Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Size: px
Start display at page:

Download "Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION"

Transcription

1 Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area. The system is designed as a portable unit and can sit on any stable and dry platform. The water supply inlet is a 1" Female Pipe Thread connection. Your supply to the system should be able to supply a minimum of 20 gallons per minute of clean filtered water at a line pressure of at least 40 psi. Most city water pressure systems will be capable of supplying a sufficient volume and pressure but be sure that the line that is running from your source to the system is large enough to maintain a constant water pressure during operation of the unit. Blue River Technologies recommends a minimum water supply line of 1" Inside Diameter with a constant water pressure of 50 psi. ( When the system turns on the pressure drop at the discharge point should be from 10 to 20 psi.) Polymer Supply The Blue River Technologies Port-A-Poly mixer can be set up to accept the emulsion polymer from either totes, 55 gallon drums, or 5 gallon pails. Suction tubes for both the 5 and 55 gallon supplies are furnished with your unit. Attach the correct suction tube to the hose with the clamp provided.

2 Tote, Drum or Pail Supply When utilizing the system with a 55 gallon drum or tote supply source, locate the drum or tote as close to the system as possible. It is obviously best to have your tote or drum elevated to provide a flooded suction to the pump. If this is not practical, locating the drum close to the unit will normally be sufficient. Feeding your polymer from the drum (with the drum in a horizontal position) or a tote requires a shutoff valve and suitable strainer at the source and also the drum or tote will need to be vented during operation of the unit. Utilize a feed line of 3/8 or 1/2" I.D. and make sure that it is suitable for suction line. That means the you should use braided hose or semi rigid polyethylene tubing for your supply line. The suction of the pump may collapse non braided pvc tubing. Hook up the supply line to the barb fitting located at the back of the unit. (If the optional calibration column and valve is installed, make sure the valve is in the closed position.) When using the drum in a vertical position or feeding polymer from a 5 gallon pail it is best to use a semi rigid polyethylene, translucent tubing for your feed line. The feed line should go down to near the bottom of the container but make sure that it remains slightly off the bottom to avoid clogging. This line should have an I.D. of at least 3/8". Flow Regulator Your unit includes a water flow regulator on the primary water line. This device will regulate the water flowing thru the primary mixer to a specific flow rate. These valves are available in 5 gpm, 10 gpm, 12 gpm and 15 gpm flow rates. Your unit has been built for a specific flow rate. The flow regulator should be sized to match the mixer nozzle that was shipped with the unit. REGULATOR SOLENOID VALVE FLOWMETER ADJUSTMENT Water Solenoid Valve Your unit includes a water solenoid valve. This valve opens whenever the run switch is activated. When the run switch is returned to the off position this valve will remain open for a short period of time to flush out the line. Inside the control box is a timer relay that can be set from 3 to 60 seconds. This relay will hold your water solenoid valve open after the switch is returned to "OFF" for the number of seconds that is set on the dial. (Factory set at 60 seconds) To change the timer simple rotate the dial to the number of seconds that is desired. Never remove the cover to the control box when the unit is plugged in. Dilution Water Flow Meter The water dilution line is regulated with a 0-20gpm water flow meter. This flow meter is adjusted with the valve located at the bottom of the column. If no secondary water flow is desired this valve should be closed completely. As secondary dilution flow is needed, open up the valve to the desired flow rate. When the run switch is turned on the water solenoid valve will open up. Water will flow thru the primary line at the rate controlled by the water flow regulator. Additional water can be sent to the secondary static mixer by opening up the adjustment valve on the Dilution Water Flow Meter. After making an adjustment to this valve insure that the reading on the pressure gage is at least 10 psi. If it falls below 10 psi you will need more water supply pressure to run the unit at the new setting.

