1 Datasheet ENGLISH IEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N (Note: Illustration shows Type T with standard connectors and Type K with miniature connectors for indication only) Thermocouple extension leads available with either miniature or standard IEC thermocouple connectors, types K, J, T & N, in 2 metre, 5 metre and 10 metre lengths Specifications Thermocouple Cable Construction: Single pair 7/0.2 PVC insulated cable / wire Laid flat, side by side & PVC sheathed Tolerance class 2 Insulation rating -10 to 105 C IEC colour coded Miniature Thermocouple Connectors: Miniature connector with flat plug pins Miniature socket with thermocouple contacts Contacts are polarised to prevent incorrect connection Max temperature 220 C IEC colour coded Standard Thermocouple Connectors: Standard connector with solid, round plug pins Standard socket with thermocouple contacts Suitable for industrial applications Contacts are polarised to prevent incorrect connection Max temperature 220 C IEC colour coded

2 Order codes: Extension Leads with Miniature Thermocouple Plug & Socket Connectors PLUG & SOCKET CONNECTORS CABLE LENGTH (mtrs) IEC COLOUR CODE ALLIED CODE TYPE CODE RS PART NUMBER K Miniature 2 EXT-K-C1-2.0-MP-MS GREEN K Miniature 5 EXT-K-C1-5.0-MP-MS GREEN K Miniature 10 EXT-K-C MP-MS GREEN J Miniature 2 EXT-J-C1-2.0-MP-MS BLACK J Miniature 5 EXT-J-C1-5.0-MP-MS BLACK J Miniature 10 EXT-J-C MP-MS BLACK T Miniature 2 EXT-T-C1-2.0-MP-MS BROWN T Miniature 5 EXT-T-C1-5.0-MP-MS BROWN T Miniature 10 EXT-T-C MP-MS BROWN N Miniature 2 EXT-N-C1-2.0-MP-MS PINK N Miniature 5 EXT-N-C1-5.0-MP-MS PINK N Miniature 10 EXT-N-C MP-MS PINK Extension Leads with Standard Thermocouple Plug & Socket Connectors TYPE PLUG & SOCKET CONNECTORS CABLE LENGTH (mtrs) CODE IEC COLOUR CODE ALLIED CODE RS PART NUMBER K Standard 2 EXT-K-C1-2.0-SP-SS GREEN K Standard 5 EXT-K-C1-5.0-SP-SS GREEN K Standard 10 EXT-K-C SP-SS GREEN J Standard 2 EXT-J-C1-2.0-SP-SS BLACK J Standard 5 EXT-J-C1-5.0-SP-SS BLACK J Standard 10 EXT-J-C SP-SS BLACK T Standard 2 EXT-T-C1-2.0-SP-SS BROWN T Standard 5 EXT-T-C1-5.0-SP-SS BROWN T Standard 10 EXT-T-C SP-SS BROWN N Standard 2 EXT-N-C1-2.0-SP-SS PINK N Standard 5 EXT-N-C1-5.0-SP-SS PINK N Standard 10 EXT-N-C SP-SS PINK Making your own Thermocouples?

3 L60 Thermocouple & Fine Wire Welder The Thermocouple Welder is a compact, simple-to-use instrument designed for thermocouple and fine wire welding It is primarily designed for use by sensor manufacturers to produce commercial grade thermocouple junctions; it is ideal for producing large numbers of exposed junction thermocouples for test and development laboratories. The L60 Thermocouple Welder is ideally suited to transducer and RTD extension lead attachment Use of the Thermocouple Welder does not require special skills and most operatives will be capable of producing quality work with little practice. The instrument is supplied with a full range of user accessories including a footswitch Suitable for use with wires of up to 1.1mm diameter an argon gas shield facility is included but a satisfactory thermocouple junction is produced without the need for argon. The output energy of the L60 Thermocouple Welder can be varied up to 60 Joules Simple to use Thermocouple Welder Designed for the production of commercial grade thermocouple junctions (See below for range of thermocouple cables) Also suitable for other fine wire work Front panel or footswitch operation Argon gas shield facility Supplied complete with the following accessories: Wire Holding Pliers & Lead Safety Glasses Magnifying Eyeglass Carbon Electrodes Spare 2A Fuse Argon Hose Mains Lead Footswitch for greater ease of use Carbon Electrode ORDERING INFORMATION MODEL Allied Code RS ORDER NUMBER FINE WIRE WELDER Spare Carbon Electrodes (x5) for 1.1mm 250V Fine Wire Welder

