Pixel Thermographics Ltd. Compressed Air Leak Detection Survey SAMPLE REPORT. Pixel Thermographics Ltd
|
|
- Shon Owen
- 5 years ago
- Views:
Transcription
1 Compressed Air Leak Detection Survey By Sunrise House Hulley Road Macclesfield Cheshire SK10 2LP Tel: +44 (0) Web:
2 Survey Information This sample report has been issued to provide an example as to the layout, content and quality of our compressed air leak survey service. A UE Systems Ultraprobe 3000 Ultrasonic Leak Detector was used to capture the Ultrasonic data which is recorded within this report. Where equipment was surveyed and no leaks or faults were found then no data is recorded i.e. individual reports are generated by exception. Some areas of particular interest may be included which the surveyor feels may be of particular interest to the client. Descriptions of equipment and locations have been noted as those in common usage within the client s premises. Follow up work including remedial work and investigations into causation etc. or any other factors outside the control of are not the responsibility of and are not covered by this contract. Where have been unable to inspect equipment or plant which is covered, unexposed or inaccessible, we are therefore unable to report that any such system components are free from defect. Areas un-inspected are highlighted in the scope pages of this report. To assist the Engineering Management to maintain plant efficiency, it is recommended that the survey is repeated on a twelve monthly basis. This report is an indication of the condition of the equipment inspected at the time and date of survey only. Signed: <<<<<<<<<<<<<< Date: Surveyor Disclaimer: Please note that the report contained herein represents the observed conditions at the time of inspection. accepts no liability for faults that have occurred during or after the completion of the inspection. The recommendations given in this report are intended as a guide only. By issuing this report neither Pixel Thermographics Ltd nor any of its employees make any warranty, expressed or implied, concerning the contents of this report. cannot accept responsibility for inappropriate actions taken as a result of this report. 2 (27)
3 Scope of Survey The scope of this survey was to carry out a compressed air leak survey across the site on all areas where compressed air systems are located. This encompassed internal and external areas throughout the site which were made accessible by the client. Report Data A summary of all ultrasonic data is contained in the report pages that follow. The pages in this report have been designed as single page entries, each of which carries its own information so that individual pages can be given to the relevant professions in order that they may carry out any remedial repairs that may be necessary. Compressed Air Leak Surveys All compressed air systems are subject to mechanical deterioration at connections, flexible pipes, regulators, valves etc due to looseness, over-tightening, corrosion and contamination. If these conditions remain uncorrected further deterioration will occur resulting in equipment failure and leakage of expensive compressed air. Compressed air is not free and it costs hard earned revenue to generate with the following costs being part of the generation process: Compressor Cost (Purchase) Electricity costs Generation Efficiency Cost Air Drier running costs Maintenance costs Equipment deterioration As such compressed air is one of the most costly utilities in a facility today. A simple program of leak inspection and repair can go a long way towards reducing excessive energy costs. Air Supply Data Used For the purpose of compiling this report we have taken the air supply pressure to be 7.0 BarG and the annual compressor usage to be 24 hours a day for a seven day week with a 52 week working year which gives us an annual compressor running time of 8736 hours. 3 (27)
