1 DECATUR TOWNSHIP FIRE DEPARTMENT GENERAL ORDER TITLE: MANDATORY USE OF SCBA NUMBER: 9.01 EFFECTIVE: May 1, 2016 THIS ORDER SUPERSEDES ALL PREVIOUS GENERAL ORDERS, POLICIES, RULES, S.O.G S & S.O.P S UPDATED: FEBRUARY 15, 2017 This policy is for internal use only and does not enlarge an employee s civil liability in any way. The policy should not be construed as creating a higher duty of care, in an evidentiary sense, with respect to third party civil claims against employees. A violation of this policy, if proven, can only form the basis of a complaint by this department for non-judicial administrative action in accordance with the laws governing employee discipline. I. PURPOSE In many cases it is not practical or possible for firefighters or fire officers to judge the degree of danger involved in working in contaminated or oxygen deficient atmospheres. The Scott self-contained breathing apparatus is designed to provide the wearer with a supply of respirable air carried in the apparatus and requires no intake of air or oxygen from the environment in which the wearer is operating. This General Orders establishes a policy mandating the use of self-contained breathing apparatuses (SCBA) by all personnel working in or who may potentially work in smoke-filled or otherwise toxic environments while responding to an emergency. II. DEFINITIONS COMPANY MEMBERS: All privates, engineers, lieutenants, and captains who are assigned to fire and/or rescue companies. SCBA: Self-contained breathing apparatus. TOXIC ENVIRONMENT: For the purpose of this order shall mean any environment where fire exists or has existed causing toxic smoke, gases, and/or vapors or any environment where Carbon Monoxide is present above 35ppm. INVESTIGATOR: Member(s) assigned to Fire Investigation. HOT ZONE: An area that is considered to be dangerous. It generally entails special equipment to protect occupants, because there is a high risk of danger. Determined parameters by the IC. Page 1 of 4 General Order 9.01
2 III. POLICY A. Any firefighter who is working in or is about to enter a smoke filled or otherwise toxic environment while responding to an emergency situation shall don and activate the selfcontained breathing apparatus provided by the Decatur Township Fire Department. B. Company members responding to any building fire, structural fire or hazardous materials incident shall don the SCBA before leaving their apparatus. The SCBA must be activated just prior to entering any toxic environment or hot zone. C. Personnel working in a toxic environment shall wear SCBA and be on-air during all phases of the operation (fire control, overhaul, etc.). IV. PROCEDURE RESPONSIBILITIES OF THE COMPANY MEMBERS A. Company members shall be responsible for checking, inspecting and testing the SCBA assigned to their riding position to ensure the unit is operating properly. This shall include but not limited to: (H.U.D function, P.A.S.S function, 5500 psi cylinder). B. If it is not clear whether or not respiratory protection is required, all firefighters should assume that SCBAs should be worn and activated. C. All company members shall activate their SCBA before entering a building for fire operations or before entering any area that may require respiratory protection. D. Company members performing aerial operations, raising ladders, operating hand lines outside a fire building are required to don and activate the SCBA anytime they are working in or around a toxic environment, when directed by a superior officer, or in their judgment they feel that the atmosphere may be harmful to their health. (Example: While performing outside horizontal ventilation in smoke conditions) E. Company members performing roof ventilation are required to be on-air at all times while performing ventilation on any roof. F. The SCBA will be worn and activated by all personnel responding to a hazardous materials incident. The SCBA shall be worn by all personnel until the officer in command of the scene has evaluated the extent of the toxicity Page 2 of 4 General Order 9.01
3 problem and established a working perimeter, outside of which the SCBA will not be worn. G. The SCBA shall be worn and activated during overhaul or anytime while working in the hot zone. H. The Battalion Chief or Safety Officer will take readings before the all clear can be given. RESPONSIBILITIES OF THE OFFICER IN COMMAND OF AN EMERGENCY SCENE A. It shall be the responsibility of the Incident Commander of any emergency scene, through the company officers, to ensure that firefighters dispatched to the scene comply with this General Order. B. Chief Officers shall don respiratory protective equipment when it is necessary to enter a fire building or any area where a toxic environment may exist. C. If it is necessary to designate an area (i.e. a field, a city block, etc.) off limits to personnel not wearing an SCBA, then it shall be the responsibility of the Incident Commander to designate that area and ensure that compliance is achieved. D. If an area is designated off limits, personnel shall not enter that area without donning and activating an SCBA. E. It is the responsibility of all Company Officers and Chief Officers to take appropriate disciplinary action if their subordinates fail to comply with the policies established by this General Order. F. Hydrogen Cyanide readings will be taken at every working incident and will be documented properly. RESPONSIBILITIES OF COMPANY OFFICERS It shall be the responsibility of each Company Officer to ensure that SCBAs are available in sufficient numbers on the apparatus under their command and that all personnel under their command abide by this General Order. Page 3 of 4 General Order 9.01
4 RESPONSIBILITIES OF INVESTIGATORS Investigators shall don respiratory protective equipment when it is necessary to enter a fire building or any area where a toxic environment may exist to conduct investigations. Page 4 of 4 General Order 9.01
