Parts identification:
|
|
- Gwendoline Holmes
- 5 years ago
- Views:
Transcription
1 ARTERY PUNCTURE AND INTRAMUSCULAR TRAINING ARM Parts identification: FAST-derm replacement skin (removable) Intramuscular injection pad (removable for cleaning) Training arm (includes one FAST-derm replacement skin) Arm tubing and luer locks Arm tubing clamps FAST-fluid management system: Collection bottle Upper tubing Upper tubing clamp Lower tubing FAST-fluid tower Pulse bulb Luer locks Syringe Lower tubing clamp 2
2 Assembly instructions: 1. Assemble the FAST-fluid tower by sliding the two base pieces together. 2. Secure by threading the small black rubber plug through the holes forming a circle. 3. Close clamps on upper tubing, lower tubing and pulse bulb tubing. 4. Prepare fluid for collection bottle with distilled water or saline. Note: To represent blood, tint fluid with red food coloring or use a mixture of simulated blood with distilled water or saline. 5. Remove cap on the collection bottle. Fill collection bottle to 800ML with fluid making sure to not fill past the upper tubing. Tighten cap on the collection bottle. 6. Set the filled collection bottle onto the FAST-fluid tower. Note: The height of the tower was designed to provide realistic flashback. Elevating the bottle to this level will increase the fluid pressure and assist in providing the flashback. 3
3 ARTERY PUNCTURE AND INTRAMUSCULAR TRAINING ARM Set-up instructions: 1. Connect the upper and lower tubing luer lock connectors on the collection bottle to the connectors on the training arm tubing. 2. Prime the arm s arteries by opening the clamps on the upper and lower tubing. Note: To prevent air lock during priming, lay arm and tubes on a level surface. Purging the air from arteries takes a few seconds. 3. Close the clamps on the upper and lower tubing. 4. Open clamp on the pulse bulb tubing. 4
4 Use instructions: System is now ready for use. A series of pulse bulb contractions will create a pulse. A very realistic pulse will be felt at both the radial and brachial sites when squeezed. 1. To perform radial arterial puncture: a. Have a partner press the pulse bulb to create a pulse. b. Palpate the radial artery in the arm. c. Follow the proper steps for performing arterial puncture.** 2. To perform brachial arterial puncture: a. Have a partner press the pulse bulb to create a pulse. b. Palpate the brachial artery in the arm. c. Follow the proper steps for performing arterial puncture.** 3. To perform an intramuscular injection: a. Locate the injection site on the upper part of the training arm. b. Follow the proper steps for performing an intramuscular injection** Note: Saline or water are recommended for the IM injection site **See the curriculum for steps on performing arterial puncture and intramuscular injections 5
5 ARTERY PUNCTURE AND INTRAMUSCULAR TRAINING ARM Cleaning and storage instructions: For best results, perform the following instructions at a sink. 1. Close all tubing clamps. 2. Keeping tubes above the arm, disconnect them from the collection bottle. 3. Place tubes into a sink or reservoir. 4. Hold arm above tubes, open both clamps and allow tubes to empty. Note: This works best if the arm is held high enough for the tubes to hang straight down and thus avoid kinks. Note: If the fluid used was tinted; use the syringe to flush with clean water. A. Fill the syringe with clean water. B. Stand the arm upright. C. Connect the syringe to the tubing and inject until full. D. Disconnect syringe and repeat steps three and four to drain the fluid. E. Repeat steps A to D as needed. 5. Empty collection bottle, remove cap and rinse with water. 6. Remove pulse bulb and rinse out with water. 7. Wipe the exterior of the arm with warm water. Pat dry with a clean cloth. Allow all parts to dry overnight. 8. Store trainer in a dry warm place out of direct sunlight. Care after intramuscular injection: 1. Remove the pad from the upper arm. Remove the interior sponge. 2. Rinse well using warm water. 3. Squeeze or wring out the additional water from the sponge. 4. Allow to dry overnight completely before inserting sponge back into injection pad. 6
