION: 5 III - GENERAL MAINTENANCE TIPS: 5 IV - APPENDIX: A-1 2-WIRE CURRENT LOOP

More information

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION BEST KNOWN METHODS Transpector XPR3 Gas Analysis System DESCRIPTION The Transpector XPR3 is a third-generation, quadrupole-based residual gas analyzer that operates at PVD process pressures and is the

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION Application Note Doc. G8108-001 Rev. A - 23-Jul-02 ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION For more information regarding Digiquartz products contact: Paroscientific,

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

Instruction Manual No. 742, 8/98

Instruction Manual No. 742, 8/98 Instruction Manual No. 742, 8/98 Eclipse Ratio Regulators ES Series COPYRIGHT Copyright I997 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication is protected by federal regulation

More information

SDX Submersible Depth Transmitter User Manual

SDX Submersible Depth Transmitter User Manual SDX Submersible Depth Transmitter User Manual July 2017 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.

More information

Vacuum Gauge Controller MGC User Manual

Vacuum Gauge Controller MGC User Manual Vacuum Gauge Controller MGC-3200 User Manual Kurt J. Lesker Company 1925 Rt. 51 Jefferson Hills, PA 15025 USA Phone: +1-412-387-9200 Fax: +1-412-384-2745 E-mail: gauging@lesker.com www.lesker.com p/n 002256-108

More information

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar Instruction Manual D356-10-880 Issue G Original CG16K Barometrically Compensated Capsule Dial Gauge Description CG16K Capsule Dial Gauge, 0 to 1040 mbar CG16K Capsule Dial Gauge, 0 to 125 mbar CG16K Capsule

More information

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS 2561762B REV. B 210 Printed in U.S.A. INSTALLATION AND SERVICE INSTRUCTIONS

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

SDX Submersible Depth Transmitter User Manual

SDX Submersible Depth Transmitter User Manual SDX Submersible Depth Transmitter User Manual October 2007 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

Victoreen B. Operators Manual. Image Intensifier Ion Chamber Victoreen 6000-530B Image Intensifier Ion Chamber Operators Manual March 2005 Manual No 6000-530B-1 Rev. 4 2004, 2005 Fluke Corporation, All rights reserved. All product names are trademarks of their respective

More information

InstruTech, Inc. Vacuum Gauge Controller B-RAX User Manual. InstruTech, Inc S. Fordham St. Longmont, CO USA

InstruTech, Inc. Vacuum Gauge Controller B-RAX User Manual. InstruTech, Inc S. Fordham St. Longmont, CO USA InstruTech, Inc. Vacuum Gauge Controller B-RAX 3100 User Manual InstruTech, Inc. 1475 S. Fordham St. Longmont, CO 80503 USA Phone: +1-303-651-0551 Fax: +1-303-678-1754 E-mail info@instrutechinc.com www.instrutechinc.com

More information

Electropneumatic Transducer (I/P) Installation, Operation and

Electropneumatic Transducer (I/P) Installation, Operation and Nitra NCP1 Series Electropneumatic Transducer (I/P) Installation, Operation and Maintenance Instructions Ordering Information Contents Part Number I/P Transducers Output Range Input psig bar Section Description

More information

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Table of Contents 1. Introduction 3 2. Instrument Setup 4 2.1 Instrument Checklist 4 2.2 Optional Accessories 4 2.3 Gas Concentration Ranges Available

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

InstruTech. CVM201 Convection Vacuum Gauge Module The Super Bee. User Manual. InstruTech 1475 S. Fordham St. Longmont, CO USA

InstruTech. CVM201 Convection Vacuum Gauge Module The Super Bee. User Manual. InstruTech 1475 S. Fordham St. Longmont, CO USA InstruTech CVM201 Convection Vacuum Gauge Module The Super Bee User Manual InstruTech 1475 S. Fordham St. Longmont, CO 80503 USA Phone: +1-303-651-0551 Fax: +1-303-678-1754 E-mail info@instrutechinc.com

