LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb.

Size: px
Start display at page:

Download "LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb."

Transcription

1 " 88mm 5" 889mm CBINET DIMENSIONL DT DS DOWNFLOW IR COOLED 5-77kW (15-22 TONS) W/ SCROLL OR DIGITL SCROLL COMPRESSOR MODELS Secondary Refrigerant Piping Entrance 80" 202mm Opening IR INLET OPENING 2 /8" 619mm Opening Note: 1. Filters are accessible through top of unit only. 2. Downflow electrical connections can be made from top or bottom of unit. Secondary Entrance High Volt Connection(s) 1 /" mm Handle TOP VIEW 98" 289mm 5/16" 8mm Bezel Secondary Entrance Low Volt Connections Minimum required for filter replacement 5" 127mm 76" 190mm 2" 51mm FRONT VIEW 97" 26mm Shaded area indicates a recommended minimum clearance be provided for component access. " 86mm Dry Weight (approximate) lb. (kg) Model No. ir Cooled Dual Cool DS (871) 2100 (95) DS (89) 2150 (975) DS (916) 2200 (998) DPN0018 REV : 5 REV DTE : 1/17

2 PRIMRY CONNECTION LOCTIONS DOWNFLOW IR COOLED 5-77kW SCROLL OR DIGITL SCROLL COMPRESSOR MODELS W/ EC FNS X O 1 5" 889mm L1 L2 G1 G2 R ECS ECR 2 CD EC Fan Outlet EC Fan Outlet Y LV1 LV2 LV E1 E2 HUM Section - 98" 289mm Front of Unit POINT DESCRIPTION X in. (mm) Y in. (mm) R DS REFRIGERNT CCESS 81-/ (2076) 1-/ (75) L1 G1 LIQUID LINE SYSTEM 1 HOT GS DISCHRGE /16 (205) 88-/ (225) L2 G2 LIQUID LINE SYSTEM 2 HOT GS DISCHRGE /8 (2) 85-9/16 (217) 16-/ (25) 16-/8 (16) CONDENSTE DRIN 2 CD (infrared humidifier or no humidifier) 68-/8 (177) 1-/8 (797) W/ OPTIONL PUMP HUM HUMIDIFIER SUPPLY LINE 76-1/2 (19) 29 (77) ECS ECON-O-COIL SUPPLY 78-5/8 (1997) 22-1/ (565) ECR ECON-O-COIL RETURN 7-15/16 (1878) 26-9/16 (675) E1 78-1/2 (199) ELECTRICL CONN. (HIGH VOLT) E2 75-/8 (1915) LV1 1-1/8 (791) 29 (77) LV2 ELECTRICL CONN. (LOW VOLT) 2 (51) 0-7/8 (78) LV 2 (81) CONNECTION SIZE / OPENING 12-/16" (10mm) X " (102mm) 5kW (15 TONS) 70 & 77kW (20 & 22 TONS) 1/2" O.D. Cu 7/8" O.D. Cu /" NPT FEMLE 1/2" O.D. Cu 1/" O.D. Cu 2-1/8" O.D. Cu 2-1/2" 7/8" 5/8" O.D. Cu 1-1/8" O.D. Cu Notes: 1. Drawing not to scale. ll dimensions from rear corner of unit including panels, and have a tolerance of ± 1/2" (1mm). 2. Field pitch Condensate Drain line a minimum of 1/8" (.2 mm) per foot (05 mm). ll units contain a factory installed condensate trap. Do not trap external to the unit. Drain line may contain boiling water. Select appropriate drain system materials. The drain line must comply with all local codes.. Supplied on Dual Cooling systems only.. When piping out the top of the unit, install traps in the discharge lines in the bottom of the unit before running lines to the top. 5. Digital Scroll compressor not available on DS077 models. DPN REV : 7 REV DTE : 1/17

