CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ. Semester 2 Examinations 2010

Size: px
Start display at page:

Download "CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ. Semester 2 Examinations 2010"

Transcription

1 CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ Semester 2 Examinations 2010 School: Mechanical & Process Engineering Programme Title: Bachelor of Science (Honours) in Advanced Manufacturing Technology & Bachelor of Science (Honours) in Process Plant Technology. Programme Code: CR_EAMTE_8, CR_EPPTE_8 Module Title: Maintenance & Reliability Module Code: MANU8003 External Examiner(s): Internal Examiner(s): Mr. Neil Kingston, Mr. Joe Phelan Mr. Dan O Brien Instructions: Answer any 3 questions Duration: 2 hours Sitting: Summer 2010 Requirements for this examination: Probability Plotting Paper, Hazard Plotting Paper, Log-Log Paper, Log Tables & Statistical Tables. Note to Candidates: Please check the Programme Title and the Module Title to ensure that you are attempting the correct examination. If in doubt please contact an Invigilator. Page 1 of 11

2 Q. 1 Reliability Modelling : (a) Differentiate between MTBF and MTTF. (3 marks) (b) The exponential distribution is used to model items with a constant failure rate, Its probability density function, pdf, is given by: x 1 f ( x) = e θ λx = λe, x 0 θ Derive the reliability function and the hazard function from first principles. (10 marks) (c) The equipment in a packaging plant has a failure rate of 0.001/hr. What is the probability of operating for a period of 500hr without failure? (8 marks) (d) Briefly discuss the use of confidence intervals in reliability. (5 marks) (e) In reliability testing to estimate MTBF two situation exist: 1. Type 1 censoring: for which the lower one sided confidence limit is: 2T 2 χ ( α,2r+2) θ 2. Type 2 censoring: for which the lower one sided confidence limit is 2T 2 χ ( α,2r ) θ A unit is tested for a total of 3000hours. When testing was stopped after 3000hr, it was noted that three failures had occurred during testing. Calculate the 90% confidence on the one-sided lower limit for the MTBF (θ) (7 marks) Page 2 of 11

3 Q. 2 Probability Plotting (a) The cumulative hazard function may be plotted using hazard papers. Discuss the advantages of using this method over Weibull papers. (5 marks) (b) The data below relate to failures of terminations in a sample of 20 semiconductor devices. Each failure results from breaking of either the wire (W) or the bond (B) whichever is the weaker. The specification requirement is that fewer than 1 per cent of terminations shall have strengths of less than 500g. Table 1. Failures of terminations of semiconductor devices. Failure B or W Failure load B or W load (mg) (mg) 550 B 1250 B 750 W 1350 W 950 B 1450 B 950 W 1450 B 1150 W 1450 W 1150 B 1550 B 1150 B 1550 W 1150 W 1550 W 1150 W 1850 W 1250 B 2050 B Estimate Weibull parameters for (i) termination strength, (ii) wire strength, (iii) bond strength. Comment on the results. (12 marks) (c) Briefly describe the Duane model of Reliability Growth (6 marks) (d) A prototype of a repairable system was subjected to a test programme where engineering action is supposedly taken to eliminate causes of failure as they occur. The first 500hrs of running gave failures at 12, 36, 80, 120, 200, 360, 400, 440 and 480hrs. Produce a Duane plot (using the attached log-log paper) to discover whether reliability growth is occurring. (10 marks) Page 3 of 11

4 Q. 3 Reliability in Design/Human Reliability (a) What is the purpose of an FMEA and explain how it is performed, detailing what information is analysed and the significance of RPN? (8 marks) (b) A pressure vessel is shown in Figure 1 beneath. The safety system consists of 4 valves, which are connected to the tank. The valves will open if the pressure in the tank exceeds a certain level, for example P 0. The contents in the tank will be release to the environment if both valves A 1 and A 2 on line 1 or both valves A 3 and A 4 on line 2 are open. A 2 A 4 A 1 A 3 Figure 1. Arrangement of pressure tank and valves (i) Develop a Fault tree for system failure of the above tank.( i.e. the valves do not open when the pressure in the tank exceeds P 0 state any assumptions) (10 marks) (c) Describe the Robust Design Approach. (8 marks) (d) An operator works on a production transfer line which operates between two tanks. His role is to ensure the correct product is selected for transfer from one tanker to the other; this can be done by operation of the relevant valves which are located remotely. The essential valves must be opened to allow the task to be carried out. The operator possesses average experience in fulfilling this role. The individual is situated in a control room which has a relatively noisy environment and poor lighting. There is a time window of 5 minutes to carry out the required task. Determine the Human Error Probability using the TESEO method. TESEO values are presented in Table 3. (7 marks) Page 4 of 11

