User Guide Antidecubitus systems EURO BASIC

Size: px
Start display at page:

Download "User Guide Antidecubitus systems EURO BASIC"

Transcription

1 User Guide Antidecubitus systems EURO BASIC User Guide Euro Basic Rev 06 del 11/2011 pag. 1 di 16

2 INDEX Par. Title Page 1 Instructions 3 2 Standards and directives 3 3 Identifying the device 3 4 Description and components 4 5 Intended use 5 6 Improper and incorrect use 5 7 Warnings 6 8 Control panel 7 9 Installation 7 10 Starting the compressor 8 11 Dynamic and static functioning 8 12 Nursing 8 13 Inflation regulation 8 14 Alarms 9 15 CPR function 9 16 Cleaning the system Fuse replacement Handling and storage Trouble shooting Technical characteristics 21 Waste of disposal 22 Warranty User Guide Euro Basic Rev 06 del 11/2011 pag. 2 di 16

3 Thank you for choosing us! Thank you for choosing our product. We would like to remind you that EuroAusili is in the forefront in the production of aids that prevent decubitus ulcers at different stages. Please read and preserve this booklet carefully. It provides important information on how to use the product and its maintenance. 1. INSTRUCTIONS This document belongs to EuroAusili and it is forbidden to make partial or full copies of it in any way (mechanical or electronic) without permission from the manufacturer. EuroAusili is free to make any useful technical and commercial changes that are believed to be necessary at any time and without notice. Therefore all the data and information reported could be changed or updated. This booklet is given with the product. It is part of it and it is up to the customer to preserve it properly. 2. STANDARDS AND DIRECTIVES Euro Basic anti decubitus systems, produced by EuroAusili, are designed and built according to Medical Devices Directory 93/42/CEE and its revised version. The systems comply to Electrical Safety of Electro Medical Systems Standard CEI EN and to Electromagnetic Compatibility of Electro Medical Systems Standard CEI EN The systems are re-usable. 3. IDENTIFYING THE DEVICE Each system can be identified thanks to three labels: the compressor, the base of the mattress base and the cover, show the model, and the serial number in order to grant each system to be tracked. EuroAusili will not recognise any product if it does not have the identifying label or if the data on it is illegible. The product will thus cease to be under warranty. User Guide Euro Basic Rev 06 del 11/2011 pag. 3 di 16

4 Label Position Symbol Meaning Manuifacturer Back of the compressor Caution! Please consult user manual Production date (month and year) Type B applied part Class II device Do not dispose of as normal waste Characteristics of the fuse Year of production Base of the mattress and bottom of the cover S.N. Serial Number Manuifacturer 4. DESCRIPTION AND COMPONENTS Euro Basic anti-decubitus system is classified as Class I medical devices according to Medical Devices Directory 93/42/CEE and its revised version. User Guide Euro Basic Rev 06 del 11/2011 pag. 4 di 16

5 Eur Basic system is to be used in prevention and therapy of ulcers caused by decubitus and is suitable for body weight from 40 and max. 150 Kg. Euro Basic system includes: - A three way compressor with pressure regulator - Overlay mattress including: 18 inflatable and individually interchangeable elements made of nylon-polyurethane 1 lower case, with straps and snap release buckles in order to fasten it to the bed 1 PES/PU cover 3 tubes which connect the mattress to the compressor The mattress-version (Euro Basic Pro) is obtained by adding a removable PU foam base (4,5 cm). 5. INTENDED USE The system is intended to be used in nursing environments or in private homes to reduce the risk of contracting decubitus ulcers in patients at risk or who already have wounds. The mattress has to be installed according to instructions given in the specific chapter. In order to use the product properly, we suggest you turn to medical or paramedical staff. 6. IMPROPER AND INCORRECT USE Improper and incorrect use description Consequences / remarks Using the system in order to prevent decubitus ulcers on patients who run a higher risk than the one for which the system is meant for. Using the system in order to cure decubitus ulcers on patients who run a higher risk than the one for which the system is meant for. Using the systems with patients that weigh less than 40kg Using the system with patients that weigh more than maximum system capacity Using the system on patients who have ulcers at a more advanced stage than the one for which the system is meant for. Using the system on patients with illnesses or traumas which are incompatible with alternate functioning Risk: development of decubitus ulcers No recovery of present ulcers. Risk of deterioration of present ulcers and development of new ones Ineffectiveness of the system. No guarantee that ulcers will be prevented or cured Risk of mattress breakage and of development of decubitus ulcers No recovery of present ulcers and risk of deterioration of present ulcers and development of new ones Risk: worsening of the patient s general health conditions and of the specific illnesses and traumas. User Guide Euro Basic Rev 06 del 11/2011 pag. 5 di 16

