Renewables. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 17 July 2012
|
|
- Eunice Hawkins
- 6 years ago
- Views:
Transcription
1 Renewables Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions Issue 17 July 2012 IMPORTANT NOTE TO THE INSTALLER Read these instructions before commencing installation. Unvented The relevant regulations are: England and Wales Building Regulation G3, Scotland Technical Standard P3, N Ireland Building Regulation Part F with these instructions, with the householder for future reference.
2 CONTENTS PAGE CONTENT 2 Introduction 5 Siting the unit 6 General Installation 7 Discharge Arrangement 12 Solar Coil Installation 13 Solar High Limit 14 S-Plan Wiring Schematics 15 Y-Plan Wiring Schematics Pre-Plumbed Wiring Schematics 18 Pre-Plumbed Installation 20 Commissioning & Servicing 21 Fault Finding & User Instructions 22 Guarantee - Terms & Conditions 26 Commissioning Check Sheet 27 Service Record INTRODUCTION 2
3 STORAGE PRIOR TO INSTALLATION HANDLING PRODUCT WATER SUPPLY ELECTRIC SUPPLY 2 heat resistant control set Incoloy long life 3 kw immersion heater relief valve Dual thermostat Acetal tundish - 12 ltr vessel - 18 ltr vessel High Limit thermostat Installation & Maintenance Instructions 3
4 COMPONENT CONTENT TABLE Slimline Direct Models (Electric) Slimline Indirect Models Direct Models Indirect Models Ecocyl Direct Models Ecocyl Indirect Models Solar Direct Models Solar Indiect Models Indirect pre-plumbed models - 1 zone heating Indirect pre-plumbed models - 2 zone heating Solar indirect pre-plumbed models - 1 zone heating Solar indirect pre-plumbed models - 2 zone heating Installation & Maintenance Instructions TP5000 TP9000 Robo-Kit Sensor pocket retaining bungs Single High Limit Stat Dual Thermostat Two Port Valve Immersion Heater (Indirect) Immersion Heater (Direct) Expansion vessel Tundish Temp & Pressure relief valve. Inlet Control set 4
5 SITING THE UNIT The immersion heaters are 375mm long and care should be taken to ensure that they can be withdrawn for servicing if SCHEMATIC DIAGRAM HOT OUTLET SECONDARY RETURN CIRCUIT ( 210, 250 & 300 L SIZES ) TEMPERATURE & PRESSURE RELIEF VALVE EXPANSION RELIEF VALVE Inlet Control Set BRONZE PUMP NON RETURN VALVE TUNDISH NON RETURN VALVE PRESSURE REDUCING VALVE ISOLATING VALVE COLD MAIN BALANCED COLD CONNECTION BOILER FLOW 2 PORT VALVE DUAL STAT COLD INLET VIA DRAIN EXPANSION VESSEL WITH WALL BRACKET Notes: inlet control set. BOILER RETURN IMMERSION HEATER secondary return boss and the secondary return above the drain elbow. 5
6 GENERAL INSTALLATION servicing. CONNECTING TO THE CYLINDER ensuring the tube end fully bottoms on the connection recess. Smear the outer wall Note: No BALANCED COLD CONNECTION PRIMARY COIL CONNECTIONS FOR INDIRECT UNITS thermostatic control. Uncontrolled heat sources such as some AGA s, back boilers, solid fuel stoves, etc. are NOT SUITABLE. Please SECONDARY CIRCULATION IMMERSION HEATERS 2 ELECTRICAL CONNECTIONS Cold Mains In Turn to test Balanced Cold Connection (expansion vessel not to scale) Expansion Relief Connection Expansion Relief to Tundish Outlet to Cylinder 6
7 DISCHARGE ARRANGEMENT Note: The discharge will consist of rainwater goods may be damaged by such discharges. allowed to be installed in soil stacks discharge from T&P may continue If used follow guidance on given in G3 Building Regulations. 90 o is also not recommended. Any Discharge should be visible at the tundish. The tundish should be located such that any discharge is visible. In addition, domestic use within buildings and their curtilages. arrangements are: seal. maintaining visibility. From Table 1: valve is: 9.0m. Subtract the resistance for 4 No. 22mm will be satisfactory. Table1 Size of discharge pipework Maximum length of straight pipe (no bends or elbows) 22mm Up to 9m 0.8m 28mm Up to 18m 1m 35mm Up to 27m 1.4m from the maximum length for each bend or elbow in the discharge pipe 7
8 Tribune HE Slimline Direct 22mm HOT DRAW - OFF 1 2 F PTRV BOSS 22mm SECONDARY RETURN (not always fitted. See table) SECOND IMMERSION HEATER (not always fitted. See table) mm COLD FEED WITH DIP PIPE TO DEFLECTOR IN BOTTOM OF CYLINDER D A B C G CODE HEIGHT DIAMETER A B C D G TDS N/F N/F 483 TDS N/F 858 TDS N/F 1046 TDS N/F 1234 TDS N/F 1484 TDS Tribune HE Slimline Indirect 22mm HOT DRAW - OFF 1 2 F PTRV BOSS 22mm SECONDARY RETURN (not always fitted. See table) DRY STAT POCKET 22mm COLD FEED WITH DIP PIPE TO DEFLECTOR IN BOTTOM OF CYLINDER F D A B C G CODE HEIGHT DIAMETER A B C D F G TIS N/F 483 TIS N/F 858 TIS N/F 1046 TIS N/F 1234 TIS N/F 1484 TIS All Dimensions are in mm and are of the cased unit.
