SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:
|
|
- Beverly Stanley
- 6 years ago
- Views:
Transcription
1 Catalog HY14-255/US Technical Information General Description sandwich type pressure s are typically used in combination with proportional directional control valves. The keeps the pressure drop over the directional valve constant and thus provides load-independent flow to the actuator. Features 2-way or 3-way pressure s. Standard pressure differential 5 ar (73 ). Adjustable differential (2 to 5 ar) (29 to 73 ) and 1 ar (145 ) optional. Sizes: NG6 / CETOP 3 NG1 / CETOP 5 NG16 / CETOP 7 NG25 / CETOP 8 SPC1 SPC2 SPC3 SPC4 SPC*1 (2-way) SPC*1/2 (3-way) SPC*1/2 (2-way) Specifications General Size NG6 NG1 NG16 NG25 ounting Interface ounting Position Ambient Temprature Hydraulic DIN 2434 A6 ISO 441 NFPA D3 CETOP 3 Unrestricted -2 C to +5 C (-4 F to +122 F) ax. Operating P, A, : Drain Port L Connected: Without Drain Port: 35 ar (575 ) T: 21 ar (345 ) L: 1 ar (145 ) P, A, : 35 ar (575 ) T: 16 ar (232 ) L: 16 ar (232 ) DIN 2434 A1 ISO 441 NFPA D5 CETOP 5 P, A, : 315 ar (4568 ) T: 21 ar (345 ) L: 1 ar (145 ) P, A, : 315 ar (4568 ) T: 21 ar (345 ) L: 21 ar (345 ) DIN 2434 A16 ISO 441 NFPA D7 CETOP 7 DIN 2434 A25 ISO 441 NFPA D8 CETOP 8 P, A,, X: 35 ar (575 ) T, Y: 15 ar (1523 ) P, A,, X: 35 ar (575 ) T, Y: 15 ar (1523 ) Nominal Flow 3 LP (7.9 GP) 8 LP (21.1 GP) 2 LP (52.9 GP) 4 LP (15.8 GP) Fluid Fluid Temperature Viscosity Permitted Recommended Hydraulic oil as per DIN , other on request -2 C to +8 C (-4 F to +176 F) 1 to 65 cst / mm 2 /s (46 to 313 SSU) 3 to 8 cst / mm 2 /s (139 to 371 SSU) Filtration ISO 446 (1999) 18/16/13 (acc. NAS 1638: 7) SPC3/6 (3-way) SPC3/6 (2-way) 111
2 Catalog HY14-255/US Ordering Information SPC 1 C 5 A Direct Operated Compensator Size Function Differential Circuit Load Sensing Port Steel ody Design Series Seal 1 NG6 2 NG1 1 3-Way Compensation 11 2-Way Compensation 4* 2 to 5 ar (29 to 73 ) Adjustable 5 5 ar (73 ) 1* 1 ar (145 ) * For 3-way only. 1 Nitrile 5 Fluorocarbon Weight: 2-Way Compensator 3-Way Compensator SPC1 1.5 kg (3.3 lbs) 1.6 kg (3.5 lbs) SPC2 3.1 kg (6.8 lbs.) 3.5 kg (7.7 lbs.) SPC1 odel No. SPC1141C5A1 SPC1151C5A1 SPC1111C5A1 SPC2 odel No. SPC2141C5A1 SPC2151C5A1 SPC2111C5A1 SPC11151C5A1 SPC21151C5A1 SPC C Direct Operated Compensator Size Function Pilot Connection Differential Load Sensing Port Design Series Seal 3 NG16 6 NG25 Code P X Description Internal Pilot External Pilot 5 5 ar (73 ) Standard 1* 1 ar (145 ) 1 Nitrile 5 Fluorocarbon 1 3-Way Compensation 11 2-Way Compensation Weight: SPC3 SPC6 8.3 kg (18.3 lbs) 11.9 kg (26.2 lbs.) SPC3 odel No. SPC31P5C1 SPC31X5C1 SPC311P5C1 SPC311P1C1 SPC311X5C1 SPC311X1C1 SPC6 odel No. SPC61P5C1 SPC61X5C1 SPC611P5C1 SPC611P1C1 SPC611X5C1 SPC611X1C1 112
3 Catalog HY14-255/US Performance Curves SPC1 Flow Regulation 2-Way Compensator at Dp = 5 ar ppump a b D1FW with 3 LP (7.9 GP) spool pload SPC2 Flow Regulation 2-Way Compensator at Dp = 5 ar D3FW with 8 LP (21.2 GP) spool a b ar = p Pump -P load ar = p Pump -P load SPC3 Flow Regulation 2-Way Compensator at Dp = 5 ar a b D41F with 2 l/min spool SPC6 Flow Regulation 2-Way Compensator at Dp = 5 ar a b D91F with 4 l/min spool Command 1% 9% 8% 7% 6% 5% Command 1% 9% 8% 7% 6% 5% 5 4% % % 5 3% ar System A, ar System A, 113
4 Catalog HY14-255/US Dimensions Inch equivalents for millimeter dimensions are shown in (**) 2-Way Compensator SPC1 SPC2 1) Always connect L to tank when SPC1 T > 16 ar (232 ) SPC2 T > 21 ar (345 ) 3-Way Compensator SPC1 SPC2 1) Always connect L to tank when SPC1 T > 16 ar (232 ) SPC2 T > 21 ar (345 ) 114
5 Catalog HY14-255/US Dimensions 2-Way Compensator SPC3/SPC6 3-Way Compensator SPC3/SPC6 Inch equivalents for millimeter dimensions are shown in (**) SPC3 SPC6 115
Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US
Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR
More informationSandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve
Technical Information Series PRM General Description Series PRM reducing valves are used to regulate pressure, in one area of a circuit, below normal system pressure. This style valve is well suited to
More informationPRESSURE COMPENSATORS TECNORD
PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for
More informationFunction. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.