3 Pressure Gage The pressure gage shipped with your unit is a 0-30 psi liquid filled gage. The gage gives the operator a visual indication that the unit is operating normally. Normal operating range is between 10 and 20 psi. Observe the gage during the initial set up and operation of the unit. A substantial change in pressure will indicate insufficient water flow, plugged solution line or other problem with the system. Your flow regulator should keep this pressure in the correct range. If the gage reads low check to insure sufficient line pressure. Mixing Tee and Check Valve Polymer is injected into the mixing tee thru a stainless steel check valve. This check valve insures that water does not back flow into the diaphragm pump during operation. If water would back flow into the polymer line or pump it will cause the polymer to coagulate and plug up the line or pump. If this valve sticks open for any reason the unit must be shut down and the check valve cleaned with mineral oil and inspected to insure that it is operating. Primary Mixing Chamber The Port-A-Poly polymer mixer utilizes a Blue River Technologies Hydro-Mixer as a primary mixing device. This mixer has a nozzle that has holes sized for the desired flow rate. Changes to the nozzle affects the mixing energy of the unit. For example if the holes are enlarged the mixing energy is reduced. As the hole size is reduced or if the flow rate of water thru the mixer is increased the mixing energy increases. If more energy is desired you can increase the size of the flow regulator thus increasing the mixing energy. Likewise a reduction in flow rate will decrease the mixing energy. Blue River Technologies can furnish nozzles with smaller or larger nozzle holes if additional mixing energy is desired.

4 Secondary Water Dilution Line The secondary water dilution line is used to provide additional dilution water to aid in mixing the flocculant with the sludge. Your system is built with the capability of adding an additional 15 gpm of water to the solution. This water is fed into the system behind the primary mixing head and directly in front of the secondary static mixer located on the right hand side of the unit. After the dilution water leaves the top of the dilution water flow meter it flows thru a 1/2 diameter braided pvc line over to the opposite side of the unit. Secondary Static Mixer A secondary static mixer is located on the side of the unit near the discharge port. This mixer is designed to provide a final turbulent mixing zone to cause the dilution water and the flocculant solution to completely emulsify prior to being injected into the sludge line. The inline static mixer should be flushed out at the end of the cycle before the unit is shut down for an extended period. The timer on the control should allow this mixer to be completely flushed out before the water is shut off. If polymer should build up inside this mixer you should be able to see it thru the clear pvc chamber. Flush the system with clean water to clean out the mixer. Secondary Static Mixer Check Valve Water Dilution Line Check Valve A check valve is installed in front of the Secondary Static Mixer to prevent polymer solution from flowing back into the secondary water dilution line and flow meter. This ball type check valve is easily taken apart and cleaned if necessary. Unscrew the unions located at the top and bottom of the check valve. Remove the center section and clean the ball and seat area with a clean dry rag. Reinstall the valve with the flow direction arrow pointing up.

5 Diaphragm Pump Operation Your unit includes a high viscosity diaphragm metering pump. This unit is fully described in the pump manual section of this booklet. You should read through this section prior to operation of your unit. The pump includes two ways to adjust the output of the pump. Stroke Length Adjustment: The stroke adjustment knob located on the front of the pump changes the output of each stroke of the pump. This adjustment should never be turned below the 10% set point. This adjustment should always be made with the pump running. Frequency Adjustment: The frequency adjustment is done from the front of the panel. The LMI B921-85H pump has a maximum output of 2.5 gallons per hour. To reduce or increase the output of the pump with the stroke frequency adjustment use the arrow keys on the right side of the control panel to adjust the stroke frequency up or down. This adjustment will change the stroke rate from a low of 0 to a high of 100 strokes per minute. This will alter the output of the pump from 0 to a maximum of 2.5 gallons per hour depending on the position of the Stroke length adjustment dial. Remote Speed Adjustment Your pump may include a 4-20 ma speed adjustment option. Consult the manual on how to install and operate this option.