6 FAST-derm replacement skin instructions: 1. Remove the FAST-derm replacement skin by gently pulling on the Velcro along the length of the slit. 2. Gently peel skin off. 3. Open additional replacement and slide the skin over the hand stump (fingers are pre-populated in the replacement skin) and gently over the length of the arm. 4. Close skin by securing the Velcro the length of the arm, starting at the hand and working your way down to the elbow. Additional care tips: 1. Needles: 22-gauge or smaller needles are recommended as larger needles reduce the life of the product. Puncturing the skin repeatedly for practice will lead to deterioration over time. Use sharp needles as dull needles may cause unnecessary damage to the skin and arteries. 2. Puncture Site: To extend the life of the arm, distribute injections along the accepted injection sites. 3. Use only distilled water or saline. Use of other solutions may block the tubing for the arteries. 4. Do not use iodine, betadine or other antiseptics to clean the site as they may stain the skin permanently. You may use alcohol pads. 5. Follow cleaning instructions above after each use. 7
PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL
PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL DO NOT REMOVE FILM FROM TUBING! THIS PRODUCT CONTAINS DRY NATURAL RUBBER! Products by NASCO About the Simulator The Life/form Pediatric
More informationInfant IV Leg LF03636U Instruction Manual
Infant IV Leg LF03636U Instruction Manual Products by Nasco About the Simulator The Life/form Infant IV Leg Simulator is an exciting training aid for practicing and demonstrating intravenous puncture
More informationNita Newborn Model 1800 User Manual
Nita Newborn Model 1800 User Manual 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 fax 503.651.5052 email info@vatainc.com www.vatainc.com Meet Nita Newborn TM Nita Newborn is a unique
More informationNewborn Nursing Skills and ALS Simulator LF01400U Instruction Manual
Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual Products by Nasco About the Simulator Meeting your neonatal resuscitation program course curriculum, the Life/form Newborn Nursing Skills
More informationBleeding Trauma Module Set. Directions for Use
Bleeding Trauma Module Set Directions for Use 38 15 50 2 Laerdal TABLE OF CONTENTS Items Included 4 Skills Taught 5 Attaching Modules to Manikin 6 Set-up Procedures for Connecting Blood Bags to Modules
More informationCHILD CRiSis INJECTABLE TRAINING ARM LF03612U INSTRUCTION MANUAL
CHILD CRiSis INJECTABLE TRAINING ARM LF03612U INSTRUCTION MANUAL Warning this product contains dry, natural rubber. Products by NASCO Synthetic Blood Posterior Anterior Pinch Clamp Venous System 12" Anterior
More informationAdvanced IV Hand LF01139U & LF01146U Instruction Manual
Advanced IV Hand LF01139U & LF01146U Instruction Manual WARNING: This product contains dry natural rubber. Do not remove film from tubing! Products by Nasco List of Components 3 cc syringe with needle
More informationCVC Insertion Simulator
M93UB CVC Insertion Simulator Don t mark on the model and other components with pen or leave printed materials contacted on their surface. Ink marks on the models will be irremovable. Instruction Manual
More informationStandard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610
User Guide Abdominal Aortic Aneurysm (AAA) Repair Trainer Part No: 6060 Standard Part No: 065-088 Issue, June 005 04 Limbs & Things For more Vascular training products visit limbsandthings.com Limbs &
More informationChild CRiSis Injectable Training Arm LF03612U Instruction Manual
Child CRiSis Injectable Training Arm LF03612U Instruction Manual Warning: This product contains dry, natural rubber. Products by Nasco Synthetic Blood Posterior Anterior Pinch Clamp Venous System 12" Anterior
More informationAbdominal Aortic Aneurysm (AAA) Repair Trainer User Guide
Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide Designed and manufactured by Limbs & Things Limited, Sussex Street, St. Philips, Bristol, BS 0RA, UK. Telephone: +44 (0)7 3 0500 Fax: +44 (0)7
More informationAdult Sternal Intraosseous Infusion Simulator LF04200U Instruction Manual
Adult Sternal Intraosseous Infusion Simulator LF04200U Instruction Manual Products by Nasco Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 About the Simulator The Life/form Adult Sternal Intraosseous Infusion
More informationINFANT INJECTABLE TRAINING LEG LF03636U INSTRUCTION MANUAL
INFANT INJECTABLE TRAINING LEG LF03636U INSTRUCTION MANUAL Products by NASCO About the Simulator... The Life/form Infant Injectable Training Leg Simulator is an exciting training aid for practicing and
More informationlimbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.
