Standard Specifications
|
|
- Terence Hall
- 5 years ago
- Views:
Transcription
1 NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max. operating pressure psig (MPa) Set pressure range psig (MPa) Ambient and fluid temperature Fluid Cracking pressure (Valve) psig (MPa) Construction Port size/weight Porting NARM NARM Regulator for manifold Body size 2 Number of stations station station Air 75 (.2) 2 (.8) 7~ (.5 to.7) 23 ~ F ( 5 to 6 C) (No freezing) Air 3 (.2) Relief style Port size Weight lb (g) IN OUT Total weight (n: stations) Regulator (Except manifold) (8 X n) + 23 (79 X n) + 25 (88 X n) + 3 ( X n) A G Porting Symbol IN OUT A Manifold side Common A2 Body side B Manifold side Individual B2 Body side Note) In case of A and B, a pressure gauge or a plug is mounted at the body side, while in case of A2 and B2, at the manifold side. Note2)Pressure gauges mounted in body are oriented so that the 6 o'clock position of the gauge is at the pressure adjusting screw. Port size (OUT side) 8 Thread N.3 (57).3 (36) Option Set at.2mpa Note) Pressure gauge for MPa is used. Note2) Only the adjusting spring is different from the standard model. Accessory G Rc(PT) NPT None (with plug) Pressure gauge Part Name NARM Regulator w/o mfld NARMA A Pressure gauge G5-P-N G5-P-N Blanking plate kit 36A 362A (plate, screws, and o-ring) Manifold base, 362-*-N 36-*-N (A, A2) Manifold base, 363-*-N 3623-*-N (B, B2) * Denotes number of stations: 2~ available. -A2-NG Symbol IN OUT IN OUT OUT IN OUT Option: Pressure gauge G (5) Precautions:.33 ( (8.5).26 (6.5) M5 x.8 /8.39 () G5 P Units Nil MPa P PSI Max. pressure indication 5PSI (.MPa) *Pressure gauge for psig (.2MPa) is not available. Please use gauge for 5psi (.MPa). Thread N Rc(PT) NPT Kind of connecting thread 8 male thread, M5 female thread
2 NARM, 2 Construction () Specialty Regulators Flow Characteristics NARM Supply pressure: psig Secondary (psig) Component Parts No. Description Body 2 Manifold 3 Valve guide Piston 5 Adjusting spring 6 Adjusting screw Replacement Parts No Setting Warning Caution Warning Description Valve Valve spring Valve retainer Material Brass/ Stainless steel POM Make sure to check the primary pressure before setting the secondary pressure. Turning the pressure adjustment handle clockwise increases the secondary pressure and turning it counterclockwise decreases the pressure. (To set Material ADC Aluminum alloy Brass Brass Steel wire Steel Precautions Mounting/Adjustment Maintenance NARM x 3.5 x.5 P7 Note Chromate Chromate Zinc chromate Electroless nickel plating x 2 x.5 P8 the pressure, do so in the direction of pressure increase.) 2 The secondary pressure must be set to 85% or less of the primary pressure. Be sure to read before handling. Refer to page 6 for Safety Instructions and precuations common to the products mentioned in this volume and refer to pages 7 and 8 for more detailed precautions of every series. In the case of the common IN type, supply pressure from the two IN ports from both ends. Failure to observe this procedure could lead to an excessive pressure drop. 2 Set up the regulator while verifying the pressure that is indicated on the primary and the secondary pressure gauges. Turning the handle excessively could damage the internal parts. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the secondary pressure to fluctuate. Make sure to perform a periodic inspection of the pressure gauge when it is used by installing it between a solenoid valve and an actuator, etc. Because of the possibility of creating sudden pressure fluctuations, the durability of the product could be shortened. Under certain circumstances, the use of an electronic type pressure gauge is recommended Secondary Pressure (psig) Pressure Characteristics Initial setting Supply pressure:.7mpa{7.kgf/cm 2 } Secondary pressure:.2mpa{2.kgf/c Flow:. SCFM Secondary (psig) NARM Secondary (psig)
