Chapter 14 Water Shuttle Operations

Size: px
Start display at page:

Download "Chapter 14 Water Shuttle Operations"

Transcription

1 1. Which of the following statements about water shuttle operations is TRUE? A. Water shuttle operations may create a dramatic hose failure B. Water shuttle operations are safer than relay pumping operations C. Water shuttle operations are less labor intensive than relay pumping operations D. Water shuttle operations provide a more reliable continuous water supply than relay pumping operations 2. Which types of apparatus are positioned at the water supply source and are used to fill empty water tenders? A. Fill site pumpers B. Dump site pumpers C. Water tender/tankers D. Water shuttle tankers 3. Which types of apparatus are located at or near the fire scene and are used to draft water from a portable water tanks? A. Fill site pumpers B. Dump site pumpers C. Water tender/tankers D. Water shuttle tankers 4. Which of the following are consider the backbone of any water shuttle operation? A. Fill site pumpers B. Dump site pumpers C. Water tender/tankers D. Water shuttle tankers 5. Water tenders must have a tank-to-pump line capable of supplying the pump with 500 gpm until at least of the tank is empty A. 50% B. 60% C. 70% D. 80% 6. Water tenders must be equipped with at least one external connection to allow a filling at a minimum rate of: A gpm B gpm C gpm D gpm

2 7. Water tenders must have a discharge capable of emptying of the tank volume at an average rate of 1000 gpm. A. 75% B. 80% C. 85% D. 90% 8. Although NFPA 1901 only requires one large tank discharge be installed on a water tender, it is highly recommended that each tender be equipped with at least: A. Two B. Three C. Four D. Five 9. Which type of tank discharges employ the use of a small diameter in line discharge that is inserted into the piping of the large tank discharge? A. Dump tanks B. Dump valves C. Gravity dumps D. Jet assisted dumps 10. Which of the following statements about jet assisted dumps is TRUE? A. They are resistant to piping freezing B. They decrease the cost of purchasing an apparatus C. Water cannot be discharge unless the pump is operated D. There is a danger of water being discharged over the portable tank and hitting anyone or anything on the other side 11. Which of the following is NOT a decision that must be made at the beginning of an incident? A. Location of the fill site B. Location of the dump site C. Route of travel between dump and fill sites D. Route of travel between station an incident 12. The Des fill and dump sites are those in which the water tenders: A. Back in, Phillip or bill, then proceed straight out B. Maneuvered quite a bid to insure the perfect location C. Drive straight in from one direction, fill or dump, then precede straight out D. Drive in from one direction, fill and dump, then back out using the entrance

3 13. The route of travel selected for a shuttle operation should reflect: A. Only safety B. The fastest route C. Both safety and operational efficiency D. The route with the least amount of stops 14. On fire incidents, the may choose to establish a water supply branch or group that includes the water shuttle operation A. Driver/operator B. Incident commander C. Water supply group supervisor D. Water supply branch director 15. When the water supply Peru is established, the person in charge is known as the: A. Driver/operator B. Incident commander C. Water supply group supervisor D. Water supply branch director 16. The purpose of the fill site operation is to: A. Unload full tenders as expediently as possible B. Reload and the tender's as expediently as possible C. Unload full tenders as slowly as safely as possible D. Reload and the tender's as slowly and safely as possible 17. Who must determine the best position for drafting or hydrant connection? A. The driver/operator B. The incident commander C. The water supply branch supervisor D. The water supply proved supervisor 18. Ideally, when positioning the fill site pumper, the pump panel should be located so that the driver/operator can view: A. Only the pump panel B. Only the fill operations C. Only the source operations D. Both the fill and source operations

4 19. Regardless of whether a hydrant or static source is used, a should be continuously flowed from the fill site pumper to prevent a loss of prime A. 2 1/2 inch outlet B. Large-diameter intake hose C. Medium diameter intake hose D. Booster line or some other type of small discharge line 20. Although hose is used to fill tenders very, most common and most efficient are: A. One of 3 inch direct tank fill connection and one LDH direct tank fill connection on the side of the vehicle B. Two 2 1/2 inch direct tank fill connections or one LDH direct tank fill connection on the rear of the vehicle C. Two 2 1/2 inch direct tank fill connections and two LDH direct tank fill connections on the rear of the vehicle D. Three 2 1/2 inch direct tank fill connections or one LDH direct tank fill connection on the side of the vehicle 21. The ideal fill position is one that: A. Allows the driver/operator to back in, fill the tender, then proceed straight out B. Causes the driver/operator two maneuvered quite a bid to insure the perfect location C. Allows the driver/operator to enter and exit the fill site without turning around or backing up D. Allows the driver/operator to drive in from one direction, fill the tender, then back out using the entrance 22. If available, inch hose should be used to fill tenders as it allows for quicker filling of the tank A. 1½ inch B. 2 1/2 inch C. 3 inch D. 4 inch 23. What is the problem with using portable fill pipes may of PVC to top fill water tenders? A. PVC becomes brittle and extremely cold weather B. PVC becomes brittle and extremely warm weather C. PVC creates an inadequate flow rate through the fill pipe D. PVC made needs some jockeying to get directly above the tank opening