6 Using or storing the system in the presence of flames or other elements which may catch fire Using the system on beds without bars or with bars that are too low Risk: damaging the system and its functionality The patient runs the risk of falling from the bed Using spare parts that are not original Modifying or tampering with the system without manufacturer s permission Risk: damaging the system and its functionality Non-observance of instructions in the manual 7. WARNINGS Keep system away from flames, heaters and protect from humidity Avoid any contact with flammable gasses and liquids. RISK OF EXPLOSION Before managing the compressor make sure that it is not power supplied Keep and use compressor in dry places Do not use the system in the presence of high electromagnetic fields. Electromagnetic interference can cause damage to the equipment and its malfunctioning. Use device only for the purposes for which it has been designed. Improper use can cause damage to people and things and the warranty will cease to be active. All repairing and maintenance have to be done by qualified staff. Otherwise the warranty will cease to be active. User Guide Euro Basic Rev 06 del 11/2011 pag. 6 di 16

7 8. CONTROL PANEL Leds and buttons: ON/OFF: switch on/ off STATIC/DYNAMIC When switched to STATIC means that static mode has been set When switched to DYNAMIC means that dynamic mode has been set ALARM: system is malfunctioning Comfort: shows the pressure range that has been manually set 9. INSTALLATION - Lay overlay - mattress onto the traditional mattress; air hoses must be at foot side. - Make sure that bed safety sides are high enough for the mattress so as to guarantee patient s safety conditions - Make sure that CPR valve near the head end is shut by pulling the bigger red block firmly without pushing the transparent flap and making sure not to extract the block - Pull out the handle at the back of the compressor and hang the compressor at the foot end of the bed or place it underneath the bed. Make sure that it has been clasped properly or that it is in a stable position. - Do not cover the compressor in order to avoid overheating. - Place the connectors of the three tubes in the sockets at the bottom of the compressor without obstructing them. The order with which tubes are placed is not important. Make sure that tubes are not kinked. - Plug the power cord into an electrical outlet at V AC, 50 Hz User Guide Euro Basic Rev 06 del 11/2011 pag. 7 di 16

8 10. STARTING THE COMPRESSOR - Turn on the compressor by pressing I/O. Make sure that the ON button is lightened. If it is not, look at the procedure described in the trouble-shooting section. - Until the overlay-mattress reaches minimum pre-established pressure, the ALARM led will stay on. Normally, this phase lasts minutes. - Switch to ON the STATIC button. - Turn the regulating pressure button at max, in order to obtain a faster inflation. - When the ALARM led switches off, it is possible to set the function (whether dynamic or static) and inflation regulation that at best suite patient s needs. 11. DYNAMIC AND STATIC MODE In dynamic mode, the compressor inflates two of three consecutive elements alternatively, apart from the three head elements which always remain static. The dynamic cycle is programmed to deflate one of three sections every three minutes, plus 1 minute when all three sections are at the same pressure. The cycle thus lasts 10 minutes. In static mode all elements have the same level of inflation and the same pressure. To switch from dynamic to static, turn ON the STATIC button 12. NURSING For nursing procedure or any situation requiring a hard mattress, we suggest to set the function on STATIC and turn the pressure regulation button to the maximum level. We advise not to use the system with the pressure regulated as above. When nursing procedures are terminated, switch to the dynamic function and set the pressure as per patient s needs. 13. INFLATION ADJUSTMENT In order to choose the best level of inflation, we suggest to use the following hand check procedure (approved by AHCPR - Agency for Health Care Policy and Research): User Guide Euro Basic Rev 06 del 11/2011 pag. 8 di 16

9 - open the side zip which fastens cover and inferior case - slide your hand in between inflatable elements underneath the patient s buttock. - Make sure that there are at least 2.5-4cm between patient s buttock and underlying base. - In case the above mentioned distance: - Increase if distance is less than 2.5 cm - Decrease if distance is more than 4 cm 14. ALARMS Inflation pressure of the mattress is constantly monitored by an internal pressure switch. If alarm activates (EXCLUSION MADE FOR INITIAL INFLATION) we recommend to follow this procedure in order to identify the cause: - check that tubes coming out of the compressor have been plugged in correctly - check that the inflatable elements of the mattress and the lateral distribution band are not broken. - Check that connection hoses are not kinked, twisted or entangled to the bed - check that inflatable elements are clicked into the clutches of the lateral distribution band If the alarm continues, please contact customer service without opening the compressor. Do not perform any action on the compressor. Maintenance has to be carried out only by authorised staff. 15. CPR FUNCTION Euro Basic overlay mattress is provided with a fast deflation function (CPR) in order to allow cardiopulmonary resuscitation to be performed on the patient. The CPR valves are located in the left-hand side of the head end of the mattress. In normal conditions, the CPR valve has to remain closed. To close it, click the three valves of the big red block into plugs present on the red band. Pull gently to verify that the block does not come out. If necessary, before performing CPR, open CPR valve to release air quickly from the mattress. To open it, firmly pull out the big red block, pressing on the transparent tongue. User Guide Euro Basic Rev 06 del 11/2011 pag. 9 di 16