3 NARM, 2 NARM Symbol A B C D E F G H J K M P Q R (.5) (25) (3) (2) (8) (56) (6) (9) (8) (9) (52) (9) (.5) (.8) (.5) (3.5) (3) (28) (27) (7) (2) (.5) (2) (28) (66) (.5) (6.5) (.8) by number of stations Symbol A C E F G H J K M P NARM L (36) (55) (7) (93) (2) (3) (5) (69) (88) (27) (27) (6) (65) (8) (3) () () (6) (79) (98) L (8) (76) () (32) (6) (88) (26) (2) (272) () (39) (67) (95) (23) (5) (79) (27) (235) (263) (29) 3
4 , Specialty Regulators A modular type that can easily be mounted in a manifold station. Optimal for central pressure control. Pressure easily set using the new handle. One-touch lock system. NARM 25 5 A Regulator for manifold Body size 25 Number of stations 2 2 stations stations 2 G Piping Symbol Type A B Accessory None (with plug) G KA-MP.-NM G2 KA-MP.-NM Port size (OUT side) Symbol Port size Applicable model 2 NPT / 3 NPT 3/8 IN From end plate Below: OUT port or G port Standard Specifications Proof pressure psig (MPa) Max. operating pressure psig (MPa) Set pressure range psig (MPa) Ambient and fluid temperature Fluid Construction (.5) 5 (.) 7~2 (.5 to.85) 23~ ( 5 to 6 C) (No freezing) Air Relief type Port size/weight Symbol Piping Body Port size NPT IN OUT End plate 2 Pressure gauge port size NPT Weight lb (kg) Regulator.57 (.26). (.7) End plate.3 (.6).2 (.) Weight by number of stations Stations (.68) 2.67 (.25) 2.2 (.96) 3.86 (.75) 2.7 (.23).96 (2.25) 3.33 (.5) 6.6 (2.75) 3.92 (.78) 7.9 (3.26).5 (2.6) 8.29 (3.76) 5. (2.33) 9.39 (.26) 5.75 (2.6).9 (.76) lb (kg) 6.37 (2.89).6 (5.26)
5 Option: Mounting bolt ass'y Hexagon socket head cap screw (M5 x 7) Hexagon socket head cap screw (M6 x 85) Option: Bracket assembly type can be used as a single regulator. Qty. Note With flat washer With flat washer Secondary Pressure (psig) Flow Characteristics Supply pressure: psig A ().6 () Warning Caution B.3 (3).57 () C D E F G 2.76 (7) 2.97 (75.5).2 (5.).26 (6.5) Precautions.6 (5.).3 (8) 2.7 (55) 2.9 (53).9 (2.3).9 (2.3) Be sure to read before handling. Refer to page 6 for Safety Instructions and precuations common to the products mentioned in this volume and refer to pages 7 and 8 for more detailed precautions of every series. The adjustment handle must be operated manually. Using a tool to turn the handle could lead to damage. Set up the regulator while verifying the pressure that is indicated on the primary and the secondary pressure gauges. Turning the handle excessively could damage the internal parts. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the secondary pressure to fluctuate. ) On the, pull the adjustment handle to release the lock and push the adjustment handle to engage the lock. If it does not lock easily, turn the handle slightly clockwise or counterclockwise before pushing it. Mounting/Adjustment 2 3 2) On the, pull the adjustment handle to release the lock. (An orange colored line is provided at the bottom of the adjustment handle for visual checking.) Push the adjustment handle to engage the lock. If it does not lock easily, turn the handle slightly clockwise or counterclockwise; then, push it until the orange colored line is no longer visible. Turning the pressure adjustment handle clockwise increases the secondary pressure and turning it counterclockwise decreases the pressure. Make sure to check the primary pressure before setting the pressure. The secondary pressure must be set to 85% or less of the primary pressure. Failure to observe this procedure could cause the secondary pressure to fluctuate. In the case of the common IN type, supply pressure from the two IN ports from both ends. Failure to observe this procedure could lead to an excessive pressure drop. Secondary Pressure (psig) Pressure Characteristics Secondary pressure (psig) Supply pressure psig Secondary pressure psig Flow rate.7 SCFM Secondary pressure (psig)
