The above item, as tested, is considered to comply with the above specifications. PAGE 1 OF 6
|
|
- Ernest Barton
- 6 years ago
- Views:
Transcription
1 APPLICANT: Suck UK Limited 31 Regent Studios 8 Andrews Road London E8 4QN DATE: 17 th January 2014 For the attention of Emma SAMPLE DESCRIPTION: Bottlelight REFERENCE / STYLE NO.: SK LIGHTBOTTLE 1 RETAILER: Not specified SAMPLE RECEIVED: 24 th December 2013 PURCHASE ORDER: Not specified TEST REQUEST: ^*EN : A1 : A2 : 2011 ^*EN : A1 : A2 : 2008 (Cat III) CONCLUSION: The above item, as tested, is considered to comply with the above specifications. Tests marked (*) in this Test Report are not included in the UKAS Accreditation Schedule for this Laboratory. Tests marked (^) in this Test Report have been sub-contracted to an agent approved by Intertek. Opinions and interpretations expressed herein are outside the scope of UKAS Accreditation. PAGE 1 OF 6
2 Section 1: Overview This test report refers only to the specific product, configuration and operations modes as detailed in this test report. The manufacturer is advised that he may have a requirement to demonstrate that production samples are also in compliance with the standards noted. Product Name: Bottlelight Manufacturer: Suck UK Limited Description: Rechargeable Light with USB connection Model No: Not stated Part No: Not stated Serial No: Not stated Build State: New Condition of EUT: The EUT was supplied and tested in working condition. Date of testing: 3 rd January 2014 Test Plan: All test were performed in accordance with an agreed test plan. Results Summary: Pass Modifications: The EUT was tested as received, i.e. without any modifications. Uncertainty: Measurement Uncertainties for all tests performed have been calculated and are addressed within this report where appropriate. For conducted immunity and radiated immunity, measurement uncertainty has not been applied to the test level. This is in line with the current Cenelec interpretation of the basic standards. PAGE 2 OF 6
3 Section 2.1 : Radiated Emissions Tested Standard: EN : A1 : A2 : 2011 Frequency Range: 30 MHz to 1000 MHz Operation Mode: The light was tested while charging and also in the on position Below are the top six recorded worst case radiated emissions. Antenna Polarisation Antenna Distance (m) Detector Frequency (MHz) Level (db(µv/m)) Limit (db(µv/m)) Margin (db) Result V 3 Pk >-10 Pass H 3 Pk >-10 Pass Deviations from Standard: None. Additional Comments: No emissions were seen with 10db of the limits when performing he 3m prescans. Therefore maximisation on the OATS was not required. This was the case for testing in the on mode and whilst charging. V = Vertical H = Horizontal Pk = Peak PAGE 3 OF 6
4 Section 2.2 : Electrostatic Discharge Test Standard: EN : A1 : A2 : 2008 Basic Standard: EN :1995 Operation Mode: THE EUT was tested while charging, and also in the on position Observing: Any malfunctions to the EUT or interruption to the illumination Performance Criteria: B Temperature ( C): 17.2 Relative Humidity (%): 44 Pressure (mbar): 998 Contact or Air Discharge? Applied to: +2kV -2kV +4kV -4kV +6kV -6kV +8kV -8kV Result Contact HCP N/A N/A OK OK N/A N/A N/A N/A PASS Contact VCP N/A N/A OK OK N/A N/A N/A N/A PASS Contact Connector (charging mode only) N/A N/A OK OK N/A N/A N/A N/A PASS Air Enclosure N/A N/A N/A N/A N/A N/A OK OK PASS Deviations from Standard: None Additional Comments: None HCP = Horizontal Coupling Plane VCP = Vertical Coupling Plane PAGE 4 OF 6
5 Section 4 : EN Performance Criterion Below is the performance criteria as typically expressed in EMC immunity standards. Performance Criterion A: The apparatus shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Performance Criterion B: The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Performance Criterion C: Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls. PAGE 5 OF 6
