1 Brownie s M A R I N E G R O U P Commercial Series NMCS-7.5 NMCS-10 NMCS-20 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx
2 This information is believed to be accurate by Brownie s Marine Group as of it s date of publication, but Brownie s offers NO WARRANTY regarding the accuracy, or continuing accuracy, of the information set forth herein. Brownie s shall not be liable for inaccuracies in, or consequences resulting from, your use of this information. All information supplied is in connection with sales of Brownie s products, and is thus subject to Brownie s standard terms and conditions of sale. Brownie s reserves the right to change this information and has no obligation to update these materials. This information is Copyright 2013 by Brownie s Marine Group, and Brownie s reserves to itself all rights to this publication. Brownie s customers have no right to reproduce, rewrite, modify, license or permit anyone else s use of this information, without the express written permission of Brownie s Marine Group. 2 11/13
3 Table of Contents Chapter 1: Introduction How to Use this Manual Manual Safety Notices Components of a NitroxMaker TM System System Requirements Installation...7 Chapter 2: Operations General Pre-Start Checks Initial System Start-up Procedure Controlling the Nitrox Mixture Recalibrating the Oxygen Analyzer Shutdown NitroxMaker TM System...11 NMCS Views...12 NitroxMaker TM Commercial Series NitroxMaker TM Commercial Series NitroxMaker TM Commercial Series NitroxMaker TM Commercial Series Compressed Air Filters...20 Specifications...21 Log Pages
4 WARNING This Instruction Manual and Replacement Parts List contains safety information and instructions for the NitroxMaker System and Nitrox Membrane. You must read, understand and follow all safety precautions and instructions. CHAPTER 1: INTRODUCTION 1.1 How To Use This Manual This manual contains the operating and maintenance instructions for the Brownie s Third Lung product(s) listed on the front cover. All instructions in this manual should be observed and carried out as written to prevent damage or premature wear to the product or the equipment served by it. If your unit is equipped with nonstandard accessories and/or options, supplemental information is normally included in other documentation; i.e. OEM Manuals or additional Brownie s Third Lung Manuals. While every effort is made to ensure the accuracy of the information contained in this manual, Brownie s Third Lung will not, under any circumstances be held accountable for any inaccuracies or the consequences thereof. 1.2 Manual Safety Notices Important instructions concerning the endangerment of personnel, technical safety or operator safety will be specially emphasized in this manual by placing the information in the following types of safety notices. DANGER DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This is limited to the most extreme situations. WARNING WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. NOTE NOTE advise of technical requirements that require particular attention by the operator or the maintenance technician for proper maintenance and utilization of the equipment. 4
5 5
6 1.4 System Requirements Grade E air is the quality/purity standard you should already be pumping for use as breathing air according to the CGA standards. Please make sure you exercise extreme caution regarding the maintenance of the filter/purification system to ensure this standard is maintained at all times. This is not only critical for the well-being of divers, but also to that of the NitroxMaker TM components. If there is doubt in the quality of the air being compressed please discontinue use of the NitroxMaker TM system and call Brownie s Third Lung for service and an Air Quality Test. Definition Grade E Air: O2%: CO2: 1000 ppm CO: 10 ppm Hydrocarbons: 25 ppm Water: 67 ppm Dew Point: -50 F Oil & Particles: 5 mg/m3 Odor: none 6
