1 Internal Quality Assurance Jenny Andrews Secretary of the BSAC Working Party on Susceptibility Testing

2 Data provided by the BSAC Acceptable MIC ranges for control strains Acceptable zone diameter ranges for susceptible control strains Acceptable zone diameter ranges for control strains with a mechanism of resistance

3 To be remembered Acceptable ranges are for use with the BSAC Standardized Methods ONLY Do not assume that MIC values are always the same on Iso-Sensitest agar & Mueller Hinton agar (MHA) e.g. azithromycin MICs for Salmonella typhi are higher on Mueller Hinton agar than on Iso-Sensitest agar. In this case there is an impact on the MIC BP used to interpret susceptibility and isolates may appear resistant when tested on MHA (Przybylo, Burns & Qamruddin JAC 2012). Acceptable zone diameter ranges for control strains are affected by test conditions e.g. size of inoculum (BSAC = semi-confluent growth, EUCAST = confluent growth), medium etc. Acceptable ranges for control strains (and zone diameter BPs for tests) cannot be used with other standardized methods

4 Table 2a: Susceptible control strains or control strains with low-level resistance that have been chosen to monitor test performance of antimicrobial susceptibility testing Organism Either Or Characteristics Escherichia coli NCTC (ATCC 25922) Staphylococcus aureus NCTC (ATCC 25923) Pseudomonas aeruginosa NCTC (ATCC 27853) Enterococcus faecalis NCTC (ATCC 29212) NCTC NCTC 6571 NCTC Susceptible Susceptible Susceptible Susceptible Haemophilus influenzae NCTC Susceptible Streptococcus pneumoniae NCTC (ATCC 49619) Neisseria gonorrhoeae NCTC (ATCC 49226) Low-level resistant to penicillin Low-level resistant to penicillin Pasteurella multocida NCTC 8489 Susceptible Bacteroides fragilis NCTC 9343 (ATCC 25285) Susceptible Bacteroides thetaiotaomicron ATCC Susceptible Clostridium perfringens NCTC 8359 (ATCC 12915) Susceptible

5 Table 2b: Control strains with a resistance mechanism that can be used to confirm that the method will detect resistance Organism Strain Characteristics Escherichia coli NCTC TEM-1 ß- lactamaseproducer Staphylococcus aureus NCTC MecA positive, methicillin resistant Haemophilus influenzae NCTC (ATCC 49247) Resistant to ß- lactams (ßlactamasenegative)

6 BSAC Acceptable MIC Ranges for Control Strains Control of MIC Determinations Tables 7-10 provide target MIC (mg/l) values for recommended control strains by BSAC methodology. MICs should be within one two-fold dilution of the target values i.e. target MIC 1 mg/l acceptable range mg/l.

7 Source of Zone Diameter Data BSAC Field Study (5 members of the Working Party & 14 diagnostic laboratories) Rolling programmes (25 diagnostic laboratories) e.g. 10 laboratories acceptable ranges for 12 agents v N. gonorrhoeae Diagnostic Laboratories e.g. New Cross Hospital in Wolverhampton, Withington Hospital in Manchester NB. The BSAC welcome any zone data for control strains

8 Calculation of 2.5 and 97.5 percentile points, to obtain a range encompassing 95% of observations Obtain at least 100 observations (zone diameters mm) for the control strain tested by BSAC methodology. Zone diameter (mm) No. Observations Cumulative No. Observations Cumulative % Statistical advice Dr. T. Marshall Birmingham University

9 Example of plot of zone diameter v cumulative percentage Cumulative % Zone diameter (mm) Acceptable range mm

10 Rolling programme: Confirmation of acceptable range E. coli ATCC 25922: ampicillin 25 ug disc CT25 (Oxoid) CT1 (Oxoid) CT24 (In-house) CT6 (Oxoid) CT2 (Oxoid) Centre Each centre undertook 50 tests on different occasions

11 Rolling programme: Confirmation of acceptable range E. coli NCTC 10418: 75 ug piperacillin disc. Zone diameter (mm) CT4 (in-house) CT8 (Oxoid) CT20 (biomerieux) CT14 (Oxoid) CT12 (in-house) Centre Each centre undertook 50 tests on different occasions

12 Use of control data to monitor the performance of disc diffusion tests Testing is acceptable if no more than1 in every 20 results is outside the limits of acceptability. If 2 or more results fall out of the acceptable range this requires immediate investigation. Look for trends within the limits of acceptability e.g. tendency for zones to be at the limits of acceptability; tendency for zones to be consistently above or below the mean; gradual drift in zone diameters. Quality Assurance will often pick up trends before the controls go out of range. Prepared by Trevor Winstanley for the BSAC recommendations

13 Potential sources of error in disc diffusion antimicrobial susceptibility testing: Test conditions Excessive pre-incubation before discs applied Excessive pre-diffusion before plates incubated Incorrect incubation temperature (35 0 C for cefoxitin v staphylococci) Incorrect incubation atmosphere (false metronidazole R ) Incorrect incubation time (VanB resistance in enterococci) Inadequate illumination of plates when reading Incorrect reading of zone edges (cefoxitin for the detection of MRSAs) Incorrect template (wrong agent or wrong version of the guidelines) Prepared by Trevor Winstanley for the BSAC recommendations

14 Potential sources of error in disc diffusion antimicrobial susceptibility testing: medium Required susceptibility testing agar not used Not prepared as required by the manufacturer s instructions Batch to batch variation Antagonists present (e.g. with sulphonamides and trimethoprim) Incorrect ph Incorrect divalent cation concentration (can be an issue when testing daptomycin by gradient methods need 50 mg/l calcium in the medium) Incorrect depth of agar plates (4mm ± 0.5 mm) Agar plates not level Expiry date exceeded Prepared by Trevor Winstanley for the BSAC recommendations

