Salt Spray Test Chamber Models:

Size: px
Start display at page:

Download "Salt Spray Test Chamber Models:"

Transcription

1 Salt Spray Test Chamber Models: S120/450/1000/1300/2000/2600IS Instruction Manual IS Issue - P Ascott Analytical Equipment Limited, 6-8 Gerard, Lichfield Road Industrial Estate, Tamworth, Staffs. B79 7UW Great Britain Telephone: +44 (0) Fax: +44 (0) info@ascott-analytical.com Website: 1

2 Contents Contents 2 Introduction - General Description of machine operation 5 Part 1 - Health & Safety Health and Safety Policy Transport and Lifting 11 Part 2 - Installation Operating Environment Positioning External Services Electrical Supply Compressed Air Supply De-ionised Water Supply Salt Solution Reservoir Condensate Drain Exhaust Vent to Atmosphere Air Saturator Drain Atomiser Set up 23 Part 3 - Operation Human Machine Interface (HMI) Screen Initial Power Up Contact Details Chamber Information Run Screen Run Screen Stopped / Running Starting/Stopping a test Test Mode Canopy Run Mode Chamber Temperature Display Air Saturator Temperature Display Hours Run Display Setup Mode 35 2

3 3.5.1 Time to stop Hours Run Reset Air Saturator (Moist air / Dry Air) Pump Speed(s) Chamber Temperature Set point Air Saturator Temperature Setpoint Alarm Status Control Emergency Stop Mains Isolator Air Pressure Gauge & Regulator Flow Meter(s) & Peristaltic Pump(s) Setting Up Procedure Determine the test parameters Set up chamber Set the Salt Fog Fallout Rate Shut down procedure: 49 Part 4 - Care & Maintenance Routine Maintenance Daily Checks Weekly Maintenance Three Monthly Maintenance After Use Unscheduled Maintenance Storage & Contamination Deionised Water Inlet Filter Clean or Unblock Salt Spray Atomiser Sample Daily Check Sheet Fault Finding Salt Spray Chamber Exploded Views S120is Control Compartment (Base Plate) S120is Front Ascott Chamber S120is Rear Ascott Chamber S450is Control Compartment (Base Plate) S450is Front Ascott Chamber S450is Services Panels (Rear External) S450is Service Panels (Rear Internal) S1000is Control Compartment (Base Plate) S1000is Front Ascott Chamber S1000is Services Panels (Rear External) S1000is Services Panels (Rear Internal) 71 3

4 4.5.3 S1000is Rear Ascott Chamber S2000is Control Compartment (Base Plate) S2000is Front Ascott Chamber S2000is Services Panel (Rear External) S2000is Services Panels (Rear Internal) S2000is Rear Ascott Chamber Salt Spray Chamber Exploded Views S120is Air Saturator S2000is and S2600is Air Saturators (Glass fabrication) S120is, S450is, S1000is and S1300is SS200is and SS2600is 89 5 Optional Accessories Manual (If Ordered) 93 4

5 Introduction - General Description of machine operation The Salt Spray test (also known as a salt fog or salt mist) has been the benchmark corrosion test in many industries for decades The Ascott Salt Spray chambers (is) meet the requirements of basic, continuous salt spray tests conducted at a single temperature only, such as ASTM B117 and similar international test standards, and may be used with ph neutral salt solutions (NSS) or those acidified by the addition of Acetic Acid (ASS) or Cupric Acid (CASS). 5

6 Part 1 - Health & Safety 1.1 Health and Safety Policy The manufacturer is required to ensure, for reasons of Health and Safety at Work that, as far as is reasonably practicable, the articles which we design, produce and supply are as safe as possible and of minimal risk to health. We are required to provide information on the safety and handling precautions to be observed when installing, operating and maintaining our product. Such advice is contained in this manual. We should also like to point out, however that you as users have an important responsibility in the provision and maintenance of safe working practices and conditions. Accordingly we draw to your attention the following matters: i. This apparatus should only be used as intended and within its design parameters by suitably qualified and trained personnel who have read and understood the relevant sections of this manual. ii This manual should be readily available to such personnel at all times. iii In addition to that which is written in the manual, normal common-sense safety precautions must be taken at all times to avoid the possibility of accidents. ivinstallation, maintenance and connection to electrical supplies should only be carried out by suitably trained personnel. We would recommend that users produce their own risk assessment for the entire testing process for which this apparatus will be used. The normal operation noise levels for the chamber are shown below and if they exceed these parameters then there is a problem with the chamber. Please obtain advise from your local agent / distributor or Ascott themselves to ascertain problem. Some accessories may deviate from these levels. Warning! - connecting an Ascott chamber to poor quality external service utilities (ie; water and compressed air) and/or a failure to maintain Ascott products regularly in accordance with Ascott recommended maintenance procedures, could lead to a catastrophic and potentially dangerous failure of the product safety systems. 6

7 Declared Dual-Number Noise Declaration Manufacturer Type Ascott Analytical Equipment Ltd Cyclic Corrosion Test Chambers (CC1000iP) Declared Dual Number Noise Emission Values according to EN ISO 4871 A-Weighted Emission Sound Pressure Level at the Work Station Measured value Lpa in decibels Uncertainty Kpa in decibels 1.50 A-Weighted Emission Sound Power Level Measured Value Lwa in Decibels Uncertainty Kwa in decibels 1.50 The determination, declaration and verification of airborne noise emission have been carried out in accordance with EN as required within clause (Noise reduction at source at the design stage) of EN :2005+A1:2010 Values determined according to the noise test code EN using the basic standards EN ISO (Grade 2) and EN ISO

8 Training is available if required. Please contact Ascott or your Agent / Distributor for more details. No specific PPE is required during standard operation of the chamber as the chamber is designed to purge the atmosphere before opening the canopy to the chamber working area. Some accessories may require PPE to be worn. All accessories that utilise sub-zero temperatures will require gloves to be worn when handling anything inside the chamber. Accessory ACC46 SO2 testing facility must follow the instructions for the accessory as the atmosphere and bi products can be extremely hazardous. Under no circumstances should anyone be inside the chamber during operation or exposed to the corrosive atmosphere of the chamber. All leaks must be reported and repaired. Chamber must be isolated immediately if any atmosphere or water leaks are detected. No structural changes or fitting of customers own tools / accessories without first contacting Ascott or its associates. In the event of a breakdown consult Ascott or its associates immediately as further damage to the chamber and / or personnel may occur. Ascott chambers will have the following safety labels attached to the side panel work. Warning people of potential Electric shock. Warning people of hot water, confined space and sharp edges. 8