Catalog HY14-255/US echnical Information ilot Operated ressure Reducing Valves Series VMY*6 General Series VMY*6 valves consist of the main stage with valve spools and the pilot stage with the proportional
More informationBW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface
ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US
More informationL6090 (LC04M-CBL) - L6095 (LC04M-CBD)
or 3 way pressure compensated flow regulators L69 (LC4M-CBL) - L695 (LC4M-CBD) RE 1833-4 Edition:.16 Replaces: 7.1 Size 4 Series Maximum operating pressure 31 bar (45 psi) Maximum flow (-way) 1 l/min (3.
More informationManapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM
Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich
More informationPressure reducing valve, pilot operated, Model 3DR
RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features
More informationINVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:
direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting
More informationPressure reducing valve, direct operated, type DR 5 DP Huade América 1
Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, type DR 5 DP Size 5 up to 31.5MPa up to
More informationRE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.
Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines
More informationDouble throttle/check valve, Type Z2FS Series 30 Huade América 1
Double throttle/check valve, Type Z2FS Series 30 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Double throttle/check valve, Type Z2FS Series 30 Sizes 6 16 22 up to 31.5MPa up to 350
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min
More informationMOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE
TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates
More informationAxial piston pumps type PVC
www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise
More informationAxial piston pumps type PVC
www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low
More information4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...
4/3 Directional valve elements L8L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L8L1...(EDC-LV) RE 1831-17 Edition: 2.216 Replaces: 7.12 Size 6 Series Maximum
More informationAuxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998
Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min
More informationPressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)
Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series) Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, sandwich
More informationPilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1
Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size
More informationDirectional Controls
Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP
More informationLeak free Pipe Rupture Valve for Excavators
Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................
More information2-way flow control valve Model 2FRM 6
R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D
More informationdirectional control valve series cv691
directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages
More informationPressure relief valves
Pressure relief valves Type DV700 Features Direct operated valve High degree of pressure stability Safe operation Precise pressure adjustment Maximum pressure setting with lock nut Applications as cartridge
More informationPressure reducing valve, pilot operated
Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content
More informationDouble Pilot Operated Cartridge Check Valve, Size 8
Double Pilot Operated Cartridge Check Valve, Size 8 Q max = 7 l/min (19 gpm), p max = 35 bar (5 psi) pilot operated, two-stage, spring-closed cartridge-type poppet valve Compact design for cavity type
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is
More informationLogic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)
Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min
More informationLeak-Free Load-Control Valve SAE ½ psi flange
Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control
More informationMonoblock Directional Control Valve RMB 202
Monoblock Directional Control Valve RMB 202 Key valve features RMB 202 is a 2-section mono block valve, especially designed for front-end loaders. The valve is prepared for quick connecting couplings,
More informationCooler-Bypass Thermostat Valve, Size 16
Cooler-Bypass hermostat Valve, Size Q max = l/min, p max = bar emperature-controlled, integral relief function, various pressure settings available Description emperature-dependent bypass control Integral
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More information4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)
4/3 Directional valve elements L8_5 with proportional (ED-I) control and with or without LS connections L8_5 (ED-I) RE 1831-7 Edition: 2.21 Replaces: 7.12 7.212 Size Series Maximum operating pressure 31
More information1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type
Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing
More informationDigital directional & flow control valves D-DF(R)G
Digital directional & flow control valves D-DF(R)G Functional Symbols Model Code D-DFG- D-DFG-~ D-DFRG-/ D-DFG--C--- Digital directional & flow control valve Size Spool type (neutral position) : ll ports
More information3-Way Pressure-Reducing Cartridge, Size 2 4
-Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher
More informationThe Size 16 Product Range
Screw-in Cartridges, Sandwich Bodies, Line-ounting Bodies The Size 6 Product Range ulti-functional Compact Economical Pressure: Flow Rate: 40 bar 50 l/min An Introduction to the Size 6 Product Range according
More informationPressure-Relief Cartridge Valve, Size 4
Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure
More informationMDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB
Engineering & Manufacturing Solutions Specifications: MDC rated for -4 gpm (-151 lpm) MDCF rated for -3 gpm (-114 lpm) Rate for 3 PSI (27 bar) Port Sizes #16 SAE (1-5/16-12) all ports Weighs 16 lbs. (7.3
More informationPRESSURE SEQUENCE VALVE TYPE UZK
PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set
More informationFlow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve
Flow Control Valves Series MTK, MTQ, MTC MTQ... MTC... robust, uncomplicated, reliable these valves do not require maintenance. This lowers costs and reduces the risk of a system failure. can be provided
More informationLoad Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)
Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationCover headline. Cover subheadline. Check Valves
Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December
More informationCheck Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.
Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationCheck valve hydraulically pilot operated
Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents
More informationDirectional Controls
Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................
More informationDamcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04
Damcos PHP 25-05 Portable hand pump unit 5 l Product Data Sheet September 2014 SD 6601-2E04 TM Damcos PHP 25-05 September 2014 General description Double-acting portable hand pump incl. 5 l. reservoir
More informationDisplacement 12, , Maximum flow rate (at 1450 rpm) bar.
00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment
More informationPLD 03 T A CASAPPA S.p.A.
GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...
More informationL125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE
L15 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE TAKE CONTROL Take control with Muncie Power Products L15 directional control valve. The L15 is constructed with high-grade, iron castings and nickel-plated
More informationLeak-Free Load-Control Valve, Size 20
Leak-Free Load-Control Valve, Size 20 Qmax = 350 l/min [92 gpm], pmax = 420 bar [6000 psi] leak-proof, two-stage hydraulic, manifold mounting 20--P... 1 Description Whenever large loads are to be precisely
More informationHYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL
HYDRAULIC OORS APPLICAION» Skid Steer Loaders» etal working machines» renchers» Augers» Agricultural machines» Road building machines» Special vehicles» ine machines» Woodworking and sawmill machinery»
More informationSize 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K -
ase late with with ressure Relief Valve for Serial lates ssemblies Z0 Size 0 (D05) p max 320 bar (4600 SI) echnical Features ank cover mounted base manifold for hydraulic power packs which require one
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationInverse Proportional Pressure-Relief Cartridge, Size 10
Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size
More informationHYDRAULIC MOTORS MV APPLICATION GENERAL
HYDRAULIC V APPLICAION» Conveyors» etal working machines» Agriculture machines» Road building machines» ining machinery» Food industries» Special vehicles» Plastic and rubber machinery etc. CONENS Specification
More informationPilot Operated Check Valves Catalog Quick Reference
Quick Reference Pilot to Open Model No. Description Flow* Pressure Page RPC NCS/3 Pilot Operated Check Valve, Pilot to Open.5 l/min [5. US gal/min] RPC NCS/3 35 l/min [9.3 US gal/min] CP5- SDC-3 3 l/min
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationE 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when
More informationAxial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request
www.atos.com Table TA60obs/E Axial piston pumps type PVPY- (-R, -) variable displacement, with mechanical controls obsolete components - availability on request PVPY are variable displacement axial piston
More informationProportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
More informationVickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94
Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationE SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description
4 Ω-1 Ω Series Proportional Electro-ydraulic This relief and flow control valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since this valve controls
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationPressure Relief Valves. SPV, SPVF direct operated
Pressure Relief Valves SPV, SPVF direct operated Construction P Ø d 1 a T c 2 3 b 4 1 Housing 2 Sliding piston 3 Compression spring 4 Set screw Bleeding screw 6 Protective cap 6 Description The pressure
More informationVariable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design
Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary
More informationPressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)
Hydraulic Screw-in Cartridge Valves (SiCV) Pressure control Direct and pilot operated pressure control valves for applications up to 5 bar (5 psi) and L/min (8 USgpm) Pressure control PRSSUR CONTROLS...-4
More informationPTS1120TSJB PTS2120TSTSJB
Engineering & Manufacturing Solutions Specifications: 18 gpm (68.0 lpm) Nominal Capacity. Rated up to 3000 psi (207 bar). Port Sizes: -Inlet/Outlet #12 SAE. -Work Ports #10 SAE. 10 Micron Filtration Recommended.