6 END OF REPORT This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. PAGE 6 OF 6
TEST REPORT NUMBER: SHAH S1
.cn APPLICANT: JOHNSON INDUSTRIES (SHANGHAI) CO., LTD. DATE: JUL 03, 2012 AI NO.4500, BAOQIAN ROAD, ZHUQIAO TOWN, JIADING DISTRICT, SHANGHAI,CHINA ATTN: SHENG YUAN THIS IS TO SUPERSEDE REPORT NO. SHAH00294894
More informationTest Report #: Date: June 21, 2005
CERTIFICATE #2316.01 Test Report #: 1979-2 Date: June 21, 2005 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Uninterruptable
More informationCADWELL INDUSTRIES, INC. TEST REPORT FOR THE ELECTRONEURODIAGNOSTIC MONITORING SYSTEM, EASY WIRELESS EEG
TESTING CERT #803.01, 803.02, 803.05, 803.06 CADWELL INDUSTRIES, INC. TEST REPORT FOR THE ELECTRONEURODIAGNOSTIC MONITORING SYSTEM, EASY WIRELESS EEG FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS
More information902 MHz 928 MHz Waterproof Dipole 2 dbi Antenna, IP67
902 MHz 928 MHz Waterproof Dipole 2 dbi Antenna, IP67 ORDERING INFORMATION Order Number Description 001-0011 900 MHz Waterproof Dipole Antenna for Reverse Polarity SMA Connector, IP67 080-0013 U.FL to
More informationIEC Test Report for mini-box.com Report No. NF September 29, Test Report
Test Report Report No NF0693-1 Client mini-box.com 4031 Clipper Ct Fremont, CA 94538 Items tested WRAP-BOX-2A-1E Specifications IEC 60529 IP65 Rating Results As detailed within this report Prepared by
More informationFEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*
LPS Medical FEATURES AND BENEFITS Meets UL/EN/IEC60601-1-2, 4Th ed. For EMC* Approved To EN/IEC/UL60601-1, 3rd edition With Isolation Levels Which Satisfy The 2 MOPP Requirements Meets DoE Efficiency Level
More informationModels: BRP391 series; BRP392 series; BRP394 series;
-page 1 of 99-6011997.50 EMC Test report for LED street lighting Models: BRP391 series; BRP392 series; BRP394 series; Shanghai, date of issue: July. 09 th, 2017 Author: Jerremy Cai By order of Philips
More information*HJ * Test Report H (HKGH ) Number:
Applicant: HASBRO S.A. / HASBRO INTERNATIONAL Date: Jun 24, 2016 TRADING B.V. RM 1308 WORLD COMMERCE CTR HARBOUR CITY 11 CANTON RD TSIM SHA TSUI KLN HK ATTN: VICDOR ZHU Submitted samples said to be : Item
More informationSAR COMPLIANCE REPORT
Stanley Black & Decker, Inc. SAR COMPLIANCE REPORT Report Type: FCC SAR assessment report Model: MHL600 REPORT NUMBER: 180501586SHA-002 ISSUE DATE: Aug 30, 2018 DOCUMENT CONTROL NUMBER: TTRFFCCSAR-01_V1
More informationSensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual
Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik
More informationANSI/TIA-568-C : Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009
3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com April 4, 213 Test Report Number: 33592CRT-99 Project Number: 33592 Legrand North America 125 Eugene
More informationTest Report Number: CRT-095 Project Number:
3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com April 17, 213 Test Report Number: 33592CRT-95 Project Number: 33592 Legrand North America 125 Eugene
More informationOperating Manual VSA100A. tina29e1 ( )
Operating Manual Incl. EU Declaration of Conformity Vacuum Switch VSA100A tina29e1 (2017-05) 1 Product Identification In all communications with INFICON, please specify the information on the product nameplate.
More informationPRODUCT MANUAL. Diver Smart Interface Cable AS346
PRODUCT MANUAL Diver Smart Interface Cable AS346 Contact details: Van Essen Instruments B.V. Van Essen Instruments - Canada Delftechpark 20 630 Riverbend Drive, Suite 100 2628 XH Delft Kitchener, ON, The
More informationCONTENT. Report No.: GZ R6. Page 2 of 17
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 HARMONIC OF CURRENT... 7 4.1 USED TEST EQUIPMENT... 7 4.2 BLOCK DIAGRAM
More informationIntertek Testing Services Taiwan Ltd.