3 PIPING SCHEMTIC IR COOLED W/ MC CONDENSER ND WITH & WITHOUT LEE-TEMP Check Relief Service LEE-TEMP RECEIVER LIQUID RETURN Head Pressure Control Check CONDENSER COIL CONDENSER COIL (Includes factory provided inverted trap. No external trap required) HOT GS DISCHRGE (Includes factory provided inverted trap. No external trap required) OPTIONL FIELD INSTLLED FUSIBLE PLUG LEE-TEMP LIQUID 28-2kW digital Solenoid 5-70kW digital Solenoid Sensing Bulb SUCTION EVPORTOR COIL For rises over 25ft. (7.6m), trap every 20ft. (6m) or evenly divided Service Check COMPRESSOR Service External Equalizer Field installed relief valve(s) required for 50Hz EU CE units. 5 Muffler Isolation HOT GS DISCHRGE Expansion Solenoid Sight Glass OPTIONL FCTORY PIPING REFRIGERNT PIPING Filter Drier LIQUID LINE SERVICE/SCHRDER (CCESS) CONNECTION NO VLVE CORE Isolation Trap at base of risers over 5ft. (1.5m) FIELD PIPING Notes: 1. Single refirigeration circuit shown for clarity. 2. Schematic representation shown. Do not use for specific connection locations. SERVICE/SCHRDER (CCESS) CONNECTION WITH VLVE CORE. Components are not supplied by Liebert, but are required for proper operation and maintenance. Traps must be installed and horizontal lines pitched to ensure proper oil return and to reduce liquid floodback to compressor.. Pitch horizontal hot gas piping at a minimum of 1/2" per 10 feet (2mm per 10m) so that gravity will aid in moving oil in the direction of the refrigeration flow. 5. Component supplied by Liebert and must be field installed on units with semi-hermetic compressors (70kW, 77kW, & 105kW models only). DPN0070 REV : 1 REV DTE : 1/17

4 FLOORSTND DIMENSIONL DT DOWNFLOW DS 5-77kW (15-22 TONS) W/ EC FNS Notes: 1. This floorstand should be used when EC fans are intended to be lowered under a raised floor. 2-8" floorstands allow fan to be lowered under raised floor. 2. Right side of paneled unit is flush with right side of floorstand. ll other paneled sides overhang floorstand 1" (25mm).. The floorstand used with EC units is not symmetrical and its orientation to the Liebert DS is critical for lowering the EC fans. Unless the floorstand is installed in the correct position, the blowers will not lower into the floor stand.. Jack and jack support are shipped loose and are intended to be placed into position under each fan and utilized to lower or raise that fan as needed. 5. Leveling feet are provided with u 1-1/2 (8mm) adjustment from nominal height F. 6. pplies to 6", 2" & 8" Floorstand. Piping access area 1 1/2" 800mm at each end 2" 81mm between each end 1" 25mm D C 2 /" 82mm " 88mm 5 F /" 89mm 7/8" 2mm " 76mm B Overall Length 1/2" 876mm t each end 5" 889mm Overall Depth Dimensional Data in (mm) B C D DS05-070, ir-cooled Semi-Hermetic and all 108 (27) 109-1/2 (2781) 106-1/2 (2705) 2-/ (629) Water/Glycol/GLYCOOL Models DS05-070, ir-cooled Scroll and ir-cooled 97 (26) 98-1/2 (2502) 95-1/2 (226) 1-/ (9) Digital Scroll Models DS077, ll Semi-hermetic Models 108 (27) 109-1/2 (2781) 106-1/2 (2705) 2-/ (629) DS077, ir-cooled Scroll Models 97 (26) 98-1/2 (2502) 95-1/2 (226) 1-/ (9 DPN0017 Height in ( mm ) F 5 2 (610) 0 (762) 6 (91) 2 (1067) 8 (1219) REV : REV DTE : 1/17