5 Q. 4 Maintenance Management / Inventory Managament (a) Differentiate between TPM and RCM. (6 marks) (b) Discuss the use of Maintenance Time Distributions as a means of predicting time to repair. (8 marks) (c) Spare parts management is divided into slow moving spares and fast moving spares. Describe both policies. (5 marks) (d) In one year, 200 components of similar type were issued out from a store. If the demand for this part was relatively constant: (i) specify an appropriate inventory policy (ii) quantify the policy parameters given the following information: lead time L = 3 weeks order cost C O = 0.80 spares holding cost C H = 0.20/yr. (7 marks) (e) The failure distribution of a component is described by a 2-parameter Weibull distribution, with β = 2.5 and θ = 1000 hours. The cost for a corrective replacement is 6. The cost for a preventive replacement is 1. Estimate the optimum replacement age in order to minimize these costs given T = mθ + δ (7 marks) Page 5 of 11

6 Figure 2 Hazard Plotting Paper Page 6 of 11

7 Table 2 Table of Median Ranks Page 7 of 11

8 Figure 3 Weibull Distribution Function Plotting Paper Page 8 of 11

9 Figure 4 Log Log Paper Page 9 of 11

10 Table 3 TESEO Error probabilities TESEO error probabilities Type of activity factor K 1 Simple routine Requiring attention, but routine 0.01 Not routine 0.1 Temporary stress factor, for routine activities K 2 Time available, in seconds Temporary stress factor, for nonroutine activities K 2 Time available, in seconds Operator qualities K 3 Carefully selected, highly trained 0.5 Average knowledge and training 1 Little knowledge and training 3 Activity anxiety factor K 4 Situation of grave emergency 3 Situation of potential emergency 2 Normal situation 1 Activity ergonomic factor K 5 Excellent working conditions and a well designed interface 0.7 Good Working conditions and a good interface design 1 Tolerable working conditions and a tolerable interface 3 design Tolerable working conditions and a poor interface design 7 Poor working conditions and a poor interface design 10 Page 10 of 11

11 Table 4 Optimum Parts Replacement Values for m C f /C p β Page 11 of 11

Ch.5 Reliability System Modeling.

Ch.5 Reliability System Modeling. Certified Reliability Engineer. Ch.5 Reliability System Modeling. Industrial Engineering & Management System Research Center. - 1 - Reliability Data. [CRE Primer Ⅵ 2-6] Sources of Reliability Data. Successful

More information

Analysis of Instrumentation Failure Data

Analysis of Instrumentation Failure Data Analysis of Instrumentation Failure Data A structured approach Standards Certification Education & Training Publishing Conferences & Exhibits Matthew F. (Matt) Murphy Senior Consultant, DuPont Engineering

More information

Chapter 20. Planning Accelerated Life Tests. William Q. Meeker and Luis A. Escobar Iowa State University and Louisiana State University

Chapter 20. Planning Accelerated Life Tests. William Q. Meeker and Luis A. Escobar Iowa State University and Louisiana State University Chapter 20 Planning Accelerated Life Tests William Q. Meeker and Luis A. Escobar Iowa State University and Louisiana State University Copyright 1998-2008 W. Q. Meeker and L. A. Escobar. Based on the authors

More information

Safety Manual VEGAVIB series 60

Safety Manual VEGAVIB series 60 Safety Manual VEGAVIB series 60 Contactless electronic switch Document ID: 32002 Contents Contents 1 Functional safety... 3 1.1 General information... 3 1.2 Planning... 4 1.3 Adjustment instructions...

More information

DATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report

DATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report DATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report Number: Approval Date: 20160106 AMSC Number: N9616 Limitation: No DTIC Applicable: Yes GIDEP Applicable: Yes Defense

More information

Reliability Analysis of the LabTecta Bearing Protector

Reliability Analysis of the LabTecta Bearing Protector Reliability Analysis of the LabTecta Bearing Protector This article examines the statistical life expectancy of the LabTecta bearing protector, supplied by AESSEAL. The LabTecta is an IEEE 841-2001 and

More information

Software Reliability 1

Software Reliability 1 Software Reliability 1 Software Reliability What is software reliability? the probability of failure-free software operation for a specified period of time in a specified environment input sw output We

More information

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1* Safety Manual Process pressure transmitter IPT-1* 4 20 ma/hart Process pressure transmitter IPT-1* Contents Contents 1 Functional safety 1.1 General information... 3 1.2 Planning... 4 1.3 Instrument parameter