4 Leak Levels and Ratings This survey has been designed to assess the performance of all compressed air generation, distribution and equipment on site and to highlight any areas which require attention. To assist in the prioritising of repairs we apply a severity rating (level) based on the results of the leak detection survey. The severity levels are ranked as follows: Level Leak Size in CFM: Minimum Maximum Leak Description: Small Medium Large Very Large Leak Costs We calculate individual leak costs based on the following information provided by the client and from compressor data: Detail Value Cost of Electricity (p/kwh) 9.4p Compressed Air Generating Efficiency (kw/100cfm) Generating Pressure (BarG) 7 Hours of Operation per Year (Hours) (27)
5 Leak Identification Number: Cost Benefit Analysis 10oz Area Size of Leak in CFM: Cost of Leak per Annum : Total Overall value of Air Loss Leak Identification Number: Cost Benefit Analysis SIG Area Size of Leak in CFM: Cost of Leak per Annum : Total Overall value of Air Loss The above tables provide a summary of the individual leak costs and subsequent total annual cost of wasted compressed air leak generation. Larger leaks or inappropriate uses of air should be targeted first to rapidly reduce costs associated with wasted compressed air generation. 5 (27)
6 Summary of Air Leaks Detected Ultrasonic leak detection equipment was utilised to locate and measure air leakage from compressed air systems. Below is a summary of all leaks found: Leak No. Area: 10 oz Leak Details: Level: 1 10oz - Bottle filler filters No access from ceiling oz - Labeller reject Jubilee clip on filter housing knocker oz - Prasmatic middle Threaded union onto filter filter housing oz - Beginning of labeller Threaded union on hand gun hand blower oz - Above bottle lid Threaded joint on pressure gauge machine oz - Feed to bottle filler Push fit oz - Lid dryer Permanently on even when line has paused oz - Glue tub sucker Threaded union on solenoid oz - Barcode label dryer Permanently on even when line has paused 3 Leak No. Area: SIG Leak Details: Level: 1 SIG - Main product tank Top of filter housing 5 2 SIG - Lid blower near Blower permanently on with no product inspection scales 5 3 SIG - Caged area near Push fit onto solenoid broken bottle bin 1 4 SIG - Pump side of oven Threaded joint onto valve control half way along 2 5 SIG - Conveyer side of oven Hole in pipe near weighing machine 3 6 SIG - Conveyor side of oven Threaded joint on solenoid near front 1 7 SIG - Conveyor side of oven Filter housing near front 3 8 SIG - Feed to labeller Push fit to T 2 9 SIG - Reject pusher before Push fit into filter housing pallet machine 3 10 SIG - Dud detector filter Push fit into filter housing 1 11 SIG - Detector after labeller Jubilee clip on main feed 1 12 SIG - Glue tub sucker Solenoid housing 2 6 (27)
7 10oz Bottle filler filters 1 No access from ceiling 1 Annual Cost of Leak: (27)
8 10oz - Labeller reject 2 Jubilee clip on filter housing knocker 2 Annual Cost of Leak: (27)
9 10oz - Prasmatic middle 3 Threaded union onto filter filter housing 2 Annual Cost of Leak: (27)
10 10oz - Beginning of 4 Threaded union on hand gun labeller hand blower 1 Annual Cost of Leak: (27)
11 10oz - Above bottle lid 5 Threaded joint on pressure gauge machine 4 Annual Cost of Leak: (27)
12 6 10oz - Feed to bottle filler Push fit 4 Annual Cost of Leak: (27)
13 7 10oz - Lid dryer Permanently on even when line has paused 4 Annual Cost of Leak: (27)
14 8 10oz - Glue tub sucker Threaded union on solenoid 2 Annual Cost of Leak: (27)
15 10oz - Barcode label 9 Permanently on even when line has paused dryer 3 Annual Cost of Leak: (27)
16 1 SIG - Main product tank Top of filter housing 5 Annual Cost of Leak: (27)
17 SIG - Lid blower near 2 Blower permanently on with no product inspection scales 5 Annual Cost of Leak: (27)
18 SIG - Caged area near 3 Push fit onto solenoid broken bottle bin 1 Annual Cost of Leak: (27)
19 SIG - Pump side of oven 4 Threaded joint onto valve control half way along 2 Annual Cost of Leak: (27)
20 SIG - Conveyer side of 5 oven near weighing Hole in pipe machine 3 Annual Cost of Leak: (27)
21 SIG - Conveyor side of 6 Threaded joint on solenoid oven near front 1 Annual Cost of Leak: (27)
22 SIG - Conveyor side of 7 Filter housing oven near front 3 Annual Cost of Leak: (27)
23 8 SIG - Feed to labeller Push fit to T 2 Annual Cost of Leak: (27)
24 SIG - Reject pusher before 9 Push fit into filter housing pallet machine 3 Annual Cost of Leak: (27)