4 SPECIFICATIONS General Energy Output 0-60 Joules Welding Capacity Wires up to 1.1mm diameter Duty Cycle Minimum 5-10 welds/min MECHANICAL Physical Dimensions 220mm Wide x 120mm High x 250mm Depth Weight 4kg ELECTRICAL Power Supply Vac or Vac, 50-60Hz Power Consumption Max 170VA dropping to 20VA during charging MAINTENANCE Apart from keeping the electrode in good order, no other maintenance is required (Front View) (Rear View)

5 Thermocouple Welder Controls A Arc Argon gas and weld current controlled by the Weld switch. LED indication B Purge Allows the gas line and electrode shield to be purged of air prior to a new welding period C Weld Switch Initiates a welding operation (in arc mode also opens the Argon valve) D Argon LED Indicates when the Argon control valve is open and gas is flowing E Wait LED Glows when weld charge is building F Ready LED Ready to Weld indication G Power Rotary control of the capacitor charge voltage H Level Selector Selects the total capacitance available giving the following values with LED indication "LO" = 0 to 6 Joules "MED" = 0 to 28 Joules "HI" = 0 to 64 Joules I Electrode Holder Holds the replaceable carbon electrode which is accessible by removing the outer Argon Shield J Red Socket Output socket for using the pliers supplied K Black Socket Output socket, this provides an additional earth IEC PTFE Insulated Twin Twisted Pair Thermocouple Cable Available in Thermocouple Types K, J T & N Type K Type T

6 PTFE twin twisted pair for extending or making simple thermocouples Single pair of PTFE insulated conductors twisted together Good mechanical strength and flexibility, resistant to oils, acids and other adverse fluids Suitable for steam & pressure applications, autoclaves, sterilizers etc. 25 & 50 metre reel lengths Tolerance Class 1 for optimum accuracy Insulation rating -75 C to 260 C Colour coded to IEC T/C Type Conductors Cores Reel Length Allied code RS order code J 1/0.2mm +Black/-White 25 metres J 1/0.2mm +Black/-White 50 metres J 1/0.315mm +Black/-White 25 metres J 1/0.315mm +Black/-White 50 metres K 1/0.315mm +Green/-White 25 metres K 1/0.315mm +Green/-White 50 metres T 1/0.315mm +Brown/-White 25 metres T 1/0.315mm +Brown/-White 50 metres J 1/0.508mm +Black/-White 25 metres J 1/0.508mm +Black/-White 50 metres K 1/0.508mm +Green/-White 25 metres K 1/0.508mm +Green/-White 50 metres J 7/0.2mm +Black/-White 25 metres K 7/0.2mm +Green/-White 25 metres T 7/0.2mm +Brown/-White 25 metres N 7/0.2mm +Pink/-White 25 metres IEC PVC Insulated Flat Pair Thermocouple Extension & Compensating Cable PVC Insulated Flat Pair (to IEC-584) PVC insulated flat pair construction Conductors laid flat PVC insulated with overall PVC sheath All round general purpose cable, both waterproof and very flexible Thermocouple extension types for K, J, T & N

