1 Driver Operator Pumps: Basic Pump Operations 5 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

2 Driver Operator Pumps: Basic Pump Operations Skills Book NFPA 1002 Task: JPR Driver Operator: Pumps: Basic Pump Operations 1 Produce Effective Hand & Master Streams from Static Source Produce Effective Hand & Master Streams from Pressurized Source 3 Change to Pressurized Source from Tank Pressurized Source Change to Static Source from Tank Pump a Foam Fire Stream 5.2.3

3 SKILL SHEET # 1 Produce Effective Hand & Master Streams from Static Source Performance Evaluation: The evaluator shall verify the candidate has the ability to produce effective hand and master streams from a static water source, given a fire department pumping apparatus, static water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose. JPR: Tasks: Produce effective hand and master streams. The candidate, given a fire department pumping apparatus, static water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose shall produce effective hand and master streams so that the listed performance steps are completed. Equipment Required: fire department pumping apparatus, static water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose 1. Positions fire department pumper to operate at a static water source. 5. Assembles hard suction hose as necessary. 6. Operates primer and primes centrifugal fire pump. C 7. Produces effective water stream from static water source to master stream device. C 8. Produces effective water stream from static water source to handheld nozzle. 9. Operates auxiliary cooling system. 10. Calculates friction loss and gallons per minute for each scenario given. 11. Assembles hose lines, nozzles, valves and appliances as necessary. 12. Operates the volume/pressure transfer valve (multi-state pumps only). 13. Operates pressure control system. Total 9

4 SKILL SHEET # 2 Produce Effective Hand & Master Streams from Pressurized Source Performance Evaluation: The evaluator shall verify the candidate has the ability to produce effective hand and master streams from a pressurized water source, given a fire department pumping apparatus, pressurized water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose. JPR: Tasks: Produce effective hand and master streams. The candidate, given a fire department pumping apparatus, pressurized water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose shall produce effective hand and master streams so that the listed performance steps are completed. Equipment Required: fire department pumping apparatus, pressurized water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose 1. Positions fire department pumper to operate at a pressurized water source. 5. Opens tank to pump and tank fill to begin circulating water. 6. Connects supply lines to pressurized source. 7. Operates air bleeder valves as necessary. 8. Slowly and safely opens correct intake valve, noting incoming pressure readings. 9. Closes tank fill valve to prevent overflow. Closes tank to pump valve. C10. Produces effective water stream from pressurized water source to master stream device. C11. Produces effective water stream from pressurized water source to handheld nozzle. 12. Operates auxiliary cooling system. 13. Calculates friction loss and gallons per minute for each scenario given. 14. Assembles hose lines, nozzles, valves and appliances as necessary. 15. Operates the volume/pressure transfer valve (multi-state pumps only) 16. Operates pressure control system.

5 Total SKILL SHEET # 3 Change to Pressurized Source from Tank 9 Performance Evaluation: The evaluator shall verify the candidate has the ability to safely transition from internal tank operations to operating from a pressurized water source so that effective hand and master streams are produced and maintained. JPR: Tasks: Effectively switch from internal tank operations to operating from a pressurized water source to produce effective hand and master streams. The candidate, given a fire department pumping apparatus, pressurized water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose shall produce effective hand and master streams so that the listed performance steps are completed. Equipment Required: fire department pumping apparatus, pressurized water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose 1. Positions fire department pumper to operate at a pressurized water source. 5. Opens tank to pump/tank suction. 6. Identifies and opens correct discharge valve. 7. Builds correct pressure for discharge line. 8. Correctly sets pressure control device. C 9. Assembles hose lines, valves, and appliances as necessary. 10. Transitions to pressurized water source in a coordinated manner, with minimal loss or increase in discharge line pressure. 11. Adjusts throttle to compensate for the additional intake manifold pressure. 12. Readjusts pressure control device as necessary. 13. Refills tank as necessary. Total 8

