Digital Flow Switch. Series PFM7
|
|
- Ethan Barnett
- 5 years ago
- Views:
Transcription
1 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow rate control and value management of shielding gas Compatible with the mixed gas (r + CO) (Gas ratio can be selected with -X7.) Flow rate range: 0, 5, 50,00 L/min Minimum unit setting: 0.0 L/min (0. L/min when the flow rate range is 5, 50, 00 L/min.) Repeatability: ±%F.. Grease-free Flow adjustment valve is integrated. (Reduced piping and space saving) Response time: Either 50 ms, 0.5 s, s or s can be chosen. pplications Checks the operating flow rate or residual amount (of CO etc.) in a gas cylinder. 95
2 Digital display Comparison with Float Type Flow Meter With switch output and analog output Control by sensor output Visual control patter Resistant Cylinders for rc Welding Indicated value depends on the viewing angle. With switch output and analog output Without output function Clamp Cylinders Not subject to pressure variations Indicated value is the same at any installation position. (No conversion is needed.) Indicated value depends on installation position. (Conversion is required.) Can detect whether greater or less than set flow rate. The flow condition can be controlled all the time. photoelectric switch, or similar, must be prepared separately. Can only detect when float passes. Cannot detect whether greater or less than set flow rate. Gas/ir witching Valve Detection witches ON OFF ON OFF Tubing Free mounting orientation Less Flow rate Greater Less Flow rate Greater ccumulated flow display Fittings Mounting orientation is not limited. Vertical orientation only ble to confirm the total air consumption per day (Max L) ccumulated pulse output is also equipped. Not displayable Flow Control Equipment 96
3 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r + CO) Digital Flow witch eries PFM7 RoH How to Order ymbol 0 0 N0 N0 F0 F0 C4 C6 C N7 7 Piping Variations PFM7 0 C4 M Type Integrated display Rated flow range (Flow rate range) to 0 (5) L/min 0.5 to 5 (.5) L/min to 50 (5) L/min to 00 (50) L/min ( ): Fluid: CO When using argon (r), carbon dioxide (CO) and the mixed gas (r + CO), refer to page 0. Flow adjustment valve None Yes Description Rc/ Rc/4 NPT/ NPT/4 G/ G/4 ø4 (5/") One-touch fitting ø6 One-touch fitting ø (5/6") One-touch fitting ø/4" One-touch fitting Port size Flow rate range Piping entry direction L traight Bottom Different combinations of piping entry directions for and OUT side are available as made-to-order. Unit specifications M Calibration certificate None With calibration certificate The certificate is written in English and Japanese. Other languages are available as specials. Operation manual With operation manual (Japanese and English) N None Fixed I unit Note ) With unit switching function Note ) Note ) Fixed unit: Instantaneous flow rate: L/min ccumulated flow: L Note ) ince the unit for Japan is fixed to I due to new measurement law, this option is for overseas. Output specifications B C D E F G H NPN outputs PNP outputs NPN output + nalog ( to 5 V) NPN output + nalog (4 to 0 m) PNP output + nalog ( to 5 V) PNP output + nalog (4 to 0 m) NPN output + External input Note ) PNP output + External input Note ) Note ) User can select from accumulated value external reset, auto-shift and auto-shift zero. Option (Refer to page 9.) Option (Refer to page 9.) Made to Order Compatible with argon (r) and X7 carbon dioxide (CO) mixed gas (Refer to page 0.) With One-touch fittings (C4, C6, C, N7) Female thread (0, 0, N0, N0, F0, F0) traight () Bottom (L) traight () Bottom (L) Without flow adjustment valve () With flow adjustment valve () 97