5 DECATUR TOWNSHIP FIRE DEPARTMENT GENERAL ORDER TITLE: ESO DOCUMENTATION NUMBER: 9.02 EFFECTIVE: JULY 1, 2014 THIS ORDER SUPERSEDES ALL PREVIOUS GENERAL ORDERS, POLICIES, RULES, S.O.G S & S.O.P S UPDATED: FEBRUARY 15, 2017 This policy is for internal use only and does not enlarge an employee s civil liability in any way. The policy should not be construed as creating a higher duty of care, in an evidentiary sense, with respect to third party civil claims against employees. A violation of this policy, if proven, can only form the basis of a complaint by this department for non-judicial administrative action in accordance with the laws governing employee discipline. I. PURPOSE II. POLICY To establish departmental policy for ESO Information Documentation. A. All companies shall obtain at minimum the following information for ESO documentation: 1. Name (this might include person involved, occupant, owner, company, etc.) 2. Address 3. Phone Number 4. Vehicle Insurance Information (When applicable) 5. Vehicle Identification Number and License Plate Number (When applicable) 6. Vehicle Year, Make and Model (When applicable) 7. A descriptive narrative of the events of the incident B. The above listed information shall be obtained on all runs. However, the EMS report will be sufficient when only an ambulance is dispatched C. Officers should obtain as much information as possible (date of birth s, vehicle type, etc.) D. Social Security numbers shall not be entered into ESO Fire Reports. Page 1 of 2 General Order 9.02
6 E. You may also have multiple inquiries dependent upon the type of run. Example: If you respond to a building alarm and a representative shows up on the scene then you would have two inquiries, one would be the business and the other would be the representative. Narratives shall include all pertinent information (what was done on the scene and any other pertinent information). F. It shall be the responsibility of the first arriving Company Officer to ensure all information is obtained and entered properly into ESO. G. All responding apparatus shall enter a narrative in ESO. If the apparatus was disregarded enroute note the disregard in the narrative section of ESO H. All reports shall be completely and accurately filled out, immediately upon the completion of a run and the equipment being returned to service. This shall also include the entering of data into the proper record keeping system. I. It shall be the responsibility of the Company Officer to ensure all necessary reports are completed within the scheduled shift unless a situation prevents a report from being completed. (i.e. a fire that is under investigation) Page 2 of 2 General Order 9.02
7 DECATUR TOWNSHIP FIRE DEPARTMENT GENERAL ORDER TITLE: INCIDENT / FIRE SCENE AUTHORITY FIRE INVESTIGATIONS NUMBER: 9.06 EFFECTIVE: JULY 1, 2014 THIS ORDER SUPERSEDES ALL PREVIOUS GENERAL ORDERS, POLICIES, RULES, S.O.G S & S.O.P S UPDATED: FEBRUARY 15, 2017 This policy is for internal use only and does not enlarge an employee s civil liability in any way. The policy should not be construed as creating a higher duty of care, in an evidentiary sense, with respect to third party civil claims against employees. A violation of this policy, if proven, can only form the basis of a complaint by this department for non-judicial administrative action in accordance with the laws governing employee discipline. I. PURPOSE II. POLICY To establish command authority at an incident/fire scene being investigated by members of the Fire Investigations Unit (FIU). A. The Decatur Township Fire Department recognizes the importance of a wellprotected fire crime scene and the value of evidence contained therein as well as the obligation of the suppression companies duty to maintain control over working fires. B. The scene of a fire of questionable origin is to be maintained and kept free from contamination which may cause the loss of valuable evidence and minimizes firefighters' time loss due to courtroom testimony at later dates. III. PROCEDURE A. The first arriving Company Officer and/or Incident Commander shall have the initial investigation and suppression authority until the appropriate investigative authority arrives on the scene. At that time, the investigative authority lies with the FIU. B. The first arriving Company Officer and/or Incident Commander shall assist the Fire Investigator by ensuring that: 1. A rope or barrier tape perimeter with one entry point to the incident scene is established at all scenes where there is a serious injury or fatality, and wherever else deemed appropriate. 2. Notify police dispatcher to ensure sufficient staffing and equipment is provided to control pedestrians and vehicle traffic. Page 1 of 2 General Order 9.06
8 3. Any other action deemed appropriate is taken to preserve the scene and the evidence contained therein. C. Upon arrival of investigative authority (FIU investigator) at the scene the Company Officer and/or Incident Commander will retain authority over fire suppression and assist the FIU investigator with any and all reports or provide any other assistance requested. However, once the fire has been extinguished, the incident location becomes a crime scene and FIU officers, regardless or rank, assume charge and responsibility. D. If a fire breaks out after the arrival of the FIU, it is understood that the suppression companies are in charge of the suppression of fire. E. After the perimeter of the incident scene is established, no personnel, regardless of rank, will be permitted to enter the scene without permission of the assigned FIU Investigator having control of the scene. F. Personnel will not be permitted to interfere with the investigation, or alter or disturb anything that may be considered to be evidence. G. On scene personnel will not touch, move or otherwise contaminate any evidence within the incident scene except for those who are authorized to examine and collect such evidence. 1. Evidence may not be removed or altered in any manner with the possible exception of overhauling operations needed to find and extinguish hidden fires. 2. Evidence may be removed or altered only if it poses a threat to human life or there is a chance the evidence may be destroyed by weather or other conditions at the scene. H. In the event of a fatality at a fire scene, the Homicide Branch of the Indianapolis Metropolitan Police Department will have control of the fire scene after fire suppression, until no foul play in the incident is determined. After that determination is made the FIU will assume responsibility for the fire scene. I. If the FIU desires to take command from the Incident Commander prior to the scene being turned over to the FIU the investigator shall show justifiable cause which may include: 1. Prior intelligence knowledge of an impending arson 2. Prior knowledge of alleged arson patterns in a given area Page 2 of 2 General Order 9.06