6 SKILL SHEET # 4 Change to Static Source from Tank Performance Evaluation: The evaluator shall verify that the candidate has the ability to safely transition from internal tank operations to operating from a static water source so that effective hand and master streams are produced and maintained. JPR: Tasks: Effectively switch from internal tank operations to operating from a static water source to produce effective hand and master streams. The candidate, given a fire department pumping apparatus, static water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose, and 100 feet of 1¾ discharge hose shall produce effective hand and master streams so that the listed performance steps are completed. Equipment Required: fire department pumping apparatus, static water source, master stream device, hand nozzle, 100 feet of 2½ discharge hose and 100 feet of 1¾ discharge hose 1. Positions fire department pumper to operate at a static water source. 5. Opens tank to pump/tank suction. 6. Identifies and opens correct discharge valve. 7. Builds correct pressure for discharge line. 8. Correctly sets pressure control device. 9. Assembles hard suction or other connection hoses as necessary. C10. Transitions water supply from internal tank to external static source in a coordinated manner with minimal loss or increase in discharge line pressure. 11. Adjusts throttle to compensate for the additional lift required for the external static water supply. 12. Readjusts pressure control device as necessary. 13. Refills tank as necessary. Total 8

7 SKILL SHEET # 5 Pump a Foam Fire Stream Performance Evaluation: The evaluator shall verify that the candidate has the ability to produce a foam fire stream, given a fire department pumping apparatus, an internal tank, a pressurized hydrant, foam-producing equipment, and 100 feet of 1¾ fire hose. JPR: Tasks: Produce a foam fire stream. The candidate, given a fire department pumping apparatus, an internal tank, a pressurized hydrant, foam-producing equipment, and 100 feet of 1¾ fire hose, shall produce a foam fire stream so that the listed performance steps are completed. Equipment Required: fire department pumping apparatus, an internal tank, a pressurized hydrant, foam-producing equipment, and 100 feet of 1¾ fire hose. 1. Positions fire department pumper to operate at a pressurized fire hydrant or static water source. 5. Assembles foam producing equipment and hose. 6. Ensures nozzle and educator are compatible. C 7. Sets concentration on educator. C 8. Provides correct pressure to produce a properly proportioned foam fire stream. Total 6

8 Change to Static Source from Tank Change to Pressurized Source from Tank Produce Effective Hand & Master Streams from Pressurized Source Produce Effective Hand & Master Streams from Static Source CERTIFICATION SKILLS SIGN-OFF NFPA 1002 Driver Operator Basic Pumps Skill Sheet Number Skill Sheet Title Text Reference: IFSTA Pumping and Aerial Apparatus Driver Operator Handbook, 3 rd Edition Candidate s Names

9 19. VERIFICATION Test Location: Test Date: Delivery Agency Verification (Printed) Evaluator Name (Print) Evaluator Signature: (Signature)

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Water Supplies 2 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Water Supplies Skills Book JPR NFPA 1002 Task:

More information

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/Operator Professional Qualifications, 2014 Edition. Alabama Fire College February 2016 revised

More information

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2017 Edition. Alabama Fire College August, 2018 revised

More information

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1 Skill Sheet: 1 Standard 4.2.1, 4.2.2 Task: Perform and document routine test, inspection and servicing functions on specified systems and components. Performance Outcome: Given a fire department pumping

More information

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA TOPIC: RELAY PUMPING OPERATIONS LEVEL OF INSTRUCTION: TIME REQUIRED: ONE HOUR INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO VISUAL SUPPORT REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST

More information

Apparatus Operator Refresher Training Program

Apparatus Operator Refresher Training Program Division of Training In-Service Training Program Apparatus Operator Refresher Training Program 1 Single Engine / Single Line Operation Refresher Evolution #1 Objective: Charging single handlines at correct

More information

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition) Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs ( Edition) JPR # Task Initial Certification JPR Requirement: 15 Mandatory Renewal JPR Requirement: 100% of All JPRs (including

More information

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question. Chapter 15 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Distinguish among preperformance tests for pumping apparatus. 1. Which standard is commonly

More information

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition) Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs () JPR # Task Initial Certification JPR Requirement: 15 Mandatory Renewal JPR Requirement: 100% of All JPRs (including all subsections)

More information

Driver Releasal Manual

Driver Releasal Manual Driver Releasal Manual In order to participate in the DPO program, the candidate must: o Possess a valid Virginia Driver s License o Be 18 years of age o Be covered under the County insurance policy o

More information

Apparatus Operator/Pumper

Apparatus Operator/Pumper Skill Number: AOP-1 Operate Fixed Systems Objective: 4.3.7 (A) (B) 1. The candidate shall be provided with the equipment to complete this objective including apparatus. 2. The candidate uses safety precautions.