4 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r + CO) Digital Flow witch Option With lead wire with connector ( m) W With lead wire with connector ( m) + Rubber cover for connector (silicon rubber) Z Without lead wire with connector eries PFM7 patter Resistant Cylinders for rc Welding Z--D Lead wire length m Z--F Z--D Lead wire length m Clamp Cylinders Option None R Bracket (For without flow adjustment valve) Z--M Mounting screw (accessory) Bracket (For with flow adjustment valve) Z--M Mounting screw (accessory) T Panel mount adapter (For without flow adjustment valve) Z--J Panel mount adapter B Panel mount adapter Gas/ir witching Valve V Panel mount adapter (For with flow adjustment valve) Piping direction: Cannot be mounted with bottom piping type. Mounting bracket Panel Detection witches Z--J Panel mount adapter B Panel mount adapter Tubing Panel Mounting bracket Each option is not assembled with the product, but shipped together. D Rail Mounting Bracket (Order eparately) Fittings Z R 4 5 tations station stations stations 4 stations 5 stations D rail (supplied by customers) Port size F0: G/4 cannot be mounted on the D rail. Flow Control Equipment 9
5 eries PFM7 pecifications For details about the Flow witch Precautions, refer to Handling Precautions for MC Products. For details about the pecific Product Precautions, refer to the Operation Manual at MC website. Model PFM70 PFM75 PFM750 PFM7 pplicable fluid Dry air, N, r, CO (ir quality grade is JI B9-,.. to.6. and IO57-,.. to.6..) Rated flow range Note ) Dry air, N, r 0. to 0 L/min 0.5 to 5 L/min to 50 L/min to 00 L/min (Flow rate range) CO 0. to 5 L/min 0.5 to.5 L/min to 5 L/min to 50 L/min Dry air, N, r 0. to 0.5 L/min 0.5 to 6. L/min to 5.5 L/min to 05 L/min Displayable range Note ) Note ) CO 0. to 5. L/min 0.5 to. L/min to 6. L/min to 5 L/min Dry air, N, r 0 to 0.5 L/min 0 to 6. L/min 0 to 5.5 L/min 0 to 05 L/min ettable range Note ) Note ) CO 0 to 5. L/min 0 to. L/min 0 to 6. L/min 0 to 5 L/min Minimum unit setting Note ) 0.0 L/min 0. L/min 0. L/min 0. L/min ccumulated pulse flow rate exchange value 0. L/pulse 0. L/pulse 0. L/pulse L/pulse Instantaneous flow rate L/min, CFM x 0 - Indication unit Note ) ccumulated flow L, ft x 0 - Linearity Display accuracy: ±%F.. (Fluid: Dry air) nalog output accuracy: ±5%F.. (Fluid: Dry air) Repeatability ±%F.. (Fluid: Dry air) nalog output accuracy: ±%F.. (Fluid: Dry air) Pressure characteristics Temperature characteristics Operating pressure range Rated pressure range Proof pressure ccumulated flow range witch output ccumulated pulse output nalog output Note 5) Note ) Hysteresis Note 6) External input Display method tatus LED s Power supply voltage Current consumption Environment Maximum load current Maximum applied voltage Internal voltage drop Response time Output protection Hysteresis mode Window comparator mode Enclosure Response time Voltage output Current output Operating fluid temperature Operating temperature range Operating humidity range Withstand voltage Insulation resistance NPN output: V or less (at 0 m) ±5%F.. (0.5 MPa reference) ±%F.. (5 to 5 C) ±5%F.. (0 to 50 C) 00 kpa to 750 kpa 70 kpa to 750 kpa Note ) When the minimum unit setting 0.0 L/min is selected for 0 L/min type, the indication upper limit will be [9.99 L/min]. When the minimum unit setting 0. L/min is selected for 00 L/min type, the indication upper limit will be [99.9 L/min]. Note ) User can select between 0.0 L/min and 0. L/min for the PFM70, and between 0. L/min and L/min for the PFM7 respectively. If the indication unit is selected to CFM, the minimum unit setting cannot be changed. t the time of shipment from the factory, the minimum unit setting is set to 0. L/min for the PFM70 and L/min for the PFM7 respectively. Note ) et to NR at the time of shipment from the factory. NR is used for standard conditions: 0 C, atm and 65%R.H. NL/min is used for normal conditions: 0 C and atm. When equipped with a unit switching function. (The I unit (L/min or L) is fixed for types with no unit switching function.) Note 4) Cleared when the power