TYPE APPROVAL CERTIFICATE

Size: px
Start display at page:

Download "TYPE APPROVAL CERTIFICATE"

Transcription

1 <0> DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E This is to certify that the Electric Power Cable with type designation(s) CS 90 MBZH YZp & & 0,6/1 kv, CS 90 MBZH YZafp 0,6/1 kv Manufactured by B.V. Twentsche Kabelfabriek HAAKSBERGEN, Netherlands is found to comply with Det Norske Veritas' Rules for Classification of Ships, High Speed & Light Craft and Det Norske Veritas' Offshore Standards IEC ( ) IEC ( ) IEC /2 ( ) IEC ( ) Application General power and lighting. Flame retardant in buch Cat. A. Halogen free. Low smoke. Type Voltage class (kv) Temp. class ( C) CS 90 MBZH YZp & & 0,6/1 kv 0,6/1 90 CS 90 MBZH YZafp 0,6/1 kv 0,6/1 90 Høvik, for Det Norske Veritas AS This Certificate is valid until Marit Laumann Head of Section DNV local office: Rotterdam Ivar Bull Surveyor This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas. Form No.: TA 1411a Issue: October 2009 Page 1 of 5

2 Product description Type: CS 90 MBZH YZp HALOGEN FREE 0,6/1 kv CS 90 MBZH YZp HALOGEN FREE 0,6/1 kv CS 90 MBZH YZp HALOGEN FREE 0,6/1 kv Construction: Conductors: Plain or tinned stranded copper class 2, round or sector shaped or class 5 () Core insulation: XLPE Filler: Non hygroscopic tape or Halogen free filler ( and ) Outher sheath: SHF1 1 x 1 4,7 5,3-2 x 1 7,2 7,8-3 x 1 7,6 8,2-4 x 1 8,5 9,1-5 x 1 9,2 9,8-6 x 1 9, x 1 9, x 1 11, x 1 12, x 1 12, x 1 12, x 1 13, x 1 13, x 1 13, x 1 14, x 1 14, x 1 15, x 1 15, x 1 15, x 1 16, x 1 16, x 1 17, x 1 17, x 1 18, x 1 18, x 1 18, x 1 18, x 1 16, x 1 19, x 1 19,0-31 x 1 20, x 1 20, x 1 20, x 1 20, x 1 20, x 1 20, x 1 20, x 1,5 5,0 5,6-2 x 1,5 7,8 8,6-3 x 1,5 8,2 9,0-4 x 1,5 9,2 9,8-5 x 1,5 10,0 10,6-6 x 1,5 10, x 1,5 10, x 1,5 12, x 1,5 13, x 1,5 14, x 1,5 14, x 1,5 14, x 1,5 15, x 1,5 15, x 1,5 16, x 1,5 16, x 1,5 17, x 1,5 17, x 1,5 17, x 1,5 17, x 1,5 17, x 1,5 18, x 1,5 18, x 1,5 20, x 1,5 20, x 1,5 20, x 1,5 20, x 1,5 18, x 1,5 21, x 1,5 21, x 1,5 22, x 1,5 22, x 1,5 22,2 - - Form No.: TA 1411a Issue: October 2009 Page 2 of 5

3 34 x 1,5 23, x 1,5 23, x 1,5 23, x 1,5 23, x 2,5 5,4 6,0-2 x 2,5 8,8 9,4-3 x 2,5 9,3 9,9-4 x 2,5 10,1 10,7-5 x 2,5 11,2 11,8-6 x 2,5 12, x 2,5 12, x 2,5 13, x 2,5 15, x 2,5 15, x 2,5 15, x 2,5 16, x 2,5 17, x 2,5 17, x 2,5 18, x 2,5 18, x 2,5 19, x 2,5 19, x 2,5 19, x 2,5 20, x 2,5 20, x 2,5 21, x 2,5 21, x 2,5 22, x 2,5 22, x 2,5 22, x 2,5 23, x 2,5 20, x 2,5 23, x 2,5 23, x 2,5 25, x 2,5 25, x 2,5 25, x 2,5 26, x 2,5 26, x 2,5 26, x 2,5 26, x 4 5,9 6,5-2 x 4 9,8 10,4-3 x 4 10,4 11,2-4 x 4 11,6 12,2-5 x 4 12,6 13,2-1 x 6 6,4 7,0-2 x 6 10,8 11,6-3 x 6 11,7 12,3-4 x 6 12,8 13,4-5 x 6 14,1 14,7-1 x 10 7,2 7,8-2 x 10 12,6 13,2-3 x 10 13,4 14,2-4 x 10 14,9 15,5-5 x 10 16,3 17,1-1 x 16 8,1 8,9 9,9 2 x 16 14,6 15,2 16,9 3 x 16 15,5 16,1 17,8 4 x 16 17,3 17,9 19,6 5 x 16 18,9 19,7 21,2 1 x 25 9,8 10,4 11,6 2 x 25 17,8 18,4 20,1 3 x 25 19,0 19,8 21,3 4 x 25 21,1 21,7 23,4 5 x 25 23,4 24,0 25,7 1 x 35 10,9 11,7 12,7 2 x 35 20,2 20,8 22,5 3 x 35 21,6 22,4 23,9 4 x 35 24,0 24,8 26,3 5 x 35 26,6 27,4 28,9 1 x 50 12,6 13,2 14,9 2 x 50 23,4 24,0 25,7 3 x 50 25,2 25,8 27,5 4 x 50 28,0 28,6 30,3 5 x 50 31,0 31,6 33,3 1 x 70 14,4 15,0 16,7 2 x 70 26,8 27,6 29,1 3 x 70 28,9 29,5 31,2 4 x 70 32,1 32,9 34,4 5 x 70 35,7 36,3 38,5 1 x 95 16,0 16,8 18,3 2 x 95 30,4 31,0 32,5 3 x 95 32,5 33,3 34,8 4 x 95 36,3 36,9 39,1 5 x 95 40,2 41,0 43,0 1 x ,8 18,4 20,1 2 x ,8 34,4 36,6 3 x ,4 37,0 39,2 4 x ,4 41,2 43,2 5 x ,0 45,6 47,8 1 x ,8 20,4 22,1 Form No.: TA 1411a Issue: October 2009 Page 3 of 5