15 Potential sources of error in disc diffusion antimicrobial susceptibility testing: antimicrobial discs Wrong agent or content used Labile agent possibly deteriorated Light sensitive agent left in light Incorrect storage leading to deterioration Disc containers opened before reaching room temperature Incorrect labelling of disc dispensers Expiry date exceeded Prepared by Trevor Winstanley for the BSAC recommendations

16 Potential sources of error in disc diffusion antimicrobial susceptibility testing: control strains Contamination Mutation Incorrect inoculum density Uneven inoculation Old culture used (maintenance of control strains available on the BSAC web site) Prepared by Trevor Winstanley for the BSAC recommendations

17 Reporting Susceptibility Results when Controls Indicate Problems Microbiologists must use a pragmatic approach, as results from repeat testing are not available on the same day. If results with control strains are out of range the implications for test results need to be assessed. Control results out of range If control zones are below range but test results are susceptible, or control zones are above range but test results are resistant, investigate possible sources of error but report the test results. Otherwise it may be necessary to suppress reports on affected agents, investigate and retest. Atypical results If results are atypical with clinical isolates, the purity of the isolate and identification should be confirmed and the susceptibility repeated. Suppress the results for individual agents and retest. Prepared by Trevor Winstanley for the BSAC recommendations

18 What to do if the problem is not resolved Contact the BSAC (HQ or the Secretary of the Working party) BSAC will forward the information to the appropriate manufacturer for their comment

19 Conclusion: BSAC Provides A list of susceptible control strains for monitoring performance A list of control strains with a resistance mechanism that can be used to confirm that the method will detect resistance Acceptable MIC ranges for control strains Acceptable zone diameter ranges for control strains

20 Conclusion: BSAC Provides Advice on how to monitor the performance of disc testing Advice on the investigations that are necessary if the control data indicates there is a problem Advice on reporting susceptibility results when controls indicate a problem Support for laboratories that cannot resolve problems with control strain performance

Analysis of the Comparative Workflow of the VITEK 2 and the Phoenix System

Analysis of the Comparative Workflow of the VITEK 2 and the Phoenix System Annual Meeting of the American Society for Microbiology Paper C-250 May, 2003, Washington, DC Analysis of the Comparative Workflow of the VITEK 2 and the System U. Eigner, A. Caganic, U. Wild, D. Bertsch,

More information

What surveillance do we have for AMR?

What surveillance do we have for AMR? What surveillance do we have for AMR? Dr Berit Muller-Pebody AMR Section Lead, HCAI & AMR Department National Infection Service, Public Health England Better access and use of surveillance data English

More information

Invasive Bacterial Disease Surveillance Report Emerging Infections Program Minnesota Department of Health

Invasive Bacterial Disease Surveillance Report Emerging Infections Program Minnesota Department of Health Invasive Bacterial Disease Surveillance Report 2009 Emerging Infections Program Minnesota Department of Health Surveillance Methods Cases include Minnesota residents with invasive infections due to Group

More information

1. INTRODUCTION 2. THE PURPOSE OF THE USER GUIDE 3. CONTACT 4. INSTRUCTIONS FOR USE. 4.1 How to access the BSAC Resistance Surveillance Database

1. INTRODUCTION 2. THE PURPOSE OF THE USER GUIDE 3. CONTACT 4. INSTRUCTIONS FOR USE. 4.1 How to access the BSAC Resistance Surveillance Database DATABASE USER GUIDE TABLE OF CONTENTS 1. Introduction... 3 2. The purpose of the User Guide... 3 3. Contact... 3 4. Instructions for use... 3 4.1 How to access the BSAC Resistance Surveillance Database...

More information

INVASIVE BACTERIAL DISEASE SURVEILLANCE REPORT, 2016

INVASIVE BACTERIAL DISEASE SURVEILLANCE REPORT, 2016 INVASIVE BACTERIAL DISEASE SURVEILLANCE REPORT, 26 Emerging Infections Program Active Bacterial Core Surveillance (ABCs) Minnesota Department of Health Diseases Included Group A Streptococcus page 5 Group

More information

INVASIVE BACTERIAL DISEASE SURVEILLANCE REPORT, 2010

INVASIVE BACTERIAL DISEASE SURVEILLANCE REPORT, 2010 INVASIVE BACTERIAL DISEASE SURVEILLANCE REPORT, Emerging Infections Program Active Bacterial Core Surveillance (ABCs) Minnesota Department of Health Diseases included Group A Streptococcus page 5 Group

More information

Detection of Micro-organisms in Compressed Gases

Detection of Micro-organisms in Compressed Gases Detection of Micro-organisms in Compressed Gases H. Zingre 1, R. Meier 2, h.zingre@mbv.ch, r.meier@mbv.ch Abstract MBV AG, Stäfa, Switzerland The International Standard ISO 14698-1/2 1 demands the monitoring

More information

National surveillance services a helpful investment in educating healthcare professionals

National surveillance services a helpful investment in educating healthcare professionals National surveillance services a helpful investment in educating healthcare professionals Neil Woodford Head, Antimicrobial Resistance & Healthcare Associated Infections (AMRHAI) Reference Unit Crown Copyright

More information

Antimicrobial Resistance in the UK

Antimicrobial Resistance in the UK Antimicrobial Resistance in the UK Neil Woodford Antimicrobial Resistance & Healthcare Associated Infections (AMRHAI) Reference Unit Crown copyright UK 5-year AMR Strategy 2013-18: Seven key areas for

More information

Height (ft) Find the average rebound percentage for your ball. Show your work.