More information

Safety Manual VEGAVIB series 60

Safety Manual VEGAVIB series 60 Safety Manual VEGAVIB series 60 NAMUR Document ID: 32005 Contents Contents 1 Functional safety... 3 1.1 General information... 3 1.2 Planning... 4 1.3 Adjustment instructions... 6 1.4 Setup... 6 1.5 Reaction

More information

Reliability predictions in product development. Proof Engineering Co

Reliability predictions in product development. Proof Engineering Co Reliability predictions in product development Proof Engineering Co Contents Review of reliability theory Ways to predict part reliability Converting parts reliability into a system reliability Ways to

More information

Safety Manual OPTISWITCH series relay (DPDT)

Safety Manual OPTISWITCH series relay (DPDT) Safety Manual OPTISWITCH series 5000 - relay (DPDT) 1 Content Content 1 Functional safety 1.1 In general................................ 3 1.2 Planning................................. 5 1.3 Adjustment

More information

Reliability engineering is the study of the causes, distribution and prediction of failure.

Reliability engineering is the study of the causes, distribution and prediction of failure. Reliability engineering: Reliability is the probability that a system or component will perform without failure for a specified period of time under specified operating conditions. Reliability engineering

More information

Failure Data Analysis for Aircraft Maintenance Planning

Failure Data Analysis for Aircraft Maintenance Planning Failure Data Analysis for Aircraft Maintenance Planning M. Tozan, A. Z. Al-Garni, A. M. Al-Garni, and A. Jamal Aerospace Engineering Department King Fahd University of Petroleum and Minerals Abstract This

More information

Electrical Equipment Failures Cause & Liability. Prepared by: Robert Abend, PE on 11 August 2014

Electrical Equipment Failures Cause & Liability. Prepared by: Robert Abend, PE on 11 August 2014 Electrical Equipment Failures Cause & Liability Prepared by: Robert Abend, PE on 11 August 2014 About the Author Robert (Bob) Abend gained his initial career experience in the semiconductor component industry

More information

The Safety Case. Structure of Safety Cases Safety Argument Notation

The Safety Case. Structure of Safety Cases Safety Argument Notation The Safety Case Structure of Safety Cases Safety Argument Notation Budapest University of Technology and Economics Department of Measurement and Information Systems The safety case Definition (core): The

More information

Review and Assessment of Engineering Factors

Review and Assessment of Engineering Factors Review and Assessment of Engineering Factors 2013 Learning Objectives After going through this presentation the participants are expected to be familiar with: Engineering factors as follows; Defense in

More information

DP Station Keeping Event Bulletin

DP Station Keeping Event Bulletin DP Station Keeping Event Bulletin IMCA DP Station Keeping Event Bulletin 04/17 October 2017 The following event trees have been compiled from recent reports received by IMCA. The originators granted IMCA

More information

Technical Standards and Legislation: Risk Based Inspection. Presenter: Pierre Swart

Technical Standards and Legislation: Risk Based Inspection. Presenter: Pierre Swart Technical Standards and Legislation: Risk Based Inspection Presenter: Pierre Swart Agenda Change in Legislation. Where RBI fits in. Application to implement RBI. RBI concepts. Elements of an RBI analysis.

More information

model for functional safety of

model for functional safety of Application of Weibull reliability model for functional safety of electro-hydraulic system 1 When the safety of the machinery users relies on a reliable function of the control system, than a safety function

More information

DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508

DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508 DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508 Simon J Brown Technology Division, Health & Safety Executive, Bootle, Merseyside L20 3QZ, UK Crown Copyright

More information

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions SIL SM.018 Rev 1 FP15 Interface Valve Compiled By : G. Elliott, Date: 30/10/2017 FP15/L1 FP15/H1 Contents Terminology Definitions......3 Acronyms & Abbreviations...4 1. Introduction...5 1.1 Scope.. 5 1.2

More information

Hazard Operability Analysis

Hazard Operability Analysis Hazard Operability Analysis Politecnico di Milano Dipartimento di Energia HAZOP Qualitative Deductive (search for causes) Inductive (consequence analysis) AIM: Identification of possible process anomalies

More information

Operating instructions Electrical switching facility pco

Operating instructions Electrical switching facility pco Operating instructions Electrical switching facility pco from software version V1.33 on TABLE OF CONTENTS 1. Before you start... 4 1.1 Brief description... 4 1.2 Using this manual... 4 2. pco integrated

