Technologies for Microassembly: Selected Methods
|
|
- Kelley Hines
- 5 years ago
- Views:
Transcription
1 Technologies for Microassembly: Selected Methods 4M 2007 Conference 3-5 October 2007, Borovets, Bulgaria. ASSEMIC Invited Session
2 Micro-joining by hot gas stream Laser based micro-assembly system Contactless microdispensing system
3 Micro-joining by hot gas stream Development of a micro-assembly system based on hot air stream joining (TU Vienna - ISAS) Gas supply - low production costs - simplicity of use - possibilty for integration into existing production lines - applicability for different materials combinations Compressor Heating tube Nozzle Hot gas stream Substrate with µ-part
4 Laser based micro-assembly system Development of an advanced laser based Pick and Join tool and of a microassembly system Innovative methods and processes for micro-welding of polymeric parts (Fraunhofer ILT) - new laser sources - innovative joining processes - high flexibility and processing speed - increased robustness - high accuracy
5 Contactless microdispensing system Ana Almansa (Profactor Research & Solutions GmbH) Fratila, Bou, Palfinger, Mann (Profactor R&S), Möst (PICO Dosiertechnik) PROFACTOR Research and Solutions GmbH A-2444 Seibersdorf, Austria, Forschungszentrum Tel , Fax
6 Outline Introduction Adhesive Dispensing processes and principles Description of PROFACTOR measuring set-up First results Conclusions
7 Introduction
8 Dispensing processes- Brief introduction Microdispensing: key process in many production processes Packaging, automotive, (typically automatic dispensing) Lower volume, craft based industries, (frequently manual dispensing from a cartridge using e.g. sealant gun or tool) Electronics and Microsystems (challenging task due requirement for very high precision at high production rates) Different types of adhesive processes Contact / contactless dispensing Single component / Multicomponent adhesive Distinct fluid properties (anisotropic, thermally conductive, IR curing.) Wide range of applications Dispensing of lubricant Adhesive processes Colour, lack, dot marking Dispensing of cleaning fluids and reactive substances Surface coating Sealing, protection, isolation Source: PICO Dosiertechnik GmbH
9 Typical problems with dot dispensing Tailing typical needle dispensing problem Tombstoning a component rises at one side during cure because of uneven forces in the adhesive result of an inaccurate dispense, poorly designed process, or improperly handled materials. Stringing break up of the adhesive between nozzle and substrate Consequence of too hight ejection speed for the viscosity/cohesive strength of adhesive. No dispense due to insufficient force next dot due to have twice nominal size) Popcorning Result of air or moisture getting into the adhesive and popping out during the curing stage usually results from improper handling of fluid or using out of date material Satellites frequent in high speed dispensing may be caused by air bubbles Source: Satellite Drop formation SourceSMT magazine (4/2001) Tailing
10 Description of PROFACTOR Contactless Microdispensing System measuring set-up
11 Prototype implemented Dispensing machine DV-100 Picodostec system Contactless dispensing mode Viscosity range: mpas Minimum dispensing time from 10 µs XY Micropositioning Table travel distance from 250 mm High accuracy Glass plate for enabling through view USB Camera 1024x768px, 8bit Optic 2 different telecentric objectives Area Pixel Size Exposure time T50/1.0 5/3.75mm 5µm 10ms T107/ /11.25mm 15µm 5ms
12 PROFACTOR Microdispensing measuring set-up Light difusion for enhanced light homogeneity XY Micropositioning stage integrating glass plate for enabling through view PICODOS contactless Microdispensing unit System Control and image processing Software Drop array dispensing glass plate Circular light source mounted for optimal illumination incidence angle Camera and telecentric objective Microdispensing control unit and interface Hardware
13 The PICODOS Microdispensing unit The dispensing valve is actuated by two piezoactuators onto a rod, with a ceramic sealing ball attached to its end Piezoactuator frequencies of up to 1000 Hz enable dispensing amounts of down to approx. 2nl are possible PICODos dispensing valve Contactless dispensing with distance of up to several centimeters (single drops or continuous flux) The dispensing valve integrates a heating element which allows to control the temperature of the fluid within the needle valve (e.g. to change viscosity or attain operating working temperature)
14 Microdispensing process control The hardware developed enables remote computer control of the dispensing system and integrates galvanic isolation through 8x Optical coupling device between the computer and dispensing unit circuit (3.8 to 24 Volt)
15 Image processing method A challenge for image processing: Vision based analysis of transparent drops through a glass plate Border Contrast by a total reflection light on the drop surface. Sharp edge at the border of the drop Tailing primary beams
16 Image processing Method Imaging Manual Threshold Fill Holes Dilate and Erode Dilate and Erode Convolute Illumination optimized typical Intensity profile
17 Analysis of the drops The questions The answers X,Y central position Has the drop been adequately dispensed? Are the drops homogeneous? Are the drops displaced from the target position? Are there existing satellite drops? Are the drops too large or too small? Are there detectable faults in the adhesive or dispensing process? What is the process repeatability? Perimeter & diameter Number of holes Area Ratio of equivalent ellipse Ratio of equivalent radius Excentricity: Outer inner radius Presence and number of satellite drops Statistic values
