1 RJE International August 3, TAC-300 Revision C COMBAT SWIM BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International, Inc Barranca Pwky, Ste I-112, CA Ph: (949) Fax: (949) sales@rjeint.com Website: rjeint.com TAC-300 Revision C
2 WARNING READ THIS BEFORE USING THE TAC-300.The TAC-300 default setting is to measure depth in feet (Imperial). To display depth in meters (Metric), please follow instructions on page 11. Ensure that the DG101 is properly set to measure in feet or meters before diving. WARNING Diving is a dangerous and potenally life threatening acvity. The TAC-300 combat swim board must be used by a person who is cerfied by a recognized agency (PADI, NAUI, SSI, NASDS, YMCA, etc.). Improper use or misuse of the TAC- 300 could result in serious injury or death. Do not use the TAC-300 or any of its components unl you have read and fully understand instruc- ons and safety precauons in this manual. Never rely on the TAC-300 as your sole means of underwater navigaon. Always have at least one other means of underwater navigaon 2014, RJE International, Inc. TAC-300 Diver Navigation Board Manual Rev C, Dated August TAC-300 Revision C Changing Depth Scale and MAX Alarm Level When the DG101 is connected to the battery charger, the unit can be toggled from displaying depth in FEET or METERS by long pressing the B Button. When the DG101 displays, the unit is measuring depth in feet while displaying MSW indicates meters. At this point DG101 will display or MSW with flashing MAX on the OLED display and 0 for depth. At this point, the operator must set MAX depth indicator levels. Short press the B Button to set the MAX Depth Alarm indicator by 10ft increments up to 200ft for. For the MSW setting, the increments are 3M up to 60M. Short pressing A Button to lock MAX depth limit. Remove the battery charger and re-install USB cap. Ensure that the cap is properly installed to prevent flooding the unit. Note: DG101 will also display warning to reinsert USB cap before diving. To clear warning, short press A-Button. TAC-300 SPECIFICATIONS Board & Compass Material HDPE Plastic Size 7.0 x x 3 (18cm x 26cm x 7.5cm) Unit Weight 2.7lbs (1.2Kg) Compass Illumination 6 hours TAC-LITE Operational Life 120 hours Digital Depth Gauge/Timer Depth Range 0-330ft (0-100m) Depth Tolerance +/- 1% of Full Scale Depth Resolution 0.1ft/0.1m Display Red OLED Display Dive Timer Tolerance ± 1% Leg Timer Functions Start / Pause / Reset Led Timer Duration 99 hours max Battery Rechargeable Lithium Polymer Battery Life 300 charges Operational Life 20 hours Operating Temperature 29 F - 95 F (-2 C - 42 C) Housing Aluminum with Injected molded plastic Depth Rated 330ft (100m) TAC-300 SPARES LIST TAC300-3 TAC-LITE TAC300-4 Carrying Bag TAC300-1 Underwater Compass DG101 Digital Depth Gauge/Timer Module DG100-1 Battery Charger for DG101 TAC-CHRON Chronometer TAC-300 Revision C 11
3 When re-installing the DG101, line the top slot of the unit with the top of the clip and slip the tap of the clip into the slot. Gently press the DG101 into the clip while forcing the bottom of the clip away from the housing of the DG101 until it clip slips into place. Pull on the DG101 to ensure that the unit is secure on the board. Battery Charging The battery on the DG101 is a Lithium Ion and can be charged over 300 times to provide over 10,500 hours of dive time. The battery is sealed in the unit and functions just like a cell phone battery. A USB connector in the back of the unit provides access for the battery charger. To charge the DG101, remove the battery charge cap from the back of the unit by turning it counter clockwise until the slots line up. Use a flat object to lift the cap from the body of the DG101. Remove cap with flat object Insert USB connector into charging receptacle Plug USB connector from DG101 Battery Charger (DG101-01) into the back of the DG101 and then plug the charger into a 110/220 volt outlet. Note that the battery health indicator will start to flash. The DG101 will charge to 90% in 2 to 3 hours and to 100% in 12 hours. Once unit has completed charging, remove USB Connector and re-install USB cap. Ensure that the cap is properly installed to prevent flooding the unit. The DG101 will display a blinking warning to re-insert USB cap before diving. To clear warning short press the A Button. NOTE: If after completing the charging cycle the unit fails to activate, follow the rebooting process to active the DG101.(see below) Rebooting the Unit If the battery Health Indicator falls below zero percent or if the unit is stored for too long, the DG101 will revert to a hibernation mode to protect the battery. To wake up the DG101, the unit needs to be rebooted. Place the unit on battery charge for at least three hours. While keeping the unit connected to the battery charger, press and hold A and B button at the same time for ten(10) seconds. Release A and B buttons and then remove the USB connector for the back of the unit. Now short press the A button to activate the unit. The DG101 is now ready for use. Complete the charging process as necessary. Note: DG101 will also display warning to re-insert USB cap before diving. To clear warning, short press A-Button. 