7 1.5 Installation Place/install the machinery according to the guidelines in the Kaeser compressor manual. Ensure you will have adequate space to: -manipulate the machinery controls, including the Receiver IN & OUT valves -manipulate the nitrox production controls -change the LP filter cartridges -remove service panels and service the machinery Verify LP filter cartridges are installed in LP Filter Array canisters Connect condensate drain line to drain port on the dryer. Route the drain line to a suitable location. Make electric connections according to the Kaeser manual. Install Nitrogen Waste Gas Lines. The Waste Port Regulators include exposed barb fittings designed to accept ½ inch ID hose. Use only new hose in good condition, without holes, breaks or cuts that could leak waste gas into the operational area of the compressor. Route the Nitrogen Waste Gas Lines to a suitable location. Verify the hose is not kinked or crushed to reduce the flow of waste gas. DANGER INGESTION OF NITROGEN WASTE GAS CAN CAUSE INJURY OR DEATH. Make sure waste gas lines are routed to a well ventilated location (outside) where accumulation or ingestion of the nitrogen waste gas will not occur. Install Nitrox Transfer Hose The Nitrox Transfer hose carries nitrox mix from the NitroxMaker to the intake port of the high-pressure compressor. Use only non-collapsible hose suitable for breathing air applications. Hose sizes: 1.5 inch ID NMCS7.5 & NMCS inch ID NMCS20 & NMCS30 Make sure hose ends have clean edge cuts, without loose shavings, dust or other foreign matter. Install the nitrox sampling line (protruding from the end of the Mixing Tube) as far as possible into the Nitrox Transfer Hose. Blowing the sampling line with compressed air will help distribute it along the interior dimension of the Nitrox Transfer Hose. Install the Nitrox Transfer Hose onto the output fitting at the base of the Mixing Tube and secure with a hose clamp. Install the Nitrox Transfer Hose onto the intake fitting of the high-pressure compressor and secure with a hose clamp. Install HP Compressor Sampling Regulator and hose A sampling regulator assembly is included to route the output gas from the high-pressure compressor back to the NitroxMaker Control Panel. Install the sampling regulator assembly downstream of the purification filtration system if possible. Connect the hose from the Tankfill Analyzer Selector Valve to the sampling regulator assembly. When the sampling regulator valve is open, low-pressure gas will be routed to the Tankfill Analyzer. 7
8 CHAPTER 2: OPERATIONS 2.1 General The safety instructions applicable to this product are contained in the Appendix. They must be read, understood and complied with prior to operating the product. All system checks, start-up and shut down procedures are based on standard system configurations. Components may vary. 2.2 Pre-start Checks High-Pressure Compressor Check the condition and safe operating instructions of the high-pressure compressor to which the nitrox mix will be supplied. Refer to the high-pressure compressor operator s manual for any technical assistance. Specifically check the following items: -Compressor oil level -Condition of intake and purification filter(s) -Check for excessive moisture or carbon monoxide if an indicator is present in the system -Verify the HP compressor sampling regulator control valve is in the OPEN position. NitroxMaker Commercial Series Follow all operating instructions in the operator s manual for the associated Kaeser air system. -Verify the nitrox supply hose is secured to the output of the nitrox mixing tube on the NitroxMaker. The other end should be secured to the intake of the high-pressure compressor. Verify the hose is in good condition, without holes, breaks or cuts that could compromise the gas mixture being produced. -Verify nitrogen waste line(s) are secure on the Waste Port Regulator at the base of the membrane stick(s) and that the waste lines are vented to an outside location where accumulation or ingestion of the nitrogen waste gas will not occur. DANGER INGESTION OF NITROGEN WASTE GAS CAN CAUSE INJURY OR DEATH. Make sure waste gas lines are routed to a well ventilated location (outside) where accumulation or ingestion of the nitrogen waste gas will not occur. Tanks Inspect ALL tanks to be filled: -Make sure the tanks are in good condition with no deep scratches, gouges or pitting. -The tanks must be within current hydrostatic test and Visual Inspection dates. -Do not fill empty tanks without first visually inspecting them for water intrusion. -Make sure that the valves are in good condition and not in need of service. Do not fill tanks with damaged valves. -Do not fill tanks that have been exposed to extreme heat, i.e.: tanks that have been in or near fires. Records -Add all pre-startup maintenance/inspection notations to the system log with date, hours and operator name. 8
