Validity of the iphone 5S M7 motion co-processor. as a pedometer for able-bodied persons. Micah Alford 9/7/2014
|
|
- Betty Barber
- 5 years ago
- Views:
Transcription
1 Validity of the iphone 5S M7 motion co-processor as a pedometer for able-bodied persons Micah Alford 9/7/2014
2 Abstract Objectives: The specific aim of this study is to assess the concurrent validity of the iphone 5S s M7 motion co-processor as a pedometer for able-bodied persons. Method: Participants of this trial will walk a 30 meter course at three self-selected speeds: self-selected comfortable, comfortably slow, and comfortably fast with the iphone 5S in the right hip pocket and a StepWatch 3 Activity monitor (Orthocare Innovations, Mountlake Terrace, WA) attached just proximally to their right lateral malleolus. Statistical analysis will be conducted to determine if the iphone 5S is a valid instrument as a pedometer in an able-bodied population. Results: Results show that the iphone compared to the manual count is only strongly correlated at fast speeds (ρ=.83, p<.001) Table 1. When the iphone was compared to the StepWatch, it was found to be moderately correlated at normal speeds (ρ=.406, p=.075) Table 1 and strongly correlated at fast speeds (ρ=.773, p<.001) Table 1. Speed was moderately and inversely correlated with error (ρ=-0.60, p<.001) Figure 4. Conclusions: This study shows that the iphone is not yet a valid instrument across all speeds, but the potential is there. Further research is needed to determine if it is valid is real world situations.
3 Introduction In 2007, the American College of Sports Medicine (ACSM) and the American Heart Association (AHA) released an updated recommendation for physical activity in adults ages 18 to 65 of moderate-intensity physical activity for 30 minutes 5 times a week. Moderate-intensity physical activity includes activities such as walking at speeds of 3-4 mph 1. The benefits of physical activity have been shown to reduce the number of coronary heart disease events 2, diabetes mellitus 3, as well as many other health conditions; however more and more Americans are not able to meet a basic exercise program as defined by the ACSM and the AHA 4. A useful and accessible method for addressing the barriers facing adults seeking to meet their recommended physical activity requirements is through the use of pedometers to monitor step count 5,6. Tracking step count provides evidence of satisfying the AHA-recommended amount of physical activity, and also estimation of distance traveled, speed, and intensity of physical activity 5,7,8, which can be used to help clinicians assess the level of function that their patient has. Low-cost pedometers, such as the Yamax pedometer (YAMAX Health & Sports, Inc., San Antonio, TX) or the StepWatch 3 (Orthocare Innovations, Mountlake Terrace, WA), have been shown to be clinically useful instruments to monitor and assess activity levels in adults 9. By tracking number of steps throughout a bout of physical activity, a physician can start to get ideas of the level of physical activities at home, which can be useful when diagnosing and prescribing treatment options. However, given the large assortment of commercially available pedometers, a clinician must be careful to select a device that has been validated (the degree to which a measurement accurately represents the real world) for the specific patient group of interest. This is clinically important so that healthcare providers are able to rely on these devices to measure steps while they are not with the patient.
4 Given the high percentage of individuals in the US who carry smartphones 10, smartphone manufacturers have begun integrating accelerometer-based pedometers into their devices. The clinical advantage of having a pedometer integrated into a smartphone is that many patients will already own these devices and clinicians can monitor patient physical activity without avoid incurring the additional expense of purchasing stand-alone pedometers. Importantly, the validity of smartphone-based pedometers depends on the accelerometer hardware and application software algorithm that identifies individual steps based on acceleration signals. Consequently, this creates a challenging task for researchers when validating smartphone-based pedometer systems due to the myriad application algorithms available. Another confounding factor is that new smartphones are constantly being released, making it difficult for researchers to keep up with the latest phones on the market due to constantly changing hardware and software. These challenges have resulted in a limited number of smartphone-based pedometer systems that have been assessed. Several studies have assessed the validity 4, reliability 11, or both 12 of various iphone (Apple Inc., Cupertino, CA) models and applications, to act as pedometers, and these investigations have produced mixed results due to differences in hardware and software combinations. In a study conducted by Boyce et. al. in 2012, the validity and reliability of three different iphone applications were assessed for able-bodied individuals at varying speeds (3, 6, 9 km/h) and sensitivities (i.e. the amount of force required to count a step; low, medium, high, self-calibrated). The single subject walked indoors on a treadmill and outdoors on a 1 km route with the iphone 4 attached to the midline posterior waist with a belt clip. The results of this study suggested poor validity (error of 20 steps in a 100 step trial) of the assessed applications for measuring steps at various speeds 12. Adjusting the sensitivities of the application could help improve the validity, but no one application was deemed valid and reliable for all speeds. The
5 authors suggest that this error is possibly due to either hardware or software limitations. Furthermore, the iphone used in this study is now 3 generations behind the currently available iphone 5S and does not represent the state-of-the-art technology. An investigation on the validity of the iphone 3GS in combination with a different iphone application to those assessed by Boyce et al., suggested a significant underestimation of steps (max mean error of steps not counted by the iphone over 2 minutes of walking) and weak correlations when the iphone was attached to various locations on the body (waist: r= -0.08, pocket: r= -0.05). One moderate correlation (r=.46) was found with the iphone attached to the arm 4. The authors suggest that further research is needed determine if there is a software application that is accurate or if there is a fundamental design flaw with the accelerometer in the iphone. Only one single-subject study suggested adequate validity (96% confidence interval, 4% error) of the iphone 3G using a custom application not available to the public 11, however this article has serious limitations. First, the iphone was attached to the ankle, which is not a location that is commonly used to store a smartphone. Second, the statistically power of this investigation is poor given the small sample size (n=1). To address this issue, Apple recently standardized the accelerometer hardware and software platform (M7 motion co-processor and associated application programming interfaces (APIs)) in the iphone 5S model and ios 7 operating system (released September of 2013). The M7 motion co-processor is a stand alone CPU inside the iphone 5S designed to estimate and record user activity related data, including but not limited to number of steps 13. Consequently, the number of steps is estimated by Apple s internal system (i.e., integrated accelerometer and algorithm) rather than custom-built applications, thereby limiting the sources of step count error. To date, validity (i.e., accuracy) of the M7 motion co-processor system has not been assessed. Therefore, the
6 aim of this study is to assess the concurrent validity of the iphone 5S s M7 motion coprocessor as a pedometer for able-bodied persons. To date, no research has been conducted to assess the validity of the current iphone generation technology that has been implemented to addresses previous shortcomings of this system to be used as a pedometer. The purpose of the proposed study is to assess the concurrent validity of the iphone 5S s M7 motion co-processor as a pedometer such that this system may serve as an instrument to accurately monitor step count for clinical use. The step count estimations of iphone 5S were compared to a manual count and the StepWatch 3 Activity Monitor, considered the clinical criterion ( gold ) standard for wearable activity monitors. We chose to validate the iphone to a clinical gold standard as well as a manual count to see if the results would suggest that the iphone could be a valid replacement of the StepWatch. Methods A convenience sample of able-bodied participants was recruited from the Northwestern University and Chicago-land area. Inclusion criteria required that participants be able to walk continuously for 30 meters without the use of an aid and possess no self-reported musculoskeletal and/or neurological disorders that might affect gait or balance. The StepWatch 3 has been previously validated as a pedometer in numerous populations, including able-bodied adults 14, lower limb amputations 8, stroke 15, and multiple sclerosis 16. The StepWatch is connected to a computer via a USB docking system. Using the StepWatch program version 3.2, step counts can be downloaded and saved onto the computer in the form of strides 17. Multiplying this number by two will give you the number of steps that the StepWatch counted.