supply is turned off. Hold function can be selected. (Interval of min or 5 min can be selected). If the 5 min interval is selected, the life of the memory element (electronic part) is limited to million cycles. (If energized for 4 hours, life is calculated as 5 min x million = 5 million min = 9.5 years). Therefore, if using the hold function, calculate the memory life for your operating conditions, and use within this life. Note 5) et to.5 s (90%), can be changed to 00 ms. Note 6) et to hysteresis mode at the time of shipment from the factory. Can be changed to window comparator mode using push-buttons. Note 7) For details about wiring and thread type, refer to the Operation Manual that can be downloaded from MC website ( Note ) When using argon (r), carbon dioxide (CO) and the mixed gas (r + CO), refer to page 0. MPa Max L Note 4) NPN or PNP open collector output 0 m VDC (at NPN output) PNP output:.5 V or less (at 0 m) s (50 ms, 0.5 s, s can be selected.) hort-circuit protection NPN or PNP open collector output (ame as switch output).5 s or less (90% response) Voltage output: to 5 V Output impedance: kω Current output: 4 to 0 m Max. load impedance: 600 Ω, Min. load impedance: 50 Ω Variable Variable No-voltage input (Reed or olid state) Input 0 ms or more -digit, 7-segment LED -color display (Red/Green) Renewed cycle: 0 times/sec OUT: Lights up when output is turned ON (Green). OUT: Lights up when output is turned ON (Red). 4 VDC ±0% 55 m or less IP40 0 to 50 C (with no freezing and condensation) Operating: 0 to 50 C tored: 0 to 60 C (with no freezing and condensation) Operating, tored: 5 to 5%R.H. (with no condensation) 000 VC for minute between terminals and housing 50 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing 99
6 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r + CO) Digital Flow witch ettable Range and Rated Flow Range et the flow rate within the rated flow range. The settable rate range is the range of flow rate that can be set in the switch. The rated flow range is the range that satisfies the switch specifications (accuracy, linearity etc.). It is possible to set a value outside of the rated flow range if it is within the settable range, however, the specification is not be guaranteed. The flow range if using CO is given in brackets. When using argon (r), carbon dioxide (CO) and the mixed gas (r + CO), refer to page 0. ensor PFM70 PFM50 PFM75 PFM55 PFM750 PFM550 PFM7 PFM5 0. L/min 0. L/min Flow range 0. L/min 0.5 L/min L/min L/min 0 L/min 5 L/min 50 L/min 00 L/min 0.5 L/min 0.5 L/min L/min L/min L/min L/min 0 L/min (5 L/min) 0.5 L/min (5. L/min) 0.5 L/min (5. L/min) 5 L/min (.5 L/min) 6. L/min (. L/min) 6. L/min (. L/min) 50 L/min (5 L/min) 5.5 L/min (6. L/min) 5.5 L/min (6. L/min) eries PFM7 00 L/min (50 L/min) 05 L/min (5 L/min) 05 L/min (5 L/min) Rated flow range Displayable range ettable range In the case of the PFM5 series, the displayable and settable ranges are the same as the PFM series flow monitor. patter Resistant Cylinders for rc Welding Clamp Cylinders Gas/ir witching Valve Detection witches Piping pecifications/weight Port size Weight Part no. 0 Wetted parts material Rc / 0 Rc /4 N0 NPT / N0 NPT /4 F0 F0 G/ G/4 C4 ø4 (5/") One-touch fitting traight Without orifice: 95 g traight Without orifice: 5 g traight Without orifice: 55 g Bottom Without orifice: 05 g Bottom Without orifice: 5 g Bottom Without orifice: 65 g traight With orifice: 5 g traight With orifice: 65 g traight With orifice: 95 g Bottom With orifice: 45 g Bottom With orifice: 75 g Bottom With orifice: 05 g LCP, PBT, Brass (Electroless nickel plating), HNBR (+ Fluoro coated), FKM (+ Fluoro coated), ilicon, u, tainless steel 04 C6 ø6 One-touch fitting C6 ø (5/6") One-touch fitting N7 ø/4" One-touch fitting Tubing Fittings nalog Output Note) nalog output at maximum rated flow rate when CO is selected is [V] for the voltage output type and [m] for the current output type. Note) When using argon (r), carbon dioxide (CO) and the mixed gas (r + CO), refer to page 0. nalog output [V] 5 nalog Voltage Output ( to 5 V) Model Max. rated flow value [L/min] 0 0 Max. rated PFM70--C/E PFM75--C/E PFM750--C/E PFM7--C/E 0 (5) 5 (.5) 50 (5) 00 (50) flow value ( ): Fluid: CO nalog output [m] 0 Max. rated flow value nalog Current Output (4 to 0 m) Model PFM70--D/F PFM75--D/F PFM750--D/F PFM7--D/F ( ): Fluid: CO Max. rated flow value [L/min] 0 (5) 5 (.5) 50 (5) 00 (50) Flow Control Equipment 00