More informationVSD03M DIRECTIONAL CONTROL VALVES
NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.
More informationFixed Displacement Pump KFA for commercial vehicles in open circuits
RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features
More informationP2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES
52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by
More informationCartridge Valves Technical Information. Pilot operated check valves. Quick reference
Quick reference Pilot to Open Model No. Description Flow* Pressure Page P RPC 4 NCS4/ Pilot Operated Check Valve, Pilot to Open l/min [ US gal/min] RPC 6 NCS6/ 5 l/min [7 US gal/min] CP45- SDC- l/min RPC
More informationXpress L90LS Directional Control Valve. Catalog HY /UK December, 2001
Xpress L90LS Directional Control Valve Catalog HY17-8525/UK December, 2001 Catalogue HY17-8525/UK Technical Information Xpress - general information Xpress is a valve-customization service that enables
More informationProportional Directional Valve System
roportional Directional Valve System Sectional Design and Flow Sharing rinciple Reference: 31--959-EN-3 Stand: 9.216 1/2 2/2 31--959-EN-3/9.216 Contents age 1 General... 5 1.1 Description... 5 1.2 Advantages...
More informationAuxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003
Auxiliary Valve Pressure Reducing Valve June 2003 General Subject to alteration without prior notice. The curves and diagrams in this catalogue are typical examples only. While the contents of the catalogue
More informationF05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK
CONTINENTAL HYDRAULICS F05MSV-N* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400
More informationPRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting
REDUING (ND HEK) VLVES RT/RG RT/RG -3// (3/8, 3/, -/) Threaded onnections / Mounting Up to MPa (5 PSI), 5 L /m in (3 U.S.GPM) Pub. E-3 Pressure Reducing Valves Pressure reducing valves are used to set
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed
More informationMonoblock directional control valves ML - Directional control valve
Monoblock directional control valves ML - Directional control valve ML Before use, carefully read the GENERAL INSRUCIONS FOR USE OF DIRECIONAL CONROL VALVES 398SMD4I - 6--8 ML echnical data Nominal flow
More informationDNS. Monoblock directional control valves DNS - Directional control valve
Monoblock directional control valves DNS - Directional control valve DNS efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES 398SMD6I - 6--8 DNS echnical data Nominal flow
More informationSDM to 8 sections monoblock valve D1WWDA02A
SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information
More informationR S 280 is a modular parallel sect. Directional Control Valve RS RS In relation to its flow capacity its installation
Directional Control Valve RS 280 3 RS 2802 3102RS28001 R S 280 is a modular parallel sect nal valve. Suitable applications are medium sized and big truck loaders, medium sized backhoe loaders and other
More informationSpin-On Filters SSF 24,25
Spin-On Filters SSF,5 Technical Specification Construction Die cast aluminium head Seals NBR (Buna-N ) Port connections Flow rate Working pressure Operating temperature By-pass valve Clogging indicators
More informationFixed Displacement Motor A4FM
Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering
More informationMotion Controls Valve locator
Motion Controls Valve locator unctional Symbol C C Model Cavity low Rating Typical Pressure Page OCV standard L/min (USgpm) bar (psi) CE A9 (5) 7 (4) - CE A66 (8) 7 (4) - CEH A66 (8) 5 (5) - CE9 A6 9 ()
More informationP.C. Flow Regulator Valve Series FR101. General Description
P.C. Flow Regulator Valve Series FR11 Compensated Flow Regulator Valve. NOTE: When used with a fixed displacement pump, pressure to the cartridge must be controlled by a relief valve located between the
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm
Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features
More informationMeter-in pressure compensator, direct operatedtype ZDC
Meter-in pressure compensator, direct operatedtype ZDC Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Meter-in pressure compensator, direct operated Type ZDC Size 10.16.32 up to 35 MPa
More information1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits
/-Way Angle-Seat Valve Type 000 to - NPT; 0 to 30 Advantages / Benefits Spring return closed or open, double-acting Materials: bronze, stainless steel High flow rate Self-adjusting packing glands with
More informationDirectional Control Valves Technical Information Model 1500
Single spool monoblock valve. 26.4 l/min [7 US gal/min] maximum flow. 138 bar [2 psi] maximum pressure with relief. 27 bar [3 psi] maximum pressure without relief. Garden tractors, mowers, utility equipment,
More informationFlow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)
Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for
More information