Chapter-7 Additional Studies

Size: px
Start display at page:

Download "Chapter-7 Additional Studies"

Transcription

1 Chapter-7 Additional Studies A. RISK ASSESSMENT 7.1 INTRODUCTION PAB Organic Pvt. Ltd. is an R&D based existing fine chemicals manufacturing company mainly involved in the manufacturing of N- Hydroxy Succinamide, 4 (1-Pyrrolidine) Butro Nitrile, 2-Chloro Ethylamine Hydrochloride, 4-Chloro Phenyl Hydrazine hydrochloride, 5 Amino Phthalide, 5 Bromo Phthalide, 1,3-Dihydro-1-Oxo-5-Isobenzofuran Carbonitrile (5-Cyano Phthalide), Schiff Base (1-Cyano(2,3 Dichlorophenyl Methalene Hydrazine)/Hydrazine Carboximidamide 2- [Cyano (2, 3-Di chlorophenyl)] Methylene and 4-(2,3 Epoxy Propoxy) Carbazole. Now, it has applied for expansion in 3 existing products, reduction in capacity of 6 products and addition of 39 new products as tabulated in Table Scope of Study The scope of work is to carry out risk analysis for the proposed expansion of plant covering all the hazardous chemicals to be handled and stored at the plant after expansion Study Objective The objective of the risk analysis includes the following: Identification of hazards Selection of credible scenarios Consequences Analysis of selected accidents scenarios Risk Mitigation Measures The Study Approach The risk assessment study broadly comprised of the following steps: System Description Identification of Hazards Selection of Credible Accident Scenarios Consequence Analysis Risk Mitigation Measures EIA report of PAB Organics Pvt. Ltd. 7-1

2 7.1.4 System Description This step comprised the compilation of the location, design and operational information needed for the risk analysis Identification of Hazards Hazards associated with the plant after expansion was identified. Summary of relevant accident cases was reviewed Selection of Accident Scenarios The release sources and potential accidents scenarios in the plant were listed. For each selected release source several scenarios were developed depending upon the failure mode causing loss of containment Consequence analysis Effects & consequence estimation were done to determine the potential for damage or injury from the selected scenarios. The incident outcomes were analyzed using release rate, dispersion, combustion and heat radiation and explosion models from fires Risk mitigation Measures Based on hazard identification and consequence analysis, risk reduction measures were suggested to reduce risk and enhance safety at the plant. 7.2 HAZARDOUS IDENTIFICATION Hazard is defined as a chemical or physical conditions those have the potential for causing damage to people, property or the environment. This chapter describes hazards associated with the plant after expansion due to handling and storage of hazardous chemicals. Maximum credible accidents scenarios involve in release of hazardous materials are selected and vulnerable zones are computed. Hazard identification is the first step in the risk analysis and entails the process of collecting information on: The types and quantities of hazardous substances stored and handled the location of storage tanks & other facilities, potential hazards associated with the spillage and release of hazardous chemicals. The assessment of vulnerable zones resulting from an accidental release of hazardous substance into the environment is one of the key elements of risk analysis. Quantification of the effects of such releases requires, data of EIA report of PAB Organics Pvt. Ltd. 7-2

3 the chemicals stored or handled in the area, quantities stored, operating parameters, quantity that would be released in case of an accident, meteorological conditions and physical attributes of the area. The starting point of risk analysis study is the identification of hazards and selection of scenarios that are then addressed for further consequence analysis. The proposed plant will be engaged in handling and storage of various flammable and toxic hazardous materials. Important characteristic of these hazardous materials are described in details below: Hazardous Substances to be handled at PAB Organics M/s. PAB Organics Pvt. Ltd. has been engaged in handling and storage of various flammable and toxic hazardous materials. Important characteristic of these hazardous materials are described in details below: Table 7.1 Main properties of Hazardous chemicals Hazardous Properties of Chemicals to be Consumed Sr. Name of Hazardous Chemicals BP 0 C FP 0 C LEL % UEL % TLV ppm LD 50 Oral mg/ Kg 1 IPA HCl Iso Valeraldhyde NA 5600 (Rat) 3 Methanol Tetrahydrofuran Acetone Acetonitrile Cyclohexane Ethyl Acetate LD 50 Dermal mg/kg [Rabbit] 2730 (Rabbit) [Rabbit] LC 50 mg/l 1562 ppm 4 hrs mg/m 3 (Rat) 4 hrs ppm 4 hours NA mg/m 3 NA 1250 [Rabbit] [Rabbit] Specific Gravity (water = 1) Vapour Density (air=1) Acute: mg/m 3 8 hours mg/l 96 hours [Fish (Fathea d Minnow) ] NA NA ppm EIA report of PAB Organics Pvt. Ltd. 7-3

4 Sr. Name of Hazardous Chemicals BP 0 C Hazardous Properties of Chemicals to be Consumed FP 0 C LEL % UEL % San Envirotech Pvt. Ltd., Ahmedabad TLV ppm LD 50 Oral mg/ Kg 9 Hexane Isopropyl alcohol Toluene Chloroform 61 NA NA NA LD 50 Dermal mg/kg LC 50 mg/l Specific Gravity (water = 1) Vapour Density (air=1) 6 hours NA ppm 4 hours NA [Rabbit] ppm 24 [Rabbit] hours [Mouse] >20000 [Rabbit] mg/m 3 4 hours 13 Nitric acid 121 NA NA NA 4 NA NA 244 ppm 0.5 hours 14 Hydrochloride Acid mm Hg 15 Cyclohexanone NA NA NA NA 900 [Rabbit ] Acetic acid Conc. Sulphuric Acid NA NA NA [Rat.] 18 Liquid Bromine NA NA NA NA 4701 ppm 0.5 hours 948 [Rabbit] 1060 [Rabbit] 510 mg/m 2 hours hours 5620 ppm 1 hours [Mouse ] 320 mg/m 3 2 hours [Mouse ] NA hours [Mouse ] 19 Thionyl Chloride 76 NA NA NA 1 NA NA 500 ppm 1 hours 20 n-butanol NA QUANTITIES OF HAZARDOUS MATERIALS 3400 [Rabbit] hours Many chemicals will be stored at the plant in small to large quantities as per requirement. Majority of chemicals are stored in very small quantities. After proposed expansion of the project, numbers of product will be formulated at the plant as per demand. As per Manufacture, Storage and EIA report of PAB Organics Pvt. Ltd. 7-4

5 Import of Hazardous Chemicals Rules, 1989 and amendment subsequently, there will be only few hazardous chemicals which have potential for creating risk to life and property in an unlikely event of leakage of spillage followed by fire. The bulk quantities of hazardous chemicals are stored at the plant in tank farm area with adequate dyke. Other chemicals will be stored in cylindrical tanks, barrels and carboys. Details of storage of hazardous materials are given in Table 7.2. Sr. Table 7.2: Facilities for Storage of Chemicals Name of hazardous substance State (Solid/ liquid/gas) Type of container MOC Max. Storage (MT) 1 IPA-HCl Liquid Drum HDPE Iso valeraldehyde Liquid Drum MS 40 3 Methanol Liquid Drum/Tank HDPE/MS 15 4 Tetra hydro furan Liquid Drum MS 2 5 Acetone Liquid Drum MS Acetonitrile Liquid Drum MS Cyclo hexane Liquid Drum MS 5 8 Ethyl acetate Liquid Drum MS 10 9 Hexane Liquid Drum MS IPA Liquid Drum MS Toluene Liquid Drum/Tank MS Chloroform Liquid Drum MS Nitric acid (98%) Liquid Carboys HDPE Conc. HCl Liquid Tank PP-FRP Cyclohexanone Liquid Drum MS 5 16 Acetic acid Liquid Drum HDPE Conc. sulphuric acid Liquid Tank PP-FRP Liq. Bromine Liquid Bottle Glass 1 19 Thionyl chloride Liquid Drum MS N-Butanol Liquid Drum HDPE HAZARDS DUE TO LOSS OF CONTAINMENT Hazardous chemicals to be handled and stored at the plant are in mostly liquids form. In the event of leakage or accidental release of these chemicals, it will create only localized effects within the short distances from fixed or spread pool in case of fire. There is possibility that release of some hazardous chemicals may cause as formation of vapour cloud which can move towards down wind direction and may explode in the event of EIA report of PAB Organics Pvt. Ltd. 7-5

6 fire if mass and concentration of air and vapour mixture is within the LEL and UEL limits. However, mass of vapour and air mixture may not adequate to generate explosive mass. Storage and handling of hazardous chemicals will not pose any hazardous situation if these are handled or stored correctly with adequate safety provisions and fire fighting facilities. Therefore, suitable safety measures including fire fighting facilities will be provided at the plant to attend any emergency due to accidental release of these hazardous chemicals. Among the hazardous inventories, there are few potential toxic materials which can form toxic vapour cloud in unlikely event of release. 7.5 MAXIMUM CREDIBLE ACCIDENT SCENARIOS The plant will be dealing with many hazardous substances described in details. Most of hazardous chemicals are in the form of liquid and considered as flammable and provided with dyke for loss of containment. Subsequently, their consequence due to thermal radiation will be confined within short distances. If released quantities are not ignited, therefore, vapour formation can result in vapour and air mixture and may generate explosive mass which can be explode if getting source of ignition. Toxic cloud of hazardous chemicals may also be formed and moved towards wind direction Methodology for Selection of Accident Scenarios In this study, following steps were followed for scenario selection for risk analysis study: The hazardous materials to be handled at the plant and the associated hazards have been identified and assessed. Operating and storage conditions of handling and storage of hazardous materials were studied. An assessment was made of what inventories can get released accidentally. Release rates were calculated considering deferent cases. For further analysis of selected release sources, representative failure modes and failure sizes were identified. EIA report of PAB Organics Pvt. Ltd. 7-6