7 The iphone 5s (M7 motion co-processor, ios 8.1.1, Model: NE296LL/A) was used for this study. A custom application was developed for this study which only served to collect step count in real-time (updated with each registered step) as estimated by the M7 motion co-processor during each walking trial and did not perform any postprocessing of the acceleration data. This application was initiated and terminated by pressing a radio button on the iphone screen. Figure 1a & 1b: Images of the custom created application (1a) (1b) Data was collected during a single visit from each participant, as they wore their own comfortable clothing with hip pockets. Prior to testing, participants signed the University-approved consent form and then their age, height, and weight were recorded. As there is no manufacturer recommendation for location of the iphone on the body for collection of step count, the iphone 5S was stored in the right hip pocket of
8 each participant during testing. The hip pocket was chosen because it is a common location of smartphones when stored on the person 11. Following the standard guidelines of the manufacturer, the StepWatch was programmed with each participant s height and weight and securely attached proximally to the lateral malleolus of the right ankle. Participants first stood quietly as the StepWatch and custom iphone application were activated for data collection, and then requested to walk to the end of a defined 30m straight-line path in a level carpeted hallway and stand quietly until the devices were deactivated and estimated steps were recorded. This task was performed at three self-selected speeds: comfortable, comfortably slow, as if you were window shopping without stopping, and comfortably fast without breaking into a jog. For each trial, video was collected to record the number of steps and elapsed time to walk the 30m path. Data Analysis To assess concurrent validity of the iphone system, step count as estimated by the iphone was compared to the manual count from video recordings and the StepWatch device. Average self-selected walking speed for each walking condition was determined by dividing the predetermined distance by the time required to complete the trial. For each speed condition, Spearman s correlation analyses were conducted to assess the strength of correlation between measurements. A correlation coefficient (ρ) of was considered a weak correlation, was considered a moderate correlation, and was considered a strong correlation 18. Bland-Altman graphs were also constructed for each speed condition to assess the presence of fixed and/or proportional bias of the iphone measurements and determine the 95% confidence limits. A one sample t-test was used to assess if the mean error was significantly different than zero (i.e., fixed bias) and Spearman s correlation analysis was used to estimate the strength of correlation between measure error and average (i.e., proportional bias).
9 Finally, to determine the relationship between walking speed and iphone accuracy, a Spearman s correlation analysis and best fit curve (with weighted error to account for outliers) was applied to the absolute manual count and iphone measurement error and walking speed across all participants and conditions. The critical α was set at 0.05 and given the multiple speed conditions per assessment, a Bonferroni correction was used to account for the family-wise Type I error rate, lowering the critical α to Statistical analyses were conducted using SPSS (IBM, Armonk, NY) and curve fitting was conducted using the curve fitting toolbox in Matlab (Mathworks, Natick, MA). Results Data were collected on twenty participants (10 male, 10 female, 28±5 years of age, 1.71±.14 meters tall, 74.8±21.2 kg). The average normal, slow, and fast walking speed was 1.33±1SD m/s 0.95±1SD m/s, and 1.77±1SD m/s. The Bland-Altman graphs for the comparison of iphone to manual count for the selected speeds suggest that no fixed or proportional bias was present for normal and fast speeds, but a fixed bias of 8 steps (p=0.015) and a strong correlation between mean and error (ρ=0.761, p<.001) was present for the slow speed Figure 2. The Bland-Altman graphs for the comparison of the StepWatch to manual count for the selected speeds suggest that no fixed or proportional bias was present for fast speed, but a fixed bias of steps (p=.023), a proportional bias for slow speed, and a strong correlation between mean and error for slow (ρ=0.796, p<.001) and fast (ρ=0.911, p<.001) speeds Figure 3. The Bland-Altman graphs for the comparison of the iphone to the StepWatch for the selected speeds suggest that no fixed or proportional bias for normal and fast speeds, but a fixed bias of 8.4 steps (p=.029), a proportional bias of (p=.003) for slow speed, and a strong correlation between mean and error for fast speeds (ρ=0.733, p<.001) Figure 4.