9 DECATUR TOWNSHIP FIRE DEPARTMENT GENERAL ORDER TITLE: CHILD SAFETY SEAT INSPECTION STATION PROGRAM NUMBER: 9.07 EFFECTIVE: June 18, 2014 THIS ORDER SUPERSEDES ALL PREVIOUS GENERAL ORDERS, POLICIES, RULES, S.O.G S & S.O.P S UPDATED: FEBRUARY 15, 2017 This policy is for internal use only and does not enlarge an employee s civil liability in any way. The policy should not be construed as creating a higher duty of care, in an evidentiary sense, with respect to third party civil claims against employees. A violation of this policy, if proven, can only form the basis of a complaint by this department for non-judicial administrative action in accordance with the laws governing employee discipline. I. PURPOSE II. POLICY Decatur Township Fire Department is a permanent car seat fitting and distribution station certified by the Automotive Safety Program. This General Orders serves to establish a policy for the Child Safety Seat Inspection Station Program. A. Only certified Child Passenger Safety Technicians can install, inspect or distribute car seats or related equipment. B. Any person requesting car seat inspection, installation or distribution shall be referred to the Child Safety Seat Inspection Station Coordinator. C. If a request is received outside of normal business hours obtain the requestors name, address, address and phone number. Forward this information to the Child Safety Seat Inspection Station Coordinator. D. Car seats, all accompanying equipment, and proper documentation shall remain in a secure location. This location may only be accessed by the Division Chief of Fire and Life Safety and Child Passenger Safety Technicians. E. Child Passenger Safety Seat Technicians shall ensure all paperwork is properly filled out prior to installing, inspecting or distributing car seats and related equipment F. Child Passenger Safety Seat Technicians shall complete the required data and present data to the Division Chief of Fire and Life Safety upon request. Page 1 of 1 General Order Child Safety Seat Inspection Station
10 DECATUR TOWNSHIP FIRE DEPARTMENT GENERAL ORDER TITLE: SCBA MAINTENANCE NUMBER: 9.08 EFFECTIVE: May 1, 2016 THIS ORDER SUPERSEDES ALL PREVIOUS GENERAL ORDERS, POLICIES, RULES, S.O.G S & S.O.P S UPDATED: FEBRUARY 15, 2017 This policy is for internal use only and does not enlarge an employee s civil liability in any way. The policy should not be construed as creating a higher duty of care, in an evidentiary sense, with respect to third party civil claims against employees. A violation of this policy, if proven, can only form the basis of a complaint by this department for non-judicial administrative action in accordance with the laws governing employee discipline. I. PURPOSE To establish Decatur Township Fire Department policy concerning employee responsibility for individual SCBA face pieces. II. DEFINITION III. POLICY SCBA: self-contained breathing apparatus FACE PIECE: the portion of the SCBA that fits over the employee s face and connects to the supply line from the SCBA. OSHA: Occupational Health and Safety Administration; an enforcement agency of the federal government responsible for health and safety in the work place. A. It is the responsibility of each Decatur Township Fire Department employee to possess, properly maintain and clean the SCBA face piece provided by the fire department. This face piece includes the breathing valve, breathing valve body, exhaust port, speech diaphragm, and a high pressure hose that has a male fitting to accommodate the connection to the manifold block. B. Employees are required to inspect their face piece each duty day. Any defects or contamination found during the daily inspection shall be reported. The Company Officer will contact the proper authority to repair or replace any damaged face piece. The owner of the face piece will be responsible for cleaning, inspecting, and reporting damage to their personal face piece. Page 1 of 2 General Order 9.08 Pascal Arnes-Chief of Fire
11 C. Employees shall attach their face piece to the assigned SCBA and perform a leak function test as described in Appendix E of the written respiratory program. D. Maintenance of face pieces is provided by the Decatur Township Fire Department. Only a Scott Authorized Service Specialist or above shall perform maintenance on an SCBA face piece. These technicians shall only use Scott and NIOSH approved parts. E. The SCBA face piece shall not be used if there is damage restricting the proper fit. F. If the employee s SCBA face piece is replaced, the SCBA work order form shall be completed with the proper information. G. If there are significant changes in the employee s ability to wear a respirator or if observations deem that the employee is experiencing difficulty with the respirator, then fit testing may be conducted more often than an annual basis. H. All Scott brand face pieces shall be serviced and re-certified annually. A complete function test shall be performed after each dismantling and assembly related to a repair or service. I. It is the sole responsibility of the employee to clean their assigned face piece after each use. Employees shall follow the procedures listed in Appendix B-2 or Appendix D of this Written Respiratory policy. J. Employees shall not have any facial hair or other obstructions that interfere with the mask-to-face piece seal or valve function. K. If an employee wears corrective glasses, goggles, or any other protective equipment, that equipment cannot interfere with the face-to-face piece seal or valve function. L. It is the Company Officers' responsibility to ensure that each individual under their command is in possession of a fully functional OSHA approved SCBA face piece. Page 2 of 2 General Order 9.08 Pascal Arnes-Chief of Fire