7 Compensating types VX (KCB) & U (RCA) for types K & R/S Thermocouples respectively Stranded conductors available, either 7/0.2mm or 13/0.2mm Available in 10, 25, 100 & 200 metre lengths Tolerance Class 2 Insulation rating -10 C to 105 C Colour code (cores & jacket) to IEC Conductors Cores Jacket Reel Length Allied RS order code Code Extension: KX 7/0.2mm +Green/-White Green 10 metres KX 7/0.2mm +Green/-White Green 25 metres KX 7/0.2mm +Green/-White Green 50 metres KX 7/0.2mm +Green/-White Green 100 metres KX 7/0.2mm +Green/-White Green 200 metres JX 7/0.2mm +Black/-White Black 10 metres JX 7/0.2mm +Black/-White Black 25 metres JX 7/0.2mm +Black/-White Black 50 metres JX 7/0.2mm +Black/-White Black 100 metres JX 7/0.2mm +Black/-White Black 200 metres TX 7/0.2mm +Brown/-White Brown 10 metres TX 7/0.2mm +Brown/-White Brown 25 metres TX 7/0.2mm +Brown/-White Brown 50 metres TX 7/0.2mm +Brown/-White Brown 100 metres TX 7/0.2mm +Brown/-White Brown 200 metres NX 7/0.2mm +Pink/-White Pink 10 metres NX 7/0.2mm +Pink/-White Pink 25 metres NX 7/0.2mm +Pink/-White Pink 50 metres NX 7/0.2mm +Pink/-White Pink 100 metres Conductors Cores Jacket Reel Length Allied RS order code Code Compensating: VX (KCB) 7/0.2mm +Green/-White Green 10 metres VX (KCB) 7/0.2mm +Green/-White Green 25 metres VX (KCB) 7/0.2mm +Green/-White Green 50 metres VX (KCB) 7/0.2mm +Green/-White Green 100 metres VX (KCB) 7/0.2mm +Green/-White Green 200 metres VX (KCB) 13/0.2mm +Green/-White Green 10 metres VX (KCB) 13/0.2mm +Green/-White Green 25 metres VX (KCB) 13/0.2mm +Green/-White Green 50 metres VX (KCB) 13/0.2mm +Green/-White Green 100 metres U (RCA) 7/0.2mm +Orange/-White Orange 10 metres U (RCA) 7/0.2mm +Orange/-White Orange 25 metres U (RCA) 7/0.2mm +Orange/-White Orange 50 metres U (RCA) 13/0.2mm +Orange/-White Orange 10 metres U (RCA) 13/0.2mm +Orange/-White Orange 25 metres U (RCA) 13/0.2mm +Orange/-White Orange 50 metres

8 IEC PTFE Single Shot Thermocouple Cable Type K, 10 metre reel Thermocouple type K 10 metre spool length 7/0.2mm diameter conductor Operating range: -75 C to +250 C Teflon insulated single shot construction Resistant to chemicals, oils and fliuds Suitable for aerospace applications and is widly used in autoclaves Colour coded to IEC Type Outer Length Allied code RS Code K Green/White 10 metres ANSI PFA Insulated Twin Twisted Pair Thermocouple Cable Available in Thermocouple Types K & T (ANSI MC96.1) Type KX Type TX PFA Teflon twin twisted pair for extending or making simple thermocouples Single pair of PFA insulated conductors twisted together Good mechanical strength and flexibility, resistant to oils, acids and other adverse fluids, gasses, steam etc. Thermocouple types K & T with 1/0.2mm OR 1/0.3 conductors. 7/0.2mm option available for type K 25, 50 & 100 metre reel lengths Tolerance Class 1 for optimum accuracy

9 Insulation rating -75 C to 260 C Colour coded to ANSI MC96.1 T/C Type Conductors Cores Reel Length Allied code RS order code KX 1/0.2mm +Yellow/-Red 25 metres KX 1/0.2mm +Yellow/-Red 50 metres KX 1/0.2mm +Yellow/-Red 100 metres KX 7/0.2mm +Yellow/-Red 25 metres KX 7/0.2mm +Yellow/-Red 50 metres KX 7/0.2mm +Yellow/-Red 100 metres KX 1/0.3mm +Yellow/-Red 25 metres KX 1/0.3mm +Yellow/-Red 50 metres KX 1/0.3mm +Yellow/-Red 100 metres TX 1/0.3mm +Blue/-Red 25 metres TX 1/0.3mm +Blue/-Red 50 metres TX 1/0.3mm +Blue/-Red 100 metres TX 1/0.2mm +Blue/-Red 25 metres TX 1/0.2mm +Blue/-Red 50 metres TX 1/0.2mm +Blue/-Red 100 metres ANSI PVC Thermocouple Extension & Compensating Cable PVC Insulated Flat Pair (ANSI MC96.1) Type KX Type JX Type TX PVC insulated flat pair construction Conductors laid flat PVC insulated with overall PVC sheath All round general purpose cable, both waterproof and very flexible Thermocouple extension types for K, J, & T Compensating types VX (KCB) for types K Thermocouples

