Compressed Air Conditioning Catalog Chapter I

Size: px
Start display at page:

Download "Compressed Air Conditioning Catalog Chapter I"

Transcription

1 Compressed Air Conditioning Catalog Chapter I

2 2 Compressed Air Conditioning Welcome Welcome New technologies and materials, design innovations and the integration of bus-suitable electronics have opened to our products more and more fields of application. In this way, we have continuously developed from the manufacturer of classic control systems based on pneumatics to a system supplier of electro-pneumatic and fully electronic engine controls. For either traditional or electronic systems, Rexroth Pneumatics offers the entire range of products.

3 Expertise Compressed Air Conditioning 3 Marine Components by Rexroth Pneumatics Ships have been cruising safely with pneumatic components by Rexroth Pneumatics for decades. They represent a powerful yet highly accurate means of controlling ship engines. Robust and reliable at the same time, they are still a preferred choice for low and medium speed diesel engines. Easy to maintain thanks to specific spare part kits, they are bound to have a long service life. maintenance/treatment A pneumatic system operates best when its medium, the compressed air, is conditioned appropriately. Rexroth Pneumatics offers a number of components fit to fulfill this key task perfectly: Anti-freezers Pressure regulators Filters Pressure reducing stations Certification We have committed to design and manufacture products which meet the highest quality standards. To keep that promise, our products must pass various tests such as endurance, EMV, vibration and salt mist. Pneumatic components by Rexroth Pneumatics are designed in accordance with the rules of Germanischer Lloyd. We design and manufacture in cooperation with:

4 4 Compressed Air Conditioning Index Index Antifreezer Antifreezer M22x1.5, 20 bar Page 06 Filter Line filter, 10 bar Page 07 Filter G 3/8, 30 bar Filter G 3/8, 30 bar (with clogging indicator) Page Filter, 40 bar Page 10 Filter G 1 1/2, 40 bar Page 11 Filter G 1, 40 bar Filter G 1/2, 40 bar Page Filter G 3/8, 50 bar Page 14

5 Index Compressed Air Conditioning 5 Index Pressure reducing stations Twin pressure reducing station with lever Page 15 Single pressure reducing station Page Pressure regulators Pressure regulator G 3/8, 30 bar Pressure regulator G 3/8 with manometer, 10 bar Page Pressure regulator G 1, 40 bar Pressure regulator G 1 1/2, 40 bar Page Pressure regulator M22x1.5 Page Oiler Oiler G 1/2, 16 bar Page 26

6 6 Compressed Air Conditioning Antifreezer M22x1.5, 20 bar Antifreezer M22x1.5, 20 bar Antifreezer Capacity of container Antifreezer -40 C to +80 C max. 20 bar Ethanol, fuel alcohol 200 cm³ 0.86 kg The antifreezer is designed for protecting the valves, piping and cylinders against freezing. s Symbol Input pressure Connection thread Antifreezer max. 20 bar M22 x Repair kit Assembly position vertically as drawn. Keep accessibility for parametrizing of device. 1) Winter position (at temperatures below 5 C), 2) Summer position, 3) Filling aperture dia. 11, 4) Operating instruction, 5) Drain screw.

7 Line filter, 10 bar Compressed Air Conditioning 7 Line filter, 10 bar Connection threads Flow direction Porosity Filter with condensate drain see table below see table below see table below Both way see table below 0.2 kg The line filter is designed to protect a pipe system against impurities. s Symbol Porosity Connection thread Operating pressure Line filter -50 C to +70 C µm for pipe 10x1 8 bar C to +80 C µm M22 x bar Repair kit for Repair kit for ) Assembly position is open. 1) Please provide additional space for dismounting the filter element. 2) without GL-Certification

8 8 Compressed Air Conditioning Filter G 3/8, 30 bar Filter G 3/8, 30 bar Flow Porosity Filter with condensate drain -20 C to +70 C max. 30 bar max Nl/min 25 µm 1.7 kg The filter is designed for filtering the air and for draining the condensate. s Symbol Input pressure Connection thread Filter max. 30 bar G 3/ Repair kit Assembly position as drawn. Please provide additional space for dismounting the container and draining of condensate.