TABLE OF CONTENTS PART 11 - FIREFIGHTING
TABLE OF CONTENTS PART 11 - FIREFIGHTING Page DEFINITIONS...11-1 APPLICATION...11-1 GENERAL REQUIREMENTS...11-2 PERSONAL PROTECTIVE CLOTHING AND EQUIPMENT FOR FIREFIGHTERS...11-2 SELF-CONTAINED BREATHING
More information6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE
SCBA MAINTENANCE SCOPE Stoney Point Fire Department Self-contained breathing apparatus provides respiratory protection under conditions of oxygen deficiency or in concentrations of toxic gases immediately
More informationArticle 203 Self-Contained Breathing Apparatus (SCBA)
1 of 5 Article 203 Self-Contained Breathing Apparatus (SCBA) Section 203.1: Purpose The purpose is to establish guidelines to indicate the proper operation, use, training, and maintenance of self-contained
More informationWestbrook Fire & Rescue Department Standard Operating Procedure
2017-103 Respiratory Protection Program Westbrook Fire & Rescue Department Standard Operating Procedure Section: Administrative TOPIC: Respiratory Protection Program NUMBER: 2017-103 ISSUE DATE: December
More informationTownship Of Jackson, Fire District 3, Station 55 Standard Operating Guidelines TWO IN TWO OUT
Guideline # 310.06 Township Of Jackson, Fire District 3, Station 55 Standard Operating Guidelines TWO IN TWO OUT Date: 3/07 R PURPOSE To establish standard guidelines and procedures that will serve to
More informationSALEM TOWNSHIP FIRE DEPARTMENT RESPIRATORTY PROTECTION PROGRAM
SALEM TOWNSHIP FIRE DEPARTMENT RESPIRATORTY PROTECTION PROGRAM PURPOSE In accordance with Michigan s Occupational Health Standards, Part 451, Respiratory Protection requires that a written Respiratory
More informationYakima County Fire District 12 Standard Operating Guidlines SOG 2-11 Interior Structure Firefighting
Yakima County Fire District 12 Standard Operating Guidlines SOG 2-11 Interior Structure Firefighting REFERENCES: WAC 296-305-05001 (8) WAC 296-305-05001 (10) WAC 296-305-05001 (11) Policy 1201, 2103, 2123,
More informationRespiratory Protection Self Inspection Checklist
Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Respiratory Protection Self Inspection Checklist Guidelines: This checklist covers some
More informationTo establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires.
Buxton Fire-Rescue Standard Operating Guideline Subject: Structural Fire (3) Section: Operations at Structure Fires (2) Page 1 of 7 Purpose: To establish a guideline for the safe and effective deployment
More informationWilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087
SOG Name: One and Two Family Dwellings SOG Number: 403.18 Effective Date: February 2, 2015 Approved: Joey Cooper, Director Reviewed: Scope This procedure will provide an organized method in which to carry
More informationThis program shall contain, as a minimum, the following components:
Section 1: Introduction 1.1 Policy It is the policy of the Pemberton Township Fire Department to maintain comprehensive safety and occupational health programs predicted upon sound engineering, education,
More informationELYRIA TOWNSHIP FIRE DEPARTMENT TRAINING COMPLEX STANDARD OPERATING PROCEDURES. Effective Date: 02/20/12 Revised: 02/12
STANDARD OPERATING PROCEDURES Effective Date: 02/20/12 Revised: 02/12 Title: Use of Burn Facility by Fire Departments for Live Fire Training PURPOSE: To ensure a safe and environmentally sound controlled
More informationTremont Volunteer Fire Department Respiratory Protection Plan
Tremont Volunteer Fire Department Respiratory Protection Plan PURPOSE: This respiratory protection program is designed to provide a standard operating policy for the Tremont Volunteer Fire Department (TVFD).
More informationRESPIRATORY PROTECTION PROGRAM
RESPIRATORY PROTECTION PROGRAM Compliant to 29 CFR 1910.134 NEW MEXICO STATE UNIVERSITY Las Cruces, New Mexico Environmental, Health & Safety (EH&S) 505-646-3327 http://safety.nmsu.edu NMSU Respiratory
More informationCHESTERFIELD COUNTY FIRE AND EMERGENCY MEDICAL SERVICES PROCEDURES
CHESTERFIELD COUNTY FIRE AND EMERGENCY MEDICAL SERVICES PROCEDURES Division: Emergency Operations Procedure: Emergency Operations #24 Subject: Toxic Exposure Reduction Supersedes: Authorized by: Deputy
More informationEgg Harbor Fire Department and First Responders Standard Operating Policy
Egg Harbor Fire Department and First Responders Standard Operating Policy SUBJECT: RESPIRATORY PROTECTION PROGRAM SOP 1206 PURPOSE: SCOPE: To have in place a policy that meets SPS 330.12 (1) (c). This
More informationFire Apparatus Operator (FAO)
Fire Apparatus Operator (FAO) 1106 NATURE OF WORK This is skilled fire fighting work in combating, extinguishing, and preventing fires, in responding to render emergency medical services, in responding
More informationSOUTH LYON FIRE DEPARTMENT Manual of Procedures 300
RESPIRATORY PROTECTION PROGRAM Issued Date: March 23, 2011 Revised: March 25, 2016 Approved: Chief Mike Kennedy I. SCOPE General Industry standard 1910.134 of the Michigan Occupational Health Standards
More informationIdaho Fire Service Technology Fire Fighter II
ICS Skill Requirements Skill Sheet: 1 STANDARD: 6.1.2 TASK: Organize, coordinate, and function within an incident management system. PERFORMANCE OUTCOME: The candidate shall be able to determine the need
More informationRespiratory Protection Self-Inspection Checklist
Respiratory Protection Self-Inspection Checklist Guidelines: This checklist applies to the use of either atmosphere-supplying or air-purifying respirators being worn, voluntarily or otherwise, for comfort
More informationThe Following information is based on material prepared by the American Lung Association