18 System control software and user interface System control and user interface developed in NI LabView Automatic control of positioning table and dispensing unit Automatic or user driven vision based analysis of the drops Data exportable as excel table High degree of configurability
19 First results
20 First tests Experimental conditions First experiments where done with oil- providing particularly challenging conditions due to: Low viscosity Transparency Difficulty to dispense Variability
21 Results of first experiments Formation of air bubbles The temperature increase failed to solve the problem Air bubbles only disappeared after few minutes The problem was solved by new optimization of measurement set-up and program Dynamic evolution of the drops due to low viscosity and fluid properties (the area increased with time) Effect was successfully measured and recorded by PROFACTOR measuring system Satellites were formed Effect was detected by the measuring system and could be corrected after readjustment of dispensing parameters
22 Conclusions
23 Conclusions Profactor has developed in cooperation with PICO Dosiertechnik an automated system for measurement and characterization of dispensed microdrops The system has a high degree of flexibility and configurability, in order to be easily adapted to difference process conditions, fulfilling the needs of the customer. Further work is planned, in order to enable on-line measurement and integration in closed-loop dispensing processes
24 Acknowledgements This work was made possible thanks to the partial support of the European Commission through the Marie Curie Actions in the 6th Framework Programme and to the main support and strong contribution of the company PICO Dosiertechnik GmbH.
25 Thank you for your attention!
WHITEPAPER. Integrated process monitoring of dosing pressures
Integrated process monitoring of dosing pressures Detect and avoid errors during dosing with the flowplus 16 dosing pressure monitoring system and flowscreen Fig. 1: flowplus 16 relative pressure sensor
More informationTime Pressure Dispensing
Time Pressure Dispensing by Doug Dixon, GDM Product Manager What is time pressure dispensing? Time pressure is a method of dispensing liquid materials (surface mount adhesives and gasketing materials)
More informationA New Way to Handle Changing Fluid Viscosity and the Full-to-empty Effect
A New Way to Handle Changing Fluid Viscosity and the Full-to-empty Effect Nordson EFD, 40 Catamore Blvd., East Providence RI 02914 www.nordsonefd.com A New Way to Handle Changing Fluid Viscosity And the
More informationTechnical Note. Determining the surface tension of liquids by measurements on pendant drops
Technical Note Pendant Drop Measurements Technical note: TN316e Industry section: all Author: FT, TW Date: 12/2010 Method: Drop Shape Analyzer DSA100 Keywords: Methods, surface tension, interfacial tension,
More informationComplete Range of Force Tensiometers
Sigma Complete Range of Force Tensiometers Versatility, automation and accuracy Precision made simple Attension Force Tensiometers are used in research, development and quality control for the study of
More informationPendant Drop Measurements
KRÜSS pplication Note TN316d Page 1 Pendant Drop Measurements pplication note: TN316d Industry section: all uthor: Dr. Tobias Winkler Date: December 2010 Method: Drop Shape nalysis System DS100 Drop Shape
More informationsorting solutions osx separator series
osx separator series Comex offers a newly developed complex optical sorting system, in a user friendly platform, for the identification and separation of particles and materials, based on their many physical
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More information2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications
Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity
More informationSensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual
Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik
More informationINTRODUCTION TABLE OF CONTENTS
2 INTRODUCTION Thank you for choosing Servometer to design and manufacture your unique, new electrodeposited bellows for your particular application. The definitions, formulas and design parameters inside
More informationGAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE
GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE www.helantec.de Gas filling - visibly better! 2 Managing partners Jochen Weiß and Gregor Witrofsky Advantage for you Worldwide, HELANTEC is the
More informationPRC CO ² -LASER PRESENTATION
Page 1 of 7 PRC CO ² -LASER PRESENTATION GENERAL CHARACTERISTICS - Embedded PC104 Electronics with exchangeable software allowing very easy integration of customer specified functions: such as eg. specific
More informationLevel MEASUREMENT 1/2016
Level MEASUREMENT 1/2016 AGENDA 2 A. Introduction B. Float method C. Displacer method D. Hydrostatic pressure method E. Capacitance method G. Ultrasonic method H. Radar method I. Laser method J. Level
More informationTensiometer For the measurement of surface and interfacial tension
Tensiometer For the measurement of surface and interfacial tension Precise measuring instruments for research and industry Precision, flexibility, and reliability LAUDA Scientific offers proven solutions
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationTensiometer For the measurement of surface and interfacial tension
Tensiometer For the measurement of surface and interfacial tension Precise measuring instruments for research and industry Precision, flexibility, and reliability LAUDA Scientific offers proven solutions
More informationNickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO
Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8
More informationA Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers
A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers Slemeyer, A. University of Applied Sciences of Giessen, Dept. of Electrical Engineering 1 Wiesenstr. 14, D-35390
More informationOxidation Stability of Gasoline and Aviation Fuels
Oxidation Stability of Gasoline (Induction Period Method) Oxidation Stability of Aviation Fuels (Potential Residue Method) Test Method Provides an indication of the tendency of gasoline and aviation fuels
More informationResidual Gas Analysis Systems for Industry
HIDEN RC SYSTEMS QUADRUPOLE MASS SPECTROMETERS FOR RGA, GAS ANALYSIS AND PROCESS MONITORING The HAL RC systems are designed for RGA, gas analysis and process monitoring applications including leak detection,
More informationUNIVERSITY OF WATERLOO
UNIVERSITY OF WATERLOO Department of Chemical Engineering ChE 524 Process Control Laboratory Instruction Manual January, 2001 Revised: May, 2009 1 Experiment # 2 - Double Pipe Heat Exchanger Experimental
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in
More informationDevelopment of a High Pressure, Oil Free, Rolling Piston Compressor
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1994 Development of a High Pressure, Oil Free, Rolling Piston Compressor S. J. Delmotte
More informationOverspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)
Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1) Instructions for installation and operation 113 OG Моment 250 MR 115 OG Moment 250 MRL Overspeed
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationIEEE RAS Micro/Nano Robotics & Automation (MNRA) Technical Committee Mobile Microrobotics Challenge 2016
IEEE RAS Micro/Nano Robotics & Automation (MNRA) Technical Committee Mobile Microrobotics Challenge 2016 OFFICIAL RULES Version 2.0 December 15, 2015 1. THE EVENTS The IEEE Robotics & Automation Society
More informationThe M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions
The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly
More informationFigure 2: Principle of GPVS and ILIDS.
Summary Bubbly flows appear in many industrial applications. In electrochemistry, bubbles emerge on the electrodes in e.g. hydrolysis of water, the production of chloride and as a side-reaction in metal
More informationProject Title: Pneumatic Exercise Machine
EEL 4924 Electrical Engineering Design (Senior Design) Preliminary Design Report 27 January 2011 Project Title: Pneumatic Exercise Machine Team Members: Name: Gino Tozzi Name: Seok Hyun (John) Yun Email:
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationProject Number: P14474
Multidisciplinary Senior Design Conference Kate Gleason College of Engineering Rochester Institute of Technology Rochester, New York 14623 Project Number: P14474 HYDROSTATIC TEST APPARATUS Anushka Kalicharan
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationThe HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator
The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric
More informationFigure 1 Schematic of opposing air bearing concept
Theoretical Analysis of Opposing Air Bearing Concept This concept utilizes air bearings to constrain five degrees of freedom of the optic as shown in the figure below. Three pairs of inherently compensated
More informationFTC130 Transmitter. Operating Manual
Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and
More informationKM/31000 (Stainless steel end plates) Air bellows, single acting
KM/ (Stainless steel end plates) > > Ø... / inch (... mm) > > Very easy to install no alignment problems > > Almost frictionless operation > > No maintenance or lubrication > > Typical applications; actuator,
More informationSeries Environmental Chambers
3119-600 Series Environmental Chambers Challenges in Non-Ambient Testing Testing at non-ambient temperatures adds another layer of challenges to your testing laboratory. Ensuring you get accurate and stable
More informationF l o w c o n T R o l v a l v E S
Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,
More informationInstruction Manual Otoflash G171 UV-flash-device for Light Curing
Instruction Manual Otoflash G171 UV-flash-device for Light Curing Index 1) General Information 2) Initial Operation of Device 3) Important Notes 4) Use with timer 5) Exchanging the flash module 6) Maintenance,
More informationTesting of Active Flow Control actuators at harsh environment
Testing of Active Flow Control actuators at harsh environment Ionut BRINZA (INCAS) 6 th CEAS CONFERENCE 16-20 October 2017 Bucharest ROMANIA Introduction Results of the harsh environment tests Conclusions
More informationAC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW
AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi
More informationInfluencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology
More informationPress Release. Friction Stir Welding: Grenzebach extends its portfolio
Friction Stir Welding: Grenzebach extends its portfolio Higher dynamics, higher welding speeds, lower process forces and even higher quality welding seams and welding surfaces: at the Düsseldorf Schweissen
More informationHermetic Compressor Manifold Analysis With the Use of the Finite Element Method
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Hermetic Compressor Manifold Analysis With the Use of the Finite Element Method Rinaldo
More informationNew power in production logging
New power in production logging Locating the zones where fluids enter the wellbore in a producing or injecting well is an important aspect of production logging. It is relatively straightforward to establish
More informationWHITEPAPER. The flowplus 16 Pressure Sensor. Physical Principles and Function
The flowplus 16 Pressure Sensor Physical Principles and Function Sensors (from the Latin "Sensire") are devices by means of which it is possible to detect physical or chemical properties of materials.