9 The control panel also has two labels to identify the Air Pressure Gauge for the chamber and the regulator for the air Supply. Denotes Pressure Gauge Denotes Pressure Regulator 9

10 Inside the control compartment the earthing point of the chamber is clearly identified with the following symbol 10

11 1.2 Transport and Lifting Lifting of the chamber should only be done with a fork truck and lifted using the designated lifting points at the rear of the chamber. The lifting points are identified with the following logos. When transporting the chamber ensure it is locked and strapped into position preferably chocked up off the castors using the chassis frame. No loads are to be put on the top. Drains must be emptied before loading. 11

12 Part 2 - Installation CAUTION THE EQUIPMENT SHOULD ONLY BE INSTALLED BY SUITABLY QUALIFIED PERSONNEL. DAMAGE CAUSED DUE TO INCORRECT INSTALLATION WILL NOT BE COVERED BY THE WARRANTY. 2.1 Operating Environment Ascott chambers are designed to minimise the risk of an uncontrolled escape of the corrosive conditions they generate. However, this risk remains and if there is an uncontrolled escape this is likely to contaminate the local surroundings and may in some cases be hazardous to human health. When choosing a location for the installation of an Ascott chamber, a risk assessment should be undertaken to identify the most appropriate location and minimise the risks arising. This equipment is designed for internal use only, in an environment controlled to within the following limits:- Ambient Temperature:+18 to +23 C (no icing) Note: The minimum operating temperature of the chamber will depend directly upon the actual ambient temperature of the environment in which it is located. Ambient Humidity:45 to 85% RH (no condensation) 12

13 2.2 Positioning Move the Salt Spray Test Chamber into position as shown: Chamber The rear castors can be locked when the chamber has been positioned. 13

14 2.3 External Services Note:All hoses and pipes up to 3 metres (10ft) in length, and the power cable are supplied with the chamber. Electricity single phase with neutral & earth. Compressed air 12.5 mm (½ ) bore hose Salt Water 3 mm (1/8 ) bore hose (to separate salt solution reservoir) Water 12.5 mm (½ ) bore hose 14

15 2.3.1 Electrical Supply We recommend this equipment is connected to an electrical supply protected by a residual current device (earth leakage circuit breaker). Before connecting this equipment to an electrical supply, check the information given on the equipment rating plate and ensure that: Your supply voltage is of the correct frequency. Your supply voltage is the correct type (three phase or Single phase depending on model) Your supply voltage is within the stated range. The current rating is within the capacity of your supply outlet. Your plug or outlet circuit is suitably fused. WARNING: THIS APPARATUS MUST BE EARTHED 15

16 A rotary electrical isolator switch is mounted in a prominent position on the chamber. This isolates the chamber from the incoming electrical supply (live and neutral) when the switch is rotated to the '0' position, and can be padlocked in this position if required. The electrical supply is connected when this switch is rotated to the '1' position Compressed Air Supply Note:The compressed air supply must be clean, dry (a cohesive dryer of grade 2 which will give 3 microns cleanliness) and oil free. It must have a minimum pressure of 4.0 bar (57 psi) and a maximum pressure of 6.0 bar (87 psi). Between these pressures, the flow rate should be at least 75 litres per minute (2.6 cubic feet per minute) equating to a free flow at atmospheric pressure of approximately 102 standard litres per minute (3.6 standard cubic feet per minute). Connect the 12.5 mm bore air hose supplied, between the air inlet at the rear of the chamber and the compressed air supply. (See above) De-ionised Water Supply Note: The de-ionised water supply must have a minimum pressure of 0.5 bar (7PSI) and a maximum of 5 bar (72PSI). Connect the 12.5 mm bore water hose supplied, between the two water inlet hose connections at the rear of the chamber and the de-ionised water supply. (See above). 16

17 2.3.4 Salt Solution Reservoir Position the Salt Solution Reservoir to the left of the chamber. Salt Solution Reservoir The side wall has a hole to allow the salt solution hose to pass through. Salt solution inlet hose 120L 17

18 For 120 Litre chambers, an external reservoir can be used in place of the internal reservoir Locate existing salt solution hose at back of cabinet Disconnect bottom of hose from grey fitting and salvage compression fittings from end of hose. Use salvaged compression fittings to attach a new length of salt solution hose (internal diameter 4mm external diameter 6mm) of sufficient length (3m) to reach the auxiliary salt solution reservoir, and attach primary filter unit. Drop primary filter unit into auxiliary salt solution reservoir so that it rests at the bottom. The chamber is now ready for use. 18

19 Feed the end of the 6 mm salt solution hose that is fitted with a filter, into the Salt Solution Reservoir ensuring that the filter unit lies at the bottom of the reservoir Condensate Drain Drain 22 mm (7/8 ) diameter pipe Connect the 22 mm diameter push-fit pipe to the rear of the chamber Connect the other end to the service drain. 19

20 Manual Base Drain Drains the chamber completely. With the tap handle in the vertical (closed) position, salt fog condensate will accumulate in the chamber base to a predetermined level, before draining to waste. This assists in maintaining a high humidity during testing, and is the correct position for most continuous salt spray tests. With the tap handle in the horizontal (open) position, salt fog condensate will drain away. This drains the chamber interior for cleaning. 20

21 2.3.6 Exhaust Vent to Atmosphere Exhaust 50mm (2 ) diameter pipe for all is chambers. Connect the exhaust pipe provided to the exhaust outlet to the rear of the chamber. If the length of the vent pipe route is greater than 5 metres, a larger diameter pipe may be required. Route the other end to outside atmosphere, maintaining a straight run-up or run-down to avoid sags where condensate may collect and cause backpressure. 21