More information

MDEP Common Position No AP

MDEP Common Position No AP MDEP Validity: until net update or archiving MDEP Common Position No AP1000-01 Related to : AP1000 Working Group activities THE DESIGN AND USE OF EXPLOSIVE - ACTUATED (SQUIB) VALVES IN NUCLEAR POWER PLANTS

More information

C. Mokkapati 1 A PRACTICAL RISK AND SAFETY ASSESSMENT METHODOLOGY FOR SAFETY- CRITICAL SYSTEMS

C. Mokkapati 1 A PRACTICAL RISK AND SAFETY ASSESSMENT METHODOLOGY FOR SAFETY- CRITICAL SYSTEMS C. Mokkapati 1 A PRACTICAL RISK AND SAFETY ASSESSMENT METHODOLOGY FOR SAFETY- CRITICAL SYSTEMS Chinnarao Mokkapati Ansaldo Signal Union Switch & Signal Inc. 1000 Technology Drive Pittsburgh, PA 15219 Abstract

More information

Reliability Growth of Stirling-Cycle Coolers at L-3 CE

Reliability Growth of Stirling-Cycle Coolers at L-3 CE Reliability Growth of Stirling-Cycle Coolers at L-3 CE R. Estrada, D. T. Kuo, and Q. K. Phan L-3 Cincinnati Electronics Pasadena, CA 91107 ABSTRACT The objective of this paper is to present updated reliability

More information

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS

QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS QUANTIFYING THE TOLERABILITY OF POTENTIAL IGNITION SOURCES FROM UNCERTIFIED MECHANICAL EQUIPMENT INSTALLED IN HAZARDOUS AREAS Steve Sherwen Senior Consultant, ABB Engineering Services, Daresbury Park,

More information

The Safety Case. The safety case

The Safety Case. The safety case The Safety Case Structure of safety cases Safety argument notation Budapest University of Technology and Economics Department of Measurement and Information Systems The safety case Definition (core): The

More information

A quantitative software testing method for hardware and software integrated systems in safety critical applications

A quantitative software testing method for hardware and software integrated systems in safety critical applications A quantitative software testing method for hardware and software integrated systems in safety critical applications Hai ang a, Lixuan Lu* a a University of Ontario Institute of echnology, Oshawa, ON, Canada

More information

Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis

Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis Mary Ann Lundteigen and Marvin Rausand mary.a.lundteigen@ntnu.no RAMS Group Department of Production and Quality Engineering

More information

Moor, Tend Mooring And Unmoor Ship - Supervisor Level -

Moor, Tend Mooring And Unmoor Ship - Supervisor Level - Marine Terminal Operations Competency Standard Moor, Tend Mooring And Unmoor Ship - Supervisor Level - Industry : Oil, Chemical and Gas Industry Competency Category : 2.0 Moor, tend mooring and unmoor

More information

Determining Occurrence in FMEA Using Hazard Function

Determining Occurrence in FMEA Using Hazard Function Determining Occurrence in FMEA Using Hazard Function Hazem J. Smadi Abstract FMEA has been used for several years and proved its efficiency for system s risk analysis due to failures. Risk priority number

More information

Reliability. Sistem Perawatan TIP FTP UB 1 -

Reliability. Sistem Perawatan TIP FTP UB 1 - Reliability Sistem Perawatan TIP FTP UB 1 - Outline Strategic Importance of Maintenance and Reliability Reliability Improving Individual Components Providing Redundancy 2 - Learning Objectives When you

More information

Understanding safety life cycles

Understanding safety life cycles Understanding safety life cycles IEC/EN 61508 is the basis for the specification, design, and operation of safety instrumented systems (SIS) Fast Forward: IEC/EN 61508 standards need to be implemented

More information

Coriolis Mass Flow Meter

Coriolis Mass Flow Meter Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;

More information

Param Express. Param Sankalp December Newsletter winners. Key Activities Concluded. Watch Out For

Param Express. Param Sankalp December Newsletter winners. Key Activities Concluded. Watch Out For Param Express Param Sankalp December Newsletter winners Key Activities Concluded Based on RCM expert input Refinements incorporation is in progress for 1 st set of 10 equipment s. Notification generated

More information

NITRON MG SERIES MEMBRANE NITROGEN GENERATORS

NITRON MG SERIES MEMBRANE NITROGEN GENERATORS Highest efficient membrane technology Top quality membranes with the highest permeability feature Nitrogen purity range between %95 and % 99.5 Few moving parts Compact and ergonomic Integrated skid mounted