More informationUnderstanding How the Appearance of Optical Fiber Splices Relates to Splice Quality
Understanding How the Appearance of Optical Fiber Splices Relates to Splice Quality Douglas Duke & David Mansperger Fusion Splicing Systems, AFL, Duncan, SC Doug.Duke@AFLglobal.com David.Mansperger@AFLglobal.com
More informationDCA Modified Alkyd Conformal Coating (SCC3)
Page 1 DCA Modified Alkyd Conformal Coating (SCC3) DCA is a flexible, transparent and unique modified alkyd conformal coating specifically designed for the protection of electronic circuitry. It has been
More informationACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING
ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING Blair Chalpin Charles A. Matthews Mechanical Design Engineer Product Support Manager Scanivalve Corp Scanivalve Corp Liberty Lake, WA
More informationRadar, Ultrasonic and RF Level Transmitters
Radar, Ultrasonic and RF Level Transmitters Both measures the time it takes the wave to travel between the transmitter and that reflected wave off the surface of the material to reach the transmitter again.
More informationReliable, accurate groundwater Diver dataloggers and software. Diver-Suite
Reliable, accurate groundwater Diver dataloggers and software Diver-Suite SMART MONITORING TECHNOLOGY Diver-Suite*, from Schlumberger Water Services, provides groundwater and environmental professionals
More informationHydrogen Bubble Seeding for Particle Image Velocimetry
Hydrogen Bubble Seeding for Particle Image Velocimetry Benjamin T. Hillier 1 and Mitchell A. Schram. 2 The University of Melbourne, Melbourne, Victoria, 3010, Australia Dr. Jason P. Monty 3 The University
More informationAir Compressor Control System for Energy Saving in Manufacturing Plant
IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 2 August 2014 ISSN(online) : 2349-784X Air Compressor Control System for Energy Saving in Manufacturing Plant Ms. Snehal
More informationControl & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system
Control & Maintenance INT69 Diagnose INT69 TM Diagnose Protect the heart of your system R INT69 DIAGNOSE The widely known protective system INT69 and INT69 TM present on all Frascold compressors is now
More informationPlasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.
Yamato Scientific America Innovating Science for Over 125 Years Plasma Cleaner Contents Gas Plasma Dry Cleaner PDC200/210/510 PDC610G Gas Plasma Reactor 145 146 147 149 144 Gas Plasma Dry Cleaner Plasma
More information...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com
...makes sense! Combined CO 2 /O 2 analyzers Monitor your process in real-time: BlueSens.com OUR CER RQ ...makes sense! The BlueInOne sensor BlueSens is providing modern and inexpensive measuring solutions
More informationMicro-Venturi injector: design, experimental and simulative examination
Journal of Physics: Conference Series PAPER OPEN ACCESS Micro-Venturi injector: design, experimental and simulative examination To cite this article: S Degenhardt et al 2016 J. Phys.: Conf. Ser. 757 012027
More informationISE Subsea Tools and Toolsleds
1734 Broadway St. Port Coquitlam, B.C. V3C 2M8, Canada +1.604.942.5223 +1.604.942.7577 info@ise.bc.ca www.ise.bc.ca ISE Subsea Tools and Toolsleds 1 INTRODUCTION The value of an ROV is increased by its
More informationInflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer
Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump
More informationProgrammable Valves Enable Both Precision Motion Control and Energy Saving
Programmable Valves Enable Both Precision Motion Control and Energy Saving Dr. Bin Yao Purdue University West Lafayette, IN 47907, USA 1 Outline Development of Programmable Valves Control of Programmable
More informationOD plug gauge. for bores and internal profiles from dia. 2,5 mm. OD plug gauge in open design. Special designs Accessories. OD plug gauge for various
OD plug gauge for various bore diameters Cross sleeve Cross sleeve with runners OD plug gauge for bores and internal profiles from dia. 2,5 300 Oskar Schwenk GmbH & Co. Esslinger Straße 84 70736 Fellbach
More informationBSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.