1) The testing results relate only to the items tested. Page 2 of 21 2) The test report shall not be reproduced except in full, without written approval of the laboratory. 3) This test report only allows
More informationCardiocom. CD320 Commander Flex FCC :2015 FCC Report # CCOM NVLAP Lab Code:
Cardiocom CD320 Commander Flex FCC 15.207:2015 FCC 15.249.2015 Report # CCOM0021.1 NVLAP Lab Code: 200881-0 This report must not be used to claim product certification, approval, or endorsement by NVLAP,
More informationSMART Oxygen Analyzer. User Manual
SMART Oxygen Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 NITROXBUDDY2 OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 3 6 SETTINGS... 4 6.1 BUTTON... 4 6.2 DISPLAY...
More informationTest Report Number: CRT-026 Project Number:
3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com November 1, 217 Test Report Number: 1246639CRT-26 Project Number: 1246639 Legrand North America Superior
More informationANSI/TIA-568-C-2009: Balanced Twisted-Pair Telecommunications Cabling and Components Standard, dated August 2009
3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com November 1, 217 Test Report Number: 1246639CRT-27 Project Number: 1246639 TEST: Legrand North America
More information863 MHz 870 MHz Dipole 2 dbi Antenna for RP SMA
863 MHz 870 MHz Dipole 2 dbi Antenna for RP SMA ORDERING INFORMATION Order Number Description 001-0028 868 MHz Dipole Antenna for Reverse Polarity SMA Connector 080-0001 U.FL to SMA Bulkhead Cable, 1.13mm
More informationBalance Harness Instructions
Balance Harness Instructions IMPORTANT SAFETY INFORMATION Read before using harness Always read the manual before using the harness. The harness should only be used under the direct supervision and assistance
More informationDATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report
DATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report Number: Approval Date: 20160106 AMSC Number: N9616 Limitation: No DTIC Applicable: Yes GIDEP Applicable: Yes Defense
More informationQUANEX BUILDING PRODUCTS TEST REPORT
QUANEX BUILDING PRODUCTS TEST REPORT SCOPE OF WORK DUAL PANE INSULATING GLASS UNIT PERFORMANCE & GAS EVALUATION REPORT NUMBER H1690.01-119-28 R0 TEST DATE(S) 05/24/17-09/28/17 ISSUE DATE 10/18/17 RECORD
More informationPPS PORTABLE POWER SUPPLY
PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety
More informationWatts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available
-0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationSERVICE LETTER WARRANTY CONDITIONS FOR ROTAX
SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX ENGINE TYPES 912 AND 914 (SERIES) AND 2-STROKE AIRCRAFT ENGINES Repeating symbols: Please, pay attention to the following symbols throughout this document emphasizing
More informationHigh Visibility Clothing
High Visibility Clothing Synopsis This document sets out the minimum specification for high visibility warning clothing. Submitted by Elizabeth Fleming Standards Project Manager Authorised by Brian Alston
More informationA2:1 The Facility Standards are focused on ensuring appropriate standards for the benefit of the Game including:
SECTION A2 MINIMUM STANDARDS FACILITY STANDARDS A2:1 The Facility Standards are focused on ensuring appropriate standards for the benefit of the Game including: Playing facilities to seek to ensure appropriate
More informationIGEM/TD/2 Edition 2 with amendments July 2015 Communication 1779 Assessing the risks from high pressure Natural Gas pipelines
Communication 1779 Assessing the risks from high pressure Natural Gas pipelines Founded 1863 Royal Charter 1929 Patron: Her Majesty the Queen Communication 1779 Assessing the risks from high pressure Natural
More informationCTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration
CTAG:b997e6abfa98cebb6b Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 79 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8
More informationOwner s Manual Humiport 10/20
4201 Lien Rd Madison, WI 53704 Owner s Manual Humiport 10/20 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Humiport line of ThermoHygrometers offers the restoration
More informationATM.ECO - Analog Pressure Transmitter
Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationDigital Inflation Equipment
SINGLE DISPLAY Digital Inflation Equipment 89MXA S P E C I F I C A T I O N S I N S T A L L A T I O N O P E R A T I O N S E R V I C E Please read this manual before carrying out any installation or service
More informationPROGRAMMER OPERATIONS MANUAL
PROGRAMMER OPERATIONS MANUAL Table of Contents Description 4 Installation 4 Operation 5 Safety Precautions 5 Regulatory & Service Information 6 Important Safety and Usage Information 7 Regulatory Notices
More informationUser manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4
User manual PG89 Rev 01 Editi 040515 Pressotherapy model LymphoPress 4 I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it http://www.itechmedicaldivision.com
More informationiphone Application Slurry Pump System Calculator Instructions
iphone Application Slurry Pump System Calculator Instructions Press + to start a New Calculation Enter in Title of the Calculation. Press on saved calculation to open and start calculation. Select U.S.