5 24. At the fill site, it is recommended that the fill site pumper remain with a tender fill lines charge at all times A. In gear B. In park C. Moving D. Shut off 25. Who should monitor the ground conditions around the fill site? A. The driver/operator B. The incident commander C. The dump site officer D. The make and break personnel or fill site officer 26. When should the fill site be shut down? A. When the driver/operators report that the fire seems to be under control B. When the decision has been made that the operation is no longer necessary C. After a set amount of time(such as 2 hours), to be determined by the incident commander D. When it is station has been made that the operation is no longer necessary and all tenders for participating in the shuttle have been emptied 27. In which dump site method does a water tender pump the water from its tank directly into the pump intake of the attack pumper? A. Nursed tank operations B. Direct pumping operations C. Interact pumping operations D. Portable water tank operations 28. Which dump site method uses one or more portable water tanks as the dump site water supply source? A. Nurse tender operations B. Direct pumping operations C. Interact pumping operations D. Portable water tank operations 29. In which dump site method is the tender's usually so large that the fire is controlled before there is a need to refill its tank? A. Nurse tender operations B. Direct pumping operations C. Interact pumping operations D. Portable water tank operations

6 30. Which of the following is not a water tender discharge method? A. Top filling B. Using a dump valve C. Using a pump on the tender D. Pumping and dumping simultaneously 31. Single portable tank operations work on fires that require less than: A. 300 gpm B. 400 gpm C. 500 gpm D. 600 gpm 32. Before shutting down a dump site operation, it is generally a good idea to make sure that the attack apparatus and dump site pumper have: A. Topped off their fuel tanks B. Flushed their hoses and pumps C. Emptied their board water tanks D. Topped off their on board water tanks 33. Which of the following is the equation for determining the travel time of a shuttle operation? A (1.7)(Distance in miles) [ (1.06)(Distance in km)] B (1.48)( Distance in feet) [ (2.56)( Distance in m)] C (6.5)(Average travel speed) [ (8.2)( Average travel speed)] D (1.07)(Maximum travel speed) [ (1.60)( Maximum travel speed)] 34. Which of the following is the equation for determining the handling time of a shuttle operation? A. Fill site time + dump site time B. Fill site time - dump site time C. Fill site time x dump site time D. Fill site time dump site time 35. Which of the following is the equation for determining tender flow rate? A. (Tender water size - 10%) (Travel time x Handling time) B. (Tender water size - 10%) (Travel time + Handling time) C. (Tender water size - 20%) (Travel time - Handling time) D. (Tender water size - 50%) (Travel time + Handling time)

7 Chapter 14 Answers 1. C (417) 19. D (432) 2. A (418) 20. B (432) 3. B (418) 21. C (432) 4. C (419) 22. C (433) 5. D (421) 23. A ( ) 6. A (421) 24. A (434) 7. D (421) 25. D (435) 8. B (423) 26. B (435) 9. D (424) 27. B (436) 10. D (424) 28. D (437) 11. D (425) 29. A (436) 12. C (425) 30. A (437) 13. C (428) 31. A (439) 14. B (429) 32. D (444) 15. C (429) 33. A (445) 16. B (430) 34. A (445) 17. A (431) 35. B (446) 18. D (431)

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA TOPIC: RELAY PUMPING OPERATIONS LEVEL OF INSTRUCTION: TIME REQUIRED: ONE HOUR INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO VISUAL SUPPORT REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST

More information

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA

PROPERTY INSURANCE ASSOCIATION OF LOUISIANA PROPERTY INSURANCE ASSOCIATION OF LOUISIANA WATER HAULING GUIDELINES NOTE: Effective immediately, Fire Departments in Louisiana who receive credit for water hauling will receive their credit through a

