Newsletter nº 2 May 2015
|
|
- Roberta Roberts
- 5 years ago
- Views:
Transcription
1 Newsletter nº 2 May 2015 Measurement system setup Ajdovščina Fig. 1: The measurement system in Ajdovščina 1
2 Wind Risk project is being implemented with the contribution of the Civil Protection Financial Instrument of the European Union. Within the Wind Risk prevention project we planned to set up a system to measure wind characteristics in different regions and get information about different types of wind. The measurements of wind speed and direction will be shown on an internet page with live stream that will display the information in real time. The readings will also be used as an alarm system for local civil protection service and will alert them immediately after average wind speed or wind gusts exceed specific limits. To gain this knowledge we have set up the first wind measurement system in Ajdovščina. The area around the city of Ajdovščina is exposed to high winds and wind gusts. The most common phenomena in the area is so called Burja or Bora. Bora is observed in the countries from Italy to Turkey to Russia. The root of the word is found in the Greek word borea, which means north. Bora is a cold wind coming from the north. The wind blows with high average wind speeds and additional violent bursts of wind gusts. In the area the average presence of bora is 42 days per year. The highest wind gust speeds exceed 200 km/h. The high wind causes damage to trees, buildings, affects traffic and people. Location The first measurement system has been set up in the city of Ajdovščina on the roof of the stadium of their football team next to the Ajdovščina sport plane airport. The measurement system is orientated towards the north from where the bora winds generate from the neighboring hills. The roof is approximately 12 meters high and slender on the side of the wind direction, therefore the wind is blows with minimal turbulence and measurements should be realistic. Fig. 2: The location of the first measurement system in Ajdovščina 2
3 Fig. 3: The map of the first measurement system in Ajdovščina 45 Fig. 4: The plywood orientation from the top The orientation in not important for the sole wind measurement, but more for the plywood board beneeth the anemometer where actual forces will be measured. The purpose of force measurements is to observe the relationship between wind speed and wind direction and the forces it generates. 3
4 Allthough this might seem trivial, it isn't. Especialy when we talk about wind gusts, since they are very short and the actual forces are not the same as when compared to forces at steady wind. Anemometer The WindMaster Pro anemometer from GILL Instruments is on top of a stiff steel construction that is mounted on one of the roof beams. It is approximately two meters above the roof top. The WindMaster Pro is constructed from stainless steel and has a maximum operating wind speed of 65 m/s. With a fast maximum data output rate of 32Hz as standard, improved vertical (W) resolution and Speed of Sound accuracy and less distortion due to wind loading, this 3 axis anemometer is particularly suitable for precision wind measurement applications requiring 3 axis data. Anemometer records speed in three directions U, V and W. U is defined as towards the direction in line with the north spar as indicated in the diagram. V is defined as towards the direction of 90 anti clockwise from N / the Reference spar. W is defined as vertically up the mounting shaft. Temperature is also recorded. An example of the record is shown below. The M sign in the record stands for metric units. U V W Temperature Fig. 5: The plywood orientation from the side 4
5 Data acquisition The data from the anemometer is in digital form and is passed through an RS422 cable that is connected to a National Instrument RS422 to Ethernet Interface unit called ENET 485/2. The signal than goes over the Ethernet to the computer. The software used for recording and controlling the output format of the instrument is a program called Wind. Fig. 6: National Instrument RS422 Fig. 7: The window of the program called Wind 5
6 Live stream A live stream web page will be set up on a remote server in Split that will display the measurements in real time. An alarm system for local civil response units will be integrated in the design of the page that will send out an alert when the wind speed values become critical. Force measurements Further steps include a force measuring system that will used for scientific purposes to study the pressure forces due to wind. AST KAP S force sensors will be mounted behind a square meter plywood board, that will be screwed to the construction beneath the anemometer. The maximum force of the sensors is 2kN. Fig. 8: AST KAP S force sensor The sensors will be connected to the ethernet via a National Instruments Bridge module NI 9237 and a Data acquisition unit NI cdaq Fig. 9: A Bridge module NI 9237 (left) and a Data acquisition unit NI cdaq
Ultrasonic Fuel Level Sensor - UFLS
Ultrasonic Fuel Level Sensor If your business infrastructure relies on backup generators, the chances are you are also relying on fuel to power those. By using the AKCP Ultrasonic Fuel Level Sensor you