10 TAC-300 Revision C PROPERTY PREFACE The information, descriptions, photos, and illustrations in this manual are the property of RJE International, Inc. Materials may not be reproduced or disseminated without prior written consent of RJE International, Inc. WARRANTY RJE International, Inc. warrants the TAC-300 to be free of defects in material and workmanship for a period of one year from date of delivery to the original purchaser. Obligation under this warranty is limited to repair or, at the sole discretion of RJE International, replacement of any product returned to our facility or authorized distributor. All products shall be shipped to RJE FREIGHT PREPAID and shall be returned to customer FREIGHT COLLECT. Equipment may not be returned without prior authorization which must be requested in writing, or phone call. Upon authorization a Case Number will be issued. The Case Number must appear on the outside of the shipment, as well as, in all pertaining correspondence. Shipments received without a Case number will be refused by RJE International. This warranty does not apply in cases where the product malfunctions as a result of mishandling or improper use. LIABILITY RJE International, Inc. assumes no liability for damages, losses, or cost incurred consequentially through operation or malfunction of any RJE International, Inc. product. CHANGES RJE International Inc. reserves the right to make changes in design or specifications at any time without any obligation to modify previous units. This manual is provided for information and reference purpose only and is subject to change without notice. We always welcome our customers feedback and product improvement ideas. If you have any questions or comments, contact us at: RJE International, Inc Barranca Pwky, Ste I-112, CA Ph: (949) Fax: (949) sales@rjeint.com Website: rjeint.com TAC-300 Revision C 3
4 INTRODUCTION The TAC-300 combat swim board was developed and is used by divers for accurately navigating underwater. Highly reliable and rugged, the TAC-300 consist of four major components: a rugged high impact plastic board, a large underwater compass, a digital depth gauge with timer and a chronometer. The TAC- 300 is supplied with a cord lanyard with clip and protective sock. The board comes in a padded carrying case. The TAC-300 allows the diver to monitor depth, direction and leg time. By using this information, a diver can plot and follow a planned course during a dive with a high level of reliability. TAC-CHRON Chronometer TAC-LITE Holder DG101 Digital Depth Gage with Timer TAC300-1 Compass TAC-300 Combat Swim Board 4 TAC-300 Revision C Stopwatch Mode While in Dive or Surface Mode, Short-Press the A and B Button together to access Stopwatch Mode. A small icon will appear in the right corner of the display. This mode allows the operator to start the timer, pause it, restart, and reset to zero. Once started, short press the B Button to start and pause the timer. Short press A Button to zero the timer. Pressing the A and B Button together the unit back to dive time or surface interval time (stopwatch icon will disappear). Battery Health Indicator The DG101 comes with a rechargeable battery that provides up to 35 hours of continuous use. Upon activation, the battery health indicator is located on the top-left of the display and looks like a battery. When fully charged the battery is full (see below). It is recommended you check the battery level before every dive. 100% 50% 25% Maintenance The DG101 is designed to need very little maintenance to meet its functional requirements. Although built for the rigors of underwater use, the DG101 is a precision instrument and should be treated as such. Avoid violent bumps and drops that could effect the pressure transducer and reliability of the gauge. Do not exceed the maximum depth of 330ft (100M) as this may damage the unit. Use mild soap and rinse with fresh water after every use. The DG101 battery has a shelf-life of 3 months when fully charged. When storing for a long periods of time, it is recommend that the unit be fully charged to avoid going into hibernation. Also store in a cool and dry location. The DG101 is held onto the TAC-300 board by a metal clip. To remove the DG101, place a flat tool between the bottom of clip and the gauge, were the buttons are, and gently force the clip away from the housing of the DG-101. Now pull the unit free of the clip. TAC-300 Revision C 9
5 Using the DG101 Activation and De-activation of the unit The DG101 will enter Dive Mode automatically once immersed in water to a depth of approximately 3 feet (1 meter). NOTE: The DG101 cannot be please in hibernation while in Dive Mode. While in Surface Mode you can activate the unit by Short Press either A or B button. While in Surface Mode you can place the DG101 into hibernation by Long Press the A button. After being in Surface Mode for 10 minutes the unit will automatically enter Hibernation Mode 0.0 Monitoring Depth Once in Dive Mode the DG101 will continually display the depth in real time to 330ft (100m). The depth will be displayed in (feet-of-seawater) or MSW (meters-of-seawater) based on the settings. The display will indicate or MSW to represent the proper setting. NOTE: Please note this