More information

Essentials of Fire Fighting

Essentials of Fire Fighting Essentials of Fire Fighting 6 th Edition Certified Volunteer Firefighter Chapter 14 Water Supply Learning Objectives Explain the ways water supply system components are used by firefighters. Describe types

More information

Apparatus Operator Refresher Training Program

Apparatus Operator Refresher Training Program Division of Training In-Service Training Program Apparatus Operator Refresher Training Program 1 Single Engine / Single Line Operation Refresher Evolution #1 Objective: Charging single handlines at correct

More information

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011

Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011 W ATER S UPPLY O PERATIONS R URAL (1.1) Developed by Engineer Ben Wynkoop, Lieutenant Randy Stuart, and Firefighter Alex Klinger September 2011 NFPA 1142 Standard on Water Supplies for Suburban and Rural

More information

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011

Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011 W A T E R S U P P L Y O P E R A T I O N S R U R A L ( 2. 1 ) Developed by Lt. Randy Stuart Eng. Ben Wynkoop, and FF. Alex Klinger in Sept 2011 Revised by Lt. Greg Van Heel, Eng. Chris Wining, and FF. Uriel

More information

TurboDraft Fire Eductor

TurboDraft Fire Eductor TurboDraft Fire Eductor Operating Manual Introduction The TurboDraft is designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner.

More information

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus.

The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus. Section I: Apparatus Knowledge The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus. 1. The Apparatus Driver/Operator demonstrates

More information

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question. Chapter 15 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Distinguish among preperformance tests for pumping apparatus. 1. Which standard is commonly

More information

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker:

Apparatus Driver/Operator Evaluation Form Rosenbauer Tanker: Section I: Apparatus Knowledge The Evaluator shall ask the Apparatus Driver/Operator questions regarding the mechanical systems and size of the apparatus. 1. The Apparatus Driver/Operator demonstrates

More information

Essentials of Fire Fighting 6 th Edition Firefighter I

Essentials of Fire Fighting 6 th Edition Firefighter I 1 Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 14 Water Supply Learning Objective 1 2 Explain the ways water supply system components are used by firefighters. 14 2 There are two types

More information

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010

Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010 W ATER S UPPLY O PERATIONS M UNICIPAL/SUBURBAN (1.1) Developed by Lieutenant Randy Stuart, Engineer Matt Hintzman and Firefighter Chris Sandoli November 2010 NFPA 1142 Standard on Water Supplies for Suburban

More information

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition) Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs ( Edition) JPR # Task Initial Certification JPR Requirement: 15 Mandatory Renewal JPR Requirement: 100% of All JPRs (including

More information

Tanker Fill Tests. Evaluating Direct Fill Lines DeKalb County, Alabama. November 16, Tests DeKalb County, AL

Tanker Fill Tests. Evaluating Direct Fill Lines DeKalb County, Alabama. November 16, Tests DeKalb County, AL www.gotbigwater.com Tanker Fill Tests Evaluating Direct Fill Lines DeKalb County, Alabama November 16, 2008 Overview On November 15 th and 16 th, 2008, the DeKalb County (AL) Association of Fire Departments

More information

Apparatus Operator/Pumper

Apparatus Operator/Pumper Skill Number: AOP-1 Operate Fixed Systems Objective: 4.3.7 (A) (B) 1. The candidate shall be provided with the equipment to complete this objective including apparatus. 2. The candidate uses safety precautions.

More information

TurboDraft. Fire Eductor Operating Instructions.

TurboDraft. Fire Eductor Operating Instructions. TurboDraft Fire Eductor Operating Instructions 1234djfkjldfjlkdjfklsdjlkjfdslkjfsd Table of Contents Description Page Introduction........ 1 Safety Guidelines... 2 Care and Maintenance... 3 TurboDraft

More information

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system.

Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system. Water Supply - 1 UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: 1. Identify the parts of a water distribution system. 2. Identify the causes of increased resistance

More information

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1 Skill Sheet: 1 Standard 4.2.1, 4.2.2 Task: Perform and document routine test, inspection and servicing functions on specified systems and components. Performance Outcome: Given a fire department pumping

More information

Atlantic County Tender Task Force B Bravo Division When Atlantic County Tender Task Force B is required the following procedure should be followed:

Atlantic County Tender Task Force B Bravo Division When Atlantic County Tender Task Force B is required the following procedure should be followed: Atlantic County Tender Task Force B Bravo Division When Atlantic County Tender Task Force B is required the following procedure should be followed: Notify District 25 Atlantic County Sheriff s Department

More information

Irrigation System Winterization and Pressurization Procedures

Irrigation System Winterization and Pressurization Procedures Irrigation System Winterization and Pressurization Procedures Introduction Any time that an irrigation system is filled and pressurized, or when the system is drained and water flushed from the system,

More information

Cozumel Turbodraft. Operational Considerations

Cozumel Turbodraft. Operational Considerations Cozumel Turbodraft Operational Considerations Safety Guidelines Safety Guidelines 1. Carefully read and follow all operating instructions before putting the TurboDraft unit into service. 2. Be sure all

More information

Driver Operator Pumps: Basic Pump Operations

Driver Operator Pumps: Basic Pump Operations Driver Operator Pumps: Basic Pump Operations 5 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Basic Pump Operations Skills Book NFPA

More information

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Water Supplies 2 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Water Supplies Skills Book JPR NFPA 1002 Task:

More information

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition) Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs () JPR # Task Initial Certification JPR Requirement: 15 Mandatory Renewal JPR Requirement: 100% of All JPRs (including all subsections)

More information

KILGORE FIRE DEPARTMENT

KILGORE FIRE DEPARTMENT Page 1 of 13 KILGORE FIRE DEPARTMENT Operations/ SOP Directive Issue Date: 01/01/2013 237 Effective: 01/01/2013 COMPANY PERFORMANCE STANDARDS 237.1 Purpose The purpose of this procedure is to define and

More information

Varying pump capacity affects the required hoseline diameter

Varying pump capacity affects the required hoseline diameter Slide 1 Rural Fire Command by Larry Davis Issue #34 October 2005 H 2 O On The Go Varying pump capacity affects the required hoseline diameter 1 Slide 2 Training America s Rural Fire & Emergency Responders

More information

Galva Fire Department SOP

Galva Fire Department SOP Galva Fire Department SOP GENERAL REGULATIONS All firefighters must know and understand the SOG s set forth by the GFD. GFD personnel will be alerted of a call by pager, fire phone or by the fire siren

More information

Evaluating 2-1/2 Direct Fill Lines Colton, New York

Evaluating 2-1/2 Direct Fill Lines Colton, New York www.gotbigwater.com Tanker Fill Tests Evaluating 2-1/2 Direct Fill Lines Colton, New York August 24, 2008 Overview On August 23 rd and 24 th, 2008, the Colton (NY) Fire District hosted a Rural Water Supply

More information

Water Supply for Suburban and Rural Firefighting

Water Supply for Suburban and Rural Firefighting FIRE AND RESCUE DEPARTMENTS OF NORTHERN VIRGINIA FIREFIGHTING AND EMERGENCY OPERATIONS MANUAL Water Supply for Suburban and Rural Firefighting Second Edition Issued: 2003 Revised: November 2017 ACKNOWLEDGEMENTS

More information

Driver Releasal Manual

Driver Releasal Manual Driver Releasal Manual In order to participate in the DPO program, the candidate must: o Possess a valid Virginia Driver s License o Be 18 years of age o Be covered under the County insurance policy o

More information

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 SUPPLEMENT 101 101. HIGH PRESSURE FIRE HYDRANT SYSTEM The High Pressure

More information

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION

MFD Monroe Fire Department. Standard Operating Guidelines. Drivers Clearance & Training Program Guidance ADMINISTRATION Monroe Fire Department Standard Operating Guidelines Drivers Clearance & Training Program Guidance ADMINISTRATION Goal: to develop and maintain a force of driver-operators and ensure they are proficient

More information

Standard Operating Procedures S.O.P. Sample Template Drafted by: Oklahoma State Firefighters Association Educational Advisory Committee

Standard Operating Procedures S.O.P. Sample Template Drafted by: Oklahoma State Firefighters Association Educational Advisory Committee Standard Operating Procedures S.O.P. Sample Template Drafted by: Oklahoma State Firefighters Association Educational Advisory Committee ** Remember Safety First ** INTRODUCTION Remember, the following

More information

Waterous Relief Valve

Waterous Relief Valve Operating Instructions 1. Reduce pump discharge pressure with engine throttle. Make sure four way (On/Off) valve is OFF. 2. Open at least one discharge valve. Accelerate engine until pressure gage indicates