9 Tribune HE Direct 22mm HOT DRAW - OFF 22mm SECONDARY RETURN (not always fitted. See table) 1 2 F PTRV BOSS SECOND IMMERSION HEATER (not always fitted. See table) 22mm COLD FEED WITH DIP PIPE TO DEFLECTOR IN BOTTOM OF CYLINDER D F mm 160mm CODE HEIGHT DIAMETER D F TD N/F N/F TD N/F 510 TD N/F 610 TD N/F 710 TD TD TD Tribune HE Indirect 22mm HOT DRAW - OFF 1 2 F PTRV BOSS 22mm SECONDARY RETURN (not always fitted. See table) SECOND IMMERSION HEATER (not always fitted. See table) DRY STAT POCKET 22mm COLD FEED WITH DIP PIPE TO DEFLECTOR IN BOTTOM OF CYLINDER F E D C B A CODE HEIGHT DIAMETER A B C D E F TI N/F N/F TI N/F N/F TI N/F N/F TI N/F N/F TI N/F 1150 TI TI All Dimensions are in mm and are of the cased unit. 9
10 Tribune HE ECOCYL Direct 22mm HOT DRAW - OFF 1 2 F PTRV BOSS 22mm SECONDARY RETURN (not always fitted. See table) SECOND IMMERSION HEATER (not always fitted. See table) mm COLD FEED WITH DIP PIPE TO DEFLECTOR IN BOTTOM OF CYLINDER D A B C G CODE HEIGHT DIAMETER A B C D G TDS60ECO N/F N/F 483 TDS90ECO N/F 858 TDS120ECO N/F 1046 TDS150ECO N/F 1234 TDS180ECO N/F 1484 TDS210ECO Tribune HE ECOCYL Indirect 22mm HOT DRAW - OFF 1 2 F PTRV BOSS 22mm SECONDARY RETURN (not always fitted. See table) DRY STAT POCKET 22mm COLD FEED WITH DIP PIPE TO DEFLECTOR IN BOTTOM OF CYLINDER F D A B C G CODE HEIGHT DIAMETER A B C D F G TIS60ECO N/F 483 TIS90ECO N/F 858 TIS120ECO N/F 1046 TIS150ECO N/F 1234 TIS180ECO N/F 1484 TIS210ECO All Dimensions are in mm and are of the cased unit.
11 Tribune HE Solar Direct 22mm HOT DRAW-OFF 22mm SECONDARY RETURN (not always fitted. See table) 1 2 F PTRV BOSS DRY STAT POCKET 22mm COLD FEED WITH DIP PIPE TO DEFLECTOR IN BOTTOM OF CYLINDER F E D C B A G CODE HEIGHT DIAMETER A B C D E F G TSS N/F TSS N/F TSS TSS TSS Tribune HE Solar Indirect 22mm HOT DRAW-OFF DRY STAT POCKET ½ F PTRV BOSS 22mm SECONDARY RETURN (not always fitted. See table) DRY STAT POCKET 22mm COLD FEED WITH DIP PIPE TO DEFLECTOR IN BOTTOM OF CYLINDER F E D C B A G H CODE HEIGHT DIAMETER A B C D E F G H TT N/F TT N/F TT TT TT All dimensions are in mm and are of the cased unit. N/F = Not Fitted 11
12 TRIBUNE HE DIRECT SINGLE COIL CYLINDER Detail for the installation of a Solar Unvented Direct cylinder. General Water 6 to 7 of this manual. Immersion Heaters Solar Connections TRIBUNE HE INDIRECT TWIN COIL CYLINDER UPPER COIL LOWER COIL: SOLAR INSTALLATION make use of the solar coil. 12
13 TYPICAL SCHEMATIC WIRING DIAGRAMS. SOLAR HIGH LIMIT CONTROL 13
14 TYPICAL SCHEMATIC WIRING DIAGRAMS order to function correctly. 14 VARIANT DUAL THERMOSTAT WIRING WIRING DIAGRAM 2 PORT ZONE VALVE (S-PLAN) DUAL STAT 2 PORT (DHW) 2 PORT (HTG) C 2 C 2 1 Br G Bl O G Y Br G BI O G Y WIRING CENTRE L N 5A SUPPLY PUMP L N L N E ROOM STAT PROGRAMMER BOILER
15 TYPICAL SCHEMATIC WIRING DIAGRAMS VARIANT DUAL THERMOSTAT WIRING WIRING DIAGRAM 3 PORT MID POSITION (Y-PLAN) + 2 PORT VALVE DUAL STAT 2 PORT (DHW) 3 PORT (HTG) C 2 C 2 1 Br G Bl O G Y W G BI O G Y WIRING CENTRE L N 5A SUPPLY PUMP N L L N E ROOM STAT PROGRAMMER BOILER 15
16 TYPICAL SCHEMATIC WIRING DIAGRAMS. FOR PRE-PLUMBED CYLINDER Connect power supply as per instruction manual. TP9000 terminals 5 & 6 can be used for remote sensor connection. 16 Connect power supply as per instruction manual. TP9000 terminals 5 & 6 can be used for remote sensor connection.