More information

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011 W A T E R S U P P L Y O P E R A T I O N S R U R A L ( 2. 1 ) Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011 Revised by Lt. Greg Van Heel, Eng. Chris Wining, and FF. Uriel

More information

Fire Service Training The University of Kansas. Fire Apparatus Driver/Operator Study Guide June National Certification Program

Fire Service Training The University of Kansas. Fire Apparatus Driver/Operator Study Guide June National Certification Program Fire Service Training The University of Kansas National Certification Program Fire Apparatus Driver/Operator Study Guide June 2001 This document is provided at no cost to the user by Fire Service Training,

More information

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU FIRE FIGHTER II SKILL STATION MENU STATION TASK(S) A FIREGROUND OPERATIONS/FIRE COMMUNICATIONS MANDATORY B SPRINKLER DRAIN/PRESSURES RANDOM C PITOT GAUGE USE RANDOM D INSPECTION/MAINTENANCE: GENERATOR,

More information

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET Fire Fighter II Skill Stations: NFPA 1001 2013 Edition Station A Fire Ground Communications & Operations / Interior Attack Coordination MANDATORY STATION Station B Sprinkler Drain/Pressures RANDOM STATION

More information

TurboDraft. Fire Eductor Operating Instructions.

TurboDraft. Fire Eductor Operating Instructions. TurboDraft Fire Eductor Operating Instructions 1234djfkjldfjlkdjfklsdjlkjfdslkjfsd Table of Contents Description Page Introduction........ 1 Safety Guidelines... 2 Care and Maintenance... 3 TurboDraft

More information

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019 Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019 Effective 1/1/2019 Fire Apparatus Driver/Operator-Pumper Practical Skill Sheets 1 Table of Contents Acknowledgements... 3 Driver/Operator

More information

Des Plaines Fire Dept. Engineer Program

Des Plaines Fire Dept. Engineer Program Des Plaines Fire Dept. Engineer Program Lieutenants Palenik, Gross, Owen, Butenschoen, Engineer Felde New Developments 1. Laminated fluid specs on the rigs 2. Maintenance repair request updates 3. Locations

More information

TurboDraft Fire Eductor

TurboDraft Fire Eductor TurboDraft Fire Eductor Operating Manual Introduction The TurboDraft is designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner.

More information

FIRE FIGHTER II JPR: FFII-1A

FIRE FIGHTER II JPR: FFII-1A JPR: FFII-1A STANDARD: 6.1.2 Task: Implement Incident Management System. General Requirements The candidate shall demonstrate the ability to determine need for command, organize and coordinate an incident

More information

Chapter 14 Water Shuttle Operations

Chapter 14 Water Shuttle Operations 1. Which of the following statements about water shuttle operations is TRUE? A. Water shuttle operations may create a dramatic hose failure B. Water shuttle operations are safer than relay pumping operations

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised DRIVER OPERATOR Page 1 of 14 HYDRAULICS Hydraulics applied in the dynamic fire ground environment is an art that comes with study and experience. The following describes the factors that must be mastered

More information

Varying pump capacity affects the required hoseline diameter

Varying pump capacity affects the required hoseline diameter Slide 1 Rural Fire Command by Larry Davis Issue #34 October 2005 H 2 O On The Go Varying pump capacity affects the required hoseline diameter 1 Slide 2 Training America s Rural Fire & Emergency Responders

More information

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011 W ATER S UPPLY O PERATIONS R URAL (1.1) Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011 NFPA 1142 Standard on Water Supplies for Suburban and Rural

More information

Fire Apparatus Operator: ARFF

Fire Apparatus Operator: ARFF Fire Apparatus Operator: ARFF Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2017 Edition. Alabama Fire College November 26, 2018 Alabama