Height (ft) Find the average rebound percentage for your ball. Show your work. Different balls bounce at various heights depending on things like the type of ball, the pressure of air in the ball, and the surface on which it is bounced. The rebound percentage of a ball is found by

More information

INFORMATION NOTE No 353: MICROBIOLOGICAL TESTING

INFORMATION NOTE No 353: MICROBIOLOGICAL TESTING INFORMATION NOTE No 353: MICROBIOLOGICAL TESTING First issued: January 2007 Updated: June 2010 ABOUT ISRM This is one of a series of Information Notes produced by the Institute of Sport and Recreation

More information

Height (ft) Find the average rebound percentage for your ball. Show your work.

Height (ft) Find the average rebound percentage for your ball. Show your work. Different balls bounce at various heights depending on things like the type of ball, the pressure of air in the ball, and the surface on which it is bounced. The rebound percentage of a ball is found by

More information

Surface disinfection process

Surface disinfection process SURFACE disinfection Surface disinfection process Contamination control, healthcare safety Aspergillus. Description of NF-T 72-281 ( Standard created by the French Health Authorities, the only one established

More information

Surface disinfection process

Surface disinfection process SURFACE disinfection Surface disinfection process Contamination control, healthcare safety Aspergillus. Description of NF-T 72-281 ( Standard created by the French Health Authorities, the only one established

More information

Laboratory Accreditation Programmes

Laboratory Accreditation Programmes Client No. 590 Private Bag 3205, Waikato Mail Centre, Hamilton, 3240 28 Duke St, Frankton, Hamilton, 3204 Telephone 0508 445-5522 www.hill-laboratories.com Fax Authorised Representative Ms Gillian Lees

More information

FOAM. Overview. Sterilast 1550 Tiburon Blvd, Suite G-325, Tiburon, CA Page 1 of 8

FOAM. Overview. Sterilast 1550 Tiburon Blvd, Suite G-325, Tiburon, CA Page 1 of 8 FOAM The information and recommendations ("Information") on this document are presented to you in good faith. This Information is believed to be correct, however, nor its affiliates makes no representations

More information

Pseudomonas aeruginosa Disinfection in Swimming Pool Water - Laboratory Efficacy Testing.

Pseudomonas aeruginosa Disinfection in Swimming Pool Water - Laboratory Efficacy Testing. TWEED LABORATORY CENTRE A COMMERCIAL UNIT OF THE TWEED SHIRE COUNCIL ABN 90 178 732 496 46 Enterprise Avenue, Tweed Heads South NSW 2486. Phone (07) 5569 3 100, Fax (07) 5524 2676 All correspondence: Tweed

More information

Country report. Swedish bathing water quality in Sweden. May Photo: Peter Kristensen/EEA

Country report. Swedish bathing water quality in Sweden. May Photo: Peter Kristensen/EEA Country report Swedish bathing water quality in 2017 Sweden May 2018 Photo: Peter Kristensen/EEA BWD Report For the Bathing Season 2017 Sweden The report gives a general overview of information acquired

More information

DRUG STABILITY AN EVIDENCE REVIEW AND DEVELOPMENT OF A NATIONAL METHODOLOGY FOR STABILITY TESTING OF AGENTS AND DEVICES

DRUG STABILITY AN EVIDENCE REVIEW AND DEVELOPMENT OF A NATIONAL METHODOLOGY FOR STABILITY TESTING OF AGENTS AND DEVICES DRUG STABILITY AN EVIDENCE REVIEW AND DEVELOPMENT OF A NATIONAL METHODOLOGY FOR STABILITY TESTING OF AGENTS AND DEVICES Mr Tim Hills Nottingham University Hospitals NHS Trust On behalf of the BSAC OPAT

More information

Proficiency Testing Corrective Action Checklist: PT PROVIDER: PT EVENT: TEST:

Proficiency Testing Corrective Action Checklist: PT PROVIDER: PT EVENT: TEST: Proficiency Testing Corrective Action Checklist: PT PROVIDER: PT EVENT: TEST: PT Process Package Received Who received it? Handling Upon arrival Was the kit cold? Was the kit damaged? Was the kit complete?

More information

Some information on Statistical Process Control (SPC) c charts that may be useful for clinical teams

Some information on Statistical Process Control (SPC) c charts that may be useful for clinical teams Some information on Statistical Process Control (SPC) c charts that may be useful for clinical teams Evonne Curran Nurse Consultant Infection Control Health Protection Scotland July 9 All the SPC charts

More information

TPM TIP. Oil Viscosity

TPM TIP. Oil Viscosity TPM TIP Oil Viscosity TIP #1 Classification according to viscosity is the most prevalent method of describing oils, and the most common classification systems are those of the SAE, AGMA, and ISO. Each

More information

Productivity. Technician. Maximized. Interpretation Guide. 3M Food Safety 3M Petrifilm Salmonella Express System

Productivity. Technician. Maximized. Interpretation Guide. 3M Food Safety 3M Petrifilm Salmonella Express System M Food Safety M Petrifilm Salmonella Express System Technician Productivity Maximized Interpretation Guide M Petrifilm Salmonella Express (SALX) System is a qualitative pathogen test used for the rapid

More information

Denise L Seman City of Youngstown

Denise L Seman City of Youngstown Denise L Seman City of Youngstown The control chart is one of the most important tools of quality control for laboratory data. A control chart is a specific kind of run chart that allows unusual change

More information

SALX. Interpretation Guide. Salmonella Express System

SALX. Interpretation Guide. Salmonella Express System Interpretation Guide M Petrifilm Salmonella Express System is a qualitative pathogen test used for the rapid detection and biochemical confirmation of Salmonella in enriched foods and food process environmental