User Guide Advanced Venepuncture Arm Product No: 00290 (Light) Product No: 00298 (Brown) For more skills training products visit limbsandthings.com Limbs & Things Ltd. Sussex Street, St Philips Bristol,
More informationTraining Device Instructions
Training Device Instructions May 2011 www.pyng.com 2011 Pyng Medical Corp. Pyng Medical has developed two types of devices to aid in the training curriculum of the FAST1 : The FAST1 Training Device and
More informationSTANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )
Page 1 of 27 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Advanced Intravenous Training Arm in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy
More informationINTERMEDIATE INFANT MANIKIN LF03700U INSTRUCTION MANUAL
INTERMEDIATE INFANT MANIKIN LF03700U INSTRUCTION MANUAL Products by Nasco Table of Contents page Introduction 2 Airway Management Trainer 3 IV Arm 4 IV Leg 9 Intraosseous Infusion Leg 14 Chest Skin with
More informationAT Kelly Torso. Directions for Use
AT Kelly Torso Directions for Use 260-00001 2 Table of Contents Recommends 4 Items Included 5 Skills Taught 5 Preparing the Manikin for Use 6 Head 6 Lungs 6 Abdominal Thrust 6 Instructions for Use 6 Airway
More informationUltrasound Compatible Lumbar Puncture/ Epidural Simulator
M43E Ultrasound Compatible Lumbar Puncture/ Epidural Simulator Instruction Manual Contents Please read General information Preparation Before training Training After training P.1 P.2-6 P.7 P.8-10 It includes
More informationArticulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual
Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual Products by Nasco C. O. A. D. B. E. M. I. J. G. K. H. F. N. L. About the Simulator Designed to attach easily to any Life/form
More informationTable of Contents. Introduction 2. Airway Management Trainer 3. IV Arm 4. IV Leg 9. Intraosseous Infusion Leg 14
INFANT MANIKIN LF03709U INSTRUCTION MANUAL CAUTION: THIS PRODUCT CONTAINS DRY NATURAL RUBBER! Life/form Products by Nasco Table of Contents page Introduction 2 Airway Management Trainer 3 IV Arm 4 IV Leg
More informationArterial and Venous Patient Training Arm S
Arterial and Venous Patient Training Arm S402.100 Gaumard Simulators for Health Care Education Arterial and Venous Patient Training Arm is an interactive educational system developed to assist a certified
More informationAR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual
AR251/AR251-B Venepuncture and Infusion Arm Instruction Manual Thank you for purchasing this AR251 Venepuncture and Infusion Arm. Cast from life, it shows a well developed male left arm in fine detail.