17 TYPICAL SCHEMATIC WIRING DIAGRAMS. FOR PRE-PLUMBED CYLINDER TP5000 E N L TP9000 E N L Green Plug W Y G/Y B1 G/Y Br Pump L N E SLB LP Boilder with over run BL BR GR OR Red Plug - Heating 1 BL BR GR OR Yellow Plug - Heating 2 B1 Br Gr Or Blue Plug - Water Wiring Diagram for Twin Zone Heating and Hot Water TP TP5000 to system using boilder to control pump Instruction for connection to a boiler with pump over run facility such as Ideal Logic Heat 1. Disconnect brown pre-wire pump flex from position Reconnect brown pre-wire pump flex to position Connect 5 core cable between boiler and wiring control centre to following positions WIRING CENTRE BOILER TERMINAL 1 PERMANENT LIVE L TERMINAL 3 PERMANENT NEUTRAL N TERMINAL 5 PERMANENT EARTH E TERMINAL 10 SWITCHED LIVE TO BOILER SL B TERMINAL 12 SWITCH LIVE TO PUMP L P 17
18 PRE-PLUMBED CYLINDER INSTALLATION CONNECTING TO THE CYLINDER BALANCED COLD CONNECTION balanced connection on the inlet set. CONNECTIONS FOR INDIRECT UNITS may be Gas, Electric or Oil but must be under effective thermostatic control. Uncontrolled heat sources such as some AGA s, back CONNECTIONS FOR SOLAR COILS SECONDARY CIRCULATION IMMERSION HEATERS 2 ELECTRICAL CONNECTIONS 17. COMMISSIONING 18
19 INDIRECT PRE-PLUMBED G J I H G F E D C B A CODE A B C D E F G H I J TI120P N/F TI150P N/F TI180P N/F TI210P TI250P TI300P SOLAR INDIRECT PRE-PLUMBED J I H F E G D C B A CODE A B C D E F G H I J TT180P N/F TT210P TT250P TT300P All Dimensions are in mm and are of the cased unit. 19
20 COMMISSIONING FLUSHING & FILLING DIRECT UNITS INDIRECT UNITS STORAGE TEMPERATURE can be found on the internet using the following internet site 20 GENERAL DRAINING ANNUAL MAINTENANCE service. HOT! 2
21 FAULT FINDING SPARE PARTS USER INSTRUCTIONS AND ACTION IS NEEDED. If this water is hot, turn the boiler and / or the immersion heater off. Do not turn off the water until the discharge runs cool. The DRAINING further details. 21
22 GUARANTEE TERMS AND CONDITIONS hereafter the term 22 commissioning. TM log book and service agreement / invoice. and all relevant Codes of Practice and Regulations in force at the time of installation. TM maintenance section of the installation manual.
23 or accordance with these conditions. Tadman Street WF1 5QU
24 GUARANTEE REGISTRATION CARD Home Owner Name Home Address Post code Make of product Model/size Serial Number Installers Contact details (can be found in benchmark log book) Date of installation can be found in benchmark log book) Signature of homeowner Or Signature of developer (If new build) Date Date
25 TECHNICAL SPECIFICATIONS PRESSURE SPECIFICATIONS Maximum Inlet Water Pressure Operating Pressure Expansion Valve Opening Pressure Expansion Vessel Charge Pressure Maximum Operating Pressure Opening Pressure of T & P Valve Opening Temperature of T & P Valve Maximum Pressure on Primary Circuit (Indirect & Solar Coil) 12 Bar 3.0 Bar 6.0 Bar 3.0 Bar 7.0 Bar 7.0 Bar 90 o C 3.5 Bar DIRECT IMMERSION ELEMENT SPECIFICATIONS Element Rating Thread Type Fuse Requirement Control Thermostat for Element - Temperature Range High Limit Thermostat for Element - Temperature Set Point 3kW 240 V 1 3/4 BSP 13A via Double Pole Switch 45 o C - 65 o C 85 o C INDIRECT IMMERSION ELEMENT SPECIFICATIONS Element Rating Thread Type Fuse Requirement Control Thermostat for Element - Temperature Range High Limit Thermostat for Element - Temperature Set Point 3kW 240 V 1 3/4 BSP 13A via Double Pole Switch 45 o C - 65 o C 75 o C 25
26 CYLINDER DETAILS & PERFORMANCE SPECIFICATION PRODUCT CODE WEIGHT EMPTY WEIGHT FULL CAPACITY HEAT-UP TIME 70% RE-HEAT TIME INDIRECT COIL SURFACE AREA INDIRECT COIL CAPACITY INDIRECT COIL kw RATING SOLAR COIL SURFACE AREA SOLAR COIL CAPACITY TRIBUNE DIRECT SLIMLINE TDS m - N/A N/A N/A N/A N/A 0.99 TDS m - N/A N/A N/A N/A N/A 1.05 TDS m - N/A N/A N/A N/A N/A 1.12 TDS m - N/A N/A N/A N/A N/A 1.29 TDS m - N/A N/A N/A N/A N/A 1.37 TDS m - N/A N/A N/A N/A N/A 1.64 TRIBUNE INDIRECT SLIMLINE TIS m 45s 8m 02s N/A N/A 0.99 TIS m 22s 15m 12s N/A N/A 1.05 TIS m 01s 16m 25s N/A N/A 1.12 TIS m 24s 19m 37s N/A N/A 1.29 TIS m 14s 23m 05s N/A N/A 1.37 TIS m 36s 27m 40s N/A N/A 1.64 TRIBUNE DIRECT TD m - N/A N/A N/A N/A N/A 0.91 TD m - N/A N/A N/A N/A N/A 1.05 TD m - N/A N/A N/A N/A N/A 1.23 TD m - N/A N/A N/A N/A N/A 1.32 TD m - N/A N/A N/A N/A N/A 1.58 TD m - N/A N/A N/A N/A N/A 1.84 TD m - N/A N/A N/A N/A N/A 2.10 TRIBUNE INDIRECT TI m 25s 14m 18s N/A N/A 0.91 TI m 47s 18m 00s N/A N/A 1.05 TI m 36s 20m 35s N/A N/A 1.23 TI m 58s 22m 47s N/A N/A 1.32 TI m 05s 26m 16s N/A N/A 1.58 TI m 18s 28m 20s N/A N/A 1.84 TI m 01s 32m 52s N/A N/A 2.10 TRIBUNE ECOCYL DIRECT TDS60ECO m - N/A N/A N/A N/A N/A 0.86 TDS90ECO m - N/A N/A N/A N/A N/A 0.89 TDS120ECO m - N/A N/A N/A N/A N/A 0.96 TDS150ECO m - N/A N/A N/A N/A N/A 1.06 TDS180ECO m - N/A N/A N/A N/A N/A 1.19 TDS210ECO m - N/A N/A N/A N/A N/A