More information

OECD GUIDANCE DOCUMENT FOR DEMONSTRATING EFFICACY OF POOL AND SPA DISINFECTANTS IN LABORATORY AND FIELD TESTING

OECD GUIDANCE DOCUMENT FOR DEMONSTRATING EFFICACY OF POOL AND SPA DISINFECTANTS IN LABORATORY AND FIELD TESTING OECD GUIDANCE DOCUMENT FOR DEMONSTRATING EFFICACY OF POOL AND SPA DISINFECTANTS IN LABORATORY AND FIELD TESTING DRAFT 21 ST SEPTEMBER 2010 1 GUIDANCE DOCUMENT FOR DEMONSTRATING EFFICACY OF POOL AND SPA

More information

Statistical Method Certification, Coal Combustion Residuals Landfill, Reid Gardner Generating Station

Statistical Method Certification, Coal Combustion Residuals Landfill, Reid Gardner Generating Station TECHNICAL MEMORANDUM Statistical Method Certification, Coal Combustion Residuals Landfill, Reid Gardner Generating Station PREPARED FOR: PREPARED BY: REVIEWED BY: NV Energy Nathan Betts, PE/CH2M Charles

More information

Application of nanosilver in swimming pool water treatment technology

Application of nanosilver in swimming pool water treatment technology Application of nanosilver in swimming pool water treatment technology Joanna Wyczarska-Kokot and Florian Piechurski Silesian University of Technology Institute of Water and Wastewater Engineering Poland

More information

Drug Stability : Update and future plans. Tim Hills Nottingham University Hospitals NHS Trust On behalf of the BSAC Working Party on Drug Stability

Drug Stability : Update and future plans. Tim Hills Nottingham University Hospitals NHS Trust On behalf of the BSAC Working Party on Drug Stability Drug Stability : Update and future plans. Tim Hills Nottingham University Hospitals NHS Trust On behalf of the BSAC Working Party on Drug Stability BSAC Drug Stability Workstream Update of progress so

More information

ANNUAL SUMMARY OF INFECTIOUS DISEASES OHIO 2014

ANNUAL SUMMARY OF INFECTIOUS DISEASES OHIO 2014 OHIO DEPARTMENT OF HEALTH ANNUAL SUMMARY OF INFECTIOUS DISEASES OHIO 2014 REPORTED INCIDENCE OF SELECTED NOTIFIABLE DISEASES PREPARED AND DISTRIBUTED BY: BUREAU OF INFECTIOUS DISEASES TABLE OF CONTENTS

More information

4 CONTROL-CHART EXAMPLES

4 CONTROL-CHART EXAMPLES 4 CONTROL-CHART EXAMPLES The following charts are examples of how various conditions will affect your control plots. They are intended only as a guide; your plot may not look exactly like these examples.

More information

Formation of Nudicaulins In Vivo and In Vitro and the Biomimetic Synthesis and Bioactivity of O-Methylated Nudicaulin Derivatives

Formation of Nudicaulins In Vivo and In Vitro and the Biomimetic Synthesis and Bioactivity of O-Methylated Nudicaulin Derivatives Formation of Nudicaulins In Vivo and In Vitro and the Biomimetic Synthesis and Bioactivity of O-Methylated Nudicaulin Derivatives Bettina Dudek 1,, Florian Schnurrer 1,, Hans-Martin Dahse 2, Christian

More information

EUSMUNC06 (SQA Unit Code - FG2W 04) Locate and avoid supply apparatus for Utilities Network Construction

EUSMUNC06 (SQA Unit Code - FG2W 04) Locate and avoid supply apparatus for Utilities Network Construction Locate and avoid supply apparatus for Utilities Network Construction Overview This national occupational standard defines the competence involved in locating and avoiding supply apparatus by using appropriate

More information

Productivity. Technician. Maximized. Interpretation Guide

Productivity. Technician. Maximized. Interpretation Guide 3M Food Safety 3M Petrifilm Aqua Enterobacteriaceae Count Plate 3M Petrifilm Aqua Yeast and Mold Count Plate Technician Productivity Maximized Interpretation Guide Introducing 3M Petrifilm Aqua Plates

More information

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION Approved By: Senior Manager: Mpho Phaloane Revised By: Field Manager: Neville Tayler Date of Approval: 2015-08-26 Date of Implementation: 2015-08-26

More information

THE NUMBER OF COLONIES ALLOWABLE ON SATISFACTORY AGAR PLATES. counts is the limit in the number of colonies that may be allowed

THE NUMBER OF COLONIES ALLOWABLE ON SATISFACTORY AGAR PLATES. counts is the limit in the number of colonies that may be allowed THE NUMBER OF COLONIES ALLOWABLE ON SATISFACTORY AGAR PLATES ROBERT S. BREED AND W. D. DOTTERRER' New York Agricultural Experiment Station, Geneva, New York INTRODUCTION A point which is of much importance

More information

SAFETY DATA SHEET. according to Regulation (EC) No. 2015/830

SAFETY DATA SHEET. according to Regulation (EC) No. 2015/830 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING 1.1 Product identifiers Product name (dehydrated media): Product name (bottled media): Product name (plated media): Code number:

More information

Controls and Control Charting

Controls and Control Charting Controls and Control Charting Control Charts and Trend Analysis for ISO/IEC 17025:2005 www.aphl.org Abbreviation and Acronyms CRM-Certified Reference Materials RM-Reference Materials PT-Proficiency Test(ing)

More information

Effects of Relative Humidity, Concentration, and Exposure Time on the Efficacy of Chlorine Dioxide Gas Decontamination

Effects of Relative Humidity, Concentration, and Exposure Time on the Efficacy of Chlorine Dioxide Gas Decontamination Revision Date: October 15, 2006 American Biological Safety Association 49th Annual Biological Safety Conference Effects of Relative Humidity, Concentration, and Exposure Time on the Efficacy of Chlorine