10 PRESS AND PULL 16. CLEANING THE SYSTEM Cleaning the compressor How often: monthly What to do: clean with damp cloth and possibly add a disinfectant such as Sporicidin spray. DO NOT POUR LIQUIDS DIRECTLY ON THE MATTRESS Cleaning inflatable elements How often: after every change of patient or, in case of single patient use, every two months What to do: - clean with damp cloth and, if necessary, add delicate alcohol-free, bleach-free or chlorinefree disinfectant. - Machine wash: max temperature 60 C using delicate alcohol-free, bleach-free or chlorinefree disinfectant; tumble drying: max temperature 60 C - An example of cleaning: - pre-washing: 60 C, for 30 minutes, solution of 1% of Sanitrate or 75 ml of Montana detergent. - washing: 60 C, for 50 minutes, Trig solution at 5% - rinse - drying: at 60 C DO NOT USE DETERGENTS CONTAINING ALCOHOL, CHLORINE OR BLEACH. THEY COULD DAMAGE THE CHEMICAL STRUCTURE OF THE MATTRESS DO NOT USE ABRASIVE MATERIALS SUCH AS IRON BRUSHES, STEELWOOL, KNIFE BLADES OR OTHER SHARP OBJECTS DO NOT IRON Cleaning the cover User Guide Euro Basic Rev 06 del 11/2011 pag. 10 di 16

11 How often: twice a week and before every new patient. What to do: machine wash and dry. Maximum temperature in both cases 60 C. For daily cleaning we suggest you use a damp cloth and a soft detergent or disinfectant. DO NOT USE DETERGENTS CONTAINING CHLORINE OR BLEACH. DO NOT USE ABRASIVE MATERIALS SUCH AS IRON BRUSHES, STEELWOOL, KNIFE BLADES OR OTHER SHARP OBJECTS DO NOT IRON 17. FUSE REPLACEMENT TO REPLACE FUSE, UNPLUG CABLE TO AVOID ELECTRIC SHOCK Open the fuse holder located below electric socket on the bottom part of the compressor. With the aid of a screwdriver, extract blown fuse and replace it with a new one with the same electrical characteristics. Use only 5 mm, 250V delayed 500 ma fuses. 18. HANDLING AND STORAGE In order to handle and store system correctly, please keep original packaging. Avoid abrupt transportation and blows to the compressor, since its electrical and electromechanical components are very delicate. Keep the compressor in the following conditions: - environment temperature: 0 40 C - relative humidity: < 85% The product is delivered inside a cardboard box. This box is sealed with adhesive tape in perfect hygienic conditions. When you receive the product, make sure that it corresponds to your order and that it has not been damaged during transportation. User Guide Euro Basic Rev 06 del 11/2011 pag. 11 di 16

12 In case of any problems, keep packaging and contact the currier and EuroAusili within 48 hours. Without any specific agreement, goods will travel at customer s risk. 19. TROUBLE-SHOOTING PROBLEM POWER led does not turn on (the compressor is not working) The mattress does not inflate or only partially inflates ALARM led remains turned on When setting the compressor to the minimum, the alarm activates Patient sinks into the mattress without alarm going off or the mattress is too rigid POSSIBLE SOLUTION Check the cable, the plug and the socket; check compressor fuse. Check tubes, connections, the lateral distribution band; if the problem continues to exist, please contact maintenance service. Check tubes, connections, the lateral distribution band; if the problem continues to exist, please contact maintenance service. This setting is too low for patient s weight. Increase comfort level. Adjust comfort level as explained in the previous paragraph. 20. TECHNICAL CHARACTERISTICS System Euro Basic Type of mattress Overlay mattress Dimensions overlay mattress (inflated) 200 x 85 x 10,5 cm 200 x 85 x 15 cm (with the addiction of PU foam base) Inflatable elements Nylon-PU - depth: 10 cm Circular section Maximum patient weight (Kg) 150 Emergency deflation time (CPR) 10 seconds Inintial inflation time 25 minutes Cover Waterproof PES/PU, transpirant to water steam Compressor shock proof ABS enclosure 30 x 18 x 13,4 cm User Guide Euro Basic Rev 06 del 11/2011 pag. 12 di 16

13 Technical characteristics Certifications Warranty Supply: V AC 50 Hz Power absorbed: 8 W Fuse: 250V, T500mA, 5mm Electric protection: II Applied part: type B Medical device, class I, in conformity with 93/42/EEC Rule 2 years IMPORTANT: this system complies to safety standards CEI EN and CEI EN and to 93/42/CEE directive about medical devices. If the user finds that the system does not work properly, it works intermittently and it is near electrosurgical devices, the problem could be caused by electromagnetic interference. In this case move the source of interference away. IMPORTANT: the manufacturer will supply, upon purchaser s request, circuit patterns, list of components and the instructions that qualified staff may need in order to repair the compressor IMPORTANT, for qualified staff: before handling compressor, disconnect the power cord.. All maintenance must be undertaken by qualified staff only. Please contact your dealer in case of need. 21. WASTE DISPOSAL Waste disposal instructions according to directives 2002/95/CE, 2002/96/CE and 2003/108/CE concerning reduced use of dangerous substances in electrical and electronic devices and waste disposal: The crossed-out wheeled bin symbol indicates that the old product has to be disposed of separately from other waste. Correct disposal of such apparatus, will be taken care of by the manufacturer. When you want to dispose of waste material, please contact the dealer and follow the national rules concerning waste disposal. Correct waste disposal and recycling will help prevent potential negative consequences for the environment and human health. Incorrect unauthorised disposal will lead to fines according to local rules. User Guide Euro Basic Rev 06 del 11/2011 pag. 13 di 16