7 PFM7-X7 Digital Flow witch Made to Order pecifications Please contact MC for detailed specifications, lead times and prices. Compatible with rgon (r) and Carbon Dioxide (CO) Mixed Gas ymbol X7 The argon carbon dioxide gas ratio (r: CO) can be selected using the push-buttons from among the following: 9 :, 90 : 0, 0 : 0, 70 : 0, and 60 : 40. Dimensions are same as those of standard models. PFM 7 X7 7 Integrated display For details of How to Order, refer to page 97. Model PFM70 PFM75 PFM750 PFM7 Gas ratio r CO 9% % 90% 0% 0% 0% 70% 0% 60% 40% 9% % 90% 0% 0% 0% 70% 0% 60% 40% 9% % 90% 0% 0% 0% 70% 0% 60% 40% 9% % 90% 0% 0% 0% 70% 0% 60% 40% Rated flow range 0. to 7.0 L/min 0.5 to 5.0 L/min 0.5 to 0.0 L/min.0 to 50.0 L/min.0 to 40.0 L/min to 00 L/min to 90 L/min to 0 L/min Displayable range 0. to 7.4 L/min 0.5 to 6. L/min 0.5 to.0 L/min.0 to 5.5 L/min.0 to 4.0 L/min to 05 L/min to 95 L/min to 4 L/min ettable range 0 to 7.4 L/min 0 to 6. L/min 0 to.0 L/min 0 to 5.5 L/min 0 to 4.0 L/min 0 to 05 L/min 0 to 95 L/min 0 to 4 L/min Max. analog output Voltage (Vmax) Current (Imax).0 V 5. m 5.00 V 0.0 m 4.0 V 6. m 5.00 V 0.0 m 4.0 V 6. m 5.00 V 0.0 m 4.60 V.4 m 4.0 V 6. m Output characteristics using mixed gas nalog voltage output ( to 5 V) nalog current output (4 to 0 m) nalog output [V] 5 Vmax nalog output [m] 0 Imax When dry air selected Max. rated flow value When mixed gas selected Max. rated flow value When dry air selected Max. rated flow value When mixed gas selected Max. rated flow value 0
8 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r + CO) Digital Flow witch Dimensions PFM7-C4/C6/C/N7 OUT DC ( ) OUT DC (+) 0. 4 eries PFM7 One-touch fitting pplicable tube O.D. ø4 (5/") ø6 ø (5/6") ø/4" (mm) patter Resistant Cylinders for rc Welding Clamp Cylinders x One-touch fitting 4 PFM7-C4L/C6L/CL/N7L OUT OUT DC ( ) DC (+) (4.) (4.) x.4 OUT With rubber cover for connector Gas/ir witching Valve x.6 depth 5 Detection witches One-touch fitting pplicable tube O.D. ø4 (5/") ø6 ø (5/6") ø/4" (mm) Tubing Fittings x One-touch fitting x.4 6 OUT Flow Control Equipment x.6 depth 5 0
9 eries PFM7 Dimensions PFM7-(N)0/(N)0/F OUT DC ( ) OUT DC (+) Width across flats (4.) OUT x port size Rc /, /4 NPT /, /4 G / x.4 PFM7-(N)0L/(N)0L/F0L 4 OUT DC ( ) OUT DC (+) 0. 4 (4.) x port size Rc /, /4 NPT /, /4 G / Width across flats 7 x.4 6 OUT x.6 depth 5 0 x.6 depth 5
2-Color Display Digital Flow Switch
2-Color Display Digital Flow Switch Series Flow rate range:, 25, 5, L/min. Minimum unit setting:. L/min. (. L/min when the flow rate range is 25, 5, L/min.) Fluid Repeatability: ±%F.S. ir, N2, r, CO2 Grease-free
More information10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor
2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/EA ZSE E RoHS New IP65 ZSE E ZSE0 E0 M8 connector type E70 ZSE E E Applicable Air, Non-corrosive gas, Non-flammable gas fluid Can copy
More informationPSE Series. Remote Type Pressure Sensors/Pressure Sensor Controllers PSE550 ISE70 PS ISA3 ISA2 ISE35 PSE IS ISG ZSM1
Remote Type Pressure Sensors/Pressure Sensor Controllers PSE Series Compact Pneumatic Pressure Sensor PSE530 Pressure Sensor for General FluidsPSE560 sp.134 Low Differential Pressure Sensor sp.143 PSE550
More information1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.