5 LIEBERT MC CONDENSER 575V Option CBINET & NCHOR DIMENSIONL DT 2 FN (MCS056, MCM080, MCL110) DUL CIRCUIT 575V Option G H TOP OF FN GURD * F C D Entering Hot Gas and Leaving Liquid Piping Lee-Temp or DSE Receiver nchor Plan Full height leg supplied for each Lee-Temp or DSE Receiver required 1/16" 21mm 7" 178mm Left Side of Unit DETIL 5/8" 9mm J Lee-Temp or DSE Only Main Electric Box End ll primary dimensions in tables are in inches (Secondary are in mm) except where specified 1 7/8" 8mm 1/2" (1mm) X 1" (25mm) Obround M L LIEBERT MODEL NUMBER MCS056 MCM080 DIM "G" 1-5/8 (80) 9-5/8 (1260) 61-5/8 (1565) 7-5/8 (1870) DIM "H" 9-5/8 (1006) 57-5/8 (16) 69-5/8 (1768) 81-5/8 (207) MCL110 K 15 1/" 87mm 6 1/2" 6 1/2" 165mm Ref. 165mm Ref. Dual Circuit Only K 15 1/" 87mm Dual Circuit Only Front View (Lee-Temp Shown) F 2 (LEG HEIGHT DIMENSIONS) 18 (57) 6 (91) 8 (1219) 60 (152) DIM "G" 5-7/8 (911) 5-7/8 (168) 65-7/8 (167) 77-7/8 (1978) DIM "H" -5/8 (1108) 61-5/8 (1565) 7-5/8 (1870) 85-5/8 (2175) Note: Typical ll Legs J 1. Liebert recommends a clearance of LIEBERT Lee-Temp 6 (915mm) on each side for proper * MODEL C D or operation and component access. (575V ONLY) NUMBER DSE Receivers K L M 2 Cross bracing required for legs longer Only than 18" (57mm). Quantity varies per MCS /8 (211) 10-1/8 (2619) 88-/8 (225) 86-/ (220) 2-1/2 (1079) 2-1/2 (1080) 0-7/8 (108) 5-7/8 (910) model & options selected. MCM / (267) 11-7/16 (2882) 96-1/16 (20) 9-7/16 (298) 6-5/16 (1177) 6 (1168) -/8 (1127) 9-5/16 (999) For DSE models only, 6-1/2" (165mm) MCL /8 (152) 1-1/8 (81) 112-1/8 (288) 110-1/2 (2806) 5-/8 (181) 55-1/2 (110) 5-7/8 (168) 8-/ (128) dimension is 9-1/" (25mm) and 15-1/ (87mm) dimension is not applicable. DPN007 REV : REV DTE : 12/16

6 LIEBERT MC CONDENSER CONDENSER ND OPTION WEIGHT DT, lb(kg) Condenser Dry Weight Size Small (MCS) Medium (MCM) Condenser Model MCS028 MCS056 MCM00 MCM080 MCM160 Refrigerant Circuits dditional Weight for Options PDX-EEV Receiver Lee-Temp DSE Receiver D050/080/085 DSE Receiver D125/150/ V Transformer Coated Coil Seismic/Wind Bracing 18" legs " Leg 15 ( 70) 270 ( 122) 21 ( 105) 1 ( 200) 1 ( 200) 860 ( 90) 6" Leg 286 ( 10) 19 ( 190) 6 ( 165) 590 ( 268) 590 ( 268) 1066 ( 8) 8" Leg 18 ( 1) 51 ( 205) 95 ( 179) 622 ( 282) 622 ( 282) 111 ( 505) 60" Leg 9 ( 158) 82 ( 219) 26 ( 19) 65 ( 296) 65 ( 296) 1160 ( 526) 5 ( 20) 5 ( 20) 5 ( 20) 55 ( 25) 110 ( 50) 55 ( 25) 100 ( 5) 110 ( 50) 220 ( 100) 88 ( 0) 18 ( 8) 55 ( 25) 65 ( 29) 60 ( 27) 70 ( 2) 70 ( 2) 80 ( 6) ( 2) 8 ( ) 5 ( 2) 10 ( 5) 10 ( 5) 20 ( 9) 0 ( 18) 0 ( 18) 0 ( 18) 0 ( 18) 0 ( 18) 57 ( 26) Size Large (MCL) Condenser Model MCL055 MCL110 MCL165 MCL220 Refrigerant Circuits " Leg ( 156) 602 ( 27) 602 ( 27) 891 ( 0) 1186 ( 58) 1186 ( 58) Condenser Net 6" Leg 86 ( 220) 766 ( 7) 766 ( 7) 116 ( 515) 15 ( 659) 15 ( 659) weight 8" Leg 518 ( 25) 798 ( 62) 798 ( 62) 118 ( 57) 1501 ( 681) 1501 ( 681) 60" Leg 59 ( 29) 829 ( 76) 829 ( 76) 120 ( 558) 157 ( 702) 157 ( 702) dditional Weight for Options PDX-EEV Receiver Lee-Temp 5 ( 20) 60 ( 27) 115 ( 52) 120 ( 5) 175 ( 79) 215 ( 98) 20 ( 109) DSE Receiver D050/080/085 5 ( 20) 90 ( 1) 5 ( 20) 90 ( 1) DSE Receiver D125/150/165 9 ( ) 188 ( 85) 9 ( ) 9 ( ) 188 ( 85) 575V Transformer 67 ( 0) 77 ( 5) 77 ( 5) 118 ( 5) 118 ( 5) 118 ( 5) Coated Coil 8 ( ) 16 ( 7) 16 ( 7) 2 ( 11) 2 ( 15) 2 ( 15) Seismic/Wind Bracing 18" legs 0 ( 18) 0 ( 18) 1 ( 19) 57 ( 26) 57 ( 26) 57 ( 26) Total weight is the sum of 'Condenser' + ('PDX-EEV Receiver' or 'Lee-Temp' or 'DSE Receiver 050/080/085' or 'DSE Receiver 125/150/165')'+'Coated Coil' + '575V Transformer'.+ 'Seismic/Wind Bracing' DPN000 REV : REV DTE : 12/16

