IFP C175-* REMOTE CONTROL RELIEF VALVE

Size: px
Start display at page:

Download "IFP C175-* REMOTE CONTROL RELIEF VALVE"

Transcription

1 IFP C175-* REMOTE CONTROL RELIEF VLVE Low Pressure Differential Quiet Operation Easy to djust Handle Three Pressure Ranges vailable Panel Mount Design P T Model Pressure Range (PSI) Rated Flow (US GPM) C175 - * C PSI 5 US GPM C PSI 5 US GPM C175-C PSI 5 US GPM REMOTE CONTROL RELIEF VLVE IFP C175 * MODEL 1/4 - NPT THRED PRESSURE RNGE PSI PSI C PSI IFP offers a direct acting spring loaded relief for applications requiring a remote control relief valve for pilot operation of variable volume pumps and balanced piston type relief valve.

2 IFP C175 THREDED RELIEF VLVE INSTLLTION DIMENSIONS Dimension (inches) 0.27" Dia Tru. 0.43" c'bore 0.25" deep 4 holes for mounting 2.25 C 3.07 Dia fully extended.5.05 Tank connection 1/4 NPT Thd Tank connection 1/4 NPT Thd Dia. Pressure inlet connection 1/4 NPT Thd.

3 IFP RELIEF VLVES 3000 PSI/LNCED PISTON TYPE High Flow Low Pressure Differential Quiet Operation/No Chatter Optional Vent & Remote Port Connection Three Pressure Ranges vailable Gauge Port Standard P C:\wliu\CT10.bmp Gauge P Vent Model Pressure Range (PSI) Rated Flow (US GPM) Rated Flow (US GPM) C * 06 C * 10 C * PSI 60 US GPM 120 US GPM C * PSI 60 US GPM 120 US GPM C * - C PSI 60 US GPM 120 US GPM T COMPOUND RELIEF VLVE IFP C* 06 MODEL T- NPT THRED S-SE THRED G- SUPLTE MTG (CG06 ONLY) (SPT VILLE) 06 - VLVE SIZE 3/4" 10- VLVE SIZE 1 1/4" PRESSURE RNGE PSI PSI C PSI IFP offers a balanced piston relief valve designed for use in applications requiring an adjustable regulating valve to limit the pressure in a hydraulic circuit to a predetermined maximum. The relief valve consists of a control poppet and main spool which provides low pressure differential and quiet operation. Pressure can be adjusted by loosening a jam nut and turning the adjustment knob. Turning clockwise increases pressure. Vent port is provided for remotely controlling or venting the relief valve.

4 IFP CT06/CS06 THREDED RELIEF VLVE INSTLLTION DIMENSIONS DIMENSION (inches) GUGE PORT SECTION - L SPRING see table I SPRING Table K Code Part number Pressure J L PSI PSI C PSI VENT PORT H PRESSURE G PRESSURE C F E D TNK MODEL C D E F G H I J K L CT/S PORTS - 3/4 NPTF / STRIGHT THRED

5 IFP CG-06 SUPLTE RELIEF VLVE INSTLLTION DIMENSIONS Dimension (inches) SPRING see table D SPRING Table C Code Part number Pressure PSI PSI C PSI VENT PORT I J GUGE PORT F E G H MODEL C D E F G H I J CG O.66

6 IFP CT10/CS10 THREDED RELIEF VLVE INSTLLTION DIMENSIONS DIMENSION (inches) Vent connection UNF-2 str. thd O.D tubing Pilot or pressure gauge connection (if required) unf-2 str. thd..250 O.D tubing SPRING Table Code C Part number Pressure PSI PSI PSI SPRING see table 4.75 K-SYSTEM CONNECTION 3 PLCE 2.08 F PRESSURE P P PRESSURE C T D 6 Dia. 3 Place TNK H E Model series C D E F G H I J CT/S P - System Connections CS - 10 Models CT - 10 Models UN - 2 Thd. (1.250 O. D Tubing ) 1 1/4 NPTF Thread.

