1 M E A S U R E M E N T U N I T S 1 Gas metering stations
2 2 M E A S U R E M E N T U N I T S M E A S U R E M E N T U N I T S 3 ROTARY GAS METERS RSG «SIGNAL» TURBINE GAS METERS STG RSG Signal-40-GXX RSG Signal-50-GXX RSG Signal-80-GXX RSG Signal-100-GXX STG STG -80-ХХХ STG-100-ХХХ STG-150-ХХХХХ Name RSG 40-G10 RSG 40-G16 RSG 40-G25 RSG 40-G40 Standard size G10 G16 G25 G40 Q max (ft³/h) 16 (565) 25 (883) 40 (1413) 65 (2295) Measurement range Q max / 1:50 1:100 1:160 1:200 Sensitivity threshold (ft³/h) 0,03 (1,1) 0,03 (1,1) 0,05 (1,76) 0,05 (1,76) Pressure loss ΔР, Pа (psi) 27 (0,0039 psi) 67 (0,0097 psi) 111 (0,016 psi) 268 (0,039 psi) Name RSG 50-G16 RSG 50-G25 RSG 50-G40 RSG 50-G65 RSG 80-G100 RSG 80-G160 RSG 100-G250 Standard size G16 G25 G40 G65 G100 G160 G250 DN, mm 50 (2") 50 (2") 50 (2") 50 (2") 80 (3 1/2") 80 (3 1/2") 100 (4") Qmax (ft³/h) 25 (883) 40 (1413) 65 (2295) 100 (3531) 160 (5650) 250 (8829) 400 (14126") Measurement range Q max / 1:50 1:100 1:160 1:200 1:200 1:200 1:160 Sensitivity threshold (ft³/h) 0,05 (1,76) 0,05 (1,76) 0,05 (1,76) 0,05 (1,76) 0,07 (2,47) 0,15 (5,3) 0,2 (7,1) Pressure loss P, Pa (psi) 10 (0,0015 psi) 27 (0,0097 psi) 71 (0,01 psi) 168 (0,024 psi) 140 (0,02 psi) 220 (0,032 psi) 212 (0,031 psi) Name Type DN, мм (in) Q max (ft³/h) Р < 0,3 (43,5 psi) Overpressure P, MPa (psi) 0,3 (43,5 psi) Р < 0,6 (87 psi) 0,6 (87 psi) Р< 1 (145 psi) Р 1 (145 psi) STG G (2") 100 (3531) 5 (176,6) 3 (105,9) 2,5 (88,3) 2 (70,6) STG G (3") 160 (5650) 8 (282,5) 5 (176,6) 4 (141,2) 3 (105,9) STG G (3") 250 (8829) 8 (282,5) 5 (176,6) 4 (141,2) 3 (105,9) STG G (3") 400 (14126) 13 (459) 8 (282,5) 6 (212) 5 (176,6) STG G (4") 250 (8829) 13 (459) 8 (282,5) 6 (212) 5 (176,6) STG G (4") 400 (14126) 13 (459) 8 (282,5) 6 (212) 5 (176,6) STG G (4") 650 (22954) (459) 11 (388,5) 8 (282,5) STG G (6") 650 (22954) 32 (1130) 20 (706,3) 16 (565) 13 (459) STG G (6") 800 (28252) 32 (1130) 20 (706,3) 16 (565) 13 (459) STG G (6") 1000 (35315) 32 (1130) 20 (706,3) 16 (565) 13 (459) STG G (6") 1600 (56503) 50 (1765,7) 32 (1130) 26 (918,2) 20 (706,3) Parameter name Size or parameter Measured environment Natural gas Maximum pressure, MPa (psi) 1,6 (232 psi) Parameter name Parameter size Temperature of measured and ambient environments, С ( F) ( F) Measured environment Natural gas, nitrogen, air Limits of the basic and relative error, %: Maximum pressure, MPa (psi) Temperature of measured and ambient environments, С ( F) 1,6 (232 psi) ( F) variant 1 ±1,7 % - within the range of discharge from ±0,75 % - within the range of discharge from 0,1 Q max Limits of the basic and relative error, %: variant 2 ±2 % - within the range of discharge from ±1 % - within the range of discharge from 0,1 Q max variant 1 variant 2 ±1,7% - within the range of discharge from to 0,05 Q max ±0,75% - within the range of discharge from 0,05 Q max ±2% - within the range of discharge from ±1% - within the range of discharge from 0,1 Q max variant 3 ±0,75 % - within the range of discharge from 0,1 Q max Sensitivity threshold: - for STG , m 3 /h, not more 0,033 Q max variant 3 ± 0,75 % - within the range of discharge from 0,05 Q max до Q max Calibration interval (verification period), years 6 - for other meters, m 3 /h, not more 0,02 Q max Calibration interval (verification period), years 6