6 Primer Port A primer port and valve is included directly above the pump. A 60mL syringe was included with your Port-A- Poly mixer. After hooking up the polymer supply you will need to assist the pump to pull up the high viscosity emulsion polymer up through the feed lines and into the pumping chamber for the start up of the pump. (This is also required should you let your pump run dry during normal operation) A plastic drip cover is included with the unit. Leave this drip cover over the pump at all times except when changing the frequency of the pump. To use the primer port, remove the cap from the valve. Remove the cover from the syringe tip and place the tip into the opening of the primer valve. Open the valve by turning the lever and draw out on the syringe. Close the valve and return the syringe plunger to the full closed position, open the valve and repeat the process until you can draw a small amount of polymer into the syringe. You will hear the pump change tone as it draws chemical into the diaphragm chamber. You may need to repeat this process to expel all of the air out of your polymer supply line. This is normal when setting up a new drum or container of polymer. You can minimize the requirement for priming the unit by keeping lines full during the switching out of containers of polymer. Optional Calibration Column An optional calibration column is available for the Blue River Technologies Port-A-Poly unit. This column includes a ball valves and fittings and can be installed in the pump suction port located at the back of the pump. This column can be used to precisely set the output of the pump to a desired flow rate. The column is marked for a timed rate of 1 minute. To calibrate your pump, fill the column with chemical up to the high level mark "0". Make sure the valve located at the back of the Port-A-Poly (the supply line valve) is closed. Turn the pump on and run the pump for a period of 1 minute. Observe the reading on the right side of the column.

7 Initial Startup Port A Poly is plumbed up to a 1 water supply line that can maintain a minimum of 40psi water pressure with 30 gpm flowrate. Unit should be wired into a 110VAC 1ph electrical outlet with Ground Fault Protection. 1. Turn on Power with the OFF ON Switch located on the left hand side of the control box. Red LED should illuminate. 2. Insure that the water supply line valve is in the on position. 3. Insure that the secondary dilution line valve is in the closed position. 4. Turn on the unit with the Run switch located on the right hand side of the control box. Green LED should illuminate, water valve should open and water will begin to flow thru the primary mixer. The LMI pump should turn on begin to pump polymer. (If you do not want to prime the pump or pump polymer at this time, push the start/stop button located on the right hand side of the pump face.) 5. For initial start up or if you have changed out your polymer supply you may need to prime the LMI Diaphram pump. Use the primer port located above the pump and the plastic syringe furnished with your unit to prime the LMI pump. ( If you turned off the LMI you will need to restart the pump with the start/stop button located on the right hand side of the pump face. 6. After priming the pump adjust the stroke length to the desired setting by turning the adjustment knob up or down. 7. Adjust the stroke frequency to the desired setting by using the up or down arrow keys located on the pump face. 8. If a secondary water dilution is to be used, open up the water dilution valve located at the bottom of the flow meter. Observe the pressure reading on the pressure gage. It should not fall below 10psi after the correct gpm on the water dilution line is set. 9. At the completion of the run cycle turn the unit off with the Run switch. The LMI pump will shut off, the water will continue to run for 60 seconds to flush out the line. (If you anticipate using the unit again in a short period of time you can turn off the unit with the On Off switch and the purge cycle will not take place.

ACCU-MIX 1200 / / 26270

ACCU-MIX 1200 / / 26270 ACCU-MIX 1200 / 14100 / 26270 Model 102006 (1200) Model 102002 (14100) Model 102003 (26270) Pre filter is required when the water supply is from a in house un filtered well to retain the warranty. Pre

More information

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware 57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water

More information

Flow Material Length. Weight GPM LPM. Style 3095

Flow Material Length. Weight GPM LPM. Style 3095 Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index Section 3000 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR...36 Versatile type of lubrication able to feed liquid to elevated, distant or inaccessible points. CONVEYOR CHAIN LUBRICATION SCHEMATIC...39

More information

Installation of Your SprayMaster System

Installation of Your SprayMaster System Installation of Your SprayMaster System 1. At the installation site, remove all equipment from the corrugated box and the polyethylene drum and replace the drum lid. Check the picture to identify each

More information

User Manual for the Mars Calibration Bench

User Manual for the Mars Calibration Bench User Manual for the Mars Calibration Bench Fall 2013 Table of Contents Table of Contents Table of Contents... iii Introduction... v Chapter 1: The Mars Calibration Bench... 1 What Is the Mars Calibration

More information

Pneumatic Powered - Plunger Pumps

Pneumatic Powered - Plunger Pumps Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions

More information

553 Series.

553 Series. 38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Tank Distribution System A-UPT Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.2 Warnings and Cautions... 1 1.2 Theory of Operation...