27 CYLINDER DETAILS & PERFORMANCE SPECIFICATION PRODUCT CODE WEIGHT EMPTY WEIGHT FULL CAPACITY HEAT-UP TIME 70% RE-HEAT TIME INDIRECT COIL SURFACE AREA INDIRECT COIL CAPACITY INDIRECT COIL kw RATING SOLAR COIL SURFACE AREA SOLAR COIL CAPACITY TRIBUNE ECOCYL INDIRECT TIS60ECO m 45s 8m 02s N/A N/A 0.86 TIS90ECO m 22s 15m 12s N/A N/A 0.89 TIS120ECO m 01s 16m 25s N/A N/A 0.96 TIS150ECO m 24s 19m 37s N/A N/A 1.06 TIS180ECO m 14s 23m 05s N/A N/A 1.19 TIS210ECO m 36s 27m 40s N/A N/A 1.36 TRIBUNE SOLAR DIRECT TSS m 05s 22m 16s N/A N/A N/A TSS m 30s 23m 34s N/A N/A N/A TSS m 05s 26m 33s N/A N/A N/A TSS m 18s 28m 20s N/A N/A N/A TSS m 01s 32m 52s N/A N/A N/A TRIBUNE SOLAR INDIRECT TT m 50s 11m 44s TT m 15s 17m 02s TT m 31s 15m 50s TT m 42s 22m 42s TT m 04s 21m 30s TRIBUNE INDIRECT PRE-PLUMBED TI120P m 47s 18m 00s N/A N/A 1.05 TI150P m 05s 22m 16s N/A N/A 1.23 TI180P m 58s 22m 47s N/A N/A 1.32 TI210P m 30s 26m 16s N/A N/A 1.58 TI250P m 08s 30m 06s N/A N/A 1.84 TI300P m 40s 36m 12s N/A N/A 2.10 TRIBUNE SOLAR INDIRECT PRE-PLUMBED TT180P m 15s 17m 02s TT210P m 31s 15m 50s TT250P m 42s 22m 42s TT300P m 04s 21m 30s
28 28
29 MAINS PRESSURE HOT WATER STORAGE SYSTEM COMMISSIONING CHECKLIST This Commissioning Checklist is to be completed in full by the competent person who commissioned the storage system as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference. Failure to install and commission this equipment to the manufacturer s instructions may invalidate the warranty but does not affect statutory rights. Customer Name Address Cylinder Make and Model Cylinder Serial Number Commissioned by (print name) Company Name Company Address Telephone Number Registered Operative ID Number Telephone Number Commissioning Date To be completed by the customer on receipt of a Building Regulations Compliance Certificate* : Building Regulations Notification Number (if applicable) ALL SYSTEMS PRIMARY SETTINGS (indirect heating only) Is the primary circuit a sealed or open vented system? Sealed Open What is the maximum primary flow temperature? C ALL SYSTEMS What is the incoming static cold water pressure at the inlet to the system? bar Has a strainer been cleaned of installation debris (if fitted)? Yes No Is the installation in a hard water area (above 200ppm)? Yes No If yes, has a water scale reducer been fitted? Yes No What type of scale reducer has been fitted? What is the hot water thermostat set temperature? C What is the maximum hot water flow rate at set thermostat temperature (measured at high flow outlet)? l/min Time and temperature controls have been fitted in compliance with Part L of the Building Regulations? Yes Type of control system (if applicable) Y Plan S Plan Other Is the cylinder solar (or other renewable) compatible? Yes No What is the hot water temperature at the nearest outlet? C All appropriate pipes have been insulated up to 1 metre or the point where they become concealed Yes UNVENTED SYSTEMS ONLY Where is the pressure reducing valve situated (if fitted)? What is the pressure reducing valve setting? Has a combined temperature and pressure relief valve and expansion valve been fitted and discharge tested? Yes No The tundish and discharge pipework have been connected and terminated to Part G of the Building Regulations Yes Are all energy sources fitted with a cut out device? Yes No Has the expansion vessel or internal air space been checked? Yes No bar THERMAL STORES ONLY What store temperature is achievable? C What is the maximum hot water temperature? C ALL INSTALLATIONS The hot water system complies with the appropriate Building Regulations The system has been installed and commissioned in accordance with the manufacturer s instructions The system controls have been demonstrated to and understood by the customer The manufacturer s literature, including Benchmark Checklist and Service Record, has been explained and left with the customer Yes Yes Yes Yes Commissioning Engineer s Signature Customer s Signature (To confirm satisfactory demonstration and receipt of manufacturer s literature) * All installations in England and Wales must be notified to Local Authority Building Control (LABC) either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer. Heating and Hotwater Industry Council (HHIC)