25 10 SIG - Dud detector filter Push fit into filter housing 1 Annual Cost of Leak: (27)
26 SIG - Detector after 11 Jubilee clip on main feed labeller 1 Annual Cost of Leak: (27)
27 12 SIG - Glue tub sucker Solenoid housing 2 Annual Cost of Leak: (27)
Best Practices for Ultrasonic Compressed Air Leak Detection
Best Practices for Ultrasonic Compressed Air Leak Detection Adrian Messer, CMRP, Manager of US Operations UE Systems, Inc. Ph: 864-224-4517 Web: www.uesystems.com Email: adrianm@uesystems.com Abstract
More informationHydro Plant Risk Assessment Guide
September 2006 Hydro Plant Risk Assessment Guide Appendix E10: Compressed Air System Condition Assessment E10. 1 GENERAL Compressed air systems are key components at hydroelectric power plants. Compressed
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationFluid Sealing Association
Fluid Sealing Association STANDARD FSA-PSJ-701-06 PIPING SYSTEMS NON-METALLIC EXPANSION JOINT HYDROTESTING AND VACUUM TESTING 994 Old Eagle School Road, Suite 1019 Wayne, Pennsylvania 19087-1866 Phone:
More informationSeptember 2018 Pressure Test
September 2018 Pressure Test The requirements for a pressure test are found in NFPA 54, Chapter 8, Sections 8.1-8.1.53 of the 2012 edition. A pressure test shall not be confused with a leak check. The
More informationBUZZI UNICEM USA PENSACOLA TERMINAL MILTON, FLORIDA
BUZZI UNICEM USA PENSACOLA TERMINAL MILTON, FLORIDA May, 2017 Infrared Inspection Report Buzzi Unicem Terminal 6266 Da Lisa Road Milton, Florida, 32583 Company Contact Andy Rogers Project: 04110517 2605
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationTECHNICAL DATA OBSOLETE
April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,
More informationAccu-Tab Systems 2000 P Series by Axiall Corporation
Accu-Tab Systems 2000 P Series by Axiall Corporation Installation and Operating Instructions Models 2075 P 2150 P For NSF/ANSI-Standard 61 NSF STANDARD 61 applications use NSF/ANSI Standard 60 listed Axiall
More informationGETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )
GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised 11-24-10) 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com
More informationWATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity
WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed
More informationIndustrial Compressed Air. Ultrasonic Leak Detection Survey Guide
Industrial Compressed Air Guide Introduction For many manufacturers compressed air represents the second or third highest utility cost in their facility. Without an effective maintenance program in place
More informationCocoa Patio Pond with Lit Spillway
Cocoa Patio Pond with Lit Spillway REMINDER CALL 1-888-755-5641 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM # GQSPPB/GQSPPW Questions, problems, missing parts? Before returning to your retailer, call
More information5 Gallon Pressure Pot with HVLP Spray Gun and Hose
California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,
More informationPressure Relief Valve Instruction Manual
CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:
More informationMaintenance handbook
Maintenance handbook ontents HPU IDENTIFIATION SHEET... 4 1. MAINTENANE... 5 1.1 Filling level... 5 1.2 Fluid top-up... 5 1.3 Fluid replacing... 5 1.4 Fluid temperature control... 6 1.5 Functional control...
More informationModel ASSEMBLY and OPERATING INSTRUCTIONS
QUICK CHANGE AIR BRUSH KIT Model 93506 ASSEMBLY and OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,
More informationTECHNICAL BULLETIN DESIGNING A FUNCTIONAL COMPRESSED AIR SYSTEM
TECHNICAL BULLETIN DESIGNING A FUNCTIONAL COMPRESSED AIR SYSTEM The purpose of a compressed air system is to provide an efficient means of transmitting an adequate volume and quality of air to pneumatic
More informationATD LB PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off
More informationPRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855
More informationModel No Product Name Handpiece Only Complete System
Ney QC 700 E 30,000 RPM IECE 30,000 R N HANDPIE IVEN HA R DRIV AIR D Owner & Operator's Manual Model No Product Name 7201326 Handpiece Only 7201325 Complete System Description Page Safety... 2 Setup...