4 2 x ,6 38,4 40,4 3 x ,5 41,3 43,3 4 x ,4 46,4 48,4 5 x ,4 51,2 53,4 1 x ,7 22,5 24,0 2 x ,8 42,4 44,6 3 x ,0 45,6 47,8 4 x ,4 51,2 53,4 5 x ,0 56,8 59,0 1 x ,3 25,1 26,6 2 x ,2 48,0 50,2 3 x ,7 51,7 53,7 4 x ,6 57,6 59,8 5 x ,0 63,8 66,0 1 x ,7 27,5 29,0 2 x ,0 52,8 55,0 3 x ,9 56,7 58,9 4 x ,5 63,3 65,5 5 x ,4 70,2 72,4 Type: CS 90 MBZH YZafp 0,6/1 kv: 2 1 x 1,5 5,6 2 x 1,5 8,6 3 x 1,5 9 4 x 1,5 9,8 5 x 1,5 10,6 6 x 1,5 11,6 7 x 1,5 11,6 8 x 1,5 12,9 9 x 1, x 1,5 14,6 11 x 1,5 14,6 12 x 1, x 1,5 15,7 14 x 1,5 15,7 15 x 1,5 16,8 16 x 1,5 16,8 17 x 1,5 17,6 18 x 1,5 17,6 19 x 1,5 17,6 20 x 1,5 18, x 1,5 18,5 22 x 1,5 19,7 23 x 1,5 19,7 24 x 1,5 20,6 25 x 1,5 20,6 26 x 1,5 20,6 27 x 1, x 1,5 21,7 32 x 1,5 22,8 37 x 1,5 23,6 1 x 2,5 6 2 x 2,5 9,4 3 x 2,5 9,9 4 x 2,5 10,7 5 x 2,5 11,8 6 x 2,5 12,8 7 x 2,5 12,8 8 x 2,5 14,4 9 x 2,5 15,6 10 x 2,5 16, x 2,5 16,2 12 x 2,5 16,9 13 x 2,5 17,7 14 x 2,5 17,7 15 x 2,5 18,6 16 x 2,5 18,6 17 x 2,5 19,8 18 x 2,5 19,8 19 x 2,5 19,8 20 x 2,5 20,9 21 x 2,5 20,9 22 x 2,5 22,1 23 x 2,5 22,1 24 x 2,5 23,2 25 x 2,5 23,2 26 x 2,5 23,2 27 x 2,5 23,7 30 x 2,5 24,7 32 x 2,5 25,6 37 x 2,5 26,6 Application/Limitation The requirements of SOLAS Amendments Chapter II-1, Part D, Reg. 45, 5.2 (provision to be taken to limit Fire Propagation along Bunches of Cables or Wires) are fulfilled without any additional measures. Type Approval documentation Tests carried out Standard Release General description Limitation Form No.: TA 1411a Issue: October 2009 Page 4 of 5