9 Filter G 3/8, 30 bar (with clogging indicator) Compressed Air Conditioning 9 Filter G 3/8, 30 bar Flow Porosity Filter with clogging indicator -20 C to +70 C max. 30 bar max Nl/min 7 10 µm 1.7 kg The filter is designed for filtering the air and for draining the condensate. s Symbol Input pressure Connection thread Filter max. 30 bar G 3/ Repair kit Assembly position as drawn. Please provide additional space for dismounting the container.

10 10 Compressed Air Conditioning Filter, 40 bar Filter, 40 bar Porosity Filter with condensate drain -20 C to +70 C max. 40 bar 40 µm 0.7 kg The filter is designed for filtering the air and for draining the condensate. It s suitable for pressure regulator X 0 s Symbol Input pressure Nominal diameter Filter max. 40 bar ND Repair kit Assembly position as drawn. Please provide additional space for dismounting the container and draining of condensate.

11 Filter G 1 1/2, 40 bar Compressed Air Conditioning 11 Filter G 1 1/2, 40 bar Flow (at input pressure 6 bar and p=0,5 bar) Porosity Filter with condensate drain 0 C to +90 C max. 40 bar max Nl/min 40 µm 5.8 kg The filter is designed for filtering the air and for draining the condensate. s Symbol Input pressure Connection thread Filter max. 40 bar G 1 1/2 R Repair kit R Spare kit drain valve R Assembly position is open (flow direction has to be in direction of arrow).

12 12 Compressed Air Conditioning Filter G 1, 40 bar Filter G 1, 40 bar Flow (at input pressure 6 bar and p=0,2 bar) Porosity Filter with condensate drain +2 C to +70 C max. 40 bar max Nl/min 40 µm 2 kg The filter is designed for filtering the air and for draining the condensate. s Symbol Input pressure Connection thread Filter max. 40 bar G 1 R Repair kit R Spare kit drain valve R Assembly position as drawn. Please provide additional space for dismounting the container and draining of condensate.

13 Filter G 1/2, 40 bar Compressed Air Conditioning 13 Filter G 1/2, 40 bar Flow (at input pressure 6 bar and p=0,2 bar) Porosity Filter with condensate drain +2 C to +70 C max. 40 bar 2660 Nl/min 40 µm 1.3 kg The filter is designed for filtering the air and for draining the condensate. s Symbol Input pressure Connection thread Filter max. 40 bar G 1/2 R Repair kit R Spare kit drain valve R Assembly position as drawn. Please provide additional space for dismounting the container and draining of condensate.

14 14 Compressed Air Conditioning Filter G 3/8, 50 bar Filter G 3/8, 50 bar Flow Porosity Filter with condensate drain -20 C to +80 C max. 50 bar max Nl/min 25 µm 6.3 kg The filter is designed for filtering the air and for draining the condensate. s Symbol Input pressure Connection thread Filter max. 50 bar G 3/ Repair kit Assembly position as drawn. Please provide additional space for dismounting the container and draining of condensate.

15 Twin pressure reducing station with lever Compressed Air Conditioning 15 Twin pressure reducing station with lever Flow Connection threads Materials Housing Inside parts Twin pressure reducing valve with filter and mechanical trip point 0 C to +70 C max. 40 bar see table below M14 x 1.5 M22 x kg Aluminium, sea water resistant Stainless The twin pressure reducing station is designed for reducing a high input pressure to a lower outlet pressure as well as for filtering the air and draining of the condensed water. s Symbol Input temperature Outlet pressure Outlet pressure* Flow Response pressure safety valve* max. 40 bar 3 to 9.5 bar 7 bar 1400 Nl/min 8 bar max. 40 bar 3 to 9.5 bar 4 bar 1000 Nl/min 5 bar * Adjusting ex works. Repair kit The device has to be mounted vertically as shown and will be fastened by two screws M 10 x 120.