3-Screen Display High-Precision Digital Pressure Switch For Air 1.0 ISE70 ISE71 MPa/1.6 MPa RoHS IP67 It is possible to change the settings while checking the measured value. Main screen Measured value
More informationCompact Pressure Switch
Compact Pressure Switch Series ZSE1 (For Vacuum)/SE1 (For Positive Pressure) For General Pneumatics Can be integrated with ZM ejector system. RoS Variable hysteresis 1 to 10% of set pressure (Variable)
More informationDigital electro-pneumatic regulators Series ER100
CATALOGUE > Release 8.2 Digital electro-pneumatic regulators Series ER100 TREATMENT > Digital electro-pneumatic regulators Series ER100 Port G1/4» Compact design» Digital display» Analog and digital input»
More informationPressure Sensor/ PSE57 /PSE300AC Series CAT.ES A. 3-Screen Display Sensor Monitor. 500 VAC <Twice that of the PSE560> Remote Type
Remote Type Pressure Sensor/ 3-Screen Display Sensor Monir RoHS IP65 Pressure Sensor for General Fluids PSE57 Series Rated pressure range 0 1 MPa 0 2 MPa 100 100 kpa 0 5 MPa 0 500 kpa 0 10 MPa Withstand
More informationMultistage Ejector Series ZL
Multistage Ejector Series. Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 5% and air consumption reduced % with 3 stage diffuser construction (ersus ø.3, one
More informationMultistage Ejector Series ZL
Multistage Ejector Series. Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 5% and air consumption reduced % with 3 stage diffuser construction (ersus ø.3, one
More informationPressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 VAC. Remote Type. Change the settings while checking the measured value.
Remote Type Pressure Sensor/ 3-Screen Display Sensor Monir RoHS IP65 Pressure Sensor for General Fluids PSE57 Series Rated pressure range 0 1 MPa 0 2 MPa 100 100 kpa 0 5 MPa 0 500 kpa 0 10 MPa Withstand
More information2/ Port G1/4
CATALOGUE > Release 8.8 > Series ER100 digital electro-pneumatic regulators Series ER100 digital electro-pneumatic regulators Port G1/4 Compact design Digital display Analog and digital input Programmable
More informationCompact Pressure Switch
Compact Pressure Switch Series 2 (For Vacuum)/ 2 (For Positive Pressure) For General Pneumatics Can be integrated with ZX or ZR ejector system. A Easy and simple wiring Connector type 77 Compact Pressure
More information(100: 1) Expanded flow range! Compact, Space saving. 2-Colour Display Digital Flow Switch Applicable fluid. Series PFMB. Air, N2
0 4 2-Colour Display Digital Flow Switch Applicable fluid Air, N2 New (200 L type only) RoHS Expanded flow range! Flow ratio Flow ratio is 0: for current PF2A. (00: ) Applicable flow range [L/min] 0.2
More informationPrecision Regulator. Series Model Regulating pressure range Port size Page
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More informationVacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV
Vacuum egulator IV0/ eries oh AJ A45 ingle ided Connections eries AX For ease of installation and panel mounting AM AM Integrated digital pressure switch for panel mounting I -A I (Made to Order) ingle
More informationElectronic relative and differential pressure switch type 616
Electronic relative and differential pressure switch type 616 Pressure range 0... 0.1 25 bar The switching points of the pressure switch type 616 can be potentiometer adjusted by the customer, or set in
More informationSeries 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB
Vacuum egulator eries -IV/ How to Order tandard connections IV C08 traight Clean series ody size Max. flow 140 L/min (N) Max. flow 240 L/min (N) L Fittings traight Connection tubing O.D. ymbol ubing O.D.
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationDPS-400 SERIES DPH-100 SERIES
745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO
More informationGas Mass Flow Meter SUS/SUS316
No. CP-SS-1809E Gas Mass Flow Meter SUS/SUS316 Overview The Gas Mass Flow Meter incorporates a thermal microflow sensor developed by zbil Corporation utilizing silicon micromachining technology. y integrating
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More informationCompressed Air Cleaning Filter Series
Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the
More informationHow to Order. Rc NPT 1/8 1/4 3/8 1/2
AWM 3 AWD 3 Mist Separator Regulator AWM2 to AWM4 Micro Mist Separator Regulator AWD2 to AWD4 3 E 3 E How to Order Mist Separator Regulator 1 2 Micro Mist Separator Regulator The AWM series is made up
More informationPower Valve: Precision Regulator. High precision, large capacity relief regulator
Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationPrecision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.