5 Standard Release General description Limitation IEC General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications IEC Insulating materials for shipboard and offshore units, power, control, instrumentation, telecounication and data cables IEC Electrical installations in ships - Part 353: Power cables for rated voltages 1kV and 3kV IEC Sheathing materials for shipboard power and telecounication cables IEC Flame retardance in bunch, cat. A IEC Test on gases evolved during combustion of materials from cables Determination of the amount of halogen acid gas IEC Test on gases evolved during combustion of materials from cables Determination of the degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring ph and condctivity IEC / Measurement of smoke density of cables burning under defined conditions Test apparatus, procedure and requirements Low Halogen: <0,5% Halogen Halogen free: ph > 4,3 Conductivity < 10µS/ Light transmittance > 60% Marking of product TKF - Size - 0,6/1kV - CS 90 mbzh - YZp HALOGEN FREE - {batch nr} TKF - Size - 0,6/1kV - CS 90 mbzh - YZp 0,6/1kV HALOGEN FREE - {batch nr} TKF - Size - Class 5-0,6/1kV - CS 90 mbzh - YZp 0,6/1kV HALOGEN FREE - {batch nr} TKF - Size Class 5 - CS 90 mbzh - YZafp 0,6/1kV {batch nr} Certificate retention survey The scope of the retention/renewal survey is to verify that the conditions stipulated for the Type approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the survey are: Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Type Approval Certificate. Survey to be performed at least every second year. END OF CERTIFICATE Form No.: TA 1411a Issue: October 2009 Page 5 of 5

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-13345 This is to certify that the Terminal Block with type designation(s) ST-COMBI, ST, STS Issued to Phoenix Contact GmbH & Co. KG Blomberg,

More information

SLOP RECEPTION AND PROCESSING FACILITIES

SLOP RECEPTION AND PROCESSING FACILITIES RULES FOR CLASSIFICATION OF SHIPS NEWBUILDINGS SPECIAL SERVICE AND TYPE ADDITIONAL CLASS PART 5 CHAPTER 8 SLOP RECEPTION AND PROCESSING FACILITIES JANUARY 2011 CONTENTS PAGE Sec. 1 General Requirements...

More information

Assessment of Ships and Managers for the Acceptance of Extended Interval Between Bottom Surveys in Dry-Dock

Assessment of Ships and Managers for the Acceptance of Extended Interval Between Bottom Surveys in Dry-Dock CLASSIFICATION NOTES No. 72.2 Assessment of Ships and Managers for the Acceptance of Extended Interval Between Bottom Surveys in Dry-Dock MAY 2012 The electronic pdf version of this document found through

More information

Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL.

Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. Certificate No: TAP000006X This is to certify: That the Ballast Water Management System with type designation(s) Optimarin Ballast System, Optimarin Ballast System Ex Issued to Optimarin A/S Sandnes, Norway

More information

N.I.V. Bluestar Plus

N.I.V. Bluestar Plus Innovative range of masks N.I.V. Bluestar Plus The air at service of breathing Lightness Seal Comfort KOO MEDICAL EQUIPMENT www.koomedical.com The comfort of the anatomic cushion NEW Facial Mask - Intensive

More information

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2 RULES FOR CLASSIFICATION OF SHIPS NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2 REDUNDANT PROPULSION JANUARY 1996 CONTENTS PAGE Sec. 1 General Requirements... 5 Sec. 2 System

More information

RULES FOR CLASSIFICATION Yachts. Part 5 Ship types Chapter 3 Passenger Yachts. Edition December 2015 DNV GL AS

RULES FOR CLASSIFICATION Yachts. Part 5 Ship types Chapter 3 Passenger Yachts. Edition December 2015 DNV GL AS RULES FOR CLASSIFICATION Yachts Edition December 2015 Part 5 Ship types Chapter 3 Passenger Yachts The content of this service document is the subject of intellectual property rights reserved by ("DNV

More information

YSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control

YSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control YSLY-JZ YSLY-OZ Construction: VDE Reg. n 7509 according to VDE 0281 Teil 13 according to DIN EN 50525-2-51 Flame propagation: DIN EN 60332-1-2 Low

More information

Electrical Shore Connections

Electrical Shore Connections RULES FOR CLASSIFICATION OF Ships / High Speed, Light Craft and Naval Surface Craft PART 6 CHAPTER 29 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Electrical Shore Connections JULY 2014

More information

CY LSOH Screened Halogen Free Control Cables with improved fire performance

CY LSOH Screened Halogen Free Control Cables with improved fire performance LSZH Screened Flexible Control Cable Application Range For installation where fire, smoke emission and toxic fumes Create a potential threat to life and equipment. Can be used as interconnecting cable

More information

RULES FOR CLASSIFICATION. Yachts. Part 5 Ship types Chapter 3 Passenger yachts. Edition October 2016 DNV GL AS

RULES FOR CLASSIFICATION. Yachts. Part 5 Ship types Chapter 3 Passenger yachts. Edition October 2016 DNV GL AS RULES FOR CLASSIFICATION Yachts Edition October 2016 Part 5 Ship types Chapter 3 The content of this service document is the subject of intellectual property rights reserved by ("DNV GL"). The user accepts

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAA0000123 This is to certify: That the Pressure Transmitter with type designation(s) SITRANS P series DS III, P310, P410 Issued to Siemens AG - Process Industries