22 2.3.7 Air Saturator Drain Air Saturator Drain Do not connect anything to the Air Saturator Drain; it is provided for maintenance purposes only. To drain when required: Set the chamber to salt spray mode with the air saturator switched off. Then use a flat bladed screwdriver to open the drain tap. (See section- Running a program / Air saturator mode) Note: If chambers are left unused for any length of time it is recommended that the air saturator is drained to prevent the build-up of algae which could cause system blockages or of bacteria which might present a potential health risk. To drain when required: Reduce the air pressure on the control panel to zero. Then use a flat blade screwdriver to open the drain tap. 22

23 2.4 Atomiser Set up On 450L/1000L & 2000L chambers, the atomiser is mounted in a PVC holder located on the rear wall of the chamber. It is locked into position using plastic thumbscrews. Position and lock the atomiser so that when atomising, the spray impacts in the centre of the inside of the canopy viewing window when the canopy is closed. This position can be adjusted to achieve even fallout results during salt spray testing. 23

24 On 120L chambers, the atomiser is mounted in a PVC holder located on a sideways moveable mount. Position the atomiser so that when atomising, the spray impacts in the sealing gasket between the canopy and the GRP chamber, when the canopy is closed. This position can be adjusted left to right to achieve even fallout results during salt spray testing. Note: Please see the care and maintenance section for details of how to remove and maintain the atomiser. 24

25 Part 3 - Operation 3.1 Human Machine Interface (HMI) Screen The chamber control system utilises a Human Machine Interface (HMI) screen mounted in the chamber control panel. This operates in conjunction with a Programmable Logic Controller (PLC) mounted within the chamber. The HMI screen is touch sensitive and uses virtual push buttons for the selection of various functions. Display LCD screen with backlight. The HMI screen uses a menu driven format, where functions are selected from a variety of pop-up screens. The through the screens. buttons are used to navigate 25

26 3.2 Initial Power Up When the chamber is first switched on; after a few moments, the following screens will be displayed in sequence Contact Details Ascott Main Menu Page: Press the buttons to scroll between screens. After a few moments the screen will display the chamber information screen. 26

27 3.2.2 Chamber Information This screen displays three pieces of information required by an Ascott engineer if contact with Ascott is to be made. They are: Chamber serial number, PLC software revision number and HMI software revision number. Press the buttons to scroll between screens. After a few moments the screen will display the Run screen Run Screen After a few moments the screen will move on to display the Run Screen. Press the buttons to scroll between screens. 27

28 3.3 Run Screen Once the start sequence has completed the screen will display the Run Screen. The Run Screen displays the current status of the chamber. The canopy can also be opened from this page Stopped / Running The Run Screen displays the current status of the chamber. The chamber will be either STOPPED or RUNNING. The canopy can also be opened from this page. 28

29 3.3.2 Starting/Stopping a test Press to start a test. (Hours run counter starts) Press to stop a test. (Hours run counter pauses) Test Mode If you start a test with the canopy open, the chamber will enter test mode. It will start spraying but will not apply any heat to the chamber. It will stop automatically after 5 minutes. The screen will revert to the normal run screen after a short time. 29

30 3.3.4 Canopy Chambers are fitted with a pneumatically operated canopy that opens and closes at the press of a button on the HMI. The chamber must be connected to a suitable compressed air supply before the canopy will open/close. To open the Canopy: From the Run Screen press If no test has been started the canopy can be opened immediately by pressing An alarm will sound for a few seconds and the canopy will open automatically. 30

31 If a test has been started the chamber will need to go through a purge cycle to remove salt fog. An alarm will sound for a few seconds and the canopy will open. Once the purge has completed the canopy can be opened by pressing An alarm will sound for a few seconds and the canopy will open automatically. Once the canopy is open, the chamber can be operated in test mode for five minutes. No heat is applied. 31

32 If the chamber is RUNNING a test and you press, the screen will display this message and will continue testing. The screen will revert to the run screen after a few seconds. To close the Canopy: From the Run Screen, press Note: If you run a test with the canopy open, no heat is applied but the spray atomiser To close the canopy press and hold Keep pressing until the alarm stops. 32

33 3.4 Run Mode The chamber has two operating modes; Setup and Run: Run mode allows the user to view the current status of the chamber. When in Setup mode, the change to Run mode. button is displayed to allow you to When in Run mode, the screens to allow you to change to Setup mode. button is displayed in many of the menu When in Setup mode, press to change to Run mode. Press the buttons to scroll through the various Run screens. Note: Values cannot be adjusted when the chamber is in Run Mode Chamber Temperature Display When in Run Mode the setpoint and actual values for chamber temperature are displayed. No adjustment can be made 33

34 3.4.2 Air Saturator Temperature Display When in Run Mode the set point and actual values for air saturator temperature are displayed. No adjustment can be made Hours Run Display When in Run Mode the hours set, run and remaining are displayed. No adjustment can be made 34

35 3.5 Setup Mode Setup mode allows the user to change the chamber parameters. To enter the Setup mode press Press the screens. buttons to scroll through the various settings Time to stop The chamber can be set to run a test for a predetermined length of time using the Time to Stop facility. The maximum value for this is hrs. If the value hrs is selected, the chamber will continue to run without stopping and the hours run counter will rise accordingly. 35

36 To adjust the value press A key pad will appear. Type in the number required. Press to confirm Press making changes. to escape without Once the test is started, the hours run timer will increase. Once the timer reaches the Time to Stop value the test will stop automatically. If you wish to start a new test you must reset the hours run counter. Press to exit to the run screen immediately. After a short period the screen will revert to the run screen automatically. 36

37 3.5.2 Hours Run Reset To reset the counter to , press Air Saturator (Moist air / Dry Air) In the Moist air mode of operation, compressed air for the salt spray atomiser is bubbled through the chamber air saturator to apply heat and moisture. This is the factory set condition, since this is a requirement of most salt spray test standards. Note: The chamber will automatically revert to this mode whenever the chamber power is switched off and back on again. The current selection is shown in the centre of the display. To change press or 37