More informationSkin and Vein Replacement Kit LF01122U (Light Skin) LF01123U (Dark Skin) LF01124U (Vein) Instruction Manual
Skin and Vein Replacement Kit LF01122U (Light Skin) LF01123U (Dark Skin) LF01124U (Vein) Instruction Manual CAUTION: PRODUCT CONTAINS DRY NATURAL RUBBER! DO NOT REMOVE FILM FROM TUBING! Products by Nasco
More informationArterial Puncture Wrist. Instruction Manual
Arterial Puncture Wrist Instruction Manual Production supervision Dr. Hiroshi Koyama National Hospital Organization Kyoto Medical Center ENGLISH Index Features Components Before training While training
More informationAT Kelly Torso. Directions for Use
AT Kelly Torso Directions for Use Table of Contents Recommends 4 Items Included 5 Skills Taught 5 Preparing the Manikin for Use 6 Head 6 Lungs 6 Abdominal Thrust 6 Instructions for Use 6 Airway Management
More informationPort - Body in a Box User s Manual
Port - Body in a Box - 5010 User s Manual 308 South Sequoia Parkway Canby, Oregon 97013 USA ph. 503.651.5050 fax 503.651.5052 email info@vatainc.com Thank you for purchasing VATA s Port - Body in a Box
More informationTo assist you in preparing STAT Baby for student activities we offer the following set up suggestions:
No 350 Stat Baby Instructions for STAT Baby, item 350 To assist you in preparing STAT Baby for student activities we offer the following set up suggestions: After connecting fluid reservoir bags to the
More informationNG Tube and Trach Skills Trainer LF01174U Instruction Manual
NG Tube and Trach Skills Trainer LF01174U Instruction Manual Products by Nasco The Nasco Life/form NG Tube and Trach Skills Trainer offers students realistic experience in the insertion and management
More informationPeripheral Venous Catheter Placement Simulator
Attention Do not let ink from pens, newspapers, this manual or other sources come in contact with the manikin, as they cannot be cleaned the manikin skin. MW9 Peripheral Venous Catheter Placement Simulator
More informationUltrasound Guided Thoracentesis / Pericardiocentesis Simulator Full set
Do not mark on the model and other components with pen nor leave printed materials contacted on surface. Ink marks on the models cannot be removed. MW7 Ultrasound Guided Thoracentesis / Pericardiocentesis
More informationArterial Puncture Wrist
M99 Arterial Puncture Wrist Production supervision Dr. Hiroshi Koyama, Medical Director, General Internal Medicine National Hospital Organization Kyoto Medical Center Instruction manual Caution Do not
More informationUltrasound Guided Thoracentesis Simulator Strap-on Type
Caution Do not mark on the model and other components with pen nor leave printed materials contacted on surface. Ink marks on the models cannot be removed. MW4A Ultrasound Guided Thoracentesis Simulator
More informationUltrasound Guided Thoracentesis Simulator Strap-on Type
Do not mark on the model and other components with pen nor leave printed materials contacted on surface. Ink marks on the models cannot be removed. MW4A Ultrasound Guided Simulator Strap-on Type Instruction
More informationStandard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442
Setup Guide Bag & Stand Advanced Standard Light. Part No: 00440 Brown. Part No: 0044 Black. Part No: 0044 Part No: 065-0 Issue, May 0 0 Limbs & Things For more skills training products visit limbsandthings.com
More informationStandard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332
Setup Guide Standard Standard Light. Part No: 000 Brown. Part No: 00 Black. Part No: 00 Part No: 065-964 Issue, June 0 0 Limbs & Things For more skills training products visit limbsandthings.com Limbs
More informationInstructions and User Guide. Ultrasound Musculoskeletal Training Model BPMSK-1000 Series. April 26, 2016 Rev 1.0
Instructions and User Guide Ultrasound Musculoskeletal Training Model BPMSK-1000 Series April 26, 2016 Rev 1.0 1 Overview 1 Giving you the confidence only experience can offer Congratulations on the purchase
More informationInformation for patients and nurses. Rocket Ambulatory Chest Drain
Information for patients and nurses Rocket Ambulatory Chest Drain Contact Information Hospital Sticker: District Nurse based at: Contact Number: Contact Name: GP: Contact Number: Hospital Ward: Contact
More informationPERFORMANCE OF A FINGERSTICK
PERFORMANCE OF A FINGERSTICK Follow the procedure as outlined above for greeting and identifying the patient. As always, properly fill out appropriate requisition forms, indicating the test(s) ordered.