FMU4X, FMC4X FMU4P, FMC4P

FMU4X, FMC4X FMU4P, FMC4P ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal

More information

VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU

VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU VRF Technical Data Book DVM S ECO for Europe (R410A, Hz, HP) Model : AM***KXMDGH/EU History Version Modification Date Remark 1 Newly Release the TDB 15.12.15 Nomenclature Outdoor Units Model Names AM 080

More information

MAINLINE MLA14 AIR CONDITIONERS

MAINLINE MLA14 AIR CONDITIONERS FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured

More information

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14**W SERIES FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No. FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to

More information

AIR CONDITIONERS WA14 SERIES

AIR CONDITIONERS WA14 SERIES FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No. FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No. FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7

More information

Supersedes: RP1(495) Form RP1 (1102)

Supersedes: RP1(495) Form RP1 (1102) RENEWAL PARTS CENTRIFUGAL LIQUID CHILLERS Supersedes: 0.9-RP(9) Form 0.9-RP (0) UNIT COMPONENTS MODEL YK (STYLES A & B) WITH MICROCOMPUTER CONTROL CENTER PART #3-000-00 FOR ELECTRO-MECHANICAL STARTER &

More information

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay. Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.

More information

Uniflair LE TDAR-TUAR

Uniflair LE TDAR-TUAR Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) >

More information

Vertical and Horizontal Bladder Tanks

Vertical and Horizontal Bladder Tanks DATA SHEET Vertical and Horizontal Tanks Application The ANSUL bladder tank is one component in a balanced pressure proportioning system. Its operation requires no external power other than a pressurized

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000

More information

The CWE / HWE-R Series: Overview. Frame and cabinet covering

The CWE / HWE-R Series: Overview. Frame and cabinet covering Table Of Contents The CWE / HWE-R Series: Overview...... 1 Frame and cabinet covering... 1 Refrigerant gas...... 2 Compressors...... 2 Condensers...... 2 Fans... 3 Evaporator...... 3 Refrigerant circuit......

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239

More information

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel tapered design primary heat exchanger with crimped construction for long

More information

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES 1990 Nissan 240SX 1983-90 AIR CONDITIONING & HEAT General Servicing Diagnostic Procedures All Import Makes & Models Diagnosis is an important first step in A/C

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet Capacity regulator (hot gas bypass), type TUH/TCHE/ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Capacity regulator (hot gas bypass)

Capacity regulator (hot gas bypass) MAKING MODERN LIVING POSSIBLE Capacity regulator (hot gas bypass) TUH/TCHE/ Technical brochure Contents Page Introduction........................................................................................3

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. Units Date 1/09 Table Of Contents This parts list contains

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control. Document No. CAN7E-P MFB LX Series Modulating Control Valve Description Valves with magnetic actuator for modulating capacity control of refrigeration units and for heat recovery. Features Quick positioning