30 SERVICE RECORD It is recommended that your hot water system is serviced regularly and that the appropriate Service Record is completed. Service Provider Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer s instructions. SERVICE 1 Date Engineer Name Company Name Telephone Number Comments SERVICE 2 Date Engineer Name Company Name Telephone Number Comments Signature Signature SERVICE 3 Date Engineer Name Company Name Telephone Number Comments SERVICE 4 Date Engineer Name Company Name Telephone Number Comments Signature Signature SERVICE 5 Date Engineer Name Company Name Telephone Number Comments SERVICE 6 Date Engineer Name Company Name Telephone Number Comments Signature Signature SERVICE 7 Date Engineer Name Company Name Telephone Number Comments SERVICE 8 Date Engineer Name Company Name Telephone Number Comments Signature Signature SERVICE 9 Date Engineer Name Company Name Telephone Number Comments SERVICE 10 Date Engineer Name Company Name Telephone Number Comments Signature Signature
31 NOTES 31
32 TRIBUNE HE SUPPLY OF QUALITY HOT WATER SYSTEMS Materials Coil - 22mm Diameter Stainless Steel Bosses - Stainless Steel Insulation The foam is CFC-Free and HCFC-Free. Potential of 1.1 Casework Anode Control Settings Immersion Heater Combined Thermostat and Safety Cutout Immersion Heater All sites are licensed to British Standards Quality Assurance future reference. the Benchmark Code of Practice which is available from the Heating and Hotwater Industry Council Range Cylinders Tadman Street, Wakefield WF1 5QU
WORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE
WORCESTER GREENSTORE Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE WORCESTER GREENSTORE 180 CYLINDER SOLAR COMPATIBLE WORCESTER GREENSTORE 280
More informationADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS
ISSUE JAN. 009 INSTALLATION AND USER GUIDE ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. STAINLESS STEEL UNVENTED
More informationSTAINLESS. Tornado & Tempest Stainless PRODUCTS. Installation Guide
STAINLESS PRODUCTS Tornado & Tempest Stainless Installation Guide MAINS PRESSURE DOMESTIC HOT WATER APPLIANCE STORAGE CAPACITY IN LITRES 90 125 150 170 200 250 300 WEIGHT WHEN FULL IN KGS 125 165 195 220
More informationMEGAFLO Eco. Technical data FOR THE ULTIMATE IN HOT WATER PERFORMANCE AND COMFORT
Technical data Technical data COMPONENTS THE FOLLOWING COMPONENTS ARE SUPPLIED AS STANDARD WITH MEGAFLO Eco FACTORY FITTED IMMERSION HEATER(S) AND THERMAL CONTROLS. INDIRECT MODELS: LONG-LIFE SUPERLOY
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationSystem Pressure Manager Standard & System Pressure Manager Plus
System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,
More informationTwin & Triple Control Concealed Thermostatic Shower Valve
Twin & Triple Control Concealed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS: 1. Introduction & Safety 1 2. Dimensions
More informationECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION
ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Models: DS 126 Single Pump / Single System DT 126 Twin Pump / Single System DS 160
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Micro-S / Micro-S Digital Wall Hung Unit Please fulfil all listed requirements prior to and during
More informationBar valve with fixed shower head Installation guide
Midas Plus Mono Bar valve with fixed shower head Installation guide Midas Plus Mono Midas Plus Mono Components Literature not shown Important information Introduction The Midas Plus Mono product is an
More informationInstallation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels
OM003 Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels The operating and maintenance instructions contained within this package are for standard storage vessels
More informationOWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01
DUAL CONTROL THERMOSTATIC SHOWER VALVE Shower Control Handles and Concealing Plate may differ depending on choice of Model OWNER S GUIDE ISSUE 01 These instructions cover all exposed or concealed versions
More informationInstallation and commissioning instructions 255 series and 256 series
Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...
More informationVIESMANN. Service instructions VITOSOL 200-T, 300-T. for contractors. Vitosol 200-T, 300-T. For applicability, see the last page
Service instructions for contractors VIESMANN Vitosol 200-T, 300-T For applicability, see the last page VITOSOL 200-T, 300-T 12/2008 Please keep safe. Safety instructions Safety instructions Please follow
More informationVIESMANN. Service instructions VITOSOL-F. for contractors. Vitosol-F. For applicability, see the last page GB 3/2009 Please keep safe.