10 Stranded conductors available, 7/0.2mm Available in 25, 100 & 200 metre lengths Tolerance Class 2 Insulation rating -10 C to 105 C Colour code (cores & jacket) to ANSI MC96.1 T/C Type Conductors Cores Jacket Reel Length Allied RS order code code Extension: KX 7/0.2mm +Yellow/-Red Yellow 25 m KX 7/0.2mm +Yellow/-Red Yellow 100 m KX 7/0.2mm +Yellow/-Red Yellow 200 m JX 7/0.2mm + White/-Red Black 25 m JX 7/0.2mm + White/-Red Black 100 m JX 7/0.2mm + White/-Red Black 200 m TX 7/0.2mm +Blue/-Red Blue 25 m TX 7/0.2mm +Blue/-Red Blue 100 m TX 7/0.2mm +Blue/-Red Blue 200 m Compensating: VX (KCB) 7/0.2mm +Yellow/-Red Yellow 25 m VX (KCB) 7/0.2mm +Yellow/-Red Yellow 100 m VX (KCB) 7/0.2mm +Yellow/-Red Yellow 200 m

ENGLISH. Datasheet L60 Thermocouple & Fine Wire Welder

ENGLISH. Datasheet L60 Thermocouple & Fine Wire Welder Datasheet L60 Thermocouple & Fine Wire Welder ENGLISH The Thermocouple Welder is a compact, simple-to-use instrument designed for thermocouple and fine wire welding It is primarily designed for use by

More information

ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug

ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug Thermocouple types K, J & T Fast response, welded exposed junction 1, 2, 5 or 10 metre lengths available Teflon

More information

Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code)

Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code) Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code) ENGLISH Thermocouple types K & T to ANSI MC96.1 Fast response, welded exposed junction 1, 2, 5 or 10-metre-long Teflon PFA

More information

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code ENGLISH These quick connect versions allow rapid termination Miniature connector

More information

Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)

Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code) Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code) ENGLISH Duplex (2-channel) standard connector that accepts solid, round plug pins Bodies supplied

More information

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) Miniature size in-line Thermocouple Socket with stainless

More information

Extension and compensating cables, single-paired version - suitable for use in temperature measurement and manufacturing process control

Extension and compensating cables, single-paired version - suitable for use in temperature measurement and manufacturing process control PVC, silicone, FEP or glass fibre-insulated Extension and compensating cables, single-paired version - suitable for use in temperature measurement and manufacturing process control Info Available in many

More information

PRODUCT INFORMATION. Extension- and compensating cables, multi-paired

PRODUCT INFORMATION. Extension- and compensating cables, multi-paired PVC insulated - with and without steel wire armouring or foil screen Extension and compensating cables, multi-paired version - suitable for use in temperature measurement and manufacturing process control

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C GmbH PRODUCT INFORMATION Proven all-weather control cables resistant to a wide range of chemical media Outstanding weather, ozone and UV resistance together with the wide temperature range enable versatile

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

User Manual V14.1 IP68 LED FLEX NEON

User Manual V14.1 IP68 LED FLEX NEON User Manual V14.1 IP68 LED FLEX NEON PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE END USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE 1/11 PRODUCT SPECIFICATION 1. Operating

More information

SMARTen STP Patch Cords Features

SMARTen STP Patch Cords Features Features Patch Cords are used in the work area and cross-connect generic cabling applications Comprise a length of eight-wire flexible patch cable, terminated with two eight-position RJ-45 plugs at each

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A

More information

Digital Melting Point Apparatus

Digital Melting Point Apparatus Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature

More information

e2c 20 - easy to connect

e2c 20 - easy to connect closer contacts Fieldbus Communications e2c 20 - easy to connect e2c 20 / IP 20 Distributed I/O System for Switch Cabinets Switch cabinets and distribution boxes continue to rely on wiring systems that