More information

General Policies July Hydrotherapy Pool Policy

General Policies July Hydrotherapy Pool Policy Hydrotherapy Pool Policy HYDROTHERAPY POOL POLICY Contra-indications to a User with the advice of a Doctor, the School Nurse and/or Physiotherapist: Infectious skin disease Infectious upper respiratory

More information

Bacterial retention within a multi-layered absorbent AIRLOCK Technology Single Use Negative Pressure Wound Therapy (snpwt) dressing

Bacterial retention within a multi-layered absorbent AIRLOCK Technology Single Use Negative Pressure Wound Therapy (snpwt) dressing 1/5 Introduction The dressing with AIRLOCK Technology* helps promote wound healing in low to moderate exuding wounds; it is a four-layer dressing that ensures negative pressure is delivered to the wound

More information

Developing a HACCP plan

Developing a HACCP plan Developing a HACCP plan Adapted from the Food and Agriculture Organisation of the UNITED NATIONS, department of Agriculture and Consumer protection: Manual on the application of the HACCP system in Mycotoxin

More information

Quality Assurance Charting for QC Data

Quality Assurance Charting for QC Data Quality Assurance Charting for QC Data September 2018 Iowa s Environmental & Public Health Laboratory Copyright the State Hygienic Laboratory at the University of Iowa 2017. All rights reserved. Images

More information

IOWA HIGH SCHOOL ATHLETIC ASSOCIATION REVIEW OF BLOOD-BORNE PATHOGEN PROCEDURES

IOWA HIGH SCHOOL ATHLETIC ASSOCIATION REVIEW OF BLOOD-BORNE PATHOGEN PROCEDURES REVIEW OF BLOOD-BORNE PATHOGEN PROCEDURES I. Host schools are expected to designate a trained individual to properly handle situations involving blood and other body fluids which contaminate any part of

More information

CASE STUDY ON RISK ASSESSMENTS FOR CROSS CONTAMINATION. Stephanie Wilkins, PE EMA Workshop June 2017

CASE STUDY ON RISK ASSESSMENTS FOR CROSS CONTAMINATION. Stephanie Wilkins, PE EMA Workshop June 2017 CASE STUDY ON RISK ASSESSMENTS FOR CROSS CONTAMINATION Stephanie Wilkins, PE EMA Workshop 20-21 June 2017 Objectives How the process is embedded into the QMS Case study to show: Use of data to assess occurrence

More information

Photobacterium damselae piscicida

Photobacterium damselae piscicida Aquaculture Sci. 61 2 163 169 2013 Photobacterium damselae piscicida 1, 1 2 3 4 4 5 6 7 7 1 Antimicrobial Susceptibility and Molecular Diversity of Photobacterium damselae subsp. piscicida Isolated in

More information

CGMP KITS PROTOCOL ASSAY PRINCIPLE

CGMP KITS PROTOCOL ASSAY PRINCIPLE CGMP KITS PROTOCOL Part # 62GM2PEG & 62GM2PEH Test size#: 500 tests (62GM2PEG), 10,000 tests (62GM2PEH) - assay volume: 20 µl Revision: 02-Jan.2018 Store at: 2-8 C (62GM2PEG); 2-8 C (62GM2PEH) For research

More information

NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A Direct heat Microbiological co 2 incubators NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com In-VitroCell NU-5800 Series Direct Heat Microbiological Incubators The

More information

OPERATING INSTRUCTIONS Sherlock Chamber Testing System

OPERATING INSTRUCTIONS Sherlock Chamber Testing System OPERATING INSTRUCTIONS Sherlock Chamber Testing System Arrangement Equipment Kit FL90 & FL100 Corbel Test Plate with Gasket Seal S8, S14, S15 & S16 Sump Test Plate with Gasket Seal S7 & S5 Chamber Test

More information

FISH 415 LIMNOLOGY UI Moscow

FISH 415 LIMNOLOGY UI Moscow Sampling Equipment Lab FISH 415 LIMNOLOGY UI Moscow Purpose: - to familiarize you with limnological sampling equipment - to use some of the equipment to obtain profiles of temperature, dissolved oxygen,

More information

A Quick Reference Guide to Some Processing Problems and Corrective Actions:

A Quick Reference Guide to Some Processing Problems and Corrective Actions: A Quick Reference Guide to Some Processing Problems and s: Color Negative Film Process - C41, C41B, C41RA Color Print Paper Process - EP2, RA4 Several variables in processing can affect the final quality

More information

HUMAN IL6 KITS PROTOCOL

HUMAN IL6 KITS PROTOCOL HUMAN IL6 KITS PROTOCOL Part # 62HIL06PEG & 62HIL06PEH Test size: 500 tests (62HIL06PEG), 10,000 tests (62HIL06PEH) - assay volume: 20 µl Revision: 04 (Jan. 2018) Store at: -60 C or below This product

More information

Tools to Enhance Laboratory Biosafety and Biosecurity Performing Risk Assessments

Tools to Enhance Laboratory Biosafety and Biosecurity Performing Risk Assessments Tools to Enhance Laboratory Biosafety and Biosecurity Performing Risk Assessments Selection of Safety Practices Biosecurity in the Laboratory Safety Orientation and Training Biosafety Competencies Audits,

More information

The Water O 3. zonator. Model WOZ3 Manual CONTENTS

The Water O 3. zonator. Model WOZ3 Manual CONTENTS zonator Model WOZ3 Manual CONTENTS WELCOME TO SOTA... 2 BEFORE USING... 2 LEARN MORE... 2 COMPLETE UNIT INCLUDES... 2 DO NOT USE... 3 CAUTIONS... 3 SUMMARY OF LIGHTS... 3 HOW TO USE THE WATER OZONATOR...