Service instructions for contractors VIESMANN Vitosol-F For applicability, see the last page VITOSOL-F 3/2009 Please keep safe. Safety instructions Safety instructions Please follow these safety instructions
More informationUNVENTED HOT WATER SYSTEMS HAVE BECOME EXTREMELY POPULAR FOR BUILDING APPLICATIONS. WITH ALL THE MANDATORY
Unvented Packages Contents UNVENTED HOT WATER SYSTEMS 1 SYSTEM SCHEMATICS 2 PACKAGED EQUIPMENT 3 UNVENTED PACKAGES 4 DESIGNING UNVENTED SYSTEMS 5-7 CONVERSION FACTORS 8 EXPANSION VESSEL SELECTION TABLES
More informationLatvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.
Product Specification ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.0 bar Latvin Luxury Shower Panel ~ Fixing Centres 150mm +/- 10mm ~ Outlet size 1/2" Bottom Outlet Always maintain a
More informationPart 3.0. Storage Tanks
Part 3.0 Storage Tanks Title Section SV Series 3.1 GXC Series 3.2 LEX Series 3.3 EX Series 3.4 EHX Series 3.5 SHX Series 3.6 HEV Series 3.7 TC Series 3.8 05/07 SV Storage Tank 3.1 This information expands
More informationInstallation, Operation & Maintenance Instructions
Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information Read this manual carefully
More informationSelf-help Temperature Adjustment
Self-help Temperature Adjustment The Shower Valve temperature is pre-set to 42 C, but on certain installations the temperature may need to be adjusted. Note: The hot water supply must be above 60 C. Turn
More informationJET Mini Mechanical Pressurisation Equipment
JET Mini Mechanical Pressurisation Equipment Mini Models (130HL, 230HL) Operation & Maintenance Manual Rev 2.2 We reserve the right to change designs and technical specifications of our products. Rev 2.2
More informationInstallation, commissioning and servicing instructions
www.reece.com.au Tempering valve 38550.08 5213 series Installation, commissioning and servicing instructions The tempering valve is used to regulate the set temperature of mixed hot and cold water even
More informationInstallation, Operation and Maintenance Instructions Buffer Vessel OM006
Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk
More informationElectronic Single and Twin Pump System Pressure Managers
Electronic Single and Twin Pump System Pressure Managers Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING, OPERATING
More informationFlamco Flamco-Fill STA Flamco-Fill STM
STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744
More informationTempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series
www.reece.com.au 28255.01 Tempering valve for solar and instantaneous applications 2522HP series Installation, commissioning and servicing instructions The tempering valve is used to regulate the set temperature
More information11. Spare Parts. applications since applications since
2 8 2 6 20 2 8 0 5 6 8 9 2 2 25 7 8 9 5 0 2 2 7 . Spare Parts * C0 C02 C06 C0 C7 C C0 C5 C58 Article No. Description B-26 B-2009 Steam generation Steam cylinder CY DN20 compl. with electrodes and hand
More informationChesil - Electronic Pressurisation Unit
Chesil - Electronic Pressurisation Unit Equipment For Commercial/Light Industrial Central Heating Installations. Installation, Commissioning and Servicing Instructions IMPORTANT NOTE THESE INSTRUCTIONS
More information553 Series.
38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual
More informationBlowdown vessels Meeting the requirements of HSE PM60
Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels A complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove
More informationIn Vessel Composter Installation & Commissioning Manual
In Vessel Composter Installation & Commissioning Manual Contents Customer responsibilities Transportation Lifting Delivery Pre-installation requirements Installation Drainage Ventilation Levelling Unpacking
More informationOxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.
Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists
More informationInstallation, commissioning and servicing instructions
48323 www.caleffi.com Pre-adjustable pressure reducing valve with self-contained cartridge Copyright 2015 Caleffi 5350..H AUS series Installation, commissioning and servicing instructions Function Pressure
More informationCopper vs Stainless Steel. Test Results Show Impact on Performance and Costs
Copper vs Test Results Show Impact on Performance and Costs Table of Contents Introduction... 2 Test Information... 2 Cylinder Information... 3 Theory... 4 Heat-Up Test... 5 Apparatus... 5 Procedure...
More informationDN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2
Size : Ends: Min Temperature : Max Temperature : DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2 Materials : Bronze body
More informationSEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER
SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER CONTENTS 1. INTRODUCTION & SAFETY 1 2. DIMENSIONS 2 3. TECHNICAL DATA 3 4. OPERATION 4 5. COMPONENTS 5 6. SITE INSTALLATION
More informationDeluge Optimo Shower valve and kit 10032CP
Deluge Optimo Shower valve and kit 10032CP Installation, Operation and Maintenance Please leave these instructions with the user Intatec Limited Airfield Industrial Estate, Hixon, Staffordshire, ST18 0PF
More informationApproved Installation Method (AIM)
AIM-08-01 Issue 2 (DRAFT) 2015 Water Undertakers Approved Installation Method (AIM) Type BA Device Verifiable Backflow Preventer with Reduced Pressure Zone (RPZ Valve) Requirements for installation, commissioning
More informationInstallation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel
OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels
More information14. Exploded View. Page 68
14. Exploded View Page 68 15. View of housing Page 69 11. Spare Parts HY05 HY13 55 E-2124010 Keys for safety, set=2pc. 54 E-2124012 Safety lock incl. 2 keys 1 B-3204031 1 B-2204101 1 B-2204111 1 2 B-2204105
More informationINSTALLATION INSTRUCTIONS
Part No. IS275 Rev A- 09584-09584 TM HeatGuard INSTALLATION INSTRUCTIONS Certified Product Australian Standard AS4032.2 Lic. No. 1593 SAI-Global CONTENTS Choosing the correct model......... 3 How to install
More informationModuSat TP Twin Plate Satellite Heating Unit
ModuSat TP Twin Plate Satellite Heating Unit Installation, Commissioning and Servicing Instructions Evinox Ltd T. +44 (0)1372 722277 E. technical@evinox.co.uk W. www.evinox.co.uk 2551390A Contents 1 GENERAL
More informationThese instructions are to be left with the user
MIRA GEM 88 SHOWER CONTROL Installation & User Guide These instructions are to be left with the user CONTENTS Introduction... 3 Important Safety Information... 4 Pack Contents Checklist... 5 Dimensions...
More informationSMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings
SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings 38 READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. LEAVE THIS BOOKLET WITH THE END USER FOR FUTURE REFERENCE
More informationInstallation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger
OM008 Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger The operating and maintenance instructions contained within this package are for Pacific water/water
More informationInstallation and User Guide
INSTANT I3VS MANUAL ELECTRIC HANDWASH Installation and User Guide IMPORTANT: This booklet should be left with the user after installation and demonstration. THIS APPLIANCE CAN BE USED BY CHILDREN AGED
More informationScald Protection Three-Way Thermostatic Mixing Valve
CALEFFI www.caleffi.com 383.04 Scald Protection Three-Way Thermostatic Mixing Valve Copyright 00 Caleffi 3 Series Installation, commissioning and servicing instructions Function Scald Protection Three-Way
More informationAPRIL 2017 Level 3 Advanced Technical Diploma in Plumbing (450) Level 3 Plumbing Theory Exam
*82025350417* 8202-535 APRIL 2017 Level 3 Advanced Technical Diploma in Plumbing (450) Level 3 Plumbing Theory Exam If provided, stick your candidate barcode label here. Candidate name (first, last) First
More informationAIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115
AIR COMPRESSOR MODEL NO: CHAMP 3 PART NO: 2225222 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Air Compressor. Please read this manual fully before use
More informationProduct Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment
Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces
More informationTEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL
Product Support Guarantee This product is guaranteed against faulty materials and workmanship for 12 months from date of purchase. For the guarantee to be valid, the unit must be installed by a competent
More informationThermocirc Installation and Maintenance Instructions
1570072/2 IM-P157-36 ST Issue 2 Thermocirc Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation 6 Maintenance
More informationInstruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013
Instruction Sheet 102-492 5123-WH-N Lead Free (.25% Pb) Mixing Valve SUPERSEDES: New EFFECTIVE: August 1, 2013 Plant I.D. 001-4206 WARNING: Water temperatures above 120 F can cause serious injury. Mixing
More informationMaterials : Brass body dezincification-resistant up to DN1 1/4
Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Male, Male BSP + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass body dezincification-resistant up to DN1 1/4 Controlable With male
More informationTHESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER
SHOWER CONTROL Installation Operation &B Maintenance Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER Contents Section Page 1... Introduction... 3 2... Important Safety Information... 4 3... Pack
More informationThanks for choosing EJAI SOLAR product
SPLIIT SOLAR WATER HEATER (( YYJ--S01 SERIIES )) IINSTALLATIION MANUAL www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 1 Thanks for choosing EJAI SOLAR product Content 1. Important Information....2
More informationENERGY BLADE 3K4. Energy Blade Installation Instructions
ENERGY BLADE 3K4 Energy Blade Installation Instructions 1 Contents General information 2 Scope of these instructions 2 Product information 2 Designated use 3 Warranty 3 Safety instructions 4 Assembly and
More informationServicePlus S21R & S27R Series 2 Installation Instructions
ServicePlus S21R & S27R Series 2 Installation Instructions Horstmann Controls ServicePlus two channel service interval programmers have been developed to facilitate compliance with the Gas Safety (Installation
More informationREGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE
No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2015 LICENSED PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2015. All rights reserved. No part of this publication may be reproduced by
More informationWATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL
Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationInstallation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve
Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve TMV3 / TMV2 Combined Valve C85079 C85081 C85080 C85082 It is important that these guidance notes are read and fully understood
More informationLED 14W POLO BULKHEAD WITH MICROWAVE SENSOR
INTRODUCTION The LED 14W POLO Bulkhead is a modern lowcost and energy efficient fitting ideal for domestic and utility applications. SPECIFICATION LED 1150lm IP54 220-240V IK09 4000K 50/ 60Hz >82 Ra 14W
More informationSelf-managing shallow geothermal well systems
GUIDELINES PRACTICE GOOD Self-managing shallow geothermal well systems FOR PCBUs WITH GEOTHERMALLY HEATED POOLS OR PLANT March 2018 These guidelines are for PCBUs (including local authorities) who have
More informationMainsboost Installation, Operation & Maintenance Instructions
mainsboost Mainsboost Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information
More informationSAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER
SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established
More informationInstallation, commissioning and servicing instructions
38512.08 Tempering valve www.caleffi.com 5213 series Copyright 2018 Caleffi Installation, commissioning and servicing instructions The tempering valve is used to regulate the set temperature of mixed hot
More informationEnerVal. Technical data litre storage capacity. Buffer storage vessels
EnerVal Buffer storage vessels Technical data 200-10000 litre storage capacity Contents Title Page number EnerVal (200-2000) Description 3 Part No. 4 Technical data 6 Dimensions 7 EnerVal G (1000-10000)
More informationmatrix installation guide
matrix installation guide Matrix pressurisation units These installation, commissioning and servicing instructions are intend for use with the matrix compact and standard pressurisation units. efore commencing
More informationAE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions
0176050/3 IM-P017-11 ST Issue 3 AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4