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

Halogen free cable. Halogen free cable

Halogen free cable. Halogen free cable SABIX Flame retardent Non Corrosive, FRNC, is an halogen free material based on Polyolefi n that fulfi lls the international norms (IEC) when it comes to fl ame propagation. These cables in different versions

More information

Pre-Calibrated Models

Pre-Calibrated Models Quick Selection Guide Factory-calibrated to match thermocouple signals over selected temperature ranges For non-metal surfaces (coated metals are acceptable) For use with thermocouple input controllers,

More information

Welding With Arc Welding Equipment

Welding With Arc Welding Equipment Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Welding With Arc Welding Equipment Self Inspection Checklist Guidelines: This checklist

More information

Deep Submersible Level Transducer Series 300DS

Deep Submersible Level Transducer Series 300DS KPSI Transducers Deep Submersible Level Transducer Series 300DS FEATURES! Custom Level Ranges up to 4614 ft (1408 m) H 2 O! Accuracy of ±0.5% FS! Analog Outputs of 4-20 ma or 0-5 VDC! Welded 316 SS Construction!

More information

RG2 Gripper Datasheet Version 1.6

RG2 Gripper Datasheet Version 1.6 RG2 Gripper Datasheet Version 1.6 The RG2 gripper is a flexible electric gripper specially designed for robots from Universal Robots. The long stroke allows the gripper to handle a variety of object sizes.

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315 PORTABLE WORK LIGHT MODEL NO: CL6FS PART NO: 4003530 OPERATION INSTRUCTIONS GC0315 INTRODUCTION Thank you for purchasing this CLARKE Worklight. Before attempting to use this product, please read this manual

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

LECTRAFLEX CABLE AND WIRE. 46 Concentric jacketing provides consistent abrasion resistance

LECTRAFLEX CABLE AND WIRE. 46  Concentric jacketing provides consistent abrasion resistance Concentric jacketing provides consistent abrasion resistance Paper wrapped for ease of stripping* UV protected jacketing resists magnesium and calcium chlorides and other chemicals* Excellent abrasion

More information

AutoChanger Installation & User Guide Issue 2

AutoChanger Installation & User Guide Issue 2 1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide

More information

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation. INSTRUMENTATION COURSE 510: 3 DAYS: Max 8 Candidates This course covers the key aspects of industrial instrumentation and is designed to enable maintenance personnel to carry out commissioning, calibration

More information

Variable Area Flow Meters

Variable Area Flow Meters PDF Published May, 04 Variable Area Flow Meters Chemline F Series Variable Area Flow Meters are ideal for plastic piping. They provide a combination of accurate visual flow rate measurement and clear flow

More information

PUR cable. PUR cable. The harmonised version H05BQ-F/H07BQ-F can be used at building construction areas and where HAR-approval is required in Europe.

PUR cable. PUR cable. The harmonised version H05BQ-F/H07BQ-F can be used at building construction areas and where HAR-approval is required in Europe. Polyurethan (PUR) cables are suitable as control cables, for fl exible use where high mechanical stress occurs. The PUR outer jacket has very good resistance against mineral oils and different chemical

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

T EK-SUB 4800C 19 mm Submersible Level Transmitter

T EK-SUB 4800C 19 mm Submersible Level Transmitter Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2

More information

FIELD DEVICES ANALYTICAL Product Specifications

FIELD DEVICES ANALYTICAL Product Specifications FIELD DEVICES ANALYTICAL Product Specifications PSS 6-1C6 A EP462 Series ph Sensors - Twist-Lock Mount OVERVIEW The EP462 Series is a family of twist-lock style combination ph sensors designed for quick

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

Ventam 85 Installation & Commissioning Instructions

Ventam 85 Installation & Commissioning Instructions Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Ventam 85 Installation & Commissioning Instructions 1 General The Ventam

More information

Zirconia Oxygen Sensors. Model 1230 Series

Zirconia Oxygen Sensors. Model 1230 Series Zirconia Oxygen Sensors Model 1230 Series March 2003 USING THIS MANUAL CAUTION 1 The probe or sensor heater is supplied with mains voltage. This supply has electrical shock danger to maintenance personnel.