More information

Cozumel Turbodraft. Operational Considerations

Cozumel Turbodraft. Operational Considerations Cozumel Turbodraft Operational Considerations Safety Guidelines Safety Guidelines 1. Carefully read and follow all operating instructions before putting the TurboDraft unit into service. 2. Be sure all

More information

Fire Apparatus Operator Aircraft Rescue and Fire Fighting

Fire Apparatus Operator Aircraft Rescue and Fire Fighting Fire Apparatus Operator Aircraft Rescue and Fire Fighting Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2014 Edition. Alabama Fire College

More information

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010 W ATER S UPPLY O PERATIONS M UNICIPAL/SUBURBAN (1.1) Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010 NFPA 1142 Standard on Water Supplies for Suburban

More information

Essentials of Fire Fighting

Essentials of Fire Fighting Essentials of Fire Fighting 6 th Edition Certified Volunteer Firefighter Chapter 14 Water Supply Learning Objectives Explain the ways water supply system components are used by firefighters. Describe types

More information

Head to Head Demo Comparison Sheet

Head to Head Demo Comparison Sheet Head to Head Demo Comparison Sheet Task Force Tips Crossfire Portable/Deck Mount Monitor The purpose of this document is to encourage you to compare TFT products head to head, apples to apples, with like

More information

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION FIREFIGHTER 2 PERFORMANCE EVALUATION

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION FIREFIGHTER 2 PERFORMANCE EVALUATION JPR Task: Establish Incident ommand and oordinate Interior andidate # Attack of a Structure Fire Skill No. 2-1 RITERIA AND INSTRUTIONS 1. The candidate provided with a radio and scenario to establish an

More information

Florissant Valley Fire Protection District Monthly Training Schedule

Florissant Valley Fire Protection District Monthly Training Schedule Florissant Valley Fire Protection District Monthly Training Schedule March 2013 Weekly Skill Drill Summary *Required by All Individuals* Subject Dates Description and Requirement Extension Ladders March

More information

FIREGROUND HYDRAULICS

FIREGROUND HYDRAULICS INTRODUCTION This section is designed to give pump operators a quick and fairly easy process for determining fire ground hydraulics. Supplying water is a critical part of the control, and the efficient

More information

Pump Stages. By Tom Murray

Pump Stages. By Tom Murray Pump Stages By Tom Murray As is often the case, we in the fire service tend to make things more difficult than they need to be. I believe this is the situation when discussing the pros and cons of single,

More information

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program Welcome & Introductions Identify emergency exits to all participants. Identify location of restroom facilities. Cover any other related

More information

Essentials of Fire Fighting 6 th Edition Firefighter I

Essentials of Fire Fighting 6 th Edition Firefighter I 1 Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 14 Water Supply Learning Objective 1 2 Explain the ways water supply system components are used by firefighters. 14 2 There are two types

More information

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal F I R E A P P A R A T U S DRIVER/OPERATOR 1B Approved and Adopted by the Office of State Fire Marshal Recommended for adoption by the Statewide Training and Education Advisory Committee and the State Board

More information

APPARATUS DRIVER / OPERATOR PUMPER

APPARATUS DRIVER / OPERATOR PUMPER Utah Fire Service Certification System APPARATUS DRIVER / OPERATOR PUMPER CERTIFICATION STANDARD MARCH 2015 ii Utah Fire Service Certification Council Chairperson Scott Spencer, Chief Payson Fire Department

More information

Rapid Intervention Crews. 11 Skills Total

Rapid Intervention Crews. 11 Skills Total Rapid Intervention Crews 11 Skills NFPA 1407, Training Fire Service Rapid Intervention Crews, 2015 Edition Updated Skill 2 - September 2017 1 Rapid Intervention Crews Skill Sheets JPR NFPA 1407 Task: Rapid

More information

FSRS Relative Point Value Guide

FSRS Relative Point Value Guide FSRS Relative Point Value Guide Note: This document has been produced by PIAL as a "guide" to show each 's impact to your total score. Certain ideal scenarios were assumed to determine the score in the

More information

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION Monroe Fire Department Standard Operating Guidelines Drivers Clearance & Training Program Guidance ADMINISTRATION Goal: to develop and maintain a force of driver-operators and ensure they are proficient