10 Absolute manual count and iphone measurement error versus walking speed is displayed in Figure 5. Speed was strongly correlated with error (ρ=-0.60, p<.001), and this relationship was best fit with a power function. The equation for this best fit function is f(x) = 16.8*x ( (-2.718)), r 2 = 0.607, and adjusted r 2 = Table 1: Spearman's Correlation Analysis Measures for Correlation Speed Condition Spearman s ρ p-value Slow Manual-iPhone Normal Fast 0.83 <0.001 Slow <0.001 Manual-StepWatch Normal Fast <0.001 Slow StepWatch-iPhone Normal Fast <0.001
11 Figure 2: Manual count / iphone Bland-Altman plots for normal (2a), slow (2b), and fast (2c) walking speeds. (2a) (2b) (2c)
12 Figure 3: Manual count / StepWatch Bland-Altman plots for normal (3a), slow (3b), and fast (3c) walking speeds. (3a) (3b) (3c)
13 Figure 4: StepWatch count / iphone Bland-Altman plots for normal (4a), slow (4b), and fast (4c) walking speeds. (4a) (4b) (4c)
14 Figure 5: Walking speed versus error between manual step count and iphone step count.
15 Discussion In this study we show that the iphone as a step counter in an able body population is feasible, however there are still inherent issues with it that limits its use in a clinical population. This article agrees with similar articles in that the iphone is not yet a valid tool for count step at all speeds 4,12. As speed increases, the iphone gets more and more accurate as seen by the correlation between error and speed (ρ=-0.597). A negative correlation indicates that as the speed decreases, error increases. This is likely due to the decreasing forces through the iphone as the speed decreases. Compounded upon that, Bland-Altman graphs indicate a fixed and proportional bias at the slowest speeds Figure 3a. This could indicate an issue with the accuracy of the hardware inside the device or some error in the algorithm that calculates steps at slower speeds. Using the iphone as a step counter in a clinical population would be difficult as pathologies that slow walking speed would lead to a more inaccurate step count. However, clinicians may be able to use it as a convenient tool to get a rough idea as to the mobility of the patient on a daily basis. Increasing error with decreasing speed can also be partially explained by the location of the iphone on the body. We chose to place the iphone in the right hip pocket instead of attaching it to one of the ankles, as the StepWatch is attached. The front pocket is a much more common location for the iphone in the real world, however there are much larger accelerations going through the ankle joint than the hip joint. Attaching the iphone distally on the limb would likely increase the validity of the iphone across all speeds. However, this limits its clinical use feasibility because a person will not want or be comfortable with a phone attached to their ankle at all times. The findings of this article are also important in light of the recent announcement made by Apple to allow for researchers to use the iphone as a tool to anonymously collet research data from its users. As researchers start to possibly use this information
16 for clinical decisions, further validity and refinement of the hardware/software combination must be conducted to ensure that these decisions are based on accurate data. One finding that deviated from previous studies was the presence of a fixed bias for the StepWatch in the normal condition Figure 4a and a proportional bias in the slow condition Figure 4b. Previous literature has already validated the StepWatch without and finding of biases. These biases are more likely due to some methodological error rather than an inherent error in the StepWatch system. In review of the data, the StepWatch program may not have always been programmed with the weight and age on every trial. Some of the StepWatch logs indicate that it was save others do not. Another possible source of error would be the subject reported information. Weight was determined by asking the subject without actually measuring it. Study Limitations Limitations of this study include a moderately small sample size. Due to the availability of the subjects, generalizability to the public is limited. This research was also conducted persons with no walking impairment, inside on a level carpeted hallway. Further research must be conducted to see if the iphone as a step counter holds up in real world situations. Also, since the writing of this paper, a newer iphone was released with newer software. Conclusions This study has shown that the iphone is not yet a valid step counter across a range of speeds. The iphone has the potential to be as shown by its validity at faster speeds. Further research must be conducted to see if the iphone is a valid instrument in real world situations and in a pathological population.
17 References 1. Haskell WL, Lee IM, Pate RR, et al. Physical activity and public health: updated recommendation for adults from the American College of Sports Medicine and the American Heart Association. Medicine and science in sports and exercise. Aug 2007;39(8): Thompson PD, Franklin BA, Balady GJ, et al. Exercise and acute cardiovascular events placing the risks into perspective: a scientific statement from the American Heart Association Council on Nutrition, Physical Activity, and Metabolism and the Council on Clinical Cardiology. Circulation. May ;115(17): Siscovick DS, Laporte RE, Newman JM. The Disease-Specific Benefits and Risks of Physical Activity and Exercise. Public Health Reports. 1985;100(2): Bergman RJ, Spellman JW, Hall ME, Bergman SM. Is there a valid app for that? Validity of a free pedometer iphone application. Journal of physical activity & health. Jul 2012;9(5): Tudor-Locke C, Williams JE, Reis JP, Pluto D. Utility of pedometers for assessing physical activity: construct validity. Sports medicine (Auckland, N.Z.). 2004;34(5): Tudor-Locke C, Williams JE, Reis JP, Pluto D. Utility of pedometers for assessing physical activity: convergent validity. Sports medicine (Auckland, N.Z.). 2002;32(12): Albert MV, McCarthy C, Valentin J, Herrmann M, Kording K, Jayaraman A. Monitoring functional capability of individuals with lower limb amputations using mobile phones. PloS one. 2013;8(6):e Coleman K, Smith D, Boone D, Joseph A, Aguila M. Step activity monitor: Long-term, continuous recording of ambulartory function. Journal of Rehabilitation Research and Development. 1999;36(1): Bassett DR, John D. Use of pedometers and accelerometers in clinical populations: validity and reliability issues. Physical Therapy Reviews. 2010;15(3): Smith A. 46% of American adults are smartphone owners. Pew Research Center's Internet & American Life Project Lemoyne R, Mastroianni T, Cozza M, Coroian C, Grundfest W. Implementation of an iphone as a wireless accelerometer for quantifying gait characteristics. Conference proceedings :... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference. 2010;2010: Boyce G, Padmasekara G, Blum M. Accuracy of Mobile Phone Pedometer Technology. Journal of Mobile Technology in Medicine. 2012;1(2): Etherington E. Apple's M7 Motion Sensing Coprocessor is the Wizard Behind the Curtain for the iphone 5S. Tech Crunch. Sept Foster R, Lanningham-Foster L, Manohar C, et al. Precision and accuracy of an ankle-worn accelerometer-based pedometer in step counting and energy expenditure. Preventive Medicine. 2005;41:
18 15. Mudge S, Stott NS, Walt SE. Criterion validity of the StepWatch Activity Monitor as a measure of walking activity in patients after stroke. Archives of physical medicine and rehabilitation. Dec 2007;88(12): Schmidt AL, Pennypacker ML, Thrush AH, Leiper CI, Craik RL. Validity of the StepWatch Step Activity Monitor: preliminary findings for use in persons with Parkinson disease and multiple sclerosis. Journal of geriatric physical therapy (2001). Jan-Mar 2011;34(1): StepWatch USB Docking Station 3.1 and Activity Monitor SW1001/SW1002 User Manual. Orthocare Innovations. 2012: Dancey C, Redy J. Statistics without Maths for Psychology: using SPSS for Windows. London: Prentice Hall; 2004.