More information

SEPSIS SYMPOSIUM 23 RD INFECTION AND MARCH 2018 SHERATON PORTO CONGRESS COURSES: MAIN TOPICS:

SEPSIS SYMPOSIUM 23 RD INFECTION AND MARCH 2018 SHERATON PORTO CONGRESS COURSES: MAIN TOPICS: CONGRESS COURSES: ANTIBIOTIC THERAPY COURSE 09-10 MARCH HOSPITAL LUSÍADAS PORTO MAIN TOPICS: ANTIBIOTIC STEWARDSHIP - LESSONS LEARNED - IMPLEMENTING SUCCESSFUL PROGRAMS - ENGAGING KEY STAKEHOLDERS CHALLENGING

More information

Supplementary Information

Supplementary Information Supplementary Information Vitroprocines, new antibiotics against Acinetobacter baumannii, discovered from marine Vibrio sp. QWI 6 using mass spectrometry based metabolomics approach Chih Chuang Liaw 1,2,3

More information

USP <797> LABELING ESTABLISHING BEYOND-USE DATES AND IN-USE TIMES

USP <797> LABELING ESTABLISHING BEYOND-USE DATES AND IN-USE TIMES USP LABELING ESTABLISHING BEYOND-USE DATES AND IN-USE TIMES Each CSP label must state the date beyond which the preparation cannot be used and must be discarded. A CSP may also be labeled with an

More information

Active Fire Prevention by Oxygen Reduction Systems

Active Fire Prevention by Oxygen Reduction Systems Active Fire Prevention by Oxygen Reduction Systems Markus Mueller Wagner Schweiz AG, Wallisellen, Switzerland Abstract After more than 15 years, active fire prevention by Oxygen reduction systems has become

More information

Section1. Knowledge of RPE Sets out the minimum knowledge requirements in respect of respiratory protective equipment. [Mandatory] 1.

Section1. Knowledge of RPE Sets out the minimum knowledge requirements in respect of respiratory protective equipment. [Mandatory] 1. Subject / Content Section1. Knowledge of RPE Sets out the minimum knowledge requirements in respect of respiratory protective equipment. [Mandatory] 1.1 A general understanding of RPE use in the workplace

More information

Country report. Austrian bathing water quality in Austria. May Photo: Peter Kristensen

Country report. Austrian bathing water quality in Austria. May Photo: Peter Kristensen Country report Austrian bathing water quality in 2016 Austria May 2017 Photo: Peter Kristensen BWD Report For the Bathing Season 2016 Austria The report gives a general overview of information acquired

More information

Parallel Session 1A Sterile Manufacture. Denise Coakley. GMP Conference 12 th November 2014

Parallel Session 1A Sterile Manufacture. Denise Coakley. GMP Conference 12 th November 2014 Visual nspection Parallel Session 1A Sterile Manufacture Denise Coakley GMP Conference 12 th November 2014 EU GMP Annex 1: Filled containers of parenteral products should be inspected individually for

More information

Instructions for SOTA Water Ozonator Model WOZ5

Instructions for SOTA Water Ozonator Model WOZ5 Instructions for SOTA Water Ozonator Model WOZ5 CONTENTS INTRODUCTION... 2 LEARN MORE... 2 COMPLEMENTARY UNITS... 2 COMPLETE UNIT INCLUDES... 2 DO NOT USE... 3 CAUTIONS... 3 SUMMARY OF LIGHTS... 3 HOW

More information

Installation Procedure Esco Miri Multi-Room Incubator

Installation Procedure Esco Miri Multi-Room Incubator Esco Miri Multi-Room Incubator Version 1.1 ESCO MEDICAL Esco Micro Pte Ltd 21 Changi South Street 1 Singapore 486777 Tel. : +65 6542 0833 Fax : +65 6542 5732 / 6546 2913 Mail : csis-medical@escoglobal.com

More information

Seal Extension Guidelines. Asset Management and Systems

Seal Extension Guidelines. Asset Management and Systems Seal Extension Guidelines 1. Guideline Definitions AADT - Annual Average Daily Traffic is measured at regular annual (or greater) intervals and adjusted for seasonal effects, using an approved traffic

More information

What is the D-ifference in D-value?

What is the D-ifference in D-value? Volume 3, Number 3 September 2006 Garrett Krushefski Scientific & Technical Services Manager What is the D-ifference in D-value? Occasionally our Customer Service Department receives a request for biological

More information

Bacteriological Quality Assessment of swimming pools in the Osu- Labadi Area, Accra

Bacteriological Quality Assessment of swimming pools in the Osu- Labadi Area, Accra Bacteriological Quality Assessment of swimming pools in the Osu- Labadi Area, Accra George Osei-Adjei 1*, Simon Kwabena Sarpong 2, Emmanuel Laryea 1, Emmanuel Tagoe 1 1. Accra Polytechnic, School of Applied

More information

MOLEBIO LAB #1: Microquantity Measurement

MOLEBIO LAB #1: Microquantity Measurement MOLEBIO LAB #1: Microquantity Measurement Introduction: This lab introduces micropipetting and sterile pipetting techniques used throughout this course. Mastery of these techniques is important for good

More information

FISH 415 LIMNOLOGY UI Moscow

FISH 415 LIMNOLOGY UI Moscow FISH 415 LIMNOLOGY UI Moscow Sampling Equipment Purpose: - to familiarize you with limnological sampling equipment - to use some of the equipment to obtain profiles of temperature, dissolved oxygen, conductivity

More information

Effect of Diving and Diving Hoods on the Bacterial Flora of the External Ear Canal and Skin

Effect of Diving and Diving Hoods on the Bacterial Flora of the External Ear Canal and Skin JOURNAL OF CLINICAL MICROBIOLOGY, May 1982, p. 855-859 0095-1137/82/050855-05$02.00/0 Vol. 15, No. 5 Effect of Diving and Diving Hoods on the Bacterial Flora of the External Ear Canal and Skin ITZHAK BROOK,'*

More information

130 SSP Soluble Salt Profiler

130 SSP Soluble Salt Profiler 130 SSP Soluble Salt Profiler Conforms to: SSPC Guide 15, Bresle Equivalent ISO 8502-9 Test Method Page 1 of 6 The Elcometer 130 Soluble Salt Profiler provides fast and accurate measurement of the level

More information

Best Practice for Calibrating LTH Conductivity Instruments

Best Practice for Calibrating LTH Conductivity Instruments Application Note Best Practice for Calibrating LTH Conductivity Instruments As accurate process measurement becomes an everyday requirement it is vital to be able to calibrate conductivity instruments

More information

See if you can determine what the following magnified photos are. Number your paper to 5.