More information

CONTROL and INSTRUMENTATION

CONTROL and INSTRUMENTATION CONTROL and INSTRUMENTATION COURSE 500: 5 DAYS: Max 8 Candidates This course covers the key aspects of current instrumentation and process control technology and is designed to enable maintenance personnel

More information

Hydraulic (Subsea) Shuttle Valves

Hydraulic (Subsea) Shuttle Valves SIL SM.009 0 Hydraulic (Subsea) Shuttle Valves Compiled By : G. Elliott, Date: 11/3/2014 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant Standards

More information

How to Design Medical Accelerator Systems for Reliability: IBA PT System

How to Design Medical Accelerator Systems for Reliability: IBA PT System How to Design Medical Accelerator Systems for Reliability: IBA PT System Yves Jongen Founder & Chief Research Officer Ion Beam Applications s.a. Belgium 1 Outline A short introduction of a proton therapy

More information

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES Industry Guidelines Part 2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES ISSUE 5.1 Ref: POP10B 15 MAR 2010 Disclaimer In formulating this guideline PIPA has relied

More information

Simple Time-to-Failure Estimation Techniques for Reliability and Maintenance of Equipment

Simple Time-to-Failure Estimation Techniques for Reliability and Maintenance of Equipment F E A T U R E A R T I C L E Simple Time-to-Failure Estimation Techniques for Reliability and Maintenance of Equipment Key Words: Reliability and maintenance, time-to-failure estimation, reactive maintenance

More information

Per Section I of the ASME

Per Section I of the ASME notifies the control room or other Maintenance Safer & Easier remote locations that a probe column The system s intelligence can BOILER INSPECTION GUIDELINES FOR distinguish dirty probes from BOILER INSPECTION

More information

Solenoid Valves For Gas Service FP02G & FP05G

Solenoid Valves For Gas Service FP02G & FP05G SIL Safety Manual SM.0002 Rev 02 Solenoid Valves For Gas Service FP02G & FP05G Compiled By : G. Elliott, Date: 31/10/2017 Reviewed By : Peter Kyrycz Date: 31/10/2017 Contents Terminology Definitions......3

More information

Quality Planning for Software Development

Quality Planning for Software Development Quality Planning for Software Development Tom Walton Alcatel Networks tom.waltoniliiialcatel.com Abstract A historical project is used as a reference model for the verification planning process. The planning

More information

Presented to the Israel Annual Conference on Aerospace Sciences, 2009 RISK-ANALYSIS A SUPPLEMENT TO DAMAGE-TOLERANCE ANALYSIS

Presented to the Israel Annual Conference on Aerospace Sciences, 2009 RISK-ANALYSIS A SUPPLEMENT TO DAMAGE-TOLERANCE ANALYSIS RISK-ANALYSIS A SUPPLEMENT TO DAMAGE-TOLERANCE ANALYSIS Abraham Brot Engineering Division Israel Aerospace Industries Ben-Gurion Airport, Israel abrot@iai.co.il ABSTRACT Risk-analysis, based on probabilistic

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Solenoid Drivers KFD2-SL2-(Ex)1.LK.vvcc KFD2-SL2-(Ex)*(.B).vvcc Customer: Pepperl+Fuchs GmbH Mannheim Germany Contract No.: P+F 06/09-23 Report No.:

More information

Return to Session Menu DYNAMIC POSITIONING CONFERENCE QUALITY ASSURANCE SESSION. The Meaning of LIFE. Richard Purser GL Noble Denton

Return to Session Menu DYNAMIC POSITIONING CONFERENCE QUALITY ASSURANCE SESSION. The Meaning of LIFE. Richard Purser GL Noble Denton Return to Session Menu DYNAMIC POSITIONING CONFERENCE October 15-16, 2013 QUALITY ASSURANCE SESSION The Meaning of LIFE Richard Purser GL Noble Denton The Meaning of Life 15 th October 2013 What is the

More information

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 / Smart positioner YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 / 3410 / 3450 Series SIL Safety Instruction. Supplement to product manual July. 2015 YTC Ver 1.06 1 Table of contents 1 Introduction... 3 1.1

More information

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary ADH 1/7/014 LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary This experiment will introduce you to the kinetic properties of low-pressure gases. You will make observations on the

More information

Gravity Probe-B System Reliability Plan

Gravity Probe-B System Reliability Plan Gravity Probe-B System Reliability Plan Document #P0146 Samuel P. Pullen N. Jeremy Kasdin Gaylord Green Ben Taller Hansen Experimental Physics Labs: Gravity Probe-B Stanford University January 23, 1998

More information

Section I: Multiple Choice Select the best answer for each problem.