More information

PRO SINK -R 1 and 2. Dilution system CONTENTS

PRO SINK -R 1 and 2. Dilution system CONTENTS PRO SINK -R 1 and 2 Dilution system CONTENTS 1.0 Product description 2 2.0 Warnings.. 3 3.0 Installation procedure 4 4.0 Plumbing connections 4 5.0 Technical features.. 5 6.0 Maintenance... 6 7.0 Troubleshooting......6

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

Valves. Controllers. Valves Two Types

Valves. Controllers. Valves Two Types Hydraulics Taking the Irritation out of Irrigation My plants are getting irrigated, so I m all set, right? Marcus Duck Academic Advisor, Instructor & Program Coordinator MSU s 2-year Horticulture Programs

More information

VOLUMATIC WATER REGULATOR

VOLUMATIC WATER REGULATOR VOLUMATIC WATER REGULATOR For Cage Systems - PDS and Manual Adjustment Part Number 00-, 00-, 00- Introduction The Chore-Time VOLUMATIC Water Regulator is designed to regulate the water pressure for the

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

VOLUMATIC WATER REGULATOR

VOLUMATIC WATER REGULATOR Introduction The Chore-Time VOLUMATIC regulator is designed to regulate water pressure for Chore-Time Layer and Brood Grow Nipple Watering Systems. There is a model for manual adjustment of the regulator

More information

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS TM INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL TANK SYSTEMS When the HI-FLO Metering Head is attached to a tank, the tank will be pressurized to the same pressure as the irrigation system. Before

More information

TEST BENCH FOR SAFETY VALVES

TEST BENCH FOR SAFETY VALVES TEST BENCH FOR SAFETY VALVES 1) Hydro panel : This Panel possesses This Bench Contains One Panel and One Reservoir. 1 No. Monobloc Version : Single Phase AC, 50 Hz Type of Duty :S1 (Continuous) Class of

More information

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument

More information

KJ4000 Operating Instructions & Parts Manual NSN

KJ4000 Operating Instructions & Parts Manual NSN KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page

More information

Installation and Use Manual

Installation and Use Manual Installation and Use Manual EMASMB & LMASMB Surface Mount Bottle Filling Stations Model EMASMB IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL.

More information

PANACEA P100 LOW PRESSURE USER MANUAL

PANACEA P100 LOW PRESSURE USER MANUAL Basic Features Stainless steel body with 7/8 outside diameter. Will fit into wells down to 1 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground surface

More information

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270 SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP Simple Inexpensive Foam Proportioner Portable Inlet Pressure Choices 90 to 200 PSI Foam Rate 44 GPM to 362 GPM Salt Water Compatible Special Flow And Pressure

More information

Suggested Installation & Operating Instructions for Sidewinder Pumps

Suggested Installation & Operating Instructions for Sidewinder Pumps Model 164 C P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pump Suggested Installation & Operating Instructions for Sidewinder

More information

Putting it All Together: Making Sense of Drip Irrigation UC Master Gardener Conference August 24, 2017

Putting it All Together: Making Sense of Drip Irrigation UC Master Gardener Conference August 24, 2017 Putting it All Together: Making Sense of Drip Irrigation UC Master Gardener Conference August 24, 2017 Chuck Ingels Farm & Horticulture Advisor caingels@ucanr.edu http://ccag-eh.ucanr.edu/ http://sacmg.ucanr.edu/

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Fiberstars Light Streams Mini Laminar Installation Manual (LSML) 3072091 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15056-00 Rev. A Page 1 of 6 SAVE THESE INSTRUCTIONS!

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual STOP! Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY

More information

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:...