Precision Regulator //3 Series Basic Type Air Operated Type Series Model Set pressure range Port size Page Series Series 3 Series 3 3 3 Series 3 Series 3.5 to MPa. to MPa. to.8 MPa /8 8.5 to MPa. to MPa.
More informationFor Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor
Cat No AP3-KA-C Two-color digital display pressure sensor AP-3 Series Digital Display & Digital Control For Air Pressure EASY-TO-SEE 2-color display Green and red two-color LED display clearly shows abnormal
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationDigital Flow Switch. New. New. Expanded flow range! Compact, Space saving Compared with the current PF2A, 2-Colour Display. Series PFMB.
2-Colour Display Digital Flow Switch Applicable fluid Flow ratio Rated flow ratio is 10 : 1 for current PF2A. Dry air, N2 Expanded flow range! 100 : 1 New Rated flow range [l/min] 0.2 0.5 1 25 10 20 25
More informationG1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar
single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection
More informationMass Flow Meter (MFM) for gases
Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version
More informationVisualize Nitrogen Gas Consumption
Air Flow Monitor EWA2 SERIES Conforming to EMC Directive (all models) & Pressure Equipment Directive (AEWA2150/2200 only) Visualize Nitrogen Gas Consumption Small pipe size as Well as Air Consumption!
More informationSpecifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style
Finger Valve eriesvhk Large effective area: to mm 2 mall knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. election from
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationHow to Order. Finger material. Carbon steel 1 Stainless steel. Dust cover material Chloroprene rubber (CR) Fluoro rubber (FKM) Silicon rubber (Si)
Wedge Cam Operation lide Guide Air Gripper (2 inger) ø2, ø, ø2, ø2 How to Order tandard model 2 2 D N ong stroke model 2 2 D N Number of fingers 2 2 fingers Number of auto switches _ 2 D C 2 2 2 Bore size
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationSeries ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU
MULTISTAGE EJECTOR Multistage Ejector Series ZL ZX ZR ZM ZY ZH ZU ZL ZF Z ZCU acuum related New models! ZL212 large flow rate type and ZL112 with valve. 3.7-1 Multistage Ejector Series ZL112/212 Energy
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More informationMPM280 Piezoresistive OEM Pressure Sensor
MPM280 Piezoresistive OEM Pressure Sensor MPM280 Pressure Sensor (V1.2) Features Pressure range 0kPa~20kPa 70MPa; Gauge, absolute and sealed gauge; Constant current / Constant Voltages power supply; Isolated
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More information5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.
5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving, sealing,
More informationClean Speed Controller with One-touch Fitting
Clean Speed Controller with One-touch Fitting Series -FPQ/-FPG -FPG Series -FPQ Series Speed controllers for clean room use S R -FPQ: (electroless nickel plated) and -FPG: are now available as a series.
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS
DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationMPM280 Piezoresistive OEM Pressure Sensor
MPM280 Piezoresistive OEM Pressure Sensor MPM280 Pressure Sensor (V2.0) Features Pressure range 0kPa~20kPa 100MPa; Gauge, absolute and sealed gauge; Constant current / Constant Voltages power supply; Isolated
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationPROPORTIONAL PRECISION PRESSURE REGULATOR REGTRONIC SERIES
PROPORTIONL PREISION PRESSURE REGULTOR REGTRONI SERIES Proportional pressure regulators series REGTRONI have the job of precisely regulating the pressure in a system, the variables depending on the input
More informationSpecifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.
Finger Valve eriesvhk Large effective area:.0 to 7.5 mm mall knob operating force: 0. to. kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. election from
More information435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.