9 2.3 Initial System Start-up Procedure 1. Verify the circuits responsible to power the machinery are on at the breaker panel. 2. Verify the Air Receiver IN and OUT valves are in the open position. Air stored under pressure in the Air Receiver will start to flow this is normal. 3. Turn on the Kaeser system according to the instructions in the Kaeser manual. Check the low-pressure filter array. The canisters have indicators to provide visual reference of the filter element remaining life. AIR MUST BE FLOWING to get an accurate reading on the indicators. Change any filter cartridges before total saturation is indicated. 4. Turn on the high-pressure compressor according to the manufacturer s instructions. The high-pressure compressor will consume the gas in the nitrox transfer hose. Allow the output of the high-pressure compressor to flow freely until the desired nitrox mix has been achieved. Failure to turn on the high-pressure compressor will cause a back-up of gas in the nitrox transfer hose. Excess gas volume will flow out through the intake air filter at the top of the mixing tube, preventing an accurate reading of the nitrox mix being produced. 5. Turn ON both gas analyzers and calibrate to AIR (20.9% oxygen) a. Turn the Selector valve to the CALIBRATE position. b. Using the control knob at the base of the FLOW METER, adjust the flow rate to 1-2 liters per minute (LPM). c. Calibrate both according to the analyzer manufacturer s instructions. Lock in the calibration when the reading is consistent at 20.9%. 6. Turn the Selector valves to the OUTPUT position. 7. Using the control knob at the base of the FLOW METER, adjust the flow rate to 1-2 liters per minute (LPM). The NITROX ANALYZER will display the oxygen percentage in the gas flowing through the nitrox transfer hose to the high-pressure compressor. The TANKFILL ANALYZER will display the oxygen percentage in the gas provided by the sampling regulator, downstream of the high-pressure compressor output. 9
10 2.4 Controlling the Nitrox Mixture Adjusting the pressure of the air supplied to the membrane sticks will change the oxygen percentage of the gas being produced. Higher pressure produces higher concentrations of oxygen. As the pressure is reduced, the percentage of oxygen will decrease as well. As you gain experience with the system, you will learn the approximate percentage you can expect for a given range of supply pressure. Keeping a log as you work with the system will provide a handy reference for later use. WARNING The performance of each membrane stick is unique. It may be possible to create nitrox mixtures with oxygen concentrations greater the 40%. DO NOT SUPPLY GAS MIXTURES WITH OXYGEN CONCENTRATIONS OVER 40% to the intake of any high-pressure compressor combustion, equipment damage or component failure may occur. Consult your high-pressure compressor manufacturer for additional information. - Turn the NITROX MIX CONTROLLER knob clockwise or counter-clockwise to adjust the pressure. - The SUPPLY PRESSURE GAUGE will indicate the gas pressure being supplied to the membrane stick(s). - Adjust the pressure in 5 psi increments. After adjusting the supply pressure, wait at least 60 seconds for the mixture change to be accurately displayed on the NITROX ANALYZER. Likewise, depending on the size and processing volume of the high-pressure compressor, you will need to wait 1-5 minutes for the mixture to work through the multiple stages of the high-pressure compressor and filtration to see an accurate reading on the TANKFILL ANALYZER. The high-pressure compressor output mixture may vary up to ±2% from the mixture displayed on the NITROX ANALYZER. 10