See if you can determine what the following magnified photos are. Number your paper to 5. Challenge 7 See if you can determine what the following magnified photos are. Number your paper to 5. The Answers: EXPERIMENTAL DESIGN Science answers questions with experiments DEFINE THE PROBLEM Begin

More information

Studies on a rapid immuno-chromatographic detection system for Shiga toxins and the E. coli O157 antigen

Studies on a rapid immuno-chromatographic detection system for Shiga toxins and the E. coli O157 antigen BUNESINSTITUT FÜR RISIKOBEWERTUNG Studies on a rapid immuno-chromatographic detection system for Shiga toxins and the E. coli O157 antigen Lothar Beutin, Ylanna Burgos & Markus Tzschoppe National Reference

More information

PROFICIENCY TESTING 2015

PROFICIENCY TESTING 2015 Veterinary and Agrochemical Research Centre Groeselenberg 99 B 1180 Brussels (Ukkel) Tel: +32 (0)2 379 04 11 Fax : + 32 (0)2 379 06 70 http: // www.coda-cerva.be PROFICIENCY TESTING 2015 SALMONELLA (SAL)

More information

MediZAR. MediZar Sanitiser Products Ltd.

MediZAR. MediZar Sanitiser Products Ltd. What is MediZar? MediZar is a hygiene revolution a powerful, gentle and long lasting sanitiser certified to kill MRSA and E.Coli in 30 seconds, and will kill 99.9999% of harmful and deadly bacteria & viruses

More information

STAT 115 : INTRO TO EXPERIMENTAL DESIGN. Science answers questions with experiments

STAT 115 : INTRO TO EXPERIMENTAL DESIGN. Science answers questions with experiments STAT 115 : INTRO TO EXPERIMENTAL DESIGN Science answers questions with experiments 1 DEFINE THE PROBLEM Begin by asking a question about your topic What is a good question for an experiment? One that is

More information

Antibacterial properties of fish mucus from Channa punctatus and Cirrhinus mrigala

Antibacterial properties of fish mucus from Channa punctatus and Cirrhinus mrigala European Review for Medical and Pharmacological Sciences 2008; 12: 149-153 Antibacterial properties of fish mucus from Channa punctatus and Cirrhinus mrigala C. KUPPULAKSHMI, M. PRAKASH, G. GUNASEKARAN,

More information

The Relationship Between Automation Complexity and Operator Error

The Relationship Between Automation Complexity and Operator Error The Relationship Between Automation Complexity and Operator Error presented by Russell Ogle, Ph.D., P.E., CSP rogle@exponent.com (630) 274-3215 Chemical Plant Control Control physical and chemical processes

More information

INSTruCTIONS FOr SOTa WaTEr O ZONaTOr model WOZ5 CONTENTS INTrOduCTION COmplEmENTary units

INSTruCTIONS FOr SOTa WaTEr O ZONaTOr model WOZ5 CONTENTS INTrOduCTION COmplEmENTary units INSTRUCTIONS FOR SOTA WATER O 3 ZONATOR MODEL WOZ5 CONTENTS Introduction... 1 Complementary units... 1 COMPLETE UNIT INCLUDES... 2 ozonating WATER... 2 TIMING TO SATURATE WITH OZONE... 3 HOW MUCH TO DRINK...

More information

Bathing Water Directive report Greece

Bathing Water Directive report Greece Bathing Water Directive report 2013 Greece The report gives a general overview of information acquired from the reported data, based on provisions of the Bathing Water Directive 1. The reporting process

More information

Independent Health Facilities

Independent Health Facilities Independent Health Facilities Assessment Protocol for Pulmonary Function Studies - Technologist Assessor INSTRUCTIONS: Please complete ( ) the attached protocol during the assessment. Ensure that all the

More information

Procedure Instruction of program Pressurized Enclosure - Test Round 2017

Procedure Instruction of program Pressurized Enclosure - Test Round 2017 Procedure Instruction of program Pressurized Enclosure - Test Round 2017 Provider: Physikalisch-Technische Bundesanstalt Address: Bundesallee 100 38116 Braunschweig Country: Germany Place, date Braunschweig,

More information

SEMEEE36 Checking the compliance of electrical equipment against the specification

SEMEEE36 Checking the compliance of electrical equipment against the specification Checking the compliance of electrical equipment against the Overview This unit identifies the competences you need to carry out compliance checks on electrical equipment, in accordance with approved procedures.