1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationDouble Emulsion Droplet generation and collection protocol Version Author Date Reviewer Change 1 Introduction
Blacktrace Holdings Ltd Double Emulsion Droplet generation and collection protocol Version Author Date Reviewer Change 1 NNM 03/02/17 1 Introduction The Dolomite double emulsion system is a powerful, versatile
More informationPrecision level sensing with low-pressure module MS
The task on hand Level sensing as it is understood in modern process automation is much more than simply "tank half full" or "tank a quarter full". Using suitable sensors, levels, inlets and outlets can
More informationAir Displacement Pipetting Modules. Total Integrated Liquid Handling
Air Displacement Pipetting Modules Total Integrated Liquid Handling Intelligent Liquid Handling For Better Results MOVING LIQUID IS EASY; PRECISION LIQUID HANDLING IS HARD Instrument manufacturers frequently
More informationDevelopments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry
Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry Franz Trieb, Reinhard Karl, Rene Moderer Bohler Hochdrucktechnik GmbH Kapfenberg, Austria www.bhdt.at
More informationIBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES
IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES GAS SAFETY ENGINEERING GAS MANIFOLD SYSTEMS AUTOGENOUS ENGINEERING FLAME SPRAYING GAS MIXERS IBEDA GAS MIXERS FOR MANY AREAS OF
More informationNR-Tec Ltd. S2S SMARTSHOT Acoustic Fluid Level Instrument
NR-Tec Ltd. S2S SMARTSHOT Acoustic Fluid Level Instrument The S2S SmartShot is a single shot, manually operated fluid level instrument with next generation SmartShot Technology. This new technology enhances
More informationT e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.
MU047: Practical Valve Technology: Selection, Installation, Upgrading, Inspection & Troubleshooting MU047 Rev.002 CMCT COURSE OUTLINE Page 1 of 7 Training Description: This five-day intensive course covers
More informationThe NXT Generation. A complete learning solution
The NXT Generation A complete learning solution 2008 The NXT Generation LEGO MINDSTORMS Education is the latest in educational robotics, enabling students to discover ICT, science, D&T and maths concepts
More informationLaserSnake Underwater Laser Cutting Phase 1 TWI
LaserSnake2 110128 Underwater Laser Cutting Phase 1 TWI-002 6-13 Contents 1 Introduction 1 2 Objectives 1 3 Underwater Cutting Nozzle Design and Operation 1 3.1 Design 1 3.2 Dry-zone testing 3 4 Equipment
More informationProcessing instructions V 3.6 REFRAJET Nanobond
Refratechnik Steel GmbH Schiessstrasse 58 40549 Düsseldorf Germany Phone: +49 211 5858 0 Fax: +49 211 5858 49 steel@refra.com www.refra.com Processing instructions V 3.6 Note: Please read the product information
More informationComputer Integrated Manufacturing (PLTW) TEKS/LINKS Student Objectives One Credit
Computer Integrated Manufacturing (PLTW) TEKS/LINKS Student Objectives One Credit Suggested Time Ranges First Six Weeks History of Manufacturing PFD 1.1(A) The student will describe why and how manufacturing
More informationAMS 6916 Board mount pressure sensor with ratiometric analog output
FEATURES Piezoresistive pressure sensor with amplified analog output Calibrated and temperature compensated Ratiometric voltage output, 0.5 4.5 V Digital signal conditioning, 12 bit output resolution Differential,
More informationAIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT. Technical Brochure ON RUNNING ENGINES
AIR-X COMPACT AIR-X ON-LINE LUBRICANT AERATION MEASUREMENT ON RUNNING ENGINES Technical Brochure 2015 Introduction The presence of air in the fluid of a working hydraulic system can cause significant performance
More informationInput Systems. schurter.com/input-systems. Touchscreen Lösungen solutions Kapazitive Capacitive Schaltelemente Folientastaturen.