setting when planning your dive. During the dive, the operator can toggle between the current dive and the maximum depth obtained during the dive by long pressing the B-Button. See Maintenance for changing depth scale. Max Dive Indicator The MAX Status will illuminate once the DG101 exceeds programed MAX depth. NOTE: The default setting for MAX depth is 30ft (9m). The MAX status remains on and can only be reset by re-entering Dive Mode from Surface Mode (new dive) or by attaching the DG101 to a USB port. See Maintenance for setting the Max Dive Indicator 2.2 MAX 0.0 Dive and Surface Timer Once the DG101 enters Dive Mode a timer starts to monitor the length of the dive on the top of the display in hours: minutes: seconds. The DG101 will stop monitoring the dive time once the unit is less than 3ft (1m) from the surface for more than 60 seconds. Once the unit has exceeded 60 seconds, it enters Surface Mode and displays surface time for up to 24 hours. The surface interval time will reset upon the next dive or when the timer exceeds 24 hours. 8 TAC-300 Revision C TAC-300 NAVIGATION BOARD The TAC-300 Navigation Board is a rugged high impact plastic board that is the base for the board s instruments. The TAC300-1 Underwater Compass, TAC-CHRON and the DG101 are mounted onto the board to complete the system. The hardware used to mount the compass is made out of non-corrosive material and should provide you with many years of service. The TAC-300 board uses a electronic the TAC300-3 TAC-LITE to illuminate the compass. To activate the TAC-LITE, momentary press and release the button. The TAC-LITE has three position, OFF, LOW, and HIGH Battery Button To install the TAC-LITE, slide the tapered end into the bottom-front holder. Ensure the activation button is facing down. This will allow you access to the button. The TAC-LITE operates for up to 120 hours of continuous use. Use a small flat screwdriver to remove the TAC-LITE when needed. TAC300-1 UNDERWATER COMPASS The TAC300-1 Underwater Compass is designed and manufactured for the rigors of underwater use. A black compass card with luminous heading markers allows you to maintain a course heading, even in the worst visibility for up to six hours. Illuminating the compass can be achieved by shining a bright light or UV light on the compass card for several minutes. TAC-300 Revision C 5
6 TAC-CHRON Dive Chronometer The purpose of the TAC-CHRON, used on the TAC-300 navigation board, is to track leg time for navigation and also track the total dive time. The TAC-CHRON is a rugged and reliable dive chronometer with electroluminescent back lighting. Functions A = See Modes Below B = See Modes Below C = Press to change from mode to mode D = To activate the backlight Modes C = Press button to move from one mode to another. See flow below. Setting Time and Date Press A in the timekeeping mode. The seconds digits flash on the display because they are selected. Press C to change the selection in the following sequence: To reset the seconds to zero (00), press E when seconds is flashing. To set hour, minutes, month, date, and day of week press C until they flash and then E to increase the number or B to decrease the number. To return to the timekeeping mode press A Stopwatch Mode The stopwatch mode allows you to measure elapsed time for up to 23 hours and 59 minutes. Press E to start the stopwatch Press E to pause stopwatch Press E to resume stopwatch Press A to reset stopwatch 6 TAC-300 Revision C DG101 Digital Depth Gauge/Timer Module The DG101 is a digital depth gauge that measures and displays depth accurately from 0 to 330Ft (0-100m) resolution is 0.1ft (0.1m). The DG101 also functions as a bottom timer, surface interval timer, and has a separate stop- watch feature. These features are available once the unit is activated. The DG101 operates in three modes, Dive Mode, Surface Mode and Hibernation Mode. These modes are independent of each other even though that share some of the same functions. Once the DG101 is immersed in water and senses depth of 3 feet (1 meter) it activates and enters Dive Mode. In this mode the DG101 operates as a depth gauge, tracks your dive time, allows access to the stop-watch mode, and several safety functions. Once in the Dive Mode the DG101 cannot be de-activated. When ascending to the surface, if the DG101 senses a depth of 3ft (1 meter) or less for 60 seconds it will enter Surface Mode. In this mode the DG101 tracks surface intervals up to 24 hours. While in Surface Mode the DG101 memory can be accessed and allows the diver to recall their deepest excursion and display it. When recalling the max depth, the total dive time is also displayed. After 10 minutes on the surface, the DG101 will enter Hibernation Mode and shuts down. Please note the unit is not powered off but hibernating. Always check battery level before a dive. The DG101 can be put into Hibernation Mode or woken up by pushing the function buttons. Battery Level Leg/Dive/Surface Timer Depth 0.0 MAX Stopwatch Indicator Depth Warning Metric/Imperial Indicator A Button B Button DISPLAY STATUS INDICATOR: MAX = Maximum Depth = Feet of Sea Water MSW = Meters of Sea Water Depth readings and stopwatch/dive/surface times are provided through a large Red OLED display. The DG101 buttons supply access to these functions. An ambient light sensor automatically adjusts brightness of the display. All functions of the DG101 are controlled through buttons on each side of the display. Buttons are operated in two modes Short Press or Long Press. The Short Press is the quick press and release of the button to access a desired function. A Long Press is defined as pressing the button for 2 second or longer before release. TAC-300 Revision C 7
COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4
COMBAT SWIM BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International January 16, 2017 RJE International, Inc. 15375 Barranca Pkwy, Ste. I-112,
More informationCOMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6
COMBAT SWIM BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International Feb 1, 2017 12 TAC-300 Revision 6 RJE International, Inc. 15375 Barranca
More informationDIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10
DIVER NAVIGATION BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International Feb 1, 2017 12 TAC-100D Revision 10 RJE International, Inc. 15375 Barranca
More informationDIVER NAVIGATION BOARD
RJE International, October 20, 2010 12 TAC-200A Revision 3 DIVER NAVIGATION BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International, Inc. 15375
More informationTAC-100A DIVER NAVIGATION BOARD OPERATIONS MANUAL. RJE International, Inc. RJE International, October 20, TAC-100A Revision 3
TAC-100A DIVER NAVIGATION BOARD OPERATIONS MANUAL RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International, October 20, 2010 12 TAC-100A Revision 3
More informationDIVER NAVIGATION BOARD
RJE International, May 14, 2015 12 TAC-100A Revision 4 DIVER NAVIGATION BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International, Inc. 15375
More informationDG100 Digital Depth Gauge and Timer. Training Module, Rev B
DG100 Digital Depth Gauge and Timer Training Module, Rev B DG100 Digital Depth Gauge Dive and Surface Timer Stopwatch Mode Designed for Military Divers Combat Swimmers DG100 Used as a Replacement for Analog
More informationRJE INTERNATIONAL, INC.
RJE INTERNATIONAL, INC. D TI-300A D IVER A C OUSTIC R ECEIVER U SER MANUAL R EV 3.0 1 0 / 2 7 / 2 0 1 7 600-1 7 0 0 3 Forward This manual is comprised of figures and text intended to provide descriptions
More informationAA GWR Water Retention Meter for Accurate Measurement of Water Retention
AA GWR Water Retention Meter for Accurate Measurement of Water Retention Principle of Measurement: Coating color is poured into a test cell and separated from a blotting paper with a filter. The cell is
More informationAA100 Acoustic Actuator
AA100 Acoustic Actuator Operating Manual REV. A, September 2001 COPYRIGHT 2001. ALL RIGHTS RESERVED Return Procedure It is necessary to obtain from ORE Offshore a Returned Material Evaluation (RMA) number
More informationSmart Apnea Computer. Instruction Manual
Instruction Manual Smart Apnea Computer Smart Apnea Computer TABLE OF CONTENTS 1. INTRODUCTION 3 1.1. OPERATING MODES 3 1.2. USER-REPLACEABLE BATTERY 3 1.3. CONNECTING SMART APNEA TO A PC OR MAC 3 1.4.
More informationBante820 Portable Dissolved Oxygen Meter Instruction Manual
Bante820 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante820 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante820 portable dissolved oxygen
More informationCalibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.
Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up
More informationACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH
ACCUSTRIDE Digital Clip-on Pedometer WC153 ACCUSTRIDEFM Digital Clip-on Pedometer WC154 ENGLISH CONTENTS INTRODUCTION USE OF PEDOMETER 4 BASIC FEATURE 5 TIME MODE 7 WALK / RUN MODE 9 MEMORY MODE 11 USER
More informationECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark
ECHO MANUAL L B A ltim e te rs ECHO is a trademark of LB Altimeters, Denmark LB Altimeters operates a policy of continuous development Therefore, we reserve the right to make changes and improvements to
More informationSUUNTO ELEMENTUM AQUA USER GUIDE
SUUNTO ELEMENTUM AQUA USER GUIDE en A B SETTINGS MEMORY DIVE TIME Functions: _Time, date, alarm _Backlight _Auto dive mode _Depth, max. depth _Dive time _Surface time _Water temperature _Number of dives
More informationMODEL 100 NITROGEN INFLATION CART
MODEL 100 NITROGEN INFLATION CART Installation & Operation Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV120106 P/N: 81-0113 TABLE OF CONTENTS SAFETY
More informationPedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX
OVERVIEW FRONT VIEW Pedometer with PC download INDEX Model: FB322 Introduction...1 Overview...1 Front view...1 Back view battery compartment...1 LCD screen...1 Getting started...2 Setting the device...2
More informationNEULOG OXYGEN LOGGER SENSOR GUIDE
NeuLog oxygen logger sensor NUL-205 The oxygen sensor can be used for any science experiment or activity where oxygen levels, dissolved or gaseous, are required. Some fields of study include Chemistry,
More informationSC-888 Instructions. The following illustration provides the operation of pushbuttons and location of indicators for the Robic SC-888.