HHS Public Access Author manuscript Int J Cardiol. Author manuscript; available in PMC 2016 April 15.
FITBIT : AN ACCURATE AND RELIABLE DEVICE FOR WIRELESS PHYSICAL ACTIVITY TRACKING Keith M. Diaz 1, David J. Krupka 1, Melinda J Chang 1, James Peacock 1, Yao Ma 2, Jeff Goldsmith 2, Joseph E. Schwartz 1,
More informationJEPonline Journal of Exercise Physiologyonline
Walking Technique and Estimated VO 2 max Values 21 JEPonline Journal of Exercise Physiologyonline Official Journal of The American Society of Exercise Physiologists (ASEP) ISSN 1097-9751 An International
More informationTest-Retest Reliability of the StepWatch Activity Monitor Outputs in Individuals
Test-Retest Reliability of the StepWatch Activity Monitor Outputs in Individuals with Chronic Stroke Suzie Mudge, MHSc; N. Susan Stott, PhD Department of Surgery, University of Auckland Address for correspondence:
More informationValidity of Four Activity Monitors during Controlled and Free-Living Conditions
Illinois State University ISU ReD: Research and edata Theses and Dissertations 8-27-2013 Validity of Four Activity Monitors during Controlled and Free-Living Conditions Joey Lee Illinois State University,
More informationClinical Study Synopsis
Clinical Study Synopsis This Clinical Study Synopsis is provided for patients and healthcare professionals to increase the transparency of Bayer's clinical research. This document is not intended to replace
More informationEffects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled Condition
Received: May., 011 Accepted: Jul. 8, 011 Published online: Jul. 5, 011 Original Article Effects of Age and Body Mass Index on Accuracy of Simple Moderate Vigorous Physical Activity Monitor Under Controlled
More informationStride October 20, 2017
Preliminary Design Review Stride October 20, 2017 Advisor: ProfessorTessier Hollot 1 Advisor : Professor Group Members Richie Hartnett CSE Jarred Penney EE Advisor Prof. Tessier Joe Menzie CSE Jack Higgins
More informationETB Pegasus equipment was used in the following paper
INNOVATIVE MOTION PRODUCTS ETB Pegasus equipment was used in the following paper Validation of a Novel Accelerometer-GPS system for measuring stride characteristics in galloping horses JRJ Naylor and DJ
More informationSTROKE IS THE MOST COMMON cause of severe disability
1710 ORIGINAL ARTICLE Criterion Validity of the StepWatch Activity Monitor as a Measure of Walking Activity in Patients After Stroke Suzie Mudge, MHSc, N. Susan Stott, PhD, Sharon E. Walt, PhD ABSTRACT.
More informationValidity of the StepWatch. Criterion validity of the StepWatch Activity Monitor as a measure of walking. activity in individuals following stroke.
1 Validity of the StepWatch 2 3 4 Criterion validity of the StepWatch Activity Monitor as a measure of walking activity in individuals following stroke. 5 1 6 7 Criterion validity of the StepWatch Activity
More informationKey words: biomechanics, injury, technique, measurement, strength, evaluation
Becker, T., & Havriluk, R. (2006). Bilateral and anterior-posterior muscular imbalances in swimmers. In J. P. Vilas-Boas, F. Alves, A. Marques (Eds.), Biomechanics and Medicine in Swimming X. Portuguese
More informationUsing Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking
Technical Note Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking JEFF MONTES 1, TORI M. STONE 1, JACOB W. MANNING 2, DAMON MCCUNE 1, DEBRA K. TACAD 1, JOHN C. YOUNG 1, MARK
More informationSalisbury District Hospital
The Effectiveness of Peroneal Nerve Functional Electrical STimulation (FES) for the Reduction of Bradykinesia in Parkinson s Disease: A Pragmatic Two Site Feasibility Study for a Single Blinded Randomised
More informationAPPROACH RUN VELOCITIES OF FEMALE POLE VAULTERS
APPROACH RUN VELOCITIES OF FEMALE POLE VAULTERS Peter M. McGinnis, Physical Education Department, SUNY College at Cortland, Cortland, New York INTRODUCTION Running speed is an important determinant of
More informationVideo Based Accurate Step Counting for Treadmills
Proceedings Video Based Accurate Step Counting for Treadmills Qingkai Zhen, Yongqing Liu, Qi Hu and Qi Chen * Sport Engineering Center, China Institute of Sport Science, Beijing 100061, China; zhenqingkai@ciss.cn
More informationIs lung capacity affected by smoking, sport, height or gender. Table of contents
Sample project This Maths Studies project has been graded by a moderator. As you read through it, you will see comments from the moderator in boxes like this: At the end of the sample project is a summary
More informationMobility Detection Using Everyday GSM Traces
Mobility Detection Using Everyday GSM Traces Timothy Sohn et al Philip Cootey pcootey@wpi.edu (03/22/2011) Mobility Detection High level activity discerned from course Grained GSM Data provides immediate
More informationTHE INFLUENCE OF SLOW RECOVERY INSOLE ON PLANTAR PRESSURE AND CONTACT AREA DURING WALKING
March 12, 2015 5:39:44pm WSPC/170-JMMB 1540005 ISSN: 0219-51942nd Reading Journal of Mechanics in Medicine and Biology Vol. 15, No. 2 (2015) 1540005 (6 pages) c World Scientific Publishing Company DOI:
More informationPOWER Quantifying Correction Curve Uncertainty Through Empirical Methods
Proceedings of the ASME 2014 Power Conference POWER2014 July 28-31, 2014, Baltimore, Maryland, USA POWER2014-32187 Quantifying Correction Curve Uncertainty Through Empirical Methods ABSTRACT Christopher
More informationWalk-O-Meter User Manual
Walk-O-Meter User Manual For BlackBerry Z10 and Q10 Version 2 Date 2013-09-26 1 Thank you for purchasing the Walk-O-Meter App from Cellimagine LLC. Walk-O-Meter pedometer app for your Z10 is the ultimate
More informationHealth & Fitness Journal
Health & Fitness Journal of Canada Copyright 2012 The Authors. Journal Compilation Copyright 2012 Health & Fitness Program of BC Volume 5 December 30, 2012 Number 4! ORIGINAL!ARTICLE! Is!this!Bit!Fit?!Measuring!the!Quality!of!the!FitBit!StepACounter!
