The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
|
|
- Lambert Reeves
- 5 years ago
- Views:
Transcription
1 General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal (meets UL NEMA,, X, P,, ). Wide standard operating temperature range: 0 C to +00 C (standard type). s with fluoro-rubber available for greater resistance to chemicals. Block method also reduces downtime for maintenance. DPDT, double-break models available for complex s. by UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for information on approved model.) Be sure to read Safety Precautions on page to and Safety Precautions for All Limit Switches. Number Structure Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) DA-@@@@N (Set model number) () () () () Receptacle box : /- NPT (SPDT, double-break) : /- NPT (DPDT, double-break) : G / (SPDT, double-break) : G / (DPDT, double-break) () Switch Box : SPDT, double-break, without indicator : SPDT, double-break, neon lamp E : SPDT, double-break, LED ( VDC, leakage current:. ma) : DPDT, double-break, simultaneous, without indicator 7 : DPDT, double-break, sequential, without indicator * 9 : DPDT, double-break, center neutral, without indicator * L : DPDT, double-break, simultaneous, neon lamp P : DPDT, double-break, simultaneous, LED *. Use the DA-007N Special Head. *. Use the DA-008N Special Head. Note: Fluoro-rubber sealed type is also available. () Head 0 : Roller lever, standard 0 : Roller lever, high-sensitivity 0 : Roller lever, low torque 0 : Roller lever, high-sensitivity, low torque 0 : Roller lever, maintained 7 : Roller lever, sequential 8 : Roller lever, center neutral 0 : Side plunger, standard 07-V : Side plunger, vertical roller 07-H : Side plunger, horizontal roller 08 : Side plunger, adjustable 09 : Top plunger, standard 0 : Top plunger, roller : Top plunger, adjustable : Flexible rod, spring wire : Flexible rod, plastic rod : Flexible rod, cat whisker : Flexible rod, coil spring
2 Ordering Information SPDT, Double-break Switches Actuator Set model number Receptacle box G / Conduit Indicator Without indicator With neon lamp indicator (AC) With LED indicator (DC) Standard DA-0N UL, CSA DA-0N UL, CSA DA-E0N High-sensitivity DA-0N UL, CSA DA-0N UL, CSA DA-E0N Roller lever * Low-torque DA-0N UL, CSA High-sensitivity, Low-torque DA-0N UL, CSA DA-0N UL, CSA --- Maintained * DA-0N UL, CSA DA-0N UL, CSA DA-E0N Standard DA-0N UL, CSA Side plunger Vertical roller DA-07-VN UL, CSA DA-07-VN UL, CSA DA-E07-VN Horizontal roller DA-07-HN UL, CSA DA-07-HN UL, CSA --- Adjustable DA-08N UL, CSA DA-08N UL, CSA DA-E08N Standard DA-09N UL, CSA DA-09N UL, CSA --- Top plunger Roller DA-0N UL, CSA DA-0N UL, CSA --- Adjustable DA-N UL, CSA DA-N UL, CSA --- Spring wire DA-N UL, CSA DA-N UL, CSA DA-EN Plastic rod DA-N UL, CSA DA-N UL, CSA DA-EN Flexible rod Cat whisker DA-N UL, CSA DA-N UL, CSA DA-EN Coil spring DA-N UL, CSA DA-N UL, CSA DA-EN Note:. Switches are also available NPT s. The model numbers correspond as follows: (Examples) G / Conduits /- NPT Conduits DA-@@@N DA-@@@N DA-@@@N DA-@@@N. Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is 0 to +0 C.) Add -F to the model number. (Example: DA-0N becomes DA-0N-F.) Ask your nearest OMRON representative for details. *. The lever is not included with the Roller Level s. Select the lever from those listed in this data sheet and order it separately (refer to Levers on page ). *. The Maintained Switches have a lock mechanism for the switch and thus use a Fork Lever Lock.