More information

CONSIDERATIONS FOR THE USE OF SEA WATER IN FIREFIGHTING. Prepared and Presented by Lenny Naidoo (Chief Fire Officer), Engen Petroleum Company

CONSIDERATIONS FOR THE USE OF SEA WATER IN FIREFIGHTING. Prepared and Presented by Lenny Naidoo (Chief Fire Officer), Engen Petroleum Company CONSIDERATIONS FOR THE USE OF SEA WATER IN FIREFIGHTING Prepared and Presented by Lenny Naidoo (Chief Fire Officer), Engen Petroleum Company Content Introduction Risk Assessment Legal Obligations Planning

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised DRIVER OPERATOR Page 1 of 14 HYDRAULICS Hydraulics applied in the dynamic fire ground environment is an art that comes with study and experience. The following describes the factors that must be mastered

More information

Flow Material Length. Weight GPM LPM. Style 3095

Flow Material Length. Weight GPM LPM. Style 3095 Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi

More information

Wilton Fire Protection District. TRAINING DIVISION New apparatus

Wilton Fire Protection District. TRAINING DIVISION New apparatus Wilton Fire Protection District TRAINING DIVISION New apparatus OPERATIONAL SIGN-OFFS 3/05 OPERATIONAL SIGN-OFF PACKET To: ALL PERSONNEL The purpose of this Operational Sign-off Packet is to provide all-line

More information

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087 SOG Name: One and Two Family Dwellings SOG Number: 403.18 Effective Date: February 2, 2015 Approved: Joey Cooper, Director Reviewed: Scope This procedure will provide an organized method in which to carry

More information

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2017 Edition. Alabama Fire College August, 2018 revised

More information

2017 Volunteer Week - Course Descriptions

2017 Volunteer Week - Course Descriptions 2017 Volunteer Week - Course Descriptions 40 Hour Course - S130/S190/L180 Introduction to Wildland Firefighting S190 This course provides instruction in the primary factors affecting the start and spread

More information

Discharge Relief Valve Operation & Maint.

Discharge Relief Valve Operation & Maint. Relief Valve Operation & Maint. CZ Series Centrifugal Fire Relief svalve Operation and Maintenance Instructions 1410 Operation and Maintenance Form No. F-1031 Section 2302.6 2111 Issue Date 04/90 11/95

More information

UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to:

UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: BASIC FIRE FIGHTER ORIENTATION AND COMMUNICATIONS Orientation and Communications 1 UNIT OBJECTIVES Upon completion of this unit of study, the student should be able to: 1. Identify the organization of

More information

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE October 21, 2010 Pumping Systems for Landscaping Pumps, Controls and Accessories Mark Snyder, PE Pump Station Design Purpose of Pump Stations Pump stations are designed to boost water pressure from a lower

More information

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU FIRE FIGHTER II SKILL STATION MENU STATION TASK(S) A FIREGROUND OPERATIONS/FIRE COMMUNICATIONS MANDATORY B SPRINKLER DRAIN/PRESSURES RANDOM C PITOT GAUGE USE RANDOM D INSPECTION/MAINTENANCE: GENERATOR,

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET Fire Fighter II Skill Stations: NFPA 1001 2013 Edition Station A Fire Ground Communications & Operations / Interior Attack Coordination MANDATORY STATION Station B Sprinkler Drain/Pressures RANDOM STATION

More information

Chapter Overview. NFPA Standards NFPA 1001 Standard. Fire Fighter I

Chapter Overview. NFPA Standards NFPA 1001 Standard. Fire Fighter I Chapter Overview Consider a fire in a one-story, wood frame residential structure with one room fully engulfed in flames. Two engines arrive followed closely by a ladder truck. Each apparatus carries an

More information

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines. Dry Hydrants What is a Dry Hydrant? A dry hydrant is a non-pressurized pipe system permanently installed in existing lakes, ponds and streams that provides a suction supply of water to a fire department

More information

Piped Air SCBA Refilling System Standard

Piped Air SCBA Refilling System Standard WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Piped Air SCBA Refilling System Standard SCOPE: This specification

More information

Reverse Osmosis System Installation Guide and Operation Manual.