More information

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions AE19-1132 R8 December 2004 Reformatted November 2010 Copelametic Two-Stage Compressors Application and Service Instructions The Copeland two stage compressors have been developed to efficiently achieve

More information

VARIABLE SPEED AIR CONDITIONERS

VARIABLE SPEED AIR CONDITIONERS FORM NO. AFJ-224 Supersedes Form No. AFJ-222 VARIABLE SPEED AIR CONDITIONERS FO*20C SERIES Efficiencies up to 20 SEER/13 EER Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kw] Cooling Capacities

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

CNG FILLING STATIONS

CNG FILLING STATIONS CNG FILLING STATIONS GAS INLET 3/4 F EXIT CNG TO CAR TANK 5 mt / 16 feet HOSE AND FILLING NOZZLE REMOTE ELECTRIC PANEL THREE-PHASE height 40 cm / 15.7 width 30 cm / 11.8 depth 20 cm / 7.8 EQUIPPED WITH

More information

CHECK VALVES APPLICATIONS

CHECK VALVES APPLICATIONS 45 APPLICATIONS The check valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97//EC, Article 1, Section 2.1.4 and are subject of Article

More information

Water Cooled Condensing Units

Water Cooled Condensing Units Bulletin 502.4A March 2003 (Replaces 502.4 3/02) Water Cooled Condensing Units SWN - Semi-Hermetic Compressor Water Cooled Condensing Units Table of Contents Nomenclature... 2 Features & Benefits...3-4

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

Solenoid valve type EVR for Hydrocarbons

Solenoid valve type EVR for Hydrocarbons MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and

More information

MAINLINE MLP14**A HEAT PUMPS

MAINLINE MLP14**A HEAT PUMPS FORM NO. PML-806 REV. 2 Supersedes Form No. PTZ-789 MAINLINE HEAT PUMPS Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) IMI CORNELIUS INC. www.cornelius.com Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) Publication Number: 631806058 Revision Date: October 13, 2009 Revision: E Visit the

More information

CO 2 radial piston compressor (transcritical)

CO 2 radial piston compressor (transcritical) CO 2 radial piston compressor (transcritical) At a glance Operating limits and performance data Technical data Dimensions and connections Scope of supply 124 126 129 130 131 Radial piston compressor (transcritical)

More information

ECS Protector Nitrogen Inerting Vent (PAV-WN)

ECS Protector Nitrogen Inerting Vent (PAV-WN) ECS Protector (PAV-WN) U.S. Pat. No. 8,636,023, 9,526,933 and 9,717,935 B2 Specifications Stock Number: Service Pressure: Regulator Setting: System Connection: Temperature Range: Dimensions: Weight: Clear

More information

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234. TRAE Stretch series of Thermal Expansion Valves are designed predominantly for AC, heat pumps, close control, industrial process cooling applications, and transportation AC with HP demand. The new TRAE

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Models: DS 126 Single Pump / Single System DT 126 Twin Pump / Single System DS 160

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

KCS-Line. Air Cooled Condensers NEW CONTENTS PRODUCT DATA & INSTALLATION. Refrigerant: R404A, R507, R22

KCS-Line. Air Cooled Condensers NEW CONTENTS PRODUCT DATA & INSTALLATION. Refrigerant: R404A, R507, R22 PRODUCT DATA & INSTALLATION Bulletin K50-KCS-PDI-1 1085695 For 50Hz see Bulletin K50-KCS-PDI-50 We are on the Internet www.keepriterefrigeration.com KCS-Line Air Cooled Condensers Refrigerant: R404A, R507,

More information

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50) Page 1 of 8 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm, flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps - Commercial Table of Contents Model Explanation...................................................................................................................

More information

DATA & FACTS Compressor-Condensing Unit GLCU BC1/2(.SL) Air-Cooled Compressor Condensing Unit for Outdoor Installation

DATA & FACTS Compressor-Condensing Unit GLCU BC1/2(.SL) Air-Cooled Compressor Condensing Unit for Outdoor Installation DATA & FACTS Compressor-Condensing Unit GLCU 2015-4060 BC1/2(.SL) Air-Cooled Compressor Condensing Unit for Outdoor Installation Table of contents GLCU 2015-4051 BC1 Table of Contents... 2 Unit type code...