3 4 M E A S U R E M E N T U N I T S M E A S U R E M E N T U N I T S 5 INDUSTRIAL GAS METERS Designed for measuring operating volume of natural gas, free petroleum gas, nitrogen, air and other non-aggressive, clean, dry gas. Application commercial and technological gas metering on industrial and utilities, gas control stations, gas control points and boiler. Used as part of: GRU gas control installation GRPSh gas control point PGB point gas block By request: are made together with indicators. Flow capacity table of rotary meters RSG Signal Type RSG G 10 (1:50) RSG G 16 (1:100) RSG G 25 (1:160) RSG G 40 (1:200) DN, mm Р in ov, MPa 0,0012 0, , , , ,1 0, ,5 50 0,5 80 0, ,2 0, , , , ,3 1, , ,4 1,6 80 1, , , ,5 1, , , , ,6 2, , , , ,7 2, , ,8 2, , , , ,9 3, , , , , , , , ,1 3, , ,2 4, , , , ,3 4, , , , ,4 4, , , , ,5 5, , ,6 5, , , , Flow capacity table of rotary meters RSG Signal, ft³/h Type RSG G 10 (1:50) RSG G 16 (1:100) RSG G 25 (1:160) RSG G 40 (1:200) DN, mm 40 (1 1/2``) 40 (1 1/2``) 40 (1 1/2``) 40 (1 1/2``) Р in ov, Psi Flow capacity table of rotary meters RSG Signal Type RSG G 16 (1:50) RSG G 25 (1:100) RSG G 40 (1:160), ft³/h 0, , , , , , , , , RSG G 65 (1:200) RSG G 100 (1:200) RSG G 160 (1:200) RSG G 250 (1:160) DN, mm Р, MPa 0,0012 0,5 25 0,4 40 0,4 65 0, , , , , ,8 80 0, , , ,2 1,5 75 1, , , , , , , , , , ,4 2, , , , , , , , , ,6 3, , , , , , , , , , , ,8 4, , , , , , , , , , , , , , , , , , , , ,2 6, , , , , , , , , , , , ,4 7, , , , , , , , ,6 8, , , , , , , * Meters can be produced with non-standard expansion 1:20, 1:30, 1:50, 1:80, 1:100, 1:130, 1:160 (but no more specified standard).
4 6 M E A S U R E M E N T U N I T S M E A S U R E M E N T U N I T S 7 Flow capacity table of rotary meters RSG Signal, ft³/h Type RSG G 16 1:50 RSG G 25 1:100 RSG G 40 1:160 RSG G 65 1:200 RSG G 100 1:200 RSG G 160 1:200 RSG G 250 1:160 DN, mm 50 (2``) 50 (2``) 50 (2``) 50 (2``) 80 (3``) 80 (3``) 100 (4``) Р in ov, Psi, ft³/h 0, , , , , , , , , , , , , , , , , , , , , , , , , , Flow capacity table of turbine meters STG Name STG STG STG STG STG STG Measurement range 1:10 1:20 1:20 1:30 1:30 1:20 DN, mm P, MPa 0, , , , , , , , , , , , , , , , Name STG STG STG STG STG STG Measurement range 1:30 1:30 1:20 1:25 1:30 1:30 DN, mm P, MPa 0, , , , , , , , , , , , , , , ,
5 8 M E A S U R E M E N T U N I T S M E A S U R E M E N T U N I T S 9 Flow capacity table of turbine meters STG, ft³/h Name STG STG STG STG STG STG Measurement range 1:10 1:20 1:20 1:30 1:30 1:20 DN, mm (inch) 50 (2``) 50 (2``) 80 (3``) 80 (3``) 80 (3``) 100 (4``) Р in ov, Psi, ft³/h 0, , , , , , , , , GAS VOLUME CORRECTOR FLOWGAS The block of volume correction gas FLOWGAS is designed for reduction of working volume of the gas passing through the counter of gas, to standard conditions (plus of 20 C and Pa). Application area commercial and technology metering of gas on gas distribution stations and gasdistributing points of the industrial enterprises and facilities of utility. Advantages: high metrological stability; measured pressure range 1:10; work at pressure up to 10,0 MPa; pressure losses measurement at the meter; environment temperature measurement; simultaneous operation of two RS-232 and RS-485 interfaces; optical port and 6-button keypad. Description: The operation principle of the block is based on measurement of the