1 05/04/05 SC-888 Instructions Thank you for buying the Robic SC-888. Your purchase brings you a world class timer with a vast array of advanced timekeeping functions. Please take a moment to review this
More informationMatrix Dive Computer. Instruction Manual
Instruction Manual Matrix Dive Computer MATRIX Dive Computer TABLE OF CONTENTS 1 Introduction 3 1.1 Glossary 3 1.2 OPERATING MODES 4 1.3 Rechargeable battery 4 1.3.1 CHARGING THE BATTERY 4 1.3.2 CONNECTING
More informationBante821 Portable Dissolved Oxygen Meter Instruction Manual
Bante821 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante821 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante821 portable dissolved oxygen
More information6 digital caliper with case
6 digital caliper with case Model 98563 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly
More informationWELCOME TO THE REVOLUTION
USER GUIDE WELCOME TO THE REVOLUTION THANK YOU FOR CHOOSING THE GCQUAD We listened to what you wanted - and created the most accurate, versatile and game-enhancing ball and club analysis solution available
More informationWATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL
WATCH COLLECTION NG701 SERIES INSTRUCTION MANUAL INTRODUCTION This watch features electronic sensors that measure outdoor conditions such as temperature, pressure, and altitude. The watch provides essential
More informationOPERATING INSTRUCTIONS V 5.3
1 OPERATING INSTRUCTIONS V 5.3 DM 06/ 07 EGO 06/ 07 ION /SP8 MINI Proto Matrix 07 Proto Rail Shocker Seventh Element, Inc WARNING Failure to follow directions may result in damage to board. Do not pull
More informationOperation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17
Operation Manual Pro He Alarm TM Helium Analyzer Rev 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044
More informationUser's Manual. Heavy Duty Dissolved Oxygen Meter. Model
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More informationIn Vivo Scientific, LLC INSTRUCTION MANUAL
CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3
More informationAltimeter and Compass Watch Instruction Manual
Altimeter and Compass Watch Instruction Manual Overview Figure 1 LCD display description Features Hour, minute, second, year, Auto calendar 12/24 hour format display month, day, day of week Daily alarm
More informationGasLab SAN-102 Micro Oxygen Monitor User Manual
GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined
More informationUnderwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80
Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80 Product Number 6170.60 Product Registration Please register your product at ikelite.com within 15 days of purchase. Our product registration database
More informationDT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS
DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS Overview:--- Positive or Negative Icon Barometric Trend Indicator SELECT Low Battery Indicator AM/FM Indicator Daily Alarm Indicator
More informationField 1. Barometer Alarm Symbol. Field 2. Barometer Trend Indicator. Altimeter/Barometer Alarm Symbol Field 4. Altimeter Function Indicator
EN Escape203 Barometer Alarm Symbol Barometer Trend Indicator Field 1 Field 2 Altimeter/Barometer Alarm Symbol Field 4 Low Battery Warning Field 3 Mode Indicator [-] -Button Altimeter Function Indicator
More informationSPECIFICATIONS APCEPH1
APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x
More informationF11 OPERATING MANUAL F11 OPERATING MANUAL
F11 OPERATING MANUAL 2002 Design, 2014 1 CONTENTS NOTICES...2 INITIAL ACTIVATION...3 FULL LCD...3 GENERAL FEATURES & DISPLAYS...5 INTERACTIVE CONTROL CONSOLE...6 OPERATING MODE STRUCTURE...6 OPERATION
More informationCONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output
CONSOLE-320 Item 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output Table of contents 1. INTRODUCTION...2 1.1 Power supply...2 1.2 Connections...2 1.3
More informationCircuFlow Quick Setup Guide
CircuFlow 5200 Quick Setup Guide LB04.0001 Rev B 20140314 TABLE OF CONTENTS Setup Therapy Setup Gradient Mode Pressure Mode Lock Device Unlock Device Treatment 03 04 05 08 11 12 13 02 SETUP 01 01 Open
More informationGetting to know your Sureshotgps micro V3
Getting to know your Sureshotgps micro V3 Battery State Symbol Satellite Signal Shows distance to front, centre and rear of each green Hole Number Real Time Power on and Enter Key Down (backward) Key 1
More informationSMART Oxygen Analyzer. User Manual
SMART Oxygen Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 NITROXBUDDY2 OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 3 6 SETTINGS... 4 6.1 BUTTON... 4 6.2 DISPLAY...