14 22. WARRANTY CONDITIONS 1. The 24-month warranty, which becomes effective on the date of purchase, covers any manufacturing problem, and it includes both the substitution of faulty spare parts, and maintenance costs, only if these conditions are followed: 2. The warranty is valid only if the product has been used correctly, following the instructions and if the compressor has not been opened and/or tampered with. 3. The manufacturer will decide whether to repair the fault or to substitute the faulty part with a new one. 4. The warranty does not cover: - faults deriving from incorrect installation or use - faults deriving from maintenance done by unauthorised personnel. - Parts that are subject to wear and tear: pump membranes, distributing valve. 5. After a period of about 5000 hours or 12 months that the product has been working, please contact your seller or dealer for maintenance of the compressor Use only original products. Substituting broken or worn out parts with low quality products or home-made products, may jeopardize the correct functioning of the system. This will also make warranty ineffective. User Guide Euro Basic Rev 06 del 11/2011 pag. 14 di 16

15 User Guide Euro Basic Rev 06 del 11/2011 pag. 15 di 16

16 Made by rev 06-11/2011 User Guide Euro Basic Rev 06 del 11/2011 pag. 16 di 16

Med Aire Alternating Pressure Pump and Pad System

Med Aire Alternating Pressure Pump and Pad System User Manual Med Aire Alternating Pressure Pump and Pad System 14002E 14001E Symbols & Statements NOTE Indicates some tips or some information users should be aware of. CAUTION Indicates correct operating

More information

Instruction Manual for Configura Cushionair Portable Pump

Instruction Manual for Configura Cushionair Portable Pump Instruction Manual for Configura Cushionair Portable Pump Fitted with battery powered pump, suitable for Configura Portable chairs V E R S I O N O N E M A Y 2 0 1 6 Contents Introduction 3 Set up of Cushionair

More information

Air Plus User Manual

Air Plus User Manual Air Plus User Manual Alternating pressure mattress for prophylaxis and treatment of pressure sores Indications for use The Air Plus has been developed as a state of the art pressure relieving system for

More information

Paradise Pump Series Operator s Manual

Paradise Pump Series Operator s Manual Paradise Pump Series Operator s Manual P/N 12421-000 9/05 Paradise Pump Operator s Manual Important Before using the Paradise Pump Alternating Pressure Relief Systems, please read and understand this

More information

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc. Diamond 8 Plus Alternating + Micro Low Air Loss Pressure Relief System User Manual Distributed by: Quart Healthcare Inc. www.quarthealthcare.com Warning Connect the Master Control unit to a proper power

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax: Operation Manual H & R Healthcare 1750 Oak Street Lakewood, NJ 08701 Phone: 800-801-5533 Fax: 732-367-6231 www.handrhealthcare.com Congratulations and thank you for purchasing this Relief Aire Alternating

More information

Alternating Pressure / Low Air Loss Mattress System

Alternating Pressure / Low Air Loss Mattress System 750000 Alternating Pressure / Low Air Loss Mattress System User Manual Important: Do not operate the Mattress System without first reading and understanding this manual! Save this manual for future use.

More information

User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions

User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions User Manual soft air simplex wds Art. No. 110 470-wds Pressure ulcer prevention and treatment-system Assembly and Operation instructions Health. Security. Independence. List of contents 1 Foreword Seite

More information

SC505 Sof Care Inflator. Operating Instructions and Service Manual

SC505 Sof Care Inflator. Operating Instructions and Service Manual SC505 Sof Care Inflator Gaymar Industries, Inc. 10 Centre Drive Orchard Park, NY 14127 Toll Free +1 800.828.7341 + 1 716.662.2551 Fax +1 800.993.7890 Outside USA +1 716.662.8636 Outside USA Fax +1 716.662.0730

More information

User Manual soft air wds

User Manual soft air wds User Manual soft air wds Item. No. 110 400-wds soft air cumulus wds Item. No. 110 400-cu-wds Pressure ulcer prevention and treatment-systems Assembly and Operation instructions Health. Safety. Independence.

More information

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please

More information

User Manual DIRECTHEALTHCARESERVICES.CO.UK

User Manual DIRECTHEALTHCARESERVICES.CO.UK User Manual DYNA-FORM MERCURY ADVANCE The Dyna-Form Mercury Advance mattress is a High / Very High Risk dynamic replacement system, combined with the benefits of modern foam technology. Offering high levels

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

Pegasus Aircare Mattress Overlay System Models 2200 and 2201 Pegasus Aircare Mattress Overlay System Models 2200 and 2201 User Guide LFT11099 Issue 3 PEGASUS AIRCARE Mattress Overlay System Models 2200 and 2201 The PEGASUS AIRCARE Overlay system provides optimum