38 3.5.4 Pump Speed(s) The peristaltic pump is used to control the flow of salt solution to the atomiser. To adjust the value press A key pad will appear. Type in the number required. Press to confirm Press making changes. to escape without 2000L chambers have two peristaltic pump motors. Pump 1 on the left, pump 2 on the right. Press the button to scroll to the second pump setting. 38

39 To adjust the value press A key pad will appear. Type in the number required. Press to confirm Press making changes. to escape without Chamber Temperature Set point To adjust the value press (Maximum 50C) A key pad will appear. 39

40 Type in the number required. Press to confirm Press making changes. to escape without Air Saturator Temperature Setpoint To adjust the value press (Maximum 63C) A key pad will appear. Type in the number required. Press to confirm Press making changes. to escape without 40

41 3.6 Alarm Status The chamber has a number of inbuilt alarms that will indicate the nature of a potential problem. An alarm buzzer will sound and the screen will be backlit with a red lamp. The nature of the alarm will be displayed. Press to silence the alarm. The screen will return to the run page. If the fault is still present the alarm will re-occur after a few seconds. Press to reset the alarm condition once the cause of the alarm has been investigated and cleared. See section 4.4 Fault finding. 41

42 3.7 Control Emergency Stop Pressing the chamber emergency stop button during canopy opening or closing will freeze the canopy in its current position. An audible alarm sounds. When the emergency stop button is returned to its normal position, the HMI screen will return to the canopy Open/Close screen Mains Isolator Isolates the chamber from the electricity supply. 42

43 3.7.3 Air Pressure Gauge & Regulator Air Pressure Gauge and Regulator These indicate and control the pressure of the compressed air supply to the atomiser(s). They will only operate when air is supplied to the atomisers. To adjust the air pressure: (i). Pull out the regulator knob to unlock. (ii). Rotate anticlockwise to decrease the pressure and clockwise to increase it. (iii). Push in the regulator knob to lock. 43

44 3.7.4 Flow Meter(s) & Peristaltic Pump(s) Flow meters and Peristaltic pumps (2000L- pictured) 450L and 1000L chambers are fitted with one flow meter and one peristaltic pump. 2000L chambers are fitted with two flow meters, and two peristaltic pumps, one of each for each atomiser. The flow meter(s) monitor the flow rate of salt solution from the reservoir to the atomiser(s). The peristaltic pump(s) draw salt solution from the reservoir and pass it to the atomiser(s). 44

45 3.8 Setting Up Procedure Determine the test parameters (i). (ii). (iii). (iv). (v). Salt Spray Test to be performed. Composition of the salt solution. Atomiser air, dry/moist, heated/unheated. Salt fog fall out rate. Test duration. 45

46 3.8.2 Set up chamber (i). (ii). (iii). (iv). (v). Ensure mains isolator is ON. Load the test samples into the chamber. Prepare the salt solution and transfer it to the salt solution reservoir. Ensure that the salt solution reservoir is connected to the chamber. For 120L chambers, fill the integral salt solution reservoir: (vi). Ensure that the drain and exhaust are connected and not blocked. (vii). If pre-humidification of the atomiser air is required and the chamber is not connected to a pressurised supply of deionised water for automatic filling of the Air Saturator, and a manual fill facility has been provided instead (optional accessory), then fill the Air Saturator manually as follows: 46

47 Depressurise the air saturator by selecting dry air within the global settings page. Open the hand operated ball valve at the manual filler port by rotating it fully anticlockwise. Insert a funnel into the open orifice of the manual filler port and slowly fill with deionised or distilled water. Stop filling when high water lamp on the side of the chamber illuminates. Remove the funnel and close the ball valve Reselect moist air within the global settings page. (viii). Press the button to start the test program. (ix). Adjust the pressure regulator and/or the salt solution flow rate to give the required salt fog fall-out rate. 47

48 3.8.3 Set the Salt Fog Fallout Rate (Usually carried out in advance of testing of components) The method for measuring the Salt Fog Fallout Rate is specified as being a 100 mm-diameter funnel in conjunction with a measuring cylinder graduated in millilitres. This procedure is used to collect salt fog fallout at various points across the chamber workspace (no closer than 100 mm from the chamber walls or atomiser) for set periods of time. From these measurements the average fog fallout rate and the spread of the fog throughout the chamber can be determined. Generally, the spread of the fog within the chamber is controlled by the air pressure, and the density of the fog is controlled by the salt solution flow rate. With the atomiser positioned centrally in the chamber, increasing the air pressure will tend to increase the salt fog fallout at the extremes of the chamber, whilst decreasing the air pressure will tend to increase the fallout in the centre of the chamber. Increasing the salt solution flow rate will increase the salt fog fallout at any point in the chamber, whilst decreasing the flow rate will reduce the fallout at any point. Only very small adjustments to the air pressure and flow rate should be made at any one time, before rechecking the results. 48

49 (i). Set the air pressure to between 12 and 18psi (ii). Set the initial flow rate so that the peak flow is approximately 10 to 15 ml/min. The ball in the flow meter will fluctuate up and down with every half revolution of the peristaltic pump. (iii). Adjust the air pressure to obtain an even spread of fog within the chamber, regardless of the actual amount of fallout collected. (iv). (v). Adjust the flow rate to bring the fallout within the limits specified in the test standard. Recheck the spread of the fog and repeat operations iii and iv above until satisfactory. 3.9 Shut down procedure: (i). Stop any running programs. (ii). Switch electrical isolator to OFF. 49

50 Part 4 - Care & Maintenance 4.1 Routine Maintenance Routine maintenance is essential to keep the chamber in good working order. The following maintenance is recommended for a chamber that is in regular use Daily Checks Record chamber variable parameters on the Daily Check Sheet. A sample Daily Check Sheet is provided at the end of this manual. Ensure that corrosion waste or small samples are not gathering in the base of the chamber. This can lead to blockages within the drain system and will affect chamber performance. Contamination may also lead to changes in corrosivity within the chamber that could affect test results! Ensure that the drain is clear. Ensure that the chamber exhaust is clear and is not restricted. Check that deionised water supply is within specification Weekly Maintenance 50