16 16 Compressed Air Conditioning Single pressure reducing station Single pressure reducing station Nominal diameter Connection threads Porosity Materials Housing Inside parts Pressure reducing valve with filter and safety valve -20 C to +70 C max. 40 bar ND7 M14 x µm 2.9 kg Stainless Aluminium, sea water resistant, red brass Stainless The single station is designed for reducing a high input pressure to a lower outlet pressure as well as for filtering the air and draining of the condensed water. s * Adjusting ex works. Symbol Input pressure Outlet pressure* Single station Response pressure safety valve* max. 40 bar 1.5 bar 2.5 bar max. 40 bar 6 bar 7 bar max. 40 bar 4 bar 5 bar max. 40 bar 3 bar 4 bar max. 42 bar 7 bar 8 bar max. 42 bar 10.5 bar 11.5 bar max. 42 bar 7.5 bar 8.5 bar Repair kit

17 Single pressure reducing station Compressed Air Conditioning 17 Single pressure reducing station 1) The device has to be mounted vertically as shown. Admissible deviation ±45 to drawn position. 1) Keep accessibility for parametrizing of device.

18 18 Compressed Air Conditioning Pressure regulator G 3/8, 30 bar Pressure regulator G 3/8, 30 bar Connection threads Flow (at input pressure 6 bar and p=1 bar) Diaphragm pressure regulator with secondary ventilation -20 C to +80 C max. 30 bar G 3/8 max Nl/min 1.2 kg The pressure regulator is designed for reducing a high input pressure to a lower outlet pressure. s Symbol Input pressure Outlet pressure Connection thread Pressure regulator max. 30 bar 0.35 to 10 bar G 3/ Repair kit )Assembly position is open (flow direction has to be in direction of arrow).

19 Pressure regulator G 3/8 with manometer, 10 bar Compressed Air Conditioning 19 Pressure regulator G 3/8 with manometer, 10 bar Connection threads Flow (at input pressure 6 bar and p=1 bar) Diaphragm pressure regulator with secondary ventilation -40 C to +95 C max. 10 bar G 3/8 max Nl/min 1.2 kg The pressure regulator is designed for reducing a high input pressure to a lower outlet pressure. s Symbol Input pressure Outlet pressure Connection thread Pressure regulator max. 10 bar 0.35 to 10 bar G 3/ Repair kit *) Assembly position is open (flow direction has to be in direction of arrow).

20 20 Compressed Air Conditioning Pressure regulator G 1, 40 bar Pressure regulator G 1, 40 bar Connection threads Flow Diaphragm pressure regulator with secondary ventilation -10 C to +90 C max. 40 bar G 1 see diagram below 3.6 kg The pressure regulator is designed for reducing a high input pressure to a lower outlet pressure. s Symbol Input pressure Outlet Pressure Connection thread Pressure regulator max. 40 bar 0.5 to 10 bar G 1 R Repair kit R Manometer R Assembly position is open (flow direction has to be in direction of arrow).

21 Pressure regulator G 1, 40 bar Compressed Air Conditioning 21 Pressure regulator G 1, 40 bar Flow quantity

22 22 Compressed Air Conditioning Pressure regulator G 1 1/2, 40 bar Pressure regulator G 1 1/2, 40 bar Connection threads Flow Diaphragm pressure regulator with secondary ventilation -10 C to +90 C max. 40 bar G 1 1/2 see diagram below 5.3 kg The pressure regulator is designed for reducing a high input pressure to a lower outlet pressure. s Symbol Input pressure Outlet pressure Connection thread Pressure regulator max. 40 bar 0.5 to 10 bar G 1 1/2 R Repair kit R Assembly position is open (flow direction has to be in direction of arrow).