More informationABSTRACT AUTHOR. Kinematic Analysis of the Women's 400m Hurdles. by Kenny Guex. he women's 400m hurdles is a relatively
Study Kinematic Analysis of the Women's 400m Hurdles by IAAF 27:1/2; 41-51, 2012 by Kenny Guex ABSTRACT The women's 400m hurdles is a relatively new discipline and a complex event that cannot be approached
More informationSontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004
Sontek RiverSurveyor Test Plan Prepared by David S. Mueller, OSW February 20, 2004 INTRODUCTION Sontek/YSI has introduced new firmware and software for their RiverSurveyor product line. Firmware changes
More informationWORLD SCIENTIFIC CONGRESS OF GOLF. ST. ANDREWS, SCOTLAND TH JULY 2002 SCIENCE AND GOLF IV PROCEEDINGS OF THE WORLD SCIENTIFIC CONGRESS OF GOLF
WORLD SCIENTIFIC CONGRESS OF GOLF. ST. ANDREWS, SCOTLAND 22-26 TH JULY 2002 SCIENCE AND GOLF IV PROCEEDINGS OF THE WORLD SCIENTIFIC CONGRESS OF GOLF EDITED BY ERIC THAIN CHAPTER 47; P531-538 AN INVESTIGATION
More informationAnalysis of Acceleration Value based on the Location of the Accelerometer
Analysis of Acceleration Value based on the Location of the Accelerometer Shin-Hyeong Choi Abstract Physical activity is essential for human health maintenance. We investigate the effects of acceleration
More informationINFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS. Melissa Dock
INFLUENCE OF PEDOMETER TILT ANGLE ON STEP COUNTING VALIDITY DURING CONTROLLED TREADMILL WALKING TRIALS by Melissa Dock A thesis submitted in partial fulfillment of the requirements for the degree of Master
More informationACTIVITY MONITORING SYSTEM
ACTIVITY MONITORING SYSTEM Hardik Shah 1, Mohit Srivastava 2, Sankarshan Shukla 3, Dr. Mita Paunwala 4 Student, Electronics and Communication, CKPCET, Surat, Gujarat, India 1 Student, Electronics and Communication,
More informationFigure 1 betois (bending torsion insole system) system with five measuring points and A/D- converter.
Bending and Torsional Moments - A new measuring system for gait analysis Nora Dawin & Annette Kerkhoff & Klaus Peikenkamp, University of Applied Sciences Münster, Germany Abstract The Laboratory of Biomechanics
More informationReliability of Scores From Physical Activity Monitors in Adults With Multiple Sclerosis
ADAPTED PHYSICAL ACTIVITY QUARTERLY, 2007, 24, 245-253 2007 Human Kinetics, Inc. Reliability of Scores From Physical Activity Monitors in Adults With Multiple Sclerosis Robert W. Motl, Weimo Zhu, Youngsik
More informationValidation of Measurements from a ZephIR Lidar
Validation of Measurements from a ZephIR Lidar Peter Argyle, Simon Watson CREST, Loughborough University, Loughborough, United Kingdom p.argyle@lboro.ac.uk INTRODUCTION Wind farm construction projects
More informationINTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING
INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING Joseph P. Hunter 1, Robert N. Marshall 1,, and Peter J. McNair 3 1 Department of Sport and Exercise Science, The University of Auckland, Auckland,
More informationTraffic Parameter Methods for Surrogate Safety Comparative Study of Three Non-Intrusive Sensor Technologies
Traffic Parameter Methods for Surrogate Safety Comparative Study of Three Non-Intrusive Sensor Technologies CARSP 2015 Collision Prediction and Prevention Approaches Joshua Stipancic 2/32 Acknowledgements
More informationObjective Physical Activity Monitoring for Health-Related Research: A Discussion of Methods, Deployments, and Data Presentations
Objective Physical Activity Monitoring for Health-Related Research: A Discussion of Methods, Deployments, and Data Presentations John M. Schuna Jr., PhD School of Biological and Population Health Sciences
More informationsave percentages? (Name) (University)
1 IB Maths Essay: What is the correlation between the height of football players and their save percentages? (Name) (University) Table of Contents Raw Data for Analysis...3 Table 1: Raw Data...3 Rationale
More informationGROUND REACTION FORCE DOMINANT VERSUS NON-DOMINANT SINGLE LEG STEP OFF
GROUND REACTION FORCE DOMINANT VERSUS NON-DOMINANT SINGLE LEG STEP OFF Sara Gharabaghli, Rebecca Krogstad, Sara Lynch, Sofia Saavedra, and Tamara Wright California State University, San Marcos, San Marcos,
More informationG-EOL. Discover the simplicity of gait therapy intended for daily use
G-EOL Discover the simplicity of gait therapy intended for daily use Reha Technology a passion for robotic-assisted gait therapy For over 10 years, Reha Technology has been successfully developing innovative,
More informationMonitoring Daily Energy Expenditure using a 3-Axis Accelerometer with a Low-Power Microprocessor
Monitoring Daily Energy Expenditure using a 3-Axis Accelerometer with a Low-Power Microprocessor Yoshihiro Kawahara, Nanami Ryu, Tohru Asami Graduate School of Information Science and Technology The University
More informationCenter of Mass Acceleration as a Surrogate for Force Production After Spinal Cord Injury Effects of Inclined Treadmill Walking
Center of Mass Acceleration as a Surrogate for Force Production After Spinal Cord Injury Effects of Inclined Treadmill Walking Mark G. Bowden, PhD, PT Research Health Scientist, Ralph H. Johnson VA Medical
More informationHealth + Track Mobile Application using Accelerometer and Gyroscope
Health + Track Mobile Application using Accelerometer and Gyroscope Abhishek S Velankar avelank1@binghamton.edu Tushit Jain tjain3@binghamton.edu Pelin Gullu pgullu1@binghamton.edu ABSTRACT As we live
More informationTowards determining absolute velocity of freestyle swimming using 3-axis accelerometers
Towards determining absolute velocity of freestyle swimming using 3-axis accelerometers Author Stamm, Andy, Thiel, David, Burkett, Brendan, James, Daniel Published 2011 Journal Title Procedia Engineering
More informationbespoke In general health and rehabilitation Breath-by-breath multi-functional respiratory gas analyser In human performance