More information

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement

More information

InstruTech. Cold Cathode Ionization Vacuum Gauge CCM500 Module The Hornet. User Manual. InstruTech 1475 S. Fordham St. Longmont, CO USA

InstruTech. Cold Cathode Ionization Vacuum Gauge CCM500 Module The Hornet. User Manual. InstruTech 1475 S. Fordham St. Longmont, CO USA InstruTech Cold Cathode Ionization Vacuum Gauge CCM500 Module The Hornet User Manual InstruTech 1475 S. Fordham St. Longmont, CO 80503 USA Phone: +1-303-651-0551 Fax: +1-303-678-1754 E-mail info@instrutechinc.com

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1800-75 Respiration Test Chamber Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA

More information

Best Practice Guide, Servomex 2700

Best Practice Guide, Servomex 2700 For full installations details refer to the. Best Practice Guide, Servomex 2700 Mounting: General Guidelines: Servomex 2700 Control Units and air supplies (utilities units) should, ideally, be mounted

More information

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

Coriolis Mass Flow Meter

Coriolis Mass Flow Meter Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;

More information

HPS Series 947. Digital Convection Enhanced Pirani (CEP) Vacuum Sensor System OPERATION AND MAINTENANCE MANUAL

HPS Series 947. Digital Convection Enhanced Pirani (CEP) Vacuum Sensor System OPERATION AND MAINTENANCE MANUAL HPS Series 947 Digital Convection Enhanced Pirani (CEP) Vacuum Sensor System OPERATION AND MAINTENANCE MANUAL SensaVac Series 947 Digital Convection Enhanced Pirani (CEP) Vacuum Sensor System February

More information

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel TANK MANAGER FOR TWO TANKS OPERATING MANUAL 10/31/11 C-More T6C L color touch panel 1 TABLE OF CONTENTS GENERAL...3 INSTALLATION...4 STONE TEST PROCEDURE...7 OPERATIONAL SUMMARY...7 AUTO CARBONATION...10

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel: PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)

More information

KOBOLD KSM FLOWMETER. User Instructions

KOBOLD KSM FLOWMETER. User Instructions KOBOLD KSM FLOWMETER User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com KSM_manual_08-10 Table

More information

Model Series 62 Constant Differential Relay

Model Series 62 Constant Differential Relay Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant

More information

375 Series Panel Mount / Bench Top Vacuum Gauge Controller

375 Series Panel Mount / Bench Top Vacuum Gauge Controller 375 Series Panel Mount / Bench Top Vacuum Gauge Controller User Manual Kurt J. Lesker Company 1925 Rt. 51 Jefferson Hills, PA 15025 USA Phone: +1-412-387-9200 Fax: +1-412-384-2745 E-mail: gauging@lesker.com

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

The Principles of Vacuum Technology

The Principles of Vacuum Technology The Principles of Vacuum Technology Vacuum Terminology Vacuum units Vacuum regimes How to measure vacuum. Gauge designs. How to create vacuum Pump classifications and designs UHV compatibility considerations

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

Installation Instructions

Installation Instructions 48011HW NATURAL GAS TO PROPANE CONVERSION KIT 58HDX, 359AAV, PG9YAB, PG9YAA Installation Instructions SAFETY REQUIREMENTS Installing and servicing heating equipment can be hazardous due to gas and electrical

More information

Norrsken Family Booklet

Norrsken Family Booklet Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation

More information

AMT-Ex Dewpoint Transmitter

AMT-Ex Dewpoint Transmitter AMT-Ex Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

Pressure Measurement. Introduction. Engr325 Instrumentation. Dr Curtis Nelson 3/12/18

Pressure Measurement. Introduction. Engr325 Instrumentation. Dr Curtis Nelson 3/12/18 3/12/18 Pressure Measurement Engr325 Instrumentation Dr Curtis Nelson Introduction A cluster of 72 helium-filled balloons over Temecula, California in April of 2003. The helium balloons displace approximately