More informationPatients Guide for Self Administering Intravenous Antibiotics General points
Patients Guide for Self Administering Intravenous Antibiotics General points An intravenous line is an open route for infection therefore you need to prevent this by washing your hands before any procedure
More informationUltrasound Guided Thoracentesis Simulator
Do not mark on the model and other components with pen nor leave printed materials contacted on surface. Ink marks on the models cannot be removed. MW4 Ultrasound Guided Simulator Instruction Manual Contents
More informationSkin and Vein Replacement Kit LF01122 (White Skin) LF01123 (Black Skin) LF01124 (Vein)
Skin and Vein Replacement Kit LF01122 (White Skin) LF01123 (Black Skin) LF01124 (Vein) CAUTION: PRODUCT CONTAINS DRY NATURAL RUBBER! DO NOT REMOVE FILM FROM TUBING! Products by Nasco Connector Block Supplement
More informationChapter 40. Fluid, Electrolyte, and Acid Base Balance. Procedures Checklist INTRAVENOUS THERAPY. Procedure 40.1: Starting an Intravenous Infusion
Procedures Checklist INTRAVENOUS THERAPY Chapter 40 Fluid, Electrolyte, and Acid Base Balance Procedure 40.1: Starting an Intravenous Infusion Performed Preparation Yes No Mastered Comments 1. Assess:
More informationInfant ECG/Umbilical Cannulation Skin LF03710U Instruction Manual
Infant ECG/Umbilical Cannulation Skin LF03710U Instruction Manual Products by Nasco About the Simulator The Life/form Infant ECG/Umbilical Cannulation Skin is an exciting training aid for practicing and
More informationAIRWAY MANAGEMENT TRAINER LF03601U INSTRUCTION MANUAL
AIRWAY MANAGEMENT TRAINER LF03601U INSTRUCTION MANUAL Products by NASCO Set Up: The Airway Management Trainer is ready to use upon delivery. Simply remove it from the carton and unwrap the packaging material.
More informationBasic Flows in a Microfluidic Device
Basic Flows in a Microfluidic Device Vishal Tandon 1 Introduction Microfluidic devices are used to transport, mix, and separate analytes in small sample volumes for chemical or biological analysis. Understanding
More informationChester Chest Model 2400 User s Manual
Chester Chest Model 2400 User s Manual 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 fax 503.651.5052 email info@vatainc.com Thank You For Your Purchase! Thank you for your purchase
More informationChester Chest Model 2400 User s Manual
Chester Chest TM Refurbishing Service The purchase of training models is a significant financial investment. Realizing this, VATA is proud to offer a refurbishing service, to bring your model to new condition.
More informationAlfred ECMO Circuit Priming and Storage Guide
Alfred ECMO Circuit Priming and Storage Guide 1 March 2012 Check List Page 2. Assembly, Priming and Storage Page 3. Prepare ECMO trolley and Circuit immediately before use Page 6. Connection to Patient
More informationInstructions and User Guide. Ultrasound Central Line Training Models BPH660 Series, BPH665-C Series, BPHNB670 Series, BPHNB675-C Series
Instructions and User Guide Ultrasound Central Line Training Models BPH660 Series, BPH665-C Series, BPHNB670 Series, BPHNB675-C Series November 23, 2011 Rev 1.0 Contents 3 Chapter One: Overview 3 Giving
More informationAirway Larry Airway Management Trainer Head LF03667U Instruction Manual
Airway Larry Airway Management Trainer Head LF03667U Instruction Manual CAUTION: PRODUCT CONTAINS DRY NATURAL RUBBER! Products by Nasco A. B. C. About the Simulator The Life/form Airway Larry Airway Management
More informationEndo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax
OPERATION MANUAL Zutron Medical, LLC 17501 W 98 th St #40-27 Lenexa, KS 66219 Phone 877-343-5873 Fax 913-967-5944 ZUT-Lab-004-30004 REV. 03312017 Table of Contents 2 Introduction 1. Intended Use 2. Labels,
More informationS109 NEWBORN PEDI USER GUIDE
S109 NEWBORN PEDI USER GUIDE Newborn PEDI is an interactive educational system developed to assist a certiied instructor. It is not a substitute for and not intended for clinical decision making. User
More informationDeluxe Child CRiSis Manikin LF03617U Instruction Manual