7 7.5.2 Maximum Credible Accident Scenarios Following maximum credible scenarios have been selected for consequence analysis as a result of accidental releases: Sl. Type of Release Outcome Cases Considered 1. Release of Methanol Formation pool and thermal radiation from tank due to fire Vapour cloud explosion Dispersion of toxic cloud of vapours 2. Release of Toluene from Formation pool and thermal radiation tank due to fire Vapour cloud explosion Dispersion of toxic cloud of vapours 3. Release of Liq. Bromine Vapour cloud explosion from Bottles Dispersion of toxic cloud of vapours 4. Chloroform Toxic cloud of Chloroform 7.6 CONSEQUENCE ANALYSIS Consequence analysis for the selected accident scenarios has been carried to estimate the vulnerable zones. Thermal radiation distances have been computed based on various heat flux values vulnerable to men and materials at the plant while modeling of dispersion cloud is based on IDLH (Immediately Dangerous for Life and Health) values. On identification of vulnerable zones for failure cases, measures can be taken for risk mitigation and to eliminate or minimize damage to the plant and injury to personal Hazards associated with Flammable Chemicals Pool fire: The released flammable material which is a liquid stored below its normal boiling point will collect in a pool. The geometry of the pool will be dictated by the surroundings. If the liquid is stored under pressure above its normal boiling point, then a fraction of the liquid will flash into vapor and the remaining portion will form a pool in the vicinity of the release point. Once sustained combustion is achieved, liquid fires quickly reach steady state burning. The heat release rate is a function of the liquid surface area exposed to air. An unconfined spill will tend to have thin fuel depth (typically less than 5 mm) which will result in slower burning rates. A EIA report of PAB Organics Pvt. Ltd. 7-7

8 confined spill is limited by the boundaries (e.g. a dyke area) and the depth of the resulting pool is greater than that for an unconfined spill. Flash Fire: It occurs when a vapor cloud of flammable material burns. The cloud is typically ignited on the edge and burns towards the release point. The duration of flash fire is very short (seconds), but it may continue as jet fire if the release continues. The overpressures generated by the combustion are not considered significant in terms of damage potential to persons, equipment or structures. The major hazard from flash fire is direct flame impingement. Typically, the burn zone is defined as the area the vapor cloud covers out to half of the LFL. This definition provides a conservative estimate, allowing for fluctuations in modeling. Even where the concentration may be above the UFL, turbulent induced combustion mixes the material with air and results in flash fire. Jet Fire: Jet flames are characterized as high-pressure release of gas from limited openings (e.g. due to small leak in a vessel or broken drain valve). Boiling liquid expanding vapor explosion (BLEVE) or fireball: A fireball is an intense spherical fire resulting from a sudden release of pressurized liquid or gas that is immediately ignited. The best known cause of a fireball is a boiling liquid expanding vapor explosion (BLEVE). Fireball duration is typically 5 20 seconds. Vapor Cloud Explosion: When a large quantity of flammable vapor or gas is released, mixes with air to produce sufficient mass in the flammable range and is ignited, the result is a vapor cloud explosion (VCE). Without sufficient air mixing, a diffusion-controlled fireball may result without significant overpressures developing. The speed of flame propagation must accelerate as the vapor cloud burns. Without this acceleration, only a flash fire will result. Damage Criteria: Damage estimates due to thermal radiations and overpressure have been arrived at by taking in to consideration the published literature on the subject. The consequences can then be visualized by the superimposing the damage effects zones on the proposed plan site and identifying the elements within the project site as well as in EIA report of PAB Organics Pvt. Ltd. 7-8

9 the neighboring environment, which might be adversely affected, should one or more hazards materialize in real life. Thermal Damage: The effect of thermal radiation on people is mainly a function of intensity of radiation and exposure time. The effect is expressed in terms of the probability of death and different degrees of burn. The following tables give the effect of various levels of heat flux. Table 7.3: Fatal Radiation Exposure Level Radiation level (kw/m 2 ) Fatality 1% 50% 99% EXPOSURE IN SECONDS Overpressure Damage Table 7.4: Overpressure Damage Criteria Over Pressure Mechanical damage to equipments Bar kpa Annoying noise (137 db if of low frequency Hz) Occasional breaking of large glass windows already under strain Loud noise (143 db). Sonic boom, glass failure Breakage of small windows under strain Typical pressure for glass breakage Safe distance (probability 0.95 of no serious damage below this value); projectile limit; some damage to house ceilings; 10% window glass broken Limited minor structural damage Large and small windows usually shattered, occasional damage to window frames Minor damage to house structures Partial demolition of houses, made uninhabitable Corrugated asbestos shattered, corrugate steel or aluminum panels, fastenings fail followed by buckling; wood panels (standard EIA report of PAB Organics Pvt. Ltd. 7-9

10 housing) fastenings fail, panels blow in Steel frame of clad building slightly distorted Partial collapse of walls and roofs of houses Concrete or cinder block walls, not reinforced shattered Lower limit of serious structural damage % destruction of brickwork of houses Heavy machines (3000 lb) in industrial building suffered little damage; steel frame building distorted and pulled away from foundations Frameless, self framing steel panel building demolished. Rupture of oil tanks Cladding of light industrial building ruptured Wooden utility poles snapped, tall hydraulic press (40,000 lb) in building slightly damaged Nearly complete destruction of houses Loaded, lighter weight (British) train wagons overturned Brick panels, 8-12 in. thick not reinforced, fail by shearing or flexure Loaded train boxcars completely demolished Probable total destruction of buildings, heavy machine tools (7.000 lb) move and badly damaged, very heavy machine tools (12,000 lb) survive Limit of crater lip Release of Methanol from Tank Jet Fire This scenario was visualized by considering leak sizes 50 mm leak in Storage tanks at various heat radiation levels under the different atmospheric stability classes and wind velocities of 2.5 D and 4 F. The computed damage distances for Leak Sizes of 50 mm at heat loads of 37.5 KW/m², 12.5 KW/m² and 4.0 KW/m² are given in below Table. Pool Fire This scenario was visualized by considering leak sizes of 50 mm in Storage tanks at various heat radiation levels under the different atmospheric stability classes and wind velocities of 2.5 D and 4 F. The computed damage distances for Leak Sizes of 50 mm at heat loads of 37.5 KW/m², 12.5 KW/m² and 4.0 KW/m² are given in Table. Flash Fire This scenario was visualized by considering leak sizes of 50 mm in Storage tanks at various heat radiation levels under the different EIA report of PAB Organics Pvt. Ltd. 7-10

11 atmospheric stability classes and wind velocities of 2.5 F and 4 D. The computed damage distances for Leak Sizes of 50 mm are given in Table Vapor Cloud Explosion This scenario was visualized by considering leak sizes of 50 mm in Underground Storage tanks at various heat radiation levels under the different atmospheric stability classes and wind velocities of 2.5 D and 4 F. The computed damage distances for Leak Sizes of 50 mm at overpressure of , and bar are given in Table. Scenario description Weather data Leakage (Methanol Tank) 2.5 m/s D 4.0 m/s F Damage Distance Flash Fire UFL LFL Jet Fire (kw/m 2 ) Not Reached Not Reached 37.5 Not Reached Not Reached Overpressure (bar) Early Pool fire (kw/m 2 ) Late Pool fire (kw/m 2 ) Figure 7.1 Radiation vs distance for pool fire (Methanol) EIA report of PAB Organics Pvt. Ltd. 7-11

12 Figure 7.2 Flash fire envelope (Methanol) Release of Toluene from Tank Jet Fire This scenario was visualized by considering leak sizes 50 mm leak in Storage tanks at various heat radiation levels under the different atmospheric stability classes and wind velocities of 2.5 D and 4 F. The computed damage distances for Leak Sizes of 50 mm at heat loads of 37.5 KW/m², 12.5 KW/m² and 4.0 KW/m² are given in below Table. Pool Fire This scenario was visualized by considering leak sizes of 50 mm in Storage tanks at various heat radiation levels under the different atmospheric stability classes and wind velocities of 2.5 D and 4 F. The computed damage distances for Leak Sizes of 50 mm at heat loads of 37.5 KW/m², 12.5 KW/m² and 4.0 KW/m² are given in Table. Flash Fire This scenario was visualized by considering leak sizes of 50 mm in Storage tanks at various heat radiation levels under the different atmospheric stability classes and wind velocities of 2.5 F and 4 D. The computed damage distances for Leak Sizes of 50 mm are given in Table. Vapor Cloud Explosion This scenario was visualized by considering leak sizes of 50 mm in Underground Storage tanks at various heat radiation EIA report of PAB Organics Pvt. Ltd. 7-12

13 levels under the different atmospheric stability classes and wind velocities of 2.5 D and 4 F. The computed damage distances for Leak Sizes of 50 mm at overpressure of , and bar are given in Table. Scenario description Weather data Leakage (Toluene Tank) 2.5 m/s D 4.0 m/s F Damage Distance Flash Fire UFL LFL Jet Fire (kw/m 2 ) Not Reached Not Reached Overpressure (bar) Early Pool fire (kw/m 2 ) Late Pool fire (kw/m 2 ) Not Reached Not Reached Not Reached Not Reached Figure 7.3 Radiation vs Distance for pool fire (Toluene) EIA report of PAB Organics Pvt. Ltd. 7-13