3 DPDT, Double-break Switches Receptacle box G / Conduit Indicator Without indicator With neon lamp indicator (AC) With LED indicator (DC) Actuator Standard DA-0N UL, CSA DA-L0N DA-P0N High-sensitivity DA-0N UL, CSA Low-torque DA-0N UL, CSA Roller lever * High-sensitivity, Low-torque DA-0N UL, CSA Maintained * DA-0N UL, CSA Sequential DA-77N UL, CSA Center neutral DA-98N UL, CSA Standard DA-0N UL, CSA Side plunger Vertical roller DA-07-VN UL, CSA Horizontal roller DA-07-HN UL, CSA Adjustable DA-08N UL, CSA Standard DA-09N UL, CSA Top plunger Roller DA-0N UL, CSA DA-L0N DA-P0N Adjustable DA-N UL, CSA Spring wire DA-N UL, CSA Plastic rod DA-N UL, CSA Flexible rod Cat whisker DA-N UL, CSA Coil spring DA-N UL, CSA Note:. Switches are also available NPT s. The model numbers correspond as follows: (Examples) G / Conduits /- NPT Conduits DA-@@@N DA-@@@N DA-@@@N DA-@@@N. Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is 0 to +0 C.) Add -F to the model number. (Example: DA-0N becomes DA-0N-F.) Ask your nearest OMRON representative about delivery times and prices. *. The lever is not included with the Roller Level s. Select the lever from those listed in this data sheet and order it separately (refer to Levers on page ). *. The Maintained Switches have a lock mechanism for the switch and thus use a Fork Lever Lock. Receptacle box Individual Parts Type G/ * /-NPT * Appearance SPDT double-break DA-000N UL, CSA DA-000N UL, CSA DPDT double-break DA-000N UL, CSA DA-000N UL, CSA *. M-screw (standard ) *. 0-UNF-screw (standard )
4 Switch Box Appearance Indicator Without indicator With neon lamp indicator (AC) With LED indicator (DC) SPDT doublebreak DA-000N UL, CSA DA-000N UL, CSA DA-0E00N (Without indicator lamp) DPDT doublebreak Simultaneous Sequential DA-000N UL, CSA DA-0L00N --- DA-0P00N DA-0700N UL, CSA (Without indicator lamp) Center neutral DA-0900N UL, CSA Heads Roller lever * Appearance Standard DA-000N UL, CSA High-sensitivity DA-000N UL, CSA Low-torque * DA-000N UL, CSA Sequential : * DA-007N UL, CSA Center neutral : * DA-008N UL, CSA Maintained DA-000N UL, CSA Top plunger Appearance Type Standard DA-0009N UL, CSA Roller DA-000N UL, CSA Adjustable DA-00N UL, CSA Standard DA-000N UL, CSA Side plunger Vertical roller DA-0007-VN UL, CSA Horizontal roller DA-0007-HN UL, CSA Spring wire DA-00N UL, CSA Side adjustable DA-0008N UL, CSA *. Levers for Roller Lever Switches are optionally available. Select the lever from those listed in this data sheet and order (refer to Levers on page ). *. The DA-C00 adjustable roller lever is too heavy and long for these heads and it should not be used or mechanical malfunction will result. *. These heads cannot be used for simultaneous s. Flexible rod Plastic rod DA-00N UL, CSA Cat whisker DA-00N UL, CSA Coil spring DA-00N UL, CSA
5 Levers Actuator DA-A00 DA-A0 Roller Lever DA-A0 DA-A0 DA-B0 DA-C00 Adjustable Roller Lever DA-D00 Resin Loop Lever DA-F00 DA-E0 DA-E0 Fork Lever Lock DA-E0 DA-E00 Note: Refer to page for Lever shapes and applicable models. Specifications Standards Agency Standard File No. UL UL08 E77 CSA CSA C. No. LR7 CCC (CQC) GB Note: Ask your OMRON representative for information on approved models. Ratings Ratings for Indicators Type SPDT doublebreak (with/ without indicator) DPDT doublebreak (without indicator) DPDT doublebreak (with indicator) Rated voltage VAC * 0 VAC * 80 VAC 00 VAC 8 VDC VDC 0 VDC VDC * 0 VDC * VAC 0 VAC 80 VAC 00 VAC VDC 0 VDC VDC 0 VAC VAC 0 VAC VDC VDC 8 VDC Non-inductive load (A) Inductive load (A) Resistive load Inductive Motor load load load NC NO NC NO NC NO NC NO Classification SPDT doublebreak DPDT doublebreak Indicator Neon lamp DA-000N Rated voltage VAC, 0 VAC LED DA-0E00N VDC Neon lamp DA-0L00N VAC, 0 VAC LED DA-0P00N 8 VDC Leakage current Approx. 