More information

2017 Volunteer Week - Course Descriptions

2017 Volunteer Week - Course Descriptions 2017 Volunteer Week - Course Descriptions 40 Hour Course - S130/S190/L180 Introduction to Wildland Firefighting S190 This course provides instruction in the primary factors affecting the start and spread

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

Firefighter Code of Ethics

Firefighter Code of Ethics Fire Apparatus Driver/Operator Pumper Certification Preparation Guide June, 2016 Firefighter Code of Ethics I understand that I have the responsibility to conduct myself in a manner that reflects proper

More information

ENGINE 260 REVISED

ENGINE 260 REVISED ENGINE 260 REVISED - 2018-1- TABLE OF CONTENTS General Rules... 3-4 Event Rules Ladder Climb... 5 Tug-O-War... 7 Lakeside Draft Motorized... 7 Hand Pumpers... 8 Midnight Alarm... 9 Water Barrel... 10 Arena

More information

PUMP OPERATIONS SAN FRANCISCO FIRE DEPARTMENT

PUMP OPERATIONS SAN FRANCISCO FIRE DEPARTMENT PUMP OPERATIONS SAN FRANCISCO FIRE DEPARTMENT Blank page Pump Operations January 2008 San Francisco Fire Department 698 2 nd Street San Francisco, CA 94107 Chief of Department Joanne Hayes-White Manual

More information

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR VOLUME XIV, ISSUE 1 FIRE HOSE AND NOZZLES JANUARY 1993 FIRE HOSE AND NOZZLES This is a two-part lesson covering Fire Hose and Nozzles.

More information

PERFORMANCE CRITERIA AND INSTRUCTIONS

PERFORMANCE CRITERIA AND INSTRUCTIONS JPR Task(s): Roll Fire Hose OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 1 OMPETENY EVALUATION andidate #: Skill No. 1-31 PERFORMANE RITERIA AND INSTRUTIONS

More information

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA PROPERTY INSURANCE ASSOCIATION OF LOUISIANA WATER HAULING GUIDELINES NOTE: Effective immediately, Fire Departments in Louisiana who receive credit for water hauling will receive their credit through a

More information

COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION COMMONWEALTH OF KENTUCKY FIREFIGHTER 2 COMPETENCY EVALUATION

COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION COMMONWEALTH OF KENTUCKY FIREFIGHTER 2 COMPETENCY EVALUATION OMMISSION ON FIRE PROTETION PERSONNEL STANDARDS AND EDUATION OMMONWEALTH OF KENTUKY FIREFIGHTER 2 OMPETENY EVALUATION JPR Task(s): Establish Incident ommand and oordinate Interior Attack of a Structure

More information

Idaho Fire Service Technology Fire Fighter II

Idaho Fire Service Technology Fire Fighter II ICS Skill Requirements Skill Sheet: 1 STANDARD: 6.1.2 TASK: Organize, coordinate, and function within an incident management system. PERFORMANCE OUTCOME: The candidate shall be able to determine the need

More information

FIREFIGHTER II. STUDENT Task Book. Agency/Department:

FIREFIGHTER II. STUDENT Task Book. Agency/Department: FIREFIGHTER II STUDENT Task Book Agency/Department: Bring this completed PTB to test location to have it reviewed by GFSTC s test proctor, along with a signed prerequisite form. FAILURE TO DO THIS WILL

More information

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 5 TOPIC: SUPPLY LINES AND SALVAGE LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED

More information

**ALL SHADED SKILLS MUST BE SIGNED OFF BEFORE LIVE FIRE TESTING MAY OCCUR**

**ALL SHADED SKILLS MUST BE SIGNED OFF BEFORE LIVE FIRE TESTING MAY OCCUR** UTAH FIRE SERVICE CERTIFICATION SYSTEM FIREFIGHTER I NFPA 1001, 2013 Edition FIREFIGHTER I TRAINING RECORD / IN-HOUSE COMPREHENSIVE EXAM NAME: DEPARTMENT: **ALL SHADED SKILLS MUST BE SIGNED OFF BEFORE