23 Pressure regulator G 1 1/2, 40 bar Compressed Air Conditioning 23 Pressure regulator G 1 1/2, 40 bar Flow quantity

24 24 Compressed Air Conditioning Pressure regulator M22x1.5 Pressure regulator, M22x1.5 Connection threads Flow Diaphragm pressure regulator with secendary secondary ventilation -30 C to +70 C see table below M22 x 1.5 see table below 2 kg The pressure regulator is designed for reducing a high input pressure to a lower outlet pressure. s Symbol Input pressure Outlet pressure Flow 0-8 bar 1750 Nl/min max. 10 bar (preset pressure 6 bar) (at p=1bar) 1-8 bar 1750 Nl/min max. 40 bar (preset pressure 6 bar) (at p=1bar) Pressure regulator 1-8 bar 1750 Nl/min max. 40 bar (preset pressure 7 bar) (at p=1bar) 1) 1-15 bar 1750 Nl/min max. 40 bar (preset pressure 6 bar) (at p=1bar) Flow quantity for Repair kit for for for Screw plug for all versions Sealing ring for all versions Assembly position is open. Pv= operating pressure and Pz= working pressure. 1) GL-Certification: on request

25 Pressure regulator M22x1.5 Compressed Air Conditioning 25 Pressure regulator, M22x1.5 Assembly position is open. Keep accessibility for parametrizing of device.

26 26 Compressed Air Conditioning Oiler G 1/2, 16 bar Oiler G 1/2, 16 bar Oil dosage rate at qv=1000 l/min Oil type Tank type Tank volume Oiler with plastic tank max. +60 C max. 16 bar 1-2 drops/min HL 25 DIN ISO VG 32 Plastic 135 cm³ 3.3 kg The oiler is designed for oiling the air. s Symbol Input pressure Connection thread Oiler max. 16 bar G 1/2 R Assembly position as drawn.

27

28 Bosch Rexroth Pneumatics GmbH Marine Ulmer Straße 4 D Laatzen P. O. Box D Laatzen Phone Telefax marinesales@rexrothpneumatics.com The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The given information does not release the user from the obligation of own judgement and verification. It must be remem bered that our products are subject to a natural process of wear and aging. Subject to change. Printed in Germany. This edition supersedes all previous ones. No part of this edition may be reproduced without our prior permission. R / /EN

Air-service devices, Series MU1

Air-service devices, Series MU1 Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service Air-service devices, Series MU1 Technical data Pressure regulator valve, MU1, G 1 Technical Data Type Operating

More information

Directional valves Pneumatically operated Series CD07. Brochure

Directional valves Pneumatically operated Series CD07. Brochure Series CD07 Brochure 2 Bosch Rexroth AG Pneumatics Series CD07 2/2-way valve, Series CD07 Qn = 1400 l/min pipe connection compressed air connection output: M14x1,5 suitable for ATEX 3 3/2-way valve, Series

More information

Air service units series K G1/8, G1/4

Air service units series K G1/8, G1/4 Air service units series K Series FK Filter 12.011 Series RK Pressure regulator 12.012 Series FRK Filter/regulator 12.013 Series OK Lubricator 12.014 Series FROK Two piece air service unit 12.015 Series

More information

Series K Air service units G 1/8, G 1/4

Series K Air service units G 1/8, G 1/4 Air service units G /8, G /4 Series FK Filter, G /8 G /4.02 Series RK Pressure regulator, G /8 G /4.04 Series FRK Filter/regulator, G /8 G /4.06 Series OK Lubricator, G /8 G /4.08 Series FROK Two piece

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

Flow and check valves Supplementary products Shuttle valves (OR) Brochure

Flow and check valves Supplementary products Shuttle valves (OR) Brochure Flow and check valves Shuttle valves (OR) Brochure 2 Flow and check valves Shuttle valves (OR) Compressed air connection input: M5 - G 1/4 compressed air connection output: M5 - G 1/4 3 Qn = 80-6100 l/min