Reverse Osmosis System Installation Guide and Operation Manual. Reverse Osmosis System Installation Guide and Operation Manual. Table of Contents 1 Introduction...2 2 Installation...3 2.1 Feed water connection...3 2.2 Permeate and concentrate plumbing...3 2.3 Electrical

More information

FSRS Relative Point Value Guide

FSRS Relative Point Value Guide FSRS Relative Point Value Guide Note: This document has been produced by PIAL as a "guide" to show each 's impact to your total score. Certain ideal scenarios were assumed to determine the score in the

More information

Pump Stages. By Tom Murray

Pump Stages. By Tom Murray Pump Stages By Tom Murray As is often the case, we in the fire service tend to make things more difficult than they need to be. I believe this is the situation when discussing the pros and cons of single,

More information

6900 Maintenance Instruction System Flush

6900 Maintenance Instruction System Flush Equipment Required FA74005 Damper Drain Tube FA16005 Cover Removal Tool FA900005 Beaker 0.25 Litre FA900003 Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves Latex

More information

Des Plaines Fire Dept. Engineer Program

Des Plaines Fire Dept. Engineer Program Des Plaines Fire Dept. Engineer Program Lieutenants Palenik, Gross, Owen, Butenschoen, Engineer Felde New Developments 1. Laminated fluid specs on the rigs 2. Maintenance repair request updates 3. Locations

More information

6800 Maintenance Instruction System Flush Procedure

6800 Maintenance Instruction System Flush Procedure Equipment Required FA74005 FA65318 FA900005 FA900003 Damper Drain Tube 6800 Cover Removal Tool Beaker 0.25 Litre Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves

More information

Chapter 9 System Design Procedures

Chapter 9 System Design Procedures Chapter 9 CHAPTER 9 SYSTEM DESIGN PROCEDURES TABLE OF CONTENTS PART 9.1 GENERAL 9-1 PART 9.2 EXAMPLE 1, LOW PRESSURE GRAVITY SYSTEM 9-1 PART 9.3 EXAMPLE 2, PUMPED AUTOMATIC PRESSURE PIPELINE 9-4 9.3.1

More information

Iowa s s Minimum Training Standard. How to Be Prepared?

Iowa s s Minimum Training Standard. How to Be Prepared? Iowa s s Minimum Training Standard How to Be Prepared? Volunteer Firefighters Volunteer Fact Sheet Volunteers comprise 73% of firefighters in the Unites States. Communities served by Volunteer Firefighters

More information

Bitumen Delivery Driver Inductions Eurobitume UK

Bitumen Delivery Driver Inductions Eurobitume UK Bitumen Delivery Driver Inductions Eurobitume UK The information in this module is given in good faith and belief in its accuracy at the time of publication, but does not imply any legal liability or responsibility

More information

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/Operator Professional Qualifications, 2014 Edition. Alabama Fire College February 2016 revised

More information

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.

More information

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05 Standard Operating Guidelines Page: 1 of 8 15.05 Scope: This procedure will provide an organized method in which to carry out the fire ground functions in a timely and safe manner. Discussed will be the

More information

At this time of year,

At this time of year, At this time of year, we hope bobtails are scurrying about to meet demand. As you do so, there are a few things your drivers should be doing to make sure that they and your customers are kept safe. A safe

More information

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE www.agprousa.com Over 20 types to satisfy all your flushing needs. Agpro Flush Valves are fully operational units designed for one purpose, flushing

More information

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019

Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019 Practical Skill Sheets Fire Apparatus Driver/Operator Pumper January 2019 Effective 1/1/2019 Fire Apparatus Driver/Operator-Pumper Practical Skill Sheets 1 Table of Contents Acknowledgements... 3 Driver/Operator

More information

Report of the Committee on Public Water Supplies for Private Fire Protection

Report of the Committee on Public Water Supplies for Private Fire Protection PWS-1 COMMITTEE ON PUBLIC WATER SUPPLIES ~ FLOW TESTING 291-5 ~ O Report of the Committee on Public Water Supplies for Private Fire Protection Recommendations for Fire Flow Testing and Marking of Hydrants

More information

FIREGROUND HYDRAULICS

FIREGROUND HYDRAULICS INTRODUCTION This section is designed to give pump operators a quick and fairly easy process for determining fire ground hydraulics. Supplying water is a critical part of the control, and the efficient

More information

S P E C I A L O P E R A T I O N S : S W I F T W A T E R B O A T O P E R A T I O N S ( 1. 1 ) T A S K S K I L L D E S C R I P T I O N A N D D E T A I L