More information

Type MMV Medium Power Cable

Type MMV Medium Power Cable 7-05 Type MMV Medium Power Cable Single Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Conductors Soft annealed flexible stranded

More information

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS

RULES FOR CLASSIFICATION Naval vessels. Part 1 Classification and surveys Chapter 5 Surveys for submarines. Edition January 2016 DNV GL AS RULES FOR CLASSIFICATION Naval vessels Edition January 2016 Part 1 Classification and surveys Chapter 5 The content of this service document is the subject of intellectual property rights reserved by ("DNV

More information

AIR VENT HEADS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2008

AIR VENT HEADS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2008 STANDARD FOR CERTIFICATION No..9 AIR ENT HEADS OCTOBER 008 eritasveien 1, NO-13 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DN) is an autonomous and independent foundation with the

More information

LNG BOIL-OFF RE-LIQUEFACTION PLANTS AND GAS COMBUSTION UNITS

LNG BOIL-OFF RE-LIQUEFACTION PLANTS AND GAS COMBUSTION UNITS CASSIFICATION NOTES No. 61.2 NG BOI-OFF RE-IQUEFACTION PANTS AND GAS COMBUSTION UNITS MAY 2006 Veritasveien 1, NO-1322 øvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous

More information

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE Compiled by: Arthur Cameron NOT SO CORRECT SELECTION AND INSTALLATION OF CABLE GLANDS AND JUNCTION BOXES IN HAZARDOUS AREAS

More information

STABILITY AND WATERTIGHT INTEGRITY, CLOSING APPLIANCES

STABILITY AND WATERTIGHT INTEGRITY, CLOSING APPLIANCES RULES FOR CLASSIFICATION OF HIGH SPEED, LIGHT CRAFT AND NAVAL SURFACE CRAFT STRUCTURES, EQUIPMENT PART 3 CHAPTER 6 STABILITY AND WATERTIGHT INTEGRITY, CLOSING APPLIANCES JANUARY 2011 CONTENTS PAGE Sec.

More information

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper June 2013 Section A-All questions carry equal marks. Answer all three questions. Show all calculations. 1. The electrical installation in an industrial unit is scheduled for a periodic

More information

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant Comtran Cable Commercial Premise & Specialty Datacom Products Cat 5e - Cat 6A LSZH & Industrial Ethernet Indoor/Outdoor & Outside Plant Category 6 : UL Type CMP : UL Type CMR Commercial Premise =====================================================================

More information

HYDRAULIC CYLINDERS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2009

HYDRAULIC CYLINDERS STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No OCTOBER 2009 STANDARD FOR CERTIFICATION No..9 HYDRAUIC CYINDERS OCTOBER 009 Veritasveien 1, NO-13 Høvik, Norway Tel.: +7 67 57 99 00 Fax: +7 67 57 99 11 FOREWORD (DNV) is an autonomous and independent foundation with

More information

Semoflex Roboschlepp The PUR cable for cable chains

Semoflex Roboschlepp The PUR cable for cable chains Semoflex Roboschlepp The PUR cable for cable chains Description Application For use in cable chains and continual moving machines and robots. Because of the polyurethane outer sheath the cable outer diameter

More information

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C GmbH PRODUCT INFORMATION Proven all-weather control cables resistant to a wide range of chemical media Outstanding weather, ozone and UV resistance together with the wide temperature range enable versatile

More information

Halogen free cable. Halogen free cable

Halogen free cable. Halogen free cable SABIX Flame retardent Non Corrosive, FRNC, is an halogen free material based on Polyolefi n that fulfi lls the international norms (IEC) when it comes to fl ame propagation. These cables in different versions

More information

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV MV-05 MEDIUM VOLTAGE CABLE 5kV, 8kV, 5kV, 5kV & 5kV MV-05 MEDIUM VOLTAGE POWER CABLE 5kV % INSULATION LEVEL 8kV 00% INSULATION LEVEL Conductor conforming to ASTM B and Class B Compact stranded in accordance

More information

PURA. Pure Gas Dewpoint Transmitter. Users Guide

PURA. Pure Gas Dewpoint Transmitter. Users Guide PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter

More information

23.1 Functions, Basic Configuration, and Interfaces

23.1 Functions, Basic Configuration, and Interfaces 23 (6.6.D) SF 6 and Other Special Gases 23.1 Functions, Basic Configuration, and Interfaces 23.1.1 Functions The primary function performed by the SF 6 and other special gases system is to provide SF 6

More information

M-06 Nitrogen Generator (Nitrogen Making Machine)

M-06 Nitrogen Generator (Nitrogen Making Machine) Guideline No.M-06 (201510) M-06 Nitrogen Generator (Nitrogen Making Machine) Issued date: 20 th October, 2015 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains

More information

Part 7 Fleet in service Chapter 2 Inclining test and light weight check

Part 7 Fleet in service Chapter 2 Inclining test and light weight check RULES FOR CLASSIFICATION Inland navigation vessels Edition December 2015 Part 7 Fleet in service Chapter 2 Inclining test and light weight check The content of this service document is the subject of intellectual

More information

SAFETY QUALITY TECHNOLOGY. Guidance on Safe Isolation Procedures

SAFETY QUALITY TECHNOLOGY. Guidance on Safe Isolation Procedures SAFETY QUALITY TECHNOLOGY Guidance on Safe Isolation Procedures Introduction Every year, people working on construction sites suffer electric shock and burn injuries some of which, tragically, are fatal.