Deluxe Child CRiSis Manikin LF03617U Instruction Manual Products by Nasco Table of Contents Page Introduction 2 Airway Management Trainer 3 IV Arm 4 Blood Pressure Arm 8 Defibrillation Chest Skin with
More informationCENTRAL IOWA HEALTHCARE Marshalltown, Iowa
CENTRAL IOWA HEALTHCARE Marshalltown, Iowa INTENSIVE CARE UNIT POLICY & PROCEDURE Policy Number: R-28/4.22 Subject: Purpose: Policy: Arterial Monitoring Use of intra-arterial pressure monitoring allows
More informationC-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8
A Forehead support Forehead pads C Mask Frame Mask Elbow Cushion clip Mask Cushion C-7 C-1 Vent cover Ports cap Cuff ActiveCell C-6 Short air tubing Upper Velcro straps Swivel Lower Velcro straps Headgear
More informationChild CRiSis Manikin Simulator LF03616U Instruction Manual
Child CRiSis Manikin Simulator LF03616U Instruction Manual WARNING: Products may contain dry natural rubber. Products by Nasco Table of Contents.............................Page Introduction...2 Airway
More informationINJECTABLE TRAINING ARM
INJECTABLE TRAINING ARM INSTRUCTIONS FOR INSTALLING LF03215U REPLACEMENT SKIN ON IV ARM LF03214U DO NOT REMOVE FILM FROM TUBING! THIS PRODUCT CONTAINS DRY NATURAL RUBBER! Products by NASCO Remove Old Skin
More informationSPEMS SKILLS PROFICIENCY CRITERIA Paramedic
SPEMS SKILLS PROFICIENCY CRITERIA Paramedic The following skills are required at the Paramedic Level: 1. King Airway 2. IV 3. Endotracheal Intubation 4. Adult EZ IO 5. Pedi EZ IO 6. Pleural Decompression
More informationUPPER ARM INTRA-MUSCULAR INJECTION SIMULATION KIT USER MANUAL
UPPER ARM INTRA-MUSCULAR INJECTION SIMULATION KIT USER MANUAL 1 FOREWORD Thank you very much for buying from us the Upper Arm Intra-muscular Injection Simulation Kit. This simulation kit will help you
More information6 & 8 Bubble Panel Installation Manual
6 & 8 Bubble Panel Installation Manual IMPORTANT RETAIN FOR FUTURE REFERENCE READ CAREFULLY You must use Distilled Water only. Use of any water other than distilled voids the warranty. Please check the
More informationRECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)
Website for more information: http://www.recombinate.com/ INSTRUCTIONS FOR USE RECOMBINATE [Antihemophilic Factor (Recombinant)] (For intravenous use only) Do not attempt to do an infusion to yourself
More informationINSTRUCTION MANUAL Elisa Baby-PICC
The simulator is ideal for techniques and skills in vascular access and intravenous therapy. The newborn is made of semi-flexible and non-toxic material. It measures approximately 52cm in height and weighs
More informationTJF-Q180V Cleaning and Disinfection Checklist
TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-Q180V has been performed
More informationTechnical Bulletin AL-134
Technical Bulletin AL-134 Handling Air-Sensitive Reagents The Aldrich Sure/Seal system Anhydrous solvents and air-sensitive reagents from Aldrich are packaged in our exclusive Sure/Seal bottles which provide
More informationTEV-TROPIN [somatropin (rdna origin) for injection] 5 mg & 10 mg
TEV-TROPIN [somatropin (rdna origin) for injection] 5 mg & 10 mg TEV-TROPIN (somatropin for injection) Information for the Patient or Parent Read all instructions before proceeding. Do not mix (reconstitute)
More informationDELUXE CHILD CRiSis MANIKIN WITH ECG SIMULATOR LF03617U INSTRUCTION MANUAL
DELUXE CHILD CRiSis MANIKIN WITH ECG SIMULATOR LF03617U INSTRUCTION MANUAL Products by NASCO Table of Contents page Introduction 2 Airway Management Trainer 3 IV Arm 4 Blood Pressure Arm 8 Defibrillation
More informationBOYLE S / CHARLES LAW APPARATUS - 1m long
BOYLE S / CHARLES LAW APPARATUS - 1m long Cat: MF0340-101 (combination Boyle s and Charles without mercury) DESCRIPTION: The IEC Boyle's & Charles Law apparatus is a high quality instrument designed to
More informationComplete CRiSis Update Package LF03959U Instruction Manual
Complete CRiSis is Update Package LF03959U Instruction Manual Products by Nasco Limited Warranty Nasco warrants to the purchasers of CRiSis products that they will be free from defects in material and