More informationIncluded with Smoothcut Plasma 100 machine. Plasma 100 Torch Operating manual
3 Included with Smoothcut Plasma 100 machine Plasma 100 Torch Operating manual 2 Important Notice This document has been prepared by BOC Limited ABN 9 000 029 29 ( BOC ), as operating instructions and
More informationCertification Exhibit FCC ID: R7PIWRS4. FCC Rule Part: ACS Report Number: W03.11.A
Certification Exhibit FCC ID: R7PIWRS4 FCC Rule Part: 15.247 ACS Report Number: 09-0412.W03.11.A Manufacturer: Cellnet Technology Inc. Model: Gridstream DCIWR Manual 5015 B.U. Bowman Drive Buford, GA 30518
More informationInfrastructure Requirements for Personal Safety in Respect of Clearances and Access
Infrastructure Requirements for Personal Safety in Respect of Clearances and Access Synopsis This document sets out the design, construction and maintenance requirements for means of access onto, along
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationParametrable / Programmable Pressure Transmitter
Parametrable / Programmable Pressure Transmitter PTM/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available
More informationOIML R 143 RECOMMENDATION. Edition 2009 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL RECOMMENDATION OIML R 143 Edition 2009 (E) Instruments for the continuous measurement of SO 2 in stationary source emissions Instruments pour le mesurage continu de SO 2 dans les émissions
More informationOrganisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids Annex C: Test report format
Organisation Internationale de Métrologie Légale OIML INTERNATIONAL RECOMMENDATION Direct mass flow measuring systems for quantities of liquids Annex C: Test report format Ensembles de mesurage massiques
More information1.1 The Program is administered by the RSL Victoria. Certain services relating to the Program may be provided by Tabcorp.
RSL Rewards Rules These Rules set out the agreement between the person named in the attached membership application form and the RSL Victoria in relation to their membership of the RSL Rewards Loyalty
More informationREMOTE CONTROL OPERATIONS MANUAL
REMOTE CONTROL OPERATIONS MANUAL BASIC MODEL ADVANCED MODEL 1 1 2 2 7 3 3 8 4 6 4 5 5 2 SurfLink Remote allows for easy and discreet adjustments to your hearing instruments. With its long-life battery,
More informationREMOTE CONTROL OPERATIONS MANUAL
REMOTE CONTROL OPERATIONS MANUAL BASIC MODEL 1 2 3 4 5 SurfLink Remote allows for easy and discreet adjustments to your hearing instruments. With its long-life battery, your SurfLink Remote is always on
More informationRoad and rail tankers with level gauging Part 2 Metrological controls and tests. Page 1 of 42 OIML TC8/SC1/WG3/R 80-2 CD1 Draft of July
Page 1 of 42 OIML TC8/SC1/WG3 Circulated to Members of OIML TC8/SC1/WG3 Title Revision R 80-2 Road and rail tankers with level gauging. Metrological controls and tests Discussion by e-mail and at the meeting
More informationGenesis MX SLM-Series
Single Frequency Visible OEM and End-User OPS Laser Systems Applications like Flow Cytometry, Particle Counting, DNA Sequencing and Microscopy are enable by low noise, visible true CW lasers. The Genesis
More informationATM.1ST/Ex - High Precision Transmitter
Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature
More informationCTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration
CTAG:ebdaf8e87fbb5996aefb9 Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 6858 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8
More informationProgrammable Submersible Level Transmitters
Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as
More informationCalibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.
Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up
More informationPR_smart_Part2_Gas. Final PRODUCT REQUIREMENTS FOR PART 2: GAS METERS MARCH 2010 V Copyright 2010 British Gas All Rights Reserved
PR_smart_Part2_Gas Final Turquoise Normal Pale V4.0 2010 03 29 PRODUCT REQUIREMENTS FOR SMART METERING SYSTEMS PART 2: GAS METERS MARCH 2010 CONTENTS INTRODUCTION... 2 1. SCOPE... 2 2. REFERENCES... 2
More informationDual-gas Oxygen and Carbon Monoxide SMART Analyzer User Manual
Dual-gas Oxygen and Carbon Monoxide SMART Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 COOTWO OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 4 6 SETTINGS... 4 6.1 BUTTON...
More informationATM.ECO/IS - Analog Transmitter with Temperature compensation
Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure
More informationINSTRUCTION MANUAL & PARTS BREAKDOWN
24820 Automatic Tire Inflator 3 Modes in One 2347 Circuit Way, Brooksville, Florida, USA 34604 AME INTERNATIONAL Phone: (+1) - 1 352-799-1111 - Toll Phone: (+1) WWW.AMEINTL.NET 877-775-4AME (4263) Fax:
More informationDigital Inflation Equipment 89XDZ 89XDX. Please read this manual before carrying out any installation or service procedures.
Digital Inflation Equipment 89XDX 89XDZ S P E C I F I C A T I O N S I N S T A L L A T I O N O P E R A T I O N S E R V I C E Please read this manual before carrying out any installation or service procedures.
More informationSingtel Mobile Legends Tournament Promotion Terms & Conditions
Singtel Mobile Legends Tournament Promotion Terms & Conditions This Singtel Mobile Legends Tournament ( Promo ) is conducted by SingTel Mobile Singapore Pte. Ltd ( Singapore Telecommunications, Singtel
More informationREMOTE MICROPHONE 2 OPERATIONS MANUAL
REMOTE MICROPHONE 2 OPERATIONS MANUAL Table of Contents Introduction 4 Basic Use 6 Controls Overview 8 Low Battery and Charging 10 Power On/Off Slider 12 Syncing to Hearing Instruments 13 Built-In Microphones
More informationATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502
ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
More informationBCGA GUIDANCE NOTE 17
BCGA GUIDANCE NOTE 17 BCGA POLICY AND GUIDANCE FOR THE SAFE FILLING OF THIRD-PARTY OWNED AND / OR MAINTAINED TANKS Revision 2: 2013 BCGA GUIDANCE NOTE 17 BCGA POLICY AND GUIDANCE FOR THE SAFE FILLING OF
More informationOperating Instruction. E-Pickup 1.5 kw 40% Duty Cycle; Q4/2 Plug Preliminary. Part Number
Part Number 91108-310- 3198705 91108-310-3192260 91108-310-3112884 91108-310-3093037 (Regulators must be ordered separately) 1.5 kw E-Pickup; 40% Duty Cycle; 1150 mm, Q4/2 Plug 1.5 kw E-Pickup; 40% Duty
More informationChoosing and Installing Microbiological Safety Cabinets
Choosing and Installing Microbiological Safety Cabinets Guidance for University Departments and Functions First Edition December 2006 Safety Services Office Issued with the approval of the Biological and
More information2017 IAAF World Championships 4-13 August 2017 London, UK. Selection Policy published February 2017
2017 IAAF World Championships 4-13 August 2017 London, UK Selection Policy published February 2017 Overview British Athletics wish to capitalise on the once in a generation opportunity of hosting the 2017
More informationModel SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA
Calibration Guide Model SM/PL Series Precision Loads Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA Part Number: 10100-00056 Revision: B Published: January 2010 Copyright 2009-2010 Anritsu
More informationThe safety of diver exposure to ultrasonic imaging sonars
CAN UNCLASSIFIED The safety of diver exposure to ultrasonic imaging sonars Ronald Kessel Craig Hamm Maritime Way Scientific Vincent Myers DRDC Atlantic Research Centre UACE2017 4th Underwater Acoustics
More informationSupplementary Certificate of Approval. No S433
12 Lyonpark Road, North Ryde NSW 2113 Australia Supplementary Certificate of Approval No S433 Issued under Regulation 60 of the National Measurement Regulations 1999 This is to certify that an approval
More informationSolenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners
7 634 VGS1... with AGA67 connector VGS2... with AGA67 connector Solenoid gas valve VGS The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners The VGS and
More informationSheet Metal Design Guidelines
Sheet Metal Design Guidelines Issue XVI, Dec 2015 2 Copyright Notice Geometric Limited. All rights reserved. No part of this document (whether in hardcopy or electronic form) may be reproduced, stored
More informationInstallation Instructions JATCO Environmental Protection Tank Model J-7000
Installation Instructions JATCO Environmental Protection Tank Model J-7000 The JATCO Environment Tank must be installed at a level which will allow the waste liquids to be disposed of to gravity flow into
More informationRequirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)
Institut fédéral de métrologie METAS METAS-N001/EN Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T (15 000 G) This document is a translation
More informationGuidance Note. NXT Advisors
Guidance Note NXT Advisors February 2015 CONTENTS 1. Introduction 3 2. Accreditation 4 2.1 Application for accreditation 4 2.2 Accreditation process 4 2.3 Ongoing accreditation 5 2.4 Revoking a NXT Advisor
More informationINSTRUCTION MANUAL. Microphone Type 4966 for Hand held Analyzer Types 2250, 2250 L and Supplement to Instruction Manual BE 1712
INSTRUCTION MANUAL Microphone Type 4966 for Hand held Analyzer Types 2250, 2250 L and 2270 Supplement to Instruction Manual BE 1712 BE 1897 11 English Microphone Type 4966 for Hand-held Analyzer Types
More informationPressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"
F. INTERPRETATION OF THE ESSENTIAL SAFETY REQUIREMENTS ON MANUFACTURING Guideline F-01 Guideline related to: Annex 1 Section 3.1.2 According to section 3.1.2 (permanent joining) of Annex I, the third party
More informationCode Compliance Research Report CCRR-0145
Code Compliance Research Report CCRR-0145 Issue Date: 11-16-2009 Revision Date: 11-29-2018 Renewal Date: 11-18-2019 DIVISION: 05 - Metals Section: 05 50 00 Metal Fabrications Marshall Stamping Company
More informationStatus Date Prepared Reviewed Endorsed Approved
Discipline Engineering Standard NSW Category Signalling Title Introduction to Signalling Maintenance Procedures Reference Number SMP 01 (RIC Standard: SC 00 52 00 01 SI) Document Control Status Date Prepared
More informationArena by Oregon Scientific
Arena by Oregon Scientific 1 Model: SW288 User Manual Arena by Oregon Scientific SWIMWATCH (SW288) USER MANUAL CONTENTS Introduction... 3 Control buttons... 3 LCD... 4 Getting started... 5 Activate watch
More informationWELCOME TO THE REVOLUTION
USER GUIDE WELCOME TO THE REVOLUTION THANK YOU FOR CHOOSING THE GCQUAD We listened to what you wanted - and created the most accurate, versatile and game-enhancing ball and club analysis solution available
More informationWelcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)
Quick Setup Guide Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required) Harvest Model number: 100690-BLK / GRY / WHT / RED Harvest 360 Model
More informationSMART Carbon Monoxide Analyzer. User Manual
SMART Carbon Monoxide Analyzer User Manual TABLE OF CONTENTS 1 WELCOME... 3 2 MONOX OVERVIEW... 3 3 WARNINGS... 3 4 BEFORE FIRST USE... 3 5 QUICK GUIDE... 3 6 SETTINGS... 4 6.1 BUTTON... 4 6.2 DISPLAY...
More informationTOXIC GAS DETECTORS IN THE WORKPLACE UK REGULATIONS AND STANDARDS
SUMMARY TOXIC GAS DETECTORS IN THE WORKPLACE UK REGULATIONS AND STANDARDS In recent articles supplied by the Council of Gas Detection and Environmental Monitoring (CoGDEM) for inclusion in International
More informationAustralian Canoeing. Team Members Bylaw. Adopted by the Board 31 October Bylaw #19. Australian Canoeing PO Box 6805 Silverwater, NSW 2128
Australian Canoeing Team Members Bylaw Adopted by the Board 31 October 2012 Bylaw #19 Australian Canoeing PO Box 6805 Silverwater, NSW 2128 Tel: (02) 8116 9727 Fax: (02) 8732 1610 Web: canoe.org.au 1.