6 , Specialty Regulators Construction 6 Main Parts No. Description Material Note Body Aluminum die casting Chromate/Platinum silver painting 2 Bonnet Polyacetal Component Parts No. Description Material Diaphragm ass'y Valve ass'y Valve spring Brass/ Stainless steel 396A 3639A A 369A 36 Valve.5 X 8.5 X.5.5 X.5 X 2 P3 28 X 25 X.5 P5 35 X 3 X 2 Component Parts Assembly Description No. Component Qty. Regulator 9 Regulator End plate R End plate L End 2 plate 3636A 3636B 366A 366B Bracket A 2 ass'y (Except for ) (Except for ) 3 Bracket B 2 Hexagon socket set head cap screw 2 Bracket Bracket A ass'y Bracket B 5 2 Hexagon socket set head cap screw 2 25 A () When adding n stations to ARM - B: Regulator n pcs. Bracket ass'y n pcs. (2) When ordering regulators, end plate assembly and bracket assembly are assembled to make the manifold of n stations. Regulator n pcs. Bracket ass'y n pcs. End plate ass'y pc. Bracket Bracket -A-N2 -B-N2 -A-N3 -B-N3
7 , øp by number of stations Symbol Symbol A B C D E F G H I J K L M N O P (6) (7) () (56) (2) (26.5) () (5) (7) (2) (38) (2) (29) (8) (68) (33.5) (7) (2) (5) (968) (55) (53.5) (7) (53) (23.5) (27.5) (8.5) (55) (35) (59) (85.5) (2.5) L (8) (6) () (2) (286) (328) (37) (2) (5) (6) (8) (9) (232) (27) (36) (3) () (2) L (8) (26) (68) (2) (252) (29) (336) (378) (2) L (52) (27) (262) (37) (372) (27) (82) (537) (592) (38) (93) (28) (3) (3) (3) (68) (523) (578) L () (65) () (275) (3) (385) () (95) (55) 7
Direct Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationRegulator/Modular Style AR1000 to 6000
Regulator/Modular Style AR000 to 6000 Can be combined with a modular style air filter and lubricator A rich variety of models enables precise and stable pressure settings to meet user needs Drain cock
More informationFlow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (
How To Order NAR 1, 2, 25,, 4, 5, 6 Regulator Body size 1 M5 2 1/8 25 1/4 3/8 4 1/2 5 3/4 6 1 NAR N 3 BG 1N Port Thread Nil Rc(PT) F G(PF) N NPT Accessories and Combinations Accessory Suffix 1 4 N R Port
More informationModular Type Regulators
Modular Type Regulators Series AR AC Regulator Series AR Port size Options AFARAL, 1/4 Bracket AFAR AWAL AR4-A, 1/2 Round type pressure gauge With set nut (for panel mount) AFAFMAR P.45 to 5 AR4-6-A ot
More informationRegulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2
Regulator: Modular Type with ack flow Mechanism R3 to 6 How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure (built-in check valve with back flow mechanism).
More informationRegulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK
More informationRegulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,
More informationCompact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ
Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face
More informationPower Valve: Precision Regulator. High precision, large capacity relief regulator
Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationStandard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range
Manifold Regulator Series ARM000/000 connection methods Standard Specifications Fluid Proof pressure Maximum operating pressure Regulating pressure range Ambient and fluid temperature Fluid Cracking pressure
More informationAir Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.
Air Saving Valve Series R Pressure Valve Series Q Flow Valve P r.9.7 2..3.1 D -FE KE -FG -FP -FM.1.2.2.3 pressure (MPa) -D -T P ow valve Fl N AQ V e n by o i t p nsum n stroke o c r i r a Cuts g the retu
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationSpecifications. Model VEX Operating style Fluid Proof pressure Max. operating pressure
Power Valve Regulator Valve Series 1 Large Capacity Relief Regulator 3 port large capacity poppet exhausting regulator equipped with a relief port the same size as the connection port. Specifications Model
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationDiscontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.
Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing
More informationINSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
More informationINSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator
INSTRUCTION MANUAL CVS P37 LP Gas Reducing Regulator The CVS Controls P37 Regulator is a non-relieving, pressure reducing regulator suitable for use in LP gas applications (Natural Gas and Propane). As
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationAir Saving Valve. Pressure Valve Flow Valve
Air Saving Valve Series Series Pressure Valve Flow Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction
More informationMEGR-1912 Instruction Manual
MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationTECHNICAL DATA. Pressure Regulation 531a. April 24, 2009
April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationTECHNICAL DATA. Page 1 of 12
Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control
More informationPrecision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
More informationRegulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut
Regulator for 2 MPa RX 2 How to Order RX2 1 Regulator 1 Regulating pressure.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} Thread type Nil N F Rc(PT) NPT (PF) Port size 1 2 ccessories/options
More informationB74G - EXCELON Modular System General purpose filter/regulator
> Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory
More informationTECHNICAL DATA CAUTION
Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationR18 General purpose pressure regulators
> > Port size: / & (ISO G, PTF) > > Can be installed at any point in the compressed air system without regard to accessibility pilot regulator can be installed in the most convenient location > > Accurate
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationElectropneumatic Transducer (I/P) Installation, Operation and
Nitra NCP1 Series Electropneumatic Transducer (I/P) Installation, Operation and Maintenance Instructions Ordering Information Contents Part Number I/P Transducers Output Range Input psig bar Section Description
More informationSeries MX pressure regulators 3/
CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges
More informationFilter-Regulator-Lubricator
Filter-Regulator-Lubricator 1/2" NPT Inlet/Outlet Ports PD16.19 July, 2016 Machine Parts & Operating Instructions Save This Document and Educate All Personnel WARNING Always follow the safety instructions
More informationHow to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø
Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note
More informationAMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life
Water Separator Series AMG Can remove water droplets in compressed air. Use this product in cases where water must be avoided, but not so dry as when an air dryer is used. Through the adoption of an element
More informationOPERATING AND MAINTENANCE MANUAL
Series 4300 Engineered Performance TABLE OF CONTENTS 0 INTRODUCTION 1 1 Scope 1 2 Description 1 3 Specifications 1 0 INSTALLATION 1 1 Mounting 1 2 Piping 1 1 Connecting Process Pressure 2 2 Vent Connections
More informationLRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.
LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the
More informationMounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity
Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating
More informationEXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More informationMEGR-1627 Instruction Manual
MEGR-1627 HIGH FLOW GAS REGULATOR Instruction Manual- Look Inside For: Description Installation Remote Vent Line Installations Startup and Adjustment Shutdown Maintenance Body Maintenance Procedures Diaphragm
More informationPNEUMATIC PRESSURE CONTROLLERS
PNEUMATIC PRESSURE CONTROLLERS VARIABLE VOLUME PRESSURE CONTROLLER MODELS: V-1 R AND V-2R The 3D Variable Volume Pressure Controller is available for requirements of 0-1,000 psi and 0-6,000 psi in absolute
More informationPrecision Regulator. Series Model Regulating pressure range Port size Page
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More informationAir Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv
CAT.ES-173 A Air Saving Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction ratio (%) 3 1.1.1...3 pressure
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends
More informationNew Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A
Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator
More information1805 Series Relief Valves
Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion
More informationType S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual
Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local
More informationSpecifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style
Finger Valve SeriesVHK Large effective area: to mm 2 Small knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. Selection
More informationHand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.
http://www.pisco.co.jp VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Hand Valve Series 556 Control Open/Close for Air Supply. Release Residual
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationAS13 1F-M3 AS13 1F-M5 AS23 1F-01 AS23 1F-02
Spee Controller with One-touch Fittings Series Elbow Style, Universal Style Minimizes installation time an cost Reuces the mounting height an enables compact machinery esign. Effective area is larger than
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationHPB25 Hydraulic Paving Breaker
INSTRUCTION MANUAL HPB25 Hydraulic Paving Breaker Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com
More informationFilter-Regulator-Lubricator
Models: 10671-1/2" NPT Filter 10673-1/2" NPT Regulator 10675-1/2" NPT Lubricator 10677-1/2" NPT Filter-Regulator 10679-1/2" NPT Regulator-Lubricator 10681-1/2" NPT Filter-Regulator-Lubricator Parts Page
More informationPRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.
PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationALF400 to 900, ALT-5/-9
uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa Max. operating pressure
More information64 Series Pressure Reducing Regulators
Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,
More informationR84G - Excelon Plus Modular System Pressure regulators
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Easy to read flush mounted integrated pressure gauge as
More informationModel GP PRESSURE REDUCING VALVE Installation & Operation Manual
Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully
More informationRelated Products: Auto Drain Valve. Model/Specifications. Model
Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl
More informationBinks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)
INTRODUCTION Binks SG-2 Plus TM Pressure Cup is ideal for component spraying and industrial applications where small batch production spraying is required. The 2 qt. capacity is sufficient to complete
More informationALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data
ir line equipment Miniature eneral Purpose egulators 7, (non-repairable) 7 Full flow gauge ports Snap action knob locks pressure setting when pushed in Standard relieving models allow reduction of outlet
More informationPrecision pressure regulators LRP/LRPS
Precision pressure regulators LRP/LRPS q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More information(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)
This exhaust needle valve, which comes with silencer, controls the exhaust flow rate. The valve can be attached directly to a solenoid valve where a cylinder or like mechanism has no sufficient space around
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)
More informationSpeed control assembly model A-1
Pressure Regulation 533a 1. DESCRIPTION The Viking Speed Control Assembly provides adjustment of the opening speed of Viking Deluge Valves, and adjustment of both the opening and closing speed of Viking
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Dimension Weight Pump Pressure for 29200 Pump Pressure for 2920 Gauge for 29200 Gauge for 2920 Inlet Connection Outlet Connection Hose
More informationDescription Supply pressure Pressure range Connection Device Page max. bar bar thread
Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to
More informationPressure Relief Valve DHV 718
Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media
More informationINSTRUMENTATION VALVES
INSTRUMENTATION VALVES INSTRUMENTATION BALL VALVES INTEGRAL-BONNET NEEDLE VALVES TOGGLE VALVES (TG Series) CHECK VALVES (CHV Series: For General Industry) RELIEF VALVES (RVL/RVH Series) INSTRUMENTATION
More informationSpecifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style
Finger Valve eriesvhk Large effective area: to mm 2 mall knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. election from
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationMasoneilan* 78 Model Air Filter Regulator
GE Oil & Gas Masoneilan* 78 Model Air Filter Regulator Instruction Manual [Rev. D] GE Data Classification : Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE
More informationDS06D,G Dial Set Pressure Regulating Valve
DS06D,G Dial Set Pressure Regulating Valve PRODUCT DATA FEATURES APPLICATION Built-in, factory-calibrated outlet pressure adjustment dial. Noncorroding unitized cartridge contains all working parts and
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 46453 and 464530 Hydrostatic Test Pumps 46453 DIMENSIONS: 27 (67.5cm) L x 22 (55cm) W x 34 (85cm) H WEIGHT: 160 lbs. 73 kg PUMP: Twin piston: Positive displacement type Inlet
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationPrecision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.
Precision Regulator //3 Series Basic Type Air Operated Type Series Model Set pressure range Port size Page Series Series 3 Series 3 3 3 Series 3 Series 3.5 to MPa. to MPa. to.8 MPa /8 8.5 to MPa. to MPa.
More information1200B2 Series Service Regulators. Instruction Manual
00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available
More informationTHE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)
THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...
More informationType ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002
Installation Guide English May 2002 Type ACE97 Introduction This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact
More informationD05 Pressure Regulating Valves
D05 Pressure Regulating Valves FEATURES PRODUCT DATA Noncorroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass. Balanced seat construction
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationSeries SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100
Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationSpeed Controller Anti-spatter Series
http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Flame-Retardant Spatter-proof 422 Adopting Flame-Retardant Resin (V-). Protective Cover to Protect from Sparks.
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationMounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators
Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 36454 and 364540 Hydrostatic Test Pumps 36454 DIMENSIONS: 24 (61cm) L x 19 (48cm) W x 19.5 (50cm) H WEIGHT: 135 lbs 61.5 kg PUMP: Twin piston: Positive displacement type Inlet
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More informationLRS(H)4 Pressure-Reducing Regulator User Manual
LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered
More information