14 7.6.4 Release of Bromine from bottles San Envirotech Pvt. Ltd., Ahmedabad Outcome: Bromine Bottle failure, Spillage and Toxic Vapours Toxic hazards are mainly due to Bromine gas leakage and their impact can cross the plant boundary (if not controlled in time). The impact due to Bromine (IDLH) may go up to ~ 65 m i.e. it may cross plant area/storage area. Bromine release will have adverse impact outside the plant battery limit and may involve district authorities to contain the damage. Scenario Table 7.5: Hazards Scenario Impact Scenario Impact Zone (m) Material Remarks RM-1 Bromine IDLH ~ 65 Stability Class D Figure 7.4 Figure 7.4: Bromine Bottle failure, Spillage and Toxic Vapours 7.7 RISK MITIGATION MEASURES For risk mitigation/reduction, attempts should be made to either reduce inventories that could get released in the event of loss of containment or failure likelihood s or both as feasible. Risk analysis identifies the major risk contributors, which enables prioritization of the plant that deserve special attention in terms of inspection and maintenance in particular and over all safety management as a whole. EIA report of PAB Organics Pvt. Ltd. 7-14

15 For the risk reduction at the plant, the following salient suggestions and recommendations are made: On site and off site emergency response plan should be prepared and circulated to concern persons. Personnel at the proposed plant and public in surrounding area should be made aware about the hazardous substance stored at the plant and risk associated with them. A written process safety information document should be compiled for general use. The document compilation should include an assessment of the hazards presented including (i) toxicity information (ii) permissible exposure limits. (iii) Physical data (iv) thermal and chemical stability data (v) reactivity data (vi) corrosivity data (vii) information on process and mechanical design. The process design information in the process safety information compilation must include P&IDs/PFDs; process chemistry; maximum intended inventory; acceptable upper and lower limits, pressures, flows and compositions and process design and energy balances. The adequate numbers of heat and smoke detectors should be provided at strategic locations in the plant and indication of detectors/sensors should be provided in main control room. Predictive and preventive maintenance schedule should be prepared for equipment, piping, etc. and thickness survey should be done periodically as per standard practices. A written procedure (Management of Change) must be developed to manage changes to process chemicals, technology, equipment and procedures that affect a covered process. Safe work practices should be developed to provide for the control of hazards during operation and maintenance such as: i. lockout /tag out ii. Confined space entry ii. Opening process equipment or piping iii. Control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel. EIA report of PAB Organics Pvt. Ltd. 7-15

16 Personnel engaged in handling of hazardous chemicals should be trained to respond in an unlikely event of emergencies. The plant should check and ensure that all instruments provided in the plant are in good condition and documented. Safety measures in the form of safety instruction: should be displayed at strategic locations especially in local language and English. Regular mock drills should be carried out regularly and shortcomings should be recorded and rectified. Records should be maintained for the response of Mock Drills and corrective actions should listed and taken accordingly Personal Protective Equipment Personal protective equipments are devices that are provided to each worker personally for his or her exclusive use. They are intended for temporary use and emergency response action only. If a worker must enter a contaminated area, he must wear adequate protective equipment. Employees should be taught when and how to use respiratory apparatus provided, and how to recognize defects in the equipment. Full dress escape drills should be conducted at least once a year. If such safety equipment is not available, entry into the contaminated area should not be attempted. Keep personal protective equipment where it can be accessed quickly, outside the hazardous material storage area and away from areas of likely contamination. Facial hair should not be permitted for those who are issued escapetype or self-contained respirators because it prevents a proper seal. Each employee should maintain his/her personal protective equipment in clean, working condition at all times. All equipment should be used and maintained in accordance with the manufacturer s instructions Handling of Hazards Personal protective equipment used by the person during handling of hazardous chemicals, should be replaced after certain time. If any spillage of hazardous chemicals, it should be cleaned and disposed as per standard practiced. Empty drums of hazardous chemicals should neutralize immediate. EIA report of PAB Organics Pvt. Ltd. 7-16

17 Personnel engaged in handling of hazardous chemicals should be made aware of properties of hazardous chemicals General Working Conditions (a) House Keeping All the passages, floors and stairways should be maintained in good condition. The system should be available to deal with any spillage of dry or liquid chemical at the plant. Sufficient disposable bins should be clearly marked and these should be suitably located in the plant. In the plant, precaution and instructions should be displayed at strategic locations. All pits, sumps should be properly covered or securely fenced. Roads/walkway within the plant should be maintained neat and clean. (b) Ventilation Adequate ventilation should be provided in the work floor environment. The work environment should be assessed and monitored regularly. Local ventilation is most effective method for controlling dust and gaseous emissions at work floor Safe Operating Procedures Safe operating procedures should be available for mostly all operations and equipment. The workers should be informed of the consequences of failure to observe the safe operating procedures Work Permit System Work permit system should be followed at the plant. Work permit should be used for hot work, Confined space, electrical works, etc Fire Protection Adequate fire fighting facilities should be available at the plant, including, dry chemical type, ABC type, mechanical foam type, CO 2 type and sand buckets. The fire fighting system and equipment should be tested and maintained as per relevant standards. EIA report of PAB Organics Pvt. Ltd. 7-17

18 The fire drills should be conducted once in six months Emergency Preparedness On-site emergency plan should be prepared and readily available for an unlikely event of emergency. Emergency telephone numbers should be available and display properly strategic locations Static Electricity All equipment and storage tanks/containers of flammable chemicals should be bounded and earthed. Electrical resistance for earthing circuits should be maintained. Periodic inspections should be done for earth pit and record should be maintained Material Handling Material handling areas should be clearly defined. The workers should be made aware about the hazards associated with manual material handling Communication System Adequate communication facilities should be available at the plant and supported with uninterrupted power supply. Communication facilities should be checked periodically for its proper functioning Accident Reporting, Investigation and Analysis A system should be initiated for accident and near miss reporting, investigation and analysis. To motivate and awareness among the personnel at the plant about safety, total accident (lost time injury) free days can be displayed on the board prominently at strategic location Safety Inspections The system should be initiated for checklist based routine safety inspection and internal audit of the plant periodically. Safety inspection team should be formed from various disciplines and departments Safe Operating Procedures Safe operating procedures should be formulated and updated, specific to process & equipment and distributed to concerned plant personnel. EIA report of PAB Organics Pvt. Ltd. 7-18

19 7.8 FIRE PROTECTION MEASURES Unit has following facilities to meet any fire in plant premises. Location: Plnat-1A Sr. Fire Extinguisher 1 P-1A 01 2 P-1A 02 3 P-1A 03 4 P-1A 04 5 P-1A 05 6 P-1A 06 7 P-1A 07 8 P-1A 08 9 P-1A P-1A P-1A P-1A P-1A P-1A P-1A P-1A P-1A P-1A 18 Type Capacity Location List Filling Carried Out On Next Filling Due On CO Kgs Inside panel room Mechanical ABC Dry ABC Dry Mechanical ABC Dry Mechanical ABC Dry ABC Dry Mechanical ABC Dry ABC Dry Mechanical Mechanical ABC Dry Mechanical Mechanical Mechanical 50.0 Ltr. Ground floor near plant entrance 25.0 Ground floor near Kgs. plant entrance 5.0 Kgs. Near entrance of dryer area Ltr. Near entrance of dryer area Near entrance of Kgs. dryer area Ltr. Near entrance of dryer area Ground floor back Kgs. side entrance 25.0 First floor near Kgs. plant quarantine 50.0 First floor near Ltr. plant quarantine 25.0 First floor near in Kgs. process store 10.0 First floor near Kgs. entrance of B Ltr. First floor near entrance of B Ltr. First floor near entrance of B First floor near Kgs. entrance of Plant- 1B 50.0 Ground floor near Ltr. entrance Plant-1A 9.0 Ltr. First floor Outside structure Plant-1A 9.0 Ltr. First floor Outside structure Plant-1A Sr. Location: Plnat-1B Fire Extinguisher Type Capacity Location List Filling Carried Out On CO Kg Inside Panel room Plant-1B. Mechanical 25.0 Kgs. Ground floor near plant entrance ABC Dry 5.0 Kgs. Ground floor back side door Mechanical Next Filling Due On 1 P-1B 01 2 P-1B 02 3 P-1B 03 4 P-1B 9.0 Ltr. First floor Ladder 04 5 P-1B ABC Dry 9.0 Kgs. First Floor HVN EIA report of PAB Organics Pvt. Ltd. 7-19

20 05 Plant 6 P-1B 06 ABC Dry 10.0 Kgs. Ground floor HVN Plant 7 P-1B ABC Dry 5.0 Kgs. Ground floor HVN 07 Plant Location: Plant-2 Sr. Fire Extinguisher 1 P P P P P P P P P P P P P P P P P P Location: QC Type Capacity Location List Filling Carried Out On Mechanical 50.0 Ltr. Ground floor near plant entrance Mechanical 9.0 Ltr. Ground floor near plant entrance ABC Dry 25.0 Kgs. Ground floor back side door ABC Dry 5.0 Kgs. Ground floor back side door ABC Dry 10.0 Kgs. First floor near plant ladder Mechanical 50.0 Ltr. First floor near plant entrance ABC Dry 25.0 Kgs. First floor near plant entrance ABC Dry 10.0 Kgs. First floor near plant entrance ABC Dry 5.0 Kgs. First floor near change room ABC Dry 9.0 Ltr. First floor near plant ladder Mechanical 9.0 Ltr. Second floor near plant ladder ABC Dry Mechanical 9.0 Ltr. Second floor near plant entrance ABC Dry 25.0 Kgs. Second floor near plant entrance Mechanical 50.0 Ltr. Second floor near plant entrance ABC Dry 10.0 Kgs. Second floor near plant ladder CO 2 (Carbon Dioxide) Mechanical Next Filling Due On 10.0 Kgs. Second floor plant 4.5 Kgs Inside panel room 50.0 Ltr. Second floor near plant entrance Sr. Fire Extinguisher 1 QC QC Location: Security Office Type Capacity Location List Filling Carried Out On ABC Dry 10.0 Kgs. Outside QC Wet Lab. Mechanical 50.0 Ltr. Outside QC Wet Lab. Next Filling Due On Sr. Fire Extinguisher Type Capacity Location List Filling Carried Out On Next Filling Due On EIA report of PAB Organics Pvt. Ltd. 7-20