More informationG7S Hand Pump Owner s Manual
G7S Hand Pump Owner s Manual Copyright Air Venturi 2018 Version 4-18 Specifications 24.80 inches long closed 43.31 inches long extended 4500 psi/310 bar max pressure Features Integral manometer (pressure
More informationCode AWC20HP Air Compressor
Code 951816 AWC20HP Air Compressor Index of Contents Index of Contents 02 Declaration of Conformity 02 What s Included 03 Safety Precautions 03 Specifications (AWC20HP Air Compressor) 04 Assembly Instructions
More informationR E D I C O N T R O L S
R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature
More informationSYSCO ST JOHN'S MOUNT PEARL, NEWFOUNDLAND
SYSCO ST JOHN'S MOUNT PEARL, NEWFOUNDLAND October, 2016 Infrared Inspection Report Sysco St. John s 10 Old Placentia Road Mount Pearl, NF A1N 4P5 Company Contact: David Shaw Project: C261016 2605 CHARTER
More informationCOMPRESSED AIR DISTRIBUTION SYSTEMS
Series COMPRESSED AIR DISTRIBUTION SYSTEMS 18 DESIGNING AN EFFICIENT COMPRESSED AIR DISTRIBUTION The main source of inefficiencies and problems affecting compressed air distribution systems is often the
More informationPAVESTONE COMPANY CST PAVERS PEDRICKTOWN, NEW JERSEY
PAVESTONE COMPANY CST PAVERS PEDRICKTOWN, NEW JERSEY October, 2015 Infrared Inspection Report Pavestone Company Company Contact Joe Dougan Project: 06051015 2605 CHARTER OAK DRIVE, LITTLE ROCK, AR 72227
More informationAccu-Tab Systems 1000 Series by Axiall Corporation
Accu-Tab Systems 1000 Series by Axiall Corporation Installation and Operating Instructions Model 1050 DANGER: DO NOT MIX CHEMICALS! The Accu-Tab chlorinator is designed for use with Axiall approved tablets
More informationSIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information
SIX R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) POSITION CYLINDERS Service Information The six and seven position cylinders are medium duty pneumatic positioning devices that operate
More informationCOSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE
COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 www.cosasco.com
More informationTHE DELIVERY OF GAS SUPPLY
GAS ASSIST INJECTION MOLDING THE DELIVERY OF GAS SUPPLY April 2010 www.bauerptg.com THE DELIVERY OF GAS SUPPLY Gas assist requires a source of high-pressure nitrogen gas that can be controlled and delivered
More informationSYSCO ALLARD VILLE DE QUEBEC, QUEBEC, CANADA
SYSCO ALLARD VILLE DE QUEBEC, QUEBEC, CANADA November, 2016 Infrared Inspection Report Sysco Allard 199 2e Avenue Ville de Quebec, QC, G1L 3A5 Company Contact Louis Grenier Project: C041116 2605 CHARTER
More informationAcid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company
Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall
More informationGETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP
GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by
More information10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095
10 DRIP NOZZLE WATERING DRIP KIT Model 93261 / Model ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
More informationBS Series Basket Strainer
BS Series Basket Strainer Operating, Installation, & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems. Dated 04-26-12 PRESSURE DROP SIMTECH strainers are engineered to offer the lowest
More informationLUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS
AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight
More informationTri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS
Tri-Safem Model I1 Regulator INSTRUCTIONS and PARTS USER RESPONSIBILITY This equipment will perform in conformity with the description thereof contained In this manual and accompanying labels andlor inserts
More informationInstallation Instructions JATCO Environmental Protection Tank Model J-7000
Installation Instructions JATCO Environmental Protection Tank Model J-7000 The JATCO Environment Tank must be installed at a level which will allow the waste liquids to be disposed of to gravity flow into
More informationPORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS
PORTABLE 5 GALLON AIR TANK MODEL 472 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND
More informationInstallation Instructions JATCO Environmental Protection Tank Model J-5000CX
Installation Instructions JATCO Environmental Protection Tank Model J-5000CX The JATCO Environment Tank must be installed at a level which will allow the waste liquids to be disposed of to gravity flow
More informationCLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.
Page 1 of 7 CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD 1. SCOPE 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems. 1.2 The piping system as used herein is
More informationInstruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.