51 Consumables kit Ascott Ref. No.: ACC12/1 A kit of consumables parts is available for Ascott salt spray and cyclic corrosion test chambers. These contain user replaceable items sufficient for up to 1 year. 1m x PERC012 Silicone Tube 2pk x SALC010 - Salt Filter Wadding 1pk x ELEC690 - Cable Ties ATOA110 - Atomiser air in luer fitting assembly ATOA120 - Atomiser salt in luer fitting assembly SALC012 - Salt Filter Housing Tube 51

52 Maintenance of Atomiser Atomiser salt in Atomiser Body & filter Compressed Air Inlet Luer fitting assembly spacer Hose & Atomiser air in Luer fitting assembly Atomiser Cap Salt Solution Inlet Hose Salt solution Filter Housing (filter fitted) Plastic spacer Atomiser Nozzle 1) Check that the chamber service connections are secure and are not leaking. 2) Switch off the power supply to the chamber. 3) Withdraw the atomiser and filter assembly from its support, taking care not to damage the two hose connections. 4) Check the salt solution filter material for discoloration. 5) Disconnect the compressed air inlet hose (BLACK) by rotating the collar of the air in fitting assembly anti clockwise. 6) Unscrew the atomiser body and cap as a complete assembly, from the salt solution filter housing. If the atomiser and cap are dirty or have been giving poor fallout 7) Withdraw the salt solution filter material from the salt solution filter housing using tweezers. 8) Wash the filter material in warm water. 9) If the filter material is badly contaminated or damaged, discard it and replace it with new filter material. 10) Reassemble the salt solution filter. 52

53 Roll the filter material into a cylindrical shape and insert into the filter housing (1&2). (1) (2) Screw the atomiser body, nozzle and cap onto the filter housing ensuring Re-attach the compressed air inlet hose (3). Refit the atomiser and filter assembly onto its mount. Switch on the power supply to the chamber. 3) Gasket check The canopy gasket may occasionally stick to the surface of the chamber body. This may happen if high temperatures are used or if the chamber is left closed for long periods. Apply a thin smear of petroleum jelly or silicone grease to the surface of the gasket material to prevent this. Repeat as required. 53

54 4.1.3 Three Monthly Maintenance Change the silicone rubber tube of the peristaltic pump every three months or earlier if it splits or becomes deformed with usage. Replace the tube as follows: Switch off the chamber. Release the two clamps that hold the silicone rubber tube in the pump body (1). (1) Pull gently on end of silicone rubber tube, whilst turning the pump roller clockwise by hand, to withdraw the tube from the pump (2). Unscrew the cap of the plastic compression fitting on both ends of the silicone tube (3). (2) Pull the two silicone tube ends out of the compression fittings and retain the olive and cap for re-use. Cut a length of new silicone rubber tubing to exactly the same length as the original tubing and fit the compression fitting cap and olive to each end. Reconnect one end of the new tube to the left compression fitting. (3) Place the tube into the left clamp (4) Whilst turning the pump roller clockwise by hand, feed the pipe under the pump roller mechanism until the whole length has been drawn correctly into the pump. Ensure that the tube is not twisted or stretched, and lies naturally in the pump. (4) Clamp the other end of the new tube into the right 54

55 clamp (5). Reconnect the remaining end of the new tube to the right compression fitting (6). (5) Restart pump, and release right clamp for a few minutes to allow the silicone rubber tubing to find its natural position. (6) After Use Remove corrosion waste and any dropped components by scooping out. Do not flush down the drain as this will lead to blockages. Clean the chamber interior and canopy by washing with warm water and mild detergent. If the chamber is not going to be used for a period of one week or longer, refer to unscheduled maintenance section of this manual. 55

56 4.2 Unscheduled Maintenance Storage & Contamination If the chamber is to stand unused for a period of more than one week, or if contamination by algae growth is detected in the salt solution reservoir, the following procedure is recommended: (i). Switch off the chamber. (ii). Drain the air saturator (refer to section 2.3.7). (iii). Discard any salt solution remaining in the reservoir. (iv).clean the reservoir thoroughly. (v). Partly fill the reservoir with a biocidal sterilising agent solution and replace the salt filter housing in the reservoir. (vi).switch on the chamber and run it in the Salt Spray mode of operation for approximately five minutes, with the canopy closed. This will flush all the salt solution hoses and fittings with the sterilising agent. (vii).switch off the chamber and leave to stand until required for use. (viii).discard the sterilising agent and clean the tank thoroughly. (ix).refill the reservoir with salt water and run for approximately five minutes to flush any remaining sterilising agent Deionised Water Inlet Filter (i). Detach deionised water supply hose from the bulkhead fitting at the rear of the chamber. (ii). Withdraw the wire mesh filter from inside the bulkhead fitting. (iii). Scrub the filter clean with a brush under running water, or replace the filter. (iv).re-insert the filter into the bulkhead fitting. (v). Reconnect the deionised water supply. 56

57 4.2.3 Clean or Unblock Salt Spray Atomiser Atomiser salt in Atomiser Body & filter Compressed Air Inlet Hose Atomiser Cap Luer fitting assembly spacer & Atomiser air in Luer fitting assembly Salt Solution Inlet Hose Salt solution Filter Housing (filter fitted) Plastic spacer Atomiser Nozzle Open the chamber canopy Switch off the power supply to the chamber. Withdraw the atomiser and filter assembly from its support, taking care not to damage the two hoses. Detach the compressed air inlet Hose (1). (1) Unscrew the atomiser cap (2). Wash the atomiser cap in warm running water. Unscrew the atomiser body, nozzle and cap 57

58 from the salt solution filter housing. Wash the atomiser body and nozzle in warm running water. (2) If the nozzle is blocked, clear the obstruction by operating the chamber (canopy open) and place atomiser assembly, without the filter attached, into a cup of clean water (3). Water should be drawn through the atomiser to create a spray. (3) Place finger over atomiser outlet to blow air/water back through the atomiser, clearing any obstruction (4). Only if this does not work should the atomiser cone be cleaned with a fine wire. Take care not to damage the cone! (4) Reassemble the Salt Spray Atomiser and test once again (5). (5) 58