More information

W E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard.

W E NE E D TO TA LK A BOUT COLD FLOW. The Problem With The Cold Flow Standard. W E NE E D TO TA LK A BOUT COLD FLOW The Problem With The Cold Flow Standard www.ehawke.com CONTENTS 03 COLD FLOW AND THE STANDARDS The Cold Flow Standard misnomer The Problem with Compression and Displacement

More information

Dynamic Positioning Systems

Dynamic Positioning Systems RULES FOR CLASSIFICATION OF Ships PART 6 CHAPTER 7 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Dynamic Positioning Systems JULY 2014 The electronic pdf version of this document found through

More information

DT400/436 Tee Connector Installation Instructions

DT400/436 Tee Connector Installation Instructions Connectors Lorem ipsum and dolor Splices sit Amat Effective September 2014 Supersedes IS550-30-1 March 2011 MN650001EN DT400/436 Tee Connector Installation Instructions DISCLAIMER OF WARRANTIES AND LIMITATION

More information

HV Spiker Kit - CSTE. 30 th April 2014

HV Spiker Kit - CSTE. 30 th April 2014 HV Spiker Kit - CSTE 30 th April 2014 Safety Working With Cables As a cable jointer, safety is paramount when working daily with live electricity. When working with cables it is essential to know whether

More information

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

UNIK 5600/5700 Marine Certified Pressure Sensing Platform GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.

More information

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031) IEC 62271-200 April 2004 Authorized Sole Agent : PT. Wisma Niagatama Perkasa Phone : (031) 5041242 Fax. : (031) 5044580 IEC 62271-200 Introduction Scope This standard specifies requirements for factory-assembled

More information

SILENT CLASS NOTATION

SILENT CLASS NOTATION RULES FOR CLASSIFICATION OF SHIPS NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 24 SILENT CLASS NOTATION JANUARY 2010 CONTENTS PAGE Sec. 1 General Requirements... 5 Sec. 2

More information

Pleasure Boat Inspection

Pleasure Boat Inspection in cooperation with SBA Pleasure Boat Inspection A complete guide to a successful preparation This publication contains all necessary information related to pleasure boat inspection and is a valuable 258

More information

Cable Accessories Contents Pg 64. Lighting Components Contents Pg 88. Cables Contents Pg 4 & 5. Lamps Contents Pg 95. Lightings Contents Pg 28

Cable Accessories Contents Pg 64. Lighting Components Contents Pg 88. Cables Contents Pg 4 & 5. Lamps Contents Pg 95. Lightings Contents Pg 28 Extension Cable Reel/Socket Distribution Box Wonpro BH Global Marine Limited is a supply chain management company specialising in premium lightings, cables and electrical equipments. We provide one stop

More information

Sockets. terminations

Sockets. terminations Sockets Wire rope terminations Introduction With a dedicated team of professionals, a state-of-the-art production facility and global distribution, Ropeblock is the leading supplier for the lifting and

More information

Amphenol. PowerLink Solar Cables. Amphenol 97 Series Connectors are UL recognized and CSA recognized.

Amphenol. PowerLink Solar Cables.   Amphenol 97 Series Connectors are UL recognized and CSA recognized. Amphenol PowerLink Solar Cables www.amphenol-industrial.com Amphenol 97 Series Connectors are UL recognized and CSA recognized. PowerLink Solar Cables Amphenol s single conductor PowerLink Solar Cables

More information

POWER DELIVERY. Contractor Health & Safety General Terms and Conditions. Appendix B Personal Protective Equipment

POWER DELIVERY. Contractor Health & Safety General Terms and Conditions. Appendix B Personal Protective Equipment Personal Protective Equipment ( PPE ): All PPE worn on IPL job sites must have ANSI and/or approval ratings. Hard hats and safety glasses with side shields (including prescription eyewear) shall be worn

More information

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure controls for hydro carbons, zone II applications, Type KPE MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

7.0 Compliance certificates

7.0 Compliance certificates 7.0 Compliance certificates IN THIS SECTION: 7.1 What are compliance certificates? 7.2 Certified handler compliance certificates 7.3 Approved filler certificate 7.4 Location compliance certificates 7.5