More information

12V MINI AIR COMPRESSOR

12V MINI AIR COMPRESSOR 12V MINI AIR COMPRESSOR STOCK No.65958 PART No.DA12/250A INSTRUCTIONS IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL. 08/2001 GENERAL INFORMATION

More information

User Manual DIRECTHEALTHCARESERVICES.CO.UK

User Manual DIRECTHEALTHCARESERVICES.CO.UK User Manual DYNA-FORM MERCURY ADVANCE The Dyna-Form Mercury Advance is a pressure relieving mattress suitable for use with patients at VERY HIGH RISK of pressure ulcer damage. Offering high levels of patient

More information

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315 PORTABLE WORK LIGHT MODEL NO: CL6FS PART NO: 4003530 OPERATION INSTRUCTIONS GC0315 INTRODUCTION Thank you for purchasing this CLARKE Worklight. Before attempting to use this product, please read this manual

More information

DYNAMIC COMPRESSION THERAPY

DYNAMIC COMPRESSION THERAPY PULSE PRESS DYNAMIC COMPRESSION THERAPY MULTITEC 12 User Manual May 2011 0120 CONTENTS:- SAFETY INSTRUCTIONS ELECTROMAGNETIC INTERFERENCE DESCRIPTION OF CONTROLS MODE SELECTION OPERATING INSTRUCTIONS CARE

More information

12V Mini Air Compressor

12V Mini Air Compressor INSTRUCTIONS FOR 12V Mini Air Compressor Stock No.80999 Part No.DA12/250B IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION This

More information

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 Made For: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia WARNING: FAILURE TO FOLLOW OPERATING, SAFETY AND MAINTENANCE

More information

SALISBURY ACTIVE OVERLAY SYSTEM

SALISBURY ACTIVE OVERLAY SYSTEM General User/ Safety Guide SALISBURY ACTIVE OVERLAY SYSTEM ACTIVE MATTRESSES www.harvesthealthcare.co.uk 1 2 CONTENTS WARNINGS & CAUTIONS GENERAL INFORMATION 1 DEFINITION OF THE GROUPS MENTIONED 2 NON-COMPLIANT

More information

User Manual DIRECTHEALTHCARESERVICES.CO.UK

User Manual DIRECTHEALTHCARESERVICES.CO.UK User Manual DYNA-FORM MERCURY ADVANCE 2 USER MANUAL The Dyna-Form Mercury Advance is a pressure relieving mattress suitable for use with patients at VERY HIGH RISK of pressure ulcer damage. Offering high

More information

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System AltaDyne XT Model 773400A AltaDyne XD Model 774200A Alternating Pressure / Low Air Loss Replacement Mattress System USER MANUAL Important: Do not operate the Mattress System without first reading and understanding

More information

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2 VENTI-O 2 plus O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2 Device description and operating instructions Overview VENTI-O 2 plus with therapy

More information

200L BELT DRIVEN AIR COMPRESSOR

200L BELT DRIVEN AIR COMPRESSOR 200L BELT DRIVEN AIR COMPRESSOR MODEL NO: BOXER 14/200 PART NO: 2245215 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 ISS 4 INTRODUCTION Thank you for purchasing this CLARKE 200L Belt

More information

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems 10. Dimensions and Ordering Codes Integrity Alternating Pressure Mattress System Integrity Mattress Specification: Standard Extra Long Extra Narrow HD Dimension approx LxWxH (cm): 196x86x15 220x86x15 216x79x15

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual ORB-400 BUBBLE/HAZE MACHINE Item ref: 160.462UK User Manual Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty Introduction Thank you for

More information

Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers AME PressureGuard APM² The PressureGuard APM² enables you to change instantly and easily from alternating pressure to basic lateral rotation with a single, recessed toggle switch. The silent, reliable,

More information

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no Model no. 009-0- V DIRECT DRIVE MULTI-FUNCTION AIR COMPRESSOR IMPORTANT: Questions, problems, missing parts or for technical service? Before returning to your retailer, call our customer service department

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

INSTALLATION GUIDE Gas Rangetops

INSTALLATION GUIDE Gas Rangetops INSTALLATION GUIDE Gas Rangetops Contents Wolf Gas Rangetops........................... 3 Safety Instructions............................ 4 Gas Rangetop Specifications.................... 5 Gas Rangetop

More information

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on) by Supera Anesthesia Innovations USER'S GUIDE OC4000 OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY I O : ON (power switched on) : OFF (power switched off) : Class II protection : Do not expose to open flames

More information

Bath Buddy / Bathmate Instruction Book

Bath Buddy / Bathmate Instruction Book Bath Buddy / Bathmate Instruction Book Thank you for purchasing the Bath Buddy / Bathmate portable bath lift. This simple bathing aid is designed The Bath Buddy/Bathmate is all that s needed to gently

More information

COMPACT AIR COMPRESSOR MODEL NO OWNER S MANUAL

COMPACT AIR COMPRESSOR MODEL NO OWNER S MANUAL COMPACT AIR COMPRESSOR MODEL NO. 299-2642-0 OWNER S MANUAL IMPORTANT: If you have questions or problems, are missing parts or require technical service, before returning to your retailer, please call our

More information

User manual. ZX trolley.