435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator RoHS Maximum supply pressure Set pressure range Stability 435 psi (3.0 MPa) 29 to 290 psi (0.2 to 2.0 MPa) Stepless control
More informationTerminal block. D sub-connector
Spd Series variation ol method Solenoid valve EVD-1 EVD-3 EVR EV21V EVS2 EVL MEVT Model Electro pneumatic regulator Functions include pressure and error display and direct memory. The 1-bit parallel model
More informationIRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20
Vacuum egulator New oh ingle ided Connections eries For ease of installation and panel mounting ingle sided connections Integrated digital pressure switch for panel mounting (Made to Order) Digital pressure
More informationGas Flow Monitor, Model CMG for Butane and Propane
No. CP-SS-1782E Gas Flow Monitor, Model CMG for utane and Propane Overview The CMG Gas Flow Monitor is a flowmeter for measuring the fuel flow rate of gas burners. It incorporates a thermal microflow sensor
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationSimple Set. Pressure Independent Control Valves 2 Way 1/2-2
The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control
More informationCompact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ
Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationLMU100/200 Series. Standard Specifications
Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient
More informationDimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)
Proportional damper actuator, non-spring return, Multi-Function Technology Torque min. Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) For proportional modulation of dampers in HVC systems. The is
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationRegulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,
More informationALF400 to 900, ALT-5/-9
uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationAMS 2710 PCB pressure sensor module with V output
FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric
More informationCompact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT
Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. G GS PPA Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g)
More informationSPD310/SPD360 Air Differential
SPD310/SPD360 Air Differential Pressure SPD310 / SPD360 SPD310 / SPD360 differential pressure transmitters are intended for use in air handling systems for the monitoring of air ducts, filters and fans.
More informationEXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationPRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES
PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the
More informationRegulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK
More information780S Ultra High Purity Series
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationSSR. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationALL-IN-ONE MINI THERMAL MASS FLOWMETER
INDICATION, TOTAIZATION, -POINT AARM, DC to ma AND PUSE OUTPUT BY ONE UNIT TF-T Series A-IN-ONE MINI TERMA MASS FOWMETER OUTINE TF-T MINI TERMA MASS FOWMETER is for the measurement of mass flow rate of
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationED 701 Hygenic Pressure Transmitter
ED 701 Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option
More informationSpecifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style
Finger Valve SeriesVHK Large effective area: to mm 2 Small knob operating force: 0.43 to 1.4 kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. Selection
More informationBS12N Piezoresistive OEM Pressure Sensor
BS12N Piezoresistive OEM Pressure Sensor Model: BS12N-1 Model: BS12N-2 Feature Pressure range (-0.1~60)Mpa; Pressure reference: Gauge, absolute and sealed gauge; Constant current power supply; Isolated
More informationLocator Locator-D-Lux Air-Saver G1 Air-Saver G2
170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products
More informationClimatic Independent Level Sensor LAR
1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior
More informationVPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control
VPPC, VPPC -ay proportional pressure control valve, > > Nominal diameter,, flange version G/ > > Visual function display (optional) > > Compact and lighteight design > > Field bus capable as part of a
More informationBS12 Piezoresistive OEM Pressure Sensor
BS12 Piezoresistive OEM Pressure Sensor Feature Pressure range (-0.1~60)Mpa; Pressure reference: Gauge, absolute and sealed gauge; Constant current power supply; Isolated construction to measure various
More informationDifferential Pressure Transmiter
Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;
More informationM9N. Nil. s n. Type of auto switch. Refer to the table below for auto switch part numbers.
eries XP/XP ir slide table ø, ø1, ø12, ø1 ow to Order lean series 11 acuum suction type 11 XP 12 1 9N 22 XP 12 1 9N opper, fluorine and silicon-free + low particle generation 22 acuum suction type ore
More informationRelative and differential pressure transmitter type 692
Relative and differential pressure transmitter type 692 Pressure range 0... 0.1 25 bar Type 692 pressure transmitters have a unique, well proven ceramic technolgy. There are variety of pressure and electrical
More informationInductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm
Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated
More informationSSL. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationBSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.
1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10
More informationVariable Area Flow Meters
PDF Published May, 04 Variable Area Flow Meters Chemline F Series Variable Area Flow Meters are ideal for plastic piping. They provide a combination of accurate visual flow rate measurement and clear flow
More informationInstallation and Operation Manual
Manual Static pressure transducer with controller Differential static pressure transducer with analog output and optional PI control mode Large diaphragm element with differential transformer Transducer
More informationSingle and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm
> Series CGPT self-centering parallel grippers with T-guide Series CGPT self-centering parallel grippers with T-guide Single and double acting, magnetic, self-centering Bores: ø 6, 20, 25, 32, 40 mm New
More information