More information

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

DS05C,D,G Dial Set Pressure Regulating Valves

DS05C,D,G Dial Set Pressure Regulating Valves DS05C,D,G Dial Set Pressure Regulating Valves APPLICATION The Honeywell DS05C,D,G Dial Set Pressure Regulating Valve is a high quality pressure regulating valve that maintains a constant outlet pressure

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

MANUAL BE SERIES Test Benches

MANUAL BE SERIES Test Benches The CustomCrimp Manual BE Series Test Benches are designed with features that make proof and burst testing of hydraulic hose assemblies a quick and easy procedure. CUSTOMIZED AND SPECIAL DESIGN BENCHES

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll

More information

INSTALLATION OPERATION MAINTENANCE

INSTALLATION OPERATION MAINTENANCE Bermad Electrically Controlled On-Off Deluge Valve Model: 400E-3D INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

SM Models Manual Control

SM Models Manual Control SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)

More information

ISOMEGA BLADDER PUMPS

ISOMEGA BLADDER PUMPS ISOMEGA BLADDER PUMPS INSTRUCTION MANUAL Complete instructions for operation of Monoflex Isomega Bladder Pumps, Air/Gas Displacement Pumps and the Monoflex Integrated Vacuum Pressure Controller. Monoflex

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation Size: inch / mm Every Ross Valve shall be hydrostatically tested for body integrity and tight seating

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making

More information

Livewell/Baitwell Pumps. Livewell/Aerator

Livewell/Baitwell Pumps. Livewell/Aerator Livewell/Baitwell Pumps 03 Livewell/Baitwell Pumps Livewell/Aerator 049 050 03 Livewell / Baitwell Pumps selection GUIDE Livewell / Baitwell Pumps Tournament Series Bronze Base Fitting Discharge Outlet

More information

SM Models Manual Control

SM Models Manual Control SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)

More information

TurboDraft Fire Eductor

TurboDraft Fire Eductor TurboDraft Fire Eductor Operating Manual Introduction The TurboDraft is designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner.

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 46501 and 465010 Hydrostatic Test Pumps 46501 DIMENSIONS: WEIGHT: PUMP: ENGINE: CONTROL: GAUGE: DISCHARGE HOSE: INLET HOSE: 28 (70cm) L x 24 (60cm) W x 35 (87.5cm) H 136 lbs.

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS FLOJET Beer Pump Panels MODEL NO. 66134-1 66134-2 66134-3 66134-4 IMPORTANT INFORMATION This manual has been prepared to assist you in the operation of Perlick Beer

More information

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter 0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

PANACEA P125 USER MANUAL

PANACEA P125 USER MANUAL Basic Features Stainless steel body with 1.125 outside diameter. Will fit into wells down to 1-1/4 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground

More information

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12) LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation

More information

Chemical Injection Technologies Installation/Service Bulletin

Chemical Injection Technologies Installation/Service Bulletin Bulletin 4002 Chemical Injection Technologies Installation/Service Bulletin SUPERIOR Series CL-16/26/56 Automatic Switchover Gas Chlorinator - Installation & Operation IMPORTANT!! READ THESE PRECAUTIONS

More information

Bermad Model:

Bermad Model: Bermad Model: 405-02 Manually Operated Hydraulic Valve INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working with and around

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:... 1 2.1 Regulator

More information

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h) Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h) 100 PPD (2 kg/h) Maximum 250 PPD (5 kg/h) Maximum 500 PPD (10 kg/h) Maximum - 1-122.6006.9 These instructions describe the

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

PANACEA P200 STAINLESS STEEL USER MANUAL

PANACEA P200 STAINLESS STEEL USER MANUAL Basic Features Stainless Steel body with 1.75 outside diameter. Will fit into wells down to 2 (schedule 80). Has an internal chamber volume of 200mL. Maximum depth below ground surface of 3000ft. Other

More information

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013 October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve

More information

KC Series Gas Components and Supply Design Guide

KC Series Gas Components and Supply Design Guide Technical Bulletin KC Series Gas Components and Supply Design Guide GF-1030 General AERCO KC Series gas fired potable water heaters and boilers are modulating input devices that require an adequate volume

More information

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps 0.20 5.1 ROYTRONIC EXCEL TM AD Electronic Metering Pumps LMI ROYTRONIC EXCEL AD pumps achieve a new level of innovation in solenoid-driven metering pump technology. Offering a robust design, micropressor

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS 1 Introduction... 1 2 Abrasive Regulator... 2 2.1 Regulator Installation... 2 Location... 2 Attaching the Regulator to the Machine...

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Easy Nest Kits. Installation Suggestions

Easy Nest Kits. Installation Suggestions Easy Nest Kits Installation Suggestions 2 General Recommendations Hydraulics Vacuum breakers should be installed to prevent siphoning. Flexible connectors should follow FRP tank manufacturers recommendations.

More information

FI-25V OWNER S MANUAL

FI-25V OWNER S MANUAL OWNER S MANUAL SIDE VIEW INSIDE VIEW - CONTROL PANEL 04/18/07 PARTS LIST ITEM PART NO. DESCRIPTION 1 2 TANK25 DFP8 25 GALLON MOLDED TANK 8 CAP FOR 25 GALLON TANK 3 4 H34-30 HBSS1234 FOAM DISCHARGE HOSE

More information

TEST SPECIFICATION NYT-909-C

TEST SPECIFICATION NYT-909-C 748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE

More information

Hydrotherapy Jets System for a Fiberglass Pool

Hydrotherapy Jets System for a Fiberglass Pool Page 1 of 5 Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 6 - Female slip/female slip unions 2 - Female slip/fpt union

More information

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION. GSR500 Ram Assembly General Description The GSR500 single post lift / ram uses a 3-1/4 air powered cylinder, which is welded to a heavy gauge base. It is normally used to raise and lower a fluid handling

More information

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS TABLE OF CONTENTS TABLE OF CONTENTS...2 GENERAL RECOMMENDATIONS...2 TROUBLESHOOTING GUIDE...3 EXISTING EASY NEST SYSTEM TROUBLESHOOTING GUIDE...4 COMPONENT

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

Installing ASI Umbilical Delivery Systems

Installing ASI Umbilical Delivery Systems Rev A 05 Nov 2015 Page 1 of 10 PURPOSE This guide provides an overview of tubing connections into an ASI wall-mounted Junction Box that has already been plumbed with a compressed air connection including

More information

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations INSTALLATION, CARE & USE MANUAL EMASMB & LMASMB Surface Mount Bottle Filling Stations IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide 1. Accumulators Problem Accumulator is overflowing If Accumulator continues to overflow Correction 1. Push and hold the manual activation button

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents bathrooms.com Concentric Thermostatic Shower Mixers Contents Page 3 - General Information & Safety Page 4 - Installation Page 5 - Concentric Valve Set-up Page 6 - Exposed fitting of Concentric Mixer Valves

More information

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page Operations Manual Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page SG1 Overview and Dimensions 5.25 / 133 mm PS Power Supply Connection 4.06 / 103 mm Top

More information

TROUBLESHOOTING GUIDELINES

TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES PROBLEM: Performance 1. The most common problem in this area comes from inadequate flow to the LAKOS Separator(s). All LAKOS Separators operate within a prescribed flow range

More information

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump A. PARTS MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump Assembly & Operating Instructions Parts for liquid chlorine pump head 1pc. 1/4 poly delivery tubing, 4 meters 1pc. drum

More information

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR Installation Manual Model # SF-3W Arch Chemicals, Inc. 1200 Lower River Road. P.O. Box 800 Charleston, TN 37310-0800 1-800-4-PULSAR 9/16/03 REV 1 Product Stewardship MAKING THE WORLD A BETTER PLACE Arch

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

TJF-Q180V Cleaning and Disinfection Checklist

TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist TJF-Q180V Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-Q180V has been performed

More information