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

Northeastern Illinois Public Safety Training Academy. Course Syllabus 103

Northeastern Illinois Public Safety Training Academy. Course Syllabus 103 Northeastern Illinois Public Safety Training Academy Course Syllabus 103 Title: Fire Apparatus Engineer Type: Campus Training Program (CTP) Program Duration: 48 Hours Coordinator: B. Hatch Course Description

More information

Emergency Vehicle Driver

Emergency Vehicle Driver Emergency Vehicle Driver Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/Operator Professional Qualifications, 2014 Edition. Alabama Fire College February 2016 0 /09/2017 Alabama

More information

Rescue Technician: Confined Space Rescue I/II

Rescue Technician: Confined Space Rescue I/II Rescue Technician: Confined Space Rescue I/II Skill Sheet Package Based on NFPA 1006: Standard for Technical Rescue Professional Qualifications, 2013 Edition. Alabama Fire College June 2014 REVISED 02/10/2017

More information

second test was conducted using at 3/4inch nozzle to determine a practical maximum pressure for the pump.

second test was conducted using at 3/4inch nozzle to determine a practical maximum pressure for the pump. I am writing this memo to you from the perspective of a fire apparatus operator and tester. Though I offer this collection of my observations and opinions, I do so voluntarily but with the full integrity

More information

E X T E R I O R L I V E P R O P A N E F I R E P R O P P R O C E D U R E S F O R U S I N G T H E P R O P A N E P R O P

E X T E R I O R L I V E P R O P A N E F I R E P R O P P R O C E D U R E S F O R U S I N G T H E P R O P A N E P R O P E X T E R I O R L I V E P R O P A N E F I R E P R O P Gina Gonzales Created: July 11, 2016 Version 1 NFPA 1403 P R O C E D U R E S F O R U S I N G T H E P R O P A N E P R O P Prior to using any of the

More information

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker:

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker: Section I: Apparatus Knowledge The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus. 1. The Apparatus Driver/Operator demonstrates

More information

CITY OF CHICAGO FIRE DEPARTMENT FIRE ENGINEER PROMOTIONAL PROCESS STUDY GUIDE UPDATE FOR THE PROFICIENCY TEST

CITY OF CHICAGO FIRE DEPARTMENT FIRE ENGINEER PROMOTIONAL PROCESS STUDY GUIDE UPDATE FOR THE PROFICIENCY TEST CITY OF CHICAGO FIRE DEPARTMENT FIRE ENGINEER PROMOTIONAL PROCESS STUDY GUIDE UPDATE FOR THE PROFICIENCY TEST December 15, 2016 NOTICE: A limited license is granted by the City of Chicago only to individual

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Tank Distribution System A-UPT Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.2 Warnings and Cautions... 1 1.2 Theory of Operation...

More information

Rescue Technician: Cave Rescue I/II

Rescue Technician: Cave Rescue I/II Rescue Technician: Cave Rescue I/II Skill Sheet Package Based on NFPA 1006: Standard for Technical Rescue Professional Qualifications, 2013 Edition. Alabama Fire College August 2014 REVISED 02/10/2017

More information

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus.

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus. Section I: Apparatus Knowledge The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus. 1. The Apparatus Driver/Operator demonstrates

More information

Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet

Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet Full Name: Fire Department: This Instructional JPR Verification Sheet is to be used in conjunction with the Alabama Fire

More information

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system.

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system. Water Supply - 1 UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system. 2. Identify the causes of increased resistance

More information

Flow Material Length. Weight GPM LPM. Style 3095

Flow Material Length. Weight GPM LPM. Style 3095 Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi

More information

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL I-867-4T 867-4T Pressure Reducing Valve HANG THESE INSTRUCTIONS ON THE INSTALLED VALVE FOR FUTURE REFERENCE WARNING Read and understand all instructions

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 21a 1. Description With Multiple Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple deluge foam risers can be supplied from a single foam concentrate source. Where a bladder

More information

Piped Air SCBA Refilling System Standard

Piped Air SCBA Refilling System Standard WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Piped Air SCBA Refilling System Standard SCOPE: This specification

More information

DRIVER/OPERATOR - PUMPER NFPA 1002

DRIVER/OPERATOR - PUMPER NFPA 1002 DRIVER/OPERATOR - PUMPER NFPA 1002 The following lesson plans for Apparatus Driver/Operator - Pumper are based on NFPA 1002, Standard for Fire Department Vehicle Driver/Operator Professional, 1993 Edition.