More information

Reliability Analysis Including External Failures for Low Demand Marine Systems

Reliability Analysis Including External Failures for Low Demand Marine Systems Reliability Analysis Including External Failures for Low Demand Marine Systems KIM HyungJu a*, HAUGEN Stein a, and UTNE Ingrid Bouwer b a Department of Production and Quality Engineering NTNU, Trondheim,

More information

These Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National

These Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National These Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National Grid, on or near to its electricity apparatus. National

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

RESOLUTION MSC.236(82) (adopted on 1 December 2006) ADOPTION OF AMENDMENTS TO THE GUIDELINES FOR THE TRANSPORT AND HANDLING OF LIMITED AMOUNTS OF

RESOLUTION MSC.236(82) (adopted on 1 December 2006) ADOPTION OF AMENDMENTS TO THE GUIDELINES FOR THE TRANSPORT AND HANDLING OF LIMITED AMOUNTS OF RESOLUTION MSC.236(82) (adopted on 1 December 2006) ADOPTION OF AMENDMENTS TO THE GUIDELINES FOR THE TRANSPORT AND HANDLING OF LIMITED AMOUNTS OF HAZARDOUS AND NOXIOUS LIQUID SUBSTANCES IN BULK THE MARITIME

More information

Chapter 16 - Protective Equipment

Chapter 16 - Protective Equipment Chapter 16 Protective Equipment Chapter 16 - Protective Equipment Introduction Hayward Electric will provide suitable equipment to protect employees from hazards in the workplace. The Responsible Safety

More information

Pressure transmitters EMP 2

Pressure transmitters EMP 2 Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,

More information

SMARTen STP Patch Cords Features

SMARTen STP Patch Cords Features Features Patch Cords are used in the work area and cross-connect generic cabling applications Comprise a length of eight-wire flexible patch cable, terminated with two eight-position RJ-45 plugs at each

More information

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN Connectors MN650027EN Effective November 2016 Supersedes January 2014 (IS550-11-1) DS250 deadbreak straight connector installation instructions interface A COOPER POWER SERIES DISCLAIMER OF WARRANTIES

More information

PECIMEN IMM6. Minor Electrical Installation Works Certificates. Amd 3: In accordance with BS 7671

PECIMEN IMM6. Minor Electrical Installation Works Certificates. Amd 3: In accordance with BS 7671 IMM6 NCR (No Carb o n Requi red) Minor Electrical Installation Works Certificates Installer s Reference Number IRN/ PART 1: DETAILS OF THE MINOR WORKS Client: minor works completed: IMM6/ MINOR ELECTRICAL

More information

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN Screened Separable Connectors MN650025EN Effective November 2016 Supersedes September 2013 (IS550-10-1) DE250 deadbreak elbow connector installation instructions interface A COOPER POWER SERIES DISCLAIMER

More information

REQUIREMENTS FOR ONBOARD LIFTING APPLIANCES AND ANCHOR HANDLING WINCHES

REQUIREMENTS FOR ONBOARD LIFTING APPLIANCES AND ANCHOR HANDLING WINCHES E SUB-COMMITTEE ON SHIP SYSTEMS AND EQUIPMENT 5th session Agenda item 10 SSE 5/10/3 18 January 2018 Original: ENGLISH REQUIREMENTS FOR ONBOARD LIFTING APPLIANCES AND ANCHOR HANDLING WINCHES Comments on

More information

To: Relevant departments of CCS Headquarters, Plan approval centers, CCS surveyors, relevant shipyards, designers and shipping companies

To: Relevant departments of CCS Headquarters, Plan approval centers, CCS surveyors, relevant shipyards, designers and shipping companies Form: RWPRR401-B CCS Circular China Classification Society (2012) Circ. No. 14 Total No.176 January 29, 2012 (Total pages: 1+5 ) To: Relevant departments of CCS Headquarters, Plan approval centers, CCS

More information

CMC Series Moulded Case Circuit Breaker Cielo Electric

CMC Series Moulded Case Circuit Breaker Cielo Electric Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

REGULATION 22. STANDARD RELATING TO THE USE OF ARTIFICIAL RUGBY TURF

REGULATION 22. STANDARD RELATING TO THE USE OF ARTIFICIAL RUGBY TURF REGULATION 22 REGULATION 22. STANDARD RELATING TO THE USE OF ARTIFICIAL RUGBY TURF 22.1 Definitions For the purposes of this Regulation 22 the terms below shall have the following meanings assigned to

More information

OFFSHORE. Trasfor OFFSHORE

OFFSHORE. Trasfor OFFSHORE OFFSHORE Trasfor OFFSHORE 2 Trasfor I Offshore Introduction Trasfor s transformers for offshore applications ensure the highest performance level of reliability in any working condition. More than 40 skilled

More information

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS SECTION 7 ELECTRICITY CHAPTERS A APPROACH B DOCUMENTS, REGULATIONS AND

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

Ultima. X Series Gas Monitor

Ultima. X Series Gas Monitor Ultima X Series Gas Monitor Safety Manual SIL 2 Certified " The Ultima X Series Gas Monitor is qualified as an SIL 2 device under IEC 61508 and must be installed, used, and maintained in accordance with