Section I: Multiple Choice Select the best answer for each problem. Inference for Linear Regression Review Section I: Multiple Choice Select the best answer for each problem. 1. Which of the following is NOT one of the conditions that must be satisfied in order to perform

More information

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies

CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN. Energy Control Technologies PLANT AIR CONTROL SYSTEMS CONTROL SOLUTIONS DESIGNED TO FIT RIGHT IN Maximizing your plant s efficiency with plant air control systems built to fit your needs exactly. Energy Control Technologies E nergy

More information

The Next Generation for Level Control. By Ryan Spooner, Singer Valve

The Next Generation for Level Control. By Ryan Spooner, Singer Valve The Next Generation for Level Control By Ryan Spooner, Singer Valve The Next Generation for Level Control Water is an essential resource to everyday life and therefore having a way to store and distribute

More information

Selecting Maintenance Tactics Section 4

Selecting Maintenance Tactics Section 4 ARE 24 Facilities Maintenance Management Prepared By: KAMAL A. BOGES # 2321 November 2 nd, 2003 Selecting Maintenance Tactics Section 4 Uptime Strategies for Excellence in Maintenance Management By: John

More information

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100 107 W. Main Street Worthington, PA 16262 Phone: 724.297.3416 Fax: 724.297.5189 http://www.airtak.com OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100 12-2007 TABLE OF CONTENTS PAGE

More information

Fail Operational Controls for an Independent Metering Valve

Fail Operational Controls for an Independent Metering Valve Group 14 - System Intergration and Safety Paper 14-3 465 Fail Operational Controls for an Independent Metering Valve Michael Rannow Eaton Corporation, 7945 Wallace Rd., Eden Prairie, MN, 55347, email:

More information

Proof Testing A key performance indicator for designers and end users of Safety Instrumented Systems

Proof Testing A key performance indicator for designers and end users of Safety Instrumented Systems Proof Testing A key performance indicator for designers and end users of Safety Instrumented Systems EUR ING David Green BEng(hons) CEng MIET MInstMC RFSE Ron Bell OBE BSc CEng FIET Engineering Safety

More information

MAINTENANCE AND OPERATING MANUAL

MAINTENANCE AND OPERATING MANUAL MAINTENANCE AND OPERATING MANUAL Cyclone condensate separator Type ASA EN EN Maintenance and operating manual Purpose and appropriate use Dear Customer, thank you for choosing our product. In order to

More information

USING A PROBABILITY APPROACH TO RANK IN-LINE INSPECTION ANOMALIES FOR EXCAVATION AND FOR SETTING REINSPECTION INTERVALS

USING A PROBABILITY APPROACH TO RANK IN-LINE INSPECTION ANOMALIES FOR EXCAVATION AND FOR SETTING REINSPECTION INTERVALS USING A PROBABILITY APPROACH TO RANK IN-LINE INSPECTION ANOMALIES FOR EXCAVATION AND FOR SETTING REINSPECTION INTERVALS by Dennis C. Johnston and Carolyn E. Kolovich Kiefner & Associates, Inc. P.O. Box

More information

Learn more at

Learn more at IBP1833_06 COST EFFICIENT ARTIFICIAL BUOYANT SEABED DRILLING SOLUTION Dan Moutrey 1, Frank Lim 2 Copyright 2006, Instituto Brasileiro de Petróleo e Gás - IBP This Technical Paper was prepared for presentation

More information

YT-300 / 305 / 310 / 315 / 320 / 325 Series

YT-300 / 305 / 310 / 315 / 320 / 325 Series Volume Booster YT-300 / 305 / 310 / 315 / 320 / 325 Series SIL Safety Instruction. Supplement to product manual Apr. 2016 YTC Ver. 2.01 1 Table of contents 1 Introduction... 3 1.1 Purpose of this document...

More information

ASSESSING THE RELIABILITY OF FAIL-SAFE STRUCTURES INTRODUCTION

ASSESSING THE RELIABILITY OF FAIL-SAFE STRUCTURES INTRODUCTION ASSESSING THE RELIABILITY OF FAIL-SAFE STRUCTURES Abraham Brot * Abstract: A computer simulation method is described, that can be used to assess the reliability of a dual-path fail-safe design. The method

More information

CHAPTER 28 DEPENDENT FAILURE ANALYSIS CONTENTS

CHAPTER 28 DEPENDENT FAILURE ANALYSIS CONTENTS Applied R&M Manual for Defence Systems Part C - Techniques CHAPTER 28 DEPENDENT FAILURE ANALYSIS CONTENTS Page 1 Introduction 2 2 Causes of Dependent Failures 3 3 Solutions 4 Issue 1 Page 1 Chapter 28