59 4.3 Sample Daily Check Sheet Daily Checks for Month: Day Chamber Temp ( C) Air Saturator Temp ( C) Air Pressure (Bar) Fallout (ml/80cm² /hour) ph of Fallout Water Conductivity (µs) % Concentration of Salt Solution

60 4.4 Fault Finding We hope that the ownership of your Ascott corrosion chamber is problem free. But it should be noted that corrosion chambers do benefit form routine servicing and maintenance. Please contact your distributor for details. Additional Technical Support can be found by logging on line to Ascott s Chamber Doctor Application. Access is free during the warranty period of the chamber. Further access can be obtained by contacting Ascott Technical Support. Access to Chamber Doctor is gained by entering the password & login details given on the technical support card, provided. Silver and Gold Technical support packages, can also be purchased for remote technical support, providing direct access to an Ascott engineer after the warranty period has expired. Please contact Ascott Technical Support for assistance on Tel: or Fax

61 4.5 Salt Spray Chamber Exploded Views S120is Control Compartment (Base Plate) 61

62 4.5.1 S120is Front Ascott Chamber 62

63 4.5.1 S120is Rear Ascott Chamber 63

64 4.5.2 S450is Control Compartment (Base Plate) 64

65 4.5.2 S450is Front Ascott Chamber 65

66 4.5.2 S450is Services Panels (Rear External) 66

67 4.5.2 S450is Service Panels (Rear Internal) 67

68 4.5.3 S1000is Control Compartment (Base Plate) 68

69 4.5.3 S1000is Front Ascott Chamber 69

70 4.5.3 S1000is Services Panels (Rear External) 70

71 4.5.3 S1000is Services Panels (Rear Internal) 71

72 4.5.3 S1000is Rear Ascott Chamber 72

73 4.5.3 S2000is Control Compartment (Base Plate) 73

74 4.5.3 S2000is Front Ascott Chamber 74

75 4.5.3 S2000is Services Panel (Rear External) 75

76 4.5.3 S2000is Services Panels (Rear Internal) 76

77 4.5.3 S2000is Rear Ascott Chamber 77

78 4.6 Salt Spray Chamber Exploded Views S120is Air Saturator 78

79 79

80 80

81 4.6.2 S450is, S1000is and S1300is 81

82 82

83 83

84 4.6.3 S2000is and S2600is 84

85 85

86 86

87 4.7 Air Saturators (Glass fabrication) S120is, S450is, S1000is and S1300is 87

88 88

89 89

90 4.7.2 SS200is and SS2600is 90

91 91

92 92

93 5 Optional Accessories Manual (If Ordered) 93

94 Issue Date First Issued Description Of Amendments A Nov 2009 Original Issue ( Draft) B Aug 2010 Change to H&S Statement C June 2011 Multiple updates to specification D June 2011 Test mode reference added F June 2012 CE updates G October 2013 General Updates H February 2014 Updated contents page, layout. I March 2014 Updated Layout, pictures and Headers J March 2014 Updated Layout, Pictures and tables. K June 2014 Updated Atomiser Pictures, tables and Air saturator drain. L March 2015 Updated Layout & services quality warning added M June 2015 Exploded views added N Nov 2015 Added Note regarding gasket maintenance O March 2016 Corrections to numbering, contents pages improved. Part numbers updated P July 2017 Clear Air Saturator details added 94

Cyclic Corrosion Test Chamber Models:

Cyclic Corrosion Test Chamber Models: Cyclic Corrosion Test Chamber Models: CC450/1000/1300/2000/2600iP Instruction Manual CCiP Issue R Ascott Analytical Equipment Limited, 6-8 Gerard, Lichfield Road Industrial Estate, Tamworth, Staffs. B79

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

4.7 Condensation humidity Salt spray IP chambers

4.7 Condensation humidity Salt spray IP chambers 4.7 Condensation humidity Salt spray IP chambers Salt spray IP chambers perform condensation humidity (wetting) in a slightly different way to cyclic corrosion chambers. The manual base drain valve should

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

6900 Maintenance Instruction System Flush

6900 Maintenance Instruction System Flush Equipment Required FA74005 Damper Drain Tube FA16005 Cover Removal Tool FA900005 Beaker 0.25 Litre FA900003 Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves Latex

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: 2244010 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

6800 Maintenance Instruction System Flush Procedure

6800 Maintenance Instruction System Flush Procedure Equipment Required FA74005 FA65318 FA900005 FA900003 Damper Drain Tube 6800 Cover Removal Tool Beaker 0.25 Litre Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves

More information

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: 2244025 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH SPONGE-JET RASP RX3 Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet RASP RX3 User Manual - REV A / DOC: MKT-014-ENG SPONGE-JET

More information

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10 LK product no: PCS 1-10 Article no: 74503 Revision:8 Article no: 74503 Revision: 8 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance of symbols... 5 2.2 Explanatory

More information

MP15 Jockey Pump Controller

MP15 Jockey Pump Controller Setup and Operating Instructions MP15 Jockey Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron Model MP15 Jockey Pump

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

200L BELT DRIVEN AIR COMPRESSOR

200L BELT DRIVEN AIR COMPRESSOR 200L BELT DRIVEN AIR COMPRESSOR MODEL NO: BOXER 14/200 PART NO: 2245215 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 ISS 4 INTRODUCTION Thank you for purchasing this CLARKE 200L Belt

More information

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913 24L AIR COMPRESSOR MODEL NO: RANGER 7/240 PART NO: 2242000 OPERATION & MAINTENANCE INSTRUCTIONS LS0913 INTRODUCTION Thank you for purchasing this CLARKE 24L Air Compressor. Please read this manual fully

More information

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: 2244030 OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product,

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115 AIR COMPRESSOR MODEL NO: CHAMP 3 PART NO: 2225222 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Air Compressor. Please read this manual fully before use

More information

AutoChanger Installation & User Guide Issue 2

AutoChanger Installation & User Guide Issue 2 1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide

More information

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH SPONGE-JET 170-CG Feed Unit USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com AUGUST 2014, Sponge-Jet 170-CG User Manual - REV A / DOC: M-MKTG-002ENG