21 1 2 SEC SEC Mechanical ABC Dry 9.0 Ltr. Security entrance 50.0 Kgs. Security entrance Location: Store (Ware house) Sr. Fire Extinguisher 1 Store 01 2 Store 02 3 Store 03 4 Store 04 5 Store 05 6 Store 06 7 Store 07 Type Capacity Location List Filling Carried Out On Mechanical ABC Dry ABC Dry 5.0 Kgs. Packing material area ABC Dry Mechanical ABC Dry 10.0 Kgs. Opp. Methanol Store Mechanical Next Filling Due On 9.0 Ltr. Store office Inside 5.0 Kgs. Finish Product area 5.0 Kgs. Raw material store 9.0 Ltr. Raw material store 50.0 Ltr. Outside store office. Location: Office Building Sr. Fire Extinguisher 1 Office 01 2 Office 02 Type Capacity Location List Filling Carried Out On ABC Dry ABC Dry Next Filling Due On 5.0 Kgs. Main Entrance 5.0 Kgs. Near Entrance R&D Lab. Location: Electric Panel Room Sr. Fire Extinguisher 1 EP 01 2 EP 02 Type Capacity Location List Filling Carried Out On CO Kg Inside main Panel room EP 01 CO Ltr. Outside main Panel room EP 02 Next Filling Due On CO 2 CO 2 Location: R & D Lab Sr. Fire Extinguisher 1 R&D 01 Type Capacity Location List Filling Carried Out On ABC Dry Next Filling Due On 5.0 Kgs. R & D Lab. List of Fire hydrant System Sr. Fire Hydrant Hose reels Pipe length/ Diameter meter/ 0.75 inch meter/ 0.75 inch Water Pressure Auto start pressure Water storage capacity Location 5-6 KL 6 Kg/cm 2 15 KL Plant-1A 5-6 KL 6 Kg/cm 2 15 KL Plant-II EIA report of PAB Organics Pvt. Ltd. 7-21

22 7.9 ON-SITE EMERGENCY PLAN The Onsite Emergency Plan describes planning, preparation and training for on-site action in the event of emergency. Preparedness of On Site Emergency Plan For On-Site Emergency Plan Advance planning and proper training of each employee s into the emergency function is very essential to make emergency control measure more effective. It is not possible to eliminate emergency but is definitely possible to control them. The scope of onsite emergency plan is to prepare for activate the emergency time activities, to controlled and contained within the shortest time if emergency arise after failure of our pre-emergency control measures. Following stage activities are consider for the purpose, as they are co-related and provide better points for emergency preparedness Emergency Time Activities It is not possible to include and discuss every action, which should be taken first during emergency. It is also not possible to describe entire actions on emergency situation. The basic principle of handling emergency, that may be relied upon, who have the knowledge and experience to assess the situation and give direction as per the objectives as quickly as possible. Sometimes, it is a natural gift and it is an art by heart. However, the aim is to control the situation by safest way in a limited time within existing available resources. Further, it should be handle with such a care that minimum loss of life, property and environment. In short, the objective of the plan should be successfully complied with Sequential actions during emergency Incident There are possibilities of occurrences of various types of the accidents or mishaps in the factory premises or around the factory. Most of the occurrences will be of minor nature, while few occurrences may be of major type. If the factory is fortunate enough, there may not be a single incident or mishap during its lifespan. However, when any incident occurs, it cannot be distinguished immediately whether it is minor or EIA report of PAB Organics Pvt. Ltd. 7-22

23 major, the subsequent development, or gravity of situation, or seriousness of such occurrence is required safe handling irrespective of its nature, if it cannot be controlled. It should be general practice that whenever any person notices the accident/fire/explosion/mishap at the site, he should immediately shout FIRE, FIRE or HELP, HELP and such message should reach to the Supervisor/Shift Officer/Senior Person of the unit Responding Actions The root cause of occurrence should be removed immediately if possible. Similarly, if any incident takes place in the premises, using available resources, within the factory as well as nearby, to their optimum, it should be so responded that the incident is contained immediately before spreading. If the incident looks severe and could not be controlled by simple efforts, the Shift Officer or Senior Personnel should rush to the place and make every effort to control the incident using various resources at the site. Further, if the incident is uncontrollable even using own resources, he should immediately call for additional helps form outside resources such as Mutual Aiders, Fire Brigade, etc. He should act the Incident Controller and immediately start the following actions: Sound the siren or ring the emergency bell. Take continuous responding actions with the use of other helps. Call the higher authorities and Site Main Controller. Site Crisis On arrival, the Site Main Controller (Factory Manager) will take the charge of Incident site. He will immediately assess the situation and mange the Situation as site crisis. The incident can be said as on-siteemergency. Activate the emergency teams like fire team, first aid team, communication. Team, rescue team, essential workers, key personnel, etc. The Emergency control room will communicate the messages regarding. EIA report of PAB Organics Pvt. Ltd. 7-23

24 Prevailing situation to requisite authorities, outside resources, agencies, neighbors, etc. Non-essential person will rush to safe shelter and roll call will be taken. He will order to shut down the plant, if situation so warrants. Try to contain the situation using all available resources within his command. Now, if the situation is uncontrollable by the management of the unit, he will immediately call for the local crisis group to handle the situation Messages While conveying the messages regarding the incident, the following details should be incorporated. Brief description of incident Type of help required & direction Chemical involved & Quantity Action immediately taken Development of the incident Discipline The plan assuming certain discipline at site during emergency, as follows; Do not get panicky. Do not approach the site of incident as a spectator. Do not engage telephone unnecessary. Do not move about unnecessary. Do not approach unnecessarily for information or more inquiry. Arrange medical first aid care to the injured. Do not allow unnecessary crowd nearby incident Emergency Actions On receiving information, the Emergency Control Centre will activate and urgently establish the contact with the required persons, agencies and authorities. The essential workers, responsible to carry out certain specific functions, will have to start work immediately. EIA report of PAB Organics Pvt. Ltd. 7-24

25 The non-essential workers should go to the assembly center. The cordoning the incident area will be ensured. The water should be sprayed on the flammable storage tank, even if not caught under fire. The experts for the responding to emergency situation will be consulted, if required. vii. Authentic information for incident will be provided to Press/Public by the authorized officer only. Removal the flammable, dangerous material, cylinders, etc. should be arranged along with isolation from fire. The trapped personnel, if any, in incident will be rescued. All assistance will be provided to the Fire Brigade to control spreading of fire. Any remotest possibility of re-ignition or explosion should be looked into and controlled Shut down Procedure It is advisable to shut down the plant for safety, if situation so warrants. The safe shut down procedure should be adopted during such eventualities. First of all, main electrical supply should be cut-off/switchoff. Similarly, the pipelines supplying flammable gas, liquid or chemicals should be immediately shut-off by valves and should be isolated from the process line. The water shower on flammable storage tank, if installed, to be started to keep it in cool condition, if tank is in vicinity of fire. The shut down procedure should be laid down in the process manual, which will be useful during such emergency Post Emergency Activities Post emergency activities comprise of step taken after the emergency is over. To Find out the reason of emergency after the investigation and suggest the preventive measure. For the investigation different level personnel from different dept, are selected and an investigation team is formed. The following steps are taken after the emergency is over. Collection of record Conducting the investigation/inquiry committee with the suggestion for preventive measure EIA report of PAB Organics Pvt. Ltd. 7-25

26 Making the insurance claim and necessary procedure Implementation of the recommendation of inquiry reports Rehabilitation of the affected persons within the plant and outside the plant. They are in continuous touch with the hospitalized person and give status report of them to the top management. Restart the plant if shut down happened Training, Rehearsal and Records Need of Training & Rehearsal Extensive experience in the chemical industry with on-site emergency planning has proved the need and value of rehearsal of emergency procedures. When finalized, the major emergency procedure should be set down in clear, concise terms and everyone on-site made aware of them, particularly the key personnel and essential workers. They should then be put to the test. This may best be done by arranging a series of preliminary exercises to test certain system, including the alternative arrangements in cases of failure. The speed of Mobilization of the factory emergency teams, search & rescue and treatment of casualties, emergency isolation and shut down procedures. These exercises will help to define the procedures by identifying deficiencies and difficulties. At this stage, more exercises that are elaborate can be planned to involve the outside services who should be closely involved at the planning stage. Each exercise should at various positions, e.g. At the scene, the emergency control center, work entrance; assemble points or casualty reception area. A following round-the-table discussion between managers, senior officers of the emergency services, factory inspectorate and observers will further assist to develop practical and effective procedures. It is recommended that a major emergency exercises should be conducted at regular intervals with arrangement with the outside agencies. There is much practical advantage to be gained in situations where people required working together in handling emergencies are already known to each other. Close local liaison and combined exercises are EIA report of PAB Organics Pvt. Ltd. 7-26