Introduction Expired Gas Analysis or indirect calorimetry, can be used to measure ventilation and the fractions of oxygen and carbon dioxide in expired air. From these measurements, the body's oxygen consumption
More informationValidation of a patient activity monitor to quantify ambulatory activity in an amputee population
Prosthetics and Orthotics International June 2007; 31(2): 157 166 Validation of a patient activity monitor to quantify ambulatory activity in an amputee population N. RAMSTRAND & K.-Å. NILSSON Department
More informationGait Analyser. Description of Walking Performance
Gait Analyser Description of Walking Performance This brochure will help you to understand clearly the parameters described in the report of the Gait Analyser, provide you with tips to implement the walking
More informationEN-MOTION TREADMILL. EN-Motion: the ultimate PHYSIO treadmill
The EN-Motion treadmill is a valuable asset to the physiotherapy and rehabilitation world. An innovative treadmill, ideal for physiotherapy and rehabilitation purposes. EN-MOTION GETS THE WORLD MOVING
More informationStep Counting Investigation with Smartphone Sensors
Rochester Institute of Technology Department Of Computer Science FALL 2016 Step Counting Investigation with Smartphone Sensors Author: Supervisor Dr. Leon Reznik December 12, 2016 Contents 1 Introduction
More informationMedicine. Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity. A Pilot Study. Fusun Ardic, MD and Esra Göcer, MD
Medicine OBSERVATIONAL STUDY Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity A Pilot Study Fusun Ardic, MD and Esra Göcer, MD Abstract: The purpose of this study was to examine the
More informationThe Effect of a Seven Week Exercise Program on Golf Swing Performance and Musculoskeletal Screening Scores
The Effect of a Seven Week Exercise Program on Golf Swing Performance and Musculoskeletal Screening Scores 2017 Mico Hannes Olivier Bachelor of Sport Science Faculty of Health Sciences and Medicine Bond
More informationSpeedMax White Paper. Dynastream Innovations Inc. 228 River Avenue Cochrane, AB T4C 2C1. p f
SpeedMax White Paper 228 River Avenue Cochrane, AB T4C 2C1 www.dynastream.com p 403.932.9292 f 403.932.6521 1 OVERVIEW Established in 1998, has world-leading expertise in the research and development of
More informationNovel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils
86 Pet.Sci.(29)6:86-9 DOI 1.17/s12182-9-16-x Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils Ehsan Khamehchi 1, Fariborz Rashidi
More informationThe Impact of Walker Style on Gait Characteristics in Non-assistive Device Dependent older Adults
St. Catherine University SOPHIA Doctor of Physical Therapy Research Papers Physical Therapy 5-2017 The Impact of Walker Style on Gait Characteristics in Non-assistive Device Dependent older Adults Matthew
More informationWhat is the optimal design of a rocker shoe
What is the optimal design of a rocker shoe University of Salford School of Health, Sport and Rehabilitation Sciences Deutsche Sporthochschule Köln J Chapman, S Preece, C Nester, B Braunstein, P Bruggerman
More informationEvaluation of a commercially available
Loughborough University Institutional Repository Evaluation of a commercially available pedometer used to promote physical activity as part of a national programme This item was submitted to Loughborough
More informationAccuracy of a Pedometer and an Accelerometer in Women with Obesity
The Open Obesity Journal, 2012, 4, 11-17 11 Open Access Accuracy of a Pedometer and an Accelerometer in Women with Obesity Malin Wiklund *, Åsa Cider and Monika Fagevik Olsén Department of Physiotherapy
More informationAccelerometers: An Underutilized Resource in Sports Monitoring
Accelerometers: An Underutilized Resource in Sports Monitoring Author Neville, Jono, Wixted, Andrew, Rowlands, David, James, Daniel Published 2010 Conference Title Proceedings of the 2010 Sixth International
More informationiphone as a Physical Activity Measurement Platform
iphone as a Physical Activity Measurement Platform Yuichi Fujiki Compuational Physiology Lab University of Houston 4800 Calhoun Rd Houston TX, 77204, USA yfujiki@uh.edu Abstract iphone is emerging as a
More informationFall Prevention Midterm Report. Akram Alsamarae Lindsay Petku 03/09/2014 Dr. Mansoor Nasir
Fall Prevention Midterm Report Akram Alsamarae Lindsay Petku 03/09/2014 Dr. Mansoor Nasir Updates to timeline Last semester we created a timeline that included important milestones. We have narrowed down
More informationDIFFERENCE BETWEEN TAEKWONDO ROUNDHOUSE KICK EXECUTED BY THE FRONT AND BACK LEG - A BIOMECHANICAL STUDY
268 Isas 2000! Hong Kong DIFFERENCE BETWEEN TAEKWONDO ROUNDHOUSE KICK EXECUTED BY THE FRONT AND BACK LEG - A BIOMECHANICAL STUDY Pui-Wah Kong, Tze-Chung Luk and Youlian Hong The Chinese University of Hong
More informationThe overarching aim of the work presented in this thesis was to assess and
CHAPTER 7 EPILOGUE Chapter 7 The overarching aim of the work presented in this thesis was to assess and understand the effort for balance control in terms of the metabolic cost of walking in able-bodied
More informationReprocessed QuikSCAT (V04) Wind Vectors with Ku-2011 Geophysical Model Function
Reprocessed QuikSCAT (V04) Wind Vectors with Ku-2011 Geophysical Model Function Lucrezia Ricciardulli and Frank Wentz Introduction In April 2011, we reprocessed the QuikSCAT ocean wind vectors using a
More informationS-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE
S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE 1. INTRODUCTION The s-curve function allows the user to define a smooth response yet still maintain a high acceleration. In many applications
More informationGait Analysis at Your Fingertips:
Gait Analysis at Your Fingertips: Enhancing Observational Gait Analysis Using Mobile Device Technology and the Edinburgh Visual Gait Scale Jon R. Davids, MD; Shriners Hospitals for Children Northern California;