0.7 ma Approx.. ma Approx. ma Approx.. ma Internal resistance 0 kω kω 0 kω --- * For those with indicators, refer to the following rated voltages. Item Inrush current Type Normally closed Normally open SPDT, Double-break Without indicator 0 A max. 0 A max. With indicator DPDT, Double-break Without indicator With indicator Note:. The above current ratings are for steady-state current.. Inductive loads have a power factor of 0. min. (AC) and a time constant of 7 ms max. (DC).. loads have an inrush current of 0 times the steady-state current.. Motor loads have an inrush current of times the steady-state current.
6 Standard Ratings UL/CSA A00 (SPDT, Double-break, Without Indicator) Rated voltage 0 VAC 0 VAC 80 VAC 00 VAC Carry current 0 A A00 DA-@@@N (SPDT, Double-break, With Neon ) Rated voltage 0 VAC 0 VAC Carry current 0 A B00 DA-@@@N (DPDT, Double-break, Simultaneous Operation) DA-@7@@N (DPDT, Double-break, Sequential Operation) DA-@9@@N (DPDT, Double-break, Center Neutral Operation) Rated voltage 0 VAC 0 VAC 80 VAC 00 VAC Carry current A CCC (GB08.) Current (A) Volt-amperes (VA) Make Break Make Break ,00 70 Current (A) Volt-amperes (VA) Make Break Make Break 0 0 7,00 70 Current (A) Volt-amperes (VA) Make Break Make Break Applicable category and ratings AC- A/ VAC ,00 0 Characteristics Degree of protection (reference ) Durability * Operating speed Mechanical: * Electrical: Operating Mechanical: frequency Electrical: Rated frequency Insulation resistance Contact resistance Temperature rise Between terminals of same polarity Dielectric strength Between current-carrying metal parts and ground Between each terminal and non-currentcarrying metal part IP7 and NEMA,,, X,, P,, and SPDT, double-break, roller lever: 0,000,000 s min. DPDT, double-break, roller lever: 0,000,000 s min. SPDT, double-break: for VAC, 0 A resistive load:,000,000 s min. DPDT, double-break: for VAC, A resistive load: 70,000 s min. mm/s to m/s (in case of DA-0N roller lever model) 00 s/minute 0 s/minute 0/0 Hz 00 MΩ min. (at 00 VDC) between terminals of the same polarity, between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal part mω max. (initial value) 0 C max.,000 VAC, 0/0 Hz for min.,00 VAC, 0/0 Hz for min. *,00 VAC, 0/0 Hz for min. * Pollution degree (operating environment) Protection against electric shock Class I (with grounding terminal) Vibration resistance Malfunction: * 0 to Hz,.-mm double amplitude Destruction:,000 m/s min. Shock resistance Malfunction: * Ambient operating humidity Weight SPDT, double-break, roller lever: 00 m/s min. DPDT, double-break, roller lever: 00 m/s min. % to 9%RH (with no icing) Approx. 90 g (in case of DA-0N) Note: The above figures are initial values. *. Excluding maintained models. *. The values are calculated at an operating temperature of + C to + C, and an operating humidity of 0% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *.,00 VAC is applied to the indicator lamp type. *. Not including Flexible rods (cat whisker, plastic rod, coil spring, and spring wire types). Plunger, flexible rod * Item Type Roller lever * With indicator Ambient temperature 0 C to +00 C 0 C to +00 C 0 C to +80 C *. Excluding low-torque and high-sensitivity models. *. Including roller lever low-torque and high-sensitivity operating models.