User manual. ZX trolley. User manual. ZX trolley. Date July 2011 02 User manual. ZX trolley. ZX trolley. Safe transportation for medical gas cylinders. Important Please read this manual carefully before attempting to use the BOC

More information

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF. APH166 Morpheus Air USER MANUAL Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF. Tel: (01924) 614567 l Fax: (01924) 607480 Issue 1-11/03/2016 IMPORTANT SAFEGUARDS

More information

e.do Gripper Safety requirements, technical features and assembly and integration instructions

e.do Gripper Safety requirements, technical features and assembly and integration instructions e.do Gripper Safety requirements, technical features and assembly and integration instructions Requirements, technical features and instructions for safe installation and use of the e.do Gripper. CR00758190-en_00/2018.05

More information

Use this key to determine which sections of this Product Manual apply to your job.

Use this key to determine which sections of this Product Manual apply to your job. R710 Product Manual Contents Warnings and Important Information 3 Recommended Use 4 Product Information 5 Technical Data 5 Before & During Every Transfer 6 Inspection 6 SoloLift Scale (optional) 6 SoloVest

More information

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection Model no. 009-5032-6 TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection IMPORTANT: Questions, problems, missing parts or for technical service? Before returning to your retailer, call our customer

More information

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913 24L AIR COMPRESSOR MODEL NO: RANGER 7/240 PART NO: 2242000 OPERATION & MAINTENANCE INSTRUCTIONS LS0913 INTRODUCTION Thank you for purchasing this CLARKE 24L Air Compressor. Please read this manual fully

More information

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified USER MANUAL Model: PM4300 Series (PM4351 Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton,

More information

Vapotherm Q50 Compressor. Instructions for Use

Vapotherm Q50 Compressor. Instructions for Use Vapotherm Q50 Compressor Instructions for Use Contents Quick Start Guide...2 Intended Use...3 Indications, Warnings and Cautions...4 Primary Indications...4 Contraindications...4 Warnings and Cautions...4

More information

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic TIMER (MIN) POWERPRESS UNIT 40 70 40 80 90 10 60 100 MIN MAX PRESSURE (mmhg) User Manual Neomedic 9601 Owens mouth Ave. #8 Chatsworth, CA 91311 Toll Free: 866-990-1168 Tel: 818-998-1023 Fax: 818-998-0277

More information

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115 AIR COMPRESSOR MODEL NO: CHAMP 3 PART NO: 2225222 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Air Compressor. Please read this manual fully before use

More information

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: 2244030 OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product,

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

50L BELT DRIVEN AIR COMPRESSOR

50L BELT DRIVEN AIR COMPRESSOR 50L BELT DRIVEN AIR COMPRESSOR MODEL NO: BOXER 14/50P PART NO: 2245200, 2245203 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 - ISS 4 INTRODUCTION Thank you for purchasing this CLARKE

More information

DECLARATION OF CE CONFORMITY DECLARATION OF CE CONFORMITY

DECLARATION OF CE CONFORMITY DECLARATION OF CE CONFORMITY DECLARATION OF CE CONFORMITY The manufacturer: FARO S.p.A. Via Faro, 15 20060 Ornago (Milano) ITALY declares under its own responsability that following product: Product name: Dental Practice Micromotor

More information

SILENTAIRE TECHNOLOGY

SILENTAIRE TECHNOLOGY SILENTAIRE TECHNOLOGY General User and Maintenance Instructions Thank you and congratulations on the purchase of your PANTHER, the leader in the industry of portable air compressors. The PANTHER is built

More information

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS U S E R M A N U A L Model: PM4300 Series (PM4351 Shown) SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090

More information

Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H

Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H Product instruction manual Easymount Sign Laminators EM-S1400C, EM-S1600C, EM-S1400H, EM-S1600H The Easymount Sign has been designed to be user friendly, however we strongly recommend you take a few minutes

More information

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on) OXYGEN CONCENTRATORS USER'S GUIDE OC4000 OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY I O : ON (power switched on) : OFF (power switched off) : Class II protection : Do not expose to open flames GLOSSARY

More information

Leglifter. user instructions. Simple solutions for everyday independence

Leglifter. user instructions. Simple solutions for everyday independence user instructions Simple solutions for everyday independence The by Mangar International enables people to raise their legs onto the bed independently or with minimal assistance. Power is provided by the

More information

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website: USER MANUAL Model: PM4300 Series SAVE THESE INSTRUCTIONS For the most current manual revision, please visit our Website: www.precisionmedical.com 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA

More information

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP USER MANUEL AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP TIRE EQUIPMENT MANUFACTURER 1.866.409.RACK WWW.MARTINSINDUSTRIES.COM info@martinsindustries.com PARTS Verify that the following components

More information

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION IFU SBPMON107 CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE BATTERY INSTALLATION CORRECT POSITION FOR MEASUREMENT POSITIONING THE CUFF

More information

Regalia Oxygen Concentrator

Regalia Oxygen Concentrator Regalia Oxygen Concentrator REGALIA INSTRUCTION MANUAL P/N 5167 Rev B January 2014 Table of Contents Warnings and Cautions... 3 Indications for Use... 4 Introduction... 4 Important Safety Instructions...