More informationSESSION ONE SESSION 1, P 4
SESSION ONE SESSION 1, P 4 Session 1A Time: 1 hour Registration Supplies: Registration forms Text/Email Registration forms Consent forms Physical Activity Assessments Name tags Welcome Supplies: Participant
More informationSafety Assessment of Installing Traffic Signals at High-Speed Expressway Intersections
Safety Assessment of Installing Traffic Signals at High-Speed Expressway Intersections Todd Knox Center for Transportation Research and Education Iowa State University 2901 South Loop Drive, Suite 3100
More informationMonitor Unit Verification for Small Fields
Monitor Unit Verification for Small Fields Patrick Higgins, Ph.D University of Minnesota Department of Radiation Oncology October 10, 2013 The Issues: How do we verify the monitor units calculated by the
More informationValidity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device
Journal of Sports Science 5 (2017) 235-241 doi: 10.17265/2332-7839/2017.05.001 D DAVID PUBLISHING Validity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device Randolph
More informationWalk - Run Activity --An S and P Wave Travel Time Simulation ( S minus P Earthquake Location Method)
Walk - Run Activity --An S and P Wave Travel Time Simulation ( S minus P Earthquake Location Method) L. W. Braile and S. J. Braile (June, 2000) braile@purdue.edu http://web.ics.purdue.edu/~braile Walk
More informationAmbulatory monitoring of gait quality with wearable inertial sensors
Ambulatory monitoring of gait quality with wearable inertial sensors Dr. Philippe Terrier, PhD June 2016 Summary 1. Why? Reasons for measuring gait in real life conditions 2. What? Real-life assessment
More informationCONSUMER MODEL INSTALLATION GUIDE
CONSUMER MODEL INSTALLATION GUIDE System requirements Windows System Requirements To use your TOMI and its software, your system should have: A Microsoft Windows compatible PC with a Pentium IV processor
More informationSprint Hurdles SPRINT HURDLE RACES: A KINEMATIC ANALYSIS
Sprint Hurdles SPRINT HURDLE RACES: A KINEMATIC ANALYSIS By Pierre-Jean Vazel, December 2011 In order to prescribe the most effective training possible it is important for coaches to have a sound understanding
More informationWIND DATA REPORT. Bourne Water District
WIND DATA REPORT Bourne Water District July to September 2010 Prepared for Massachusetts Clean Energy Center 55 Summer Street, 9th Floor Boston, MA 02110 by Dylan Chase James F. Manwell Utama Abdulwahid
More informationUSER GUIDE USER GUIDE
1 TABLE OF CONTENTS GETTING STARTED 2 Included in the box 2 Compatible smartphones 2 Accessories: 2 Download Mobitee and PIQ application 2 GET STARTED WITH MOBITEE AND PIQ 3 Create your Account and Login
More informationThis study investigated the amount of physical activity that occurred during
Abstract This study investigated the amount of physical activity that occurred during work and total waking hours in a sample of New Zealand professional office workers. Data were collected over three
More informationBAUKJE DIJKSTRA, WIEBREN ZIJLSTRA, ERIK SCHERDER, YVO KAMSMA. Abstract. Introduction
Age and Ageing 28; 37: 436 441 doi:.93/ageing/afn97 Published electronically 16 May 28 The Author 28. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved.
More informationEXAMINING THE RELABILITY AND VALIDITY OF THE FITBIT CHARGE 2 TECHNOLOGY FOR HEART RATE DURING TREADMILL EXERCISE
EXAMINING THE RELABILITY AND VALIDITY OF THE FITBIT CHARGE 2 TECHNOLOGY FOR HEART RATE DURING TREADMILL EXERCISE Mahalie Hargis 1, Robert O. Powell 1, and Suzanne M. Konz 1 Marshall University, Huntington,
More informationTriage Using Telemedicine: Advancements in Prehospital Stroke Care
Triage Using Telemedicine: Advancements in Prehospital Stroke Care Prasanthi Govindarajan MD, MAS Associate Professor of Emergency Medicine Stanford University Medical Center Disclosures American Heart/Stroke
More informationKnee Kinematic Improvement after Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method
Iranian Rehabilitation Journal, Vol. 11, No. 18, October 2013 Original Article Knee Kinematic Improvement after Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method Hassan Sarailoo
More informationThe Chartered Society of Physiotherapy Charitable Trust RESEARCH STRATEGY CSP Charitable Trust Registered Charity No.
The Chartered Society of Physiotherapy Charitable Trust RESEARCH STRATEGY 2015-2019 CSP Charitable Trust Registered Charity No. 279882 Contents Foreword 1 Foreword 2 2 Introduction 2 3 Where are we now?
More informationRUNNING. Normal Running 10/10/2016. Reliability and Concurrent Validity of a 2D Observational Gait Analysis Tool
Reliability and Concurrent Validity of a 2D Observational Gait Analysis Tool Kevin Yu, SPT Robert Wayner, PT, DPT Jennifer Smith, PT, DPT RUNNING Stance Phase (Single Limb Support) Initial Contact / Foot
More informationAutoGait: A Mobile Platform that Accurately Estimates the Distance Walked
AutoGait: A Mobile Platform that Accurately Estimates the Distance Walked -Written By- Dae-Ki Cho, Min Mun, Uichin Lee, William J. Kaiser, Mario Gerla -Presented By- Scott Mitchell CS Department Problem
More informationAnalysis of Foot Pressure Variation with Change in Stride Length
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-853, p-issn: 2279-861.Volume 13, Issue 1 Ver. IV (Oct. 214), PP 46-51 Dr. Charudatta V. Shinde, M.S. MCh ( Orthopaedics ), Dr. Weijie
More informationBIODEX. New Jersey clinic enhances patient rehab using music-assisted gait training CASESTUDY. Body In Balance Physical Therapy and Fitness Center
CASESTUDY New Jersey clinic enhances patient rehab using music-assisted gait training Body In Balance Physical Therapy and Fitness Center BIODEX Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New
More informationLifeBeat should be worn during daytime as well as night time as it can record activity levels as well as sleep patterns.