The Following information is based on material prepared by the American Lung Association RESPIRATORY PROTECTION FROM INHALATION HAZARDS The inhalation of harmful dusts, toxic gases and vapors at fire and
More informationGEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures IVN Authority: Effective Date: Page 1 of WETHERINGTON/HODGE 4/01/02
GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures Functional Area: SUPPORT SERVICES/FIRE SERVICES Subject: OCCUPATIONAL SAFETY & HEALTH/PROTECTIVE CLOTHING AND EQUIPMENT 8 Revises Previous
More informationE3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING
E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING Leader s Guide 2007 ERI Safety Videos THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING This easy-to-use Leader s Guide is provided to assist
More informationPOLICY AND PROCEDURE DIVISION OF FIRE AND RESCUE SERVICES
Page 1 o Page 1 of 12 RESPIRATORY PROTECTION POLICY Issued by: Fire Chief Policy No. 26-06AM Authority: Code Section 21-2.(d)(4) Effective Date: April 15, 2005 SUMMARY: ADDRESS: STAFF: BACKGROUND: This
More informationPOSITION DESCRIPTION City of Monett
POSITION DESCRIPTION City of Monett Monjob63 JOB TITLE: Fire Lieutenant DEPARTMENT: Monett Fire and Rescue SALARY RANGE: Payroll Level 9 IMMEDIATE SUPERVISOR: Fire Captain ESSENTIAL FUNCTIONS I. Fire Fighting,
More informationRespiratory Protection
Respiratory Protection Review the Department Policy OSHA Definitions Understanding your Risk Who to contact if you have an exposure incident / question. Policy Location Each station has a binder labeled
More informationProtective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres
Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres Working in an area with insufficient oxygen Situations where harmful dusts,
More informationTEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY
Page 1 of 9 ISSUED: 5/00 REVISED: 08/06 Introduction Purpose: In accordance with applicable regulations and Temple University, this policy was developed to minimize exposure to Ethylene Oxide. Applicability
More informationCedarville Township Volunteer Fire Department Fire Department Standard Operating Guidelines 2008
Cedarville Township Volunteer Fire Department Fire Department Standard Operating Guidelines 2008 1. Your personal safety is your first priority 2. Always operate equipment safely and under control. A vehicle
More informationHAZARDOUS INCIDENT SITE SAFETY PLAN
HAZARDOUS INCIDENT SITE SAFETY PLAN NOTE: A site-specific Site Safety Plan must be developed and implemented for each site where investigators may potentially be exposed to hazardous substances while conducting
More informationSOUTH LYON FIRE DEPARTMENT Manual of Procedures 403
PERSONAL PROTECTIVE EQUIPMENT Issued: June 1, 2012 Revised: September 25, 2015 Approved: Chief Mike Kennedy I. SCOPE This procedure applies to all employees required to work in hazardous environments.
More informationNFPA 1500 Fire Department Occupational Safety & Health Program Worksheet (2013 Edition)
NFPA 1500 Fire Department Occupational Safety & Health Program Worksheet (2013 Edition) NFPA 1500, the Standard on Fire Department Safety and Health Program specifies the minimum requirements for an occupational
More informationSAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures
Number K-3.0 Issued: 1/2009 Revised: 3/2016 Page 1 of 3 1.0 PURPOSE: To standardize procedures associated with production and maintenance welding and to minimize the potential risk of accident or injury
More informationSCARBOROUGH FIRE DEPARTMENT 246 U. S. ROUTE 1 SCARBOROUGH, MAINE TEL: (207) FAX: (207)
Respiratory Protection Plan Revised 12/31/2015 Program Administrator Fire Chief B. Michael Thurlow 730-4201 Safety Officer Captain George Oliver 730-4209 Fire Department Physician (PLHCP) Dr. Jeanne Scheddel
More informationKey Technology, Inc. Confined Space Entry Program. July, 2017
Key Technology, Inc. Confined Space Entry Program July, 2017 Page 1 of 11 Key Technology, Inc. CONFINED SPACE ENTRY PROGRAM OVERVIEW Purpose: The purpose of this program is to ensure the protection of
More informationUNIT OBJECTIVES Upon completion of this unit of study, the student should be able to:
BASIC FIRE FIGHTER ORIENTATION AND COMMUNICATIONS Orientation and Communications 1 UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: 1. Identify the organization of
More informationCity of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015
A. Executive Summary and Introduction City of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015 1. Annual fit test is required for all employees who will be required to wear a respirator as a part
More informationRespiratory Protection
Respiratory Protection University of Tennessee Safety Program IH-003 Document Contact: EHS-General Safety Date effective: January 1, 2006 Revision Date: March 1, 2014 Purpose It shall be the policy of
More informationA. Evaluation of the written program
A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in
More informationCOLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL
COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL (Hand, Eye, Face, Head, Foot, and Respiratory) Effective October 15, 1995 Page 1 of 15 Updated September 2010 A. At the request of the College Safety
More informationTownship of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05
Standard Operating Guidelines Page: 1 of 8 15.05 Scope: This procedure will provide an organized method in which to carry out the fire ground functions in a timely and safe manner. Discussed will be the
More informationWest Clinton Fire District
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 West Clinton Fire District Best Practice Respiratory Protection Program Best
More informationManhattan Fire Protection District
SOP #: 200-6 Effective Date: 02/28/17 Revised Date: Section: Protective Clothing and Equipment Subject: Hydrogen Cyanide Monitoring PURPOSE: The purpose of this standard operating procedure is to provide
More informationThis written Compressed Gas Plan is kept at the corporate office and in the written Safety & Health Program.