More informationScanFish Katria. Intelligent wide-sweep ROTV for magnetometer surveys
ScanFish Katria Intelligent wide-sweep ROTV for magnetometer surveys User-friendly control and monitoring software solution The ScanFish Katria comes with the ScanFish III Flight software, which is an
More informationAC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW
AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi
More informationAFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features
ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor
More informationOPERATIONAL USE OF A WIND PROFILER FOR AVIATION METEOROLOGY ABSTRACT
OPERATIONAL USE OF A WIND PROFILER FOR AVIATION METEOROLOGY Miguel Angel Pelacho, Darío Cano, Eugenio Ayensa Spanish Agency of Meteorology (AEMET) Parque del Buen Retiro, Apdo. 285, 28080-MADRID E-mail:
More informationConditions for occurrence of vortex shedding on a large cable stayed bridge. Full scale data from monitoring system
Conditions for occurrence of vortex shedding on a large cable stayed bridge. Full scale data from monitoring system O. Flamand 1, F. De Oliveira 1 and A. Stathopoulos-Vlamis, P. Papanikolas 2 1 Centre
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationHigh-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements
More informationRoyce Interface Level Analyzer and Sensors
Royce Interface Level Analyzer and Sensors Model 2511A Interface Level Analyzer The Model 2511A is capable of having the ultrasonic speed of sound signal from its transducers changed by the user in applications
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationA differerential pressure anemometer
A differerential pressure anemometer S. Kazadi, J. Lee, T.Lee, A. Bose June 6, 2015 Abstract There are a number of different applications where omnidirectional anemometers are needed rather than directional
More informationPressure Calibrators. Series PC..., PM...
Pressure Calibrators Series PC..., PM... SIKA-Precision Pressure Calibrators, Series PC..., PM... We help you, if you are under pressure! Pneumatic pressure calibrators PM 25 A, PM 25 D, PM 110 PIC pressure
More informationOPERATIONAL TEST OF SONIC WIND SENSORS AT KNMI
OPERATIONAL TEST OF SONIC WIND SENSORS AT KNMI Wiel M.F. Wauben 1 and Rob van Krimpen 2 1 R&D Information and Observation Technology, 2 Observation Systems Operations Royal Netherlands Meteorological Institute
More informationSorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply
Sensen DCS Series General Purpose Systems Power Supply High power density / low ripple and noise High programming resolution with Ethernet interface Constant voltage and current mode Remote sensing Isolated
More informationP499 Heavy Duty Pressure Transducer
P499 Heavy Duty Pressure Transducer Product Bulletin Code No. LIT-??? E Issued 11 2006 The P499 Series is a new global Pressure Transducer with an excellent price performance ratio. The P499 exceeds the
More informationLevel transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids
Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids No contact with the product Compact design with polycarbonate housing (electronics and display).
More informationINSTRUCTION MANUAL. January 23, 2003, Revision 0
INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationSCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties
Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationSpecifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)
Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS) A. Scope of Work The work covered by these specifications consists of furnishing all materials, labor,
More informationFull scale measurements and simulations of the wind speed in the close proximity of the building skin
Full scale measurements and simulations of the wind speed in the close proximity of the building skin Radoslav Ponechal 1,* and Peter Juras 1 1 University of Zilina, Faculty of Civil Engineering, Department
More informationUltrasonic level transmitter and indicator
Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive
More informationDigital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN
Data Sheet: DFP.418.R4.EN www.ntt.dk Digital Pressure Gauge PRESSURE FORCE The DFP series digital gauges are made according to the more modern technologies in order to provide a high level of reliability,
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationVertical Wind Energy Engineering Design and Evaluation of a Twisted Savonius Wind Turbine
Design and Evaluation of a Twisted Savonius Wind Turbine Ian Duffett Jeff Perry Blaine Stockwood Jeremy Wiseman Outline Problem Definition Introduction Concept Selection Design Fabrication Testing Results
More informationQuick Installation Guide Doc nr.: C Date:
Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or
More informationDrag racing system HL190 User Manual and installation guide
Drag racing system HL190 User Manual and installation guide Version 10/2015 TAG Heuer Timing Page 1 / 14 1. Global This software controls the whole Drag racing installation HL190. Combined with the Chronelec
More informationHeat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.