More information

Flow and check valves Logic valves series 551. Brochure

Flow and check valves Logic valves series 551. Brochure Flow and check valves Logic valves series 551 Brochure 2 Flow and check valves Logic valves series 551 3/2-directional valve, low pressure operated Qn = 2-120 l/min 3 3/2-directional valve, Qn = 120 l/min

More information

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with gauge suitable for ATEX 1 00119372 Version Parts Mounting orientation Working min./max. Medium Medium temperature

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 708 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point range 0.5 to bar (8 to 90 psi) The pressure regulator

More information

Flow and check valves Non-return valves Series NR02. Brochure

Flow and check valves Non-return valves Series NR02. Brochure Flow and check valves Non-return valves Series NR0 Brochure Flow and check valves Non-return valves Series NR0 Qn = 300-680 l/min thread-in 3 Qn = 70-800 l/min thread-in 5 Qn = 480-5800 l/min installing

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

Air service units series Y G1/4 to G1

Air service units series Y G1/4 to G1 Air service units series Y Series FY Filter, 12.071 Series RY+ RYP Pressure regulator, 12.076 Series FRY Filter/regulator, 12.080 Series OY Lubricator, 12.083 Series FROY Filter, Regulator, Lubricator

More information

Pressure regulators Pressure relief valves Safety valves. Brochure

Pressure regulators Pressure relief valves Safety valves. Brochure Pressure regulators Pressure relief valves Safety valves Brochure 2 Pressure regulators Pressure relief valves Safety valves Qn = 676-33505 l/min thread-in 3 Safety valve, Series RV2 Qn = 1833-13874 l/min

More information

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min Return Filters E E Tank top mounting Connection up to G¼ ominal flow rate up to l/min Description pplication In the return line circuits of hydraulic systems. Performance features Protection against wear:

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX /-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information

Check valve hydraulically pilot operated

Check valve hydraulically pilot operated Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents

More information

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6 List of Contents VMA System description Individual Units Pre-Filters 3 Micro-Filters Activated-Charcoal-Filters 5 Combinations Accessories and Main spare parts Service Units G 1 / Pre-Filter Micro-Filter

More information

Air preparation units

Air preparation units Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator

More information

Pressure regulators Manually operated Fine setting valves. Brochure

Pressure regulators Manually operated Fine setting valves. Brochure Pressure regulators Manually operated s Brochure Pressure regulators Manually operated s Qn = 9 l/min Actuating element: Push button Internal thread Poppet valve Qn = 9 l/min Actuating element: Push button

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

2-Port and 3-Port Seat Valves with Female Thread, PN16

2-Port and 3-Port Seat Valves with Female Thread, PN16 4 362 VVI4 VXI4 2-Port and 3-Port Seat Valves with Female Thread, PN6 VVI4... VXI4... ronze valve body CC49K (Rg5) DN5... DN50 k vs 2.5... 40 m 3 /h Female threaded connections Rp as to ISO 7/ Can be equipped

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated Pressure relief valve, direct operated RE 570/0.05 Replaces: 06.03 /8 Type DBD..K Size Component series X Maximum operating pressure 500 bar Maximum flow 0 l/min K9- Table of contents Contents Page Features

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65 Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)

More information

Pressure Reducing Valve DMV 750

Pressure Reducing Valve DMV 750 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction

More information

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

Vibration isolation system 1VIS10W. User manual

Vibration isolation system 1VIS10W. User manual Vibration isolation system 1VIS10W User manual Standa 2014 Table of contents 1. General information 3 1.1. Introduction 3 1.1.1. Safety 5 1.2. Location of the table 5 1.3. Air supply requirements 5 2.