More informationTJF-Q180V Cleaning and Disinfection Checklist
TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-Q180V has been performed
More informationRadnoti Liver Perfusion System
Radnoti Liver Perfusion System 130003 Offset Offset Gain Gain Radnoti 2006 Description Qty Part # A Base only, for 4-bar stand 1 159950-B4 B Stabilizer Bar only, for 4-Bar stand 2 159950-C4 C Rod 24 Long
More informationInfant Auscultation Trainer and SmartScope LF01201U Instruction Manual
Infant Auscultation Trainer and SmartScope LF01201U Instruction Manual Caution: Product Contains Dry Natural Rubber Products by Nasco The Life/form Infant Auscultation Trainer allows you to simulate resuscitation,
More informationTridak Model 1050 User Guide
Tridak Model 1050 User Guide Syringe Filling System Instructions for Safe Use Setup and Operation Maintenance Ordering Spare Parts and Accessories 2 Tridak Model 1050 Syringe Filling System User Guide
More informationUSER GUIDE, VOL.2.0 MYOGRAPH SYSTEM - 112PP/114P
USER GUIDE, VOL.2.0 MYOGRAPH SYSTEM - 112PP/114P CONTENTS CHAPTER 1 4 1.1 Pressure Myograph 114P overview 4 1.2 Pressure Myograph 112PP overview 5 CHAPTER 2 - SET-UP THE PRESSURE MYOGRAPH 6 2.1 Adjustment
More informationUsing the Akta Prime plus October 22, 2012
Some starting precautions: 1. Vacuum filter all buffers. Removes any large particles/debris that may clog your column De-gases the buffers 2. Clarify lysates first by centrifugation and then filtration
More informationARTERIAL MONITORING. Final Approval: VP Operations, Chief Nursing Officer Distribution: ICU, PACU POLICY:
Policy Number: R-28 / Care of Patient 4.22 Section: Intensive Care Date Written: June 1988 Date(s) Revised: 8/98, 6/01, 11/03 Date(s) Reviewed: 4/92, 12/93, 7/95, 6/04 Reviewed/Approved by: Dept.Cmt. Date
More informationSyringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT
ATTENTION SYRINGE REPLACEMENT Please read through the document completely before starting any repairs. Refer to the proper section in the service manual for complete removal and replacement procedures.
More informationPIMA MEDICAL INSTITUTE RADIOGRAPHY PROGRAM ARRT GENERAL PATIENT CARE COMPETENCIES CPR
CPR STUDENT CLINICAL SITE Perform CPR Demonstrate the proper techniques utilized for CPR Provided preceptor with a copy of current CPR certification card *Not * If a competency is initialed as Not, it
More informationAneroid Sphygmomanometer. Use, Care, & Maintenance
Aneroid Sphygmomanometer Use, Care, & Maintenance 1 Device Description and Intended Use An aneroid sphygmomanometer is used by professional healthcare providers and individuals trained in the auscultatory
More informationSolvent System Walkthrough
v2.0 1 Solvent System Walkthrough The Contour Glass solvent system is designed to give you air-free anhydrous solvent with minimal effort. However, the system is only as good as its users so please read
More informationSanta Fe Cycles Assembly Guide Introduction
Santa Fe Cycles Assembly Guide Introduction Congratulations on your purchase of your new Santa Fe bicycle. You have purchased a bicycle that has many features and qualities. Please take a few minutes and
More informationMODEL 1329 Tank Gauge
SERVICE INSTRUCTIONS FOR PETRO-METER 1329 GAUGE SERVICE INSTRUCTIONS MODEL 1329 Tank Gauge www.petro-meter.com Petro-Meter 1329 series Service Instructions HOW TO DETERMINE IF A PETRO-METER IS IN GOOD
More informationNOTES PATIENT DETAILS
NOTES PATIENT DETAILS Patient Name: Patient MRN: Department: Date of Insertion: Type of Central Line: Size of Central Line: Booklet given and explained by: Signed: CONTACT NUMBERS Hospital Telephone No:
More informationleaders in enteral delivery
feeding kit user guide leaders in enteral delivery 10 20 30 ml 1 medicina balloon gastrostomy Reorder No. 82-281 FIVE GRAM LUBRICATING JELLY Water Soluble STERILE unless opened or damaged 1 2 3 4 5 6 7
More informationA designated area will have been assigned for all blood specimens to be taken. All blood should then be taken in that area only.