27 invaluable in this respect. At the same time, familiarization visits to works especially of the fire service personnel, will help enormously to acquaint with the works layout and the nature of potential hazards. Emergency plans need to be tested when first devised and thereafter to be rehearsed at suitable intervals. Their normal training and experience in day-to-day operation will generally qualify individual personnel with duties under the plans. Some duties, however, such as fire fighting for the works fire team are not routine and special training will be needed. In addition, key personnel will need training in their emergency roles both individually and as a team. For the professional emergency services the general training may be taken for granted. Rehearsals or exercises are important for all personnel likely to be involved in an incident on or off-site because, for example:- They familiarize on-site personnel with their roles, equipment and the details of the plans. They allow the professional emergency services to test their parts of the plan and the co-ordination of all the different organizations. They also familiarize them with the special hazards. They prove the current accuracy of the details of the plan [phone no., etc.] and the availability of special equipment. They give experience and build confidence in the team members. In the initial shock and confusion of a real incident, ability to fall back on established initial actions is invaluable. Employers should ensure that the on-site emergency procedures for such process plants, storage facility, etc. are tested regularly and that all employees receive initial and refresher training. Exercises should be arranged to test each part of the emergency plan on each plant, state by state, starting with first immediate action. Emergency isolation and shut down should be rehearsed from the emergency services, the emergency planning officer [EPO] should be invited to attend on-site exercise, and familiarization visits should be encouraged. The complete plan for each site including both on-site and off-site components should be tested. Many organizations now use tabletop exercises to test emergency plans. EIA report of PAB Organics Pvt. Ltd. 7-27

28 These are very cost effective because they do not interrupt the day-today running of the plant and because many events can be catered for in one session. However, they are theoretical in nature and should be communications and key personnel working from the locations they would use in an emergency. It is, of course, essential that the exercises be carefully prepared, the results analyzed and the lessons learned, circulated and discussed. Full-scale practices involving all concerned that all reasonably practicable measures have been taken. After each rehearsal of practice, the plan should be reviewed to take account of any shortcomings highlighted by the exercise. In addition, its effectiveness should be reviewed every time it is used to with a real emergency. Fix your periodicity to carry out table tope exercises and real rehearsal of this on-site and off-site emergency plan, including mutual aid agencies and mention here in this chapter OFF-SITE EMERGENCY PLAN Need of Off-Site Emergency Plan A major accident, major emergency and disaster may affect areas outside the works. Explosions can scatter debris over wide areas, the effects of blast can cover considerable distances wild can spread burning brands of toxic gases. In some cases, e.g., as the result of an explosion, outside damage will be immediate and part of the available resources of the Emergency Services may need to be developed in the affected area. In any event, the possibility of further damage any remain, e.g., as the result of further explosion or by the effect of wind spreading burning brands of hazardous materials. Perhaps the most significant risk to outside areas is that associated with a large release of toxic vapors. Management will usually need expert advice in drawing up plans so that if such a release occurs, they will be able to collaborate with Emergency services to estimate as far as practicable which downwind areas are at the risk. It may be necessary to prepare in advance simple charts or tables relating the likely spread of the vapor cloud taking into account its expected buoyancy, the local topography and all possible conditions during the time of release. It may also be desirable to install instruments EIA report of PAB Organics Pvt. Ltd. 7-28

29 indicating wind speed and direction. Advice on all these matters can be obtained from the Meteorological office. The fact of the major emergency and the spread or potential spread of its effects outside the work may require that road and rail traffic past the works has to be halted or diverted. The police, taking account of the advice of the Site Main Controller. They will also, where necessary, inform the Rail. The problem is usually exacerbated by members of the public driving to the scene to view the situation. The net effect can be cause problems to those who have a real need to get to the works, including the key personnel who will have been called out. Liaison at local level will help to devise a means whereby key personnel can readily identify themselves to the police controllers. The use of a windscreen sticker of other identify label may be advantageous. All emergency plans should consider the possible effects of incidents on the neighboring population and the remedial measures should be devised in consultation with the local authority and emergency services. The offsite emergency plan should be based on those events identified by the manufacturer, which could affect people and the environment outside his premises. The manufacturer should provide the necessary information on the nature, extent and likely effects of such incidents. The plan should cater in detail for those events identified as being the most likely but should be sufficiently flexible to allow the remedial measures to be able to be extended and increased to deal with extremely adverse combinations of circumstances and consequences. The factory inspectorate and the local authority should be satisfied that the information provided is sufficiently detailed unambiguous and clearly stated to be comprehensible and for the dangers to be provided. Several different planned responses may be necessary at a single site depending on the size and characteristics of the incidents. Thus in brief the two main purposes of the off-site emergency plant are: To provide the local/district authorities, police, fire brigade, doctors, surrounding industries and the public the basic information of risk and environmental impact assessment and to appraise them of the EIA report of PAB Organics Pvt. Ltd. 7-29

DISASTER MANAGEMENT PLAN

DISASTER MANAGEMENT PLAN CHAPTER-VII DISASTER MANAGEMENT PLAN 7.1 INTRODUCTION 7.1.1 Definition A major emergency in a works is one, which has the potential to cause serious injury or loss of life. It may cause extensive damage

More information

Using Consequence Modeling to Help Make Emergency Decisions

Using Consequence Modeling to Help Make Emergency Decisions Using Consequence Modeling to Help Make Emergency Decisions Della Wong / Nova Chemicals & Robert B. Gerow / SAFER-ERMC CSChE 2002 Conference October 20-23, 23, 2002 Vancouver B.C. If auto safety was like

More information

Annexure 2: Rapid Risk Assesment RISK ANALYSIS

Annexure 2: Rapid Risk Assesment RISK ANALYSIS RISK ANALYSIS (I) Catastrophic Rupture of LPG Bullet Truck (18 MT) At the LPG bottling plant, LPG will be transported by Bullet Truck tank. In the event of fire in LPG bullet truck in parking area, BLEVE

More information

RISK ASSESSMENT & DISASTER MANAGEMENT PLAN

RISK ASSESSMENT & DISASTER MANAGEMENT PLAN PAGE - 1 RISK ASSESSMENT & DISASTER MANAGEMENT PLAN 1.1 RISK ASSESSMENT A major accident in an industry has the potential to cause serious injury or loss of life and extensive damage to environment or

More information

Risk Analysis- Sulfuric Acid

Risk Analysis- Sulfuric Acid Sulfonation of LAB with 98% Sulfuric Acid Risk Analysis- Sulfuric Acid Being exothermic reaction, Sulfonation reaction has the potential hazard of causing serious accident. Detailed systematic HAZOP study

More information

QUANTITATIVE RISK ASSESSMENT (QRA) REPORT

QUANTITATIVE RISK ASSESSMENT (QRA) REPORT Report No.:- GCI/V/RMS/2017-18/BG/QRA/R00/1097 QUANTITATIVE RISK ASSESSMENT (QRA) REPORT Prepared For M/s. VADIVARHE SPECIALITY CHEMICALS LTD. Gat No. 204, Nashik-Mumbai Highway, Vadivarhe, Taluka: Igatpuri,

More information

MAXIMUM CREDIBLE LOSS SCENARIO (MCLS)

MAXIMUM CREDIBLE LOSS SCENARIO (MCLS) 1 MAXIMUM CREDIBLE LOSS SCENARIO (MCLS) CLEAN SCIENCE AND TECHNOLOGY PRIVATE LIMITED PLOT NO. D-26/3, MIDC KURKUMBH, DIST.-PUNE 413 802 AUGUST 2016 PREPARED BY S A CONSUTANT NAVI MUMBAI 2 CONTENT AREAS

More information

1. PRODUCT INFORMATION

1. PRODUCT INFORMATION Page 1 of 6 Date Prepared: January 10, 2004 Supersedes: January 09, 2004 MSDS Number: 6436 1. PRODUCT INFORMATION Product Identifier: Application and Use: Aviation synthetic lubricant Product Description:

More information

Hazard Communication Program. San José State University

Hazard Communication Program. San José State University San José State University One Washington Square San José, California Facilities Development and Operations Department July 11, 2012 Page intentionally left blank SJSU_Hazard Communication Program_2012-0711.docx

More information

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT OVERVIEW ASSESSING THE RISK RELATIONSHIP BETWEEN FIRES AND EXPLOSIONS CLASSIFYING HAZARDOUS AREAS INTO ZONES

More information

Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR

Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR Process Safety Management Of Highly Hazardous Chemicals OSHA 29 CFR 1910.119 PSM - Definition Not all refining hazards are caused by the same factors or involve ve the same degree of potential damage.

More information

Practical Modelling & Hazard Assessment of LPG & LNG Spills

Practical Modelling & Hazard Assessment of LPG & LNG Spills Practical Modelling & Hazard Assessment of LPG & LNG Spills UKELG 3 rd April 2012 Tony Ennis Introduction Refrigerated or pressurised Release scenarios & release rate Vaporisation Gas dispersion Consequences

More information

Introduction to Emergency Response & Contingency Planning

Introduction to Emergency Response & Contingency Planning & Contingency Planning Rationale Why is it important for you to learn this material? Designed for those who may witness a release, this is an introductory course designed to help ensure those who are likely

More information

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY Principles in the Optus Contractor WHS management process CONTRACTOR MANAGEMENT STAGES PRINCIPLES THIS STANDARD REQUISITION Requisition

More information

Responding to Natural Gas Pipeline Emergencies

Responding to Natural Gas Pipeline Emergencies Responding to Natural Gas Pipeline Emergencies Who is Florida Gas Transmission? Florida Gas Transmission operates nearly 5,000-miles of interstate natural gas transmission pipelines, a system that extends

More information

Safety Data Sheet 1818BR

Safety Data Sheet 1818BR Safety Data Sheet 1818BR 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: 4 Glass Cleaner Glass & Surface Cleaner Use only for the purpose

More information

1.1 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN 1.2 DEFINITION

1.1 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN 1.2 DEFINITION 1.1 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN 1.2 DEFINITION A major emergency in a work is one which has the potential to cause serious injury or loss of life. It may cause extensive damage to property

More information

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI

Identification and Screening of Scenarios for LOPA. Ken First Dow Chemical Company Midland, MI Identification and Screening of Scenarios for LOPA Ken First Dow Chemical Company Midland, MI 1 Layers of Protection Analysis (LOPA) LOPA is a semi-quantitative tool for analyzing and assessing risk. The

More information

Concordia College Moorhead, Minn.