7

8

9

10

11 IFP CHECK VLVES 3000 PSI working pressure Optional cracking pressures Steel poppet eliminate chatter Free flow one direction Shut-off reverse direction Mounting position of valve not limited L Model DTP 03 DTP 04 DTP 06 DTP 08 DTP 10 PORTS 3/8" NPTF 1/2" NPTF 3/4" NPTF 1" NPTF 1-1/4" NPTF L Ordering Code IFP DTP 03 SERIES IN LINE THRED TYPE DTP (NPT) DTS (SE) CRCKING PRESSURE 5 PSI 30 PSI VLVE SIZE C 70 PSI 03-3/8" 04-1/2" 06-3/4" 08-1" /4"

12 IFP FLOW CONTROL VLVES Designed for extremely precise control of air and hydraulic fluids Max pressure 5000 PSI ll metal construction Micrometer knob with easy to read colour bands Temperature -20 F to 400 F I5.1

13 IFP NEEDLE VLVES 3000 PSI working pressure Leak-free shut-off Panel mount hardware standard Fine Metering djustments can be made under pressure PRT No. THRED H Pressure Flow NVI-02 1/4" N.P.T PSI 5 GPM NVI-03 NVI-04 3/8" N.P.T 1/2" N.P.T PSI 8 GPM 5000 PSI 15 GPM NVI-06 3/4" N.P.T PSI 25 GPM H FLOW Designed for use with air, oil, water, steam, liquid fuel & most chemicals.

14 IFP "FC" Variable Flow Control Pressure Compensated New Product 2009 (CF) FC51 (EX) (CF) FCR51 (EX) (INLET) (CF) FC55 (INLET) (EX) (INLET) IFP FC & FCR pressure compensated variable flow control valves operate by controlling the controlled flow orifice area from zero to maximum flow with the rotation of the adjustable lever to a specific flow increment. Excess flow is supplied out the excess port on the valve, and the sum of the controlled flow and excess flow is equal to the input flow. oth the controlled flow and excess flow are pressure compensated and provide smooth constant outlet flow regardless of the pressure on the CF and EX ports. IFP FCR has the added feature of an adjustable ball spring relief on the controlled flow to limit the maximum working pressure of the CF controlled flow. IFP FC55 incorporates reverse free flow checks allowing cylinders and motors to operate in reverse. Flow can can be reversed from either the EX or CF ports bypassing the metering function to the inlet of the valve IFP FC R P - N Relief: Port Type: Omit - No Relief P - NPT Thread R- all spring Relief S -SE O Ring Thread ( Factory set 1500 PSI / dj PSI) Flow Path: 51 - Standard Flow Control 55 - Free reverse flow (Not available FC*R* feature) Port Size: NPT : 04-1/2 NPT (0-16 GPM) 06-3/4 NPT (0-30 GPM) SE: 05 - SE- #10 (0-16 GPM) 06 - SE- #12 (0-30 GPM)

15

16 PRESSURE SWITCHES Micrometer adjustment Three pressure ranges Low differential Compact design C:\wliu\PS.bmp I 7.1

17 PRESSURE SWITCHES I 7.2

18 NC NO PRESSURE SWITCHES SW FETURES: - Economical - High Pressure Ratings - Wide djustment Range - Low Differential - Graduated Micrometer djustment - Compact Design - Locking nut for panel mount PPLICTIONS: - utomated Circuit Control - System larm - Pilot Light ctivation - System Overload Protection NC (0.93) 2 1 NO 6 (0.24) 2 M4x0.7 m P m Locking nut 38 (1.50) 0.25`` NPT Thread 35 (1.38) MODEL P-03 C V./3. MFG. No. 43 (1.69) MX 77 (3.03) 85 (3.35) 43 (1.69) 123 (4.84) 148 (5.83) Model Valve Size Pressure Range Pressure Differance Electrical Rating SW /4'' PSI at 400 PSI: PSI at 5000 PSI: PSI DC 24V C V/3

19 IFP IR LEED VLVES Removes air trapped in Hydraulic system Operating pressure to 5000 PSI (Non stock service) Facilitate pump priming at start up IN OUT Model No T20S Port Sizes 3/8" NPT IFP ir leed Valves are used to remove trapped air in a hydraulic circuit or facilitate pump priming at start up when operating in a closed circuit. Unit operates by allowing air to pass at low pressure (start up) to the tank and oil flow will be closed as pressure increases. Note:- ir leed should be installed as close as possible to pump outlet in a vertical position. ir leed return line should be terminated below oil level in the reservoir.

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

Lesson 6: Flow Control Valves

Lesson 6: Flow Control Valves : Flow Control Valves Basic Hydraulic Systems Hydraulic Fluids Hydraulic Tank Hydraulic Pumps and Motors Pressure Control Valves Directional Control Valves Flow Control Valves Cylinders : Flow Control

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed

More information

P.C. Flow Regulator Valve Series FR101. General Description

P.C. Flow Regulator Valve Series FR101. General Description P.C. Flow Regulator Valve Series FR11 Compensated Flow Regulator Valve. NOTE: When used with a fixed displacement pump, pressure to the cartridge must be controlled by a relief valve located between the

More information

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders ENGINEERING DT PV Piston Pumps Same Day Shipments of Units or Part Orders Interchangeable Parts Fully Tested w w w. F l u i D y n e F P. c o m Email:cs@FluiDyneFP.com Contents asic characteristics.........................................................................................