More informationSampling Equipment Catalog. MicroPurge Low-Flow Pump Control
MicroPurge Low-Flow Pump Control Sampling Equipment Catalog 10 MicroPurge Controls The MicroPurge Controller (U.S. Patent Number 6,508,310) revolutionizes low-flow sampling with advanced logic control
More informationINSTRUCTION MANUAL. P330A 3D Pedometer LAYOUT FEATURES. VIDEO INSTRUCTIONS:
INSTRUCTION MANUAL P330A 3D Pedometer VIDEO INSTRUCTIONS: www.csxpro.com/p330a LAYOUT 1. LCD display 2. SET Button 3. Metal Pin 4. Battery Case 5. Holes on Wristband 6. Loop Hole FEATURES PEDOMETER 3D
More informationOcean Technology Systems ComBox
Undersea Systems International, Inc. dba Ocean Technology Systems ComBox Silver Bullet User s Guide Technology in Depth - NOTICE - This manual and the information contained herein are provided for use
More informationAladin ONE (Matrix) User Manual
Aladin ONE (Matrix) User Manual ALADIN ONE DIVING COMPUTER - DESIGNED BY DIVING ENGINEERS Welcome to SCUBAPRO dive computers and thank you for purchasing the Aladin One. You are now the owner of an extraordinary
More informationTrekMill USER'S MANUAL MM5050
Read the safety and comfort guide in this manual before using this equipment. USER'S MANUAL TrekMill MM5050 Serial Number: Date Purchased: Find the serial number in the location shown below. CONTENTS Safety
More informationCDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin
Electronic Control Manual 216 Sensors and Stats Section S Technical Bulletin CDS-2000 Issue Date 0393 CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin Introduction 3 Pre-Verification
More informationUnderwater Housing for Canon G7X Mark II
Underwater Housing for Canon G7X Mark II Product Number 6146.08 Product Registration Please register your product at ikelite.com within 15 days of purchase. Our product registration database is the best
More informationThe Univentor 1250 Anaesthesia Unit
THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2
More informationUser Manual GRI- 1500Li
User Manual GRI- 1500Li Your Cart Tek caddy cart was thoroughly quality control checked and road tested before being shipped to your address. We do everything possible to assure that your caddy is in perfect
More informationGasLab SAN-102 Micro Oxygen Monitor User Manual
GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined
More informationPRO PLUS 2. dive computer. operating manual
PRO PLUS 2 dive computer operating manual LIMITED TWO-YEAR WARRANTY For details, refer to the Product Warranty Registration Card provided. COPYRIGHT NOTICE This operating manual is copyrighted, all rights
More information1.0 General Guide WARNING!
User Manual 1.0 General Guide Thank you for purchasing your new ADC. We recommend reading this manual, and practicing the operations before using your ADC in the field. The ADC is designed to provide you
More informationPS-425 Pitot-Static/Air Data Tester
PS-425 Pitot-Static/Air Data Tester OPERATION AND MAINTENANCE MANUAL Preston Pressure LLC 580-286-3161 prestonpressure.com Revision 1, February 16, 2011 PRESTON PRESSURE LLC PS-425 USER AND MAINTENANCE
More informationWELCOME This QuickStart Guide will help you to understand the basic surface and underwater operation of the Oceanic DataMask. Prior to diving with the DataMask, you must also read and understand both the
More informationVeo 200/250 dive computers operating manual
OCEANIC Veo 200/250 dive computers operating manual LIMITED TWO-YEAR WARRANTY For details, refer to the Product Warranty Registration Card provided. COPYRIGHT NOTICE This operating manual is copyrighted,
More informationSMART Carbon Monoxide Analyzer. User Manual
SMART Carbon Monoxide Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 MONOX OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 3 6 SETTINGS... 4 6.1 BUTTON... 4 6.2 DISPLAY...