Instruction Manual Hydraulic Punch Driver 902-483 LIMITED 1 YEAR WARRANTY We make every effort to assure that its products meet high quality and durability standards, and warrant to the original purchaser
More informationTHE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM
THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM What is pressure drop in a compressed air utility? Pressure drop is a term used to characterize the reduction in air
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationNitrogen Supply System
ATMOSCOPE Nitrogen Supply System NS500 Users Guide Copyright 2001 EDSYN, INC. ATMOSCOPE Nitrogen Supply Systems TABLE OF CONTENTS Introduction............................. 3 General Information.......................
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationOperating Manual. Model MP-4R and MP-4RSS MULTI-PAK TM RESCUE AIR CARTS Manual No. PAK013 (Rev 1 January 2001)
Model MP-4R and MP-4RSS MULTI-PAK TM RESCUE AIR CARTS Manual No. PAK013 (Rev 1 January 2001) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757)
More informationCOMPRESSED AIR SYSTEMS AND ENERGY SAVINGS
COMPRESSED AIR SYSTEMS AND ENERGY SAVINGS Denis Cooke, Denis Cooke & Associates Pty Limited www.decoa.com.au Phone (02) 871 6641 March 1994 DISCLAIMER The author makes no warranties whatsoever in connection
More informationInstallation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series
Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator
More informationENS-200 Energy saving trainer
ENS-200 Energy saving trainer Find out about the essential aspects of energy efficiency in compressed air installations Save money Put it into practice Take care of the environment Get training www.smctraining.com
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationSUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE
Page 1 of 6 A. PURPOSE AND SCOPE This procedure establishes safe working practices for handling sulfur hexafluoride (SF 6 ) gas and release minimization practices. This document also specifies methods
More informationNote: You will need a full tank of CO2 for connection and leak testing! Kit Number
Owners Manual Design Engineering Inc. CryO2 Cryogenic Tank Installation Kit To be used with CryO2 components only! Persons experienced in the installation and proper operation of Performance systems like
More informationInstallation Instructions Air Compressor Part # 2780, 2781
Note: It is essential that the operator of this product read and understand the contents of this manual before installing and using this product. Parts Included Qty Parts Included Qty Compressor 1 Coil
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationFRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System
FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System For inflating aircraft tires and all types of other vehicle tires and air operated devices Manual The Steelebrook Group Where Imagination
More informationAccu-Tab PowerBase 3012AT by Axiall Corporation
Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved
More informationPeriodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels
(Jan 2017) Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels CONTENTS 1. Application 2. Special Survey 2.1 Schedule 2.2 Scope
More informationNorrsken Family Booklet
Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation
More informationOperating Instructions in accordance with the Machines Directive 2006/42/EC
Lubricating Equipment Metering Technology for Grease and Oil High Pressure Hydraulic Customised Developments Operating Instructions in accordance with the Machines Directive 2006/42/EC Compressed air filling
More informationCylinder Tilt Saddle Instruction Manual
Cylinder Tilt Saddle Instruction Manual MODELS: SDT05, SDT10, SDT15, SDT25 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 - Fax: 816-448-2142 E-mail: sales@bvahydraulics.com
More information120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank
120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank PART NO. 20003 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
More information2.5 & 5.0 GALLON PRESSURE TANKS
2.5 & 5.0 GALLON PRESSURE TANKS Includes: MODEL 7025 MODEL 7026 MODEL 7027 MODEL 7028 2.5 Gallon Single Regulation (NON A.S.M.E.) 2.5 Gallon Dual Regulation (NON A.S.M.E.) 5.0 Gallon Single Regulation
More informationLUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010
LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants
More informationModel PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515
Model 2010 -PIV UL/FM Post Indicator Valve Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515 2 LAYOUT AND SITING At the design stage, it should be considered where valves
More informationANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS
Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series
More information1. CONDITIONS FOR USE 2. SAFETY
1. CONDITIONS FOR USE This micro abrasive blaster may only be operated: Indoors; Below 6500 ft above sea level altitude; Ambient air temperature between 40-105 F (5-40 C); Maximum relative humidity of
More informationOperating Manual CBA Series Cascade Breathing Air Assemblies
Manual No. WHP002 (Rev 5 January 2007) Operating Manual CBA Series Cascade Breathing Air Assemblies AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967
More informationACCU-PULSE Installation and Operation Instructions
ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse
More informationManual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering
Manual Bypass Feeder Chemical Addition and Filtering Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 918-686-6211 Fax: 918-686-6212 www.advantagecontrols.com
More informationI have to say that I had no idea about compressors. That means it s easy for everybody.