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

AE R1 February 2015

AE R1 February 2015 February 2015 CoreSense Diagnostics for Copeland Scroll UltraTech Air Conditioning Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to

More information

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Solenoid valves, two-step on/off PMLX REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Micro-S / Micro-S Digital Wall Hung Unit Please fulfil all listed requirements prior to and during

More information

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners

MODEL: SA13. Air Conditioners. Sure Comfort SA13. Air Conditioners 15.5 MODEL: SA13 Air Conditioners FORM NO. ASC-221 REV. 1 Sure Comfort SA13 Air Conditioners Efficiencies 13-15.5 S/11.5-13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5

More information

A/C SYSTEM DIAGNOSIS

A/C SYSTEM DIAGNOSIS A/C SYSTEM DIAGNOSIS 1988 Jeep Cherokee 1988 AIR CONDITIONING & HEAT A/C General Servicing Diagnostic Procedures Jeep; All Models DIAGNOSTIC PROCEDURES Diagnosis is an important first step in A/C system

More information

Industrial Refrigeration Control Valves. Catalog C12-PVS Parker Valve Station (PVS) Sizing Guide

Industrial Refrigeration Control Valves. Catalog C12-PVS Parker Valve Station (PVS) Sizing Guide Industrial Refrigeration Control Valves Catalog C1-PVS Parker Valve Station (PVS) Sizing Guide PVS Sizing Guide PVS Suction Capacities (Tons) Pressure Regulators R-717 Evap Temp, F Evap Press PSI 0 F 74.

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/2) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS

More information

Selection of ICF made easy Save even more time with ICF

Selection of ICF made easy Save even more time with ICF MAKING MODERN LIVING POSSIBLE Selection of ICF made easy Save even more time with ICF ICF stands for valve trains and for over five years installation and service has never been easier. This quick guide

More information

CROT-6 CROT-10 CRO-4. for Compressor Overload Protection

CROT-6 CROT-10 CRO-4. for Compressor Overload Protection May 2010 / RACE Catalogue 90-10 UK for Compressor Overload Protection CROT-6 Listed and y Certified 400 psig Maximum Rated Pressure CROT-10 Listed and Certified 400 psig Maximum Rated Pressure CRO-4 Recognized

More information

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33. EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

TEST BENCH FOR SAFETY VALVES

TEST BENCH FOR SAFETY VALVES TEST BENCH FOR SAFETY VALVES 1) Hydro panel : This Panel possesses This Bench Contains One Panel and One Reservoir. 1 No. Monobloc Version : Single Phase AC, 50 Hz Type of Duty :S1 (Continuous) Class of

More information

GAS SUPPLY DESIGN GUIDE

GAS SUPPLY DESIGN GUIDE GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14

More information

Application Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A

Application Engineering Bulletin AE-1301 Issued June, Copeland APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A 4-1301 Application Engineering Bulletin AE-1301 Issued June, 1996 APPLICATION GUIDELINES FOR ZP**K*E SCROLL COMPRESSORS FOR R-410A Introduction The new model family of "ZP" compressors is designed for

More information

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP 4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for

More information

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking flow control valve to control water flow into the deluge system. The flow control valve must be installed with

More information

FSW SECTION. Product guide. Shut Off Valves, Vibration Eliminators, Accumulators & Oil Separators D SECTION. 55

FSW SECTION. Product guide. Shut Off Valves, Vibration Eliminators, Accumulators & Oil Separators D SECTION.   55 FSW Product guide D SECTION Shut Off Valves, Vibration Eliminators, Accumulators & Oil Separators For more information visit www.fsw.uk.com 55 Danfoss Check Valves (Non-return) Danfoss non-return valves

More information

RPNK. Heat Pumps. Parts List 25-July-2011

RPNK. Heat Pumps. Parts List 25-July-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................