S P E C I A L O P E R A T I O N S : S W I F T W A T E R B O A T O P E R A T I O N S ( 1. 1 ) T A S K S K I L L D E S C R I P T I O N A N D D E T A I L S P E C I A L O P E R A T I O N S : S W I F T W A T E R B O A T O P E R A T I O N S ( 1. 1 ) Developed by: Jason Tanner October 2015 T A S K S K I L L D E S C R I P T I O N A N D D E T A I L Swiftwater

More information

SCENARIO 18 Leak on Intermodal Pressure Tank Container

SCENARIO 18 Leak on Intermodal Pressure Tank Container INCIDENT OVERVIEW Your fire department responds to a marine terminal for a report of a gas leak involving an intermodal tank in a container yard. Upon arrival at the marine terminal, the Port Authority

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

San Ramon Valley Fire Protection District

San Ramon Valley Fire Protection District San Ramon Valley Fire Protection District March, 2009 Company Performance Standards i Introduction This manual establishes a series of standard incident-based company evolutions for District use. Collectively,

More information

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised HOSE 12-01-16 PAGE 1 OF 24 To effectively attack and extinguish a fire, hose lines must be removed from the apparatus and advanced to the location of the fire. The techniques used to advance hose lines

More information

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal F I R E A P P A R A T U S DRIVER/OPERATOR 1B Approved and Adopted by the Office of State Fire Marshal Recommended for adoption by the Statewide Training and Education Advisory Committee and the State Board

More information

Geotech 1.66 Auto-Reclaimer Installation and Operation

Geotech 1.66 Auto-Reclaimer Installation and Operation Geotech 1.66 Auto-Reclaimer Installation and Operation Rev 10/19/12 Part # 16600165 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM

More information

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Geotech 1.66 Auto-Reclaimer Installation and Operation Rev 9 8/31/06 Part # 16600165 TABLE OF CONTENTS CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 SYSTEM COMPONENTS... 4 CHAPTER 2: SYSTEM

More information

OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4

OVERVIEW pg 3. Major Points to Consider pg 3 Minor Points to Consider pg 3. INSTRUCTIONS pg 4 TABLE OF CONTENTS OVERVIEW pg 3 Major Points to Consider pg 3 Minor Points to Consider pg 3 INSTRUCTIONS pg 4 How Does Nordic Freeze Work pg 4 How Long Will the Ice Plug Take to Form pg 4 How Do I Know

More information

Chapter 1 FF I Orientation and Fire Service History

Chapter 1 FF I Orientation and Fire Service History Chapter 1 FF I Orientation and Fire Service History After completing this lesson, the student shall be able to describe how the history and culture of the fire service influence its basic mission, the

More information

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS 5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS 23 24 5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS INSPECTING, FILLING AND LABELING SMALL CYLINDERS Pre-fill Visual Check Safely inspecting

More information

Series 58 SAFETY VALVES 312

Series 58 SAFETY VALVES 312 312 Series ASME AIR BRASS SAFETY SOLUTION FEATURES AND BENEFITS High quality, corrosion-resistant safety valves Optimum high flow discharge rates CRN OG-3724 S Manufactured under the regulations of the

More information

Mobile Breathing Air Systems

Mobile Breathing Air Systems FAMA BUYER S GUIDE TC053 Prepared by the FAMA Body Subcommittee This guide does not endorse any manufacturer or product Page 1 of 14 Contents Introduction... 3 Overview... 4 Mobile Breathing Air System

More information

WORKHOLDING APPLICATION BOOKLET

WORKHOLDING APPLICATION BOOKLET WORKHOLDING APPLICATION BOOKLET Applications and advantages of using minibooster hydraulic pressure intensifiers MINIMUM SIZE MAXIMUM POWER B-GB Workholding 2018.04 1 of 20 2 of 20 B-GB Workholding 2018.04

More information

To establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires.

To establish a guideline for the safe and effective deployment of apparatus, personnel, and resources at the scene of structural fires. Buxton Fire-Rescue Standard Operating Guideline Subject: Structural Fire (3) Section: Operations at Structure Fires (2) Page 1 of 7 Purpose: To establish a guideline for the safe and effective deployment

More information

ENGINE COMPANY OPERATIONS CHAPTER 12 February 15, 2006 WATER LOSS PROCEDURES

ENGINE COMPANY OPERATIONS CHAPTER 12 February 15, 2006 WATER LOSS PROCEDURES CHAPTER 12 February 15, 2006 WATER LOSS PROCEDURES 1. WATER LOSS PROCEDURES 1.1 The loss of water on the fire ground is a very serious situation, and something all members should strive to prevent. The