7 Engineering Data Electrical Durability (SPDT Double-break) (Ambient temperature: + C to + C; ambient humidity: 0% to 70%RH) Durability (x 0 s) VAC 0 VAC 80 VAC Operating frequencies: 0 s/min, cosφ = Durability (x 0 s) VAC 0 VAC 80 VAC Operating frequencies: 0 s/min, cosφ = Switching current (A) Electrical Durability (DPDT Double-break) Durability (x 0 s) VAC 0 VAC 80 VAC Operating frequencies: 0 s/min, cosφ = Durability (x 0 s) Switching current (A) VAC 0 VAC 80 VAC Operating frequencies: 0 s/min, cosφ = Switching current (A) 0 Switching current (A) Structure and Nomenclature Structure (DPDT Double-break) Head With the Roller Lever and Side Plunger Switches, the direction of the switch head can be varied to any of the four directions by loosing the roller lever switch screws at the four corners of the head. The Roller Lever Switch employs a system which allows selection of the of only one side (left or right) or both sides without use of any tools. Operating Position Mark (arrow) Bearings The copper-alloy bearings ensure long life expectancy. Receptacle The plug-in type receptacle provides adequate space for wiring. Conduit Opening *, * G / threads featuring high sealing property are used. (Refer to Limit Switch Connectors for details on SC connectors). A terminal box with /-NPT threads is also available on request. Sealed Gasket The employed full-cover method prevents the gasket from direct exposure to oil or water spray. Roller The roller actuator is made of hardened stainless steel and excels in resistance to wear. Lever With the Roller Lever Switch, the lever can be installed anywhere in a 0 range (80 if the lever is reversed and attached to the shaft). Oil Seal Improved sealing property is ensured with a double-seal construction (a oil seal plus an X-ring seal). Switch Box Boasts long life expectancy (0 million mechanical s or more with the -pole Double-break Switches and 0 million mechanical s or more with the DPDT Double-break Switches). Ground Terminal Screw A ground terminal is provided to enhance safety. Switch Box Screw A Phillips screw is used to secure the switch housing for ease of use, and features a measure to prevent the screw from coming off. Easy-maintenance Block Mounting Block makes it possible to easily assemble or disassemble the head, switch body, and receptacle of the by tightening or loosening the attached screws. Actuator Switch box Head Receptacle Note:. NBR is used in rubber components. Fluoro-rubber sealed types use fluoro-rubber.. For Roller Levers, there is some lever play in the free position (about mm), but this is due to the structure of the head and does not interfere with performance. *. A Receptacle and Terminal Box with /-NPT threads are also available for the North America market. *. The thread indication has been changed from PF/ to G/ accompanying the JIS B 00 revision. This changes applies only to the indication; thread sizes and pitches have not been affected. 7
8 Contact Forms (Switch Boxes) STDP Double-break Switches Type Contact model Without indicator With neon lamp indicator * With LED indicator * DA-000N DA-000N DA-0E00N Operating pattern NC/NO snap-action Unit Internal Circuits Unit Internal Circuits - - Energized Neon lamp Rectifier stack LEDs Resistor Resistor * Switches with indicators are factory-set to light when the switch is not operated. DTDP Double-break Switches Each of these Switches can be used to replace two limit switches in applications, such as high-speed control in machine tools and switching motors between forward and reverse, that previously required limit switches. This simplifies wiring, saves space, and reduces costs. Type Without indicator Contact model With neon lamp indicator * With LED indicator * Operating pattern Remarks NC/NO snap-action, simultaneous DA-000N DA-0L00N DA-0P00N Energized Head is compatible with double-break head. Can be switched for on both sides of actuator. Stroke Energized NC/NO snap-action, sequential (-step ) DA-0700N Use the DA-007N Special Head. Stroke Energized - NC/NO snap-action, central neutral DA-0900N Use the DA-008N Special Head. Left Free position Right Item Without indicator With neon lamp indicator * With LED indicator * DA-000N DA-0L00N DA-0P00N DA-0700N DA-0900N Contact form internal circuit ---- Neon lamp Resistor Rectifier stack Constant current diode LED * Switches with indicators are factory-set to light when the switch is not operated, but the setting can be changed to light for (dotted lines). 8