More information

Pro-Tekt European Cable System. Technical Catalog

Pro-Tekt European Cable System. Technical Catalog European Cable System Technical Catalog High-Performance Cables for Demanding Applications Every cable application is important, and durable, long-lasting equipment requires rugged reliability. Downtime

More information

Metering Code Gas TSO, measurement by connected party Effective from to the present

Metering Code Gas TSO, measurement by connected party Effective from to the present Please note that although Gasunie Transport Services B.V. translated the Dutch network codes with utmost care, Gasunie Transport Services B.V. would like to point out that only the decisions of the Dutch

More information

ANNEX 15. RESOLUTION MEPC.158(55) Adopted on 13 October 2006

ANNEX 15. RESOLUTION MEPC.158(55) Adopted on 13 October 2006 MEPC 55/23 RESOLUTION MEPC.158(55) THE MARINE ENVIRONMENT PROTECTION COMMITTEE, RECALLING Article 38(a) of the Convention on the International Maritime Organization concerning the functions of the Marine

More information

GUIDELINES FOR SURVEY OF OIL FLOATING STORAGE VESSELS FIXED AT ANCHORAGE

GUIDELINES FOR SURVEY OF OIL FLOATING STORAGE VESSELS FIXED AT ANCHORAGE GUIDANCE NOTES GD03-2017 CHINA CLASSIFICATION SOCIETY GUIDELINES FOR SURVEY OF OIL FLOATING STORAGE VESSELS FIXED AT ANCHORAGE 2017 Effective from 1 March 2017 BEIJING Chapter 1 GENERAL 1.1 Application

More information

CAYMAN ISLANDS SHIPPING REGISTRY YACHT ENGAGED IN TRADE

CAYMAN ISLANDS SHIPPING REGISTRY YACHT ENGAGED IN TRADE SHIPPING NOTICE Maritime Authority of the Cayman Islands Head Office 3 rd Floor, Government Administration Building, 133 Elgin Avenue PO Box 2256, Grand Cayman, KY1-1107, Cayman Islands Tel: +1 345 949

More information

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk (June 1999) (Rev.1 Mar 2006) (Rev.2 May 2007) (Rev.3 Mar 2010) (Corr.1 Feb 2011) (Rev.4 Oct 2013) Periodical surveys of cargo installations on ships carrying liquefied gases in bulk 1 General 1.1 Scope

More information

Electronic Instrumentation

Electronic Instrumentation Shielded multipair and multitriad - 00V - 105 C - PLTC - UL 1 Applications Electronic instrumentation, analog and digital signal circuits (-ma). Intrinsically safe circuits. Gas and/or fluid leak detection

More information

Status Date Prepared Reviewed Endorsed Approved

Status Date Prepared Reviewed Endorsed Approved Discipline Engineering Standard NSW Category Signalling Title Introduction to Signalling Maintenance Procedures Reference Number SMP 01 (RIC Standard: SC 00 52 00 01 SI) Document Control Status Date Prepared

More information

EASIDEW TRANSMITTER with Current Source Output

EASIDEW TRANSMITTER with Current Source Output EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element

More information

RESOLUTION MSC.397(95) (adopted on 11 June 2015) AMENDMENTS TO PART A OF THE SEAFARERS' TRAINING, CERTIFICATION AND WATCHKEEPING (STCW) CODE

RESOLUTION MSC.397(95) (adopted on 11 June 2015) AMENDMENTS TO PART A OF THE SEAFARERS' TRAINING, CERTIFICATION AND WATCHKEEPING (STCW) CODE RESOLUTION MSC.397(95) (adopted on 11 June 2015) THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning the functions of the Committee,

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Stator Resistance Thermometers

Stator Resistance Thermometers Stator esistance hermometers www.technocontrols.com A complete solution for temperature sensing of electrical rotary machines Simplex (Single element) stator winding Ds Model: SE series ( Single element)

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers.

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers. Product family Current transformers Current transformers (CTs) are introduced where it is difficult to access a direct measuring ot network current. Current transformer transforms the high network current

More information

Hangt de baggerindustrie aan een (zijden) draadje

Hangt de baggerindustrie aan een (zijden) draadje Lloyd s Register: Business unit Marine Hangt de bagger industrie aan een (zijden) draadje Door: Cor Dekker Senior Specialist Marine Equipment & Lifting Components The Group at a glance 278 offices delivering

More information

PRODUCT INFORMATION. Extension- and compensating cables, multi-paired

PRODUCT INFORMATION. Extension- and compensating cables, multi-paired PVC insulated - with and without steel wire armouring or foil screen Extension and compensating cables, multi-paired version - suitable for use in temperature measurement and manufacturing process control

More information

Hollandse Kust (zuid) Wind resource assessment. 17 January 2017 Anthony Crockford