More information

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Name of Property: Address: Phone Number: Inspector: Contract No.: Date: This Report Covers: Monthly Quarterly Annual Other

More information

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, servo-controlled / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant,

More information

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Electric expansion valves Types AKV 10, AKV 15 and AKV 20 Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller

More information

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES 110 AIR CONDITIONING CHILLED WATER PLANT 1. Ensure power to water chiller controller and all fan coil unit controllers is on 2. Ensure chilled water expansion tank level is at its proper level 3. Ensure

More information

Model 3600-R410A. Part No Instruction Operation & Maintenance

Model 3600-R410A. Part No Instruction Operation & Maintenance Model 3600-R410A Part No. 2000-3600 Instruction 2079-0140 Operation & Maintenance Rev. G September 2007 WARNING: INHALATION OF HIGH CONCENTRATIONS OF REFRIGERANT VAPORS IS HARMFUL AND MAY CAUSE HEART IRREGULARITIES,

More information

Installation Operation Maintenance

Installation Operation Maintenance 682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description

More information

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Installation Instructions V48 Issue Date 08/30/01 V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V48 Series 3-Way Pressure-Actuated Water-Regulating

More information

MODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE "C"

MODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE C AIR-COOLED CONDENSING UNIT HERMETIC SCROLL RENEWAL PARTS Supercedes: NONE Form: 150.64-RP2 (105) MODELS YCAL0287, 0317, 0347 and YCAL0377 STYLE "C" YCALMMHPd 90-135 TON 270-457Kw 50 Hz 380/415-3-50 MODELS

More information

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype (R744) Service Station Presentation Contents Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype Page 1 (R744) Service Station Goals Usability Full automatic

More information

Mechanical Seal Piping Plans

Mechanical Seal Piping Plans Mechanical Seal Piping Plans Companion Booklet Single Seals Dual Seals Quench Seals Second. Cont. Dual Gas Introduction A primary factor in achieving highly reliable, effective sealing performance is to

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants V248 Series 3-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Product Code No. LIT-12011515 Issued June 19, 2009 The V248 Series 3-Way Pressure-Actuated Water-Regulating Valves

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature

More information

BEFORE HANDLING REFRIGERANTS, READ MATERIAL SAFETY DATA SHEET FROM REFRIGERANT MANUFACTURER.

BEFORE HANDLING REFRIGERANTS, READ MATERIAL SAFETY DATA SHEET FROM REFRIGERANT MANUFACTURER. Model 3700 Part No. 2000-3700 Instruction 2079-0110 Operation & Maintenance Rev. 3 March 2013 WARNING: INHALATION OF HIGH CONCENTRATIONS OF REFRIGERANT VAPORS IS HARMFUL AND MAY CAUSE HEART IRREGULARITIES,

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Liquid level regulating valves Types PMFL / PMFH and SV

Liquid level regulating valves Types PMFL / PMFH and SV Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve

More information

IRC 2011 All Rights Reserved

IRC 2011 All Rights Reserved 1 2 3 The enthalpy of saturated vapor and the enthalpy of saturated liquid is evaluated at the fully accumulated relief device set pressure (P=P set * 1.1 + 14.7). Set Pressure (psig) h fg (Btu/lbm) 150

More information

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators Page 1 of 6 TI-P510-01 H Issue 5 IP2, IP2 and IP2D ISO 9001 Spirax-Monnier International ompressed ir Filter/ Regulators ert. No. LRQ 0963008 Description The IP range of Spirax-Monnier international compressed

More information

North American 7339 High Pressure Gas Regulators

North American 7339 High Pressure Gas Regulators Combustion North American 7339 High Pressure Gas Regulators Bulletin 7339 7339 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across

More information

FX134, FX1234, FX3030 Problem and Solutions

FX134, FX1234, FX3030 Problem and Solutions FX134, FX1234, FX3030 Problem and Solutions Unit Will Not Power Up Turn the power switch on. The unit LCD will display revision program and filter life within 3 to 5 seconds after turning on unit. If this

More information

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines for the opening against high differential pressure, e.g. after hot gas

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory Agenda Basic Characteristics Background Degree of Superheat, degree of subcooling, average coil temperature Handling and setting

More information

Vaporizer Technique. FAS Flüssiggas-Anlagen GmbH

Vaporizer Technique. FAS Flüssiggas-Anlagen GmbH Cover_Booklet_Premium_ Poland Folder\Links\Cover_ Poland.psd One of the best assorted and largest stock of equipments of any kind destined for all industrial LPG applications within Europe. With more than

More information