9 Dimensions and Operating Characteristics (Unit: mm) Set Numbers (The box in a model number indicates the switch box type.) Roller Lever Switches Note: Levers of the side rotary type are optionally available. Standard DA-@0N, DA-@0N High-sensitivity DA-@0N, DA-@0N Low-torque DA-@0N, DA-@0N High-sensitivity/Low-torque DA-@0N, DA-@0N Sequential Operation DA-@7N R. R.. 9.±0. Four, M (length: ) 7. dia dia. 9.± Two, M (length: 0) G/ Two, M (depth: 0) screws for back- Center Neutral Operating DA-@8N Maintained DA-@0N, DA-@0N Four, M (length: ) 7. dia R dia. 9.± R.. 9.±0. Two, M (length: 0) G/ Two, M (depth: 0) screws for back- Note: Unless otherwise specified, a tolerance of ±0. mm applies to all dimensions. Operating characteristics SPDT Double-break DPDT Double-break Note: The figures in the parentheses are average values. Operating force OF max. 0.9 N m 0.9 N m 0. N m 0. N m 0.9 N m 0.9 N m 0.9 N m 0. N m 0. N m 0.9 N m 0.9 N m 0.9 N m Release force RF min. 0.0 N m 0.0 N m N m 0.0 N m N m 0.0 N m Pretravel PT max. ( ) 7 ( ) ( ) 7 ( ) (0 ) ( ) 7 ( ) ( ) 7 ( ) (0 ) -stage: (0 ) -stage: 9 ( ) 0 (7 ) Overtravel OT min Movement Differential MD max. ( ) ( ) ( ) ( ) (0 ) 7 ( ) ( ) 7 ( ) ( ) (0 ) ( ) ( ) 9
10 Side Plunger Switches Standard Vertical Roller R. R. dia.x stainless steel roller R. R. Four, M (length: ). 9.±0.. 9.±0. 9 Stainless steel plunger.. 0 dia dia. 9.± Two, M (length: 0) Four, M (length: ) dia. 9.± PT Two, M (length: 0) PT OP G/ G/ OP 7.. Two, M 8 (depth: 0) screws for back Two, M (depth: 0) screws for back- Horizontal Roller DA-@07-HN DA-@07-HN Adjustable DA-@08N DA-@08N dia.x stainless steel roller R. R. R. R.. 9.±0.. 9.±0. Four, M (length: ) dia. 9.± Four, M (length: ) PT Two, M (length: 0) 9 G/ OP M x (length:) Allen-head bolt PT OP dia. 9.± Two, M (length: 0) G/ Two, M (depth: 0) screws for back- 7. Two, M (depth: 0) screws for back- SPDT Double-break DPDT Double-break Operating characteristics DA-@0N DA-@07-HN DA-@07-VN DA-@08N DA-@0N DA-@07-HN DA-@07-VN DA-@08N Operating force OF max. 9. N 9. N 9. N 9. N 9. N 9. N 9. N 9. N Release force RF min..90 N.90 N.90 N.90 N.90 N.90 N.90 N.90 N Pretravel PT max.. mm. mm. mm. mm. mm. mm. mm. mm Overtravel OT min.. mm. mm. mm. mm. mm. mm. mm. mm Movement Differential MD max. 0. mm 0. mm 0. mm 0. mm.0 mm.0 mm.0 mm.0 mm OP * ± mm ± mm ± mm to 7. mm ±mm ± mm ± mm to 7. mm * Operating position Top Plunger Switches Standard DA-@09N DA-@09N R. R. 0 dia. Stainless steel plunger PT. 9.±0. Four, M (length: ) 7 OP dia. 9.± Two, M (length: 0) G/ Two, M (depth: 0) screws for back- Roller Plunger DA-@0N DA-@0N R. R. dia.x stainless steel roller. 9.±0. PT Four, M (length: ) OP dia. 9.± Two, M (length: 0) G/ Two, M (depth: 0) screws for back- Adjustable DA-@N DA-@N R. R. M x (length:) Allen-head bolt PT. 9.±0. Four, M (length: ) OP dia. 9.± Two, M (length: 0) G/ Two, M (depth: 0) screws for back- SPDT double-break DPDT double-break Operating characteristics OF max. RF min. PT max. OT min. MD max. DA -@09N 7. N.90 N. mm. mm 0. mm ± OP * mm * Operating position DA -@0N 7. N.90 N. mm. mm 0. mm ± mm DA -@N 7. N.90 N. mm. mm 0. mm. to mm DA -@09N 7. N.90 N. mm. mm.0 mm ± mm DA -@0N 7. N.90 N. mm. mm.0 mm ± mm Note: A Fork Lever Lock can be used with DA-@@0N models only. DA -@N 7. N.90 N. mm. mm.0 mm. to mm 0
TURQUOISE SWITCHES ABJ (BJ) SWITCHES
Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationPressure switch for gas and air
Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4
More informationPressure Switch for gas and air GGAO-A4
Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationNO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice
NO: REL-149 PRODUCT: PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice G8P PCB Power Relays to be DISCONTINUED April 30, 2015 Due to a diminishing global demand for the G8P series PCB Power
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationPrewired position switches FA series
Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationDual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series
Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationRoHS. WS Series Snap Action Switch. Specifications. Part Number Configurator
Applications / Markets HVAC Electrical Housewares Floor Care Appliances Specifications White Goods Vending Machines Features & Benefits Medical Equipment RoHS Contact Rating: 0.5A @ 42VDC 1A @ 24VDC 2A