Concordia College Moorhead, Minn. Concordia College Moorhead, Minn. Title: Employee Right-to-Know/Hazard Communication Effective: 8-20-97; 6-19-00 ; 8-1-03; 8-6-07 Purpose: Concordia College is firmly committed to providing all its employees

More information

TABLE OF CONTENTS PART 2 - CONFINED SPACES

TABLE OF CONTENTS PART 2 - CONFINED SPACES May 11, 2006 TABLE OF CONTENTS PART 2 - CONFINED SPACES Page DEFINITIONS... 2-1 GENERAL... 2-2 RESPONSIBILITIES... 2-2 HAZARD ASSESSMENT AND WORK PROCEDURES... 2-3 IDENTIFICATION AND ENTRY PERMITS... 2-3

More information

HAZARDOUS INCIDENT SITE SAFETY PLAN

HAZARDOUS INCIDENT SITE SAFETY PLAN HAZARDOUS INCIDENT SITE SAFETY PLAN NOTE: A site-specific Site Safety Plan must be developed and implemented for each site where investigators may potentially be exposed to hazardous substances while conducting

More information

Northeast Biomanufacturing Center and Collaborative. Hazard Communication Program (HCP) NBC-HCP-000

Northeast Biomanufacturing Center and Collaborative. Hazard Communication Program (HCP) NBC-HCP-000 Northeast Biomanufacturing Center and Collaborative Hazard Communication Program (HCP) NBC-HCP-000 Date Issued: 06/27/06 Date Revised: 05/30/07 APPLICIPABLE STANDARD: 29CFR1910.1200 OSHA s Hazard Communication

More information

1/5 ULF SDS Japan(English)GHS:5. First edition : Feb. 7, 2002 Revision date : Mar. 14, 2016 Revision number : 7

1/5 ULF SDS Japan(English)GHS:5. First edition : Feb. 7, 2002 Revision date : Mar. 14, 2016 Revision number : 7 1/5 Safety Data Sheet SOLDERITE First edition : Feb. 7, 2002 Revision date : Mar. 14, 2016 Revision number : 7 1.CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name : SOLDERITE Company Name : TAMURA

More information

Safety Data Sheet 1452SYM

Safety Data Sheet 1452SYM Safety Data Sheet 1452SYM 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Rondo Bowl & Urinal Cleaner Acid Bowl Cleaner Use only for

More information

SAFETY DATA SHEET SECTION 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING LEATHER CLEANING & CONDITIONING CREAM

SAFETY DATA SHEET SECTION 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING LEATHER CLEANING & CONDITIONING CREAM SAFETY DATA SHEET SECTION 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING 1.1. Product identifier PRODUCT NAME: LEATHER CLEANING & CONDITIONING CREAM 1.2. Relevant identified

More information

POTENTIAL HAZARDS OF VARIOUS SUBSTANCES

POTENTIAL HAZARDS OF VARIOUS SUBSTANCES POTENTIAL HAZARDS OF CLASS 1 EXPLOSIVES For those Divisions and Compatibility Groups acceptable for carriage by air, little immediate health hazard. Should any explosives consignment become involved in

More information

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities. 11/13/1995 4 5/20/2013 1 of 10 Authority and Scope Regulation: 29 CFR 1910.146 Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such

More information

Safety Data Sheet 1782SYM

Safety Data Sheet 1782SYM Safety Data Sheet 1782SYM 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Grandioso Lemon Oil Cleaner/Polish/Protectant Use only for

More information

Safety Data Sheet 1797SYM

Safety Data Sheet 1797SYM Safety Data Sheet 1797SYM 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Key Glass & Surface Cleaner RTU Ready To Use Glass Cleaner

More information

Safety Data Sheet 1533BR

Safety Data Sheet 1533BR Safety Data Sheet 1533BR 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Spotter Carpet Cleaner Use only for the purpose on product

More information

Storage and Pre-planning Considerations

Storage and Pre-planning Considerations Participant Guide Module 8 Storage and Pre-planning Considerations Module Objective Upon the completion of this module, participants should be able to develop plans to fight or contain fires at tank farms

More information

Safety Data Sheet LPS300 and LPS301

Safety Data Sheet LPS300 and LPS301 Safety Data Sheet LPS300 and LPS301 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Liquid Pro Scrub 10X Concentrate Performance Enhancing

More information

Identification of hazardous units and storage units based on relative ranking technique, viz. Fire-Explosion and Toxicity Index (FE&TI).

Identification of hazardous units and storage units based on relative ranking technique, viz. Fire-Explosion and Toxicity Index (FE&TI). Risk Assessment Risk analysis involves the identification and assessment of risks the persons involved in the proposed project and the neighboring populations are exposed to, as a result of hazard occurrence.

More information

1461BR Lindell Rd Las Vegas, NV (Customer Service) (800) USA (813) International (Chemtel 24 hrs)

1461BR Lindell Rd Las Vegas, NV (Customer Service) (800) USA (813) International (Chemtel 24 hrs) Safety Data Sheet 1461BR 1 Material and Supplier Identification Product Name: Description: Recommended use of the chemical and restrictions: Turbo DC Disinfectant/Cleaner/Sanitizer Use only for the purpose

More information

NO THAW FREEZER/COOLER CLEANER. Use only for the purpose on the product label.

NO THAW FREEZER/COOLER CLEANER. Use only for the purpose on the product label. SAFETY DATA SHEET NO THAW FREEZER/COOLER CLEANER Section 1. Chemical product and company identification Product name Recommended use and restrictions NO THAW FREEZER/COOLER CLEANER Cleaning product Use

More information

Safety Data Sheet 1421

Safety Data Sheet 1421 Safety Data Sheet 1421 1 Material and Supplier Identification Product Name: Description: Recommended use of the chemical and restrictions: Econopine Pine Cleaner Use only for the purpose on product label.

More information

SYSCO FOAM HAND SANITIZER. Use only for the purpose on the product label.

SYSCO FOAM HAND SANITIZER. Use only for the purpose on the product label. SAFETY DATA SHEET SYSCO FOAM HAND SANITIZER Section. Chemical product and company identification Product name Recommended use and restrictions SYSCO FOAM HAND SANITIZER Hand disinfectant Use only for the

More information

Safety Data Sheet 1432BR

Safety Data Sheet 1432BR Safety Data Sheet 1432BR 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Oxy Citrus All-In-One Concentrated, All-Surface Peroxide Based

More information

Safety Data Sheet 1628SYM

Safety Data Sheet 1628SYM Safety Data Sheet 1628SYM 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Solo Gum & Grease Remover Solvent Based Gum Remover Use only

More information

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK THEME nº44: RESPONSIBLE: Basics Principles of Prevention FOUR PRINCIPLES OF OPERATIONAL CONTROL The general objective in the control of hazards relating to chemicals in the workplace is to eliminate or

More information

Confined Space Entry. My Experience so far.

Confined Space Entry. My Experience so far. Confined Space Entry My Experience so far My Experience so far Complacency to Confined Space working Is the area a Confined Space No company procedures Poor risk assessments A lot of confusion Staff &

More information

Chapter-7 Additional Studies

Chapter-7 Additional Studies San Envirotech Pvt. Ltd., Ahmedabad Chapter-7 Additional Studies Following additional studies have been included in this chapter. Risk assessment Occupational Health Programme On-site/Off-site Emergency

More information

SAFETY DATA SHEET. P.O. Box 4272 CHEMTREC: (800) Houston, TX KRONOS: (800) Customer Service: (800)

SAFETY DATA SHEET. P.O. Box 4272 CHEMTREC: (800) Houston, TX KRONOS: (800) Customer Service: (800) 2. PRODUCT COMPOSITION Product Classification: Chemical Intermediate. Component(s) C.A.S. No. Percent Sulfuric Acid Titanium Dioxide 7664-93-9 13463-67-7 3 29 3. HAZARD IDENTIFICATION Warning: Contact

More information

Safety Data Sheet 1126SYM

Safety Data Sheet 1126SYM Safety Data Sheet 1126SYM 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Loco Oven, Grill & Hood Cleaner Oven and Grill Cleaner Use

More information

Class 2 Gases Learning Tool

Class 2 Gases Learning Tool Class 2 Gases Learning Tool This work has been produced by DGL (Aust) Pty Ltd This Learner s Guide is about the skills and knowledge required to store and warehouse Class 2 Gases at DGL (Aust) facilities.