More information

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Chapter 16 Test. Directions: Write the correct letter on the blank before each question. Chapter 16 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Explain the way vaporization and steam relate to the extinguishing properties of water.

More information

Student Workbook SW2. Fireground Support operations

Student Workbook SW2. Fireground Support operations WRITTEN AND PRACTICAL EXERCISES FOR USE WITH Fireground Support operations Issued To This Student Workbook Is Compatible With ARIZOFT Courses FSCBL2 and PPP-2 TM Arizoft Software Copyright 2003 Arizoft

More information

Topic: Forward Lay/Offensive Fire Attack Reference #: DG 16-6 orig Level of Instruction: In service personnel Time Required: 3 hours

Topic: Forward Lay/Offensive Fire Attack Reference #: DG 16-6 orig Level of Instruction: In service personnel Time Required: 3 hours Topic: Forward Lay/Offensive Fire Attack Reference #: DG 16-6 orig 14-08 Level of Instruction: In service personnel Time Required: 3 hours Instructor Preparation: This drill requires basic preparation

More information

===============================================================

=============================================================== TOPIC: TRAINING TECHNIQUES LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS REFERENCES: Fire and Emergency Services Instructor, 6 th ed., International

More information

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically

More information

TOPIC: EVALUATING FIREFIGHTER PROFICIENCY MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION

TOPIC: EVALUATING FIREFIGHTER PROFICIENCY MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION 1 MFRI Drill of the Month INSTRUCTOR GUIDE TOPIC: EVALUATING FIREFIGHTER PROFICIENCY LEVEL OF INSTRUCTION: TIME REQUIRED: SIX HOURS MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION

More information

Rescue Technician: Rope Rescue I

Rescue Technician: Rope Rescue I Rescue Technician: Rope Rescue I Skill Sheet Package Based on NFPA 1006: Standard for Technical Rescue Professional Qualifications, 2013 Edition. Alabama Fire College August 2016 REVISED 02/10/2017 Alabama

More information

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved

More information

2018 GEORGIA FIRE SERVICE CONFERENCE FIREFIGHTERS COMPETITION

2018 GEORGIA FIRE SERVICE CONFERENCE FIREFIGHTERS COMPETITION 2018 GEORGIA FIRE SERVICE CONFERENCE FIREFIGHTERS COMPETITION Friday, August 17, 2018 Dalton, Georgia OFFICIAL RULES & REGULATIONS Please review the following rules and regulations for the Georgia Fire

More information

Discharge Relief Valve Operation & Maint.

Discharge Relief Valve Operation & Maint. Relief Valve Operation & Maint. CZ Series Centrifugal Fire Relief svalve Operation and Maintenance Instructions 1410 Operation and Maintenance Form No. F-1031 Section 2302.6 2111 Issue Date 04/90 11/95

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 31a 1. Description With Multiple Pilot Pressure Regulating Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple pilot pressure regulating foam risers can be supplied from

More information

OBSOLETE. Wet pipe low flow manifold system

OBSOLETE. Wet pipe low flow manifold system June 1, 2008 Foam 15a 1. Description Multiple risers can be supplied from a single proportioning device. A riser manifold is installed with various riser types and sizes that are to supply foam solution

More information

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 SUPPLEMENT 101 101. HIGH PRESSURE FIRE HYDRANT SYSTEM The High Pressure

More information

Poudre Fire Authority Driver/Operator Manual Third Edition March 2006

Poudre Fire Authority Driver/Operator Manual Third Edition March 2006 Poudre Fire Authority Driver/Operator Manual Third Edition March 2006 Copyright 2006 Poudre Fire Authority Fort Collins, Colorado http://www.poudre-fire.org Introduction ii Introduction Table of Contents