More information

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3, 4, 6 Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with

More information

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of

More information

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

GENO -Flushing Compressor Product Data Sheet F 02

GENO -Flushing Compressor Product Data Sheet F 02 GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up

More information

Two-port seat valves

Two-port seat valves 4 345 Two-port seat valves with flange, PN16 VVF45... Two-port seat valves with flange, PN16 Spheroidal cast iron GGG-40 DN50...150 mm k vs 19...300 m 3 /h Stroke 20 or 40 mm Can be equipped with actuators

More information

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description 4 Ω-1 Ω Series Proportional Electro-ydraulic This relief and flow control valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since this valve controls

More information

Pressure Reducing Valve

Pressure Reducing Valve ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Advantages high reproducibility of setting pressure

More information

BULLETIN E485B. Poppet Valve Construction Customized Solutions Plug-and-Play Design. Subject to technical modifications.

BULLETIN E485B. Poppet Valve Construction Customized Solutions Plug-and-Play Design.   Subject to technical modifications. BULLETIN E485B Poppet Valve Construction Customized Solutions Plug-and-Play Design www.rosseuropa.com 1 Glossary Response Time The smallest nominal value difference that causes a change of the outlet pressure,

More information

Diaphragm relief valve

Diaphragm relief valve Product: Diaphragm relief valve Type: 620.10 622.10 623.10 624.10 625.10 626.10 627.10 Please state here the exact type and serial number of your diaphragm relief valve. (can be read off the type plate

More information

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 725 set range: 0,2-10,0 bar Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level

More information

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance

More information

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils 4 440 Three-port valves with flange, PN6 VXF4... Three-port valves with flange, PN6 Can be used as mixing or diverting valves Grey cast iron GG-25 DN5...50 mm k vs.9...300 m 3 /h Stroke 20 or 40 mm Can

More information

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design. BULLETIN E485A Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design www.rosseuropa.com 1 Glossary Response Time The smallest nominal value difference that causes a change

More information

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Operating Manual LTIA3E Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

L6090 (LC04M-CBL) - L6095 (LC04M-CBD) or 3 way pressure compensated flow regulators L69 (LC4M-CBL) - L695 (LC4M-CBD) RE 1833-4 Edition:.16 Replaces: 7.1 Size 4 Series Maximum operating pressure 31 bar (45 psi) Maximum flow (-way) 1 l/min (3.

More information

Pressure maintenance valve SDV-P / SDV-P-E

Pressure maintenance valve SDV-P / SDV-P-E Translation of the original manual Pressure maintenance valve SDV-P / SDV-P-E Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted

More information

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Hydraulic Accumulators with Back-Up Nitrogen Bottles Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter Due to its metal construction, the entire range of NEW DEAL elements is resistant to heavy duty working conditions. Designed for high pressure application (up to 18 bar). FIL filter Degree of filtration:

More information

Controllers DR, DP, FR and DFR

Controllers DR, DP, FR and DFR Controllers DR, DP, FR and DFR RE 9060 Edition: 04.014 Replaces: 10.006 For variable pump A4VSO series 1 and 3 Open circuit Features Control of pressure and flow Remote controlled optional Pressure controller

More information

2-port and 3-port valves PN 16

2-port and 3-port valves PN 16 OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port

More information

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use Pressure regulator made of brass Operating Manual 1. Intended Use Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to effect reduction to a downstream pressure

More information

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet V5001P Kombi-Auto Differential Pressure Control Valve Product specification sheet Content Application...1 Special Features...1 Valve Efficiency...1 Technical Data...2 Construction...2 Materials...2 Method

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators Self-operated Regulars Flow and Differential Pressure Regular Type 42-37 Flow and Differential Pressure or Flow and Pressure Regular Type 42-39 Type 42-37 Type 42-39 Fig. 1 Flow and differential pressure

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series NEWS 66 Components for Pneumatic Automation VALVES & AIR SERVICE UNITS STEEL LINE Series www.pneumaxspa.com Valves General The new Steel line valve series was created and developed specifically for the