11 2.5 Recalibrating the Analyzer(s) While the System is Running - Recalibration should be performed any time there is an unusual discrepancy between the analyzers. - Perform steps 5, 6 and 7 in section 2.3 as necessary. 2.6 Shutting Down the NitroxMaker System - Close the Air Receiver OUT valve to stop the flow of air to the NitroxMaker system. When the receiver reaches the maximum programmed pressure, the Kaeser system will enter IDLE mode the compressor will continue to spin but air will not be produced. If air flow does not commence, the system will enter SLEEP mode to conserve power until the flow of air resumes. - Turn the Kaeser system OFF according to the instructions in the Kaeser manual. The pressure in the Air Receiver will be retained, allowing you to restart nitrox production more quickly. - Turn the high-pressure compressor OFF. - Turn the HP compressor sampling regulator control valve to the CLOSED position. The high-pressure compressor may be used WITHOUT the NitroxMaker system to fill scuba tanks or storage bottles with AIR. The high-pressure compressor will ingest the required volume through the nitrox supply hose. If the NitroxMaker system is not ON, the required volume will be supplied through the Intake Filter at the top of the Mixing Tube. 11
12 7.5 1 Compressor/Dryer Control Panel 2 3 Emergency OFF Rotary Screw Compressor 4 Dryer Electronic Demand Drain Receiver OUT Valve 11 ECO-DRAIN 12
13 Receiver Pressure Gauge 7 Air Receiver (Tank) Intake Filter 18 Membrane 17 Mixing Tube 20 6 Access Panel (Cover) Temperature Controller 21 Heater Element Receiver OUT Valve Waste Port Regulators 19 9 LP Filter Array 9 16 Supply Pressure Gauge Nitrox Mix Controller 13 Gas Analyzer 14 Flow Meter 15 Selector Valve 13
14 10 Compressor/Dryer Control Panel 1 Emergency OFF Rotary Screw Compressor Nitrox Production Control Panel Dryer Access Panel 6 Air Receiver 7 17 Membrane 12 Receiver Pressure Gauge 14
15 10 19 Waste Port Regulator 18 Intake Filter 20 Mixing Tube 21 Temperature Controller 8 LP Filter Array 20 Mixing Tube 12 Receiver OUT Valve 11 Receiver IN Valve Emergency OFF 24 Nitrox Mix Controller 16 Gas Analyzer 13 Flow Meter 14 Selector Valve 15 15
16 20 Compressor/Dryer Control Panel 1 Emergency OFF 2 Nitrox Production Control Panel 5 Rotary Screw Compressor 3 Dryer 4 Access Panel 6 7 Air Receiver LP Filter array 8 16
17 20 Supply Pressure Gauge 9 Flow Meter 14 Gas Analyzer 13 Selector Valve 15 Nitrox Mix Controller Waste Port Regulator Intake Filter 18 Mixing Tube Temperature Controller Heater Element Membrane Condensate Drain Port 23 Receiver IN Valve Receiver OUT Valve Nitrox Transfer Hose 17
18 30 Compressor/Dryer Control Panel 1 Dryer 4 3 Rotary Screw Compressor Emergency OFF 2 Nitrox Production Control Panel 5 Access Panel 6 Air Receiver 7 Receiver Pressure Gauge Receiver OUT Valve LP Filter Array 8 Receiver Out Valve 9 10 Receiver In Valve 18
19 30 13 Gas Analyzer 9 Supply Pressure Gauge 14 Flow Meters Selector Valves Nitrox Mix Controller Intake Filter 18 Waste Port Regulator 19 Mixing Tube 20 Membrane Temperature Controller Heater Element 22 Nitrox Transfer Hose 24 19
20 Compressed Air Filters Designed and developed using the latest innovations and manufacturing techniques, Kaeser filter housing are designed with larger flow areas to ensure low pressure drop and to prove easier installation, operation and maintenance. The result is consistent product quality while minimizing operating costs. Standard Features and Benefits 4 1 Delta P Slide Indicator Ensures economical operation by changing color when filter element requires replacement. Fitted as standard on filters up to 60 scfm (excluding KVA). 1 2 Color Coded Elements Allows easy identification. Elements are designed using the latest media innovations and manufacturing technology. 5 3 Internal Automatic Drain Reliably discharges collected condesate (excluding KVA and KFS 250 & above). 2 4 Delta P Gauge Large, easy-to-read dual gauge faces allow housings to be mounted in any flow direction. Fitted as standard on filters from 100 scfm and up (except KVA). 5 Modular Connections Space-saving design allows housings to be connected in series without additional piping. 6 Liquid Level Indicator Visually monitor liquid level and verify drain operation. 3 6 Visually monitor liquid level and verify drain operation. KOR/KOX filter elements should be replaced at 10 psid (red area of Delta P gauge) or annually, whichever occurs first. KVF filter elements should be replaced after 1,000 hours of operation or annually, whichever occurs first. Model Cannister 1 Cannister 2 Cannister 3 Kaeser Oil Removal Element Kit Kaeser Oil Removal Element Kit Kaeser Oil Removal Element Kit NMCS % liquid oil OR % liquid oil OX 35 0% liquid removal VF 35 NMCS-10 removal removal.01 micron solid OR 35 OX micron solid.01 micron solid particle VF 35 NMCS-20 particle OR 60 particle OX 60 0 ppm max liquid VF 60 NMCS ppm max liquid OR ppm max liquid OX 100 loading loading loading VF