current values of pressure, temperature, gas volume under operating conditions and calculations according to information received taking into account component composition of gas volume and the gas flow rate to reduced to standard conditions.. Specification Proofreader of PTZ «Flowgas» in unassembled form Parameter name Flowgas-10А Flowgas-16А Flowgas-30А Flowgas-80А Flowgas-100А Name STG STG STG STG STG STG Measurement range 1:30 1:30 1:20 1:25 1:30 1:30 DN, mm (inch) 100 (4``) 100 (4``) 150 (6``) 150 (6``) 150 (6``) 150 (6``) Р in ov, Psi, ft³/h 0, , , , , , , , , Measurement ranges of absolute pressure, MPa (psi) 0,08-1,0 (11,6-145 psi) 1,6-16 ( psi) 0,3-30 (43,5-435 psi) Relative error of pressure channel, % ±0,25 Absolute error of temperature, С ±0,5 Relative error reduction measured gas volume to standard conditions, % Operating temperatures range, С ( F) ±0,4 from -40 to +50 ( F) Environment Temperature, С ( F) from -20 to +50 (-9, F) Interface Archives RS 232, RS 485, optical port 0,8-80 ( psi) 1,0-10 ( psi) hourly data archive 600 days; daily data archive 60 months; monthly data archive 2000 months; alarms data archive 4000 records; changes archive 2000 records Calibration interval, years 6 Explosion protection 1ExibIIAT4Х Dust and moisture protection IP 66 Inlet volume pulse Dimensions (length, width, height), mm Weight, kg (lb) Body material LF inlet (2 Hz Max) 220x197x220 2,0 (4,4 lb) Aluminum
6 10 M E A S U R E M E N T U N I T S M E A S U R E M E N T U N I T S 11 Specification GAS VOLUME CORRECTOR TZ FLOWGAs-T Correction unit gas volume FLOWGAS-T is designed to bring the working volume of gas passing through the gas meter to standard conditions (plus 20 C and Pa) with a constant pressure. Used at the utility with a gas pressure in the pipeline no more than 0,05 MPa. Parameter name Flowgas-T Relative error of the measurable pressure canal, % ±0,25 Absolute error of temperature measurement, С ±0,5 Relative error reduction measured gas volume to standard conditions, % ±0,4 Operating temperatures range, С ( F) from -40 to +50 ( F) Temperature measured environment, С ( F) from -20 to +50 ( F) Interface RS 232, RS 485, optoport Archives The hourly average 600 days; the average daily 60 months; the average monthly 2000 month; emergency situations 4000 records; archive of changes 2000 records Calibration interval (verification period), years 6 Explosion protection 1ExibIIAT4Х Dust / moisture protection IP 66 Inlet volume pulse LF inlet (2Гц Max) Dimensions (length, width, height), mm 120x102,5х60 Weight, kg 2,0 Body material Aluminum GAS MEASUREMENT COMPLEXES KI-STG Complexes for measuring the gas amount KI-STG intended for measurement of volume of natural gas and automatically bring measured gas volume to standard temperature in dependence on pressure, temperature and gas compressibility coefficient. Application commercial and technological gas metering at the industrial and utilities enterprises, gas distribution stations, gas distribution points and boiler rooms. Specification Complex type KI-STG-TS-(1) KI-STG-TS-(2) KI-STG-TS-(3) (special order)* KI-STG-RS-(1) Limits of relative error in determining the volume of gas reduced to standard conditions ±2% on flow rate from ±1% on flow rate from 0,1 Q max ±2,3% on flow rate from ±1,3% on flow rate from 0,1 Q max ±1% on flow rate from 0,1 Q max ±2% on flow rate from to 0,05 Q max ±1% on flow rate from 0,05 Q max GAS VOLUME CORRECTOR PTZ BK KI-STG-RS-(2) KI-STG-RS-(3) (special order)* ±2,3% on flow rate from to 0,05 Q max ±1,3% on flow rate from 0,05 Q max ±1% on flow rate from 0,05 Q max Specification The corrector is designed for measurement, calculation and indication of volume and the gas flow rate which has passed through the counter of gas, and their reduction to standard conditions. Application commercial and technology metering of gas on gas distribution stations and gas-distributing points of the industrial enterprises and facilities of utility services. Parameter name BK-10A-1-M BK-16A-1-M Measurement ranges of absolute pressure, kgf/cm² 0,9-10 (130, psi) 1,6-16 ( psi) Reduced error of pressure channel, % ±0,25 Absolute error of temperature, С ±0,5 Relative error reduction measured gas volume to standard conditions, % ±0,4 Operating temperatures range, С ( F) from -40 to +60 ( F) Temperature measured environment, С ( F) from -20 to +60 ( F) Interface RS 232 / RS 485 Archives hourly data archive 45 days; daily data archive 3 months; alarms data archive 300 records Calibration interval (verification period), years 4 Explosion protection 1ExibIIAT4Х Dust / moisture protection IP 54 Inlet volume pulse LF inlet (2Hz Max) Dimensions (length, width, height), mm 220x197x220 Weight, kg (lb) 2,5 (5,5 lb) Body material Aluminum Complex is based on the diaphragm gas meter «KI-STG-MS» ±3,5% on flow rate from to 0,1 Q nom ±2% on flow rate from 0,1 Q nom Relative error of channel pressure measurement, % ±0,4 Relative error of temperature measurement, % ±0,15 Relative error reduction measured gas volume to standard conditions, % Measurement range of absolute pressure, bar Calibration interval (verification period), years 4-6 * Minimum flow rate complexes variant 3 (special order) are 0,1 Q max and 0,05 Q max on the basis of STG and RSG meters respectively. KI-STG-MS specification ±0,5 0,9-10 1,6-16 Name DN, mm (in) (ft³/h) Q max, (ft³/h) KI-STG-DM /G10 32 (1 1/4") 0,01 (0,35) 16 (565) KI-STG-DM /G16 40 (1 1/2") 0,016 (0,56) 25 (883) KI-STG-DM /G25 50 (2") 0,025 (0,88) 40 (1413) KI-STG-DM /G40 80 (3") 0,04 (1,4) 65 (2295)
7 12 M E A S U R E M E N T U N I T S O T H E R E Q U I P M E N T S O F C O M P A N Y G R O U P «S I G N A L» KI-STG-TS specification Type DN, mm Q max, (ft³/h) Р < 0,3 (43,5 psi) Overpressure P ov, MPa (psi) 0,3 (43,5 psi) Р < 0,6 (87 psi) 0,6 (87 psi) Р < 1 (145 psi) Р 1 (145 psi) G (2") 100 (3531) 5 (176,6) 3 (105,9) 2,5 (88,3) 2 (70,6) G (3") 160 (5650) 8 (282,5) 5 (176,6) 4 (141,2) 3 (105,9) G (3") 250 (8829) 8 (282,5) 5 (176,6) 4 (141,2) 3 (105,9) G (3") 400 (14126) 13 (459) 8 (282,5) 6 (212) 5 (176,6) G (4") 250 (8829) 13 (459) 8 (282,5) 6 (212) 5 (176,6) G (4") 400 (14126) 13 (459) 8 (282,5) 6 (212) 5 (176,6) G (4") 650 (22954) 20 (706,3) 13 (459) 11 (388,5) 8 (282,5) G (6") 650 (22954) 32 (1130) 20 (706,3) 16 (565) 13 (459) G (6") 800 (28252) 32 (1130) 20 (706,3) 16 (565) 13 (459) G (6") 1000 (35315) 32 (1130) 20 (706,3) 16 (565) 13 (459) G (6") 1600 (56503) 50 (1765,7) 32 (1130) 26 (918,2) 20 (706,3) «Manometer» LLC Manometers EZOT «SIGNAL» Transportable boiler plants TKU KI-STG-RS specification Standard size for DN 40, mm G10 G16 G25 G40 Q max (ft³/h) 16 (565) 25 (883) 40 (1413) 65 (2295) Measurement range Q max / 1:50 1:100 1:160 1:200 Threshold of sensitivity (ft³/h) 0,03 (1,1) 0,03 (1,1) 0,05 (1,76) 0,05 (1,76) Pressure Loss P, Pa 27 (0,0039 psi) 67 (0,0097 psi) 111 (0,016 psi) 268 (0,039 psi) Standard size G16 G25 G40 G65 G100 G160 G250 DN, mm (in) 50 (2") 50 (2") 50 (2") 50 (2") 80 (3") 80 (3") 100 (4") Qmax (ft³/h) 25 (883) 40 (1413) 65 (2295) 100 (3531) ) 250 (8829) 400 (14126") Measurement range Q max / 1:50 1:100 1:160 1:200 1:200 1:200 1:160 Threshold of sensitivity, m³/h (ft³/h) Pressure Loss P, Pa 0,05 (1,76) 0,05 (1,76) 0,05 (1,76) 0,05 (1,76) 0,07 (2,47) 0,15 (5,3) 0,2 (7,1) 10 (0,0015 psi) 27 (0,0097 psi) 71 0,01 psi) 168 (0,024 psi) 140 (0,02 psi) 220 (0,032 psi) 212 (0,031 psi) The automated gas distribution stations AGRS Ultramag specification Type G10 G16 DN, mm (in) 40 (1 1/2") 40 (1 1/2") Q max, (ft³/h) Qt, (ft³/h) variant 1 (ft³/h) variant2 (ft³/h) Dimension Weight, kg (lb) 16 (565) 0,8 (28,3) 0,08 (2,83) 0,16 (5,6) 320х130х (33 pounds) 25 (883) 1,25 (44,1) 0,16 (5,6) 0,25 (8,8) 320х130х (33 pounds) G25 50 (2") 40 (1413) 2 (70,6) 0,25 (8,8) 0,4 (14,1) 320х130х (33 pounds) G40 50 (2") 65 (2295) 3,25 (114,8) 0,4 (14,1) 0,65 (22,9) 320х130х (33 pounds) G65 80 (3") 100 (3531) 5 (176,6) 0,65 (22,9) 1 (35,3) 320х185х (42 pounds) G (3") 160 (5650) 8 (282,5) 1 (35,3) 1,6 (56,5) 380х255х (50,7 pounds) G (4") 250 (8829) 12,5 (441,4) 1,6 (56,5) 2,5 (88,3) 380х255х (50,7 pounds) G (4") 400 (14126) 20 (706,3) 2,5 (88,3) 4 (141,2) 380х255х (50,7 pounds) Heating boilers KOV Pressure losses on Ultramag meters at the maximum flow rate does not exceed: 320 Pa variant 2; 700 Pas variant 1. Local resistances do not change the error meters «Ultramag» in the direct pipeline not less 5DN at the inlet, and not less 3DN at the outlet.
8 JSC EPO Signal Saratov region, Engels-19 Ph./fax: 8 (8453) , Help service (call free): Hot line concerning quality and operation: 8 (845) s: marketing@eposignal.ru orgo@eposignal.ru
FAS-W. Features. Applications. Automatic condensation hygrometer
FAS-W HUMIDITY ANALYZER Automatic condensation hygrometer the «FAS-W» Moisture Analyzer automatic condensation hygrometer can measure both the volume fraction of moisture and the dew point temperature
More informationProduct information. Ultrasonic Gas Meter. Custody Transfer Measurement in Natural Gas Distribution
Product information FLOWSIC500 Ultrasonic Gas Meter Custody Transfer Measurement in Natural Gas Distribution FLOWSIC500 Ultrasonic Gas Meter Custody transfer measurement in natural gas distribution Product
More informationTRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.
TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering
More informationOnline data sheet FLOWSIC500 GAS FLOW METERS
Online data sheet FLOWSI500 FLOWSI500 A F H I J K L M N O P Q R S T US Ordering information Type FLOWSI500 Part no. On request The exact device specifications and performance data of the product may deviate
More informationFPG8601 Force Balanced Piston Gauge
FPG8601 Force Balanced Piston Gauge Reference Level Calibration System for very low pressure Pressure range: 0 to 15 kpa gauge, absolute and absolute differential Standard resolution: 0.010 Pa, high resolution
More informationVersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.
VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and
More informationUltrasonic Flowmeter USZ 08
Ultrasonic Flowmeter USZ 08 PRODUCT INFORMATION Reliable Measurement of Gas Fields of application, method of operation and construction 2 Fields of application The ultrasonic flowmeter is an advanced measuring
More informationRR 16 Commercial & Industrial Regulator
Gas RR 16 Commercial & Industrial Regulator Applications The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations
More informationpren CEN standard-draft pr EN 12261
CEN standard-draft pr EN 12261 CEN standard-draft according to engl version from 06/1998 Meter Classification Pressure ratings, gas meter sizes, dimensions, temperature ranges Metrological performance
More informationM-06 Nitrogen Generator (Nitrogen Making Machine)
Guideline No.M-06 (201510) M-06 Nitrogen Generator (Nitrogen Making Machine) Issued date: 20 th October, 2015 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains
More informationProduct Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12
Product Information Three in One: Gas Meter Tariff Device Volume Corrector Ultrasonic Gas Meter ECOSONIC X12 ECOSONIC X12 Values you can count on The Application Fields The ultrasonic gas meters of the
More informationElectro Pneumatic System for Measuring Level in Ballast, Service Cargo Tanks and Vessel Draught
Electro Pneumatic System for Measuring Level in Ballast, Service Cargo Tanks and Vessel Draught BMS4 Operating manual Man 081a CONTENTS 1 Introduction... 3 1.1 Purpose and structure of the operating manual...
More informationElectronic gas volume corrector model DGVC-04
Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationCERTIFICATE on measurement instruments type approval
FEDERAL AGENCY FOR TECHNICAL REGULATION AND METROLOGY CERTIFICATE on measurement instruments type approval Valid to July 9th, 07 CH.C.9.004.А No. 4765 MEASUREMENT INSTRUMENTS TYPE NAME Mass flowmeter Promass
More informationG4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER
Gas Meters content G4S G4A1KY RESIDENTIAL CONVERSION KIT LOW PRESSURE CONVERSION KIT MEDIUM PRESSURE CONVERSION KIT HIGH PRESSURE CONVERSION KIT ULTRASONIC GAS METER G4S G4S Residential Diaphragm Type
More informationDrum-Type Gas Meters Series TG (Wet-Test)
Drum-Type Gas Meters Series TG (Wet-Test) Precision Volumetric Gas Meters for Scientific Laboratories User Benefits Highest accuracy: ±0.5% across full flow rate range Calibration traceable to German National
More informationRMG Meßtechnik GmbH. Publication No E
Electronic Turbine Meter TERZ 94 RMG Meßtechnik GmbH Publication No. 3.174-E P.O.ox 280 35502 utzbach (Germany) Tel.: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Internet: http://www.rmg.de
More informationMeasuring Instrument Type Approval CERTIFICATE
FEDERAL AGENCY ON TECHNICAL REGULATING AND METROLOGY Measuring Instrument Type Approval CERTIFICATE CH.C.29.004.А No. 50322 Valid until: 02.04.2018. MEASURING INSTRUMENT TYPE NAME t-mass Thermal Flowmeters
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationcombustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen
More informationPerformance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH
Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH 1 D-K-15143-01-00 Services around the measurement technology in Germanys most accurate DAkkS laboratory*. Whether
More informationMASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS
MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationInstruction and Maintenance Manual
Instruction and Maintenance Manual GRYF OXY ZM 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 www.gryf.eu ver.: 11.2.2015 OEM module
More informationMetering Code Gas TSO, measurement by connected party Effective from to the present
Please note that although Gasunie Transport Services B.V. translated the Dutch network codes with utmost care, Gasunie Transport Services B.V. would like to point out that only the decisions of the Dutch
More informationATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in
More informationINTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL OIML R 32 RECOMMENDATION Edition 1989 (E) Rotary piston gas meters and turbine gas meters Compteurs de volume de gaz à pistons rotatifs et compteurs de volume de gaz à turbine OIML R 32 Edition
More informationP06 & P012 Pitot-Static Probes
P06 & P012 Pitot-Static Probes Operating Instructions: Measure in straight duct sections that are at least 1.5 diameters upstream and 8.5 diameters downstream of any duct disturbance such as elbows and
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationHigh-speed pressure sensor Model CPT6140
Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications
More informationP8 to P60 Pitot-Static Probes
P8 to P60 Pitot-Static Probes Operating Instructions: Install optional PX NPT fitting if required. See separate documentation for details. Measure in straight duct sections that are at least 1.5 diameters
More informationcombustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring
More informationBAROMETER PRESSURE STANDARD PRESSURE CONTROLLER
BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement
More informationRDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005
RDK-408D2 Cold Head Technical Manual SHI-APD Cryogenics Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision A: September 2005 (Reference SHI Manual: December 18, 2003 266404A CD32ZZ-160A)
More informationPTG100 Precision Test Gauge
PTG100 Precision Test Gauge User Manual PD1007 Rev B 03/28/2014 Palmer Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131 Fax: 828-658-0728 Email:
More informationRR 16 Commercial & Industrial Regulator
RR 16 Commercial & Industrial Regulator The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations where accurate
More informationPHOENIX L300i Best-in-class Helium Leak Detectors
180.85.02 Best-in-class Helium Leak Detectors The perfect Helium leak detector matching your demands The helium leak detector opens up new dimensions of productivity and reliability for your applications.
More informationTEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125
TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 Model: VC-40-VYC Table of contents 1. - Installing the test bench 1.1.1- Connecting the compressed air / nitrogen source 1.1.2- Maximum test pressure according
More informationInstruction and Maintenance Manual
Instruction and Maintenance Manual GRYF OXY Z 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 Czech Republic www.gryf.eu Technical
More informationS300 Series. Valve Link. Features. Fisher Controls
S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a
More informationSize : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic
More informationSSR. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationSafety Shut-off Valve SSV
Safety Shut-off Valve SSV 8200-8300 < Accurate operation < Compact design < Easy maintenance Applications The safety shut-off valve is designed for use in gas distribution, and pressure regulation systems.
More informationGas Pressure Regulator HON 200
Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationHigh-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements
More informationBest Practices for Installation of Gaseous Sample Pumps
Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure
More informationR18 General purpose pressure regulators
> > Port size: / & (ISO G, PTF) > > Can be installed at any point in the compressed air system without regard to accessibility pilot regulator can be installed in the most convenient location > > Accurate
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationType 299 Pressure Reducing Regulators
Type 299 Pressure Reducing Regulators Fisher, Fisher-Rosemount, and Managing The Process Better are marks owned by Fisher Controls International, Inc. or Fisher-Rosemount Systems, Inc. All other marks
More informationXMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:
XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery
More informationSINGLE VALVE WITH LOW-FLOW BYPASS
CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationTechnical Information Conducal CLY421
TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified
More informationMounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)
Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Type 42-10 RS Check Valve (backflow protection) Mounting and Operating Instructions EB 3009 EN Edition December 2015 Definition
More information780S Ultra High Purity Series
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board
More informationHUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationMod. M M M063..
CATALOGUE > Release 8.6 > Pressure gauges Pressure gauges Mod. M04.. - M05.. - M06.. Precision classes CL1,6 and CL2,5» Radial connection» Rear connection» Panel mounting To select the most suitable pressure
More informationSSL. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationCompiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.
1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact
More informationGas Pressure Regulator HON 270 MK2
Gas Pressure Regulator HON 270 MK2 PRODUCT INFORMATION Serving the Gas Industry Worldwide Introduction, Application, Features & Technical Data Introduction The HON 270 MK2 regulator is a direct acting,
More informationWATER PRESSURE REDUCER (SBD)
WATER PRESSURE REDUCER (SBD) December 2016 PRODUCTS Product Code Connection Size Range of Products Max. Input Pressure Pressure Setting Range 340308 1/4" SBD 340315 1/2" SBD 340415 1/2" with sleeve coupling
More informationTOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson
TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson OGA SEMINAR DECEMBER 3, 2012 OGA Seminar 2012 2 Regulators Meters Valves Flanges
More informationTechnical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description
Smart-Trak Model 100 High Performance Digital Gas Mass Flow Meters and Controllers Features Measure & control gas mass flow rates up to 1000 slpm True digital performance provides high accuracy and great
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationSANP ACTING RELAYS YT-520/525/530 SERIES
SANP ACTING RELAYS YT-520/525/530 SERIES PRODUCT MANUAL VERSION 1.02 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 2. Product Description.. 4 2.1 General..