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationSafety Shutoff Valves MVD/6 Series MVDLE/6 Series
Safety Shutoff Valves /6 Series /6 Series Normally closed safety shutoff valve with the following approvals. UL Listed UL 49 File # MH16 CSA Certified ANSI Z1.1 CSA 6. Marked C/I File # LR 111 FM Approved
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationSEALED CONNECTORS FOR THE LIMIT SWITCHES
SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications
More informationLimit switches OsiSense XC Special For material handling applications, type XC1 AC
Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics
More informationPneumatic pressure switch 20DD
Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationDual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series
Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationQPL... Pressure Switches. Siemens Building Technologies HVAC Products
7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch
More informationDual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationINSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
More informationDual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationSV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified
More informationPegasus Series Amphenol Pcd
Pegasus Series Amphenol Pcd Amphenol Pcd is one of the world s leading suppliers of interconnect products for Military, Commercial Aerospace and Industrial applications. Located north of Boston in Beverly,
More informationPressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
More informationNorth American Pressure Switches
Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are
More informationACCESSORIES. Standard packing
ACCESSORIES HC RELAYS (Sockets and Terminal ) FEATURES. HC Relay Sockets In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Plug-in type, type, and wrapping type
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationSocket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11
Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double
More informationPRESSURE SWITCHES Bulletin 8757
PRESSURE SWITCHES Bulletin 8757 September 2013 Pressure switches are used with Automatic Shutoff Valves or solenoid valves to interrupt fuel fl ow in the event of fuel or air failure. They are also used
More informationPressure switch and Thermostat Type KPS
MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch and Thermostat Type KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has
More informationValve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationDual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604
Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21
More informationPressure switch and Thermostat KPS
Data sheet Pressure switch and Thermostat KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More informationDual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
More informationReferences 6 k thermal overload relays, adjustable from 0.11 to 16 A
s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationSPECIFICATIONS CAPACITY
DMV-ZRD(LE)/6 SERIES Installation Instructions SPECIFICATIONS DMV-ZRD/6 DMV-ZRDLE/6 Two normally closed safety shutoff valves in one housing. V1 and V2 are fast opening, fast closing. Two stage and adjustable
More informationNC MAGNETIC FLOAT SWITCHES FOR LIQUIDS
NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS Flow Pressure Level Temperature measurement monitoring control N Available Materials: Brass, Stainless Steel, Buna-N, Polypropylene and PVC Maximum Pressure: 400
More informationO.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA
HPSV 10020/604 High Pressure Safety Shutoff Valve Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Installation
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More information120 Series Explosion-Proof Pressure and Differential Pressure Switches
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K SIL2 Certified UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please
More informationGM-7000 Series CE Approved Gas Control Valve
Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
More informationO.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA
S06 & S02 Valve Proving System Installation Instructions USA CDN Table of Contents Table of Contents... Page 1 Approvals... Page 1 Attention... Page 1 Specification... Page 2 Mounting.... Page 3 Wiring...