Venepuncture No: 008D 1. Introduction Blood sampling is a necessary requirement to assess the biochemical and haematological profile of subjects who enter clinical research studies. Risks to the subject
More informationGeneral Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead
General Warnings A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead to patient injury, illness, or death. WARNING: Do not
More informationAirway Larry AIRWAY MANAGEMENT TRAINER INSTRUCTION MANUAL
Airway Larry AIRWAY MANAGEMENT TRAINER LF03699U INSTRUCTION MANUAL Products by NASCO About the Simulator The Life/form Airway Management, Airway Larry, is the most realistic simulator available for the
More informationOPERATOR S MANUAL HOTLINE 3 Blood and Fluid Warmer
l OPERATOR S MANUAL - HOTLINE 3 Blood and Fluid Warmer < HL-390-38 6 s l HOTLINE 3 Blood and Fluid Warmer < HL-390-38 OPERATOR S MANUAL PN 4534013EN Rev. 002 s G e n e r a l I n f o r m a t i o n HOTLINE
More informationVarithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.
Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product. The Instructions for Use are for the entire Varithena TM system. There are
More informationClinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care
Clinician Guide Baxter Elastomeric Devices Promoting patient-centric care Portfolio Overview Portfolio Overview Baxter Elastomeric Devices are non-electronic medication devices designed to provide ambulatory
More informationAseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC
Aseptic Techniques Techniques for Sterile Compounding Pharmacy Technician Training Systems Passassured, LLC Aseptic Techniques, Tech for Sterile Compounding PassAssured's Pharmacy Technician Training Program
More informationATD LB PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off
More informationVarithena Delivery System Instructions for Use
Varithena Delivery System Instructions for Use Please read all prescribing information before using the product. The Instructions for Use are for the entire Varithena system. There are 2 packaging configurations:
More informationINSTALLATION INSTRUCTIONS
EDGEMERE CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More informationS PREMIE HAL USER GUIDE. User Guide Gaumard Scientiic Company, All Rights Reserved
S108.100 PREMIE HAL USER GUIDE User Guide 18.1.2 Gaumard Scientiic Company, 2018 Newborn PEDI is an interactive educational system developed to assist a certiied instructor. It is not a substitute for
More informationInstallation Instructions
Installation Instructions COLONY SOFT 7.0 Centerset Lavatory Faucet 7.0 with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a features found
More informationInstallation of Your SprayMaster System
Installation of Your SprayMaster System 1. At the installation site, remove all equipment from the corrugated box and the polyethylene drum and replace the drum lid. Check the picture to identify each
More informationCHILD INJECTABLE TRAINING ARM INSTRUCTIONS FOR INSTALLING LF03629U REPLACEMENT SKIN ON IV ARM LF03612U
CHILD INJECTABLE TRAINING ARM INSTRUCTIONS FOR INSTALLING LF03629U REPLACEMENT SKIN ON IV ARM LF03612U This kit includes specially-treated tubing, upper and lower arm skins, liquid lubricant, and lubricating
More informationUnisense In Situ UniAmp Connector System
Unisense In Situ UniAmp Connector System Overview The Unisense In Situ UniAmp Connector system is designed for easy replacement of sensors. Unisense In Situ UniAmp Connector system is a dedicated system
More informationPRESSURE MYOGRAPH - 114P PULSATILE PRESSURE MYOGRAPH - 112PP
USER GUIDE PRESSURE MYOGRAPH - 114P PULSATILE PRESSURE MYOGRAPH - 112PP User Guide Version 1.1 CONTENTS Chapter 1 - Pressure Myograph Overview 3 1.1 Pressure Myograph 114P Overview. 3 1.2 Pulsation Pressure
More information