myhealth FAQ V1.0.5 GENERAL What is LifeBeat Stress Tracker? LifeBeat Stress Tracker is a system that lets you track your activity, sleep, and especially your various stress levels, so that you can improve
More informationUNIVERSITY OF WATERLOO
UNIVERSITY OF WATERLOO Department of Chemical Engineering ChE 524 Process Control Laboratory Instruction Manual January, 2001 Revised: May, 2009 1 Experiment # 2 - Double Pipe Heat Exchanger Experimental
More informationA modified axillary crutch for lower limb amputees
Research papers A modified axillary crutch for lower limb amputees KTD Kahaduwa 1, CDA Weerasiriwardane 2, SM Wijeyaratne 1 1 University Surgical Unit, Faculty of Medicine, Colombo, Sri Lanka 2 Navy Research
More informationMIE Medical Research Ltd Digital Analyser Pinch/Grip Instruction Manual
Doc 116-03 Copyright 1998-2004 MIE Medical Research Ltd Getting Started MIE Medical Research Ltd Unpack your Digital Analyser and check that the following components are present: 1 x Digital Analyser
More informationRUNNING SHOE STIFFNESS: THE EFFECT ON WALKING GAIT
RUNNING SHOE STIFFNESS: THE EFFECT ON WALKING GAIT Stephen N Stanley, Peter J M c Nair, Angela G Walker, & Robert N Marshall Auckland Institute of Technology, Auckland, New Zealand University of Auckland,
More informationSandra Nutter, MPH James Sallis, PhD Gregory J Norman, PhD Sherry Ryan, PhD Kevin Patrick, MD, MS
Objectively Measured Environmental Correlates of Adolescent Physical Activity Sandra Nutter, MPH James Sallis, PhD Gregory J Norman, PhD Sherry Ryan, PhD Kevin Patrick, MD, MS San Diego State University
More informationSpatial Methods for Road Course Measurement
Page 1 of 10 CurtinSearch Curtin Site Index Contact Details Links LASCAN Spatial Sciences WA Centre for Geodesy COURSE MEASUREMENT This page is a summary of results of some of the research we have recently
More informationDesign of Monitoring System Step Walking With MPU6050 Sensor Based Android
Journal Of Informatics, Network, and Computer Science Vol : 1, No : 1, November 2016, Halaman : 1 8 ISSN : 2541-5123 DOI Link : https://doi.org/10.21070/joincs.v1i1.799 Design of Monitoring System Step
More information2015, Vol. 27, No. 1, ISSN (Print) Eirik Haukali & Leif Inge Tjelta* University of Stavanger, Norway. Abstract
International Journal of Applied Sports Sciences ISSN 2233-7946 (Online) 2015, Vol. 27, No. 1, 26-32. ISSN 1598-2939 (Print) c Korea Institute of Sport Science http://www.sports.re.kr/eng/05publication/callforpaper.jsp
More informationTension Cracks. Topics Covered. Tension crack boundaries Tension crack depth Query slice data Thrust line Sensitivity analysis.
Tension Cracks 16-1 Tension Cracks In slope stability analyses with cohesive soils, tension forces may be observed in the upper part of the slope. In general, soils cannot support tension so the results
More informationAdd this important safety precaution to your normal laboratory procedures:
Student Activity Worksheet Speed and Velocity Are You Speeding? Driving Question What is speed and how is it related to velocity? Materials and Equipment For each student or group: Data collection system
More information1 INEGI Instituto de Engenharia Mecânica e Gestão Industrial, Porto, Portugal, FEUP Faculdade de Engenharia,
REGISTRATION BETWEEN DATA FROM VISUAL SENSORS AND FORCE PLATFORM IN GAIT EVENT DETECTION Sousa, Daniela Sofia S., Tavares, João Manuel R. S., Correia, Miguel V., Mendes, Emília, Veloso, António 4, Silva,
More informationQueue analysis for the toll station of the Öresund fixed link. Pontus Matstoms *
Queue analysis for the toll station of the Öresund fixed link Pontus Matstoms * Abstract A new simulation model for queue and capacity analysis of a toll station is presented. The model and its software
More informationTechnical Report. Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired Function
Technical Report Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired Function Kristin Taraldsen, Torunn Askim, Olav Sletvold, Elin Kristin Einarsen, Karianne
More informationIn addition to reading this assignment, also read Appendices A and B.
1 Kinematics I Introduction In addition to reading this assignment, also read Appendices A and B. We will be using a motion detector to track the positions of objects with time in several lab exercises
More informationDenny Wells, Jacqueline Alderson, Kane Middleton and Cyril Donnelly
11:45 am-12:00 pm Denny Wells. Assessing the accuracy of inverse kinematics in OpenSim to estimate elbow flexionextension during cricket bowling: Maintaining the rigid linked assumption. (201) ASSESSING
More information10-CM Field Testing Project
ICD-10 10-CM Field Testing Project National Committee on Vital and Health Statistics September 23, 2003 Nelly Leon-Chisen, RHIA American Hospital Association Sue Prophet-Bowman, RHIA American Health Information
More informationIDeA Competition Report. Electronic Swimming Coach (ESC) for. Athletes who are Visually Impaired
IDeA Competition Report Electronic Swimming Coach (ESC) for Athletes who are Visually Impaired Project Carried Out Under: The Department of Systems and Computer Engineering Carleton University Supervisor
More informationSPRINTING CHARACTERISTICS OF WOMEN S 100 METER FINALS AT THE IAAF WORLD CHAMPIONSHOPS DAEGU 2011
9:30-9:45 am Sang-Kyoon Park. Sprinting characteristics of women's 100 meter finals at the IAAF world championships Daegu 2011. (228) SPRINTING CHARACTERISTICS OF WOMEN S 100 METER FINALS AT THE IAAF WORLD
More information