Hollandse Kust (zuid) Wind resource assessment. 17 January 2017 Anthony Crockford Hollandse Kust (zuid) Wind resource assessment 17 January 2017 Overview > Introduction > Wind measurements > Mesoscale model > Calculation of wind climate > Comparisons > Conclusions 2 ECOFYS WTTS 17/01/2017

More information

Guideline No.: L-01(201510) L-01 LIFEJACKETS. Issued date: October 20,2015. China Classification Society

Guideline No.: L-01(201510) L-01 LIFEJACKETS. Issued date: October 20,2015. China Classification Society Guideline No.: L-01(201510) L-01 LIFEJACKETS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY CERTIFICATE OF CONFORMITY No. ROSS US.GB05.V03061 Valid from 8/12/2010 through 8/12/2013 No. 0422555 CERTIFICATION AGENCY ROSS RU.0001.11GB05 NONPROFIT INDEPENDENT RESEARCH ORGANIZATION (), CERTIFICATION

More information

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , , ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR 1910.331 335-29 CFR 1926.302, 1926.416, 1926.417 BASIS: The National Safety Council estimates that there are at least 300 deaths

More information

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper April 2013 Section A - All questions carry equal marks. Answer all three questions. Show all calculations. Q.1 The electrical installation in a small food retail outlet is scheduled

More information

ARC:Gear from Unipart Rail

ARC:Gear from Unipart Rail :Gear from Unipart Rail Innovation in Clothing for Safe Working with Electrification SERVING THE WORLD S RAILWAYS Our Service Unipart Rail has partnered with PHS Besafe in creating a service to the UK

More information

Solar Sport One Notice of Race 2017 Version july, 2017

Solar Sport One Notice of Race 2017 Version july, 2017 Solar Sport One Notice of Race 2017 Version july, 2017 The Notice of Race presented in this document were drawn up to serve as directives for the race. Situations that are not covered by the Rules will

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE Page 1 / 4 Certificate number: 23445/A0 BV File number: AP 4160 Product code: 4440I This certificate is not valid when presented without the full attached schedule composed of 7 sections www.veristar.com

More information

This Procedure details the procedures to be followed in order to achieve Safety from the System when:

This Procedure details the procedures to be followed in order to achieve Safety from the System when: 1 SCOPE This Procedure details the procedures to be followed in order to achieve Safety from the System when: using Insulated Tools within the Vicinity Zone or the Live Zone, when carrying out Tree Work

More information

Arran LED Floodlight Luminaire

Arran LED Floodlight Luminaire Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical

More information

OTL Universal terminals

OTL Universal terminals OTL Universal terminals 2019 Universal terminals OTL Universal terminals OTL 1000 V AC/DC Bimetal (AL/CU) Class A Certified according to standards EN 612381 and EN 6094771 2 Universal terminals OTL Universal

More information

Progressive Safety Services LLC - All Rights Reserved

Progressive Safety Services LLC - All Rights Reserved Estimated that 2,000 workers are treated in specialized burn centers each year as a result of arc flash (Electrical Safety Foundation International). According to the National Safety Council, medical costs

More information

The IEC61508 Inspection and QA Engineer s hymn sheet

The IEC61508 Inspection and QA Engineer s hymn sheet The IEC61508 Inspection and QA Engineer s hymn sheet A few key points for those inspectors and QA engineers involved with a project using the IEC61508 group of standards by the 61508 Association SAFETY

More information

ARC:Gear from Unipart Rail

ARC:Gear from Unipart Rail :Gear from Unipart Rail Innovation in Clothing for Safe Working with Electrification SERVING THE WORLD S RAILWAYS What is an Electric Arc flash? It is a continuous electric discharge of high current between

More information

O&M MANUAL HIGHLIGHTS

O&M MANUAL HIGHLIGHTS O&M MANUAL HIGHLIGHTS GENERAL PROVISIONS Each pipeline must be operated according to this SUBPART 192.603(a) RECORDS 192.603(b) Keep records necessary to administer the procedures of 192.605 RECORDS Life

More information

The IEC61508 Project Manager's & Project Engineer's hymn sheet

The IEC61508 Project Manager's & Project Engineer's hymn sheet The IEC61508 Project Manager's & Project Engineer's hymn sheet A few key points for those project managers and project engineers undertaking a project using the IEC61508 group of standards by the 61508

More information

F GENERAL RULES OF COMPETITION

F GENERAL RULES OF COMPETITION SECTION F GENERAL RULES OF COMPETITION IMPBA OFFICIAL RULE BOOK GENERAL RULES OF COMPETITION I - AMATEUR STATUS... F - 1 II - REQUIREMENTS FOR MODEL POWER BOATS... F - 1 III - SAFETY & CODE OF CONDUCT...

More information

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) Miniature size in-line Thermocouple Socket with stainless

More information