More informationTWO YEAR LIMITED WARRANTY
TWO YEAR LIMITED WARRANTY Betsey Johnson time pieces have a two year limited warranty from date of original purchase. This warranty covers all manufacturers defects in material and workmanship. The warranty
More informationOutbreaker Sailor Compass / Outbreaker Sailor Compass Medium Model: RA202 / RA282 User Manual TABLE OF CONTENTS
Outbreaker Sailor Compass / Outbreaker Sailor Compass Medium Model: RA202 / RA282 User Manual TABLE OF CONTENTS Introduction... 2 Key Features... 3 Watch... 3 LCD Display... 4 Getting Started... 4 Unpack
More informationRAM 4021 Operation Manual
RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6
More informationBante810 Benchtop Dissolved Oxygen Meter Instruction Manual
Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen
More informationColor Dive Computer. Instruction Manual
Instruction Manual Color Dive Computer Icon HD Dive Computer TABLE OF CONTENTS ICON HD 3 CHARACTERISTICS OF ICON HD 3 IMPORTANT WARNINGS 3 RESPONSIBLE DIVING PRACTICES 3 HOW ICON HD WORKS 4 DURING THE
More informationDOscan10 Pocket Dissolved Oxygen Tester Instruction Manual
DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual BANTE INSTRUMENTS CO., LTD DOscan10 Pocket Dissolved Oxygen Tester 1 Thank you for selecting the DOscan10 pocket dissolved oxygen tester. This
More informationDPC-30 DPC-100. Reference Manual
DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,
More informationSmart Dive Computer. Instruction Manual
Instruction Manual Smart Dive Computer Smart Dive Computer TABLE OF CONTENTS IMPORTANT WARNINGS 3 DISCLAIMER 3 1. INTRODUCTION 3 1.1. GLOSSARY 3 1.2. OPERATING MODES 4 1.3. USER-REPLACEABLE BATTERY 4 1.4.
More informationVers Gas Generator. Release III INSTRUCTION MANUAL. Advanced Calibration Designs, Inc.
Advanced Calibration Designs, Inc. Vers ersacal Gas Generator Release III Advanced Calibration Designs, Inc. 2024 W. McMillan Street Tucson, Arizona 85705 U.S.A. Telephone: (520) 290-2855 Fax: (520) 290-2860
More informationOwner s Manual Humiport 10/20
4201 Lien Rd Madison, WI 53704 Owner s Manual Humiport 10/20 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Humiport line of ThermoHygrometers offers the restoration
More informationINSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC
Electronic Baseball Pitching Machine baseball INSTRUCTION MANUAL PART NO. B-EHABA-100 REV022111 INSTRUCTION MANUAL Includes: OPERATION SETUP USE & CARE SERVICE SPORTS ATTACK LLC 800-717-4251 www.sportsattack.com
More informationOperation Manual. Pro CO. Carbon Monoxide Analyzer. Rev
Operation Manual Pro CO Carbon Monoxide Analyzer Rev. 10.17 Quick Reference Guide READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display powers up. 2. To turn off, hold
More informationMODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual
UNITEC MANUFACTURING DIVISION MODEL 9875 STADIUM BASEBALL SCOREBOARD (WITH INNING BY INNING SCORING) Instruction Manual Mailing Address: PO Box 260, Yorkville, NY 13495-0260 Plant Address: 34 Main Street,
More informationSEEMANN XP 5 OWNER`S GUIDE
SEEMANN XP 5 OWNER`S GUIDE LIMITED TWO-YEAR WARRANTY For details, refer to the Product Warranty Registration Card provided. COPYRIGHT NOTICE This owner s guide is copyrighted, all rights are reserved.
More informationTABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6
TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6 CURRENT TIME MODE 7 FUNCTIONAL DISPLAY 7 WEATHER FORECAST FEATURE
More informationOperation Manual. Pro CO O 2 Alarm. Carbon Monoxide and Oxygen Analyzer. Rev
Operation Manual Pro CO O 2 Alarm Carbon Monoxide and Oxygen Analyzer Rev. 08.17 Quick Reference Guide for CO Analyzer READ ENTIRE MANUAL BEFORE USE 1. To switch on, hold the On/Off button until the display
More information35 Watt LED. Lighting System USER MANUAL. January 2019 Rev A
35 Watt LED Lighting System USER MANUAL January 2019 Rev A This is the user manual for the Dive Rite EX35 Lighting System. This user manual is proprietary and copyright Lamartek, Inc. 2019. It may not
More informationPM105 PRESSURE METER USER S MANUAL
PM105 PRESSURE METER USER S MANUAL Manual revision: 15 March, 2001 SCSMANP015 Copyrighted 2001 Thank you for purchasing a Tek Know pressure meter. The Tek Know products are manufactured by Scan-Sense AS
More informationDate of Purchase
NiTek Trio Dive Computer User Guide www.diverite.com Date of Purchase Content DEVELOPED BY COPYRIGHT NOTICE WARRANTY INFORMATION Dive Rite 175 NW Washington Street Lake City, FL 32055 Phone: 386.752.1087
More informationGETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP
GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by
More informationINSTRUCTION MANUAL D Pedometer with Clip. VIDEO INSTRUCTIONS:
INSTRUCTION MANUAL 341 3D Pedometer with Clip VIDEO INSTRUCTIONS: www.csxpro.com/341 1. FUNCTION 1. LCD Display 6. System RESET Button 2. MODE Button 7. Battery Cover 3. SET Button 8. Lanyard Hole 4. RESET
More informationGE Measurement & Control
GE Measurement & Control Psyclone Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. C August 2013 Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses
More informationGRI-1300/1350Li. User Manual
User Manual GRI-1300/1350Li Your Cart Tek caddy cart was thoroughly quality control checked and road tested before being shipped to your address. We do everything possible to assure that your caddy is
More informationNOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL
NOVALYNX CORPORATION MODEL 260-2595 RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL REVISION DATE: August 2018 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify NovaLynx
More informationOXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:
OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle
More informationMETEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions
METEOR LSR36500 UNDERWATER POOL LIGHT Operating Instructions LIGHTING CONTENTS Preface...3 Features...3 Precautions...3 Components and Connectors...4 Installation...5 Controls...7 Appearance...8 Technical
More informationCopyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic
Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission
More informationNB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com
More informationSweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.