Heat Engine Equipment: Capstone, 2 large glass beakers (one for ice water, the other for boiling water), temperature sensor, pressure sensor, rotary motion sensor, meter stick, calipers, set of weights,
More informationMASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS
MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass
More informationSpecifications for the CMI 2409 Magnetocardiograph
Specifications for the CMI 2409 Magnetocardiograph Revision date April 14, 2006 1 518-381-1000 (tel) The CMI-2409 system consists of a holder (A), a patient bed (B) and a workstation (not shown in the
More informationThe M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions
The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly
More informationHigh-speed pressure sensor Model CPT6140
Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications
More informationM. Mikkonen.
Wind study by using mobile sodar technology M. Mikkonen Oulu University of Applied Sciences, School of Engineering, Oulu, Finland t3mimi00@students.oamk.com Abstract In this paper is presented a concept
More informationFABRICATION OF VERTICAL AXIS WIND TURBINE WITH WIND REDUCER AND EXPERIMENTAL INVESTIGATIONS
87 CHAPTER-4 FABRICATION OF VERTICAL AXIS WIND TURBINE WITH WIND REDUCER AND EXPERIMENTAL INVESTIGATIONS 88 CHAPTER-4 FABRICATION OF VERTICAL AXIS WIND TURBINE WITH WIND REDUCER AND EXPERIMENTAL INVESTIGATIONS
More informationWind Flow Validation Summary
IBHS Research Center Validation of Wind Capabilities The Insurance Institute for Business & Home Safety (IBHS) Research Center full-scale test facility provides opportunities to simulate natural wind conditions
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationWindcube FCR measurements
Windcube FCR measurements Principles, performance and recommendations for use of the Flow Complexity Recognition (FCR) algorithm for the Windcube ground-based Lidar Summary: As with any remote sensor,
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationDeploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President
Lowell Instruments Application Note #TCMA Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President 1 Introduction The TCM-1 Tilt Current Meter (TCM)
More informationWhere are you right now? How fast are you moving? To answer these questions precisely, you
4.1 Position, Speed, and Velocity Where are you right now? How fast are you moving? To answer these questions precisely, you need to use the concepts of position, speed, and velocity. These ideas apply
More informationCourseware Sample F0
Electric Power / Controls Courseware Sample 85303-F0 A ELECTRIC POWER / CONTROLS COURSEWARE SAMPLE by the Staff of Lab-Volt Ltd. Copyright 2009 Lab-Volt Ltd. All rights reserved. No part of this publication
More informationThe following figure shows a 4-legged silo and the involved forces in presence of wind: F vw2 :
Technical Notes WIND LOAD ON SILOS The aim of this technical note is to make an introduction to the effect of the wind on a silo by identifying the forces that appear on weighing assemblies in addition
More informationLOW LAYER WIND SHEAR OVER DAKAR
LOW LAYER WIND SHEAR OVER DAKAR Dr Cheikh Sadibou SOW ASECNA Senior Meteorologist Abstract : Low layer wind shears are dangerous for planes. Their observation and study are one of the main fields where
More informationProgrammable Submersible Level Transmitters
Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationL 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions
L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6
More informationAir Bubbler Depth Gauge DG2200 Installation and Reference Manual
Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...
More informationPlasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling
SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic
More informationE. Agu, M. Kasperski Ruhr-University Bochum Department of Civil and Environmental Engineering Sciences
EACWE 5 Florence, Italy 19 th 23 rd July 29 Flying Sphere image Museo Ideale L. Da Vinci Chasing gust fronts - wind measurements at the airport Munich, Germany E. Agu, M. Kasperski Ruhr-University Bochum
More informationCOMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid
Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,
More informationElectronic gas volume corrector model DGVC-04
Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector
More informationThe Seventh International Colloquium on Bluff Body Aerodynamics and Applications (BBAA7) Shanghai, China; September 2-6, 2012 Wind tunnel measurements
The Seventh International Colloquium on Bluff Body Aerodynamics and Applications (BBAA7) Shanghai, China; September 2-6, 2012 Wind tunnel measurements of aeroelastic guyed mast models a, Tomasz Lipecki
More informationEEF. Fatigue Testing Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment
Engineering and Technical Teaching Equipment Fatigue Testing Unit EEF PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION ISO 9001: Quality Management (for Design, Manufacturing, Commercialization and After-sales
More informationREMOTE SENSING APPLICATION in WIND ENERGY
REMOTE SENSING APPLICATION in WIND ENERGY Siraj Ahmed Professor & Head Department of Mechanical Engineering Maulana Azad National Iinstitute of Technology Bhopal, India sirajahmed@manit.ac.in Contents
More informationLab 1c Isentropic Blow-down Process and Discharge Coefficient
058:080 Experimental Engineering Lab 1c Isentropic Blow-down Process and Discharge Coefficient OBJECTIVES - To study the transient discharge of a rigid pressurized tank; To determine the discharge coefficients
More informationViva TPS. TS11/15 Total Stations Check and Adjust Procedure. October Summary
Viva TPS October 2010 TS11/15 Total Stations Summary Leica builds total stations to the highest quality and calibrates each instrument before it leaves the Factory. After the instrument is shipped or used
More informationMeasurement and simulation of the flow field around a triangular lattice meteorological mast
Measurement and simulation of the flow field around a triangular lattice meteorological mast Matthew Stickland 1, Thomas Scanlon 1, Sylvie Fabre 1, Andrew Oldroyd 2 and Detlef Kindler 3 1. Department of
More informationBUYER S GUIDE AQUAlogger 530WTD
OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored
More information780S Ultra High Purity Series
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board
More informationAANDERAA. Measuring: Current Speed Current Direction Temperature
AANDERAA Doppler Current Meter A state-of-the-art Recording Current Meter designed for deep sea operation down to 6000 meters Measuring: Current Speed Current Direction Temperature Optional: Conductivity
More informationFLAMMABLE GAS SENSOR/TRANSMITTER
FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationSchedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT
S. No 1 Description Calorimeter The Unit should be designed for the accurate determination of the calorific value of liquid and solid hydrocarbons and other fuels. Specifications: A temperature-controlled
More informationBAROMETER PRESSURE STANDARD PRESSURE CONTROLLER
BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More information3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy
KROHNE 07/2005 7.02446.25.00 GR 3000 Series OPTIMASS Mass Flowmeter with single Z-shaped measuring tube Stainless Steel Hastelloy Status: 10/99 One tube no limits No limits with tube material No limits
More informationSite Summary. Wind Resource Summary. Wind Resource Assessment For King Cove Date Last Modified: 8/6/2013 By: Rich Stromberg & Holly Ganser
Site Summary Wind Resource Assessment For King Cove Date Last Modified: 8/6/2013 By: Rich Stromberg & Holly Ganser Station ID: 2857 Latitude: 55 7 45.8 N Longitude: 162 16 10.6 W Tower Type: 30 m NRG Tall
More informationDrift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer
Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer M. F. Vineyard, T. J. Carroll, and M. N. Lack Department of Physics University of Richmond, VA 23173 ABSTRACT The
More informationIn Vivo Scientific, LLC INSTRUCTION MANUAL
CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3
More informationPressure transmitter PASCAL Ci4
Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution
More informationDraw-wire system SZG165
Draw-wire system SZG165 www.wachendorff-automation.com Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and customer versions
More information5 Channel Calibrator
212 N. Woodwork Lane Palatine, IL 60067 800-223-3977 5 Channel Calibrator Part # 0724 User Manual Questions? Contact us at 800-223-3977 or online at http://www.cleanair.com/equipment/express/main.html
More informationTechnical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description
Smart-Trak Model 100 High Performance Digital Gas Mass Flow Meters and Controllers Features Measure & control gas mass flow rates up to 1000 slpm True digital performance provides high accuracy and great
More informationLEA_EN_PZL Dynamometric Scale. Instruments and Systems for Geotechnical and Structural Monitoring