More information

SKILL VERIFICATION BOOK FIREFIGHTER I MODULE I FIRE PROTECTION BUREAU. Assigned to: Name:

SKILL VERIFICATION BOOK FIREFIGHTER I MODULE I FIRE PROTECTION BUREAU. Assigned to: Name: Assigned to: Name: Skill Book Initiated: Department/District: Identification Number: SKILL VERIFICATION BOOK FIREFIGHTER I MODULE I Third Edition September 2004 Meeting the requirements of NFPA 1001, 2002

More information

Wilton Fire Protection District. TRAINING DIVISION New apparatus

Wilton Fire Protection District. TRAINING DIVISION New apparatus Wilton Fire Protection District TRAINING DIVISION New apparatus OPERATIONAL SIGN-OFFS 3/05 OPERATIONAL SIGN-OFF PACKET To: ALL PERSONNEL The purpose of this Operational Sign-off Packet is to provide all-line

More information

State of Oregon Department of Public Safety Standards and Training. Driver Task Book. Task Book Assigned To:

State of Oregon Department of Public Safety Standards and Training. Driver Task Book. Task Book Assigned To: State of Oregon Department of Public Safety Standards and Training Driver Task Book Task Book Assigned To: Name DPSST Fire Service # Department Name Date Initiated Signature of Department Head or Training

More information

KILGORE FIRE DEPARTMENT

KILGORE FIRE DEPARTMENT Page 1 of 13 KILGORE FIRE DEPARTMENT Operations/ SOP Directive Issue Date: 01/01/2013 237 Effective: 01/01/2013 COMPANY PERFORMANCE STANDARDS 237.1 Purpose The purpose of this procedure is to define and

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

Industrial Fire Brigade: Interior Structural

Industrial Fire Brigade: Interior Structural Industrial Fire Brigade: Interior Structural Skill Sheet Package Based on NFPA 1081: Standard for Industrial Fire Brigade Member, 2012 Edition. Alabama Fire College May 2014 Certification Criteria Interior

More information

Upon completion of this unit of study, the student should be able to: 1. Identify the term fire stream and the four purposes of a fire stream.

Upon completion of this unit of study, the student should be able to: 1. Identify the term fire stream and the four purposes of a fire stream. UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: 1. Identify the term fire stream and the four purposes of a fire stream. 2. Identify the advantages and disadvantages

More information

Volunteer Firefighter Applicant Information Package

Volunteer Firefighter Applicant Information Package Volunteer Firefighter Applicant Information Package INTRODUCTION TO THE KINGSVILLE FIRE DEPARTMENT The Kingsville Fire Department provides emergency fire and rescue service to the residents of the Town

More information

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE PACIFIC LIQUID & AIR SYSTEMS WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE IN THE BEGINNING Before installing or operating this system, familiarize yourself with these instructions. You should

More information

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE October 21, 2010 Pumping Systems for Landscaping Pumps, Controls and Accessories Mark Snyder, PE Pump Station Design Purpose of Pump Stations Pump stations are designed to boost water pressure from a lower

More information

CONCENTRATE CONTROL SYSTEM

CONCENTRATE CONTROL SYSTEM CONCENTRATE CONTROL SYSTEM OPERATING, MAINTENANCE, AND FILLING MANUAL Vertical And Horizontal Bladder Tanks October, 2006 Trusted Above All TM www.vikinggroupinc.com TABLE OF CONTENTS CCS Cut-Away Drawing...1

More information

NEVADA STATE RAILROAD MUSEUM

NEVADA STATE RAILROAD MUSEUM NEVADA STATE RAILROAD MUSEUM Carson City, Nevada HOSTLER HELPER HANDBOOK 2010 Hostler Helper Description: A Hostler Helper is a volunteer who is an assistant to the Hostler. He is responsible to and assists

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

Fire Fighter I Skill Station Menu NFPA Edition

Fire Fighter I Skill Station Menu NFPA Edition Fire Fighter I Skill Station Menu Station A SCBA OPERATIONAL CHECK MANDATORY STATION Station B SCBA DONNING MANDATORY STATION Station C PRIMARY SEARCH AND UTILITY CONTROL MANDATORY STATION Station D SCBA

More information