schurter.com/input-systems Integrierte Integrated Lösungen solutions Touchscreen Lösungen solutions Kapazitive Capacitive Schaltelemente switch solutions Folientastaturen Membrane switches Gehäuse Housing
More informationNew Highly Productive Phased Array Ultrasonic Testing Machine for Aluminium Plates for Aircraft Applications
19 th World Conference on Non-Destructive Testing 2016 New Highly Productive Phased Array Ultrasonic Testing Machine for Aluminium Plates for Aircraft Applications Christoph HENKEL 1, Markus SPERL 1, Walter
More informationComparative temperature measurements in an experimental borehole heat exchanger. Vincent Badoux 1, Rita Kobler 2
European Geothermal Congress 2016 Strasbourg, France, 19-24 Sept 2016 Comparative temperature measurements in an experimental borehole heat exchanger Vincent Badoux 1, Rita Kobler 2 1 GEOTEST AG, Bernstrasse
More informationbetter measurement Simply a question of
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology
More informationVERTICAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationUsER manual for Watersens ph -REDOX
UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5
More informationGROUTEC SCOTT VICKERS. Grouting Equipment
GROUTEC SCOTT VICKERS Grouting Equipment SCOTT VICKERS manufacturers a range of cement and chemical grouting equipment including:- PUMPS - The Cement Grout Pumps are all diaphragm-type. These diaphragms,
More informationVortex Meters for Liquids, Gas, and Steam
A Measuring Principle Comes of Age: Vortex Meters for Liquids, Gas, and Steam Dipl.-Hyd. Oliver Seifert, Product Management Vortex Meters at Flowtec AG, and Ellen-Christine Reiff, M.A., Editor s Office,
More informationAMS 6915 Board mount pressure sensor with digital output (I²C)
Board mount pressure sensor with digital output (I²C) FEATURES Calibrated and temperature compensated pressure sensor with digital output (I²C) Differential, relative (gage), bidirectional differential,
More informationZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006
ZIN Technologies PHi Engineering Support PHi-RPT-0002 CFD Analysis of Large Bubble Mixing Proprietary ZIN Technologies, Inc. For nearly five decades, ZIN Technologies has provided integrated products and
More informationFAST EVAPORATION AT NORMAL PRESSURE
FAST EVAPORATION AT NORMAL PRESSURE FAST EVAPORATION BY BLOWING-DOWN... The VAPORNADO Plus blow-down system is an innovative and efficient instrument for the evaporation of samples and fractions at normal
More informationValve test benches. Systems overview
Valve test benches Systems overview About us In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within
More informationHiFocus 280i / 360i / 440i
Plasma Systems i / i / i of Metals from 0.5 up to 100 mm made in Germany Plasma cost-efficient and flexible as never before Plasma cost-effcient and flexible as never before If cutting shops and users
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationLab 4: Pressure Gradients over a Wing
2009 Lab 4: Pressure Gradients over a Wing Innovative Scientific Solutions Inc. 2766 Indian Ripple Road Dayton, OH 45440 (937)-429-4980 Lab 4: Pressure Gradients over a Wing Introduction: Like the previous
More informationTRAINING SCHEDULE FLUID POWER TRAINING CUSTOM TRAINING PRODUCT TRAINING
TRAINING SCHEDULE 2018 FLUID POWER TRAINING CUSTOM TRAINING PRODUCT TRAINING Fluid Power Training CMA/Flodyne/Hydradyne offers economical four day hydraulic training classes in Basic Hydraulics, Advanced
More informationFor Multi-Parameter Meters see mvx
Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid
More informationAdvanced Test Equipment Rentals ATEC (2832) OMS 600
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMS 600 Continuous partial discharge monitoring system for power generators and electrical motors Condition monitoring
More informationDevelopment of a Miniaturized Pressure Regulation System "mprs"
Development of a Miniaturized Pressure Regulation System "mprs" IEPC-2015-365 /ISTS-2015-b-365 Presented at Joint Conference of 30th International Symposium on Space Technology and Science 34th International
More informationSpecifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)
Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS) A. Scope of Work The work covered by these specifications consists of furnishing all materials, labor,
More informationApplication Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction
Application Note Rapid performance verification of AZURA systems with refractive index detector Method Keywords ID HPLC Quality control, system verification, refractive index, AZURA Analytical HPLC Plus
More information