More informationScald Protection 3-Way Thermostatic Mixing Valve
383.06 www.caleffi.com Scald Protection 3-Way Thermostatic Mixing Valve Copyright 06 Caleffi 3 Series Installation, commissioning and servicing instructions Function Scald Protection Three-Way Thermostatic
More informationDECLARATION OF INCORPORATION
AESSEAL (MCK) Ltd. Systems Division 139a Hillsborough Old Road Lisburn Northern Ireland BT27 5QE Tel +44 (0) 2892 669966 Fax +44 (0) 2892 669977 When selecting and installing suitable Barrier Fluid System
More informationRemeha Quinta Cascade guide
Technical information Remeha Quinta Cascade guide Cascade guide Cascade systems 2 Remeha Quinta Cascade guide TABLE OF CONTENTS FOREWORD 4 1 GENERAL DESCRIPTION OF CASCADE SYSTEMS 4 1.1 Optimum number
More informationAUTOMATIC GAS MANIFOLDS
AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com
More informationHill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide
Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide Secondary Coolant System Start-Up Procedures June 2006 Produced by the Hill PHOENIX Learning Center DISCLAIMER This
More informationTHESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER
SHOWER CONTROL Installation Operation &B Maintenance Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1 Contents Section Page 1... Important Safety Information... 4 2... Introduction...5 3... Pack
More informationDS MZ, MZF, MJF THREE-PORT SEAT VALVES
DS 4.610 11/99, F, THREE-PORT SEAT VALVES Specification No. 626-3-XXX These seat valves are of 'globe' construction with a linear moving spindle and a modified parabolic characterised plug operating against
More informationEasy-Pro Installation & Operations Guide
Easy-Pro Installation & Operations Guide Installation & Maintenance Guide Operation The EASY-PRO range of Expansion Vessels is specifically designed for Unvented Potable Systems to deal with increased
More informationSealed Systems Altecnic Ltd - Caleffi group. Sealed Systems. Heating vessel sizing guide
1.25 Sealed Systems Sealed Systems Sealed primary central heating systems are the most commonly used form of heating system throughout Europe and the rest of the developed world. Sealed central heating
More informationMainsboost Charger Installation, Operation & Maintenance Instructions
mainsboost Mainsboost Charger Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information
More informationPRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09
PRESSURE TEST PUMP Model No: PTP00 Part No: 06020 OPERATING & MAINTENANCE INSTRUCTIONS GC0/09 INTRODUCTION Thank you for purchasing this CLARKE Pressure Testing Pump. Before attempting to use the product,
More informationInformation Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100
Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet
More informationAutoChanger Installation & User Guide Issue 2
1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide
More informationPumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out
PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL
More informationInstallation, commissioning and servicing instructions
488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet
More information24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:
24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 1499490 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0918 - ISS 2 INTRODUCTION Before attempting to use this product, please read this
More informationPROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION
PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION Provengas Labsafe PGLS001 Provengas Cooksafe PGCS003 2 Provengas Labsafe has been designed as a gas pressure proving system for use in schools and
More informationbathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents
bathrooms.com Concentric Thermostatic Shower Mixers Contents Page 3 - General Information & Safety Page 4 - Installation Page 5 - Concentric Valve Set-up Page 6 - Exposed fitting of Concentric Mixer Valves
More informationLEGIONELLA MANAGEMENT PROCEDURE
LEGIONELLA MANAGEMENT PROCEDURE This procedure sets out the aims and objectives of the school and outlines responsibilities for managing the risk of exposure to legionella. General Statement of Intent
More informationHORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003
PO Box 7, Rankine Street Johnstone, Renfrewshire Scotland. PA5 8BD Tel: 01505 321 455 Fax: 01505 336 287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003
More informationVentam 85 Installation & Commissioning Instructions
Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Ventam 85 Installation & Commissioning Instructions 1 General The Ventam
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making
More informationHEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)
SECTION Bypass Oil Sampling Station (B.O.S.S 1000) GENERAL.......................... SAFETY........................... Hazards............................... Personal Protective Equipment........... PRODUCT
More informationInstallation Instructions and User Guide
Installation Instructions and User Guide 15mm & 22mm In-Line Thermostatic Mixing Valve-TMV2 Model P404 It is important that these guidance notes are read and fully understood prior to product installation
More informationURINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR
URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR Installation & Maintenance Instructions EMF303M I00013_Aug 15 Call 1300 369 273 www.enware.com Enware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229
More information24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13
24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: 2244030 OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product,
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationInstallation Operation Maintenance
682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description
More informationHydraulic Valve Installation Guide
Hydraulic Valve Installation Guide 1. Introduction The Hydraulic Valve is an automatic urinal flush control valve. The valve uses a unique and simple mechanism which prevents water waste by ensuring that
More information