More information

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512 COMPRESSOR MODEL NO: WARRIOR 55 PART NO: (110V) 2323010, (230V) 2322020, OPERATION & MAINTENANCE INSTRUCTIONS LS0512 INTRODUCTION Thank you for purchasing this CLARKE Compressor. Before attempting to use

More information

Code AWC20HP Air Compressor

Code AWC20HP Air Compressor Code 951816 AWC20HP Air Compressor Index of Contents Index of Contents 02 Declaration of Conformity 02 What s Included 03 Safety Precautions 03 Specifications (AWC20HP Air Compressor) 04 Assembly Instructions

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website: 1.0 Inspection of the product upon receipt: On receipt of the product, visually inspect the item for any evidence of shipping damage. Please note shipping damage is not covered by warranty. If shipping

More information

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation Standard Operating Procedure # Chemical Fume Hood Operation Facility: NMSU College of Engineering Laboratories Written by: Juanita Miller, Safety Specialist, miljgh@nmsu.edu (575)-646-1292 Scope: This

More information

In Vessel Composter Installation & Commissioning Manual

In Vessel Composter Installation & Commissioning Manual In Vessel Composter Installation & Commissioning Manual Contents Customer responsibilities Transportation Lifting Delivery Pre-installation requirements Installation Drainage Ventilation Levelling Unpacking

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

170-SJ Feed UnitTM 470-SJ Feed UnitTM

170-SJ Feed UnitTM 470-SJ Feed UnitTM SPONGE-JET 170-SJ Feed UnitTM 470-SJ Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet 170-SJ / 470-SJ User Manual - REV

More information

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the

More information

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Pressure booster combination DPA-CRVZS. Operating instructions a [ ] Pressure booster combination en Operating instructions 8074546 2017-07a [8074548] Original instructions -EN Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and

More information

Types 749B and R130 Changeover Manifolds

Types 749B and R130 Changeover Manifolds Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies

More information

Operation Manual Air Saver Unit ASV5000 Series

Operation Manual Air Saver Unit ASV5000 Series 9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.

More information

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS) Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS) Sensitivity: 1x10 11 A m 2 Applied DC fields: 0 T to 5 T Applied AC fields: 0 G to 3 G (zero-to-peak), 0.01 Hz to 1000 Hz Temperatures

More information

Ventam 85 Installation & Commissioning Instructions

Ventam 85 Installation & Commissioning Instructions Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Ventam 85 Installation & Commissioning Instructions 1 General The Ventam

More information

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3. Product Specification ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.0 bar Latvin Luxury Shower Panel ~ Fixing Centres 150mm +/- 10mm ~ Outlet size 1/2" Bottom Outlet Always maintain a

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

MD R a n g e O p e r a t o r s H a n d b o o k

MD R a n g e O p e r a t o r s H a n d b o o k MD R a n g e O p e r a t o r s H a n d b o o k Covering Models:- MD35/20 MD75/80 MD75/0 MD75/0V MD75/250 MD75/250V MD0/500 MD225/1000 BAMBI AIR COMPRESSORS LTD 2 Thimble Mill Lane Heartlands Birmingham

More information

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP 50-24 General User and Maintenance Instructions Silentaire Technology 8614 Veterans Memorial Dr. Houston, TX 77088 800-972-7668 Fax 832-327-0669 www.silentaire.com

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Portable Oil Lube Air Compressors

Portable Oil Lube Air Compressors Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

Ascott an introduction. World leaders in salt spray cabinets and cyclic corrosion test (CCT) chambers for corrosion testing

Ascott an introduction. World leaders in salt spray cabinets and cyclic corrosion test (CCT) chambers for corrosion testing Ascott an introduction World leaders in salt spray cabinets and cyclic corrosion test (CCT) chambers for corrosion testing Latest Product Range Who are Ascott? Started in 1989 and specialising only in

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

5 Gallon Pressure Pot with HVLP Spray Gun and Hose California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,

More information

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax OPERATION MANUAL Zutron Medical, LLC 17501 W 98 th St #40-27 Lenexa, KS 66219 Phone 877-343-5873 Fax 913-967-5944 ZUT-Lab-004-30004 REV. 03312017 Table of Contents 2 Introduction 1. Intended Use 2. Labels,

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1

Commercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1 Commercial Softeners Installation, Operation & Maintenance Guide Manual 002.1 Contents Page 1. Unpacking Instructions 3 2. Installation 3 Pre-installation checks Fitting the bottom distribution system

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

50L BELT DRIVEN AIR COMPRESSOR

50L BELT DRIVEN AIR COMPRESSOR 50L BELT DRIVEN AIR COMPRESSOR MODEL NO: BOXER 14/50P PART NO: 2245200, 2245203 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 - ISS 4 INTRODUCTION Thank you for purchasing this CLARKE

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

Safety Section. DANGER: Never enter bin unless all power is locked out and another person is present. Rotating augers can kill or dismember!

Safety Section. DANGER: Never enter bin unless all power is locked out and another person is present. Rotating augers can kill or dismember! Safety Section Read manual before installing or using product. Failure to follow instructions and safety precautions in manual can result in death or serious injury. Keep manual in a safe location for

More information

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap 0509950/2 IM-P050-21 CH Issue 2 Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons Air Flow Capacity 6.2 CFM at 40 PSI 5.2 CFM at 90 PSI Motor 2.5 HP Working / 4 HP Peak 120 Volt / 60 Hz / 13 A / 1-Phase Required

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.: Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.: CONTENTS 1 Contents Page & Introduction 2 Training Requirements & General Safety 3 SFC ED Tool Models Covered By Manual Noise & Vibration Levels 4

More information

MANUAL BE SERIES Test Benches

MANUAL BE SERIES Test Benches The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES

More information

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual ORB-400 BUBBLE/HAZE MACHINE Item ref: 160.462UK User Manual Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty Introduction Thank you for

More information

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents bathrooms.com Concentric Thermostatic Shower Mixers Contents Page 3 - General Information & Safety Page 4 - Installation Page 5 - Concentric Valve Set-up Page 6 - Exposed fitting of Concentric Mixer Valves