Safety & Health Program 10627 Midwest Industrial Boulevard, St. Louis, MO Phone: 314-785-6425 Fax: 314-785-6426 Compressed Gas Plan Purpose It is the policy of EMA to permit only trained and authorized
More informationCONFINED SPACE PROGRAM
CONFINED SPACE PROGRAM Last updated: November 2017 1.0 PURPOSE Entry into a confined space represents a significant risk of serious injury or death to individuals not prepared for the hazards they may
More informationCabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.
Calvin College Respiratory Protection Program Prepared by: Date: Heather Chapman 10/7/10 Approved by: Cabinet Revision 2 Date: 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory
More informationHEALTH AND SAFETY MANUAL
HEALTH AND SAFETY MANUAL Title: Hydrogen Sulfide (H 2 S) Safety Approved by: Greg Savoy Rev. 4/1/08 1 Purpose/Scope: The purpose of this program is to establish minimum requirements for site specific H
More informationRESPIRATORY PROTECTION PROGRAM
A P P E N D I X 14 RESPIRATORY PROTECTION PROGRAM AP14.1. Purpose. AP14.2. Policy. To establish a written Respiratory Protection Program for CBP. The purpose of an effective respirator program is to provide
More informationFIRE FIGHTER II JPR: FFII-1A
JPR: FFII-1A STANDARD: 6.1.2 Task: Implement Incident Management System. General Requirements The candidate shall demonstrate the ability to determine need for command, organize and coordinate an incident
More informationRESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection
RESPIRATORY PROTECTION PROGRAM 1910.134 OSHA Respiratory Protection Table of Contents Introduction... 3 Scope... 3 Definitions... 3 Responsibilities... 5 Voluntary Use... 6 Use Requirements... 6 Program
More informationOSHA: GUIDELINES FOR EMERGENCY PREPAREDNESS AND RESPONSE
OSHA: GUIDELINES FOR EMERGENCY PREPAREDNESS AND RESPONSE 1.0 INTRODUCTION The importance of an effective workplace safety and health program cannot be overemphasized. There are many benefits from such
More informationBREATHE SAFELY: The Proper Use of Respiratory Protection
BREATHE SAFELY: The Proper Use of Respiratory Protection This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of
More informationConfined Spaces. 1. Definition Permit/Non-Permit
1. Definition Permit/Non-Permit Confined Spaces A. Non-Permit Required Confined Space: 1. Large enough and so configured that an employee can bodily enter and perform assigned duties. 2. Has a limited
More informationChapter 1 FF I Orientation and Fire Service History
Chapter 1 FF I Orientation and Fire Service History After completing this lesson, the student shall be able to describe how the history and culture of the fire service influence its basic mission, the
More informationGalva Fire Department SOP
Galva Fire Department SOP GENERAL REGULATIONS All firefighters must know and understand the SOG s set forth by the GFD. GFD personnel will be alerted of a call by pager, fire phone or by the fire siren
More informationUniversity of Dayton Respiratory Protection Program 29 CFR
University of Dayton Respiratory Protection Program 29 CFR 1910.134 What to expect from this training: Employees who are required to use respirators must be trained such that they can demonstrate knowledge
More informationThe Johns Hopkins University/The Johns Hopkins Hospital Health, Safety and Environment Manual Safety Policies:
Page 1 of 6 Keywords: Airborne Combustible, Atmospheric Monitoring, Atmospheric Oxygen, Authorized Entrant, Body Harness, Combustible Gas Meter, Communication Procedure, Confined Space, CPR, Entry, Entry
More informationCOMPLIANCE WITH THIS PUBLICATION IS MANDATORY
BY ORDER OF THE COMMANDER TINKER AIR FORCE BASE TINKER AIR FORCE BASE INSTRUCTION 48-103 2 SEPTEMBER 2015 Aerospace Medicine RESPIRATORY PROTECTION PROGRAM COMPLIANCE WITH THIS PUBLICATION IS MANDATORY
More informationPersonal Protective Equipment 29 CFR 1926
Personal Protective Equipment 29 CFR 1926 OSHA- PPE http://www.osha.gov/publications/osha31 51.html NIOSH s Protective Clothing Web Page http://www.cdc.gov/niosh/npptl/topics/prot clothing/ 1926.95 PPE
More informationBUSINESS OF THE CITY COUNCIL CITY OF MERCER ISLAND, WA
BUSINESS OF THE CITY COUNCIL CITY OF MERCER ISLAND, WA AB 4189 June 4, 2007 Regular Business SELF CONTAINED BREATHING APPARATUS Proposed Council Action: Approve SCBA Replacement Plan. DEPARTMENT OF COUNCIL
More informationEMS and Hazardous Materials Operations
Session Reference: 1 Level of Instruction: Time Required: Two Hours EMS and Hazardous Materials Operations Instructor Guide Materials: Audio-visual equipment to project any visuals 2000 Emergency Response
More informationCHAPTER THREE JOB DESCRIPTIONS
3.01 FIREFIGHTERS/PARAMEDICS A. Nature of Work CHAPTER THREE JOB DESCRIPTIONS This is highly skilled and technical-firefighting and emergency medical work in the preservation of life and protection of
More informationPosition Number Community Division/Region Yellowknife North Slave
IDENTIFICATION Department Position Title Infrastructure Shift Supervisor Firefighter Position Number Community Division/Region 33-7797 Yellowknife North Slave PURPOSE OF THE POSITION The Shift Supervisor
More informationEntry to these spaces must be rigorously controlled to prevent serious injury or death.