More information

Coding of banjo flow controllers. Actuation M = Manual S = Screwdriver

Coding of banjo flow controllers. Actuation M = Manual S = Screwdriver Flow control valves Unidirectional and bidirectional (meter-in, meter-out, orifice) banjo flow controllers Series SCU, MCU, SVU, MVU, SCO, MCO Ports M5, 1/8, 1/4, 3/8, 1/2 BSPP (without adapters) General

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

Flanged pressure reducer/stabilizer VRCD

Flanged pressure reducer/stabilizer VRCD Flanged pressure reducer/stabilizer VRCD 2 This unit reduces and stabilizes the upstream pressure by operating on its load losses with a constant downstream pressure irrespective of the rate of flow value.

More information

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1... 4/3 Directional valve elements L8L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L8L1...(EDC-LV) RE 1831-17 Edition: 2.216 Replaces: 7.12 Size 6 Series Maximum

More information

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at

More information

Diaphragm Accumulators

Diaphragm Accumulators 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.

More information

Diaphragm Pressure Keeping Valve

Diaphragm Pressure Keeping Valve Product: Diaphragm pressure keeping valve Type: 620.D 622.D 623.D 624.D 625.D 626.D 627.D Please state here the exact type and serial number of your diaphragm pressure keeping valve. (can be read off the

More information

Valves. Diaphragm shut-off valves, kidney-type

Valves. Diaphragm shut-off valves, kidney-type Valves Diaphragm shut-off valves, kidney-type Application When leakage of even the smallest quantities must be avoided with certainty For maximum requirements to operating safety For maximum requirements

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled Pressure regulator FRNG Zero pressure regulator Proportional pressure regulator Compressed air-controlled pressure regulator 4.14 Printed in Germany Edition 01.18 Nr. 219 570 Technical description The

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Industrial Hydraulics Electric Drives and Controls Linear Motion and ssembly echnologies Pneumatics Service utomation Mobile Hydraulics Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 750 set range: bar Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

safety Shut-Off Valve HON 721

safety Shut-Off Valve HON 721 safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety

More information

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Operating Manual LTIA5E Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical data

More information

Operating and maintenance manual Filter and reducing station Series / 1.0

Operating and maintenance manual Filter and reducing station Series / 1.0 Operating and maintenance manual Filter and reducing station Series 961 04.2017 / 1.0 Original instructions ARCA Regler GmbH. All rights reserved. Cover picture background: Freepik.com ARCA Regler GmbH

More information

Safety Shut-Off Valve HON 720

Safety Shut-Off Valve HON 720 Safety Shut-Off Valve HON 70 Product information serving the gas industry worldwide Application, Characteristics, Technical Data Application main safety device for gas pressure regulating stations suitable

More information

Piloted Non-Return Valves

Piloted Non-Return Valves ed Non-Return Valves ed non-return valves are designed to protect installations: if the compressed air supply is removed, they lock the air supply to the cylinder, thus maintaining it in position. Product

More information

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a

More information

Precision pressure regulators LRP/LRPS

Precision pressure regulators LRP/LRPS Precision pressure regulators LRP/LRPS q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators Page 1 of 6 TI-P510-01 H Issue 5 IP2, IP2 and IP2D ISO 9001 Spirax-Monnier International ompressed ir Filter/ Regulators ert. No. LRQ 0963008 Description The IP range of Spirax-Monnier international compressed

More information

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body NEW - HZE Air Treatment Units CHARACTERISTICS Ambient temperature Working pressure Max pressure Body Knob Ring nut Bowl Bowl guard Filter element Seals Springs Diaphragm CODIFICATION KEY H Z E B 8 G +6

More information

Instruction Manual Contact Pressure Gauge

Instruction Manual Contact Pressure Gauge MS11 Instruction Manual Contact Pressure Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance 7.

More information