D I S C L A I M E R O F L I A B I L I T Y A N D W A R R A N T Y This publication describes the author s opinions regarding the subject matter herein. The author and publisher are not rendering advice or
More informationINSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures
INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..
More informationMoveRoll Conveyor Operating and Maintenance Manual
MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.
More informationHigh Pressure Inlet Kits for CONCOA BlendMites and BlendMasters
ADI 3210-A ADI 3210-A Certified ISO 9001 Certified ISO 9001 High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters Warning: An appropriately sized pressure relief device downstream of the regulator
More informationINJECTION ODORIZING SYSTEMS : DOSAODOR TYPE
0198GB Rev. 02 - Page 1/6 - English INJECTION ODORIZING SYSTEMS : DOSAODOR TYPE The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure
More informationSEMIC05 Installing mechanical equipment
Overview This unit identifies the competences you need to install mechanical equipment, in accordance with approved procedures. This will require you to survey the site for the proposed installation, and
More informationFlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number
3M Water Filtration Products FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number 56123-06 Installer: Please leave this manual with owner/operator. End User: Please retain for
More informationSAFETY TRAINING LEAFLET 06 CARBON DIOXIDE
SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE Doc 23.06/18 EUROPEAN INDUSTRIAL GASES ASSOCIATION AISBL AVENUE DES ARTS 3-5 B 1210 BRUSSELS Tel: +32 2 217 70 98 Fax: +32 2 219 85 14 E-mail: info@eiga.eu Internet:
More informationNB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationeasycomposites SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER
TM easycomposites share the knowledge SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER 26L Vacuum Degassing Chamber 26L Starter Vacuum Degassing
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationAIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS
AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV ENVIRONMENT ADDING VALUE SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS Air saving products INDEX Chapter Content
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationHYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)
Form No. 102897 Operating Instructions for: HB443 HB444 HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg) Definition: A devise that raises the inlet pressure to
More informationAIR STAPLER MODEL: CSG1C Part No
AIR STAPLER MODEL: CSG1C Part No. 3110375 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.27 cfm
More informationVERTICAL AIR COMPRESSORS
VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical
More informationCOMPRESSED AIR TEXTILES ENERGY EFFICIENCY
TEXTILES ENERGY EFFICIENCY GUIDANCE NOTE 01 COMPRESSED AIR Compressed air often accounts for more than 10% of textile companies annual electricity use. It is referred to as the forgotten utility, as the
More informationSYSCO FOODS BAHAMAS FOOD SERVICE NASSAU, BAHAMAS
SYSCO FOODS BAHAMAS FOOD SERVICE NASSAU, BAHAMAS January, 2019 Infrared Inspection Report Sysco Bahamas Foods Gladstone Road Nassau, Bahamas Company Contact Eddie O Connor Project: 02300119 2605 CHARTER
More informationUnderstanding gas safety
Level: 3 Credit value: 15 URN: Y/502/8485 Unit aim This unit aims to provide learners with the knowledge and understanding of the gas safety requirements for working in the gas industry. Learning outcomes
More informationRULES PUBLICATION NO. 119/P
RULES PUBLICATION NO. 119/P PERIODIC SURVEYS OF FUEL INSTALLATIONS ON SHIPS OTHER THAN LIQUEFIED GAS CARRIERS UTILIZING GAS OR OTHER LOW FLASH POINT FUELS 2019 January Publications P (Additional Rule Requirements)
More informationAIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064
AIR HAMMERS MODEL NO: CAT138/CAT139 PART NO: 3120152 /3120153 OPERATING & MAINTENANCE INSTRUCTIONS GC064 INTRODUCTION Thank you for purchasing this CLARKE Air Hammer. Before attempting to use this product,
More informationBudget Range Operators Handbook
Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk
More informationVessel Installation and Operating Manual
For In-ground and Aboveground Pools Vessel Installation and Operating Manual Important Safety Information Please read this manual prior to installation. Nature 2 Express is designed to sanitize in-ground
More information