More information

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET MATERIAL SAFETY DATA SHEET SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT: M-Line Rosin Solvent November 22, 2005 Vishay Micro-Measurements Post Office Box 27777 Raleigh, NC 27611 919-365-3800

More information

Vickers Laboratories Ltd - Safety Data Sheet 1185

Vickers Laboratories Ltd - Safety Data Sheet 1185 Vickers Laboratories Ltd - Safety Data Sheet 1185 (in accordance with regulation 2015/830/EC) Section 1. Identification 1.1 Product Identifier 1185 Product Name LACTIC ACID pure CAS Number 79-33-4 REACH

More information

SAFETY DATA SHEET INTERNATIONAL FLAVORS & FRAGRANCES

SAFETY DATA SHEET INTERNATIONAL FLAVORS & FRAGRANCES Print Date 08/20/2015 Page 1 (8) SECTION 1. PRODUCT AND COMPANY IDENTIFICATION name : IFF Code : 00044940 Cust. Material : 00044940 MSDS Number : R00000219533 Use Description : Flavour or Fragrance Ingredient

More information

1 Purpose. 2 Responsibilities. 3 Policy Content ENVIRONMENTAL, HEALTH AND SAFETY STANDARDS. TITLE: CONFINED SPACE ENTRY Document Number: *

1 Purpose. 2 Responsibilities. 3 Policy Content ENVIRONMENTAL, HEALTH AND SAFETY STANDARDS. TITLE: CONFINED SPACE ENTRY Document Number: * (Insert Company Logo) CORPORATE SAFETY MANUAL ENVIRONMENTAL, HEALTH AND SAFETY STANDARDS TITLE: CONFINED SPACE ENTRY Document Number: * Issue Date: Revision Date: * 1 Purpose The purpose of this policy

More information

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET MATERIAL SAFETY DATA SHEET SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT: M-Bond Curing Agent - Type 15 April 13, 2010 Vishay Measurements Group, Inc. Post Office Box 27777 Raleigh, NC

More information

Material Safety Data Sheet

Material Safety Data Sheet Creation Date: 04-12-2007 Revision Date: 04-12-2007 Material Safety Data Sheet 1 Chemical Product and Company Identification Material Name ULight-IRS-1 (Tyr983) peptide, 1 nmole (1,000 assay points) Version

More information

CONFINED SPACE PROGRAM

CONFINED SPACE PROGRAM CONFINED SPACE PROGRAM A confined space, as defined in 29 CFR 1910.146: Is large enough and so configured that an employee can bodily enter and perform assigned work AND Has limited or restricted means

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 Utilities Gas Emergencies Revised Truck Module Page 1 of 5 GAS EMERGENCIES Introduction Natural gas and Liquid Propane Gas (LPG) are flammable gases. Many households and commercial buildings utilize these gases for everything from heating

More information

SAFETY DATA SHEET. According to Regulation (EU) 2015/830. Solvent Based Cleaner

SAFETY DATA SHEET. According to Regulation (EU) 2015/830. Solvent Based Cleaner SAFETY DATA SHEET According to Regulation (EU) 2015/830 Solvent Based Cleaner SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product name Solvent

More information

Safety Data Sheet 1565BR

Safety Data Sheet 1565BR Safety Data Sheet 1565BR 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Enzyme Cleaner & Deodorizer Cleaner & Deodorizer Use only for

More information

Safety Data Sheet 1921SYM

Safety Data Sheet 1921SYM Safety Data Sheet 1921SYM 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Jazz Foaming Cleaner Degreaser Heavy Duty Cleaner/Degreaser

More information

EXPRESS GEL HAND SANITIZER. Use only for the purpose on the product label.

EXPRESS GEL HAND SANITIZER. Use only for the purpose on the product label. SAFETY DATA SHEET EXPRESS GEL HAND SANITIZER Section 1. Chemical product and company identification Product name Recommended use and restrictions EXPRESS GEL HAND SANITIZER Skin Cleaner Use only for the

More information

Use only for the purpose on the product label. Ecolab Inc. Food & Beverage Division 370 N. Wabasha Street St. Paul, MN

Use only for the purpose on the product label. Ecolab Inc. Food & Beverage Division 370 N. Wabasha Street St. Paul, MN SAFETY DATA SHEET RailCare Lube Shield Section 1. Chemical product and company identification Product name Recommended use and restrictions RailCare Lube Shield Lubricant Use only for the purpose on the

More information

SAFETY DATA SHEET. In accordance with 29 CFR Section 1. Identification of the substance or the mixture and of the supplier

SAFETY DATA SHEET. In accordance with 29 CFR Section 1. Identification of the substance or the mixture and of the supplier Page 1 ( 6 (05/01/2018 Section 1. Identification of the substance or the mixture and of the supplier 1.1 Product Identifier Product identifier: Other identifiers: None 1.2 Relevant identified uses of the

More information

MATERIAL SAFETY DATA SHEET COMPANY: HAYCARB HOLDINGS (AUST) PTY LTD

MATERIAL SAFETY DATA SHEET COMPANY: HAYCARB HOLDINGS (AUST) PTY LTD MATERIAL SAFETY DATA SHEET COMPANY: HAYCARB HOLDINGS (AUST) PTY LTD PRODUCT: ACTIVATED CARBON SECTION 1 IDENTIFICATION OF THE MATERIAL & THE SUPPLIER Haycarb Holdings (Aust) Pty Ltd Emergency Telephone

More information

Hazardous Materials Management Guidelines

Hazardous Materials Management Guidelines Environmental, Health and Safety Guidelines Hazardous Materials Management Guidelines Applicability These guidelines apply to facilities and activities involving the transportation, production, handling,

More information

DIGICLEAN ANTI-BACTERIAL FOAM HAND SOAP. Use only for the purpose on the product label.

DIGICLEAN ANTI-BACTERIAL FOAM HAND SOAP. Use only for the purpose on the product label. SAFETY DATA SHEET DIGICLEAN ANTI-BACTERIAL FOAM HAND SOAP Section 1. Chemical product and company identification Product name Recommended use and restrictions DIGICLEAN ANTI-BACTERIAL FOAM HAND SOAP Skin

More information

Safety Data Sheet 1225BR

Safety Data Sheet 1225BR Safety Data Sheet 1225BR 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: High Gloss Finish Floor Finish Use only for the purpose on

More information

Hazardous Material Emergency Spill Response Protocol WAC

Hazardous Material Emergency Spill Response Protocol WAC Hazardous Material Emergency Spill Response Protocol WAC 296-824 1.0 Policy PLU s highest priority is to protect employee and student health and safety. On that basis, PLU employees or students will not

More information

1.0 Scope and Application. 2.0 Definitions. Cal Poly Risk Management Confined Space Program Page 1

1.0 Scope and Application. 2.0 Definitions. Cal Poly Risk Management Confined Space Program Page 1 Page 1 1.0 Scope and Application The following procedures describe safe operating practices in confined spaces. These may be sewers, pipelines, tanks, boiler compartments, ducts, vaults, pits, vats, bins

More information

Section 1. Identification

Section 1. Identification Section 1. Identification Product Name SULPHUR RESUBLIMED CAS Number 7704-34-9 REACH Registration No 01-2119487295-27-XXXX Molecular Formula S Atomic Wt = 32.06 1.1 Relevent identified uses of the substance

More information

Working in Gas Hazard Areas

Working in Gas Hazard Areas / Health & Safety OPERATIONS STANDARDS Ref.: Aperam Safety ST 012 Working in Gas Hazard Areas Issue: 15.05.2012 Vers.: v0 Rev.: AM Safety ST 012 v1.2 08.05.2012 Working in Gas Hazard Areas Controlled Updated

More information

Rockhampton Office Brisbane Office Tarong Site. Barron Gorge Hydro PS Kareeya Hydro PS Mica Creek PS

Rockhampton Office Brisbane Office Tarong Site. Barron Gorge Hydro PS Kareeya Hydro PS Mica Creek PS Business Procedure Hot Work Document Number OHS-PROC-128 This document applies to the following sites: All Sites Rockhampton Office Brisbane Office Tarong Site Barron Gorge Hydro PS Kareeya Hydro PS Mica

More information

CONFINED SPACE PROGRAM

CONFINED SPACE PROGRAM CONFINED SPACE PROGRAM Last updated: November 2017 1.0 PURPOSE Entry into a confined space represents a significant risk of serious injury or death to individuals not prepared for the hazards they may

More information

Material Safety Data Sheet

Material Safety Data Sheet Creation Date: 10-15-2007 Revision Date: 10-15-2007 Material Safety Data Sheet 1 Chemical Product and Company Identification Material Name Relaxin-3 (h) [125I] Version # 01 CAS # Mixture Item # NEX418010UC

More information

Safety Data Sheet 1454

Safety Data Sheet 1454 Safety Data Sheet 1454 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Citra-Cide Disinfectant/Cleaner/Sanitizer Use only for the purpose

More information

SAFETY DATA SHEET. Section 1: Identification of the substance/mixture and of the company/undertaking. Section 2: Hazards identification

SAFETY DATA SHEET. Section 1: Identification of the substance/mixture and of the company/undertaking. Section 2: Hazards identification Page: 1 Compilation date: 28/04/2009 Revision date: 21/11/2012 Revision No: 2 Section 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product name: CAS

More information

SAFETY AND OSHA GUIDELINE CURRICULUM

SAFETY AND OSHA GUIDELINE CURRICULUM SAFETY AND OSHA GUIDELINE CURRICULUM CertiLearn - Non-Industrial OSHA Safety Guidelines These courses are ideal for any small business or non-industrial environment Safety Basics In this course you will

More information

HAZARDOUS INGREDIENTS. Name of the Ingredient Xylene, mixtures of o--, m- and p- Xylene

HAZARDOUS INGREDIENTS. Name of the Ingredient Xylene, mixtures of o--, m- and p- Xylene MATERIAL SAFETY DATA SHEET (PU THINNER) 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION: Trade Name : POLYURETHANE THINNER Application 2. COMPOSITION AND INFORMATION ON INGREDIENTS: : Expressed in writing

More information

Safe Work Practices / Procedures / Instruction CONFINED SPACE

Safe Work Practices / Procedures / Instruction CONFINED SPACE CONFINED SPACE Entry into and work in a confined space poses health and safety problems which may include: Presence or possible build up of a hazardous atmosphere Unexpected movement of equipment or materials

More information

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET 1. CHEMICAL PRODUCT AND COMPANY INFORMATION Product Name: Lubspar 110 (0290) MATERIAL SAFETY DATA SHEET Manufacturer Information: Tulco Oils, Inc. 5240 E. Pine Street Tulsa, Oklahoma 74115 Product Use:

More information

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET MATERIAL SAFETY DATA SHEET SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT: M-Line Rosin Solvent April 13, 2010 Vishay Measurements Group, Inc. Post Office Box 27777 Raleigh, NC 27611 919-365-3800

More information

Timstar Laboratory Suppliers - Safety Data Sheet

Timstar Laboratory Suppliers - Safety Data Sheet (in accordance with regulation 2015/830/EC) PR5082 Section 1. Identification 1.1 Product Identifier PR5082 Product Name PROPANE-1,2-DIOL pure 500ml. CAS Number 57-55-6 REACH Registration No 01-2119456809-23-XXXX

More information

FACILIPRO WATERLESS FOAM HAND SANITIZER. Use only for the purpose on the product label.