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More information1 PIPESYS Application
PIPESYS Application 1-1 1 PIPESYS Application 1.1 Gas Condensate Gathering System In this PIPESYS Application, the performance of a small gascondensate gathering system is modelled. Figure 1.1 shows the
More informationAir Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
More informationProcess Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.
Process Solutions Electronic Turbine Meter TERZ 9 PROVEN TEHNOOGY. SUPERIOR PERFORMNE. Electronic Turbine Meter TERZ 9 Method of Operation The TERZ 9 electronic turbine meter is a flow meter which directly
More informationPressure Regulator 133 / 233
Benefits Accurate regulation Exchangeable component technique Easy maintenance Suitable for HTB requirements DVGW-approval (DIN 3380/81, VP 200). Description The 133/233 regulator is a direct-acting, spring
More informationParametrable / Programmable Pressure Transmitter
Parametrable / Programmable Pressure Transmitter PTM/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available
More informationSmart Water Application Technologies (SWAT)
Smart Water Application Technologies (SWAT) Turf and Landscape Irrigation Equipment PRESSURE REGULATING SPRAY HEAD SPRINKLERS Equipment Functionality Test Testing Protocol Version 3.0 (May 2012) Developed
More informationType 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator
January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity
More informationSP/ST/SA Models Pulse-input and Analog-input Control
SP/ST/SA Pulse-input and -input Control Smart and Intuitive Operation Simple key functions and user interface for ease of operation. Range can be set between 1 and 3 strokes per minute in 1-stroke units.
More informationAurora. Moisture Measurement for Industrial Gases. GE Measurement & Control
GE Measurement & Control Aurora Moisture Measurement for Industrial Gases GE s Aurora analyzer uses tunable diode laser absorption spectroscopy (TDLAS) to rapidly and accurately measure moisture in industrial
More informationModels 461-S, 461-8S and S Regulators. R-1330 Rev. 7
Models 461-S, 461-8S and 461-12S Regulators R-1330 Rev. 7 461-S, 461-8S and 461-12S Regulators The Sensus Models 461-S, 461-8S and 461-12S are balanced valve, spring type regulators designed for distribution
More informationGA24 Technical Datasheet
GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)
More informationVisualize Nitrogen Gas Consumption
Air Flow Monitor EWA2 SERIES Conforming to EMC Directive (all models) & Pressure Equipment Directive (AEWA2150/2200 only) Visualize Nitrogen Gas Consumption Small pipe size as Well as Air Consumption!
More informationThe Shand & Jurs Model Vapor Guard Tank Blanketing Valve
Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More information7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications
GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the
More informationHUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationCHAPTER 3 : AIR COMPRESSOR
CHAPTER 3 : AIR COMPRESSOR Robotic & Automation Department FACULTY OF MANUFACTURING ENGINEERING, UTeM Learning Objectives Identify types of compressors available Calculate air capacity rating of compressor
More informationThe number of revolutions is proportional to the passed volume. The rotation is transferred to a mechanical index, which indicates this volume.
RVG and RVG-ST Rotary Gas Meters Applications Media: Natural gas, town gas, propane, inert gases Industry: Gas supply, stove manufacturers, chemical industry. Tasks: Measurement, control and automatic
More informationNoth American 7347 High Pressure Gas Regulators
Combustion Noth American 7347 High Pressure Gas s Bulletin 7347 7347 s reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across the regulator (see
More information7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel
KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with
More informationOxygen Measurement Systems High Reliability and Wide Application Coverage
Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding
More informationElectronic Turbine Meter TERZ 94
Electronic Turbine Meter TERZ 9 PRODUT INFORMTION Reliable Measurements of Gas EETRONI TURINE METER TERZ 9 Methode of operation, construction 2 Methode of operation The TERZ 9 electronic turbine meter
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationMass Flow Meter (MFM) for gases
Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version
More informationGAS DELIVERY PRESSURE AND MEASUREMENT
GAS DELIVERY PRESSURE AND MEASUREMENT I. PURPOSE: To establish a uniform basis on which to provide gas measurement and pressure regulation facilities on customers premises. II. DELIVERY PRESSURES AND PROVISIONS:
More informationPRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES
PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the
More information