More information

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik Dr. Thiedig Anlagen- und Analysentechnik DIGOX 5 CO In-line measurement of CO for constant product quality DIGOX 5 CO the robust system for CO measurement in the beverage industry The content of dissolved

More information

B.H. Far

B.H. Far SENG 521 Software Reliability & Software Quality Chapter 13: Applying Failure Data to Guide Decision Department t of Electrical l & Computer Engineering, i University it of Calgary B.H. Far (far@ucalgary.ca)

More information

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA Failure Modes, Effects and Diagnostic Analysis Project: 3095MV Mass Flow Transmitter Customer: Rosemount Inc. Chanhassen, MN USA Contract No.: Q04/04-09 Report No.: Ros 04/04-09 R001 Version V1, Revision

More information

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Application Positioner firmware for early detection of control valve faults giving maintenance recommendations. Valid

More information

CHAPTER 4 FMECA METHODOLOGY

CHAPTER 4 FMECA METHODOLOGY CHAPTER 4 FMECA METHODOLOGY 4-1. Methodology moving into Criticality Analysis The FMECA is composed of two separate analyses, the FMEA and the Criticality Analysis (CA). The FMEA must be completed prior

More information

Probability Risk Assessment Methodology Usage on Space Robotics for Free Flyer Capture

Probability Risk Assessment Methodology Usage on Space Robotics for Free Flyer Capture 6 th IAASS International Space Safety Conference Probability Risk Assessment Methodology Usage on Space Robotics for Free Flyer Capture Oneil D silva Roger Kerrison Page 1 6 th IAASS International Space

More information

Ultima. X Series Gas Monitor

Ultima. X Series Gas Monitor Ultima X Series Gas Monitor Safety Manual SIL 2 Certified " The Ultima X Series Gas Monitor is qualified as an SIL 2 device under IEC 61508 and must be installed, used, and maintained in accordance with

More information

4m Blanco Glycol Chiller system: history, recent events, present status and plans

4m Blanco Glycol Chiller system: history, recent events, present status and plans 4m Blanco Glycol Chiller system: history, recent events, present status and plans Brooke Gregory, Esteban Parkes, Chris Smith 22 May 2012 Background Information: Original configuration (from ~1975) of

More information

NATURAL GAS MAINTENANCE. Part 192 Subpart "M"

NATURAL GAS MAINTENANCE. Part 192 Subpart M NATURAL GAS MAINTENANCE Part 192 Subpart "M" CONTACT INFORMATION Pamela West Pipeline Safety Specialist U.S. Department of Transportation PHMSA Inspector Training and Qualifications Main: (405) 686-2310

More information

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions SIL SM.0010 1 Pneumatic QEV Compiled By : G. Elliott, Date: 8/19/2015 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant Standards 5 1.3 Other

More information

Service & Support. Questions and Answers about the Proof Test Interval. Proof Test According to IEC FAQ August Answers for industry.

Service & Support. Questions and Answers about the Proof Test Interval. Proof Test According to IEC FAQ August Answers for industry. Cover sheet Questions and Answers about the Proof Test Interval Proof Test According to IEC 62061 FAQ August 2012 Service & Support Answers for industry. Contents This entry originates from the Siemens

More information

Commissioning and safety manual

Commissioning and safety manual Commissioning and safety manual CNL35L DNL35L SIL2 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact: Commercial@Loreme.fr

More information

NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD

NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD NSS/HP-1740.1 This Standard was CANCELLED on Jul 30 2002 22 FEBRUARY 1974 NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD OFFICE OF SAFETY AND RELIABILITY AND QUALITY ASSURANCE NATIONAL AERONAUTICS AND

More information

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12 LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/ This experiment will introduce you to the kinetic properties of low-pressure gases. You will make observations on the rates with which selected

More information

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION Application Note Doc. G8108-001 Rev. A - 23-Jul-02 ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION For more information regarding Digiquartz products contact: Paroscientific,

More information

High Integrity Pressure Protection Systems HIPPS

High Integrity Pressure Protection Systems HIPPS High Integrity Pressure Protection Systems HIPPS HIPPS > High Integrity Pressure Protection Systems WHAT IS A HIPPS The High Integrity Pressure Protection Systems (HIPPS) is a mechanical and electrical