Chapter 6 - Confined Spaces Chapter 6 Confined Spaces Definitions A confined space is defined as any structure that must be entered and that has or may contain dangerous concentrations of hazardous gases
More informationFACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision
FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision 1.0 Intent: 2.0 Scope: It is the intention of the University at Albany to provide a
More informationRespiratory Protection. Program
Respiratory Protection Program Respiratory Protection Program Table of Contents A. General B. Selection of Respirators C. Medical Screening D. Fit Testing E. Respirator Use Instructions F. Respirator Inspection
More informationMine Rescue Certification Training Standard
Mine Rescue Certification Training Standard Mine Rescue Certification Training Standard Employers who have workers working in an underground workplace shall take the necessary precautions to ensure worker
More informationSTATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS Office of the Adjutant General St. Francis Barracks, P.O. Box 1008 St. Augustine, Florida
STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS Office of the Adjutant General St. Francis Barracks, P.O. Box 1008 St. Augustine, Florida 32085-1008 ADMF 19 September 1985 DEPARTMENT OF MILITARY AFFAIRS
More informationALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM
ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM Risk Management Department August, 2008 ALBUQUERQUE PUBLIC SCHOOLS RISK MANAGEMENT DEPARTMENT RESPIRATORY PROTECTION PROGRAM TABLE OF CONTENTS
More informationRespiratory Protection
Respiratory Protection Purpose The purpose is to establish a set of guidelines for the selection of respiratory protection equipment, situations for its use, and training in the use of the respirator required.
More informationVolunteer Firefighter Applicant Information Package
Volunteer Firefighter Applicant Information Package INTRODUCTION TO THE KINGSVILLE FIRE DEPARTMENT The Kingsville Fire Department provides emergency fire and rescue service to the residents of the Town
More informationCHAPTER 15 RESPIRATORY PROTECTION
CHAPTER 15 RESPIRATORY PROTECTION 1501. Discussion a. This chapter establishes requirements and responsibilities for an ashore respiratory protection program. Reference 15-1 covers respiratory protection
More informationINCIDENT MANAGEMENT SYSTEM AND TACTICAL OPERATIONS MANUAL
Series 354 Rapid Intervention Team(RIT) Page 1 of 6 INCIDENT MANAGEMENT SYSTEM AND TACTICAL OPERATIONS MANUAL OPERATIONAL GUIDELINE RAPID INTERVENTION TEAM (RIT) SERIES 354 PURPOSE Fire departments are
More informationBlack Butte Ranch R.F.P.D. Fire Fighter/EMT Paramedic Job description DEFINITION: DISTINGUISHING CHARACTERISTICS: SUPERVISION RECEIVED AND EXERCISED:
Black Butte Ranch R.F.P.D Fire Fighter/EMT Paramedic Job description Updated: Sept. 04 2008 Civil Service Approved: Sept. 04 2008 Board of Directors Approved: Sept. 25, 2008 DEFINITION: The fundamental
More informationConfined Space Entry Written Program
Confined Space Entry Written Program Northeast Metro 916 Intermediate School District General District Policy The purpose of this program is to inform interested persons, including employees that Northeast
More informationTexas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)
Texas Department of Insurance Respiratory Protection Provided by Workers Health & Safety HS01-027B (1-06) Contents Introduction... 3 Definitions... 3 Approved Respirators... 3-4 New Respirator Selection
More informationCounty of Louisa Department of Emergency Services
County of Louisa Department of Emergency Services Firefighter/EMT Core Competencies Outlined below are the Core Competencies to which a Firefighter/EMT aspires. These competencies have been divided into
More informationTown of Brookfield Fire Department
645 Janacek Road Brookfield, WI 53045 (262) 796-3792 Fax: (262) 796-0410 Firefighter/Emergency Medical Technician This job description replaces any previously dated job descriptions for this position.