More information

THE GATEWAY TO MICROBIOLOGY

THE GATEWAY TO MICROBIOLOGY Product Catalogue CONTENTS ORDERING INFORMATION 02 µprep READY-TO-RECONSTITUTE MEDIA 03 04 Harlequin chromogenic media 04 Dehydrated culture media 05 Media constituents 20 LYOPHILISED MEDIA SUPPLEMENTS

More information

HEALTH AND WATER QUALITY OF SWIMMING POOL: THE ITALIAN REGULATORY GUIDELINES

HEALTH AND WATER QUALITY OF SWIMMING POOL: THE ITALIAN REGULATORY GUIDELINES HEALTH AND WATER QUALITY OF SWIMMING POOL: THE ITALIAN REGULATORY GUIDELINES Emanuele Ferretti 1, *, Rossella Colagrossi 2 and Lucia Bonadonna 1 1 National Institute of Health (ISS), Department of Environment

More information

Convergent Technologys product overview

Convergent Technologys product overview Convergent Technologys product overview Lab Diagnostics - Convergys 1100-1001 Convergys ISE Analyzer 1100-1003 Convergys ISE Analyzer 3 electrodes out of (K+, Na+, Li+, CL-, Ca++, ph)* 5 electrodes out

More information

Microbiological Quality Assessment of Cultured Fish Samples Collected from Ponds and Different Local Markets of Bangladesh

Microbiological Quality Assessment of Cultured Fish Samples Collected from Ponds and Different Local Markets of Bangladesh Microbiological Quality Assessment of Cultured Fish Samples Collected from Ponds and Different Local Markets of Bangladesh G. M. M. Anwarul Hasan 1, Dr. Md. Sabir Hossain 2, Dr. Sahana Parveen 3, Dr. Farha

More information

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex.

USER MANUAL. 1. Principle of operation. 2. Delivery condition. SPRING-LOADED SAFETY VALVES zarmak. Edition: 07/2016 Date: V (ex. ZETKAMA Sp. z o.o. ul. 3 Maja 12 PL 57-410 Ścinawka Średnia SPRING-LOADED SAFETY VALVES zarmak USER MANUAL 782V (ex. 782) Edition: 07/2016 Date: 01.07.2016 TABLE OF CONTENTS 1. Principle of operation 2.

More information

Software Reliability 1

Software Reliability 1 Software Reliability 1 Software Reliability What is software reliability? the probability of failure-free software operation for a specified period of time in a specified environment input sw output We

More information

Real Time Water Quality Report Main River at Paradise Pool

Real Time Water Quality Report Main River at Paradise Pool Real Time Water Quality Report Main River at Paradise Pool Deployment Period 2010-08-24 to 2010-11-03 2011-01-05 Government of Newfoundland & Labrador Department of Environment and Conservation Water Resources

More information

EN ISO/IEC Technical Requirements

EN ISO/IEC Technical Requirements EN ISO/IEC 17025 - Technical Requirements Wolfgang Garche Environmental Protection Agency Department Air Quality Monitoring, Information, Assessment 1 What means accreditation in accordance to EN ISO/IEC

More information

Country report. Slovenian bathing water quality in Slovenia. May Photo: Peter Kristensen

Country report. Slovenian bathing water quality in Slovenia. May Photo: Peter Kristensen Country report Slovenian bathing water quality in 2016 Slovenia May 2017 Photo: Peter Kristensen BWD Report For the Bathing Season 2016 Slovenia The report gives a general overview of information acquired

More information

Material Safety Data Sheet

Material Safety Data Sheet Page 1/5 1 Identification of substance: Product details: Catalog or product number: 3100162, 9702516 Application of the substance / the preparation Laboratory chemicals Manufacturer/Supplier: Bio-Rad Laboratories,

More information

MICROBIOLOGICAL CO2 INCUBATORS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

MICROBIOLOGICAL CO2 INCUBATORS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com MICROBIOLOGICAL CO2 INCUBATORS NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. nuaire.com Microbiological Incubators Incubators In-VitroCell ES (Energy Saver) Incubators have been designed to

More information

Inquiry Investigation: Factors Affecting Photosynthesis

Inquiry Investigation: Factors Affecting Photosynthesis Inquiry Investigation: Factors Affecting Photosynthesis Background Photosynthesis fuels ecosystems and replenishes the Earth's atmosphere with oxygen. Like all enzyme-driven reactions, the rate of photosynthesis

More information

Perform Pressure & Leak Test, Tubing & Piping. Module 12306

Perform Pressure & Leak Test, Tubing & Piping. Module 12306 Perform Pressure & Leak Test, Tubing & Piping Module 12306 Instrumentation Trainee Task Module 12306 PERFORM PRESSURE AND LEAK TEST, TUBING AND PIPING Objectives Upon completion of this module, the trainee

More information

EUSCS04 Overseeing work in confined spaces

EUSCS04 Overseeing work in confined spaces Overview This unit is about the duties of a safety attendant (top-man/woman) which does not require entries into confined spaces. It is about controlling the pre-entry procedures and entry into and out

More information

BASICS of MAINTENANCE and TROUBLESHOOTING of VACUUM DIFFUSION PUMPS

BASICS of MAINTENANCE and TROUBLESHOOTING of VACUUM DIFFUSION PUMPS BASICS of MAINTENANCE and TROUBLESHOOTING of VACUUM DIFFUSION PUMPS Topics for Discussion Diffusion Pump Basics Maintenance Troubleshooting Topics for Discussion Diffusion Pump Fundamentals Maintenance

More information

Reliability Risk Management. August 2012 g Earl Shockley, Senior Director of Reliability Risk Management

Reliability Risk Management. August 2012 g Earl Shockley, Senior Director of Reliability Risk Management Reliability Risk Management Concept Models August 2012 g Earl Shockley, Senior Director of Reliability Risk Management Latent organizational weaknesses and conditions Deficiencies in Programmatic barriers

More information

PRODUCT GUIDE 2016/17. A Neogen Company THE GATEWAY TO MICROBIOLOGY

PRODUCT GUIDE 2016/17. A Neogen Company THE GATEWAY TO MICROBIOLOGY PRODUCT GUIDE 2016/17 A Neogen Company THE GATEWAY TO MICROBIOLOGY ABOUT LAB M Lab M specialises in microbiological culture media. The company develops, manufactures and supplies its products from its

More information