MAGUIRE PRODUCTS INC. SW SERIES SWEEPERS For SW Series Sweeper Models: SW-4815 SW-4820 SW-4825 Sweeper Dual Control Automatic Sweeper Switching System INSTRUCTION AND OPERATION MANUAL Copyright Maguire
More informationINSTRUCTIONS warranty watch care
INSTRUCTIONS warranty watch care Congratulations on the purchase of your Szanto timepiece! Please read and follow the watch care instructions carefully to ensure that you are able to enjoy your timepiece
More informationPsyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)
GE Sensing Psyclone TM Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. A (September 2007) Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses
More informationMODEL CALIBRATION GAS DELIVERY SYSTEM
MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This
More information! Warning, refer to accompanying documents.
About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument
More informationWireless Belt Pack BP Conductor with Radio Transmit
Wireless Belt Pack BP5-10 5-Conductor with Radio Transmit Operation Manual 7340 SW Durham Road Portland, OR 97224 USA Phone: 503-684-6647 1-800-527-0555 Fax: 503-620-2943 email: sales@firecom.com www.firecom.com
More informationManufactured by: AAA
Manufactured by: AAA The Altitron Skydiving Altimeter is an advanced digital altimeter. It is designed to effectively improve safety and easily keep track of skydiving activity. It can be used as a mechanical
More informationGolf Performance Monitors. PureContact Operating Guide. Version of 9
PureContact Operating Guide Version 5.1 www.zelocity.com 1 of 9 PureContact Metrics: Measured Ball Velocity Carry Distance Other PureContact Features: Instantly, Accurately Displays & Records Critical
More informationOPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051
NOT SCALE / IF IN DOUBT ASK* DIVE CALIPER OPERATION MANUAL *THIS INFORMATION IS THE PROPERTY OF ZEBRA-TECH LTD. ALL RIGHTS RESERVED.* *ALL UNITS IN MM/DEGREES UNLESS SPECIF SURFACE F 3.2 Ra UNLESS S Part
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationNew product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package
New product release Closed Circuit Research is pleased to announce the launch of our range of Universal Rebreather Monitors Key features and benefits include: Universal Rebreather Monitor (URBM) Single
More informationAladin TEC 3G User manual
Aladin TEC 3G User manual SAFETY CONSIDERATIONS You must carefully read and understand this entire manual before using your Scubapro Aladin TEC 3G. Diving has many inherent risks. Even if you follow the
More informationUSER MANUAL
C Cimarron Sports 1-888-816-6517 www.cimarronsports.com Combo Pitching Machine USER MANUAL TABLE OF CONTENTS Thank you for purchasing the Cimarron Combo Pitching Machine. The Cimarron Combo Pitching Machine
More informationStockWeigh 500 D3632 US-B
OPERATORS MANUAL DIGI-STAR 790 WEST ROCKWELL AVENUE FORT ATKINSON, WISCONSIN 53538 PHONE: (920) 563-1400 TECHNICAL SERVICE: 1-800-225-7695 (920) 563-9700 D3632 US- Rev. B August 4, 2004 StockWeigh 500
More informationALLTAB 2.0. User Instructions. Military & Professional model (MilPro) Maximum operating depth for Alltab 2.0 (MilPro) is 150 meters / 492 feet
ALLTAB 2.0 Military & Professional model (MilPro) User Instructions Maximum operating depth for Alltab 2.0 (MilPro) is 150 meters / 492 feet Alltab User Instructions Alltab is a device that allows the
More informationMODEL CCX-AG CURVE STEP / CURVE STEP SYSTEM
To reduce the risk of drowning, entrapment, falls, paralysis, electrocution, or other serious injury or death: Dealer/Installer: Give manual to homeowner. Installer: Read "Safe Installation" on p. 2 and
More information