More information

RELIEF VALVES IN PARALLEL

RELIEF VALVES IN PARALLEL RELIEF VALVES IN PARALLEL Mary Kay O'Connor Process Safety Center International Symposium BEYOND REGULATORY COMPLIANCE MAKING SAFETY SECOND NATURE October 26-28, 2010 James R. Lawrence Sr. Why use a Relief

More information

Bespoke Hydraulic Manifold Assembly

Bespoke Hydraulic Manifold Assembly SIL SM.0003 1 Bespoke Hydraulic Manifold Assembly Compiled By : G. Elliott, Date: 12/17/2015 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic Data Sheet T 8389 EN Series 3730 and 3731 Types 3730-2, 3730-3, 3730-4, 3730-5 and Type 3731-3 Electropneumatic Positioners EXPERTplus Valve Diagnostic Application Positioner firmware to detect potential

More information

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No Page 1 of 8 CALIBRATION SYSTEM REQUIREMENTS ESCC Basic Specification Issue 4 February 2014 Document Custodian: European Space Agency see https://escies.org PAGE 2 LEGAL DISCLAIMER AND COPYRIGHT European

More information

American made since 1954

American made since 1954 Hampden Engineering Corporation LOOK TO HAMPDEN FOR YOUR TRAINING NEEDS! Hampden s selection of Instrumentation and Process Control Training equipment is far larger than we are able to show you in this

More information

Safety-Critical Systems

Safety-Critical Systems Software Testing & Analysis (F22ST3) Safety-Critical Systems Andrew Ireland School of Mathematical and Computer Science Heriot-Watt University Edinburgh Software Testing & Analysis (F22ST3) 2 What Are

More information

SPR - Pneumatic Spool Valve

SPR - Pneumatic Spool Valve SIL SM.008 Rev 7 SPR - Pneumatic Spool Valve Compiled By : G. Elliott, Date: 31/08/17 Contents Terminology Definitions:... 3 Acronyms & Abbreviations:... 4 1.0 Introduction... 5 1.1 Purpose & Scope...

More information

The impact of different means of transport on the operation and maintenance strategy for offshore wind farms

The impact of different means of transport on the operation and maintenance strategy for offshore wind farms The impact of different means of transport on the operation and maintenance strategy for offshore wind farms W.A.A.M. Bierbooms, M Sc.; G.J.W. van Bussel, PhD * Section Wind Energy, Faculty Civil Engineering

More information

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071 COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES Lamar Jones Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071 INTRODUCTION The purpose of this paper will be to compare a plug

More information

PROCEDURE. April 20, TOP dated 11/1/88

PROCEDURE. April 20, TOP dated 11/1/88 Subject: Effective Date: page 1 of 2 Initiated by: Failure Modes and Effects Analysis April 20, 1999 Supersedes: TOP 22.019 dated 11/1/88 Head, Engineering and Technical Infrastructure Approved: Director

More information

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017 HS Bubbler Technology HyQuest Solutions New Zealand User Group August 2017 Origins of Gas Purge Technology 1940 s - Developed By Dutch Engineer Late 1940 s 1954 - Adopted by State of Illinois Water Group

More information

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x Electrical Installation Requirements Care should be taken to separate the power and signal cables to prevent electrical interference and possible damage due to inadvertent connection. SUPPLY E L N LN2

More information

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Health and Safety Executive Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Background Accidents involving

More information

Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants

Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants Tahir Rafique Lead Electrical and Instruments Engineer: Qenos Botany Site Douglas Lloyd Senior Electrical

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

Improving distillation tower operation

Improving distillation tower operation Improving distillation tower operation Measuring differential pressure across long sections of distillation columns has always been challenging, but purpose-built sensor systems provide a solution Fast

More information

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions SIL SM.015 Rev 0 Eutectic Plug Valve Compiled By : G. Elliott, Date: 19/10/2016 Contents Terminology Definitions......3 Acronyms & Abbreviations...4 1. Introduction..5 1.1 Scope 5 1.2 Relevant Standards

More information

Application Notes. Aluminium Electrolytic Capacitors

Application Notes. Aluminium Electrolytic Capacitors Application Notes Aluminium Electrolytic Capacitors , now part of the Evox Rifa Group, is one of Europe s leading manufacturers of Large Can Aluminium Capacitors. The Evox Rifa Group is a major global

More information

The Best Use of Lockout/Tagout and Control Reliable Circuits

The Best Use of Lockout/Tagout and Control Reliable Circuits Session No. 565 The Best Use of Lockout/Tagout and Control Reliable Circuits Introduction L. Tyson Ross, P.E., C.S.P. Principal LJB Inc. Dayton, Ohio Anyone involved in the design, installation, operation,

More information