More information

DIGIVAC 22W Series INSTRUCTION MANUAL. Wide Range Linearized Vacuum Transmitter and Controller YOU MUST READ THIS MANUAL BEFORE USE

DIGIVAC 22W Series INSTRUCTION MANUAL. Wide Range Linearized Vacuum Transmitter and Controller YOU MUST READ THIS MANUAL BEFORE USE DIGIVAC 22W Series INSTRUCTION MANUAL Wide Range Linearized Vacuum Transmitter and Controller YOU MUST READ THIS MANUAL BEFORE USE The Digivac Company 105B Church Street Matawan, NJ 07747 Email: sales@digivac.com

More information

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS INTRODUCTION The Janis Research Company's Superconducting Magnet/Cryostat System is one of the most versatile tools available to the scientist

More information

The Broadest Gauging Line in the Industry

The Broadest Gauging Line in the Industry The Broadest Gauging Line in the Industry Vacuum Measurement Varian s broad line of vacuum gauge controllers and gauge tubes are the most reliable, accurate, and economical means of measuring, monitoring,

More information

InstruTech, Inc. Vacuum Gauge Controller B-RAX TM User Manual. InstruTech, Inc S. Fordham St. Longmont, CO USA

InstruTech, Inc. Vacuum Gauge Controller B-RAX TM User Manual. InstruTech, Inc S. Fordham St. Longmont, CO USA InstruTech, Inc. Vacuum Gauge Controller B-RAX TM 3200 User Manual InstruTech, Inc. 1475 S. Fordham St. Longmont, CO 80503 USA Phone: +1-303-651-0551 Fax: +1-303-678-1754 E-mail info@instrutechinc.com

More information

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1250 METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Total Organic Compounds N/A

More information

BGA244 Binary Gas Analyzer

BGA244 Binary Gas Analyzer Quick Start Guide Revision 1.0 Certification Warranty Service certifies that this product met its published specification at the time of shipment. This product is warranted against defects in materials

More information

SX150A. Features. Typical Applications. Description

SX150A. Features. Typical Applications. Description Datasheet -- Pressure Sensors: Measurement Type: Absolute; 0 psia to 150 psia, Unamplified, Representative photograph, actual product appearance may vary. Due to regional agency approval requirements,

More information

The Ins and Outs of I/P Transducers

The Ins and Outs of I/P Transducers The Ins and Outs of I/P Transducers By Mark B. Levine, ControlAir Inc. General description I/P transducers are versatile instruments that use an electrical control signal to proportionally regulate gas

More information

User Manual. Quantos Automated Dosing Liquid Module

User Manual. Quantos Automated Dosing Liquid Module User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if

More information

_ pressure transducers. User Manual

_ pressure transducers. User Manual _ pressure transducers User Manual summary introduction DescriPTION preliminary checks Installation taking measurements data management Troubleshooting maintenance Appendix 1 Page 4 Page 5 Page 6 Page

More information

T EK-SUB 4800C 19 mm Submersible Level Transmitter

T EK-SUB 4800C 19 mm Submersible Level Transmitter Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2

More information

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed

More information

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions VB-7323 Series 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions Application VB-7323 series three-way diverting valves control hot or chilled water in heating or air conditioning systems.

More information

Instruction Manual EMA 84 Digital Pressure Gauge

Instruction Manual EMA 84 Digital Pressure Gauge Instruction Manual EMA 84 Digital Pressure Gauge halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL. SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG

More information

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064 AIR HAMMERS MODEL NO: CAT138/CAT139 PART NO: 3120152 /3120153 OPERATING & MAINTENANCE INSTRUCTIONS GC064 INTRODUCTION Thank you for purchasing this CLARKE Air Hammer. Before attempting to use this product,

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information