More informationCENTRAL ZONE OPERATIONS MANUAL
Number: Title: Page 1 of 6 PURPOSE The purpose of this policy is to establish the minimum standards and requirements needed for Central Zone Fire Departments to comply with all applicable regulations including
More informationModel XSMKIT. Operations and Instructions WARNING
Xcaper Enterprise Smoke Mask Kit Model XSMKIT Operations and Instructions WARNING THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE, OR WILL HAVE, THE RESPONSIBILITY FOR USING THE
More informationNorth Carolina Fire and Rescue Commission Live Fire Audit Form
Live Fire Audit Form Date of Burn: Address: Delivery Agency AHJ: Instructor in Charge: Written documentation received from owner: Evidence of clear title. Written permission secured from owner to burn
More informationPROTECTIVE CLOTHING SOG
PROTECTIVE CLOTHING SOG SCOPE This guideline shall apply to all members of the Stoney Point Fire Department (SPFD) and shall be adhered to by all members. PURPOSE The purpose of this SOG is to provide
More informationRENO POLICE DEPARTMENT GENERAL ORDER
RENO POLICE DEPARTMENT GENERAL ORDER This directive is for internal use only and does not enlarge this department s, governmental entity s and/or any of this department's employees' civil or criminal liability
More informationSUN PEAKS FIRE RESCUE
SUN PEAKS FIRE RESCUE Everyone Goes Home Welcome to Sun Peaks Fire Rescue On behalf of all of the members of Sun Peaks Fire Rescue, I would like to thank you for expressing interest in our department.
More informationHAZ MAT RESPONSE SOG
SCOPE HAZ MAT RESPONSE SOG This guideline shall apply to all members of the Stoney Point Fire Department and shall be adhered to by all members. PURPOSE This guideline is specifically applicable to known
More informationNATURAL GAS RESPONSE SOG
SCOPE NATURAL GAS RESPONSE SOG This guideline shall apply to all members of the Stoney Point Fire Department and shall be adhered to by all members. PURPOSE The purpose of this guideline is to explain
More informationRESPIRATORY PROTECTION PROCEDURE
RESPIRATORY PROTECTION PROCEDURE 1. PURPOSE The purpose of this procedure is to protect the health and safety of University faculty and staff who work in areas that may have irritating or hazardous atmospheres.
More informationCHAPTER 26 WELDING AND CUTTING
CHAPTER 26 WELDING AND CUTTING Revised 7/2010 1 WELDING AND CUTTING Responsibilities 1. The County Safety Officer is responsible for providing appropriate safety instructions for supervisor's use on welding
More informationCONFINED SPACES. Procedures for Permit-required ALTERNATIVE TO A FULL PERMIT ENTRY. Written Programs
THEME nº17: RESPONSIBLE: Confined Spaces (OSHA) Werson Monteiro ALTERNATIVE TO A FULL PERMIT ENTRY Under certain conditions described in the stard, the employer may use alternate procedures for worker
More informationEast Brunswick Fire District #1
Old Bridge Volunteer Fire Company East Brunswick Fire District #1 Standard Operating Guidelines Title: Respiratory Protection Act Function: Procedure Number: Implementation Date: 12/01/2016 Page Number:
More informationPermit-Required Confined Space Entry Program
Safety & Health Program Permit-Required Confined Space Entry Program General Company Policy 10627 Midwest Industrial Boulevard, St. Louis, MO Phone: 314-785-6425 Fax: 314-785-6426 The purpose of this program
More informationYakima County Fire District 12 Standard Operating Guidelines SOG 5-1 Hazardous Materials Operations
1. General Yakima County Fire District 12 Standard Operating Guidelines 1.1 Purpose. This Standard Operating Guideline is intended to provide general guidelines for District personnel in responding to
More informationRESPIRATORS & FIT TESTING
RESPIRATORS & FIT TESTING Presented By: Jamie Papian Licensed Lead & Asbestos Inspector Licensed Lead & Asbestos Abatement Supervisor HUD Housing Quality Standards Inspector State of Iowa, Illinois and
More informationRespiratory Protection Program
Policy 707 Respiratory Protection Program 707.1 PURPOSE AND SCOPE The is committed to preventing injury and illness in the workplace and makes every effort to protect our employees from harmful airborne
More informationSPECIAL OPERATIONS COMMAND (SOC) SUPPORT LADDER COMPANIES
FIRE TACTICS AND PROCEDURES November 3, 2003 SPECIAL OPERATIONS COMMAND (SOC) SUPPORT LADDER COMPANIES 1. INTRODUCTION 1.1 Special Operations Command (SOC) Support Ladder Companies have been formed to
More information! Subpart D - Contingency Plans and Emergency Procedures (40 CFR to ) (EPA regulations adopted by NJDEP); and
APPENDIX D EMERGENCY PROCEDURES IN PUBLIC SECONDARY SCHOOLS IN THE EVENT OF A CHEMICAL SPILL There are five major sources of regulations that are potentially applicable to emergencies involving a chemical
More information2017 Volunteer Week - Course Descriptions
2017 Volunteer Week - Course Descriptions 40 Hour Course - S130/S190/L180 Introduction to Wildland Firefighting S190 This course provides instruction in the primary factors affecting the start and spread
More informationRichland County School District One. Permit-Required Confined Space Entry Program (29 CFR Part )
Richland County School District One Permit-Required Confined Space Entry Program (29 CFR Part 1910.146) 1 PERMIT-REQUIRED CONFINED SPACE ENTRY PROGRAM FOR RICHLAND COUNTY SCHOOL DISTRICT ONE Purpose Richland
More informationRespiratory Protection
Respiratory Protection Everything You Wanted to Know About Respiratory Protection and Probably a Bit More. Instructor: Mary Schlagel Northern Illinois University Environmental Health & Safety Dept. 815-753-0404
More informationRespirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters
UNITED STATES Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters This information is about the respirator fit testing requirements for any worker
More information