More information

with O 2 Controller Instruction Manual

with O 2 Controller Instruction Manual 14500 Coy Drive, Grass Lake, Michigan 49240 734-475-2200 E-mail: sales@coylab.com www.coylab.com Hypoxic Cabinets (In-Vivo / In-Vitro) with O 2 Controller Instruction Manual Index Page Warranty 2 Warnings

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

OPERATION & MAINTENANCE MANUAL NG6/1 YOUR RELIABLE PARNTER IN LABORATORY GAS HANDLING

OPERATION & MAINTENANCE MANUAL NG6/1 YOUR RELIABLE PARNTER IN LABORATORY GAS HANDLING 1 OPERATION & MAINTENANCE MANUAL NG6/1 YOUR RELIABLE PARNTER IN LABORATORY GAS HANDLING 2 CONTENTS CONTACT DETAILS Page 3 SAFETY WARNING Page 4 GENERAL SPECIFICATION Page 6 NG6/1 SPECIFICATION Page 8 PRODUCT

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION This Fitting Guide is designed to assist in the Installation of your Reverse Osmosis System. Some of the parts that are supplied with each system may

More information

Oxygen Dialflow Meter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use Oxygen Dialflow Meter Instructions for Use 702-0031.9 May 2014 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user

More information

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 1499490 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0918 - ISS 2 INTRODUCTION Before attempting to use this product, please read this

More information

Precision Hydrogen (All B&W Screen Models)

Precision Hydrogen (All B&W Screen Models) Precision (All B&W Screen Models) Installation Guide Precision Installation Guide Rev 5 PN IG-PREC-H2 28/03/18 Fittings Kit x1 US Mains Cable C13 6-15 04-1029* x2 Transit Plug 3301437 x1m Tygon Tubing

More information

Instructions for: COMPRESSORS 270ltr belt drive 5.5 / 7.5 hp

Instructions for: COMPRESSORS 270ltr belt drive 5.5 / 7.5 hp Instructions for: COMPRESSORS 270ltr belt drive 5.5 / 7.5 hp 3ph 2-stage model No's: SAC42755BLN, SAC72775BLN Thank you for purchasing a Sealey product. Manufactured to a high standard this product will,

More information

Universal Valve Company Inc

Universal Valve Company Inc Universal Valve Company Inc 800-223-0741 www.universalvalve.com 1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Free Air Universal

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100 SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100 OPERATING & MAINTENANCE INSTRUCTIONS 0306 Thank you for purchasing this CLARKE Shhh Air silent running air compressor Before attempting to

More information

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury. 2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment) 3810050/5 IM-P381-01 CH Issue 5 SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment) Installation and Maintenance Instructions 1. Safety information 2. Use 3.

More information

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL 2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,

More information

Model Air Caddy Orig TABLE OF CONTENTS

Model Air Caddy Orig TABLE OF CONTENTS 92-0919 Orig. 020201 Model 75-0114 Air Caddy TABLE OF CONTENTS CUSTOMER MESSAGE Inside Front Cover SAFETY PRECAUTIONS 3 GENERAL DESCRIPTION 6 SPECIFICATIONS 7 MAINTENANCE 9 INSTALLATION AND OPERATION 11

More information

2 Sentry MCL Installation, Operation & Maintenance

2 Sentry MCL Installation, Operation & Maintenance Gas Liquid & Slurry Solid & Powder Steam & Water Installation, Operation & Maintenance Manual Original Instructions Liquid Sampling Manual Low-Emission Samplers S-GA-IOM-00249-7 11-17 Sentry MCL 966 Blue

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

ELECTRONIC PLC SERIES Test Benches

ELECTRONIC PLC SERIES Test Benches Whether you are producing a single assembly or a production run, CustomCrimp has the test equipment to give both you and your customer the assurance that the product has been assembled correctly. A programmable

More information

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May 2015 98-0520 S/N 2001 N. Indianwood Ave. Tulsa, Oklahoma 74012 U.S.A. TEL: (918) 250-7200 FAX: (918) 459-0165 E-mail: chandler.sales@ametek.com

More information

Anti-flood device Model B-1

Anti-flood device Model B-1 December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of CO 2 Incubator PC-POD-CA-007-v03 Revision History Version Reason for Revision Date 01 New POD 30-Sep-13 02 Minor revisions for section 2.3, 3.1, 4.3. 14-April-16

More information

Instructions for Use

Instructions for Use Select-380 T-Auto T-Auto Contents Page Instructions for Use Ref: 3.0 IFU 380 T-Auto Mar 18 2 Schematic layout of the doser 3 Quick-fit instructions 4 Description/Installation/Operation Pump tubes & Water

More information

GAS BBQ 4 burner. instructions for. model no: BBQ10

GAS BBQ 4 burner. instructions for. model no: BBQ10 instructions for GAS BBQ 4 burner model no: BBQ10 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained,

More information

Hydraulic Punch Drivers

Hydraulic Punch Drivers SERVICE MANUAL 7804SB / 7806SB Quick Draw 7704SB / 7706SB Quick Draw Flex Quick Draw Hydraulic Punch Drivers Serial Codes AHJ and YZ Read and understand all of the instructions and safety information in

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

Propane Conversion Kit Instructions

Propane Conversion Kit Instructions 604 8 0/ US/CA For heating engineers Propane Conversion Kit Instructions Logano G4 X gas-fired boiler This conversion kit and the accompanying instructions are for conversion of G4 X gas-fired boilers

More information

Inert Air (N2) Systems Manual

Inert Air (N2) Systems Manual INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap 1250650/6 IM-P125-07 ST Issue 6 MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

Installing ASI Umbilical Delivery Systems

Installing ASI Umbilical Delivery Systems Rev A 05 Nov 2015 Page 1 of 10 PURPOSE This guide provides an overview of tubing connections into an ASI wall-mounted Junction Box that has already been plumbed with a compressed air connection including

More information

Training. Testor Training Manual

Training. Testor Training Manual Training Testor Training Manual Index Section 1 Introduction and Safety Warnings Section 2 Test Procedures Section 3 Test Hoses Section 4 Fault Location 1:1 1.1 Introduction The Dräger Testor test equipment

More information