LEA_EN_PZL8001001 Dynamometric Scale LEA_EN_PZL8001001 Dynamometric Scale Description _ The dynamometric scale is a precise, reliable and rugged instrument. The instrument was installed on different dams
More informationLX Compass module 3 Electronic compass device User manual
LX Compass module 3 Electronic compass device User manual LX navigation d.o.o., Tkalska 10 SLO 3000 Celje, tel: + 386 3 490 46 70, fax: + 386 3 490 46 71 info@lxnavigation.si, http://www.lxnavigation.com
More informationINSTRUMENT INSTRUMENTAL ERROR (of full scale) INSTRUMENTAL RESOLUTION. Tutorial simulation. Tutorial simulation
Lab 1 Standing Waves on a String Learning Goals: To distinguish between traveling and standing waves To recognize how the wavelength of a standing wave is measured To recognize the necessary conditions
More informationWindar Photonics Wind Sensor. Great at Control
Windar Photonics Wind Sensor Version 1.0 2012 Contents Imagine Being Able to Predict the Wind 5-6 Wind Sensors in a New Light 7-8 You Harvest the Wind Better from the Top 9-10 Result of a Bright Idea 11-12
More informationHigh Definition Laser Scanning (HDS) Underwater Acoustic Imaging and Profiling
High Definition Laser Scanning (HDS) Underwater Acoustic Imaging and Profiling Images at Depth: The Use of Acoustic Imaging on Large River Crossings A Case Study AGENDA Background of project Review of
More informationParametrable / Programmable Pressure Transmitter
Parametrable / Programmable Pressure Transmitter PTM/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available
More informationOwners Manual Release Date: Thursday, December 29, 2011
S MFD/LRL Generators Page 1 Ground Current Generator GCG By Tim Williams Owners Manual Release Date: Thursday, December 29, 2011 This document is subjected to change without any notice. Please check the
More informationFor Multi-Parameter Meters see mvx
Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid
More informationMECHANICAL BULKMETERS BM Series
PRO MEA 05 PRODUCTS - Measurement MECHANICAL BULKMETERS BM Series Positive displacement liquid measuring instruments Unequalled performance in measurement Free from installation effects Flow Rates of 25
More informationLow Profile Load Cells
Low Profile Load Cells World Leading Performance With Improved Linearity, Hysteresis, Creep & Thermal Performance Introducing Interface s Enhanced Low Profile Load Cell Interface Inc. pioneered the first
More informationEPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale
EPR-3000 High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale General Specifications PRECISE CONTROL UP TO 3000 PSI The Equilibar EPR-3000 dual valve pressure controller
More informationInstruction Manual. Pipe Friction Training Panel
Instruction Manual HL 102 Pipe Friction Training Panel 100 90 80 70 60 50 40 30 20 10 HL 102 Instruction Manual This manual must be kept by the unit. Before operating the unit: - Read this manual. - All
More informationLab 7 Rotational Equilibrium - Torques
Lab 7 Rotational Equilibrium - Torques Objective: < To test the hypothesis that a body in rotational equilibrium is subject to a net zero torque and to determine the typical tension force that the biceps
More informationFor Multi-Parameter Meters see mvx
VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid
More informationCoda cx1 Thermal Cycle Test Procedure
Coda cx1 Thermal Cycle Test Procedure CDL 1-TP07-0200:0209 MIT Ref. 85-01050.04 Revision 2.0 8 th June 2004 CDL 1-TP07-0200:0209 Contents 1 Introduction... 1 1.1 Activity Description... 1 2 Requirements...
More informationMEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet
Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97
More informationPrecision Liquid Settlement Array Manual
Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change
More informationWeatherStation Monitoring for Industrial marine Applications
WeatherStation Monitoring for Industrial marine Applications PB200 WeatherStation Instrument Applications: Industrial marine weather monitoring Features: True and Apparent Wind Speed and Direction Barometric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationFlow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25
VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationA WHITE PAPER. Subject: What Aspects Should Be Considered When Selecting A. Gas Bubbler System. Part I
A WHITE PAPER Subject: What Aspects Should Be Considered When Selecting A Gas Bubbler System Part I By: Bill Fletcher President and Chief Scientist at Design Analysis Associates, Inc. The WATERLOG Gas
More informationPressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller
w w w. m k s i n s t. c o m Pressure & Vacuum Measurement Solutions Series 370 Stabil-Ion Vacuum gauge and Controller Features & Benefits All-metal, rack-mount controller for Stabil-Ion and Convectron
More informationHASTAC High stability Altimeter SysTem for Air data Computers
HASTAC High stability Altimeter SysTem for Air data Computers André Larsen R&D Director Memscap Sensor Solution SIXTH FRAMEWORK PROGRAMME PRIORITY 4 Aeronautics and Space EC contract no. AST4-CT-2005-012334
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationINSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr
INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION
More information