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001 Xpress L90LS Directional Control Valve Catalog HY17-8525/UK December, 2001 Catalogue HY17-8525/UK Technical Information Xpress - general information Xpress is a valve-customization service that enables

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Standard Operating and Maintenance Instructions for Pumping System Model PS-150 Standard Operating and Maintenance Instructions for Pumping System Model PS-150 High Pressure Equipment Company, LLC 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page CP20-2 PRC 06 SDC10- NCS06/ Pressure Reducing, Non-Relieving, Direct Acting 40 l/min [10 US gal/min] 40 l/min

More information

SO 9001 I ACCESSORIES

SO 9001 I ACCESSORIES ISO 9001 ESSORIES ESSORIES INDEX Page In-Line Mounted Flow ontrol Valves 3 In-Line Mounted heck Valves 3 Quick Exhaust, heck and Shuttle Valves In-Line Ported Lockout Valves 5 Mufflers 6 Fittings 7-9 2

More information

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve Model CYCLE GARD II, CI & CNA YOUR PRODUCT INFORMATION: Model Number: Date: Serial Number:

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

PTS1120TSJB PTS2120TSTSJB

PTS1120TSJB PTS2120TSTSJB Engineering & Manufacturing Solutions Specifications: 18 gpm (68.0 lpm) Nominal Capacity. Rated up to 3000 psi (207 bar). Port Sizes: -Inlet/Outlet #12 SAE. -Work Ports #10 SAE. 10 Micron Filtration Recommended.

More information

Introduction. Part one: Identify the Hydraulic Trainer Components

Introduction. Part one: Identify the Hydraulic Trainer Components The University Of Jordan School of Engineering Mechatronics Engineering Department Fluid Power Engineering Lab Experiments No.4 Introduction to Hydraulic Trainer Objective: Students will be able to identify

More information

Pressure Reducing Valves Catalog Quick Reference

Pressure Reducing Valves Catalog Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page 2 CP20-2 SDC0- Pressure Reducing, 20 bar PR - 5 PRC 06 NCS06/ Non-Relieving, Direct Acting [000 psi] 5 bar [4500

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information

MDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB

MDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB Engineering & Manufacturing Solutions Specifications: MDC rated for -4 gpm (-151 lpm) MDCF rated for -3 gpm (-114 lpm) Rate for 3 PSI (27 bar) Port Sizes #16 SAE (1-5/16-12) all ports Weighs 16 lbs. (7.3

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

SystemStak Valves. ISO4401 Size 02

SystemStak Valves. ISO4401 Size 02 SystemStak Valves ISO441 Size 2 Reduce System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and

More information

High Pressure Check Valves

High Pressure Check Valves High Pressure heck Valves Pressures to 60,000 psi (4137 bar) O-Ring heck Valves Minimum operating temperature for standard o-ring check valves 0 F (-17.8 ). For low temperature option to -423 F (-252 )

More information

Priority (Swing) Motors Data and Specifications

Priority (Swing) Motors Data and Specifications s Data and Specifications Specifications HMF 55 HMF 75 HMF 105 cm 3/rev in 3/rev 55 3.36 75 4.57 105 6.40 Pressure Ratings Nominal 5000 PSIG Maximum 6090 PSIG Peak 7250 PSIG Operating Speed Maximum 4100

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Load and Motor Control Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD PILOT ASSISTED CB101... C10-3... Load Control Cartridge Valve...45/12... 380/5500... 5-6 MHC-010-S***

More information

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

Chapter 10: Bidirectional Flow Controls

Chapter 10: Bidirectional Flow Controls Chapter 10: Bidirectional Flow Controls Objectives Learn about the patented, bidirectional flow control valves. Understand how the flow force affects the performance of the ZL70-36. Learn why there is

More information

Pressure Reducing Control Valve w/ Hydraulic Check Feature

Pressure Reducing Control Valve w/ Hydraulic Check Feature PERTIN INSTRUTINS peration The BEE Model PR- Pressure Reducing ontrol alve with Hydraulic heck eature is a pilot controlled diaphragm valve designed to reduce a fluctuating higher upstream pressure to

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description 4 Ω-1 Ω Series Proportional Electro-ydraulic This relief and flow control valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since this valve controls

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE

More information

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv CAT.ES-173 A Air Saving Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction ratio (%) 3 1.1.1...3 pressure