21 Specifications NMCS7.5 NMCS10 NMCS20 NMCS30 Drive Motor Nominal Power (HP) Motor Style TEFC TEFC TEFC TEFC Compressor rated pressure (psig) rated pressure (CFM) Airend Type (Sigma) Noise Level (db(a)) Standard Elec Configuration (V±10% acceptable) /1/60 dryer 208/3/60 240/3/60 460/3/60 Amp Draw 115v) /3/60 240/3/60 460/3/ /3/60 240/3/60 460/3/ /3/60 240/3/60 460/3/ Compressor Oil Type Capacity (gallons) Kaeser FG gallons Kaeser FG gallons Kaeser FG gallons Kaeser FG gallons Air Receiver Capacity (gallons) Dimensions (inches) Weight (pounds) Ambient Operating Temp ( F / C) 27.5 x 52 x 58h 31 x 50 x 69h 36 x 55 x 74h 85 x 36 x 74h F C F C F C F C 21
22 Date Hours Operator Observations, Comments 22
23 Date Hours Operator Observations, Comments 23
24 Brownie s M A R I N E G R O U P 940 NW 1st Street, Fort Lauderdale, FL PH Fx
Gas Mixing System. Operator s Manual. This manual is also available online
Brownie s M A R I N E G R O U P Tri-Ox MAKER TM Gas Mixing System Operator s Manual This manual is also available online 940 NW First Street, Fort Lauderdale, FL 33311 USA Ph 954-462-5570 Fx 954-462-6115
More informationTechnical Information
Technical Information Installation, Operation, Installation, Operation and Maintenance and Maintenance Manual Manual Balston Model 75700-K728 Nitrogen Generator Figure 1-75700-K728 Overall Dimensions These
More informationOperation Manual. Element HP TM. Open Model Nitrox System
Operation Manual Element HP TM Open Model Nitrox System If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805 815 4044
More informationSERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL
More informationSERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL
www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.
More information3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289
3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for
More informationPortable Oil Lube Air Compressors
Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be
More informationTable of Contents. Operating Instructions. Resource v.2 Conserving Regulator
Operating Instructions Table of Contents Resource v.2 Conserving Regulator Safety Information Device Precautions Introduction Product Features Product Specifications Feature Illustrations Set Up Usage
More informationOperating Manual. Model BAC-30RT30/BAC-30DC
Model BAC-30RT30/BAC-30DC Manual No. BAC012 (Rev 1 October 2002) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100
More informationUser Manual Nuvair LP280 EK76 Nitrox Generator Rev 08.18
User Manual Nuvair LP280 EK76 Nitrox Generator Rev 08.18 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805 815 4044
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Installation, Operation, and Maintenance Balston Model 75-77 Nitrogen Generator Figure 1-75-77 Overall Dimensions These instructions must be thoroughly read and understood before
More informationOperation Manual. Voyager TM. Nitrox System
Operation Manual Voyager TM Nitrox System If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 1-805-815-4044 FAX: 1-805-486-0900
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll
More informationLP300 EK76 Air Cooled Marine Nitrox Generator
User Manual LP300 EK76 Air Cooled Marine Nitrox Generator Rev 08.18 2 LP300 EK76 Air Cooled Marine Nitrox Generator If you have any questions on this equipment please contact Technical Support at: Nuvair
More informationInstallation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator
Installation, Operation, and Maintenance Manual Parker Balston Figure 1 - N2-04 Nitrogen Generator These instructions must be thoroughly read and understood before installing and operating this product.
More informationSERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Installation, Operation, and Maintenance Balston 75-96 and 75-98 Nitrogen Generation System Tower Pressure Gauge 5'-1" 3'-6" 7'-4" 6'-10 1/2" PLAN VIEW Figure 1 - Balston 75-96 and
More informationUser Manual Nitrox Membrane System
User Manual Nitrox Membrane System 215, 230 & 250 Series Rated for 6 CFM, 10 CFM, 16 CFM, 20 CFM, 32 CFM and 50 CFM Low Pressure Supply Option High Pressure Supply Option This Operation Manual contains
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More informationaccidents which arise due to non-observance of these instructions and the safety information herein.
3 GALLON PANCAKE COMPRESSOR Model: 50959 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationOPERATION MANUAL NTF-60 Plus
OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)
More information4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward
GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air
More informationOperation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER
Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor
More informationOperation Manual. MCH 36D Nitrox System
Operation Manual MCH 36D Nitrox System If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805 815 4044 FAX: +1 805 486
More informationInstallation and User Manual
49124589 Revision A August 2015 PacE Flow Controller Installation and User Manual Save These Instructions Table of contents Table of contents..................................................... 2 INSTALLATION............................................................3
More informationOperation Manual. LP 280 Nitrox Generator TM Gardner Denver/Bottarini Version
Operation Manual LP 280 Nitrox Generator TM Gardner Denver/Bottarini Version If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard, CA 93030
More informationOperation Manual. LP 280 Nitrox Generator With Nitrox Manager. Rotair RVG Version
Operation Manual LP 280 Nitrox Generator With Nitrox Manager Rotair RVG Version If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033
More informationPumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out
PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL
More informationSERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL
Product Manual MST Portable Air Filtration System SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the
More informationFILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS
FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.
More informationB-Series. breathing air systems flow capacity: scfm
B-Series breathing air systems flow capacity: 14-486 scfm B 1 B-Series breathing air systems flow capacity: 14-486 scfm B 1 Leading edge technology and more than 100 years of experience nano-purification
More informationSPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.
2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or
More informationUser Manual. Voyager II & Open Voyager II. Nitrox System Rev 03.19
User Manual Voyager II & Open Voyager II Nitrox System Rev 03.19 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805
More information170-CG Feed Unit SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH
SPONGE-JET 170-CG Feed Unit USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com AUGUST 2014, Sponge-Jet 170-CG User Manual - REV A / DOC: M-MKTG-002ENG
More informationSERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL
1 SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2 GENERAL
More information/ /
GN 4- kw/5.5-0 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN: the dual output solution From cargo blanketing in LNG vessels to the inflation of Formula tires, nitrogen is used in
More informationOperation Manual. LP 500D Nitrox Generator. Rotair Version
Operation Manual LP 500D Nitrox Generator Rotair Version If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: +1 805 815 4044
More informationexceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)
exceeds global breathing air quality standards B 1 breathing air systems flow capacity: 6-486 scfm flow capacity: 8-1500 scfm (13-2550 Nm 3 /hr) breathing air systems flow capacity: 6-486 scfm B 1 Leading
More informationOperation Manual. Nitrox System Rev Element LP TM Nitrox System
Operation Manual Element LP TM Nitrox System Rev 02.16 Element LP TM Nitrox System If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93036
More informationJORDAIR/BAUER Service Manual
JORDAIR/BAUER Service Manual Breathing Air Compressor Maintenance Log Doc. ServiceManual Page - 1 SAFETY RELEASE-2016 The following document is prepared to ensure safety of operators and service technicians.
More informationAIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationCS Controlled Dissolved Gas assembly with optional CS Air Aspirator assembly. Installation and Operation information
CS-425-01 Controlled Dissolved Gas assembly with optional CS-603-01 Air Aspirator assembly Installation and Operation information Serial # CS-XXX Date of shipment:, 2005 Shipped to: Purchase order #: xxxxxxx
More informationOperation Manual. RVK>Q325 LP 28.5hp Diesel or Electric Nitrox System
Operation Manual RVK>Q325 LP 28.5hp Diesel or Electric Nitrox System 02062013 www.nuvair.com If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard,
More informationFilter-Regulator-Lubricator
Filter-Regulator-Lubricator 1/2" NPT Inlet/Outlet Ports PD16.19 July, 2016 Machine Parts & Operating Instructions Save This Document and Educate All Personnel WARNING Always follow the safety instructions
More informationLUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS
AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight
More informationINSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor
INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: (507)
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER MODEL F-4 DRAWING NUMBERS AD042C[ ] AD054C[ ] MANUAL NUMBER IOM-046 REVISION Rev. F, 4/23/2018 TABLE OF CONTENTS SAFETY 3 1. PRODUCT
More informationECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)
ECS Protector PGEN-30 (PGEN-30E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Dimensions (cabinet): 24.5 (W) x 52.5 (H) x 8.5 (D) (622mm(W) x 1,334mm(H) x 216mm(D)) Dimensions
More informationStorage Systems and Accessories
Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single
More informationSERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL
SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 5/08 2 GENERAL
More informationOperation Manual. Voyager III TM. Nitrox System Rev 03.15
Operation Manual Voyager III TM Nitrox System Rev 03.15 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 1-805-815-4044
More informationOperating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)
Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100
More information3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.
3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems Work in a World of Comfort 3M TM Versaflo TM AP-600 Series Air Filtration Panels (AFP)
More informationRASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH
SPONGE-JET RASP RX3 Feed UnitTM USER MANUAL Sponge-Jet, Inc. (USA) 14 Patterson Lane +1-603-610-7950 Newington, NH 03801 www.spongejet.com Sponge-Jet RASP RX3 User Manual - REV A / DOC: MKT-014-ENG SPONGE-JET
More informationRev. B. Operating Instructions
780745-00 Rev. B Operating Instructions 780745-00 Rev. B TABLE OF CONTENTS PAGE Warnings, Cautions, and Notes..............................4-7 Definition of Symbols......................................
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Dehydration Assembly Model DA-1 Drawing No.: AD079CO, AD285CR Manual No.: IOM-018 The information in this manual has been carefully checked for accuracy
More information2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL
2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,
More informationPressure Regulators. Operating Instructions. Instrumentation
Pressure Regulators Operating Instructions FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THIS PRODUCT CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from the
More informationBefore using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.
Operating Instructions for the Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet. Introduction The Praxair
More informationHydro Plant Risk Assessment Guide
September 2006 Hydro Plant Risk Assessment Guide Appendix E10: Compressed Air System Condition Assessment E10. 1 GENERAL Compressed air systems are key components at hydroelectric power plants. Compressed
More informationSF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL
SF SERIES CNG COMPRESSOR MODEL HF-4MH 4 Nm3/Hour Displacement OPERATION MANUAL 1 Content 1. General Description...3 2. Main technical parameters...3 3. Structural principle...4 3.1Main structure...4 3.2Compressor
More informationAir Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
More information200 PSI HIGH-FLOW AIR SOURCE KIT
200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
More informationD Series Air and Water Kit Part# 02550
D Series Air and Water Kit Part# 02550 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged.