FACILIPRO WATERLESS FOAM HAND SANITIZER. Use only for the purpose on the product label. SAFETY DATA SHEET FACILIPRO WATERLESS FOAM HAND SANITIZER Section 1. Chemical product and company identification Product name Recommended use and restrictions FACILIPRO WATERLESS FOAM HAND SANITIZER Skin

More information

Safety Data Sheet 1626SYM

Safety Data Sheet 1626SYM Safety Data Sheet 1626SYM 1 Material and Supplier Indentification Product Name: Description: Recommended use of the chemical and restrictions: Jazz Citrus Degreaser Cleaner/Degreaser Use only for the purpose

More information

Welding, Cutting, and Brazing

Welding, Cutting, and Brazing Welding, Cutting, and Brazing Hazards of Welding Operations Fire hazards Metal splatter Electric shock Explosion hazards Released gases Radiant energy Where would these hazards be found on oil and gas

More information

! Subpart D - Contingency Plans and Emergency Procedures (40 CFR to ) (EPA regulations adopted by NJDEP); and

! Subpart D - Contingency Plans and Emergency Procedures (40 CFR to ) (EPA regulations adopted by NJDEP); and APPENDIX D EMERGENCY PROCEDURES IN PUBLIC SECONDARY SCHOOLS IN THE EVENT OF A CHEMICAL SPILL There are five major sources of regulations that are potentially applicable to emergencies involving a chemical

More information

BASF Flash Fire FRC Assessment Tool

BASF Flash Fire FRC Assessment Tool BASF Flash Fire FRC Assessment Tool Introduction The assessment tool offered in this document was developed to assist BASF manufacturing units in evaluating the potential for flash fire occurrence and

More information

Section J. How to develop safety elements for project safety management system. How to develop safety elements for project SMS

Section J. How to develop safety elements for project safety management system. How to develop safety elements for project SMS Section J How to develop safety elements for project safety management system 1. Once the project management has developed or adopted a safety policy, it needs to develop safety elements to meet the objectives

More information

ALINCO X LINSEED OIL. House paints, enamels, flat wall finishes,varnishes, printing inks.

ALINCO X LINSEED OIL. House paints, enamels, flat wall finishes,varnishes, printing inks. 1. IDENTIFICATION OF THE MATERIAL AND SUPPLIER Product Name: Other name(s): ALINCO X LINSEED OIL Heat polymerized refined linseed oil; Alinco Y; Linseed heat bodied oil; Linseed stand oil. Recommended

More information

MAKON TSP-16. Level 8, 1 Nicholson Street East Melbourne Victoria 3002 Australia (ALL HOURS)

MAKON TSP-16. Level 8, 1 Nicholson Street East Melbourne Victoria 3002 Australia (ALL HOURS) 1. IDENTIFICATION OF THE MATERIAL AND SUPPLIER Product Name: MAKON TSP-16 Recommended Use of the Chemical and Restrictions on Use Surfactant. For industrial use only. Supplier: Ixom Operations Pty Ltd

More information

Silva Gal- MSDS (January 2008)

Silva Gal- MSDS (January 2008) Silva Gal- MSDS (January 2008) SECTION 1- IDENTIFICATION OF THE MATERIAL AND SUPPLIER 1.1 Product Name Silva Gal Finishes 1.2 Manufacturers product code various 1.3 Uses Industrial Paint (Spraying) 1.4

More information

NORMAL OPERATING PROCEDURES Operating Parameter Information

NORMAL OPERATING PROCEDURES Operating Parameter Information Operating Parameter Information Each operator performing the normal operating procedures (routine checks) of the facility should be familiar with the current normal operating parameters of all systems

More information

7 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN

7 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN 7 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN 7.1 General The scope of the report includes the study of storage, handling and transportation activities of the raw materials of the proposed plant with

More information

Raw material for the chemical-technical industry. Level 8, 1 Nicholson Street Melbourne 3000 Australia (ALL HOURS)

Raw material for the chemical-technical industry. Level 8, 1 Nicholson Street Melbourne 3000 Australia (ALL HOURS) 1. IDENTIFICATION OF THE MATERIAL AND SUPPLIER Recommended Use of the Chemical and Restrictions on Use Raw material for the chemical-technical industry. Supplier: Ixom Operations Pty Ltd ABN: 51 600 546

More information

Activated Carbon %

Activated Carbon % MSDS for Activated Carbon Page 1 of 7 GREEN CARBON, INC. MATERIAL SAFETY DATA SHEET ACTIVATED CARBON Effective Date: 10/03/05 Product: Activated Carbon 1. Product Identification Synonyms: Washed Activated

More information

Use only for the purpose on the product label.

Use only for the purpose on the product label. SAFETY DATA SHEET APEX POT AND PAN SOAK Section 1. Chemical product and company identification Product name Recommended use and restrictions APEX POT AND PAN SOAK Presoak Use only for the purpose on the

More information

MC-780 C-12 Kit. SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006. Version: Print Date

MC-780 C-12 Kit. SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006. Version: Print Date 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING English Product information Commercial Product Name Recommended use: Sealant Company: Chemetall plc Denbigh Road Bletchley

More information

SAFETY DATA SHEET INDUSTRIAL EP COMPOUND HEAVY DUTY GEAR LUBRICANTS Revision Date:

SAFETY DATA SHEET INDUSTRIAL EP COMPOUND HEAVY DUTY GEAR LUBRICANTS Revision Date: SAFETY DATA SHEET INDUSTRIAL EP COMPOUND HEAVY DUTY GEAR LUBRICANTS Revision Date: 06-01-2018 Section 1. Identification Product Identifier Product Name Industrial EP Compound Heavy Duty Gear Lubricants

More information

SAFETY DATA SHEET. Flam. Aerosol 1: H222; -: H229 Extremely flammable aerosol. Pressurised container: May burst if heated.

SAFETY DATA SHEET. Flam. Aerosol 1: H222; -: H229 Extremely flammable aerosol. Pressurised container: May burst if heated. Page: 1 Compilation date: 07/10/2004 Revision date: 23/04/2015 Revision No: 4 Section 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product name: 1.2.

More information

Based on available information, not classified as hazardous according to criteria of Safe Work Australia; NON-HAZARDOUS SUBSTANCE.

Based on available information, not classified as hazardous according to criteria of Safe Work Australia; NON-HAZARDOUS SUBSTANCE. 1. IDENTIFICATION OF THE MATERIAL AND SUPPLIER Product Name: Other name(s): Recommended Use: DISTILLED TOPPED HARDENED COCONUT OIL FATTY ACID (DTHCFA), C12-18 HARD Coconut Fatty Acids Cosmetic applications.

More information

Addendum 4 Levels of Response

Addendum 4 Levels of Response Addendum 4 Levels of Response Levels of Response to a Hazardous Materials Incident A. Criteria for Categorization Hazardous materials incidents are categorized as Level I, II, or III depending on the severity

More information

* HMIS CODE ratings are estimated by Epoxy Technology. II. HAZARDOUS INGREDIENTS CAS# WT % TOXICITY DATA

* HMIS CODE ratings are estimated by Epoxy Technology. II. HAZARDOUS INGREDIENTS CAS# WT % TOXICITY DATA MATERIAL SAFETY DATA SHEET EPOXY TECHNOLOGY 14 FORTUNE DRIVE PRODUCT NAME: EpoTek OG154-1 BILLERICA, MA 01821 Single Component EMERGENCY PHONE: *HMIS: HEALTH- 2 FIRE-1 REACTIVITY- 0 (978) 667 3805 Carcinogen:

More information

EMERGENCY RESPONDER INFORMATION

EMERGENCY RESPONDER INFORMATION EMERGENCY RESPONDER INFORMATION Ammonia is a Toxic Gas When released can come out as liquid and as a vapor cloud at the same time. Vapor cloud can be heavier than air Vapor cloud can be white or invisible

More information

Raw material for the chemical-technical industry. Organic Crop Protectants Pty Ltd Turrella Street TURRELLA NSW 2205 Australia

Raw material for the chemical-technical industry. Organic Crop Protectants Pty Ltd Turrella Street TURRELLA NSW 2205 Australia 1. IDENTIFICATION OF THE MATERIAL AND SUPPLIER Product Name: HYDRASOIL Recommended Use of the Chemical and Restrictions on Use Raw material for the chemical-technical industry. Supplier: ABN: Street Address:

More information