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

analytical bulk flow distance FLOW level pressure temperature industrial communication

analytical bulk flow distance FLOW level pressure temperature industrial communication analytical bulk flow distance level pressure temperature industrial communication isolv THERMAL MASS METER Measuring Principle Self-heated Sensor Reference Sensor isolv Thermal Mass Flow Meters have two

More information

ELADOS EDP L Diaphragm Metering Pump Type

ELADOS EDP L Diaphragm Metering Pump Type ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably

More information

HD 9/18-4 ST. Adaptation according to requirements thanks to retrofitting capability. Individual configurability saves investment costs

HD 9/18-4 ST. Adaptation according to requirements thanks to retrofitting capability. Individual configurability saves investment costs The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and tear. 1 2 3 4 1 2 Adaptation

More information

FRANKLIN MOTOR DATA BOOKLET

FRANKLIN MOTOR DATA BOOKLET FRANKLIN MOTOR DATA BOOKLET We Keep You In The Game! 8100 AMF Drive Mechanicsville, VA 23111 1-866-460-QAMF (7263) FRANKLIN MOTOR PARTS - QubicaAMF PART NUMBERS Item Qty Description 785 502 261 60Hz Combo

More information

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0127 Rocker valve 2/2 or 3/2-way solenoid valve 2/2 oder 3/2-Wege Magnetventil Vanne magnétique 2/2 ou 3/2 Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions...2

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11 Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double

More information

STARLOG. Capacitive Water Depth Probe

STARLOG. Capacitive Water Depth Probe STARLOG Capacitive Water Depth Probe Model 6521 User Manual Supplement 6219 Revision D July 10. 1998 Copyright Notice Copyright Unidata Australia 1998. All rights reserved. No part of this publication

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

DTG - LCD Digital Temperature Gauge USER MANUAL

DTG - LCD Digital Temperature Gauge USER MANUAL DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

Features. RP011 - Compact Multimedia X-Slim Keyboard. Brief Specification Product Dimension: Keyboard:320(L) 160(W) 14.5(H)mm

Features. RP011 - Compact Multimedia X-Slim Keyboard. Brief Specification Product Dimension: Keyboard:320(L) 160(W) 14.5(H)mm RP011 - Compact Multimedia X-Slim Keyboard Features X slim keyboard 7 hot keys Brief Specification Product Dimension: Keyboard:320(L) 160(W) 14.5(H)mm Package Includes:.X-Slim Keyboard System Requirements

More information

EASIDEW TRANSMITTER with Current Source Output

EASIDEW TRANSMITTER with Current Source Output EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element

More information

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection

More information

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with / brake / 9 www.igus.de MOT-AN-S_EN_2070# part number (not configurable, only for illustration)

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual ORB-400 BUBBLE/HAZE MACHINE Item ref: 160.462UK User Manual Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty Introduction Thank you for

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400 Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400 C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating

More information

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions METEOR LSR36500 UNDERWATER POOL LIGHT Operating Instructions LIGHTING CONTENTS Preface...3 Features...3 Precautions...3 Components and Connectors...4 Installation...5 Controls...7 Appearance...8 Technical

More information

Keep the balance in sight

Keep the balance in sight Keep the balance in sight FLUID CONTROL 2225 Suction and irrigation pump for gynecology, urology and surgery FLUID CONTROL 2225 One pump. Three specialisms. No license fees. The new FLUID CONTROL 2225

More information

Less power great performances

Less power great performances 148 SMART SMART Less power great performances SMART is the answer to the increasing demand for both low energy consumption and high efficiency. Based on many years experience in road lighting, it offers

More information

HI 2314 HI 2315 HI 23151

HI 2314 HI 2315 HI 23151 Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction

More information

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1 High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0 High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET AC 2007-1108: ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET Matthew Braley, University of Idaho Paul Anderson, University of Idaho Tracey Windley, University of Idaho Kevin Buck, University