More informationINTENDED USE TECHNICAL SPECIFICATIONS
1/2IN. HEAVY-DUTY AIR IMPACT WRENCH OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result
More informationBest Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016
Pneumatics Machine & Design Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016 Contents at Atmospheric Air The air at a compressor s intake contains about 78% nitrogen,
More informationSDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual
SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com
More informationAC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight
Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this
More informationPremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION
DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY
More informationDUAL ACTION SANDER MODEL NO: CAT121 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0211
DUAL ACTION SANDER MODEL NO: CAT121 PART NO: 3110877 OPERATION & MAINTENANCE INSTRUCTIONS LS0211 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please
More informationAIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.
2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials
More information1020 Industrial Drive, Orlinda, TN fax
Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2
More informationWorkhorse 8 Oxygen System Model No 5665, 5673, 5679
11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse 8 Oxygen System Model No 5665, 5673, 5679 Part Number 1815 Revision B SeQual Technologies San Diego, CA USA Cautions,
More informationDRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.
U S E R M A N U A L Model: 19MFA1001 Series SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton,
More informationPORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS
PORTABLE 5 GALLON AIR TANK MODEL 472 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND
More informationTESCOM 50-4X Series Safety, Installation & Start-Up Procedures
Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More informationComposite Pistol-Type Air Needle Scaler OWNER S MANUAL
Composite Pistol-Type Air Needle Scaler OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may
More informationAIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL
00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum
More information200 PSI FAST-FILL AIR SOURCE KIT
200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
More informationNitrogen Tyre Inflator Owner s Manual
Nitrogen Tyre Inflator Owner s Manual Model:PN-8890 Please read this manual carefully before attempting assembly or use. 1 Suit for: Motorcycle, Car, Light Truck, Bus Manual Model Nitrogen Tyre Inflation
More informationTypes 749B and R130 Changeover Manifolds
Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies
More informationNitrogen Supply System
ATMOSCOPE Nitrogen Supply System NS500 Users Guide Copyright 2001 EDSYN, INC. ATMOSCOPE Nitrogen Supply Systems TABLE OF CONTENTS Introduction............................. 3 General Information.......................
More informationCO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype
(R744) Service Station Presentation Contents Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype Page 1 (R744) Service Station Goals Usability Full automatic
More informationANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS
Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This
More informationNGP-250/500 Nitrogen Generator Quick Start Guide
NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document
More informationScrew Compressors 11-22kW
INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature
More informationUser Manual. Nuvair Q-325 (Also Operation and Maintenance for Q-370) Diesel and Electric rev
User Manual Q-325 (Also Operation and Maintenance for Q-370) Diesel and Electric rev. 12.18 Q-325 If you have any questions on this equipment please contact Technical Support at: 1600 Beacon Place Oxnard,
More informationJ Air and Water Kit Instructions Part# 02584
J Air and Water Kit Instructions Part# 02584 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you
More informationJacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions
Jacuzzi J-CQ420 Cartridge Filter Installation and Operating Instructions IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and
More informationPC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual
PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be
More informationRG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free
TM Refrigerant Recovery Machine RG6000 1 Operating Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Safety Precautions WARNING
More informationInstallation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series
Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationFreedom8 ShoeBox Compressor Manual
Freedom8 ShoeBox Compressor Manual Warning!! This product is not a toy! Use or misuse can cause severe injury or death! Use only with adult supervision. This unit is only to be used with tanks, hoses and
More informationOur technical information is based on Tip: calls attention to special information.
SUPPLY TANKS (CBP) 2 General information This manual contains technical information regarding Bayer SeedGrowth Equipment. Please read and understand these instructions completely before proceeding to install
More informationInstallation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.
Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More information1020 Industrial Drive, Orlinda, TN fax
Operation Manual Tank Distribution System A-UPT Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.2 Warnings and Cautions... 1 1.2 Theory of Operation...
More information