More information

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: 2244025 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

AS/NZS 1801 USE AND CARE BOOKLET OCCUPATIONAL PROTECTIVE HELMET

AS/NZS 1801 USE AND CARE BOOKLET OCCUPATIONAL PROTECTIVE HELMET AS/NZS 1801 USE AND CARE BOOKLET OCCUPATIONAL PROTECTIVE HELMET 2 EN DANGER! intended use of this helmet involves activities that are extremely dangerous. FAILURE TO HEED AND FOLLOW THESE INSTRUCTIONS

More information

4WD ACCESSORIES BONUS CARRY BAG 100L AIR COMPRESSOR INSTRUCTION MANUAL

4WD ACCESSORIES BONUS CARRY BAG 100L AIR COMPRESSOR INSTRUCTION MANUAL 4WD ACCESSORIES BONUS CARRY BAG 100L AIR COMPRESSOR INSTRUCTION MANUAL Contents Page WARRANTY DETAILS... 3 REPAIR AND REFURBISHED GOODS OR PARTS NOTICE... 3 WELCOME... 4 INTENDED USE... 5 CONTENTS... 5

More information

Lateral Turning System. User Guide.

Lateral Turning System. User Guide. Lateral Turning System User Guide www.frontier-group.co.uk Key This user guide contains important information on correct usage, handling, cleaning and decontamination. Please read carefully prior to use.!

More information

Dynamic pressure system for pressure relief

Dynamic pressure system for pressure relief Dynamic pressure system for pressure relief Foreword/Content Optimal use of the right products. In this issue you will find an overview of our core assortment of dynamic alternating pressure relief systems

More information

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

D10S/D20S Wall/Post Mount Inflator Quick Start Manual PART NUMBER SERIAL NUMBER D10S/D20S Wall/Post Mount Inflator Quick Start Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product

More information

User manual STARLOCK. Careways International - Innovation Quality Performance

User manual STARLOCK. Careways International - Innovation Quality Performance EN User manual LOCK Careways International - Innovation Quality Performance Content About this manual... 3 The Starlock cushion... 4 1 Warnings... 5 2 Important parts... 6 3 Use... 8 3.1 The right amount

More information

03/07/2014 V

03/07/2014 V 03/07/2014 V1-03072014 General safety This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge

More information

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual MODEL 50012 Maverick Heavy Duty Aerosol Compressor Operator s Manual This page left blank intentionally CONTENTS Page No. INSPECTION... 1 GENERAL INFORMATION... 1 SAFETY PRECAUTIONS... 2 BASIC OPERATING

More information

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO: 1499490 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0918 - ISS 2 INTRODUCTION Before attempting to use this product, please read this

More information

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT: Flat Fold Highchair INSTRUCTION MANUAL Designed and manufactured to BS EN 14988: 2012 IMPORTANT: Thank you for choosing our product. Please read and understand these instructions before using this flat

More information

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512 COMPRESSOR MODEL NO: WARRIOR 55 PART NO: (110V) 2323010, (230V) 2322020, OPERATION & MAINTENANCE INSTRUCTIONS LS0512 INTRODUCTION Thank you for purchasing this CLARKE Compressor. Before attempting to use

More information

NIMBUS range. with people in mind

NIMBUS range. with people in mind NIMBUS range Advanced Mattress Replacement systems with people in mind OPTIMUM PRESSURE RELIEF AND COMFORT In clinical use for more than 20 years, Nimbus Alternating Mattress Replacement Systems have consistently

More information

KERN EG/EW Version /02

KERN EG/EW Version /02 E KERN EG/EW Version 1.5 07/02 Operating Instructions Electronic Precision Balances Contents 1 TECHNICAL DATA... 20 2 UNPACKING AND STANDARD ACCESSORIES... 23 3 SETTING UP THE BALANCE... 23 4 EXTERNAL

More information

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual.

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual. Panacea AIR PRO MATTRESS Owner s Manual Please keep and refer to this Owner s Manual. Thank you for purchasing a Panacea Air Pro Mattress from Direct Supply Equipment & Furnishings. Please read this entire

More information

Dual Release Walkers 6291 Series. 1 General. 1 Dual Release Walkers. 1.1 Symbols WARNING

Dual Release Walkers 6291 Series. 1 General. 1 Dual Release Walkers. 1.1 Symbols WARNING User Manual DEALER: This manual MUST be given to the user of the product. USER: BEFORE using this product, read this manual and save for future reference. Dual Release Walkers 6291 Series EN User Manual...page

More information

MA90 Series Mattresses. MA95 Series Mattresses

MA90 Series Mattresses. MA95 Series Mattresses Owner s Operator and Maintenance Manual MA90 Series Mattresses MA90Z Lateral Rotation with Alternating Pressure and On-Demand Low Air Loss System MA90ZB42 Lateral Rotation with Alternating Pressure and

More information

PPS PORTABLE POWER SUPPLY

PPS PORTABLE POWER SUPPLY PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety

More information

Instructions for use Compressed air injector with water trap

Instructions for use Compressed air injector with water trap Instructions for use Compressed air injector with water trap Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for Cleaning and Care 3.1 Disassembling

More information

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B

INFLATION STATION. Cordless OWNER S MANUAL MODEL NO: RCP-C65B [ACT 050] Manual E 4/4/06 4:34 PM Page 1 Cordless INFLATION STATION OWNER S MANUAL MODEL NO: RCP-C65B KEEP THE ORIGINAL BOX, PACKAGING AND RECEIPT. BEFORE OPERATING THIS UNIT, READ THE MANUAL THOROUGHLY

More information

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: 2244010 OPERATION & MAINTENANCE INSTRUCTIONS LS01/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product, please

More information

LOGIC RANGE AUTOMATIC PRESSURE

LOGIC RANGE AUTOMATIC PRESSURE LOGIC RANGE AUTOMATIC PRESSURE REDISTRIBUTING Systems with people in mind Mattress Replacement & Overlay Systems The Auto logic 200 mattress replacement and Auto logic 110 overlay systems are part of the

More information

Code AWC20HP Air Compressor

Code AWC20HP Air Compressor Code 951816 AWC20HP Air Compressor Index of Contents Index of Contents 02 Declaration of Conformity 02 What s Included 03 Safety Precautions 03 Specifications (AWC20HP Air Compressor) 04 Assembly Instructions

More information

User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700

User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700 User manual PG132 Rev01 Editi 220114 Compressive Limbs Therapy System DVT-7700 I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it http://www.itechmedicaldivision.com

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

Intermittent Pneumatic Compression System

Intermittent Pneumatic Compression System User Manual Intermittent Pneumatic Compression System To ensure safe use of this device, it is essential that you read and fully understand the information contained within this manual. Mechanical prophylaxis

More information

Operation Manual Airbrush Compressor AS196A ARTICLE 34207

Operation Manual Airbrush Compressor AS196A ARTICLE 34207 Operation Manual Airbrush Compressor AS196A ARTICLE 34207 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments,

More information

EC DECLARATION OF CONFORMITY

EC DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY 14 24L OIL FREE AIR COMPRESSOR IM201-24L Always Read Instruction Manual Retain for Future Reference CERTIFICATE OF GUARANTEE This product is guaranteed for a period of 1 Year,

More information

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR MODEL NUMBER: 30033-300P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.

More information

COMPRESSOR AND INFLATOR WITH TORCH

COMPRESSOR AND INFLATOR WITH TORCH WHAT S IN THE BOX COMPRESSOR AND INFLATOR WITH TORCH 12V INSTRUCTION MANUAL SPECIFICATIONS Voltage: 12V Max Current: 10Amp Max Pressure: 150psi (10.3bar) Max Flow Rate: 16l/min Weight: 1.21kg ozito.com.au

More information

SILENTAIRE TECHNOLOGY

SILENTAIRE TECHNOLOGY SILENTAIRE TECHNOLOGY 8614 Veterans Memorial. Houston, Texas 77088 832/327-7452 800/972-7668 Fax: 832/327-0668 E-mail: silentaire@silentaire.com Thank you and congratulations on the purchase of your OILLESS

More information

NovelBright LED Illuminator

NovelBright LED Illuminator NovelBright LED Illuminator Instruction Manual version NS01_11 Instruction Manual This LED illuminator is suitable for research use only. It must be used by specialized personnel that know the health risks

More information

Technical information. 700 version software. 500 version software. 700 IFI version software. 500 IFI version software. User manual

Technical information. 700 version software. 500 version software. 700 IFI version software. 500 IFI version software. User manual BIKE Technical information 700 version software 500 version software 700 IFI version software 500 IFI version software User manual Contents Manufacturer and equipment identification... 3 Description of

More information

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium User manual MNPG 102 Rev. 04 Edition 04/02/16 Pressotherapy model Power-Q1000 Premium I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it

More information

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for

More information

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury. 2 GALLON AIR COMPRESSOR Model: 7517 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR S S F U SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR MACHINERY DIVISION OWNER S MANUAL UNIT INSTRUCTIONS Please follow all SSFU Safety Instructions. Contact your Duro Dyne Tech Service if you have

More information

EXCITE. Synchro. User manual

EXCITE. Synchro. User manual EXCITE Synchro User manual Contents Manufacturer and equipment identification... 3 Description of the equipment... 5 Technical data... 15 Accessories... 18 Safety devices and notices... 19 Place of installation...

More information

Portable oxygen concentrator

Portable oxygen concentrator Table of contents G3 1. Introduction 2 2. Important Safety Rules 3 3. Unpack your Lovego 4 4. User Controls & System Status Indicators 5 5. Quick Start 6 6. How to operate 7 7. How to operate with battery

More information

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT 1 METRON MANIPULATION TABLES - WARRANTY STATEMENT Metron Medical Australia Pty Ltd. will warrant this table, for parts only against defects in manufacture for a period of two (2) years for structural integrity,

More information