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

Operating Instructions Model and Hydrostatic Test Pump

Operating Instructions Model and Hydrostatic Test Pump Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data ir line equipment Miniature eneral Purpose egulators 7, (non-repairable) 7 Full flow gauge ports Snap action knob locks pressure setting when pushed in Standard relieving models allow reduction of outlet

More information

Techcon Systems TS1254 Pressure Pot

Techcon Systems TS1254 Pressure Pot Techcon Systems TS1254 Pressure Pot User Guide Copyright OK International, Inc. TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. FEATURES. 5 3. SPECIFICATIONS 4 4. INSTALLATION

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual 10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured

More information

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS Muncie Power Products, Inc. TABLE OF CONTENTS DESCRIPTION PAGE Features... 3 Hydraulic

More information

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting REDUING (ND HEK) VLVES RT/RG RT/RG -3// (3/8, 3/, -/) Threaded onnections / Mounting Up to MPa (5 PSI), 5 L /m in (3 U.S.GPM) Pub. E-3 Pressure Reducing Valves Pressure reducing valves are used to set

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Air Saving Valve. Pressure Valve Flow Valve

Air Saving Valve. Pressure Valve Flow Valve Air Saving Valve Series Series Pressure Valve Flow Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich

More information

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter LINDGREN-PIAN, INC. LS-3 / LS-4 Line Setter MOUNTING The Lindgren-Pitman Line Setter should be mounted on or near the transom of the boat such that the line will fall overboard as it leaves the exit. The

More information

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar) Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar) The quickest and most economical way to perform pneumatic field pressure calibrations on pressure transmitters, switches

More information

Inert Air (N2) Systems Manual

Inert Air (N2) Systems Manual INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS HF42407-07 and HF51912-09 Muncie Power Products, Inc. TABLE OF CONTENTS DESCRIPTION PAGE Features...

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE

MADILL 24.7 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE MADILL 24.7" SAW - 365 DEG. TILT-REXROTH VALVE DANGER DO NOT perform any adjustment on sawhead unless saw blade lock bolt and guard

More information

005 Series Modular Valves

005 Series Modular Valves 5 Series Modular Valves ype of Modular Valve Class Graphic Symbols age Solenoid Operated Directional Valve DSG-5- *** - * - ressure Control Valves Flow Control Valves Directional Control Valves Modular

More information

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website: 1.0 Inspection of the product upon receipt: On receipt of the product, visually inspect the item for any evidence of shipping damage. Please note shipping damage is not covered by warranty. If shipping

More information

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012 Basic Pneumatics Module 8: Pressure control valves PREPARED BY Academic Services April 2012 Applied Technology High Schools, 2012 Module 8: Pressure control valves Module Objectives After the completion

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise

More information

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21 E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21 Table of Contents Introduction......................................................................................................

More information

Models: C62/63/64-A/D

Models: C62/63/64-A/D Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial

More information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze

More information

Proper Pump Installation Practices

Proper Pump Installation Practices Proper Pump Installation Practices 80-779, Rev. 10/08 There is a Reason Every Unit Comes With This Bright Orange Tag! Proper Alignment and Coupling Installation Do Not Drive Coupling Onto Shaft Pump Alignment

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

Series 1, 3 and 4 Cv = /8 and 1/4 Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position Cv =.52 -.73 Series, 3 and 4 Cv =.52.3 /8" and /4" Ported Manually Operated Valves 3-way/2-position, 5-way/2-position and 5-way/3-position Ports /8 and /4" NPTF The Series (/8 & /4", 3-way/2-position and

More information

HP/UHP Spring-Loaded Regulator

HP/UHP Spring-Loaded Regulator Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

F l o w c o n T R o l v a l v E S

F l o w c o n T R o l v a l v E S Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,

More information

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED] Lecture 19 PRESSURE-CONTROL VLVES [CONTINUED] 1.5 Counterbalance Valve Schematic diagram of counterbalance valve is shown in Fig. 1.14. These normally closed valves are primarily used to maintain a back

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

Cover headline. Cover subheadline. Check Valves

Cover headline. Cover subheadline. Check Valves Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December

More information

Copyright, 2005 GPM Hydraulic Consulting, Inc.

Copyright, 2005 GPM Hydraulic Consulting, Inc. Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

TEST BENCH FOR SAFETY VALVES

TEST BENCH FOR SAFETY VALVES TEST BENCH FOR SAFETY VALVES 1) Hydro panel : This Panel possesses This Bench Contains One Panel and One Reservoir. 1 No. Monobloc Version : Single Phase AC, 50 Hz Type of Duty :S1 (Continuous) Class of

More information