More informationGAS CONNECTORS GAS BALL VALVES/END FITTINGS
GAS CONNECTORS GAS BALL VALVES/END FITTINGS Quality Guarantee DuraTrac believes that a gas connector is more than a gas connector. We believe that a gas connector is a commitment to safety. The DuraTrac
More informationCOOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN
Surge Arresters MN235023EN Effective November 2016 Supersedes October 2006 (S235-95-1) COOPER POWER SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions HIGH
More informationD10 Inflator Quick Start Manual
PART NUMBER SERIAL NUMBER D10 Inflator Quick Start Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationV O L L E Y B A L L S E T
S E T Assembly & Installation Instructions 3 0 5 0 S. A L V E R N O N W A Y T U C S O N, A Z 8 5 7 1 3 5 2 0. 7 9 0. 7 0 4 0 8 0 0. 7 3 7. 5 3 8 6 F A X 5 2 0. 7 9 0. 7 1 2 7 i n t e r - f a b. c o m TABLE
More informationTraining Workshop «DO160/ED14» - Jessica France
Training Workshop «DO160/ED14» - Jessica France DO160/ED14 Issue F to G Edouard ZUNDEL Systems Qualification Engineer for Mechanical and Climatic aspects 1 Overview - Temperature &Altitude Procedure clarification
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationATM.1ST. Pressure transmitters CUSTOMER BENEFITS
Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections
More informationThe Faraday Test Centre Rochester
Rochester REAL CAPABILITY. REAL ADVANTAGE. BAE Systems is an international company engaged in the development, delivery and support of advanced defence and aerospace systems in the air, on land, at sea
More informationMegabucks & Megabucks Gold
Rules of the Game for Clubs Long Form Megabucks& Change History Version Issue Date Description Author 1.0 1 August 2014 Rules of the Game Long Form Jason Williams - 30 September 2016 Updated to include
More informationGAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK
SPECIFICATION FOR GAS TRANSPORTER S REQUIREMENTS FOR GAS MEASUREMENT SYSTEMS CONNECTED TO THE NATIONAL GRID GAS NETWORK J510 ( Rev 04/06 ) OCTOBER 2005 . CONTENTS Page FOREWORD BRIEF HISTORY iii iii INTRODUCTION
More informationPasture Meter Auto Lift Kit 5003 (Leaflet Pt.No Issue 4, October 2015)
Pasture Meter Auto Lift Kit 5003 (Leaflet Pt.No.2400-1210 Issue 4, October 2015) DESCRIPTION The C-Dax Auto lift kit is an optional extra for the C-Dax Pasture Meter and raises/lowers the pasture meter
More informationContact person Date Reference Page Michael Lindblad F025843A 1 (1) Sustainable Built Environment
issued by an Accredited Testing Laboratory Contact person Michael Lindblad 2016-02-03 5F025843A 1 (1) Sustainable Built Environment +46 10 516 58 58 Michael.Lindblad@sp.se Accred. No. 1002 Testing ISO/IEC
More informationMATERIAL SAFETY DATA SHEET
OMS Date revised: 07-16-2004 SECTION 1 MATERIAL AND MANUFACTURER IDENTIFICATION Product Identifier: Product Use: OMS Upholstery restoration. MANUFACTURER CTI (Chemical Technologies International Inc.)
More information«DO160/ED14» - Jessica France
Training Workshop «DO160/ED14» - Jessica France DO160/ED14 Specificities of Mechanical and Climatic aspects Edouard ZUNDEL Systems Qualification Engineer for Mechanical and Climatic aspects 1 The reference
More informationEUROPEAN QUALIFIERS HOME MATCH PACKAGE TICKET TERMS & CONDITIONS
EUROPEAN QUALIFIERS HOME MATCH PACKAGE TICKET TERMS & CONDITIONS These terms and conditions (the Terms and Conditions ), together with the Membership Terms and Conditions govern the Member s purchase of
More information