More information

INDUSTRIAL CUTTING EQUIPMENT

INDUSTRIAL CUTTING EQUIPMENT INDUSTRIAL CUTTING EQUIPMENT Catalogue : NIWC 1046 We reserve the right to introduce changes to our product range and /or designs without prior notice Cold Cutting Equipment Section No. Description Colour

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

AMS 2710 PCB pressure sensor module with V output

AMS 2710 PCB pressure sensor module with V output FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,

More information

Digital Flow Switch. Series PFM7

Digital Flow Switch. Series PFM7 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

Series Environmental Chambers

Series Environmental Chambers 3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable

More information

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP 00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle

More information

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY Table of Contents Introduction - EcoPRO-Series

More information

INSTRUCTION MANUAL. Lesker Model KJL615TC-K Lesker Model KJL615TC-H. Digital Vacuum Gauge/Controller. KJL615TC K/H Ranges

INSTRUCTION MANUAL. Lesker Model KJL615TC-K Lesker Model KJL615TC-H. Digital Vacuum Gauge/Controller. KJL615TC K/H Ranges INSTRUCTION MANUAL Lesker Model KJL615TC-K Lesker Model KJL615TC-H Digital Vacuum Gauge/Controller KJL615TC K/H Ranges 1 to 1999 millitorr 1 to 1990 microbar 1 to 199.9 Pascal Standard Features Selectable

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel TANK MANAGER FOR TWO TANKS OPERATING MANUAL 10/31/11 C-More T6C L color touch panel 1 TABLE OF CONTENTS GENERAL...3 INSTALLATION...4 STONE TEST PROCEDURE...7 OPERATIONAL SUMMARY...7 AUTO CARBONATION...10

More information

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983 Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement

More information

Semoflex Roboschlepp The PUR cable for cable chains

Semoflex Roboschlepp The PUR cable for cable chains Semoflex Roboschlepp The PUR cable for cable chains Description Application For use in cable chains and continual moving machines and robots. Because of the polyurethane outer sheath the cable outer diameter

More information

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

UNIK 5600/5700 Marine Certified Pressure Sensing Platform GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.

More information

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1 Discovery SDT 650 Site Preparation Guide Revision G Issued December 2018 Page 1 Table of Contents Table of Contents... 2 Ideal Setup... 3 System Components... 4 With Discovery Mass Spectrometer... 4 With

More information

MODEL NO: TIG200HFACDC

MODEL NO: TIG200HFACDC INSTRUCTIONS FOR: TIG/MMA HF AC/DC INVERTER WELDER 200A 230V MODEL NO: TIG200HFACDC Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

More information

PyroCouple Series Operators Guide

PyroCouple Series Operators Guide PyroCouple Series Operators Guide english PyroCouple, non-contact infrared sensors measure temperatures from -20 C to 500 C and provide either a linear 4 to 20mA output, a voltage output or a thermocouple

More information

CY LSOH Screened Halogen Free Control Cables with improved fire performance

CY LSOH Screened Halogen Free Control Cables with improved fire performance LSZH Screened Flexible Control Cable Application Range For installation where fire, smoke emission and toxic fumes Create a potential threat to life and equipment. Can be used as interconnecting cable

More information

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES ALL PICTURES SHOWN ARE FOR REFERENCE ONLY ACTUAL PRODUCT MAY VARY

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

QPEO2/033N Credit Value: 14 QCF Level: 2 GLH: 64 Wiring and testing electrical equipment and circuits

QPEO2/033N Credit Value: 14 QCF Level: 2 GLH: 64 Wiring and testing electrical equipment and circuits Performing Engineering Operations QPEO2/033N Credit Value: 14 QCF Level: 2 GLH: 64 Wiring and testing electrical equipment and Learner Name: EAL Assessment Route Summary This EAL assessment route covers

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

CONTROL and INSTRUMENTATION

CONTROL and INSTRUMENTATION CONTROL and INSTRUMENTATION COURSE 500: 5 DAYS: Max 8 Candidates This course covers the key aspects of current instrumentation and process control technology and is designed to enable maintenance personnel

More information