More information

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 5 TOPIC: SUPPLY LINES AND SALVAGE LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED

More information

second test was conducted using at 3/4inch nozzle to determine a practical maximum pressure for the pump.

second test was conducted using at 3/4inch nozzle to determine a practical maximum pressure for the pump. I am writing this memo to you from the perspective of a fire apparatus operator and tester. Though I offer this collection of my observations and opinions, I do so voluntarily but with the full integrity

More information

ENGINE 260 REVISED

ENGINE 260 REVISED ENGINE 260 REVISED - 2018-1- TABLE OF CONTENTS General Rules... 3-4 Event Rules Ladder Climb... 5 Tug-O-War... 7 Lakeside Draft Motorized... 7 Hand Pumpers... 8 Midnight Alarm... 9 Water Barrel... 10 Arena

More information

NFPA Standard on. Training for Initial Emergency Scene Operations Edition

NFPA Standard on. Training for Initial Emergency Scene Operations Edition NFPA 1410 Standard on Training for Initial Emergency Scene Operations 2005 Edition Copyright 2005, National Fire Protection Association, All Rights Reserved This edition of NFPA 1410, Standard on Training

More information

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program Welcome & Introductions Identify emergency exits to all participants. Identify location of restroom facilities. Cover any other related

More information

Ocean County Fire Academy. Fall 2018 Course Listings

Ocean County Fire Academy. Fall 2018 Course Listings Ocean County Fire Academy Fall 2018 Course Listings Fall 2018 Class Schedule September Stand Pipe Operations September 19 Stand pipes are being found more often in many types of buildings and special locations.

More information

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Chapter 16 Test. Directions: Write the correct letter on the blank before each question. Chapter 16 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Explain the way vaporization and steam relate to the extinguishing properties of water.

More information

COUNTER CURRENT UNIT. Instruction Manual

COUNTER CURRENT UNIT. Instruction Manual COUNTER CURRENT UNIT Instruction Manual 1 Introduction: Congratulations on your purchase of a new Certikin counter current swimming unit. This unit has been developed and built by qualified personnel especially

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 4 Guidelines for Equipment on Fire Fighting Ships Edition 2008 The following Guidelines come into

More information

Emergency Water Injection /28/2017 updated 07/21/2017

Emergency Water Injection /28/2017 updated 07/21/2017 Emergency Water Injection 101 06/28/2017 updated 07/21/2017 Written By: Ronald D. Huffman, www.respondertraining.com When something happens and you're faced with an uncontrollable liquid propane leak you

More information

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR VOLUME XIV, ISSUE 1 FIRE HOSE AND NOZZLES JANUARY 1993 FIRE HOSE AND NOZZLES This is a two-part lesson covering Fire Hose and Nozzles.

More information

ELKHART BRASS MANUFACTURING COMPANY

ELKHART BRASS MANUFACTURING COMPANY ELKHART BRASS MANUFACTURING COMPANY INSTALLATION and OPERATING INSTRUCTIONS for MODEL UP PRESSURE RESTRICTING HOSE VALVES I. Models and Sizes Covered: UP-20, 1-1/2" size UP-25, 1-1/2" size UP-20, 2-1/2"

More information

Design Requirements for Eyewash and Safety Shower Units

Design Requirements for Eyewash and Safety Shower Units Design Requirements for Eyewash and Safety Shower Units Application: Eyewash Stations must be provided in the following areas. Laboratories Plumbed emergency eyewash equipment shall be installed in every

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1019 - REVISED: 2011 Wall Hydrant with Backflow Protection and Freeze Resistance MANUFACTURER: CONTACT PERSON: E-MAIL:

More information

PUMP OPERATIONS SAN FRANCISCO FIRE DEPARTMENT

PUMP OPERATIONS SAN FRANCISCO FIRE DEPARTMENT PUMP OPERATIONS SAN FRANCISCO FIRE DEPARTMENT Blank page Pump Operations January 2008 San Francisco Fire Department 698 2 nd Street San Francisco, CA 94107 Chief of Department Joanne Hayes-White Manual

More information

Water Thiefs APPLIANCES APPLIANCES WATER THIEFS

Water Thiefs APPLIANCES APPLIANCES WATER THIEFS WATER THIEFS Water Thiefs A Water Thief allows the fire professional to extend attack lines from a main supply line. Elkhart s selection of Water Thief options includes Storz connectors which, when combined

More information