More informationVALVES ISO 5599/1, SERIES IPV-ISV
VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.
More informationPart I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read all instructional
More informationSeries variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )
Series variation High damping effect and types of materials Model / appearance Metering valve with silencer Model no. SMW-6 SMW-8 FMS-M SMW- SMW- (R) M M /8 / /8 / / / / 6 8 Effective sectional area (mm
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationInductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm
Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated
More informationModel range*1) Switching pressure difference
Pneumatic pressure switch electromechanical actuated -...00 bar, G/2 Microswitch with gold plated contacts Intrinsically safe operation Electrical connection: connector acc. to IN EN 7530-803 (form A)
More informationXML Electromechanical Pressure Switches
Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential:
More informationDifferential pressure switch MP 54, MP 55 and MP 55A
Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationLTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.
LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
More informationFeatures. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts
FLOAT LEVEL SWITCH The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine Trafag
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationG92 Series BASOTROL Automatic Pilot Gas Valve
Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationSPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION
SV/614 Installation Manual -P/N 80128 - Ed. 01/08 SV-(DLE) 10../614 Safety Shutoff Valve with Proof of Closure Installation Instructions 1 6 SV/614 SV-DLE/614 SPECIFICATIONS Normally closed automatic shutoff
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationRelative pressure switch type 521
Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationOFFICINE OROBICHE S.p.A. 1/9
OFFICINE OROBICHE S.p.A. 1/9 INSTRUCTIONS MANUAL FOR LEVEL SWITCHES SERIES 7000 mod. 7250 AND 7400 Electric 1. INSTRUMENT DESCRIPTION Series 7000 level switches have been designed for external lateral
More informationPart I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K, H122P U N I T E D E L E C T R I C C O N T R O L S Installation and Maintenance Instructions
More informationElectronic relative and differential pressure switch type 616
Electronic relative and differential pressure switch type 616 Pressure range 0... 0.1 25 bar The switching points of the pressure switch type 616 can be potentiometer adjusted by the customer, or set in
More informationVRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES
GAS VALVES VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES APPLICATION PRODUCT HANDBOOK The VRB00 Series class B servo regulated combination valves are used for control and regulation of gaseous
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationSolenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners
7 634 VGS1... with AGA67 connector VGS2... with AGA67 connector Solenoid gas valve VGS The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners The VGS and
More informationData sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782
Data sheet Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E2.02 520B0782 Survey Type KPS pressure switches 1. Standard pressure switches Range Further -1 0 10 20 30 40 50 60 bar P e Type
More informationSimple Set. Pressure Independent Control Valves 2 Way 1/2-2
The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control
More informationC645A-E Pressure Switches
C645A-E Switches FEATURES PRODUCT DATA C645A,B,D,E GENERAL C645A,B with Window C645C The C645 pressure switches are safety devices used in positive-pressure or differential-pressure systems to sense gas
More information